MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)
|
|
- Jessica Holland
- 6 years ago
- Views:
Transcription
1 MX Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system or from a thermostat, for control of HVAC applications. The actuators are designed to be used in both damper and valve control applications. Typical applications include air handling units, unit ventilators, fan coil units, VAV terminals, control dampers, inlet guide vanes, and linked valve assemblies. Use the following guide to select actuators for damper applications. Refer to the Applicable Literature table for valve literature. DuraDrive Series Actuator (Includes Accessories) MX MX40-704X MX40-715X MX40-707X MX40-634X MX40-717X MX MX DuraDrive actuators conform to the following agency listings. For exceptions see Actuator Selection Chart. Printed in U.S.A F
2 Applicable Literature F-Number Description Audience Purpose F F F F F F F F F F F F F F F F Product Warranty MF , MS DuraDrive Series 35 lb-in. n-spring Return Direct Coupled Actuator Installation Instructions MF DuraDrive Series n-spring Return Direct Coupled Actuator General Instructions MS40-634X DuraDrive Series n-spring Return Direct Coupled Actuator General Instructions MF , MF DuraDrive Series n-spring Return Direct Coupled Actuator General Instructions MS , MS DuraDrive Series n-spring Return Direct Coupled Actuator General Instructions MA40-717X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MS40-717X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MF DuraDrive Series Spring Return Direct Coupled Actuator General instructions MF40-7XX3, MF40-7XX3-50X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MA40-7XX3, MA40-7XX3-50X, MA40-7XXX, MA40-7XXX-50X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MS40-7XX3, MS40-7XX3-50X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MA40-XXXX-2XX, MF40-XXXX-2XX, MS40-XXXX-2XX Series Actuator/Linkage Assemblies General Instructions VX-2000 Series Ball Valve Assembly Installation Instructions VX-2000, VX-7000 Series Ball and Globe Linked Valve Assemblies VB-2000 Series Valve/Linkage Assemblies MX40-7XXX, MX40-6XXX Series Actuator/Linkage Assemblies Selection Guide MX-6043 Series n-spring Return 35 lb-in. DuraDrive Actuators Specification Data Sheet VX-2000, VX-7000, VB-2000, MX40-7XXX, and MX40-6XXX Series Ball and Globe Linked Valve Assemblies, Valve/Linkage Assemblies, and Actuator/Linkage Assemblies Cross-Reference Guide F Valve Selection Chart Water F Valve Selection Chart Steam (two-way valves only) F CA-28 Control Valve Sizing F EN-205 Water System Guidelines DuraDrive actuators are covered by a five year warranty. Sales Personnel Application Engineers Installers Service Personnel Start-up Technicians Sales Personnel Application Engineers Sales Personnel Application Engineers Application Engineers Installers Service Personnel Start-up Technicians Describes the actuator s features, specifications, and possible applications. Provides step-by-step mounting instructions. Describes the globe valve actuator/linkage assembly s features, specifications, and possible applications. Provides step-by-step mounting instructions. Describes the actuator/linkage/ball valve assembly s features, specifications, and possible applications. Provides step-by-step mounting instructions. Provides part number cross referencing of phased out globe and ball valve assemblies with the new Invensys Building Systems direct-coupled actuators. Describes features and specifications of the MX-6043 series actuators. Provides part number cross referencing of phased-out devices with the new Invensys Building Systems Actuator/Linkage Assemblies, and Ball and Globe LInked Valve Assemblies. Provides charts, equations, and diagrams to assist in the configuration of valve system applications. TOOL-150, valve sizing slide rule may be purchased separately. Describes Invensys Building Systems approved water treatment practices. 2
3 Using this Selection Guide This selection guide contains the following sections: Actuator Part Numbering System This section explains the DuraDrive actuator part numbering system. Actuator Selection Chart Use this chart as a quick reference guide. Refer to Actuator Selection section for specifications data, as well as mounting dimensions. Actuator Accessories Chart Use this section to choose the appropriate accessories for the selected actuator. Actuator Specifications and Mounting Dimensions Use this section to choose the appropriate actuator for the application. This section includes actuator specifications data, as well as mounting dimensions. Damper Actuator Cross-Reference Refer to this section for actuator replacement data. 3
4 Actuator Part Numbering System M X X XX X - X X X 1 Control Signal Type A = Two Position F = Floating S = Proportional Fail Return Action 6 = n-spring Return 7 = Spring-Return Torque Rating 04 = 4 N-m (35 lb-in.) 07 = 7 N-m (60 lb-in.) 08 = 8 N-m (70 lb-in.) 15 = 15 N-m (133 lb-in.) 17 = 17 N-m (150 lb-in.) 34 = 34 N-m (300 lb-in.) Supply Voltage 0 = 120 Vac 1 = 230/240 Vac 3 = 24 Vac Auxiliary Switch 501 = One Switch 502 = Two Switches 1 Consult the Actuator Selection Chart and the Actuator Accessories Chart for available models. 4
5 Actuator Selection Chart Spring-Return Actuators Table-1 MA40-704X, MA40-707X, and MA40-715X Series Spring-Return Actuators. Power Input Part Numbers Running Holding Voltage 50 Hz 60 Hz 50 Hz 60 Hz VA W VA W W W MA MA Vac ± 20% MA MA Vac ± 10% MA MA (page 16) 230 Vac ± 10% MF c 24 Vac ± 20% MF c MS c MS c 24 Vac ± 20% MA MA Vac ± 20% MA MA Vac ± 10% MA MA (page 18) 230 Vac ± 10% MF MF Vac ± 20% MS MS Vac ± 20% MA MA Vac ± 20% MA MA Vac ± 10% MA MA (page 20) 230 Vac ± 10% MF MF Vac ± 20% MS MS Vac ± 20% a De-rating required for spring return actuators at low temperatures. b One adjustable from 0 to 95 rotation (0 to 1 scale). c With plenum-rated cable. d One adjustable from 25 to 85 rotation and one set to 5 fixed. SPDT Auxiliary Switches One b One b One b One b One b Two d Two d Two d Two d Two d Two d Two d Two d Two d Two d Approximate Timing in 70 F (21 C) with Load Powered Spring Return <50 <26 <50 <26 <50 <26 <130 <25 <80 <40 <195 <30 <195 <30 Output Torque Rating lb.-in. (N-m) Min. a Max. Stall 35 (4) 120 (14) 60 (7) 160 (18) <190 < (15) 300 (34) 5
6 Table-2 MA40-717X Series Spring-Return Actuators. MA Part Numbers Voltage n-spring Return Actuators Power 50/60 Hz Watts SPDT Auxiliary Switches 24 Vac ± 20% MA b 120 Vac ± 10% MA Vac ± 10% MF (page 22) 24 Vac ± 20% MS Vac ± 20% MS b 120 Vac ± 10% MS Vac ± 10% a De-rating required for spring return actuators at low temperatures. b The CE directive is not applicable to this model. Approximate Timing in 70 F (21 C) with Load VA Spring Powered Running Holding Return Min. a Output Torque Rating lb.-in. (N-m) Max. Stall < (17) 450 (51) Table-3 n-spring Return Actuators. Part Numbers Voltage Power 50/60 Hz Watts VA SPDT Auxiliary Switches MF a 24 Vac +20/-15% MF ab 24 Vac +20/-15% Two MF ac 24 Vac +20/-15% MS a (page 10) 24 Vac +20/-15% MS ab 24 Vac +20/-15% Two MS ad 24 Vac +20/-15% MS ae 24 Vac +20/-15% Two MF Vac ± 20% (page 12) MS Vac ± 20% MF Vac ± 20% (page 14) MS Vac ± 20% MF Vac ± 20% MS (page 24) 24 Vac ± 20% MS f 120 Vac ± 10% MS Vac ± 10% a Equipped with plenum-rated cable. b Equipped with two built-in auxiliary switches. c Equipped with 1K feedback potentiometer. d Equipped with adjustable start-span. e Equipped with adjustable start-span and two auxiliary switches. f The CE directive is not applicable to this model. Approximate Timing in 70 F (21 C) with Load Output Torque Rating lb.-in. (N-m) Running Holding Min. Max. Stall Hz Hz < (4) 60 (7) 70 (8) 114 (13) 133 (15) 187 (21) < (34) 600 (68) 6
7 Actuator Accessories Chart AM-671 AM-672 AM-673 AM-674 AM-675 AM-690 AM-691 AM-676 AM-689 AM-686 AM-687 AM-692 AM-693 Figure-1 AM-703 AM-704 Part Numbers Description MA40-704X Series MF MS Spring Return Actuators MA40-707X Series MF MS MA40-715X Series MF MS MA40-717X Series MF MS MF MS MF n-spring Return Actuators AM-671 abcd X X X X AM-672 abcd Mounting Bracket X X X X AM-673 c X X X X X X AM-674 Weather X X X X X X X X X X X X X X Shield & AM-675 Base X X X X X X AM-676 Shaft Extension X X X X X X X X X X X X X X AM-686 Position Indicator X X X X AM-687 V-clamp X X X X AM-689 Rotation Limiter X X X X AM-690 X X X X Crank Arm AM-691 X X X X AM-692 V-bolt X X X X AM-693 ef AM-703 AM-704 Crank Arm Kit Span Adjustment Modulation Interface X X X X X X X X X X X X X X X X X X MS MF MS MF MS40-634X Series General Instructions Document F F F F a b c d e f AM-693 crank arm kit required. Cannot be used with MX40-634X or MX40-717X series actuators. Drill appropriate mounting holes where needed. The large "C"-shaped clamps included in AM-693 crank arm kit are required for mounting the actuator. Drill appropriate mounting holes where needed. Use the self-tapping screws and flat washers provided in kit to mount actuator. AM-692 V-bolt kit required. 7
8 % AM-708 AM-709 AM-705 AM-706 AM-707 AM-710 AM-711 AM-712 AM AM-720 AM-721 AM-722 AM-723 AM-714 AM-715 Figure-2 Part Numbers Description MA40-704X Series MF MS Spring Return Actuators MA40-707X Series MF MS MA40-715X Series MF MS MA40-717X Series MF MS MF MS n-spring Return Actuators MF MS MF MS MF MS40-634X Series General Instructions Document AM-705 X X X X X X X Positioner AM-706 X X X X X X X AM-707 Digital Indication X X X X X X X F AM Ohm Resistor X X X X X Position AM-709 Indicator & X X Stroke Limiter AM-710 V-clamp X X F AM-711 Crank Arm X X AM-712 a Adaptor Kit X X AM-713 a Bracket X X AM-714 Weather Shield X X X X X X X b X b X b X b F AM-715 a Crank Arm Adaptor Kit X X F AM-720 X X X X AM-721 X X X X Auxiliary Switch F AM-722 X X X X AM-723 X X X X a b Use the self-tapping screws and flat washers provided in kit to mount actuator. Cannot be used with auxiliary switch mounted. 8
9 AM-727 AM-724 AM-725 AM-726 AM-728 AM-751 AM-752 AM-753 AM-754 AM-755 AM-756 Figure-3 Part Numbers Description MA40-704X Series MF MS Spring Return Actuators MA40-707X Series MF MS MA40-715X Series MF MS MA40-717X Series MF MS MF MS n-spring Return Actuators MF MS MF MS MF MS40-634X Series General Instructions Document AM-724 2K Ohm Potentiometer X X X X F AM Ohm Potentiometer X X X X AM-726 X Crank Arm Adaptor AM-727 X F AM-728 a Conduit Adaptor X AM-751 Anti-rotation X X X X AM-752 Bracket X X X X AM-753 Mounting Clamp X X X X F AM-754 X X X X AM-755 Manual Override Crank X X AM-756 Metric Conduit Adaptor X X X X X X X X X X F TF Sealtight Conduit X X X X TF Connector X X X X TF-5521 Pipe Plug X X X X a Cannot be used when creating a linked valve/actuator assembly. 9
10 Actuator Specifications and Mounting Dimensions MF and MS Actuators For non-spring return applications requiring floating or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round, square, or hexagonal damper shaft Rated at 35 lb-in. (4 N-m) torque, minimum Does not require any limit switches Manual override allows positioning for installation and manual operation MF provides floating point control (3-position) MS provides proportional control compatible with 0 to 10 Vdc Models available with: independently adjustable dual auxiliary switches; adjustable start point (offset) and span Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MF Floating three-position control, 24 Vac. MS Proportional, 0 to 10 Vdc; input resistance 100KΩ. Control signal adjustment available with MS and MS : Start point (offset) Between 0 and 5 Vdc (factory setting = 0 Vdc) Span 2 to 30 Vdc Power Requirements All 24 Vac circuits are Class 2. Part Numbers Power 50/60 Hz Voltage Running VA Holding VA Watts MF Vac +20/-15% MS Vac +20/-15% Connections Motor Type Outputs Electrical 3 ft. (0.9 m) long, 18 AWG leads, plenum-rated. Synchronous Position output signal Feedback potentiometer available with MF : 0 to 1000Ω < 10 ma Output voltage: 0 to 10 Vdc Maximum output current: 1mA Dual auxiliary switches available with MF and MS Contact rating: 4 A resistive, 2 A inductive Voltage: 24 Vac Switching hysteresis: 3 Switch Range: Switch A 0 to 90 range in 5 intervals Recommended range usage 0 to 45 Factory setting 5 Switch B 0 to 90 range in 5 intervals Recommended range usage 45 to 90 Factory setting 85 Timing: 108 Sec. at 50 Hz 90 Sec. at 60 Hz te: The position markings on the actuator label indicate shaft position as a percentage of full rotation. That is, ".2" means 20% of full rotation, ".4" means 40%, and so on, up to "1," which means 100%, or 90. For example, ".6" indicates 60% of full rotation, or
11 Actuator Specifications Mechanical Output torque rating: 35 lb-in. (4 N-m) minimum; 60 lb-in. (7 N-m) maximum. Stroke: rmal angle of rotation is 90, limited to a maximum of 95. Field adjustable to limit travel on either end of stroke. Position indicator: Adjustable pointer is provided for position indication. See the te in "Switch Range." Output shaft setscrew: tightening torque 55 to 60 lb-in. (6.3 to 6.8 N-m). minal Damper Area: Up to 8 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area. Actuator sizing, however, should be done in accordance with damper manufacturer s specifications Environment Temperature Limits Shipping and storage: -25 to 140 F (-32 to 60 C) ambient. Operating: -25 to 130 F (-32 to 55 C) ambient. Humidity 5 to 95% RH, non-condensing. Locations NEMA Type 2. Agency Listings UL UL-873, Underwriters Laboratories. European Community EMC Directive (89/336/EEC). Emissions (EN ). Immunity (EN ). CSA Canadian Standards C Accessories AM-726 Rotary-to-Linear Bracket AM-727 Rotary-to-Linear Crank Arm AM-728 Conduit Adapter 2-3/8 (60) 15/16 (24) 13/16 (21) 7/16 (11) 2-3/4 (70) 5/32 (4) /16 (137) 3-7/16 (87) Figure-4 MF and MS Mounting Dimensions. 11
12 MF and MS Actuators For non-spring return applications requiring floating or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 70 lb-in (8 N-m) torque rating Does not require any limit switches Manual override to allow positioning for installation and manual operation MF provides floating point control (drive open-hold-drive closed) MS provides proportional control compatible with 0 to 10 Vdc or 0 to 20 madc Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MF SPDT floating control 24 Vac. MS Proportional, 0 to 10 Vdc or 0 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. Connections Motor Type Outputs Electrical Mechanical Environment Temperature Limits Humidity Locations Agency Listings UL Part Numbers Power 50/60 Hz Voltage Running VA Holding VA MF Vac ±20% MS Vac ±20% ft. (91 cm) long appliance cables, 18 AWG color coded leads. Stepper Timing: Approximate timing is 120 seconds. Output torque rating: 70 lb-in. (8 N-m) minimum, 140 lb-in. (16 N-m) maximum. Stroke: Angle of rotation is limited to a maximum of 90, field adjustable to limit travel on either end of stroke. Position indicator: Adjustable pointer is provided for position indication. Damper Shaft Clamp: Direct coupled using a through hole output hub. minal Damper Area: Up to 18 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area. Actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: 20 to 131 F (-7 to 55 C). 5 to 95% RH, non-condensing. NEMA 2 (IEC IP54). Actuator not in compliance if mounted upside down. UL873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C
13 3-25/64 (84) 1-19/64 (32) 2-13/16 (70) 1.25/64 (36) 2-13/64 (56) 1-19/32 (40) 3-45/64 (94) 6-13/16 (173) Figure-5 MF and MS Mounting Dimensions. 13
14 MF and MS Actuators For non-spring return applications requiring floating or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 133 lb-in (15 N-m) torque rating Does not require any limit switches Manual override to allow positioning for installation and manual operation MF provides floating point control (drive open-hold-drive closed) MS provides proportional control compatible with 0 to 10 Vdc or 0 to 20 madc Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MF SPDT floating control 24 Vac. MS Proportional, 0 to 10 Vdc or 0 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. Connections Motor Type Outputs Electrical Mechanical Environment Temperature Limits Humidity Locations Agency Listings UL Part Numbers Power 50/60 Hz Voltage Running VA Holding VA MF Vac ±20% MS Vac ±20% ft. (91 cm) long appliance cables, 18 AWG color coded leads. Stepper Timing: Approximate timing is 120 seconds. Output torque rating: 133 lb-in. (15 N-m) minimum, 187 lb-in. (21 N-m) maximum. Stroke: Angle of rotation is limited to a maximum of 90, field adjustable to limit travel on either end of stroke. Position indicator: Adjustable pointer with a scale numbered from 0 to 10, provided for position indication. Damper Shaft Clamp: Direct coupled using a through hole output hub. minal Damper Area: Up to 35 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: 20 to 131 F (-7 to 55 C). 5 to 95% RH, non-condensing. NEMA 2 (IEC IP54). Actuator not in compliance if mounted upside down. UL873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C
15 3-25/64 (84) 1-19/64 (32) 2-13/16 (70) 1.25/64 (36) 2-13/64 (56) 1-19/32 (40) 3-45/64 (94) 6-13/16 (173) Figure-6 MF and MS Mounting Dimensions. 15
16 MA40-704X, MF , and MS Series Actuators For spring return applications requiring floating, two-position, or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 35 lb-in (4 N-m) torque rating Overload protection throughout rotation Optional built-in auxiliary switches True mechanical clockwise or counterclockwise spring return operation for reliable, positive close-off in airtight applications Visual position indicator Direct acting or reverse acting control mode available on proportional models Rotation limiting available Rugged die-cast housing for NEMA 2/IP54 rating Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MA40-704X and MA40-704X-501 On-off. SPST control contacts or Triacs (500 ma rated). MF and MF Floating point control, 24Vac. MS and MS Spring return, proportional, 2 to 10 Vdc or 4 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers MA and MA MS and MS MF and MF MA and MA MA and MA Voltage 50/60 Hz Running Holding 50 Hz 60 Hz 50 Hz 60 Hz VA W VA W W W 24 Vac ± 20% Vac ± 20% Vac ± 20% Vac ± 10% Vac ± 10% Connections Motor Type Outputs Electrical MA40-704X and MA40-704X ft. (91 cm) long, appliance cables, 1/2 in. conduit connector. For M20 Metric conduit, use AM-756 adaptor. MF and MF , MS and MS ft. (91 cm) long, plenum-rated cables, 1/2 in. conduit connector. For M20 Metric conduit, use AM-756 adaptor. MA40-704X - Brush. MF , MS Brushless DC Control Mode: Switch provided for selection of direct acting or reverse acting control mode on proportional models. Timing: Approximate timing for MA40-704X series is 50 seconds. Approximate timing for MF series or M series is 130 seconds. 16
17 Actuator Specifications Electrical (continued) Mechanical Environment Temperature Limits Humidity Locations Agency Listings UL One auxiliary switch available with MX , SPDT 6A 24 Vac, adjustable 0 to 95 (0 to 1 scale). UL Listed, switch meets VDE requirements for 6 (1.5)A, 24 Vac. One auxiliary switch available with MA or MA , SPDT 6A 250 Vac, adjustable 0 to 95 (0 to 1 scale). UL Listed, switch meets VDE requirements for 6 (1.5)A, 250 Vac. Position Feedback Voltage AO : 2 to 10 Vdc (maximum 0.5 ma) output signal for position feedback or operation of up to four slave actuators. Output Torque Rating: 35 lb-in. (4 N-m) minimum, 120 lb-in. (14 N-m) maximum. Stroke: Rotation is limited to 95 ± 5 maximum, adjustable from 40 to 95 with a mechanical stop. Position Indicator: Visual indicator, 0 to 1 (0 is the spring-return position). Direction of Rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 3/4" in diameter and 1/2" square. minal Damper Area: Up to 8 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: -22 to 122 F (-30 to 50 C). 5 to 95% RH, non-condensing. NEMA 2 (IEC IP54). UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act /64 (172) 6-13/64 (157) 13/32 (10) 1 (25) 4 (103) 2 (50) 3-5/32 (80) 3 Holes for #10-24 Screws 3-21/32 (93) 4-57/64 (125) 47/64 (19) 49/64 (19) 2-13/32 (61) 3-1/2 (89) Dimensions shown are in inches (mm). 1/4 (6.4) Figure-7 MX40-704X Series Mounting Dimensions. 17
18 MA40-707X, MF , and MS Series Actuators For spring return applications requiring floating, two-position, or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 60 lb-in (7 N-m) torque rating Overload protection throughout rotation Optional built-in auxiliary switches Provides true mechanical clockwise or counterclockwise spring return operation for reliable positive close-off in airtight applications Visual position indication Direct acting or reverse acting control mode available on proportional models Rotation limiting available Rugged die-cast housing for NEMA 2/IP54 rating Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MA40-707X and MA40-707X-502 On-off. SPST control contacts or Triacs (500 ma rated). MF and MF Floating point control, 24Vac. MS and MS Spring return, proportional, 2 to 10 Vdc or 4 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers MA and MA MS and MS MF and MF MA and MA MA and MA Voltage 50/60 Hz Running Holding 50 Hz 60 Hz 50 Hz 60 Hz VA W VA W W W 24 Vac ± 20% Vac ± 20% Vac ± 20% Vac ± 10% Vac ± 10% Connections 3 ft. (91 cm) long, appliance cables, 1/2 in. conduit connectors. For M20 Metric conduit, use AM-756 adaptor. Motor Type MA40-707X Brush. MF , MS Brushless DC. Outputs Electrical Control Mode: Switch provided for selection of direct acting or reverse acting control mode on proportional models. Timing: Approximate timing for MA40-707X series is 80 seconds. Approximate timing for MF series or M series is 195 seconds. Two auxiliary switches available with MX or MX , SPDT 7A 250 Vac, one 5 and one adjustable 0 to 90. UL Listed, meets VDE requirements for 7 (2.5)A, 250 Vac. Two auxiliary switches available with MX , SPDT 7A 24 Vac, one 5 and one adjustable 0 to 90. UL listed, switches meet VDE requirements for 6 (1.5)A, 24 Vac. 18
19 Actuator Specifications (Continued) Electrical (continued) Mechanical Environment Temperature Limits Position Feedback Voltage AO, 2 to 10 Vdc (maximum 0.5 ma) output signal for position feedback or operation of up to four slave actuators. Output Torque Rating: 60 lb-in. (7 N-m) minimum, 160 lb-in. (18 N-m) maximum. Stroke: Rotation is limited to 95 ± 5 maximum, adjustable from 30 to 95 with AM-689 rotation limiter. Position Indicator: Pointer and (-5 to 90 ) scale are provided for position indication (-5 is the normal, or spring-return, position). Direction of Rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 1.05" in diameter and 5/8" square. minal Damper Area: Up to 15 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Humidity Locations Agency Listings UL Operating: -22 to 122 F (-30 to 50 C). 5 to 95% RH, non-condensing. NEMA 1. NEMA 2 (IEC IP54) with conduit connector in the down position. UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act /2 (89) 2-25/64 (61) 4 (103) 2-7/64 (53) 10-1/2 (267) 7-1/2 (191) 6 Holes for #10-24 Screws Dimensions shown are in inches (mm). Figure-8 MX40-707X Series Mounting Dimensions. 19
20 MA40-715X, MF , and MS Series Actuators For spring return applications requiring floating, two-position, or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 133 lb-in (15 N-m) torque rating Overload protection throughout rotation Optional built-in auxiliary switches True mechanical clockwise or counterclockwise spring return operation for reliable positive close-off in airtight applications Visual position indicator Direct acting or reverse acting control mode available on proportional models Rotation limiting available Rugged die-cast housings for NEMA 2/IP54 Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MA40-715X and MA40-715X-502 On-off. SPST control contacts or Triacs (500 ma rated). MF and MF Floating point control 24 Vac. MS and MS Proportional, 2 to 10 Vdc or 4 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers MA and MA MS and MS MF and MF MA and MA MA and MA Voltage 50/60 Hz Running Holding 50 Hz 60 Hz 50 Hz 60 Hz VA W VA W W W 24 Vac ± 20% Vac ± 20% Vac ± 20% Vac ± 10% Vac ± 10% Connections Motor Type Outputs Electrical 3 ft. (91 cm) long, appliance cable, 1/2 in. conduit connectors. For M20 Metric conduit, use AM-756 adaptor. MA40-715X, MF , MS Brushless DC. Control Mode: Switch provided for selection of direct acting or reverse acting control mode on proportional models. Timing: Approximate timing is 190 seconds. Two auxiliary switches available with MX or MX , SPDT 7A 250 Vac, one 5 and one adjustable 0 to 90. UL Listed, meets VDE requirements for 7 (2.5)A, 250 Vac. Two auxiliary switches available with MX , SPDT 7A 24 Vac, one 5 and one adjustable 0 to 90. UL listed, switches meet VDE requirements for 6 (1.5)A, 24 Vac. 20
21 Actuator Specifications (Continued) Electrical (continued Mechanical Environment Temperature Limits Position Feedback Voltage AO, 2 to 10 Vdc (maximum 0.5 ma) output signal for position feedback or operation of up to four slave actuators. Output Torque Rating: 133 lb-in. (15 N-m) minimum, 300 lb-in. (34 N-m) maximum. Stroke: Rotation is limited to 95 ± 5 maximum, adjustable from 30 to 95 with AM-689 rotation limiter. Position Indicator: Pointer and (-5 to 90 ) scale are provided for position indication (-5 is the normal, or spring-return, position). Direction of Rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 1.05" in diameter and 5/8" square. minal Damper Area: Up to 35 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Humidity Locations Agency Listings UL Operating: -22 to 122 F (-30 to 50 C) 5 to 95% RH, non-condensing. NEMA 1. NEMA 2 (IEC IP54) with conduit connector in the down position. UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act /2 (89) 2-25/64 (61) 4 (103) 2-7/64 (53) 10-1/2 (267) 7-1/2 (191) 6 Holes for #10-24 Screws Dimensions shown are in inches (mm). Figure-9 MX40-715X Series Mounting Dimensions. 21
22 MA40-717X, MF , and MS40-717X Series Actuators For spring return applications requiring floating, two-position, or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 150 lb-in (17 N-m) torque rating Overload protection throughout rotation Oil immersed gear train provides continuous lubrication NEMA 4 housing (IEC IP56) Automatic current sensing motor control provides extended reliability and repeatable timing Provides true mechanical clockwise or counterclockwise spring return operation for reliable positive close-off in airtight applications MA40-717X models provide on-off control MF models provide floating point control (drive open-hold-drive closed) MS40-717X models provide proportional control compatible with 2 to 10 Vdc or 4 to 20 madc with integral resistor Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal Power Requirements MA40-717X Two wire, SPST or Triacs. MF SPDT floating control output, Triacs (500 ma rated), or 2 SPST contacts. MS40-717X proportional, 2 to 10 Vdc or 4 to 20 madc with integral 500 Ohm resistor. All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers Power 50/60 Hz Voltage Running VA Holding VA Watts MA Vac ±20% MS Vac ±20% MF Vac ±20% MA Vac ±10% MS Vac ±10% MA Vac ±10% MS Vac ±10% Impedance Connections Motor Type 2 to 10 Vdc, 80KΩ. 4 to 20 madc, 500Ω. (MS40-717X models only) 24 inch (61 cm) long appliance cables, 18 AWG color coded leads with 1/2 in. conduit connector. For M20 Metric conduit, use AM-756 adaptor. Brushless DC 22
23 Actuator Specifications (Continued) Outputs Electrical Stroke: Electronically limited to 93 ±1. Timing: Approximate timing is 145 seconds. Mechanical Output Torque Rating: 150 lb-in. (17 N-m) minimum, 450 lb-in. (51 N-m) maximum. Position Indicator: Pointer and scale are provided for position indication (0 is the normal, or spring-return, position). Direction of Rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 1.05" in diameter and 5/8" square. minal Damper Area: Up to 38 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Environment Temperature Limits Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: -25 to 140 F (-32 to 60 C). Humidity 5 to 95% RH, non-condensing. Locations NEMA 1. NEMA 4 (IEC IP 56) with customer supplied water tight conduit connectors. Agency Listings UL UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act R 4 (102) 1.27/64 (36) 10-27/32 (275) 4 (102) Figure-10 MX40-717X Series Mounting Dimensions. 23
24 MF and MS40-634X Series Actuators For non-spring return applications requiring floating or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 300 lb-in (34 N-m) torque rating Overload protection throughout rotation Oil immersed gear train provides continuous lubrication NEMA 4 housing (IEC IP56) Manual override to allow positioning for installation and manual operation Automatic current sensing motor control provides extended reliability and repeatable timing MF models provide floating point control (drive open-hold-drive closed) MS40-634X models provide proportional control compatible with 2 to 10 Vdc or 4 to 20 madc with integral resistor Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal 24 MF SPDT floating control output, Triacs (500 ma rated), or 2 SPST contacts. MS40-634X proportional, 2 to 10 Vdc or 4 to 20 madc with integral 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers Power 50/60 Hz Voltage Running VA Holding VA Watts MS Vac ±20% MS Vac ±10% MS Vac ±10% MF Vac ±20% Connections 24 inch (61 cm) long appliance cables, 1/2 in. conduit connector. For M20 Metric conduit, use AM-756 adaptor. Motor Type Brushless DC Outputs Electrical Stroke: Electronically limited to 93 ±1. Timing: Approximate timing is 145 seconds. Mechanical Output torque rating: 300 lb-in. (34 N-m) minimum, 600 lb-in. (64 N-m) maximum. Position indicator: Pointer and scale are provided for position indication). Direction of rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 1.05" in diameter and 5/8" square. minal Damper Area: Up to 75 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Manual Override: Activated by the manual override crank. Environment Temperature Limits Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: -25 to 140 F (-32 to 60 C). Humidity 5 to 95% RH, non-condensing. Locations NEMA 1. NEMA 4 (IEC IP56) with customer supplied water tight conduit connectors.
25 Actuator Specifications (Continued) Agency Listings UL UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act R 4 (102) 1.27/64 (36) 10-27/32 (275) 4 (102) Figure-11 MX40-634X Series Mounting Dimensions. 25
26 Damper Actuator Cross Reference Invensys Building Systems assumes no responsibility for guaranteeing the acceptability of any suggested replacement in this section. The emphasis has been placed on providing a replacement actuator of the same specifications wherever possible. The user must determine the acceptability of the substitution by reviewing the actuator specifications. The cross reference tables list Invensys Building Systems Direct-Coupled Actuators which may replace obsolete SEC and Belimo devices. The tables list two-position, floating, and proportional actuators. The devices to be replaced are listed alphanumerically in the left-hand column, with the suggested Invensys replacement in the center column. The replacement actuators in this list represent what we believe are equivalent units. SEC to Invensys Actuators SEC P/N Invensys P/N Description MA Vac 35 lb-in. (2-position) MA Vac 35 lb-in. w/aux switch (2-position) MA Vac 60 lb-in. (2-position) MA Vac 60 lb-in. w/aux switch (2-position) MA Vac 150 lb-in. (2-position) MA Vac 150 lb-in. (2-position) MA Vac 150 lb-in. (2-position) MF Vac 60 lb-in. (floating) MF Vac 60 lb-in. w/aux switch (floating) MF Vac 133 lb-in. (floating) MF Vac 133 lb-in. w/aux switch (floating) MF Vac 150 lb-in. (floating) MS Vac 60 lb-in. w/aux switch (proportional) MS Vac 133 lb-in. w/aux switch (proportional) MS Vac 150 lb-in. (proportional) MS Vac 150 lb-in. (proportional) MS Vac 150 lb-in. (proportional) MS Vac 300 lb-in. NSR (proportional) MS Vac 300 lb-in. NSR (proportional) MA-7101 MA Vac 35 lb-in.s (2-position) MA MA Vac 35 lb-in.s w/aux switch (2-position) MA-7103 MA Vac 35 lb-in. (2-position) MA MA Vac 35 lb-in. w/aux switch (2-position) MA-7201 MA Vac 60 lb-in. (2-position) MA MA Vac 60 lb-in. w/aux switch (2-position) MA-7203 MA Vac 60 lb-in. (2-position) MA MA Vac 60 lb-in. w/aux switch (2-position) MA-7501 MA Vac 133 lb-in. (2-position) MA MA Vac 133 lb-in. w/aux switch (2-position) MA-7503 MA Vac 133 lb-in. (2-position) MA MA Vac 133 lb-in. w/aux switch (2-position) MA-7505 MA Vac 133 lb-in. (2-position) MA MA Vac 133 lb-in. w/aux switch (2-position) MF-6103 MF Vac 35 lb-in. NSR (floating) MF Vac 35 lb-in. NSR (floating), w/two aux switches MF Vac 35 lb-in. NSR (floating), feedback potentiometer MF-6203 MF Vac 70 lb-in. spdt NSR (floating) MF-6633 MF Vac 133 lb-in. spdt NSR (floating) MF-6733 MF Vac 300 lb-in. spdt NSR (floating) MF-7103 MF Vac 35 lb-in. (floating) MF MF Vac 35 lb-in. w/aux switch (floating) 26
27 SEC P/N Invensys P/N Description MS-6103 MS Vac 35 lb-in. NSR (proportional) MS Vac 35 lb-in. NSR (proportional), w/two aux switches MS Vac 35 lb-in. NSR (proportional), adjustable start point (offset) and span MS Vac 35 lb-in. NSR (proportional), w/two aux switches, adjustable start point (offset) and span MS-6203 MS Vac 70 lb-in Vdc/4-20 madc NSR (proportional) MS-6633 MS Vac 133 lb-in Vdc/4-20 madc NSR (proportional) MS-6733 MS Vac 300 lb-in Vdc/4-20 madc NSR (proportional) MS-7103 MS Vac 35 lb-in. (proportional) MS MS Vac 35 lb-in. w/aux switch (proportional) MS-7203 MS Vac 60 lb-in. (proportional) MS-7433 MS Vac 133 lb-in. (proportional) Belimo to Invensys Actuators Belimo P/N Invensys P/N Description MA Vac 150 lb-in. (2-position) MA Vac 150 lb-in. (2-position) MA Vac 150 lb-in. (2-position) MF Vac 60 lb-in. (floating) MF Vac 60 lb-in. w/aux switch (floating) MF Vac 150 lb-in. (floating) MS Vac 60 lb-in. w/aux switch (proportional) MS Vac 150 lb-in. (proportional) MS Vac 150 lb-in. (proportional) MS Vac 150 lb-in. (proportional) MS Vac 300 lb-in. NSR (proportional) MS Vac 300 lb-in. NSR (proportional) AF120 MA Vac 133 lb-in. (2-position) AF120-S MA Vac 133 lb-in. w/aux switch (2-position) AF230 MA Vac 133 lb-in. (2-position) AF230-S MA Vac 133 lb-in. w/aux switch (2-position) AF24 MA Vac 133 lb-in. (2-position) AF24-3 MF Vac 133 lb-in. (floating) AF24-S MA Vac 133 lb-in. w/aux switch (2-position) AF24-3-S MF Vac 133 lb-in. w/aux switch (floating) AF24-SR MS Vac 133 lb-in. (proportional) AF24-SR-S MS Vac 133 lb-in. w/aux switch (proportional) GM24 MF Vac 300 lb-in. spdt NSR (floating) GM24-SR MS Vac 300 lb-in. 2 to 10 Vdc/4 to 20 madc NSR (proportional) LF120 MA Vac 35 lb-in.s (2-position) LF120-S MA Vac 35 lb-in.s w/aux switch (2-position) LF230 MA Vac 35 lb-in. (2-position) LF230-S MA Vac 35 lb-in. w/aux switch (2-position) LF24 MA Vac 35 lb-in. (2-position) LF24-3 MF Vac 35 lb-in. (floating) LF24-S MA Vac 35 lb-in. w/aux switch (2-position) LF24-3-S MF Vac 35 lb-in. w/aux switch (floating) LF24-SR MS Vac 35 lb-in. (proportional) LF24-SR-S MS Vac 35 lb-in. w/aux switch (proportional) LM24 MF Vac 35 lb-in. NSR (floating) LM24-10P MF Vac 35 lb-in. NSR (floating), feedback potentiometer LM24-S MF Vac 35 lb-in. NSR (floating), w/two aux switches LM24-SR MS Vac 35 lb-in. NSR (proportional) MS Vac 35 lb-in. NSR (proportional), adjustable start point (offset) and span 27
28 Belimo P/N Invensys P/N Description MS Vac 35 lb-in. NSR (proportional), w/two aux switches, adjustable start point (offset) and span MS Vac 35 lb-in. NSR (proportional), w/two aux switches NF120 MA Vac 60 lb-in. (2-position) NF120-S MA Vac 60 lb-in. w/aux switch (2-position) NF230 MA Vac 60 lb-in. (2-position) NF230-S MA Vac 60 lb-in. w/aux switch (2-position) NF24 MA Vac 60 lb-in. (2-position) NF24-S MA Vac 60 lb-in. w/aux switch (2-position) NF24-SR MS Vac 60 lb-in. (proportional) NM24 MF Vac 70 lb-in. spdt NSR (floating) NM24-SR MS Vac 70 lb-in. 2 to 10 Vdc/4 to 20 madc NSR (proportional) SM24 MF Vac 133 lb-in. spdt NSR (floating) SM24-SR MS Vac 133 lb-in. 2 to 10 Vdc/4 to 20 madc NSR (proportional) Invensys and DuraDrive are trademarks of Invensys plc and its subsidiaries and affiliates. F Specifications may change as design improvements are introduced. Printed in U.S.A.
Electric Smoke Damper Actuators
Bulletin Issue Date May 20, 2004 Electric Smoke Damper Actuators The Modulating Electric Smoke Damper Actuators are oil immersed, spring return, linkage coupled actuator for modulating damper control designed
More information10260 Series Actuators Model Selection Guide
Issue 6 Page 1 of 5 2 Series Actuators Model Selection Guide Instructions Select the desired key number. The arrow to the right marks the selection available. Make one selection each from Table I thru
More informationEPM Series Reversing Electric Actuators
EPM Series Reversing Electric Actuators Innovative Quarter-Turn Actuators that Look the Same on the Outside with the Hayward Difference on the INSIDE! Overview On/Off and Proportional Control Models Designed
More informationModel Number Structure
Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via
More information10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC
Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external
More informationMounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B
A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles
More informationPower Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops
Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated
More informationModel Crosspoint Matrix
Model 3000 4380 256 Crosspoint Matrix 90401270 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part
More informationNIBCO PNEUMATIC ACTUATORS
ACT-0718 ACTUATORS AND CONTROLS FOR METAL & CHEMTROL VALVES Effective July 2, 2018 Supercedes ACT-0117 dated January 2, 2017 Suggested List Prices Subject to Change Without Notice. NIBCO PNEUMATIC ACTUATORS
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands
More informationBall Valve Manual Balance Hose Kits - Submittal
Ball Valve Manual Balance Hose Kits - Submittal Hose Kit Size *MFR 1/2" 5 3/4" 11 1" 20 1-1/4" 30 **1-1/2" 44 **2" 78 Qty. *MFR (Max. Flow Recommendations) calculated at 8 fps. **1-1/2 and 2 hose kits
More informationSafety Interlock Switches
r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables
More informationPCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)
PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and
More informationEmergency Stop Devices
New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com
More informationType Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder
A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with
More informationLimit Switches. 6.2 E47 Precision Switches
Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description............................................. 2 Approvals..................................................... 2 Features and Benefits...........................................
More informationDual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series
Dual Modular Safety Shutoff Valves with Proof of Closure Option DMV eco Series DMV-D eco Series DMV-DLE eco Series Two normally closed safety shutoff valves in one housing; each with the following approvals.
More information630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.
SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and
More informationGeneral-purpose Relay
General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals
More informationMOTORIZED OR MANUAL LATERAL ARM BOX AWNING. Product Overview... 1 Component Checklist... 2
INSTALLATION MANUAL FREEDOM AWNING RV MOTORIZED OR MANUAL LATERAL ARM BOX AWNING TABLE OF CONTENTS Product Overview... 1 Component Checklist... 2 Installation... 3 Attaching the Mounting Plates... 3 Mounting
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High
More informationPlug-in/solder terminals with LED indicator
General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole
More informationSPEDESTER Series QUICK REFERENCE GUIDE
Spedester series Digital DC Drives come with an extensive range of standard software blocks, it can take control of the most demanding motion control tasks. Designed for industrial applications, Spedester
More informationData Sheet for Precision Potentiometer
AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn
More informationGeneral Purpose High Power PCB Relays
T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL
More informationSIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationData Sheet for Precision Potentiometer
The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19
More informationCASM electric cylinders The modular electric cylinder system
CASM electric cylinders The modular electric cylinder system CASM electric cylinders are ideally suited to performing fast and powerful linear movements. Unlike pneumatic or hydraulic cylinders, CASM electric
More informationDefinite Purpose Contactors 1, 2 and 3 pole Type GDP
Definite Purpose Contactors 1, 2 and 3 pole Type l Definite Purpose Contactors l Switching up to 100A resistive, 90A inductive l Line Voltage up to 600VAC on most sizes l Control voltage up to 480VAC l
More informationFREEDOM WM AWNING MOTORIZED OR MANUAL LATERAL ARM BOX AWNING. Product Overview... 1 Component Checklist... 1
INSTALLATION MANUAL FREEDOM WM AWNING RV MOTORIZED OR MANUAL LATERAL ARM BOX AWNING TABLE OF CONTENTS Product Overview... 1 Component Checklist... 1 Installation... 3 Attaching the Mounting Plates... 3
More information6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description
.1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................
More informationElectronic Temperature Controls
ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple
More informationGeneral-Use Auto-Tuning HPX-T Series
General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display
More informationCASM electric cylinders
CASM electric cylinders 2 The modular electric cylinder system CASM electric cylinders are ideally suited to performing fast and powerful linear movements. Unlike pneumatic or hydraulic cylinders, CASM
More informationr e - p a r t s. c o m
Owner s Manual SPK3E - Manual EASY Control General Assembly, Installation, and Operation Instructions for use with Natural Gas Burners; F, FX, CS, CXF, TNA or Propane Gas Burners: FA, FAX, CA, CXFA, TNA/LP
More informationInduction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors
Standard AC Standard AC Constant Speed Constant Speed Torque Brake V Series TM Series Torque Page Features and s of C-20 General Specifi cations C-28 (6 W 90 W) C-30 IP65 Terminal Box C-48 () C-61 2-Pole,
More informationSPK3E - Manual EASY Control
SPK3E - Manual EASY Control General Assembly, Installation, and Operation Instructions for use with Natural Gas Burners; F, FX, CS, CXF, TNA or Propane Gas Burners: FA, FAX, CA, CXFA, TNA/LP LISTED BY
More informationEC BRUSHLESS MOTOR APPLICATIONS
APPLICATIONS Due to their high efficiency are often used into applications that requires low power consumption combined to high performance. Many versions are available to meet various application requirements:
More informationSupplementary protector S 200 MR for ring-tongue applications acc. to UL 1077
Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC
More informationRMC1E - Variable Flame Height EASY Control
Owner s Manual RMC1E - Variable Flame Height EASY Control General Assembly, Installation, and Operation Instructions for use with Natural Gas Burners; F, FX, CS, CXF, TNA or Propane Gas Burners: FA, FAX,
More informationbutterfly 2 to 12 Siemens 2-way Pneumatic SR
2 to 12 Siemens 2-way Pneumatic SR Normally Closed (Fail Closed) Normally Open (Fail Open) 150 psi Close-off 100 psi Close-off - 4-6 150 psi Close-off 100 psi Close-off - 4-6 Cv 50 psi Close-off - 8-12
More informationLOCAL DISCONNECT SWITCHES Manual Motor Controllers
LOCAL DISCONNECT SWITCHES Manual Motor Controllers 1 2 Ensto Manufacturer of electrical components and systems This brochure presents the economical, versatile and reliable Ensto Origin manual motor controllers
More informationNexus Standard Glove Box System
NOW CONFORMS TO UL AND CSA STANDARDS FOR LABORATORY EQUIPMENT Nexus Standard Glove Box System Vacuum Atmospheres Company Vacuum Atmospheres Company 4652 W. Rosecrans Ave. East Coast Office P.O. Box 1043
More informationFREEDOM WM AWNING. Product Overview... 1 Component Checklist... 2
INSTALLATION MANUAL FREEDOM WM AWNING MOTORIZED OR MANUAL LATERAL ARM BOX AWNING RV Read this manual before installing or using this product. Failure to follow the instructions and safety precautions in
More informationXENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL
TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger
More informationPRODUCT MANUAL - M096
PRODUCT MANUAL - M096 MODEL 270 ELECTRIC CAN OPENER 1 I. LABELS L087--CAUTION 2 II. SPECIFICATIONS MODEL NO. 270 POWER 115 VOLT, 1.5 AMP, 50-60HZ REQUIREMENTS 230 VOLT, 0.8 AMP, 50-60 HZ NORMAL SPEED 200-250
More informationSpecial Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change
Special Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change Catalogue 21 E High speed three-phase motors with HSK-C tool holder for manual tool change protection type: IP54 Motor description
More informationUSER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Tavor 8-T Active Ceiling Speaker P/N: 2900-300343 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions
More informationULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES
ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES UPS MIL-SPEC COMPLIANT 1-5 KVA 1-5 U UNIVERSAL 120/240 VAC PFC INPUT SNMP COMMUNICATIONS WHEN EVERY POUND COUNTS! APPLICATIONS Shelters Tactical Systems Shipboard
More informationIntroduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4
H-206.F2 6-Axis Precision Alignment System Contents Introduction 2 Other Applicable Documents 2 Scope of Delivery 3 Attaching the Snap-on Ferrite Suppressor 4 Connecting the Hexapod to the C-887 with the
More informationDIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions
Analogue Timer Model H3DS-M/-S/-A H3DS-F H3DS-G Features DIN Track Mounting, Standard mm Width, Solid-state Multifunctional Timer with Smart Dial/Selector-locking Mechanism DIN Track Mounting, Standard
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION ISO 900 Certification was achieved in December 997, and reflects the strict adherence to quality management techniques from the first day of production. This certification was given
More information6275-S1 PNEUMATIC DRILL OPERATING MANUAL ORIGINAL INSTRUCTIONS. P/N November 2014 Revision 1
6275-S1 PNEUMATIC DRILL OPERATING MANUAL ORIGINAL INSTRUCTIONS P/N 80749 November 2014 Revision 1 2014 Climax Portable Machining and Welding Systems or its subsidiaries. All rights reserved. Except as
More informationGT371 HEDGETRIMMER TYPE
GT371 HEDGETRIMMER TYPE 1 Introduction Exploded Drawing Bill Of Material Repair Instructions E13791 GT371-----A New Parts Wiring Diagram Main Menu 3 18 02-04 SEAN HOLDEN GT371 MANUFACTURING PLANT USTI
More informationProduct Guide LED OBSTRUCTION LIGHTS
Product Guide LED OBSTRUCTION LIGHTS Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO Aerodromes Design Manual, Chapter 18 Canadian
More informationHEATER POWER CONTROLLER
HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL
More informationL-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights
L-864 L-865 / L-864 L-810 L-810 Vigilant Series LED Based Obstruction Lights Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO
More informationGT370 HEDGETRIMMER TYPE
GT370 HEDGETRIMMER TYPE 1 Introduction Exploded Drawing Bill Of Material Repair Instructions E13791 GT370-----A New Parts Wiring Diagram Main Menu 44 18 02-04 SEAN HOLDEN GT370 MANUFACTURING PLANT USTI
More informationPN 3000 Series Fail Closed Pneumatic Actuators
PN 3000 Series Fail Closed Pneumatic Description A of compact linear actuators having 5 diaphragm sizes for matching the requirements of 1/2" to 4" Spira-Trol valves at various differential pressures.
More informationUser manual for shredder KIT
2014 User manual for shredder KIT Thymark FilaMaker 1.1.2014 User manual shredder KIT 1) what is in your kit. 2) which tool do you need 3) building your shredder step by step 4) Warnings and safety 5)
More informationDuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications
for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Wallpack_Bulkhead_Specsheet_Industrial_Jan2018
More informationSR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features
Series AC Erie Boiler Boss Universal Control Relay General Instructions Application he AC Boiler Boss series zone control relay incorporates a double pole/double throw relay to control a circulator and
More informationTherme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions
Therme storage water heater Table of contents Symbols used... 8 Installation instructions Water supply... 9 Choice of location... 9 Installation of the Therme... 9 Fitting the draining and venting valve...
More informationDouble C-Face Spring-Set Brakes
Double C-Face Spring-Set Brakes POWER TRANSMISSION GUARANTEED ENGINEERING PERFORMANCE KEBCO Combistop type 17 The KEBCO Commitment To provide the highest quality motion control products for power transmission
More informationTrapped Key Transfer System SHGV SVM SVE
Trapped Key Transfer System SHGV SVM SVE Description Area of application Cost Savings The SHGV key transfer system occurs mainly in more complex manufacturing systems and equipment. It is especially suitable
More informationSafeSite. Series LED Based Signaling for Hazardous Locations
SafeSite Series LED Based Signaling for Hazardous Locations Index 02 SafeSite L-864 Red LED Beacon 03 SafeSite LED Based L-864/L-865 Flashing Dual (White/Red) Strobe 04 SafeSite L-810 Red LED Obstruction
More informationMORIN B AND C SERIES ACTUATORS
MORIN B AND C SERIES ACTUATORS B series - Ductile iron w/ stainless steel cylinders, C series - Ductile iron w/ carbon steel cylinders Spring return and double acting actuators Quarter-turn output torques
More informationPGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI
PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore
More informationVFR Parallel Flow, Fan-Powered, VAV Terminals
VFR Parallel Flow, Fan-Powered, VAV Terminals Model VFR construction features Galvanized-steel casing withstands 125-hour, salt-spray test per ASTM B-117 All unit configurations listed with ETL for safety
More informationSection 11 Workstation Components
1 Section Quick and easy access to parts is made possible by the wide variety of trays, bins, and framing components available from Bosch. Individual workstation grab trays, containers, and ledges place
More informationE2 Motors and Motor Starting. #1 Fan Motors
E2 Motors and Motor Starting #1 Fan Motors Basic Electric Motor Stator Stationary electromagnet Rotor Rotating magnet Movement of the rotor Rotates by repulsion and attraction of stator 2005 Refrigeration
More informationProduct Overview... 3 Component Checklist Installation... 4 Installation Using an Awning Rail... 4
INSTALLATION MANUAL MARQUEE WINDOW AND OTD AWNINGS RV Read this manual before installing or using this product. Failure to follow the instructions and safety precautions in this manual can result in personal
More informationOREON GROW LIGHT 2.2
OREON GROW LIGHT 2.2 (GL 600 2.2 XXX) INSTALLATION MANUAL Version: 20180830US/CA IMPORTANT: READ CAREFULLY BEFORE STARTING INSTALLING THE FIXTURE. KEEP FOR FUTURE REFERENCE. MANUAL FOR INSTALLER Thank
More informationQK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz
user manual QK-CE220RL V02 CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR 230V 433,92 MHz PLUG & PLAY CONTENTS INTRODUCTION MAIN FEATURES OF THE CONTROL BOARD TECHNICAL DATA INSTALLATION LAYOUT AND CONNECTIONS
More informationProduct Overview... 1 Component Checklist...2
INSTALLATION MANUAL FREEDOM AWNING RV MOTORIZED PATIO BOX AWNING TABLE OF CONTENTS Product Overview... 1 Component Checklist...2 Installation... 3 Installation Using an Awning Rail...3 Installation Using
More informationB-Series Switches Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage treatment
More informationMODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW
MODEL CM OVERVIEW The CM Series belt driven backward inclined Utility Vent Set fans from S&P offer an excellent choice of product for all medium and high pressure exhaust or supply applications for commercial,
More informationDialight LED High Bay - High Output. Technical Specification Sheet - Americas
Dialight LED High Bay - High Output Technical Specification Sheet - Americas NOVEMBER 2018 High Bay - High Output High Bay Standard Corded Models Vigilant LED High Bay - High Output Standard Models Certifications
More informationTuf-Lite and Tuf-Lite II Fans 6000M Series Hub
Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 32.8 or 10 Meter Diameter Hudson Tuf-Lite and Tuf-Lite II fan blades Hudson Tuf-Lite (black) fan blades
More informationUniversal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W
isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP
More informationAWNING CONTROL KIT 98GCK-33B
AWNING CONTROL KIT 98GCK-33B REV.07282015 RV AWNING PRODUCTS 1361 CALLE AVANZADO, SAN CLEMENTE, CA 92673 (800) 382-8442 FAX (949)276-5500 www.girardrv.com AC MOTOR CONTROL MODULE GC274B INSTALLATION and
More informationAmbient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage
SSR Power Controller SSR 1 SSR 2 SSR 3 Phase Single 2 Leg Switching 3 Phase DIN Rail/Panel Mounting Both Both Both Cooling Fan Optional Optional Optional Control MethodZero Cross Trigger / high isolation
More informationDeZURIK AM-SERIES MANUAL GEAR ACTUATOR USED ON BUTTERFLY VALVES
AM-SERIES MANUAL GEAR ACTUATOR USED ON BUTTERFLY VALVES Instruction D10501 January 2015 Instructions These instructions provide information about AM-Series Manual Actuators used on Butterfly Valves. They
More informationELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor
PRODUCT SPECIFICATIONS AIR HANDLERS CBA7UHE ELITE Series R-0A - Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 067 October 07 Supersedes April 07 MODEL NUMBER IDENTIFICATION CB A 7 UH
More informationFILTERED FAN PACKAGES
FILTERED FAN PACKAGES PLASTIC & METAL FILTERED FANS EFFICIENT, QUITE BALL BEARING MOTORS NEMA TYPE 1 AND 3R ALL KITS INCLUDE GASKETS, HARDWARE, AND TEMPLATE UL LISTED Plastic FILTER FAN PACKAGES Injection
More informationSERVICE SHEET 34" WALK-BEHIND POWER TROWEL MODEL FT34 (THIS SERVICE SHEET APPLIES TO THE TROWELS WITH SERIAL NUMBER AND AFTER) WARNING
34" WALK-BEHIND POWER TROWEL (THIS APPLIES TO THE TROWELS WITH SERIAL NUMBER 0837 AND AFTER) WARNING To reduce the risk of injury, all operators and maintenance personnel must read and understand these
More informationEclipse Hermetic Gas Boosters Series HB
Datasheet 620 7/6/2012 Eclipse Hermetic Gas Boosters Series HB Version 1.1 Type Designations The booster is identified by catalog model, assembly number, and ordering part number. The catalog model number
More informationFREEDOM RM AWNING. Product Overview... 1 Component Checklist... 2 Freedom RM Bracket Kits... 3
INSTALLATION MANUAL FREEDOM RM AWNING RV ROOF MOUNTED BOX AWNING TABLE OF CONTENTS Product Overview... 1 Component Checklist... 2 Freedom RM Bracket Kits... 3 Installation... 4 Bracket Installation...
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationPrimrose Awnings - Full Cassette Manual & Electric Instructions
Primrose Awnings - Full Cassette Manual & Electric Instructions Contents Warning 2.0m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m - 5.0m Awnings 12 x Expansion bolts **
More informationEngineering Design Assurance Test Report ( S )
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationSection B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1
Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe
More informationew Cove QLX Powercore
Date: Type: Firm Name: Project: 153.8 (6.6 Performance interior linear LED cove and accent fixture with solid white light Ordering Information (1.8 60 x 90 193 (7.6 25 (.5 (1 205.7 (8.1 (1 (.5 1218.5 (48(1.25
More informationSection B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1
Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe
More informationGas Conversion Kits and Instructions
Gas Conversion Kits and Instructions INSTALLATION FORM RGM 432/433-GC (Version D.1) Obsoletes Form RGM 432/433-GC (Version D) APPLIES TO: Model FT and Model SFT All gas conversion must be done by a qualified
More informationecostar ecostar Outdoor Spec Sheets 2013
Spec Sheets 2013 LED Street Light 50,000 Hours average rated life, 100-277 Volts 70 230 Watt Low Power and High Performance Long Lifetime and High uniformity Energy saving and maintenance free Unique design
More informationFREEDOM RM AWNING. Product Overview... 1 Component Checklist... 2 Freedom RM Bracket Kits... 3
INSTALLATION MANUAL FREEDOM RM AWNING RV ROOF MOUNTED BOX AWNING TABLE OF CONTENTS Product Overview... 1 Component Checklist... 2 Freedom RM Bracket Kits... 3 Installation... 4 Bracket Installation...
More informationJameco SKU Number:
Jameco SKU Number: 2105560 SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER LINE REGULATION LOAD REGULATION HOLD U
More informationModel Number Structure
The reliable choice for Hockey-puck-style Solid State Relays. Available in a wide Range of Currents and Voltage. (5 to 90A, max 660 VAC) All models feature the same compact dimensions to provide a uniform
More informationTENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:
TENDABOX Description One-piece U-shaped protective cover (Dimension 179 x 145 mm), as from 500 cm total width protective cover inner reinforcement (Dimension 179 x 145 mm), of extruded aluminium profile
More information