Electronic Temperature Controls

Size: px
Start display at page:

Download "Electronic Temperature Controls"

Transcription

1 ETR-9090 series ETR-9200 series Figure 324 Figure vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR any thermocouple 3a, vac SPDT relay ETR ETR vdc, 20ma max. ETR ETR ma isolated linear ETR ETR RTD Pt ohms 3a, vac SPDT relay ETR ETR vdc, 20am max ETR vac /60Hz PID auto tune/ or 1 set point 3" depth 2 optional alarms NEMA 4X 4-20 ma PV re-transmission Model Sensor type Output action Alarm ETR any thermocouple 3a, vac SPDT relay ETR ETR vdc, 20ma max. ETR ETR ma isolated linear ETR ETR RTD Pt ohms 3a, vac SPDT relay ETR ETR vdc, 20ma max ETR Figure 326 ETR-9300 series remote set point capable digital communications 2 set points loop break alarm bumpless transfer 1 optional alarm heater break alarm low voltage Input Model Power input Input Output action Output action 2 Alarm Communications ETR vac /60Hz Thermocouple 3a, vac SPST relay none none none ETR RTD 2A/vac Form A relay 4-20ma/0-20ma ETR ma/0-20ma SSR, 5V/30a, 4-20ma/0-20ma ETR v, 0-5v, 1-5v, 0-10v 4-20ma/0-20ma ETR ma/0-20ma ETR vac or vdc ETR9300-xxxxx Many other options available Available K 3

2 ETR-9000 series Figure 327 universal input (red or green) vac /60Hz 2 outputs VAC or VDC Model Sensor type Output 1 Output 2 ETR9000 Universal input Relay, 2A/ vac none 41 Thermocouple, ETR9000 RTD, Relay, 2A/ vac 4-20ma/)-20ma ma, voltage ETR9000 SSR-5V/30ma none 40 ETR9000 SSR-5V/30ma SSR-5V/30ma ETR ma/0-20ma none ETR ma/0-20ma 4-20ma/0-20ma Proportional or vac 3 3 / 8 " depth ETR-901 series Figure 328 ETR J thermocouple relay -8 F 3a, vac SPST relay ETR SSR, 32 vdc, 20ma max. ETR a, vac SPST relay PID or 3 3 / 8 " depth, deviation lights Model Sensor type Output action Temperature Range Power Input ETR J thermocouple -8 F vac 3a, vac SPST relay ETR SSR, 32vdc, 20ma max. ETR-902 series Figure 329 ETR F vac 3a, vac SPST relay ETR F 3a, vac SPST relay ETR vac 3a, vac SPST relay ETR SSR, 32vdc, 20ma max. ETR SSR, 32vdc, 20ma max. vac K4

3 1/8th DIN 2 1 / 2 " depth PID-auto tune, or front panel set-up vdc/vac available ETR any thermocouple 3a, vac SPDT relay no alarm ETR ETR SSR 32 vdc, 20ma max. no alarm ETR ETR ma, isolated, linear no alarm ETR ETR RTD-PT ohms 3a, vac SPDT relay ETR DIN curve 4-20ma, isolated,linear 2a,vac SPST relay Figure 330 1/8th DIN 2 outputs - heat/cool 2 1/ 2 " depth PID-auto tune, or front panel set-up ETR-8 series ETR-8130 series ETR any thermocouple 3a, vac SPDT relay ETR ETR RTD-PT ohms ETR DIN curve front panel set-up 2" depth PID-auto tune, or ETR any thermocouple 3a, vac SPDT relay ETR ETR ma, isolated, linear ETR RTD-PT ohms ETR-4130 series ETR-4 series Figure 331 front panel set-up 2 outputs heat/cool 2" depth PID-auto tune, or ETR any thermocouple 3a, vac SPDT relay ETR ETR RTD-PT ohms ETR DIN curve K5

4 ETR-401 series Figure vac 2 " depth ETR J thermocouple - 8 F 3a, vac SPDT relay ETR a, vac SPDT relay ETR K thermocouple Proportioning 1-0 C 3a, vac SPDT relay vac 2 " depth indicating ETR-404 series Figure 333 ETR J thermocouple Proportioning - 8 F 3a, vac SPDT relay ETR K thermocouple Proportioning 1-0 C 3a, vac SPDT relay high limit control surface mount or DIN rail FM approved manual reset optional DC output for SSR ETR-3 high limit series Figure 334 ETR3-01 J thermocouple volt / 3.8amp v max F ETR3-02 K thermocouple volt / 3.8amp v max F ETR3-03 J thermocouple volt / 3.8amp v max F ETR3-05 J thermocouple volt / 3.8amp v max 0-7 F ETR3-06 J thermocouple 24vac / 3.8amp v max F ETR3-09 RTD volt / 3.8amp v max 0-8 F ETR3-17 J thermocouple volt / 3.8amp v max F high limit latching relay auto reset surface mount, no enclosure -260 vax manual reset requires remote push button Figure 335 ETR-4 high limit series ETR4-02 J thermocouple 20a, vac SPDT relay 0-0 F & 0-0 C ETR4-03 K thermocouple 20a, vac SPDT relay F & 0-1 C K6

5 Control Panels & Miscellaneous Accessories NEMA 4 enclosure selector switch volt control circuit door interlock disconnect switch fused control circuit transformer fused magnetic contactor(s) multiple circuit systems have time delay between circuit on duty dual insulating electronic temperature control high limit control with manual reset pilot lights for - system on, heat on & high limit custom panels also available Disconnect amp Maximum load amps No. of circuits/amps per circuit Enclosure size Catalogue no x 24 1 x 48 2 x x 20 x 8 CP-030 CP-060 CP- Figure 336 Control Panels (specifiy voltage and phase when ordering) B 31/2 11/2 Figure 337 Catalogue no, volts watts Catalogue no, volts watts ASB B ASB B ASB B ASB B ASB B ASB B ASB B ASB B ASB B ASB B ASB B ASB B ASB B ASB B ASB B Enclosure Heater (Also available without box) watts Figure 338 volts or Catalogue no. SCB-0 SCB-075 SCB- SCB-1 SCB-200 (specifiy voltage when ordering) Screw Base Heater Surface Mount Control Contacts open on temperature rise Model number B0 0.80" " " 2 75 to 600 F vac, maximum 10 watts, maximum Figure 339 Control Panel Thermostat 21/8 13/4 Model number DPC /8 15/16 Figure 340 K7 10 amp vac 5 amp vac Temperature setting opens at 45 F ± 5 closes at 35 F ± 6 12 lead wires, rated at 105 F

SPEDESTER Series QUICK REFERENCE GUIDE

SPEDESTER Series QUICK REFERENCE GUIDE Spedester series Digital DC Drives come with an extensive range of standard software blocks, it can take control of the most demanding motion control tasks. Designed for industrial applications, Spedester

More information

Model Number Structure

Model Number Structure Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via

More information

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore

More information

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions Analogue Timer Model H3DS-M/-S/-A H3DS-F H3DS-G Features DIN Track Mounting, Standard mm Width, Solid-state Multifunctional Timer with Smart Dial/Selector-locking Mechanism DIN Track Mounting, Standard

More information

General Purpose High Power PCB Relays

General Purpose High Power PCB Relays T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL

More information

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage SSR Power Controller SSR 1 SSR 2 SSR 3 Phase Single 2 Leg Switching 3 Phase DIN Rail/Panel Mounting Both Both Both Cooling Fan Optional Optional Optional Control MethodZero Cross Trigger / high isolation

More information

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately) PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and

More information

HEATER POWER CONTROLLER

HEATER POWER CONTROLLER HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL

More information

EPM Series Reversing Electric Actuators

EPM Series Reversing Electric Actuators EPM Series Reversing Electric Actuators Innovative Quarter-Turn Actuators that Look the Same on the Outside with the Hayward Difference on the INSIDE! Overview On/Off and Proportional Control Models Designed

More information

General-Use Auto-Tuning HPX-T Series

General-Use Auto-Tuning HPX-T Series General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display

More information

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles

More information

10260 Series Actuators Model Selection Guide

10260 Series Actuators Model Selection Guide Issue 6 Page 1 of 5 2 Series Actuators Model Selection Guide Instructions Select the desired key number. The arrow to the right marks the selection available. Make one selection each from Table I thru

More information

Safety Interlock Switches

Safety Interlock Switches r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables

More information

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.

More information

Heating and Cooling Components. Application Selection and Cross-Reference Guide

Heating and Cooling Components. Application Selection and Cross-Reference Guide Heating and Cooling Components Application Selection and Cross-Reference Guide CONTACTORS Heat Sequencers REAYS TRANSFORMERS The Universal Choice Honeywell offers a complete range of relays, contactors

More information

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description .1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................

More information

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2  Certifications W isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP

More information

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High

More information

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories) MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system

More information

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands

More information

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination. SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and

More information

General-purpose Relay

General-purpose Relay General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals

More information

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES 1 MANUFACTURER: MODEL: NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI 54115 UNITED STATES NORTHFIELD CLS SPECIFICATIONS: VOLTAGE: FREQUENCY: CURRENT: AIR: 115VAC-230VAC 50/60Hz 5 AMP 80 PSI (for

More information

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W CV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications

More information

Feature. Model comment JG 3NA B L - B - D3

Feature. Model comment JG 3NA B L - B - D3 Feature Device type universal nut terminals with safety protective cover -A Power Output Rated load voltage 20VAC/VAC Triac power switch Have DC-AC (DC signal to control the AC load) AC-AC (AC signal to

More information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with

More information

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web:  - SVL Essential DIN Rail Series SVL Series power supplies are perfect for high volume, controlled environment applications where essential features are the only requirement. When space inside an enclosure

More information

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series Dual Modular Safety Shutoff Valves with Proof of Closure Option DMV eco Series DMV-D eco Series DMV-DLE eco Series Two normally closed safety shutoff valves in one housing; each with the following approvals.

More information

Emergency Stop Devices

Emergency Stop Devices New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com

More information

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation. DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_156_a_2_cat Direct

More information

ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor

ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor PRODUCT SPECIFICATIONS AIR HANDLERS CBA7UHE ELITE Series R-0A - Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 067 October 07 Supersedes April 07 MODEL NUMBER IDENTIFICATION CB A 7 UH

More information

Operational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue

Operational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue Complete Assemblies Knob-type Selector Switch Install in 22-mm dia. or 25-mm dia. Panel Cutout H Illuminated and Non-illuminated models H Locking lever ensures easy mounting and removal of switch unit

More information

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features Series AC Erie Boiler Boss Universal Control Relay General Instructions Application he AC Boiler Boss series zone control relay incorporates a double pole/double throw relay to control a circulator and

More information

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

Definite Purpose Contactors 1, 2 and 3 pole Type GDP Definite Purpose Contactors 1, 2 and 3 pole Type l Definite Purpose Contactors l Switching up to 100A resistive, 90A inductive l Line Voltage up to 600VAC on most sizes l Control voltage up to 480VAC l

More information

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no. NH fuse-switch-disconnector NH fuse-switchdisconnector ~ 690V screw fixing of disconnectors onto plates size rated current in A no. of poles terminal version art. group 00 160 1 screw M8 both sides F229292

More information

VFR Parallel Flow, Fan-Powered, VAV Terminals

VFR Parallel Flow, Fan-Powered, VAV Terminals VFR Parallel Flow, Fan-Powered, VAV Terminals Model VFR construction features Galvanized-steel casing withstands 125-hour, salt-spray test per ASTM B-117 All unit configurations listed with ETL for safety

More information

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz user manual QK-CE220RL V02 CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR 230V 433,92 MHz PLUG & PLAY CONTENTS INTRODUCTION MAIN FEATURES OF THE CONTROL BOARD TECHNICAL DATA INSTALLATION LAYOUT AND CONNECTIONS

More information

Plug-in/solder terminals with LED indicator

Plug-in/solder terminals with LED indicator General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole

More information

AWNING CONTROL KIT 98GCK-33B

AWNING CONTROL KIT 98GCK-33B AWNING CONTROL KIT 98GCK-33B REV.07282015 RV AWNING PRODUCTS 1361 CALLE AVANZADO, SAN CLEMENTE, CA 92673 (800) 382-8442 FAX (949)276-5500 www.girardrv.com AC MOTOR CONTROL MODULE GC274B INSTALLATION and

More information

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL Total solder points: 129 Difficulty level: beginner 1 2 3 4 5 advanced LIQUID LEVEL CONTROLLER K2639 Forgotten to turn off the tap, leaking washing machines,... Prevention is better than cure. So use this

More information

Product information Truma VarioHeat and E-Kit. July 2018

Product information Truma VarioHeat and E-Kit. July 2018 Product information Truma VarioHeat and E-Kit July 018 Truma VarioHeat The new compact Truma heaters for motor homes, caravans and vans. Truma VarioHeat eco and Truma VarioHeat comfort are of an identical

More information

COCKPIT USB POWER INTEGRATION

COCKPIT USB POWER INTEGRATION COCKPIT USB POWER INTEGRATION POWER SHORTAGE IN COCKPIT With today s technology, the struggle for airlines to keep up with EFB and other battery powered electronics to stay charged during flight creates

More information

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants BCS PRODUCT SPECIFICATIONS Suitable for use with R- and R-0A refrigerants.5 to 5 Tons Upflow and Horizontal (Counterflow with optional kit) Pre-painted cabinets with foil faced insulation Electrical connections

More information

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction Pushbutton Switch Install in 22-dia. or 25-dia. Panel Cutout Easy mounting and removal of Switch Unit. Increase wiring efficiency with three-row mounting of Switch Unit. Finger protection mechanism on

More information

CADDY CORPORATION. Hot Food Caddys

CADDY CORPORATION. Hot Food Caddys Food Service Equipment Air Systems page of 7 Open or Heated / Regular or Slimline REGULAR STRAIGHT FULL CONVENIENCE SLIMLINE STRAIGHT SLIMLINE L-SHAPED (TF-604 & TF-624 Shown) (TF-66 & TF-66 Shown) (TF-64

More information

Project: Four Seasons Hotel, London

Project: Four Seasons Hotel, London Project: Four easons otel, ondon Guest Room Type GR Details label to be located on every Ashdown s ler enclosure cover: Guest Room / Guest uite reference to be included. abel to detail that electrical

More information

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns: 7-1 Section 7 Using the Illustrated List The parts lists provided in this section are organized into the following columns: Item Identifies illustrated parts that are available from Nordson Corporation.

More information

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

LOCAL DISCONNECT SWITCHES Manual Motor Controllers LOCAL DISCONNECT SWITCHES Manual Motor Controllers 1 2 Ensto Manufacturer of electrical components and systems This brochure presents the economical, versatile and reliable Ensto Origin manual motor controllers

More information

When most people build their avionics package,

When most people build their avionics package, nuts & bolts technical counselor The Avionics Master To protect and defend GEORGE R. WILHELMSEN When most people build their avionics package, they mostly think about the great avionics they want to put

More information

Model Crosspoint Matrix

Model Crosspoint Matrix Model 3000 4380 256 Crosspoint Matrix 90401270 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CXM ELITE SERIES R-0A Ready - Multi-Position ulletin No. 0 March 0 Supersedes February 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMER IDENTIFICATION

More information

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated 02.17312.21

More information

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns: 7-1 Section 7 Using the Illustrated List The parts lists provided in this section are organized into the following columns: Item Identifies illustrated parts that are available from Nordson Corporation.

More information

NIBCO PNEUMATIC ACTUATORS

NIBCO PNEUMATIC ACTUATORS ACT-0718 ACTUATORS AND CONTROLS FOR METAL & CHEMTROL VALVES Effective July 2, 2018 Supercedes ACT-0117 dated January 2, 2017 Suggested List Prices Subject to Change Without Notice. NIBCO PNEUMATIC ACTUATORS

More information

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424

More information

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP078-150 JOB NAME: PURCHASER: LOCATION: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED

More information

MBM StitchFold Trimmer

MBM StitchFold Trimmer MBM StitchFold Trimmer Operator Manual Provided By http://www.mybinding.com http://www.mybindingblog.com OPERATION MANUAL Trimmer Trimmer Trimmer CONTENTS Introduction... 3 Specifications... 3 Safety...

More information

Limit Switches. 6.2 E47 Precision Switches

Limit Switches. 6.2 E47 Precision Switches Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description............................................. 2 Approvals..................................................... 2 Features and Benefits...........................................

More information

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1 Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe

More information

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn

More information

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424

More information

Portable Power Distribution for Generator Applications

Portable Power Distribution for Generator Applications Portable Power Distribution for Generator Applications PowerHOUSE Portable Distribution Boxes PowerFLEX Cable Assemblies PowerGATE Switches & Panels PowerPARTS Wiring Devices 060308 About Lex Products

More information

212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad

212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad Stand Alone Keypad-Installation Manual Features: 120 User Capability

More information

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can.

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can. BR-220/BR-200 Burnisher Model No.: 608342 BR-220 609248 BR-220 Can. Pac 608340 BR-200 609247 BR-200 Can. Pac Operator and Parts Manual NOBLES 1287 RANSOM STREET HOLLAND MI 49424 U.S.A. CUSTOMER SERVICE:

More information

Nexus Standard Glove Box System

Nexus Standard Glove Box System NOW CONFORMS TO UL AND CSA STANDARDS FOR LABORATORY EQUIPMENT Nexus Standard Glove Box System Vacuum Atmospheres Company Vacuum Atmospheres Company 4652 W. Rosecrans Ave. East Coast Office P.O. Box 1043

More information

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424

More information

Pelican AMR Gateway User Guide

Pelican AMR Gateway User Guide Pelican AMR Gateway User Guide Document Reference: 8194 June 2016 Version: 2 Version Date Author Changes Number 1 Feb 2014 Bettina Rubek-Slater 2 Jun 2016 Sam Smith Branding updated API section updated

More information

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR037-150, ZF078-150 JOB NAME: PURCHASER: LOCATION: ORDER NO: ENGINEER: SUBMITTED TO:

More information

Congratulations on your decision to enjoy the finest spa available. Welcome to the growing family of Hot Spot Spa owners.

Congratulations on your decision to enjoy the finest spa available. Welcome to the growing family of Hot Spot Spa owners. Congratulations on your decision to enjoy the finest spa available. Welcome to the growing family of Hot Spot Spa owners. Pre-Delivery Instructions Please take the time to read this booklet carefully,

More information

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST: TEST EQUIPMENT LIST: INPUT FUNCTION TEST AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy

More information

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST: TEST EQUIPMENT LIST: INPUT FUNCTION TEST AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy

More information

DUAL COLOR, LOW-PROFILE

DUAL COLOR, LOW-PROFILE GET NOTICED WITH THE DUAL COLOR, LOW-PROFILE ALLEGIANT GET NOTICED WITH THE INCREDIBLY AFFORDABLE ALLEGIANT LIGHT BAR. Introducing Allegiant from Federal Signal, a dual color LED, low-profile linear light

More information

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19

More information

Feasibility of Battery Backup for Flight Recorders

Feasibility of Battery Backup for Flight Recorders KEYWORDS Aviation Cockpit Voice Recorder Flight Data Recorder Battery backup Feasibility of Battery Backup for Flight Recorders Duncan W. Schofield AlliedSignal Inc., Air Transport & Regional Avionics

More information

SUBMITTAL DATA SHEET COOLING PERFORMANCE HEATING PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE ELECTRICAL DATA TOTAL UNIT WEIGHT

SUBMITTAL DATA SHEET COOLING PERFORMANCE HEATING PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE ELECTRICAL DATA TOTAL UNIT WEIGHT SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: DM/DF/DH078-120, DJ150, DR090-150, ZH/ZJ037-150, ZF/ZR078-150 JOB NAME: PURCHASER: LOCATION:

More information

WARNING. Effective Date: 1-03

WARNING. Effective Date: 1-03 Effective Date: 1-03 TECHNICAL MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE GAYLORD "ClearAir"TM MODEL "TPF" SERIES POLLUTION CONTROL UNITS WITH FM-100 SERIES MONITOR STATION WARNING Improper

More information

UNODOS + / FLOCDOS +

UNODOS + / FLOCDOS + Operation manual UNODOS+ / FLOCDOS+ (01-09) page 1 of 7 UNODOS + / FLOCDOS + Table of contents page 1. Technical description... 2 1.1 The function... 2 1.2 Technical details... 2 1.3 The dosing performance...

More information

Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36

Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36 Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36 1.Summary This counter can interface with Screw Feeder FM-36 by setting the number of batches/screws, to be fed, directly into this

More information

12V MOTION SENSOR 98GC779G INSTALLATION & PROGRAMMING GUIDE REV RV AWNING PRODUCTS

12V MOTION SENSOR 98GC779G INSTALLATION & PROGRAMMING GUIDE REV RV AWNING PRODUCTS 12V MOTION SENSOR 98GC779G INSTALLATION & PROGRAMMING GUIDE REV.07242015 RV AWNING PRODUCTS 1361 CALLE AVANZADO, SAN CLEMENTE, CA 92673 (800) 382-8442 FAX (949)276-5500 www.girardrv.com Girard Systems

More information

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spot Spa owners.

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spot Spa owners. Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spot Spa owners. Pre-Delivery Instructions Please take the time to read this booklet carefully,

More information

CREW REST MODULE CMM DESCRIPTION AND OPERATION

CREW REST MODULE CMM DESCRIPTION AND OPERATION -00001 DESCRIPTION AND OPERATION 1. General A. The Crew Rest Module is designed to provide accommodation for two flight crew members who will be carried on the subject aircraft as a spare flight crew for

More information

Test Report: HEP

Test Report: HEP Test Report: HEP-600-24 600W Single Output Switching Power Supply DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Control Function Test Component Stress Test SAFETY

More information

INSTRUCTION BULLETIN

INSTRUCTION BULLETIN INSTRUCTION BULLETIN No. 340169 Machine: 6100E, Nobles Rascal Published: 7-03 Rev. 02 NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the Parts List in the appropriate place in

More information

Garmin GNC 420 GPS Navigator with VHF COM

Garmin GNC 420 GPS Navigator with VHF COM Cirrus Design Section 9 Pilot s Operating Handbook and FAA Approved Airplane Flight Manual Supplement for Garmin GNC 420 GPS Navigator with VHF COM When a GARMIN GNC 420 GPS Navigator with VHF COM is installed

More information

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1 Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe

More information

Model. Oasis Automatic and Manual RV Door Awning System INSTALLATION & OPERATING INSTRUCTIONS

Model. Oasis Automatic and Manual RV Door Awning System INSTALLATION & OPERATING INSTRUCTIONS Oasis Automatic and Manual RV Door Awning System USA SERVICE OFFICE Dometic Corp. 509 So. Poplar St. LaGrange, IN 46761 260-463-4858 CANADA Dometic Dist. 866 Langs Dr. Cambridge, Ontario CANADA N3H 2N7

More information

AFC-50 Automatic French Fry Cutter Instruction Manual

AFC-50 Automatic French Fry Cutter Instruction Manual AFC-50 Automatic French Fry Cutter Instruction Manual Fry Factory Inc. 67 Watts Ave, Charlottetown, PEI, C1E 2B7, Canada Phone: 902-368-2900 Fax: 902-368-8645 Email: info@fryfactoryinc.com Website: www.fryfactoryinc.com

More information

Product Overview... 3 Component Checklist Installation... 4 Installation Using an Awning Rail... 4

Product Overview... 3 Component Checklist Installation... 4 Installation Using an Awning Rail... 4 INSTALLATION MANUAL MARQUEE WINDOW AND OTD AWNINGS RV Read this manual before installing or using this product. Failure to follow the instructions and safety precautions in this manual can result in personal

More information

WELCOME TO ELCOM OUR UPCOMING FACILITY IN FIVE STAR KAGAL MIDC, KOLHAPUR

WELCOME TO ELCOM OUR UPCOMING FACILITY IN FIVE STAR KAGAL MIDC, KOLHAPUR ELCOM WELCOME TO ELCOM Elcom International Pvt. Ltd. is an Electro-Mechanical and Electronic (EM&E) manufacturing company known best for being the pioneers in this industry in India. Established in 1981,

More information

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W OCV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications

More information

Since the voltage was bad at the power pedestal, the problem was not with the motorhome.

Since the voltage was bad at the power pedestal, the problem was not with the motorhome. 1 of 5 2/7/2015 5:48 AM The following was copied with the authors (Daryl Daughters) permission from the Newmarowners Yahoo Group Read why it is so important to check the Campground service before you plug

More information

DATE PURCHASED: DATE INSTALLED: DEALER: ADDRESS: TELEPHONE:

DATE PURCHASED: DATE INSTALLED: DEALER: ADDRESS: TELEPHONE: Vacanza Series Pre-Delivery Instructions Please take the time to read this booklet carefully, as it will provide you with the information you will need to ensure the safe, secure, and timely installation

More information

B-Series Switches Temperature Switches

B-Series Switches Temperature Switches FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage treatment

More information

With our PES/PSS+USB system. everybody gets a great experience!

With our PES/PSS+USB system. everybody gets a great experience! With our PES/PSS+USB system everybody gets a great experience! { The PES/PSS+USB System Inflight Canada s Passenger Entertainment and Passenger Services System has the patent protected and unique feature

More information

Coleman Mach Rv Air Conditioner Repair Parts

Coleman Mach Rv Air Conditioner Repair Parts We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with coleman mach rv air

More information

PLATINUM MODEL WITH AUTO-RETRACT AND REMOTE CONTROL. Owner s Manual

PLATINUM MODEL WITH AUTO-RETRACT AND REMOTE CONTROL. Owner s Manual PLATINUM MODEL WITH AUTO-RETRACT AND REMOTE CONTROL Owner s Manual THIS MANUAL CONTAINS INSTRUCTIONS FOR UPGRADING BOTH THE GOLD MODEL ONE-TOUCH AND THE ONE-TOUCH MODEL WITH THE KEY SWITCH TO THE PLATINUM

More information

Hiway Gateway Specification and Technical Data

Hiway Gateway Specification and Technical Data L Hiway Gateway Specification and Technical Data HG03-400 8/92 detergant coffee chocolate Page 2 TDC 3000 Hiway Gateway Specification and Technical Data Introduction This publication defines the significant

More information