1 Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description Approvals Features and Benefits Selection Product Selection Technical Data and Specifications Dimensions CA070001E March
2 .2 Limit Switches The Cost-Effective Solution for Highly Accurate Switching Applications Product Description from Eaton s electrical business provide high-accuracy switching at an affordable price. A variety of standard features, such as current capacity, operating force, travel characteristics and actuators, lets you custom fit the switch to your application. The switches are available in their compact basic form, or enclosed in a rugged metal housing. Approvals UL Recognized CSA Certified Contents Description Page Selection Product Selection Technical Data and Specifications Dimensions Features and Benefits Compact housings are ideal for use where space is restricted Precision, snap-action operators provide accurate repeatability of electrical and mechanical operating characteristics High current capacity (up to A) allows power load switching and motor handling capability Enclosed booted versions shield actuators from debris Wide variety of operators available Compact size fits where you need it Basic or enclosed switch Rugged die-cast aluminum enclosure or screw terminals 1/2" NPT conduit fitting Unless otherwise noted, the products contained in this document are not designed or intended for use in human safety applications. 2 CA070001E March 09
3 Limit Switches.2 Selection Product Selection Basic Switches E47BMS01 E47BMS02 E47BMS0 E47BMS04 Description E47 = Precision switch Amperes B = 1A C = A Pin Plunger Straight Plunger Extended Plunger E 4 7 B M S V Type L = Enclosed M = Basic Type L = S = Screw T = Spade 1A Screw E47BMS01-V E47BML01-V A Screw E47CMS01-V E47CML01-V 1A Screw E47BMS02-V E47BML02-V A Screw E47CMS02-V E47CML02-V 1A Screw E47BMS0-V E47BML0-V Extended Straight Plunger 1A Screw E47BMS04-V E47BMT04-V E47BML04-V A Screw E47CMS04-V E47CML04-V 01 = Pin plunger 02 = Straight plunger 0 = Extended plunger 04 = Extended straight plunger 0 = Plunger actuator 0 = Booted plunger 07 = Roller plunger 08 = Booted roller plunger 10 = Roller plunger 11 = Cross roller plunger 12 = Booted cross roller plunger 14 = Booted wobble = Standard lever E47BMS10 E47BMS11 E47BMS Description V = Vehicle control Product Type 21 = Reversed lever 22 = Straight lever 2 = Integral leaf 0 = Roller lever 1 = One-way roller 2 = Roller lever = Booted roller lever 4 = One-way roller = Booted one-way roller 40 = Adjustable roller 41 = Reversed roller lever 42 = Extended roller lever 4 = Extended adjustable roller Roller Plunger Cross Roller Plunger Standard Lever 1A Screw E47BMS10-V E47BML10-V A Screw E47CMS10-V 1A Screw E47BMS11-V E47BML11-V A Screw E47CMS11-V 1A Screw E47BMS-V E47BML-V Notes Contact Eaton s Cutler-Hammer Sensor Applications Department at for approval status. With space lugs. CA070001E March 09
4 .2 Limit Switches Basic Switches, Continued E47BMS21 E47BMS22 E47BMS2 E47BMS0 E47BMS1 Reversed Lever Amperes Type Straight Lever Integral Leaf Roller Lever One-Way Roller 1A Screw E47BMS21-V E47BML21-V Spade E47BMT21-V 1A Screw E47BMS22-V E47BML22-V A Screw E47CMS22-V 1A Screw E47BMS2-V E47BML2-V A Screw E47CMS2-V 1A Screw E47BMS0-V E47BML0-V Spade E47BMT0-V A Screw E47CMS0-V Spade E47CMT0-V 1A Screw E47BMS1-V E47BML1-V E47BMS40 E47BMS41 E47BMS42 E47BMS4 Basic Switch Accessories E47PA1 E47PA2 Adjustable Roller Reversed Roller Lever Extended Roller Lever 1A Screw E47BMS40-V E47BML40-V 1A Screw E47BMS41-V E47BML41-V 1A Screw E47BMS42-V E47BML42-V A Screw E47CMS42-V Extended Adjustable Roller 1A Screw E47BMS4-V E47BML4-V Wire Covers for Basic Switches Description wire cover with 4 conduit interface wire cover with 90 conduit interface E47PA1-V E47PA2-V 4 CA070001E March 09
5 Limit Switches.2 Enclosed Switches E47BLS0 E47BLS0 E47BLS07 E47BLS08 E47BLS11 E47BLS12 Plunger Actuator Booted Plunger Roller Plunger Booted Roller Plunger 1A Screw E47BLS0-V A Screw E47CLS0-V 1A Screw E47BLS0-V 1A Screw E47BLS07-V 1A Screw E47BLS08-V Roller Plunger Cross Roller Unit 1A Screw E47BLS11-V Booted Roller Plunger Cross Roller Unit 1A Screw E47BLS12-V E47BLS14 E47BLS2 E47BLS E47BLS4 E47BLS Booted Wobble Roller Lever Booted Roller Lever One-Way Roller 1A Screw E47BLS14-V 1A Screw E47BLS2-V A Screw E47CLS2-V 1A Screw E47BLS-V 1A Screw E47BLS4-V Booted One-Way Roller 1A Screw E47BLS-V Notes Contact Eaton s Cutler-Hammer Sensor Applications Department at for approval status. CA070001E March 09
6 .2 Limit Switches Technical Data and Specifications General Specifications Item Operating speed Configuration Note: Spade type not shown, available on some models. Contact Configuration Specification 0.01m/second to 1m/second Operating frequency Mechanical 1 Operations/minute Electrical Operations/minute Mechanical life,000,000 Operations minimum Electrical life 00,000 Operations minimum Contact resistance 1m Ohms maximum, initial Insulation resistance 100m Ohms 00 Vdc Dielectric strength Between non-current carrying parts 1000 Vac, 0/0 Hz for 1 minute Between current carrying parts and ground 00 Vac, 0/0 Hz for 1 minute Ambient operating temperature Basic 1 to 17 F ( 2 to 80 C) Enclosed to 17 F ( 1 to 80 C) Environmental rating enclosed, booted NEMA 1 Mounting centers 1.0 in (2.4 mm), #8 screw size screws Bottom facing M4 x 0.7 (8 2) Screws with cup washers will accept AWG (2. sq. mm maximum) maximum torque: 10 in-lbs. Threaded bushing 1/2 in Material of construction Mineral filled phenolic Enclosure rating Aluminum die casting (ADC-/A80); Seal boot: nitrile butyl rubber (NBR) Conduit fitting on enclosed type 1/2 inch NPT Screw Type Form C Precision Snap Action Type Operating Characteristics Definitions Code Description OF Operating force RF Return force PT Pre-travel OT Overtravel MD Movement differential FP Free position OP Operating position CA070001E March 09
7 Limit Switches.2 Product Specifications s E47 01-V E47 02-V E47 0-V E47 04-V E47 0-V E47 0-V E47 07-V Operating force (max.) 12. oz (0g) 12. oz (0g) 12. oz (0g) 12. oz (0g) oz ( 0g) oz (800g) oz ( 0g) Return force (min.) 4.02 oz (114g) 8.4 oz (240g) 4.02 oz (114g) Return force (max.) 4.02 oz (114g) 4.02 oz (114g) 4.02 oz (114g) 4.02 oz (114g) Pre-travel (max.) 0.01 in (0.4 mm) 0.01 in (0.4 mm) 0.01 in (0.4 mm) 0.01 in (0.4 mm) 0.01 in (0.4 mm) in (2.0 mm) 0.02 in (0. mm) Overtravel (max.) 0.00 in (0.1 mm) 0.0 in (1. mm) 0.0 in (1. mm) in (. mm) in (. mm) in (.0 mm) in (. mm) Movement differential (max.) in (0.0 mm) in (0.0 mm) in (0.0 mm) in (0.0 mm) in (0.0 mm) in (0.1 mm) in (0.0 mm) Free position (max.) Operating position (max.) 0.2 in (1.9 mm) 0.84 in (2 mm) 1.11 in (28.2 mm) 0.88 in (21.8 mm) 04 in (8.2 mm) 1.80 in (4.8 mm) 1.97 in (49.7 mm) s E47 08-V E47 10-V E47 11-V E47 11-V Cross Roller Unit E47 12-V Cross Roller Unit E47 14-V E47 -V Operating force (max.) 17.4 oz (00g) 12. oz (0g) 12. oz (0g) oz 17.4 oz (00g) 2.11 oz (0g). oz (100g) ( 0g) Return force (min.). oz (100g) 4.02 oz (114g). oz (100g) 0.88 oz (2g) 0.99 oz (28g) Return force (max.) 4.02 oz (114g) 4.02 oz (114g) Pre-travel (max.) 0.09 in (1.0 mm) 0.01 in (0.4 mm) 0.01 in (0.4 mm) 0.02 in (0. mm) 0.09 in (1.0 mm) 0. in (1.2 mm) in (.0 mm) Overtravel (max.) 0.18 in (. mm) 0.14 in (.8 mm) 0.14 in (.8 mm) in (. mm) 0.18 in (. mm) 0.1 in (8.0 mm) in (2.0 mm) Movement differential (max.) 0.00 in (0.12 mm) in (0.0 mm) in (0.0 mm) in (0.0 mm) 0.00 in (0.12 mm) 0.09 in (1.0 mm) 0.09 in (1.0 mm) Free position (max.) 0.97 in (24.8 mm) Operating position (max.) 1.97 in (49.7 mm) 1.1 in (.4 mm) 1.1 in (.4 mm) 1.97 in (49.7 mm) 1.97 in (49.7 mm) in (19 mm) s E47 21-V E47 22-V E47 2-V E47 0-V E47 1-V E47 2-V E47 -V Operating force (max.).29 oz (10g) 2.47 oz (70g) 0. oz (10g).4 oz (10g).4 oz (10g).1 oz (70g) 22.7 oz (40g) Return force (min.) 0.49 oz (14g) 0.10 oz (.0g) 1.48 oz (42g) 1.48 oz (42g).0 oz (1700g) 8.11 oz (g) Return force (max.) 0.49 oz (14g) Pre-travel (max.) 0.1 in (4 mm) 0.94 in (10 mm) in (.0 mm) 0.10 in (2.7 mm) 0.10 in (2.7 mm) 0.17 in (4.0 mm) in (.0 mm) Overtravel (max.) 0.0 in (1. mm) 0.2 in (. mm) 0.22 in (. mm) in (2.4 mm) in (2.4 mm) 0.2 in (.0 mm) 0.2 in (.0 mm) Movement differential (max.) 0.01 in (1. mm) 0.01 in (1. mm) in (.0 mm) 0.02 in (0. mm) 0.02 in (0. mm) 0.01 in (0.4 mm) 0.01 in (0.4 mm) Free position (max.) 0.81 in (. mm) 1.11 in (28.2 mm) 1.28 in (2. mm) in (4. mm) Operating position (max.) 0.8 in (17.4 mm) in (19 mm) in (19.0 mm) in (0.2 mm) 1.97 in (4.1 mm) s E47 4-V E47 -V E47 40-V E47 41-V E47 42-V E47 4-V Operating force (max.).1 oz (70g) 22.7 oz (40g) 17.4 oz (00g).29 oz (10g).4 oz (10g) 21.1 oz (00g) Return force (min.).0 oz (170g) 8.11 oz (g).0 oz (170g) 0.78 oz (22g) 10.8 oz (00g) Return force (max.) 0.49 oz (14g) Pre-travel (max.) 0.17 in (4.0 mm) in (.0 mm) in (.0 mm) 0.1 in (4 mm) 0.28 in (7.1 mm) in (.0 mm) Overtravel (max.) 0.2 in (.0 mm) 0.2 in (.0 mm) 0. in (12.7 mm) 0.0 in (1. mm) 0.1 in (4 mm) 0.2 in (.0 mm) Movement differential (max.) 0.01 in (0.4 mm) 0.01 in (0.4 mm) in (2.2 mm) 0.01 in (1. mm) 0.04 in (1.02 mm) in (2.0 mm) Free position (max.) 1.72 in (44. mm) 1.22 in (1.8 mm) 1.47 in (. mm) 1.14 in (41 mm) Operating position (max.) 91 in (40.4 mm) 1.12 in (28. mm) in (0.2 mm) 91 in (40.4 mm) CA070001E March
8 .2 Limit Switches Ratings Notes Inductive load has a power factor of 0.04 minimum (AC) and a time constant of 7 m/second (DC). Lamp load has an inrush current of times steady-state current. Dimensions Approximate Dimensions in Inches (mm) E47 01-V E47 02-V E47 0-V Non-inductive Load (A) Inductive Load (A) Resistive Load Lamp Load Inductive Load Motor Load Inrush Current (A) Model Rated Voltage (V) NC and NO NC NO NC and NO NC NO NC NO 1A A 12 Vac Vac 00 Vac 8 Vdc 14 Vdc 0 Vdc 12 Vdc Vdc 12 Vac Vac 00 Vac 8 Vdc 14 Vdc 0 Vdc 12 Vdc Vdc (2) E47 04-V E47 0-V E47 0-V Max. 1 Max. 0 Max. 0 Max. 8 CA070001E March 09
9 Limit Switches.2 Approximate Dimensions in Inches (mm) E47 07-V E47 08-V E47 10-V E47 11-V E47 11-V Cross Roller Unit E47 12-V Cross Roller Unit E47 14-V 0.2 [.] Dia. 0.7 [9.] 2-M4.0 x [2] 1.00 [2.] 1.00 [2.4] 1.00 [2.4] 0.9 [24.] E47 -V E47 21-V E47 22-V PT.7 [8.].91 [10] 0.7 [17] 0.08 [2.1] CA070001E March
10 .2 Limit Switches Approximate Dimensions in Inches (mm) E47 2-V E47 0-V E47 1-V E47 2-V E47 -V E47 4-V E47 -V E47 40-V E47 41-V E47 42-V 10 CA070001E March 09
11 Limit Switches.2 Approximate Dimensions in Inches (mm) E47 4-V E47PA1-V ø E47PA2-V ø A B 12 A B CA070001E March
12 Eaton Corporation is a diversified power management company ranked among the largest Fortune 00 companies. The electrical group is Eaton s largest division and is a global leader in electrical control, power distribution, power quality, automation, and monitoring products and services. Eaton s global electrical brands, including Cutler-Hammer, MGE Office Protection Systems, Powerware, Holec, MEM, Santak and Moeller, provide customer-driven PowerChain Management solutions to serve the power system needs of the industrial, institutional, government, utility, commercial, residential, IT, mission critical and OEM markets worldwide. PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle. With Eaton s distribution, generation and power quality equipment; full-scale engineering services; and information management systems, the power system is positioned to deliver powerful results: greater reliability, operating cost efficiencies, effective use of capital, enhanced safety, and risk mitigation. Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 1108 United States 877-ETN-CARE ( ) Eaton.com 09 Eaton Corporation All Rights Reserved Printed in USA Publication No. CA070001E / Z81 March 09 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.
PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)
PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and
More informationModel Number Structure
Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via
More informationSafety Interlock Switches
r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables
More information10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC
Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High
More informationEPM Series Reversing Electric Actuators
EPM Series Reversing Electric Actuators Innovative Quarter-Turn Actuators that Look the Same on the Outside with the Hayward Difference on the INSIDE! Overview On/Off and Proportional Control Models Designed
More informationType Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder
A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with
More informationEmergency Stop Devices
New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com
More informationDefinite Purpose Contactors 1, 2 and 3 pole Type GDP
Definite Purpose Contactors 1, 2 and 3 pole Type l Definite Purpose Contactors l Switching up to 100A resistive, 90A inductive l Line Voltage up to 600VAC on most sizes l Control voltage up to 480VAC l
More informationGeneral Purpose High Power PCB Relays
T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL
More informationPlug-in/solder terminals with LED indicator
General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole
More informationGeneral-purpose Relay
General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals
More informationDual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series
Dual Modular Safety Shutoff Valves with Proof of Closure Option DMV eco Series DMV-D eco Series DMV-DLE eco Series Two normally closed safety shutoff valves in one housing; each with the following approvals.
More information6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description
.1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................
More informationMX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)
MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system
More informationData Sheet for Precision Potentiometer
AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn
More informationData Sheet for Precision Potentiometer
The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19
More informationPower Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops
Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated
More informationSupplementary protector S 200 MR for ring-tongue applications acc. to UL 1077
Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC
More informationProduct Guide LED OBSTRUCTION LIGHTS
Product Guide LED OBSTRUCTION LIGHTS Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO Aerodromes Design Manual, Chapter 18 Canadian
More informationMounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B
A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles
More informationEmergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction
Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.
More informationL-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights
L-864 L-865 / L-864 L-810 L-810 Vigilant Series LED Based Obstruction Lights Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO
More informationDJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing
Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated 02.17312.21
More informationSmallest Connector with Removable Contacts
1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative
More informationB-Series Switches Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage treatment
More informationCASM electric cylinders The modular electric cylinder system
CASM electric cylinders The modular electric cylinder system CASM electric cylinders are ideally suited to performing fast and powerful linear movements. Unlike pneumatic or hydraulic cylinders, CASM electric
More informationGround Clamps Cable Tray
COMMERCIAL AND INDUSTRIAL FITTINGS: GROUNDING FITTINGS AND SOLDERLESS CONNECTORS Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both
More informationPGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI
PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore
More informationCASM electric cylinders
CASM electric cylinders 2 The modular electric cylinder system CASM electric cylinders are ideally suited to performing fast and powerful linear movements. Unlike pneumatic or hydraulic cylinders, CASM
More informationRussellstoll. Electrical Interconnection Systems. Dura-Gard Nonmetallic Waterproof Connections. The Next Generation: Dura-Gard
Dura-Gard Washdown Duty, Chemical, Outdoor, Industrial and Marine Use Nonmetallic Plugs, Connectors Receptacles and Inlets 20, 30 and, Maximum 600 VAC/250 VDC The Next Generation: Dura-Gard Severe environments
More informationLOCAL DISCONNECT SWITCHES Manual Motor Controllers
LOCAL DISCONNECT SWITCHES Manual Motor Controllers 1 2 Ensto Manufacturer of electrical components and systems This brochure presents the economical, versatile and reliable Ensto Origin manual motor controllers
More informationNIBCO PNEUMATIC ACTUATORS
ACT-0718 ACTUATORS AND CONTROLS FOR METAL & CHEMTROL VALVES Effective July 2, 2018 Supercedes ACT-0117 dated January 2, 2017 Suggested List Prices Subject to Change Without Notice. NIBCO PNEUMATIC ACTUATORS
More informationPilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)
(general purpose valve) ADK11/ADK12 Series NC (normally closed) type, NO (normally open) type Port size: Rc1/4 to Rc1 Diaphragm structure Excluding ADK12 JIS symbol ADK11: NC (normally closed) type OUT
More informationSafeSite. Series LED Based Signaling for Hazardous Locations
SafeSite Series LED Based Signaling for Hazardous Locations Index 02 SafeSite L-864 Red LED Beacon 03 SafeSite LED Based L-864/L-865 Flashing Dual (White/Red) Strobe 04 SafeSite L-810 Red LED Obstruction
More informationElectric Smoke Damper Actuators
Bulletin Issue Date May 20, 2004 Electric Smoke Damper Actuators The Modulating Electric Smoke Damper Actuators are oil immersed, spring return, linkage coupled actuator for modulating damper control designed
More informationHEATER POWER CONTROLLER
HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL
More information630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.
SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and
More informationCASM electric cylinders
CASM electric cylinders 2 The modular electric cylinder system CASM electric cylinders are ideally suited to performing fast and powerful linear movements. Unlike pneumatic or hydraulic cylinders, CASM
More informationPower Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -
SVL Essential DIN Rail Series SVL Series power supplies are perfect for high volume, controlled environment applications where essential features are the only requirement. When space inside an enclosure
More informationGeneral-Use Auto-Tuning HPX-T Series
General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display
More informationZinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable
Zinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable Type FC Set Screw To terminate regular wall steel or aluminum flexible conduit to a 1/2 knockout in a dry location
More informationB-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic
B-Series Switches Pressure, Differential Pressure, FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills
More informationDUPLEX STRAINERS 800-KECKLEY ( ) BULLETIN NO / FAX: 847/ WEB SITE:
BULLETIN NO. 9400- DUPLEX STRAINERS 800-KECKLEY (800-2-9) 847/674-8422 FAX: 847/674-206 E-MAIL: SALES@KECKLEY.COM WEB SITE: WWW.KECKLEY.COM NO QUESTION. WE HAVE THE ANSWERS. Shown with Optional Differential
More informationUniversal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W
isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP
More informationReferences. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_156_a_2_cat Direct
More informationCover, 1 Gang; Malleable Iron; Zinc Electroplated Dichromate Aluminum Polymer Enamel; Box Mounting; Appleton[R] Brand; FS Model; With Square Handle
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 K1VS 1G Mall WP SW Cover Appleton/Oz Gedney Catalog Number Manufacturer Weight per unit Product Category Features Device
More informationNexus Standard Glove Box System
NOW CONFORMS TO UL AND CSA STANDARDS FOR LABORATORY EQUIPMENT Nexus Standard Glove Box System Vacuum Atmospheres Company Vacuum Atmospheres Company 4652 W. Rosecrans Ave. East Coast Office P.O. Box 1043
More informationSingle, oversized roller compresses a low friction hose through a full 360-degree rotation
Graco EP Series Hose Pump Technology Single, oversized roller compresses a low friction hose through a full 360-degree rotation More flow per revolution than conventional designs One hose compression per
More informationDialight LED High Bay - High Output. Technical Specification Sheet - Americas
Dialight LED High Bay - High Output Technical Specification Sheet - Americas NOVEMBER 2018 High Bay - High Output High Bay Standard Corded Models Vigilant LED High Bay - High Output Standard Models Certifications
More informationSIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationSystem pro M compact Miniature Circuit Breaker S 200 U and S 200 UP
Data Sheet System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP 2CDC021316F0004 2CDC021320F0004 The S 200 U and S 200 UP ranges are miniature circuit breakers conforming to UL, CS and IEC
More informationWASHGUARD. More Than Just a Motor Company WASHDOWN DUTY PT PRODUCTS ELECTRIC MOTORS, GEAR REDUCERS, AC & DC DRIVES. Bulletin 1500
A REGAL-BELOIT COMPANY More Than Just a Motor Company WASHGUARD WASHDOWN DUTY PT PRODUCTS ELECTRIC MOTORS, GEAR REDUCERS, AC & DC DRIVES Bulletin 1500 WASHGUARD WHITE EPOXY Enhanced Performance in Wet,
More informationVigilant LED High Bay - CE Technical Specifications
Vigilant LED High Bay - CE Technical Specifications 10 year warranty Ratings and Certifications L70 >150,000 hours @ 25 C ambient CE / ENEC / RCM / UL IP66 IK05 (acrylic lens) / IK06 (glass lens) / IK10
More informationCEELOK FAS-T CONNECTORS
CEELOK FAS-T CONNECTORS Small Form Factor, Field Terminable Connectors CeeLok FAS-T connectors ofer a small form factor, ield terminable I/O connector capable of 0 Gb/s Ethernet. Crimpsnap contacts enable
More informationAutomated Tiki Torch Installation Instructions
Automated Tiki Torch Installation Instructions Automated Tiki Torch with Poles (Exploded View) 14 Automated Tiki Head 6 8 Tiki Pole (Powder Coated Aluminum or Faux Bamboo Pole) 12 Base Pole (Powder Coated
More informationXENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL
TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger
More informationInsulated Scissors. Handles made with shock-proof plastic. Length Blade Std. Part No. Type mm shape Pk.
Cutting Tools Cable Cutter - For copper and aluminum cables only. Extremely high cutting capacity with adjustable screw joint. for cable Length Std. Part No Type Ømm mm 2 AWG mm Pk. AP1017 N 15 50 1/0
More informationFILTERED FAN PACKAGES
FILTERED FAN PACKAGES PLASTIC & METAL FILTERED FANS EFFICIENT, QUITE BALL BEARING MOTORS NEMA TYPE 1 AND 3R ALL KITS INCLUDE GASKETS, HARDWARE, AND TEMPLATE UL LISTED Plastic FILTER FAN PACKAGES Injection
More informationElectrical Specifications. Dimensions (inches)
Page 7203 Electrical Specifications Valve Position Control 0.1 angular degree resolution Flow Control ± 1% of flow reading over a turndown of 20: 1 ir/fuel Ratio Control ± 2% with turndown of 20: 1 Power
More informationDUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076
Distributed By: M&M Control Service, Inc. www.mmcontrol.com/keckley.php 800-876-006 847-6-066 BULLETIN NO. 9400- DUPLEX STRAINERS Shown with Optional Differential Pressure Indicator KECKLEY COMPANY 400
More informationSolutions for Original Equipment Manufacturers (OEM) Connecting Power to Your World TM
Solutions for Original Equipment Manufacturers (OEM) Connecting Power to Your World TM The Right Fit At BURNDY, we pride ourselves on developing solutions. In fact, we thrive on challenge. When our customers
More informationElectrical Specifications. Dimensions (inches)
Page 7203 Electrical Specifications Valve Position Control 0.1 angular degree resolution Flow Control ± 1% of flow reading over a turndown of 20: 1 ir/fuel Ratio Control ± 2% with turndown of 20: 1 Power
More informationSection B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1
Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe
More informationAISI 316L PERFORMANCE RANGE INSTALLATION AND USE
CP-ST Stainless steel centrifugal pumps CP-ST4 Pump body: stainless steel AISI 304 Impeller: stainless steel AISI 304 Shaft: stainless steel AISI 431 CP-ST6 Pump body: stainless steel AISI 316L Impeller:
More informationSpecifications. According to CEC Rule Please Note
T& Fittings rmoured able and Flexible Metal onduit Fittings Specifications rmoured able (Type 90) Ref. E Rule 12-600 The anadian Electric ode 2012 Part I defines type armoured cable as, fabricated assembly
More informationElectronic Temperature Controls
ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple
More informationNH MULTIBLOC fuse-switchdisconnector. terminal version reference no.
NH fuse-switch-disconnector NH fuse-switchdisconnector ~ 690V screw fixing of disconnectors onto plates size rated current in A no. of poles terminal version art. group 00 160 1 screw M8 both sides F229292
More informationFIBER OPTIC CLOSURES
FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC
More informationOperational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue
Complete Assemblies Knob-type Selector Switch Install in 22-mm dia. or 25-mm dia. Panel Cutout H Illuminated and Non-illuminated models H Locking lever ensures easy mounting and removal of switch unit
More informationSection B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1
Parts B - Section B Parts. Introduction To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe
More informationMORIN B AND C SERIES ACTUATORS
MORIN B AND C SERIES ACTUATORS B series - Ductile iron w/ stainless steel cylinders, C series - Ductile iron w/ carbon steel cylinders Spring return and double acting actuators Quarter-turn output torques
More informationAmbient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage
SSR Power Controller SSR 1 SSR 2 SSR 3 Phase Single 2 Leg Switching 3 Phase DIN Rail/Panel Mounting Both Both Both Cooling Fan Optional Optional Optional Control MethodZero Cross Trigger / high isolation
More informationSection 11 Workstation Components
1 Section Quick and easy access to parts is made possible by the wide variety of trays, bins, and framing components available from Bosch. Individual workstation grab trays, containers, and ledges place
More informationBourdon Tube Pressure Switches
Bourdon Tube es Ranges to 8000 psi (55. bar) FEATURES Visible calibrated dial On/off indication (except hermetically sealed snap switch models) Adjustable or fixed deadband SPT snap-action, hermetically
More informationBig SHOT III Hybridization Oven
Big SHOT III Hybridization Oven Models 230402 and 230402-2 Whether you are working with Northern Blots, Southern Blots, Microarrays or another application that requires incubation, you will find the Big
More informationMODEL CFD Forward Curved Belt Driven Inline Duct Blower
Forward Curved Belt Driven Inline Duct Blower Model Overview S&P s Forward Curved Belt Driven Inline Duct Blowers are designed for supply, exhaust or ducted return applications. The CFD is an economical
More informationstyle vision & quarter turns quarter turns section section INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS
quarter turns vision & style quarter turns INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS WE RE CHANGING THE FUTURE EBERHARD INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS 3 quarter turns No. 626-PK Patent Pending
More informationDuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications
DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 Features & Benefits 10 year warranty L70 rated for >100,000
More informationMolded High-Voltage Bushing Wells
66-10 Molded High-voltage Bushing Wells Howard Industries Components Division Molded High-Voltage Bushing Wells Catalog Section 66-10 INTRODUCTION Howard Industries molded high-voltage bushing wells are
More informationTOKISTAR. Exhibitor TOKISTAR LIGHTING
TOKISTAR Exhibitor TOKISTAR LIGHTING Exhibitor TM T okistar Exhibitor Series is a wet-location festoon lighting system used in amusement parks, shopping centers, street decorations and promenades. Exhibitor
More informationINSTALLATION MANUAL AND OPERATING INSTRUCTIONS. MD25-( ) Series Airspeed Indicator
INSTALLATION MANUAL AND OPERATING INSTRUCTIONS MD25-( ) Series Airspeed Indicator REV. C July 14, 2011 Manual Number 9017051 Mid-Continent Instruments and Avionics 9400 E. 34 th Street N., Wichita, KS
More informationT&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings
T& Fittings Liquidtight Flexible Nonmetallic onduit Fittings Specifications Type onduit Fittings Series 6302 Liquidtight Flexible Nonmetallic onduit Fittings pplication To provide a liquidtight, dustight
More informationULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES
ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES UPS MIL-SPEC COMPLIANT 1-5 KVA 1-5 U UNIVERSAL 120/240 VAC PFC INPUT SNMP COMMUNICATIONS WHEN EVERY POUND COUNTS! APPLICATIONS Shelters Tactical Systems Shipboard
More information10260 Series Actuators Model Selection Guide
Issue 6 Page 1 of 5 2 Series Actuators Model Selection Guide Instructions Select the desired key number. The arrow to the right marks the selection available. Make one selection each from Table I thru
More informationPN 3000 Series Fail Closed Pneumatic Actuators
PN 3000 Series Fail Closed Pneumatic Description A of compact linear actuators having 5 diaphragm sizes for matching the requirements of 1/2" to 4" Spira-Trol valves at various differential pressures.
More informationLSC19 Lighting Cable Assemblies and Connectors
PowerFLEX Cable Assemblies PowerPARTS Wiring Devices ISO 9001:2008 LSC19 Lighting Cable Assemblies and Connectors PowerFLEX and PowerPARTS Introducing a new generation of Lex Products 19 pin, 6-circuit
More informationTrapped Key Transfer System SHGV SVM SVE
Trapped Key Transfer System SHGV SVM SVE Description Area of application Cost Savings The SHGV key transfer system occurs mainly in more complex manufacturing systems and equipment. It is especially suitable
More informationSynflex. Mini Catalog
Synflex Mini Catalog Table of Contents Hose Selection Chart Core 5 Hoses (Application/Product) 2 3R30, 3130, 3580, 30CT, 3R80 Core 5 Hoses (Product) 2 3R30, 3130, 3580, 30CT, 3R80 Hose 3R30 Low Pressure
More informationCONTENTS. Gold Bond Fasteners Bolts 1 Clamps 3 Nuts 4 Washers 5. Hoist Rings Center Pull 6 Side Pull 7. Socket Head Stripper Bolts Inch 8 Metric 9
CONTENTS PAGE NUMBER Gold Bond Fasteners Bolts 1 Clamps 3 Nuts 4 Washers 5 Hoist Rings Center Pull 6 Side Pull 7 Socket Head Stripper Bolts Inch 8 Metric 9 Punch Holder Shanks 10 Roller Stock Guides 11
More informationModel Number Structure
The reliable choice for Hockey-puck-style Solid State Relays. Available in a wide Range of Currents and Voltage. (5 to 90A, max 660 VAC) All models feature the same compact dimensions to provide a uniform
More informationDistinctive Characteristics
Distinctive Characteristics Base of heat resistant resin meets ULV-0 flammability rating. Maximized voltage capability of V allows use in medium source applications and increases operating life. Award-winning
More informationFLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing
FLFE..L FLF..L - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time Ex e terminal board housing Simplified maintenance 4 Joule shock resistant borosilicate glass White painted
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 480W Single Output Industrial DIN RAIL with FC Function SECIFICATION MODEL
More informationIndustrial Specification Grade Straight Blade Receptacles. Duplex and Single Receptacles
Industrial Specification rade 2 Pole, 3 ire rounding Duplex and Single A-5 STRAIHT BLADE TESTIN & CODE Spec. C-596 (file no. 15058). C22.2 no. 42, CSA (file no. 6233-01). 2.37" (60.2mm) 1.31" (33.3mm)
More informationConservatory awning W8 Description
1 3 4 Application Large-area external sun shading system for shading glazed conservatories, patio roofs and pergolas with flat pitch roofs. Function principle: tensioning system via toothed belt with steel
More informationINSTRUCTIONS INSTALLATION UNIVERSAL SERIES PATIO AWNING HARDWARE , , ,
RECORD THIS INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number Hardware Model Number Hardware Serial Number Date Purchased Retailer / Qualified Installer INSTALLATION INSTRUCTIONS UNIVERSAL SERIES
More informationCEILING FANS. Included Features
Product No: E-CF130 BS Three curved blades Dual-Mount feature SW46 Wall control Fan span: 30" Overall fan height: 9.5" / 13.3" Blade to ceiling height: 8.1" / 11.9" Housing width: 7.3" Canopy width: 5.1"
More informationTip-Over Switches - Non Mercury Contacts
Tip-Over Switches - Non Mercury Contacts SWITCH OPERATION CW172-1 CW1740-1 CW12-0 Tip-over switches are designed to switch on/off when tilted from the vertical position. CW12-0 CW12-1 0.2 ± 10 Ω at Vdc
More information