PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Size: px
Start display at page:

Download "PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)"

Transcription

1 PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and air conditioning), and many other applications. A variety of contact forms: SPDT, SPST-NO, and SPST-NC. UL Class B and F insulation, open and sealed versions, and dust cover available. Solder-plated terminals for better solderability. RC Ordering Information Contact Standard Class B Class F form Open Fully sealed Open Fully sealed Open Fully sealed SPST-NO -P-US -4P-US -P-BI-US -4P-BI-US -P-CF-US -4P-CF-US SPST-NC -0P-US -04P-US -0P-BI-US -04P-BI-US -0P-CF-US -04P-CF-US SPDT -P-US -4-US -P-BI-US -4P-BI-US -P-CF-US -4P-CF-US Note:. The contacts described above are AgCdO.. When ordering, add the rated coil voltage to the model number. Example: -P-US VDC Rated coil voltage Model Number Legend VDC Number of Poles : pole. Contact Form None:SPDT : SPST-NO 0: SPST-NC. Contact Types : Standard 4. Enclosure Ratings : Open 4: Fully sealed. Terminals P: Straight PCB. UL Insulation Rate None:Standard Bl: Class B insulation CF: Class F insulation 7. Approved Standards US: UL/CSA certified 8. Rated Coil Voltage,, 9,,, 8, 4, 48, 0 VDC Accessories (Order Separately) Dust cover -R99-C0

2 Specifications Coil Ratings Rated voltage VDC VDC 9 VDC VDC VDC 8 VDC 4 VDC 48 VDC 0 VDC Rated current 8 ma 0 ma 9 ma 77 ma 9 ma 47 ma ma 9 ma 9 ma Coil resistance 7! 40! 97!!! 80! 0!,480!,400! Must operate voltage Must release voltage Max. permissible voltage Power consumption 7% max. of rated voltage 0% min. of rated voltage 0% of rated voltage Approx. 900 mw Note: The rated current and coil resistance are measured at a coil temperature of "C with tolerances of #0%. Contact Ratings Item SPST-NO SPST-NC SPDT Load Resistive load (cos$ = ) Rated load Contact material 0 A at 0 VAC; 0 A at 8 VDC AgCdO A at 0 VAC; 0 A at 8 VDC Rated carry current 0 A A 0 A/0 A* Max. switching voltage 0 VAC, 8 VDC 0 A/0 A* at 0 VAC; 0 A/0 A* at 8 VDC Max. switching current AC:0A,DC:0A AC:A,DC:0A AC: 0 A/0 A, DC: 0 A/0 A* Max. switching power 7,00 VA, 0 W,70 VA, 80 W,000/,00 VA, 0/80 W* Min. permissible load Note: *NO contact/nc contact Characteristics Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric strength 00 ma at VDC 0 m! max. ms max. 0 ms max. Mechanical:8,000 operations/hr Electrical:,800 operations/hr (under rated load) 0 M! min. (at 00 VDC),00 VAC, 0/0 Hz for min Vibration resistance Destruction:0 to Hz,.-mm double amplitude for hours Malfunction:0 to Hz,.-mm double amplitude for minutes Shock resistance Destruction:,000m/s Malfunction: 00 m/s Life expectancy Mechanical: 0,000,000 operation min. (at 8,000 operations/hr) Electrical: See Engineering Data. Ambient temperature Standard types: --"C to 70"C (with no icing) Class B insulation types: --"C to 8"C (with no icing) Class F insulation types: --"C to 0"C (with no icing) Ambient humidity Operating: 4% to 8% Weight Note: The data shown above are initial values. Approx. 0 g (-P), approx. 0 g (-4P)

3 Approved Standards UL (File No. E44) Type Contact form Coil ratings UL08-recognized -P-US SPST-NO to0vdc A, VAC (inductive load) 0 A, 0 VAC (inductive load) A, 8 VDC (resistive load) hp, VAC (motor load) hp, 0 VAC (motor load) A (,0 W), 0 VAC (tungsten load) -0P-US SPST-NC A, VAC (inductive load) 0 A, 0 VAC (inductive load) 0 A, 8 VDC (resistive load) 0. hp, VAC (motor load) 0. hp, 0 VAC (motor load) A (70 W), 0 VAC (tungsten load) -P-US SPDT NO/NC A/0 A, VAC (inductive load) 0 A/0 A, 0 VAC (inductive load) A/0 A, 8 VDC (resistive load) hp/0. hp, VAC (motor load) hp/0. hp, 0 VAC (motor load) A/ A, 0 VAC (tungsten load) CSA (File No. LR48-0) Contact ratings Type Contact form Coil ratings Contact ratings -P-US SPST-NO to0vdc A, 77 VAC (inductive load) A, VAC (inductive load) 0 A, 0 VAC (inductive load) A, 8 VDC (resistive load) hp, VAC (motor load) hp, 0 VAC (motor load) A, VAC (tungsten load) A, 0 VAC, (tungsten load) -0P-US SPST-NC A, 77 VAC (inductive load) A, VAC (inductive load) 0 A, 0 VAC (inductive load) 0 A, 8 VDC (resistive load) 0. hp, VAC (motor load) 0. hp, 0 VAC (motor load) A, VAC (tungsten load) A, 0 VAC, (tungsten load) -P-US SPDT NO/NC A/ A, 77 VAC (inductive load) A/0 A, VAC (inductive load) 0 A/0 A, 0 VAC (inductive load) A/0 A, 8 VDC (resistive load) 0. hp/0. hp, VAC (motor load) hp/0. hp, 0 VAC (motor load) A/ A, VAC (tungsten load) A/ A, 0 VAC, (tungsten load) UL87, UL 0 A, 0 VAC (inductive load) hp, VAC (motor load) hp, 0 VAC (motor load) A, 77 VAC (inductive load) A, 0 VAC (inductive load) 0. hp, VAC (motor load) 0. hp, 0 VAC (motor load) A, 77 VAC (inductive load) NO/NC 0 A/0 A, 0 VAC (inductive load) hp/0. hp, VAC (motor load) hp/0. hp, 0 VAC (motor load) A/ A, 77 VAC (inductive load)/ UL87

4 Engineering Data Maximum Switching Power SPST-NO SPST-NC SPDT Switching current (A) AC resistive load DC resistive load Switching current (A) DC resistive load AC resistive load Switching current (A) DC resistive load (NC) AC resistive load (NO) AC resistive load (NC) DC resistive load (NO) Switching voltage (V) Life Expectancy SPST-NO Life expectancy (x0 operations) 0-VAC resistive load 8-VDC resistive load Life expectancy (x0 operations) SPST-NC Switching voltage (V) 0-VAC resistive load 8-VDC resistive load Life expectancy (x0 operations) SPDT Switching voltage (V) NO contact 0-VAC resistive load NO contact 8-VDC resistive load NC contact 0-VAC resistive load Switching current (A) Switching current (A) Switching current (A) 4

5 Dimensions All units are in millimeters unless otherwise indicated. Open Types Note: -P-(BI)-US 8.7 max..9 max..#0. (.). (9.4) Three,.#0.-dia. (.8) () Two,.#0.-dia. -0P-(BI)-US 8.7 max..#0. 4 (.) (.8) Two,.#0.-dia.. (.8).9 Three,.#0.-dia. ()

6 -P-(BI)-US 8.7 max..#0. 4 (.) (.8) Two,.#0.-dia.. 7. (.8) Four,.#0.-dia. () Fully Sealed Types -4P-(BI)-US.7# (.4) Three,.#0.-dia. (4.8) Two,.#0.-dia. (4.)

7 -04P-(BI)-US.7# (.4) Three,.#0.-dia. (4.) (4.8) Two,.#0.-dia. 7

8 -4P-(BI)-US.7# (.4) Four,.#0.-dia. (4.) Dust Cover -R99-C0 (4.8) Two,.#0.-dia. Precautions Fully Sealed Relays Remove the vent hole tape seal from the cover after all soldering and cleaning have been completed to allow air circulation within fully sealed Relays. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by Cat. No. K040-E-A 8

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated

More information

Plug-in/solder terminals with LED indicator

Plug-in/solder terminals with LED indicator General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole

More information

General-purpose Relay

General-purpose Relay General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals

More information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with

More information

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external

More information

Model Number Structure

Model Number Structure Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via

More information

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles

More information

General Purpose High Power PCB Relays

General Purpose High Power PCB Relays T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL

More information

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated 02.17312.21

More information

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

Definite Purpose Contactors 1, 2 and 3 pole Type GDP Definite Purpose Contactors 1, 2 and 3 pole Type l Definite Purpose Contactors l Switching up to 100A resistive, 90A inductive l Line Voltage up to 600VAC on most sizes l Control voltage up to 480VAC l

More information

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.

More information

Limit Switches. 6.2 E47 Precision Switches

Limit Switches. 6.2 E47 Precision Switches Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description............................................. 2 Approvals..................................................... 2 Features and Benefits...........................................

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Base of heat resistant resin meets ULV-0 flammability rating. Maximized voltage capability of V allows use in medium source applications and increases operating life. Award-winning

More information

Model Number Structure

Model Number Structure The reliable choice for Hockey-puck-style Solid State Relays. Available in a wide Range of Currents and Voltage. (5 to 90A, max 660 VAC) All models feature the same compact dimensions to provide a uniform

More information

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction Pushbutton Switch Install in 22-dia. or 25-dia. Panel Cutout Easy mounting and removal of Switch Unit. Increase wiring efficiency with three-row mounting of Switch Unit. Finger protection mechanism on

More information

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series Dual Modular Safety Shutoff Valves with Proof of Closure Option DMV eco Series DMV-D eco Series DMV-DLE eco Series Two normally closed safety shutoff valves in one housing; each with the following approvals.

More information

General-Use Auto-Tuning HPX-T Series

General-Use Auto-Tuning HPX-T Series General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display

More information

Feature. Model comment JG 3NA B L - B - D3

Feature. Model comment JG 3NA B L - B - D3 Feature Device type universal nut terminals with safety protective cover -A Power Output Rated load voltage 20VAC/VAC Triac power switch Have DC-AC (DC signal to control the AC load) AC-AC (AC signal to

More information

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination. SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and

More information

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories) MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system

More information

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077 Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC

More information

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage SSR Power Controller SSR 1 SSR 2 SSR 3 Phase Single 2 Leg Switching 3 Phase DIN Rail/Panel Mounting Both Both Both Cooling Fan Optional Optional Optional Control MethodZero Cross Trigger / high isolation

More information

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP Data Sheet System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP 2CDC021316F0004 2CDC021320F0004 The S 200 U and S 200 UP ranges are miniature circuit breakers conforming to UL, CS and IEC

More information

Electronic Temperature Controls

Electronic Temperature Controls ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple

More information

Electric Smoke Damper Actuators

Electric Smoke Damper Actuators Bulletin Issue Date May 20, 2004 Electric Smoke Damper Actuators The Modulating Electric Smoke Damper Actuators are oil immersed, spring return, linkage coupled actuator for modulating damper control designed

More information

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions Analogue Timer Model H3DS-M/-S/-A H3DS-F H3DS-G Features DIN Track Mounting, Standard mm Width, Solid-state Multifunctional Timer with Smart Dial/Selector-locking Mechanism DIN Track Mounting, Standard

More information

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn

More information

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation. DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_156_a_2_cat Direct

More information

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19

More information

Operational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue

Operational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue Complete Assemblies Knob-type Selector Switch Install in 22-mm dia. or 25-mm dia. Panel Cutout H Illuminated and Non-illuminated models H Locking lever ensures easy mounting and removal of switch unit

More information

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less) (general purpose valve) ADK11/ADK12 Series NC (normally closed) type, NO (normally open) type Port size: Rc1/4 to Rc1 Diaphragm structure Excluding ADK12 JIS symbol ADK11: NC (normally closed) type OUT

More information

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2  Certifications W isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP

More information

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description .1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................

More information

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features Series AC Erie Boiler Boss Universal Control Relay General Instructions Application he AC Boiler Boss series zone control relay incorporates a double pole/double throw relay to control a circulator and

More information

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE CP-ST Stainless steel centrifugal pumps CP-ST4 Pump body: stainless steel AISI 304 Impeller: stainless steel AISI 304 Shaft: stainless steel AISI 431 CP-ST6 Pump body: stainless steel AISI 316L Impeller:

More information

Smallest Connector with Removable Contacts

Smallest Connector with Removable Contacts 1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative

More information

Fiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia.

Fiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia. s Through-beam (Sold in Pairs) E2-TL (T = 2.) M2.6 x (for M) 1. dia. 0.5 (nickelplated brass) M x Optical fiber, 2.2 dia. 0. E2-T12L 1. dia. 2. dia. (nickel-plated brass) dia. Optical fiber, 2.2 dia..2

More information

P U S H - B U T T O N S W I T C H E S

P U S H - B U T T O N S W I T C H E S PUSH-BUTTON SWITCHES Push-Button Switches SXL 7 DY 86 SCA 7 DY 88 P 76 DY Accessories 9 SP6 78 SPM 9 SP63 8 TOUCH 9 SXL5 8 RFIT 96 LITE 8 7 SWITCHES SXL TYPICAL APPLICATIONS Coffee machines, washing machines

More information

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web:  - SVL Essential DIN Rail Series SVL Series power supplies are perfect for high volume, controlled environment applications where essential features are the only requirement. When space inside an enclosure

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 480W Single Output Industrial DIN RAIL with FC Function SECIFICATION MODEL

More information

DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I

DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I MIL-DTL-38999 Series I connectors are subminiature, environmental-class connectors with high and mediumdensity insert arrangements. They are used where a quickdisconnect coupling system is required for

More information

Heating and Cooling Components. Application Selection and Cross-Reference Guide

Heating and Cooling Components. Application Selection and Cross-Reference Guide Heating and Cooling Components Application Selection and Cross-Reference Guide CONTACTORS Heat Sequencers REAYS TRANSFORMERS The Universal Choice Honeywell offers a complete range of relays, contactors

More information

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors Standard AC Standard AC Constant Speed Constant Speed Torque Brake V Series TM Series Torque Page Features and s of C-20 General Specifi cations C-28 (6 W 90 W) C-30 IP65 Terminal Box C-48 () C-61 2-Pole,

More information

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no. NH fuse-switch-disconnector NH fuse-switchdisconnector ~ 690V screw fixing of disconnectors onto plates size rated current in A no. of poles terminal version art. group 00 160 1 screw M8 both sides F229292

More information

Eclipse Hermetic Gas Boosters Series HB

Eclipse Hermetic Gas Boosters Series HB Datasheet 620 7/6/2012 Eclipse Hermetic Gas Boosters Series HB Version 1.1 Type Designations The booster is identified by catalog model, assembly number, and ordering part number. The catalog model number

More information

EC BRUSHLESS MOTOR APPLICATIONS

EC BRUSHLESS MOTOR APPLICATIONS APPLICATIONS Due to their high efficiency are often used into applications that requires low power consumption combined to high performance. Many versions are available to meet various application requirements:

More information

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W CV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications

More information

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore

More information

HEATER POWER CONTROLLER

HEATER POWER CONTROLLER HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL

More information

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Wallpack_Bulkhead_Specsheet_Industrial_Jan2018

More information

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas Dialight LED High Bay - High Output Technical Specification Sheet - Americas NOVEMBER 2018 High Bay - High Output High Bay Standard Corded Models Vigilant LED High Bay - High Output Standard Models Certifications

More information

Product Specification

Product Specification HDBNC-BH1 Jack, Right Angle Orientation, PCB Terminated HDBNC-CA Plug, Straight Orientation, Cable Terminated Other configurations available for: Vertical cable-to-board applications Through-hole, edge

More information

B-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic

B-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic B-Series Switches Pressure, Differential Pressure, FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills

More information

NIBCO PNEUMATIC ACTUATORS

NIBCO PNEUMATIC ACTUATORS ACT-0718 ACTUATORS AND CONTROLS FOR METAL & CHEMTROL VALVES Effective July 2, 2018 Supercedes ACT-0117 dated January 2, 2017 Suggested List Prices Subject to Change Without Notice. NIBCO PNEUMATIC ACTUATORS

More information

Waterproof Switches 01

Waterproof Switches 01 Waterproof Switches SL 9 BMASK 9 SA 9 RMASK 96 SLR 98 9 SWITCHES SL TYPICAL APPLICATIONS Steam cleaners S SPST, momentary or not SPST, illuminated or not DPST, momentary or not DPST, illuminated or not

More information

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection Jameco SKU Number: 2457 65W Triple Output Medical Type M T-65 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY EMC (Note 4) OTHERS NOTE OUTUT NUMBER DC VOLTAGE RATED CURRENT CURRENT

More information

B-Series Switches Temperature Switches

B-Series Switches Temperature Switches FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage treatment

More information

Jameco SKU Number:

Jameco SKU Number: Jameco SKU Number: 2105560 SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER LINE REGULATION LOAD REGULATION HOLD U

More information

Test Report: HEP

Test Report: HEP Test Report: HEP-600-24 600W Single Output Switching Power Supply DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Control Function Test Component Stress Test SAFETY

More information

DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications

DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 Features & Benefits 10 year warranty L70 rated for >100,000

More information

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger

More information

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications #

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications # DuroSite LED Floodlight - CE for Outdoor Industrial Applications # On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Floodlight_SpecSheet_CE_100-277_VAC

More information

Industrial Specification Grade Straight Blade Receptacles. Duplex and Single Receptacles

Industrial Specification Grade Straight Blade Receptacles. Duplex and Single Receptacles Industrial Specification rade 2 Pole, 3 ire rounding Duplex and Single A-5 STRAIHT BLADE TESTIN & CODE Spec. C-596 (file no. 15058). C22.2 no. 42, CSA (file no. 6233-01). 2.37" (60.2mm) 1.31" (33.3mm)

More information

600W with PFC and Parallel Function PSP-600 series

600W with PFC and Parallel Function PSP-600 series 600W with FC and arallel Function S-600 series MODEL:S-600-24 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 240 mvp-p (Max ) I/: 230VAC O/:FULL LOAD V1:

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 60W Single Output Industrial DIN Rail ower Supply DR-60 s e ries SECIFICATION

More information

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing FLFE..L FLF..L - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time Ex e terminal board housing Simplified maintenance 4 Joule shock resistant borosilicate glass White painted

More information

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area:

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands

More information

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT 120W Single Output Industrial DIN RAIL ower Supply MODEL:DRH-120-24 OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 80 mvp-p (Max ) I/: 400 VAC O/:FULL LOAD

More information

Slit Loom Installation Tool. Spools and Bags. Bulk Boxes

Slit Loom Installation Tool. Spools and Bags. Bulk Boxes Looms and Tubing Polyethylene Slit Loom Slit seam construction allows for easy wire insertion and repair, yet retains wire even when bent or twisted. Maximum temperature 93 C (200 F). Ideal for protecting

More information

Operating Manual. Revision D

Operating Manual. Revision D Operating Manual Revision D This manual was designed to guide THERMOstar users through the basic hardware features of the instrument. Headquarters Germany GmbH Hanns-Martin-Schleyer Str. 10 77656 Offenburg

More information

60W Single Output Switching Power Supply

60W Single Output Switching Power Supply 60W Single Output Switching ower Supply LC-60 series SECIFICATION MODEL LC-60-1050 LC-60-1400 LC-60-1750 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RANGE RATED OWER LINE REGULATION

More information

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns: 7-1 Section 7 Using the Illustrated List The parts lists provided in this section are organized into the following columns: Item Identifies illustrated parts that are available from Nordson Corporation.

More information

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

LOCAL DISCONNECT SWITCHES Manual Motor Controllers LOCAL DISCONNECT SWITCHES Manual Motor Controllers 1 2 Ensto Manufacturer of electrical components and systems This brochure presents the economical, versatile and reliable Ensto Origin manual motor controllers

More information

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT 15W Single Output Switching ower Supply MODEL:RS-15-15 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1:120 mvp-p (Max ) I/: 230VAC O/:FULL LOAD V1: 52 mvp-p

More information

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES UPS MIL-SPEC COMPLIANT 1-5 KVA 1-5 U UNIVERSAL 120/240 VAC PFC INPUT SNMP COMMUNICATIONS WHEN EVERY POUND COUNTS! APPLICATIONS Shelters Tactical Systems Shipboard

More information

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD 20W Single Output Switching ower Supply LV-20 series MODEL:LV-20-24 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 150 mvp-p (Max ) I/: 230VAC O/:FULL LOAD

More information

SafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1 MDTEXSSFLX001_B

SafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1  MDTEXSSFLX001_B SafeSite LED Floodlight - ATEX / IECEx for Outdoor Industrial Applications 1 www.dialight.com MDTEXSSFLX001_B On when it matters most. Products and solutions that protect your business 2 www.dialight.com

More information

Safety Interlock Switches

Safety Interlock Switches r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables

More information

50W Single Output Switching Power Supply

50W Single Output Switching Power Supply Jameco SKU Number: 540 50W Single Output Switching ower Supply LS-50 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 5) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT

More information

CABLE GRIPS CABLE GRIPS

CABLE GRIPS CABLE GRIPS STRAIN RELIEF Deluxe cord grips are woven of stainless steel mesh with an anodized aluminum body for corrosion resistance. They are offered in single/double weave construction to help absorb direct pull,

More information

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST Test Report 240W Single Switching ower Supply DESIGN VERIFY TEST Function Test Input Function Test rotection Function Test Other Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. geprufre Sicherheit 60W AC-DC Single Output Desktop G S60 s e ries SECIFICATION

More information

Trapped Key Transfer System SHGV SVM SVE

Trapped Key Transfer System SHGV SVM SVE Trapped Key Transfer System SHGV SVM SVE Description Area of application Cost Savings The SHGV key transfer system occurs mainly in more complex manufacturing systems and equipment. It is especially suitable

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Freestanding Gas Stove MODEL: PGS2005 GPEBB20R GPEBW20R Installation and Maintenance Manual Warning Maintenance products should be carried out by professional and technical personnel with relevant qualification,

More information

320W Single Output with PFC Function

320W Single Output with PFC Function Jameco SKU Number: 2102730 320W Single Output with FC Function S-320 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE

More information

NK Multi-stage submersible pumps

NK Multi-stage submersible pumps NK Multi-stage submersible pumps PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 10 m APPLICATION LIMITS Maximum liquid temperature +40 C Maximum sand content 0 g/m³ 20 m maximum immersion

More information

Electrical Specifications. Dimensions (inches)

Electrical Specifications. Dimensions (inches) Page 7203 Electrical Specifications Valve Position Control 0.1 angular degree resolution Flow Control ± 1% of flow reading over a turndown of 20: 1 ir/fuel Ratio Control ± 2% with turndown of 20: 1 Power

More information

Electrical Specifications. Dimensions (inches)

Electrical Specifications. Dimensions (inches) Page 7203 Electrical Specifications Valve Position Control 0.1 angular degree resolution Flow Control ± 1% of flow reading over a turndown of 20: 1 ir/fuel Ratio Control ± 2% with turndown of 20: 1 Power

More information

Test Report: EDR-75-12

Test Report: EDR-75-12 Test Report: EDR-75-12 75W Single Output Industrial DIN RAIL DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C.

More information

P ROTECT JUST ABOUT E VERYTHING

P ROTECT JUST ABOUT E VERYTHING P ROTECT JUST ABOUT E VERYTHING www.intermatic.com/surge T RANSIENT V OLTAGE S URGES: A GROWING P ROBLEM POWER DISTURBANCES Lightning and fluctuations in utility power (caused by grid switching, for example)

More information

Test Report: EPP

Test Report: EPP Test Report: E 150 24 150W Single Output with FC Function DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Control Function Test Component Stress Test SAFETY & E.M.C.

More information

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns: 7-1 Section 7 Using the Illustrated List The parts lists provided in this section are organized into the following columns: Item Identifies illustrated parts that are available from Nordson Corporation.

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High

More information

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Tavor 8-T Active Ceiling Speaker P/N: 2900-300343 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions

More information

Product Guide LED OBSTRUCTION LIGHTS

Product Guide LED OBSTRUCTION LIGHTS Product Guide LED OBSTRUCTION LIGHTS Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO Aerodromes Design Manual, Chapter 18 Canadian

More information

Squirrel Cage 3-Phase Induction Motor TS21F-II SERIES

Squirrel Cage 3-Phase Induction Motor TS21F-II SERIES Squirrel Cage 3-Phase Induction Motor TS21F-II SERIES orizontal Foot Mounted 3-Phase / 50z, 60z / 3kV~11kV Frame Size N ~ N (IEC / METRIC) TEFC FIN CONSTRUCTION IEC STNDRD STNDRD SPECIFICTIONS Output Poles

More information

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W OCV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications

More information

Test Report: HB

Test Report: HB Test Report: HB-100-48 100W Single Switching ower Supply DESIGN VERIFY TEST Function Test Input Function Test rotection Function Test Other Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C.

More information