General Purpose High Power PCB Relays
|
|
- Kory Page
- 5 years ago
- Views:
Transcription
1 T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL 873 spacings - 8mm through air, 9.5mm over surface n Meets requirements of VDE 8mm spacing, kv dielectric coil-tocontact n Meets requirements of UL Class F construction n UL approved for 6VAC switching (.5HP) n New screw terminal version (consult factory for availability, ratings) Typical applications HVAC, residential / commercial appliances, industrial controls. Approvals UL E583 (Recognized and Listed); CSA LR87; VDE 96 Technical data of approved types on request. Contact Data Contact arrangement form A (NO), form C (CO) Rated voltage 77VAC Max. switching voltage 6VAC Rated current 3A NO; 3A NC Limiting continuous current A NO; 3A NC Limiting making current A NO; 3A NC Limiting breaking current A NO; 3A NC Contact material AgSnOInO, AgCdO Min. recommended contact load 5ma (NO)/ ma (NC), VAC Frequency of operation, with load 36hr Operate/release time max., including bounce 5/5ms Contact ratings ) Type Load Cycles UL58 AgCdO NO A, 77VAC, resistive 6x 3 NO 3A, /77VAC, resistive x 3 NO A, 6VAC, general purpose x 3 NO HP, VAC x 3 NO 3HP, VAC x 3 NO.5HP, 8 or 6VAC x 3 NO LRA/5.3FLA, VAC (DC coil only) x 3 NO 6LRA/FLA, VAC (AC coil only) x 3 NO 3A, VAC, pilot duty x 3 NO A, 8VDC, resistive x 3 NO TV, VAC x 3 NC 3A, 77VAC x 3 NC A, 8VAC x 3 NC A, 6VAC x 3 AgSnOInO NO 3A, /77VAC, resistive (DC coil only) x 3 NO 3A, /77VAC, resistive (AC coil only) x 3 NO A, 8VAC, resistive x 3 NO.5HP, VAC, pole making/breaking (Fig.) x 3 NO 3HP, VAC, 3 phase (DC coil only) x 3 NO 3HP, 8VAC, 3 phase (DC coil only) x 3 NO HP, 6VAC, 3 phase (DC coil only) x 3 VDE AgCdO, flange mount relays NO A, VAC x 3 NC 3A, VAC 3x 3 CO A NO / 3A NC, VAC 3x 3 AgCdO, PC mount relays NO 3A, VAC x 3 NC 3A, VAC 3x 3 CO 3A NO / 3A NC, VAC 3x 3 Contact ratings ) (continued) ARI Endurance Test (section 6.6): HVAC Definite Purpose Contactor Standard Normally Open Contacts Single Phase/Two Pole (Both poles together switching a single load) LRA, 5.3 FLA, K operations (DC Coil) L L Figure Single Phase Per Pole (Single load per pole) LRA, 8 FLA, K operations (DC Coil). 6 LRA, FLA, K operations (AC Coil). L L Figure T T ) Contact ratings at 5 C (unless otherwise noted) with relay properly vented. FLA, LRA ratings are compatible with 3.5 ton compressor applications. Mechanical endurance T T x 6 ops. Coil Data Coil voltage range 5 to VDC; to VAC Max. coil power.7w;.va Max. coil temperature 55 C Coil insulation system according UL Class F Coil versions, DC coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±% W Coil versions, AC coil Coil Rated Frequency Operate Release Coil Rated coil code voltage voltage voltage resistance power VAC Hz VAC, 6Hz VAC, 6Hz Ω±% VA / 5/ / 5/ /77 5/ All figures are given for coil without preenergization, at ambient temperature +3 C.
2 T9 Series Two-pole 3A PCB or Panel Mount Relay (Continued) Coil Data (continued) Ambient temperature vs. coil voltage Assumptions:. Thermal resistance = 35 C per Watt (DC only.). Still air. 3. Nominal coil resistance.. Max. mean coil temperature = 55 C (change of resistance method). 5. Coil temperature rise due to load = amps. 6. Curves are based on.7w at 5 C (DC only.). Max. Allowable Ambient Temp. ( C) AC Coil A AC Coil 3 A DC Coil Amp Contact Load DC Coil 3 Amp Contact Load Applied Coil Voltage (% of Rated Nominal) Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at /customersupport/rohssupportcenter Ambient temperature DC coil -55ºC to 85ºC AC coil -55ºC to 65ºC Category of environmental protection IEC 68 RTI - dust protected, RTII - flux proof, RTIII - wash tight Vibration resistance (functional).65mm max excursions, -55 Hz Shock resistance (functional) g for msec Shock resistance (destructive) g Terminal type PCB-tht or quick connect Weight 86g Resistance to soldering heat THT IEC C Packaging/unit tray/3 pcs., box/ pcs. Insulation Data Initial dielectric strength between open contacts between adjacent contact Initial surge withstand voltage Initial insulation resistance between insulated elements Clearance/creepage 5V rms V rms V rms 6kV x 9 Ω 8mm clearance/9.5mm creepage Dimensions T9 Mounting and termination code T9 Mounting and termination code, 3 and.6 MAX. (5.3).36 MAX. (3.5).7 MAX. (68.58).36 MAX. (3.5). MAX. (3.73).56 (3.96). MAX. (6.).95 MAX. (37.97).585 ±.5 (.86 ±.3).63 ±.5 (6. ±.3).68 ±. (. ±.5).39 ±.5 (7.85 ±.3).3 TYP. (.8). ±. (5. ±.5).7 TYP. (.9).5 TYP. (6.35).5 MAX. (5.7).35 ±.5 (59.56 ±.3).68 TYP. (. ±.5).585 ±.5 (.86 ±.3).39 ±.5 (7.85 ±.3).9 RAD. (.9) FOR #8 SCREW.63 TYP. (6.)
3 T9 Series Two-pole 3A PCB or Panel Mount Relay (Continued) Dimensions T9 Mounting and termination code 5.7 MAX. (68.58) Terminal assignment Bottom view on pins form A form C.35 ±.5 (59.56 ±.3).35 MAX. (5.3).36 MAX. (3.5).9 (.9) RAD. FOR #8 SCREW.3 MAX. (36.3) 6 8 PCB layout Bottom view on pins MAX. (3.9). MAX. (5.5) T9 - Mounting and termination code.39 (7.85).365 (9.7).585 (.86).68 (.).85 (.7).63 (6.). (5.).3 TYP. (5.6).5 TYP. (.3).6 (.).7 TYP. (.83) An alternate PC board layout utilizes.76 ±.3 (.93 ±.76) diameter holes on the same center-to-center spacing shown above. Use of the rectangular holes is recommended for improved solderability. Only necessary terminals are present on single throw models. Consequently, some holes will be unnecessary for single throw models. Product code structure Typical product code T9 S D - Type T9 Printed circuit board / panel mount power relay T9 Enclosure P Dust protected plastic case S Wash-tight, tape sealed, plastic case (Mounting and termination code ) Top sealed, not wash-tight, not tape sealed on bottom (Mounting and termination codes, 3 & ) Contact arrangement 7 form A ( NO) form C ( CO) Coil Input A AC voltage, 6Hz or 5/6 Hz (consult coil versions table) D DC voltage Mounting and termination Printed circuit board mount; printed circuit board terminals. Panel mount via flanged cover;.5 (6.35mm) x.3 (.8mm) QC terminal 3 Panel mount via flanged cover;.87 (.75mm) x.3 (.8mm) QC terminals for coil and.5 (6.35mm) for contacts Panel mount via flanged cover,.87 (.75mm) x. (.5mm) QC terminals for coil and.5 (6.35mm) for contacts. 5 Panel mount via flanged cover, M screws w/ captive pressure plates. Requires Enclosure P and Contact arrangement 7. Contact material AgCdO AgSnOInO Coil voltage Coil code: please refer to coil versions table 3
4 T9 Series Two-pole 3A PCB or Panel Mount Relay (Continued) Product Code Enclosure Contacts Coil Mounting Contact Material Coil Part Number T9P7A- Plastic dust cover form A, NO AC Panel mount + quick connect AgCdO VAC T9P7A- VAC T9P7A- VAC T9P7A VAC T9P7A- AgSnOInO VAC T9P7A5- Panel mount + screw terminals AgCdO VAC 38-8 T9P7A5- VAC -38- T9P7D- DC PCB terminals VDC T9P7D- VDC T9P7D- Panel mount + quick connect VDC T9P7D- VDC T9P7D-8 8 VDC T9P7D- AgSnOInO VDC -38- T9P7D- VDC 38-9 T9P7D- AgCdO T9P7D5- Panel mount + screw terminals VDC -38- T9P7D5- VDC T9PA- form C, CO AC PCB terminals VAC T9PA- Panel mount + quick connect VAC T9PA- VAC T9PA- VAC T9PA- VAC T9PA VAC T9PA- AgSnOInO VAC T9PA- AgCdO VAC T9PD- DC PCB terminals VDC T9PD- Panel mount + quick connect T9PD- VDC T9PD- AgSnOInO VDC T9PD- VDC T9S7A- Wash tight form A, NO AC PCB terminals AgCdO VAC T9S7A- VAC T9S7A- VAC T9S7A- Top sealed Panel mount + quick connect VAC 393- T9S7A- VAC 393- T9S7A- VAC T9S7D- Wash tight DC PCB terminals VDC T9S7D- VDC T9S7D-8 8 VDC T9S7D- VDC T9S7D- AgSnOInO VDC T9S7D- Top sealed Panel mount + quick connect AgCdO VDC T9S7D-8 8 VDC T9S7D- VDC T9S7D- VDC T9SA- Wash tight form C, CO AC PCB terminals VAC T9SA- VAC T9SA- VAC T9SA- Top sealed Panel mount + quick connect VAC T9SA- VAC T9SA- VAC T9SA- VAC T9SD- Wash tight DC PCB terminals VDC T9SD- VDC T9SD-8 8 VDC T9SD- VDC T9SD- Top sealed Panel mount + quick connect VDC T9SD- VDC
5 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: T9S7A-
PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)
PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and
More informationMounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B
A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles
More information10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC
Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external
More informationModel Number Structure
Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via
More informationPower Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops
Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated
More informationType Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder
A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with
More informationGeneral-purpose Relay
General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals
More informationPlug-in/solder terminals with LED indicator
General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole
More informationSupplementary protector S 200 MR for ring-tongue applications acc. to UL 1077
Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC
More informationDefinite Purpose Contactors 1, 2 and 3 pole Type GDP
Definite Purpose Contactors 1, 2 and 3 pole Type l Definite Purpose Contactors l Switching up to 100A resistive, 90A inductive l Line Voltage up to 600VAC on most sizes l Control voltage up to 480VAC l
More informationDJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing
Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated 02.17312.21
More information630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.
SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and
More informationUniversal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W
isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP
More informationSystem pro M compact Miniature Circuit Breaker S 200 U and S 200 UP
Data Sheet System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP 2CDC021316F0004 2CDC021320F0004 The S 200 U and S 200 UP ranges are miniature circuit breakers conforming to UL, CS and IEC
More information6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description
.1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................
More informationNH MULTIBLOC fuse-switchdisconnector. terminal version reference no.
NH fuse-switch-disconnector NH fuse-switchdisconnector ~ 690V screw fixing of disconnectors onto plates size rated current in A no. of poles terminal version art. group 00 160 1 screw M8 both sides F229292
More informationSIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationLimit Switches. 6.2 E47 Precision Switches
Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description............................................. 2 Approvals..................................................... 2 Features and Benefits...........................................
More informationElectronic Temperature Controls
ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple
More informationAmbient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage
SSR Power Controller SSR 1 SSR 2 SSR 3 Phase Single 2 Leg Switching 3 Phase DIN Rail/Panel Mounting Both Both Both Cooling Fan Optional Optional Optional Control MethodZero Cross Trigger / high isolation
More informationDistinctive Characteristics
Distinctive Characteristics Base of heat resistant resin meets ULV-0 flammability rating. Maximized voltage capability of V allows use in medium source applications and increases operating life. Award-winning
More informationPower Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -
SVL Essential DIN Rail Series SVL Series power supplies are perfect for high volume, controlled environment applications where essential features are the only requirement. When space inside an enclosure
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 480W Single Output Industrial DIN RAIL with FC Function SECIFICATION MODEL
More informationModel Number Structure
The reliable choice for Hockey-puck-style Solid State Relays. Available in a wide Range of Currents and Voltage. (5 to 90A, max 660 VAC) All models feature the same compact dimensions to provide a uniform
More informationMX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)
MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system
More informationDEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I
MIL-DTL-38999 Series I connectors are subminiature, environmental-class connectors with high and mediumdensity insert arrangements. They are used where a quickdisconnect coupling system is required for
More informationProduct Guide LED OBSTRUCTION LIGHTS
Product Guide LED OBSTRUCTION LIGHTS Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO Aerodromes Design Manual, Chapter 18 Canadian
More informationSmallest Connector with Removable Contacts
1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative
More informationL-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights
L-864 L-865 / L-864 L-810 L-810 Vigilant Series LED Based Obstruction Lights Certified to: FAA AC NO: 150/5345-43F FAA Engineering Brief No. 67 Compliant to: ICAO Annex 14, 4th Edition, July 2004 ICAO
More informationTest Report: HEP
Test Report: HEP-600-24 600W Single Output Switching Power Supply DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Control Function Test Component Stress Test SAFETY
More informationData Sheet for Precision Potentiometer
AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn
More informationDual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series
Dual Modular Safety Shutoff Valves with Proof of Closure Option DMV eco Series DMV-D eco Series DMV-DLE eco Series Two normally closed safety shutoff valves in one housing; each with the following approvals.
More informationData Sheet for Precision Potentiometer
The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19
More informationType CGS High-Cap Screw Terminal Aluminum Electrolytic Capacitor
High CV, Screw Terminal Capacitors Specifications Capacitance Range: Voltage Range: Capacitance Tolerance: Operating Temperature: Ripple Current Multipliers: Type CGS screw terminal, aluminum electrolytic
More informationAmphenol RF Interconnects TNC 31 Series Threaded Lock RF Connector System Materials
TNC 31 Series Threaded Lock RF Connector System Materials Body/Finish Contacts Centre MALE Centre FEMALE Insulator Gasket Crimp Ferrules* *Metal finishes Durability Brass/Nickel Brass/Gold Plated (Au)
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands
More informationReferences. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_156_a_2_cat Direct
More informationProduct Specification
HDBNC-BH1 Jack, Right Angle Orientation, PCB Terminated HDBNC-CA Plug, Straight Orientation, Cable Terminated Other configurations available for: Vertical cable-to-board applications Through-hole, edge
More informationHEATER POWER CONTROLLER
HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL
More informationAISI 316L PERFORMANCE RANGE INSTALLATION AND USE
CP-ST Stainless steel centrifugal pumps CP-ST4 Pump body: stainless steel AISI 304 Impeller: stainless steel AISI 304 Shaft: stainless steel AISI 431 CP-ST6 Pump body: stainless steel AISI 316L Impeller:
More informationEngineering Design Assurance Test Report ( S )
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationFLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing
FLFE..L FLF..L - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time Ex e terminal board housing Simplified maintenance 4 Joule shock resistant borosilicate glass White painted
More informationTest Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST
Test Report 240W Single Switching ower Supply DESIGN VERIFY TEST Function Test Input Function Test rotection Function Test Other Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test
More informationFIBER OPTIC CLOSURES
FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC
More informationElectrical Specifications. Dimensions (inches)
Page 7203 Electrical Specifications Valve Position Control 0.1 angular degree resolution Flow Control ± 1% of flow reading over a turndown of 20: 1 ir/fuel Ratio Control ± 2% with turndown of 20: 1 Power
More informationElectrical Specifications. Dimensions (inches)
Page 7203 Electrical Specifications Valve Position Control 0.1 angular degree resolution Flow Control ± 1% of flow reading over a turndown of 20: 1 ir/fuel Ratio Control ± 2% with turndown of 20: 1 Power
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 60W Single Output Industrial DIN Rail ower Supply DR-60 s e ries SECIFICATION
More informationEmergency Stop Devices
New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com
More informationB-Series Switches Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage treatment
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:
TEST EQUIPMENT LIST: INPUT FUNCTION TEST AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:
TEST EQUIPMENT LIST: INPUT FUNCTION TEST AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy
More informationEngineering Design Assurance Test Report ( S )
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationWork area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page
Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area:
More informationJameco SKU Number:
Jameco SKU Number: 2105560 SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER LINE REGULATION LOAD REGULATION HOLD U
More informationCH2 12V CH3-5V. 72W with 18CFM min. Forced air convection
Jameco SKU Number: 2457 65W Triple Output Medical Type M T-65 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY EMC (Note 4) OTHERS NOTE OUTUT NUMBER DC VOLTAGE RATED CURRENT CURRENT
More informationHeating and Cooling Components. Application Selection and Cross-Reference Guide
Heating and Cooling Components Application Selection and Cross-Reference Guide CONTACTORS Heat Sequencers REAYS TRANSFORMERS The Universal Choice Honeywell offers a complete range of relays, contactors
More informationULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES
ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES UPS MIL-SPEC COMPLIANT 1-5 KVA 1-5 U UNIVERSAL 120/240 VAC PFC INPUT SNMP COMMUNICATIONS WHEN EVERY POUND COUNTS! APPLICATIONS Shelters Tactical Systems Shipboard
More informationTest Report: HB
Test Report: HB-100-48 100W Single Switching ower Supply DESIGN VERIFY TEST Function Test Input Function Test rotection Function Test Other Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C.
More informationEmergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction
Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.
More informationTotal solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL
Total solder points: 129 Difficulty level: beginner 1 2 3 4 5 advanced LIQUID LEVEL CONTROLLER K2639 Forgotten to turn off the tap, leaking washing machines,... Prevention is better than cure. So use this
More informationElectric Smoke Damper Actuators
Bulletin Issue Date May 20, 2004 Electric Smoke Damper Actuators The Modulating Electric Smoke Damper Actuators are oil immersed, spring return, linkage coupled actuator for modulating damper control designed
More informationLOCAL DISCONNECT SWITCHES Manual Motor Controllers
LOCAL DISCONNECT SWITCHES Manual Motor Controllers 1 2 Ensto Manufacturer of electrical components and systems This brochure presents the economical, versatile and reliable Ensto Origin manual motor controllers
More informationEclipse Hermetic Gas Boosters Series HB
Datasheet 620 7/6/2012 Eclipse Hermetic Gas Boosters Series HB Version 1.1 Type Designations The booster is identified by catalog model, assembly number, and ordering part number. The catalog model number
More informationEC BRUSHLESS MOTOR APPLICATIONS
APPLICATIONS Due to their high efficiency are often used into applications that requires low power consumption combined to high performance. Many versions are available to meet various application requirements:
More informationDuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications
for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Wallpack_Bulkhead_Specsheet_Industrial_Jan2018
More informationDialight LED High Bay - High Output. Technical Specification Sheet - Americas
Dialight LED High Bay - High Output Technical Specification Sheet - Americas NOVEMBER 2018 High Bay - High Output High Bay Standard Corded Models Vigilant LED High Bay - High Output Standard Models Certifications
More informationPGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI
PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore
More informationSafety Interlock Switches
r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables
More informationTable of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved.
Illumination LUXEON Rebel PLUS The original high power LED LUXEON Rebel PLUS is designed with the highest possible efficacy and light output from an industry standard 4530 package with a 2.5mm 2 dome.
More informationYEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W
CV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High
More informationFeature. Model comment JG 3NA B L - B - D3
Feature Device type universal nut terminals with safety protective cover -A Power Output Rated load voltage 20VAC/VAC Triac power switch Have DC-AC (DC signal to control the AC load) AC-AC (AC signal to
More information320W Single Output with PFC Function
Jameco SKU Number: 2102730 320W Single Output with FC Function S-320 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE
More information60W Single Output Switching Power Supply
60W Single Output Switching ower Supply LC-60 series SECIFICATION MODEL LC-60-1050 LC-60-1400 LC-60-1750 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RANGE RATED OWER LINE REGULATION
More informationInstallation and Maintenance Manual
Freestanding Gas Stove MODEL: PGS2005 GPEBB20R GPEBW20R Installation and Maintenance Manual Warning Maintenance products should be carried out by professional and technical personnel with relevant qualification,
More informationTest Report: EDR-75-12
Test Report: EDR-75-12 75W Single Output Industrial DIN RAIL DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C.
More informationCEELOK FAS-T CONNECTORS
CEELOK FAS-T CONNECTORS Small Form Factor, Field Terminable Connectors CeeLok FAS-T connectors ofer a small form factor, ield terminable I/O connector capable of 0 Gb/s Ethernet. Crimpsnap contacts enable
More informationXENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL
TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger
More informationGeneral-Use Auto-Tuning HPX-T Series
General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display
More informationEPM Series Reversing Electric Actuators
EPM Series Reversing Electric Actuators Innovative Quarter-Turn Actuators that Look the Same on the Outside with the Hayward Difference on the INSIDE! Overview On/Off and Proportional Control Models Designed
More informationDuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications
DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 Features & Benefits 10 year warranty L70 rated for >100,000
More informationAVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators
AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators Avionics mounts are compact, lightweight vibration isolators that provide excellent vibration protection in all axes. Specially designed for the
More information50W Single Output Switching Power Supply
Jameco SKU Number: 540 50W Single Output Switching ower Supply LS-50 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 5) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT
More information60W Single Output Switching Power Supply
60W Single Output Switching ower Supply LV-60 series SECIFICATION MODEL LV-60-5 LV-60-12 LV-60-15 LV-60-24 LV-60-36 LV-60-48 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RATED CURRENT
More informationa Nexans company Catalogue 2009
a Nexans company Catalogue 2009 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationNK Multi-stage submersible pumps
NK Multi-stage submersible pumps PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 10 m APPLICATION LIMITS Maximum liquid temperature +40 C Maximum sand content 0 g/m³ 20 m maximum immersion
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. geprufre Sicherheit 60W AC-DC Single Output Desktop G S60 s e ries SECIFICATION
More informationAXICOM COMPOSITE HOLLOW CORE INSULATORS STANDARD TYPES
AXICOM COMPOSITE HOLLOW CORE INSULATORS STANDARD TYPES Normal sheds 2 AXICOM composite hollow core Table of contents Table of contents Presentation 3 I Normal sheds How to design your own AXICOM Insulator?
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CXM ELITE SERIES R-0A Ready - Multi-Position ulletin No. 0 March 0 Supersedes February 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMER IDENTIFICATION
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 120W Single Output Industrial DIN RAIL ower Supply DRH-120 s e ries SECIFICATION
More informationSafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1 MDTEXSSFLX001_B
SafeSite LED Floodlight - ATEX / IECEx for Outdoor Industrial Applications 1 www.dialight.com MDTEXSSFLX001_B On when it matters most. Products and solutions that protect your business 2 www.dialight.com
More informationLUXEON Rebel PLUS Freedom From Binning
LUXEON Rebel PLUS Freedom From Binning Hot Tested Superior Quality of Light Technical Datasheet DS107 LUXEON Rebel PLUS Freedom From Binning Introduction LUXEON Rebel PLUS LEDs from Philips Lumileds are
More informationDuroSite LED Floodlight - CE. for Outdoor Industrial Applications #
DuroSite LED Floodlight - CE for Outdoor Industrial Applications # On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Floodlight_SpecSheet_CE_100-277_VAC
More informationTest Report: APC
Test Report: AC-25-500 25W Single Output Switching ower Supply DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test
More informationTest Report: EPP
Test Report: E 150 24 150W Single Output with FC Function DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Control Function Test Component Stress Test SAFETY & E.M.C.
More informationSafeSite. Series LED Based Signaling for Hazardous Locations
SafeSite Series LED Based Signaling for Hazardous Locations Index 02 SafeSite L-864 Red LED Beacon 03 SafeSite LED Based L-864/L-865 Flashing Dual (White/Red) Strobe 04 SafeSite L-810 Red LED Obstruction
More informationB-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic
B-Series Switches Pressure, Differential Pressure, FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills
More informationPilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)
(general purpose valve) ADK11/ADK12 Series NC (normally closed) type, NO (normally open) type Port size: Rc1/4 to Rc1 Diaphragm structure Excluding ADK12 JIS symbol ADK11: NC (normally closed) type OUT
More informationSPEDESTER Series QUICK REFERENCE GUIDE
Spedester series Digital DC Drives come with an extensive range of standard software blocks, it can take control of the most demanding motion control tasks. Designed for industrial applications, Spedester
More information