General-Use Auto-Tuning HPX-T Series
|
|
- Stella Manning
- 5 years ago
- Views:
Transcription
1 General-Use Auto-Tuning HPX-T Series Built-in Hyper-tuning automatically adjusts scanning characteristics. Adjustment steps, results and scanning conditions are digitally displayed by LED. Digital display indicates adjustment steps, results and scanning conditions. Indication includes incoming light level, light level margin, insufficient sensitivity, maximum sensitivity setting. types of sensitivity setting can be selected: regular sensitivity setting (presence detection, back/front judgment), positioning sensitivity setting, maximum sensitivity setting. Remote-tuning types (T). Mutual interference prevention by pulse-phase shift system. AMPLIFIER UNIT ORDER GUIDE Output mode Operation mode Remote tuning NPN open collector PNP open collector Light ON/dark ON selectable HPX-T1 HPX-T NPN open collector HPX-T AMPLIFIER UNIT SPECIFICATIONS HPX-T1/T HPX-T Supply voltage to 0Vdc (ripple % max.) Current consumption 0mA max. Operation mode Light-ON/dark-ON, switch selectable Output mode Transistor open collector Control output Output switching circuit: 0mA max. (resistive load). Output dielectric strength: 0V max. Voltage drop: 1V max. (at 0mA switching current). Output short-circuit protection circuit. Response time 00µs max. for operation and recovery Sensitivity adjustment Sensitivity and hysteresis automatically set by button (auto-tuning) (Remote-tuning is possible on -T type by connecting the pink leads. * ) Light emitter Red LED (680nm) Display functions Digital display: incoming light level (in RUN mode), scanning margin/setting error (after sensitivity is set). Operation indicator: red (lit when output ON). Stability indicator: green (ON during stable L.O./ON during stable D.O.). OFF delay timer function: ON/OFF indication. Timer function OFF delay of 40ms or instantaneous, switch selectable Ambient light immunity Incandescent lamp:,000 lux max. Sunlight:,000 lux max. Operating temperature to + C (if gang mounted, to +0 C) Storage temperature 40 to +70 C Humidity range to 8% RH (condensation not allowed) Insulation resistance MΩmin. (at 00Vdc) Dielectric strength 00Vac, 0/60Hz for 1 minute between case and electrically live metal Vibration resistance to Hz, 1.mm peak-to-peak amplitude, times each in X, Y and Z directions Wiring type Preleaded Weight Approx. g (body only with cable) Other Reverse connection protection circuit, power ON/OFF malfunction prevention circuit (approx. 0ms) * Sensitivity setting only 1
2 Group Appearance Scanning distance (mm) Features Bend radius HPF-T001 Long distance Core: 1.4 dia. (1) Long scanning distance R HPF-T00 Core: 1.4 dia. (1) dia. HPF-T00 Sleeve 1. dia. FIBER UNIT Thru scan R HPF-T004 dia. Sleeve 1. dia. 6 ± 4 Sleeve (flexible) R/R HPF-T00 6 ± 4 HPF-T006 dia M diameter and compact R HPF-T04 Core: 0. dia. (1) M flexible, and small diameter R1 HPF-T04 Ultra bend - tolerant ± 0. 8 flexible, and standard model R HPF-T0 HPF-T01 dia. ± Sleeve 1 dia. 1. dia. flexible, and side view model R1 HPF-T06 Elbow R HPF-T0 Space saving Core: 0. dia. (1) flexible, small diameter, and flat top view model R1 HPF-T08 Front view 1.7 light axis center -M Side view. flexible, standard, and flat side view model R HPF-T08LF ± Sleeve 1 dia. 1. dia. R HPF-T007 Side view 1m R HPF-T07 Sleeve 0.88 dia.. dia. diameter R HPF-T04 dia. Small diameter Sleeve 0. dia. Core: 0. dia. (1) ± dia. R HPF-T0
3 Group Appearance Scanning distance (mm) Features Bend radius 6 HPF-T08 Core: 0. dia. (1) Sleeve 0.4 dia. 1.0 dia. 0.m HPF-T09 Core: 0.1 dia. (1) Small diameter Sleeve 0.4 dia. 60 ± R HPF-T040 Core: 0. dia. (1) dia. HPF-T04 Core: 0. dia. (1) dia. and long scanning distance HPF-T044 Core: 0.7 dia. (1) M HPF-T008 Core: 0. dia. (1) M Elastic small diameter HPF-T009 Elastic Core: 0. dia. (4) 1. dia. HPF-T046 Core: 0. dia. (4) 1. dia. Elastic standard diameter HPF-T0 Core: 0. dia. (16) To C R HPF-T01 Heat resistant Core: 1. dia. (1) Glass fiber: 1 dia. (0.0 dia. x ) (1) 1 17 To 0 C To 0 C 1m R R HPF-T017 HPF-T018 Glass fiber: 0.0 dia. (0.0 dia. x 70) 17 0 Heat and cold resistant from -60 C to +0 C R HPF-T014 ( incorporated) 17 Parallel beam top view HPF-T019 R Narrow beam ( incorporated) Parallel beam side view HPF-T0 4 dia. ( incorporated) 17 Narrow beam top view R HPF-T0 Mapping Core: 1. dia. (1) 9 ( incorporated) Narrow beam -1. /+1. max. side view R HPF-T00
4 Group Appearance Scanning distance (mm) Features Bend radius Array HPF-T01 Beam mm wide HPF-T01T Wide beam Beam mm wide Side beam R HPF-T01S Beam 0mm wide HPF-T01WT 4
5 Group Appearance Scanning distance (mm) Features Bend radius Long distance 0 Diffuse scan Long scanning distance R HPF-D001 Core: 1.4 dia. () HPF-D00. dia. 6 ± 4 1 R HPF-D00 7 R1 HPF-D09 M 60 R HPF-D00 Ultra bend - tolerant Sleeve 1. dia. 40 ± 7 (bendable) R/R1 HPF-D01 18 Core: 0. dia. (emitter core dia.)(1) Core: 0. dia. (receiver core dia.)(4) M 1 Coaxial R1/ HPF-D diameter R HPF-D044 dia. Compact 1. light axis center Core: 1 dia. () -M. For details, contact Yamatake Corporation. flexible, standard, and flat side-view model R HPF-D04LF HPF-D004 M 0 HPF-D00 Small diameter Sleeve 1. dia. 6 ± 4 Core: 0.7 dia. () Sleeve 0.8 dia. ± Core: 0. dia. () Sleeve 1. dia. ± Sleeve 0.8 dia. ± Core: 0. dia. () dia. dia. dia.. dia. long scanning distance 0.m 0.m R HPF-D006 HPF-D018 HPF-D019 HPF-D01 HPF-D09 Coaxial Core: 1 dia. (emitter core dia.)(1) Core: 0. dia. (receiver core dia.)(16) 1 Coaxial R HPF-D Core: 0. dia. (emitter core dia.)(1) Core: 0. dia. (receiver core dia.)(4) M R HPF-D0
6 Group Appearance Scanning distance (mm) Features Bend radius Coaxial 18 Core: 0. dia. (emitter core dia.)(1) Core: 0. dia. (receiver core dia.)(6) 18 Core: 0. dia. (emitter core dia.)(1) Core: 0. dia. (receiver core dia.)(9) 16 Core: 0. dia. (emitter core dia.)(1) Core: 0. dia. (receiver core dia.)(9) M M 18 Coaxial 0.m R HPF-D04 HPF-D0 HPF-D08 Side view Sleeve dia. Core: 0. dia. (emitter core dia.)(1) Core: 0. dia. (receiver core dia.)(9) dia. Sleeve dia. 40 ± 4 Sleeve dia. dia..8 dia. 1 coaxial short R HPF-D04 HPF-D0 HPF-D diameter R HPF-D04 6 dia. Core: 0. dia. (emitter core dia.)(16) Core: 0. dia. (receiver core dia.)(16) 70 HPF-D01 Elastic 6 Core: 0. dia. (emitter core dia.)() Core: 0. dia. (receiver core dia.)() 1. dia. 6 1m HPF-D06 Core: 0. dia. (emitter core dia.)() Core: 0. dia. (receiver core dia.)() M HPF-D07 70 To C R HPF-D To 0 C R HPF-D0 Core: 1. dia. () Heat resistant 14 To 0 C HPF-D0 Glass fiber: 1.4 dia. Sleeve.1 dia. 70 Glass fiber: 1.4 dia Sleeve heat resistant to 0 C 1m R HPF-D04 17 Glass fiber: 1. dia. 60 Heat and cold resistant from -60 C to 0 C R HPF-D0 (Built-in lens) Parallel beam (.7). Parallel beam reflection R HPF-D0 M Wide beam 1 7 Array HPF-D06 Limited reflection 1 (4.) ± 0. Limited reflection R HPF-D08 6
7 Wet process Group Appearance Scanning distance (mm) Features (Built-in lens) Bend radius Oil and chemicalproof 1.7 Core: dia. (effective lens dia.)(1) 4.7 dia dia. PFA tube small diameter R HPF-T09 HPF-T0 16 PFA tube R/R80 HPF-D014 6 dia. Liquid level 8 8 Pipe-mounted. Light received when liquid present. to 1mm dia. pipes. Pipe-mounted. Light received when liquid absent. 8 to 19mm dia. pipes. m HPF-T0 HPF-T04 (60)(Bending not allowed) Contact type. PFA tube 6mm dia. R/0 HPF-D07 6 dia. (40)(Bending not allowed) Contact type. PFA tube 4mm dia. R/R0 HPF-D0 4 dia Liquid leak 1 Contact type m R HPF-D040 4 Vacuum Group Appearance Scanning distance (mm) Features Bend radius Thru scan Diffuse scan Glass fiber: 1. bundle dia. (1) Glass fiber: 1.7 bundle dia. Glass fiber: 1.7 bundle dia. 0 Heat resistant to 0 C. Elbow connection Heat resistant to 0 C. Straight connection 1m R HPF-VT07 HPF-VD07 HPF-VD09 Core: 1 dia. Air side ( units) R HPF-VA (8) Heat resistant to 0 C. Light connector ( units) HPF-VJ0 1 7
8 SCANNING DISTANCE WITH LENS ATTACHMENTS Attachment Fiber unit Scanning distance (standard target object) Micro-spot lens HPF-LU01 HPF-D0 Long-distance micro-spot lens HPF-LU0 HPF-D0 Long-distance lens FE-PA-L1 HPF-T00 HPF-T004 HPF-T0 HPF-T01 HPF-T014 HPF-T018 7mm 19mm 1,740mm 1,740mm 1,60mm 680mm 960mm 900mm Attachment Side-view unit FE-PA-S1 Fiber unit HPF-T00 HPF-T004 HPF-T0 HPF-T01 HPF-T014 HPF-T018 Scanning distance (standard target object) 90mm 90mm 170mm 140mm 1mm 1mm EXTERNAL DIMENSIONS (unit: mm) Amplifier unit 1.8 When mounted on bracket (supplied) 4 OFF delay timer indicator. Incoming light indicator (lights red) Tuning button.9 L-ON/D-ON selector switch Stability indicator (lights green) Mode selector switch Digital indicator Fiber clamp lever Released Locked 1. Cover dia (.4) dia. Hole. 16 Optical fiber unit 1.4. Mounting bracket NAMES OF PARTS Digital indicator Incoming light level display (in RUN mode) Scanning margin display (after tuning) Defective setting (error) display OFF delay timer indicator Lights red when OFF delay timer is ON. Auto-tuning button OFF delay timer / regular operation selector switch Operation indicator Lights when output is ON. L-ON/D-ON selector switch Selects light-on /dark-on operation. Stability indicator Green during stable L.O. and D.O. operation Mode selector switch Selects RUN mode / SET mode. 1 8
9 OPERATIONAL TIMING CHARTS FOR OUTPUTS & INDICATORS HPX-T remote sensitivity setting Hysteresis level can be set by externally input auto-tuning signal instead of by pressing the tuning button. (Note that positioning and maximum sensitivity cannot be set.) 1 9
10 SCANNING MARGIN DISPLAY The following table shows the correspondence between the scanning margin and the digital display after the sensitivity has been set. Scanning margin display (digital indicator) Margin (factor) for 1.0X min. automatically set hysteresis 1.X min. 1.X min. X min. X min. 4X min. X min. 6X min. 7X min. OUTPUT CIRCUIT HPX-T1 (NPN) HPX-T (PNP) HPX-T (NPN)
11 WIRING DIAGRAMS HPX-T1 (NPN) When driving a direct load HPX-T (PNP) When driving a direct load HPX-T (NPN) When driving a direct load PRECAUTIONS FOR USE 1. Mounting method The single-touch DIN-mounting system allows the HPX-T to be mounted on a DIN rail without using any tools. DIN 1.1 rail mounting/dismounting To mount, hook the front of the amplifier over the DIN rail. When 1. a DIN rail is not used Rear lever DIN rail Push down the rear of the amplifier onto the DIN rail until it clicks into place. To remove the HPX-T from the DIN rail, pull out the rear lever with a flat-head screwdriver. When not using a DIN rail, use the mounting bracket (supplied). To mount the HPX-T on the mounting bracket, follow the same procedure as for the DIN rail.. Precautions for use Wiring.1 Be sure to connect the photoelectric sensor to the power supply and load correctly. If high-voltage or power lines are located near a photoelectric sensor, isolate the photoelectric sensor's cable or put it in a separate conduit to prevent surge or the influence of electrical noise. Connect the cable securely using crimp terminals or the like. If extending the cable, use wire of at least 0.mm in cross-sectional area. The lead length should be kept to 0m at most. When extending the cable, consider the possible influence of increased electrical noise. If a switching power supply is used, ground its frame. If a capacitive load is used, connect a current-limiting resistor to limit inrush current to 0mA or less. Handling. Do not swing a photoelectric sensor by its cable. Do not strike or scratch the scanning head. Do not pull the cable of the photoelectric sensor with excessive force. The pullout strength of the cable 0cm from where it exits the body is about 49N.
HPX Series. General-Use Potentiometer Tuning
General-Use Potentiometer Tuning HPX Series High Sensitivity over a Long Scanning Distance of 00mm (Thru Scan Model), Easy-to-Use Functions/Structure, and High Reliability. Quick response (µs) plus mark
More informationHPX-ET Series. Gang-Mounted Remote Cluster
Gang-Mounted Remote Cluster HPX-ET Series Connector connection type 16-unit gang-mounting sensors strongly support the request for wiring and space savings. Distributed remote cluster arrangement is a
More informationHPF Series. Fiber Units. Wide range of models for various applications and environments COMPATIBLE AMPLIFIERS HPX-AG HPX-ET HPX-T
Fiber Units HPF Series Wide range of models for various applications and environments COMPATIBLE AMPLIFIERS Type Catalog listing Appearance Digital fiber-optic sensors HPX-AG Gang-mounted distributed remote
More informationModel Number Structure
Solid State Relays Refer to Safety Precautions for All Solid State Relays. Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via
More informationMounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B
A High-capacity, High-dielectricstrength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated coil that handles
More information10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC
Solid State Relays G3NE Compact, Low-cost, SSR Switching 5to20 A Wide load voltage range: 75 to 264 VAC. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external
More informationPower Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops
Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated
More informationFiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia.
s Through-beam (Sold in Pairs) E2-TL (T = 2.) M2.6 x (for M) 1. dia. 0.5 (nickelplated brass) M x Optical fiber, 2.2 dia. 0. E2-T12L 1. dia. 2. dia. (nickel-plated brass) dia. Optical fiber, 2.2 dia..2
More information1,100 (2,600) *1 M4 screw
# / 9 / ± µ D DD Ω H H I µ 99 Ω I : High-resolution mode : Standard mode : Super-high-speed mode ; 1,0 (2,600) *1 M4 screw 870 (2,000) 350 (840) 1,0 870 3-mm dia. 350 340 M3 screw 260 0 2-mm dia. 0 340
More informationGeneral-purpose Relay
General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals
More informationType Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder
A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with
More informationPCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)
PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and
More informationPlug-in/solder terminals with LED indicator
General-purpose Relay LY Electromechanical Relays A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole
More informationAmbient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage
SSR Power Controller SSR 1 SSR 2 SSR 3 Phase Single 2 Leg Switching 3 Phase DIN Rail/Panel Mounting Both Both Both Cooling Fan Optional Optional Optional Control MethodZero Cross Trigger / high isolation
More informationTRUMPF TRUMATIC L 3050
TRUMPF TRUMATIC L 3050 CNC laser cutting machine Manufacturer TRUMPF Model TRUMATIC L 3050 Year of manufacture 2004 Control Machine number Travels SIEMENS SINUMERIK 840 D A0230A0580 X 3.000 mm / Y 1.500
More informationUniversal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W
isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP
More informationData Sheet for Precision Potentiometer
AL(R)17/19 soldering lugs The AL(R)17/19 potentiometers in 22 mm housing are suitable for applications where a precise and economical multiturn potentiometer is important. Economical and precise multiturn
More informationElectronic Temperature Controls
ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple
More information6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description
.1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................
More informationData Sheet for Precision Potentiometer
The ALI(R)17/19 potentiometers in mm housing are suitable for applications where a precise multiturn potentiometer increased radial shaft loads is important. ALI(R)17/19 reinforced bearing ALI(R)17/19
More informationChoose the performance you need
Choose the performance you need General application STEP 1: The fiber optic sensor heads Standard cylindrical Square shape Long distance Enhanced environment resistance Chemical resistant Heat resistant
More informationEngineering Design Assurance Test Report ( S )
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationEmergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction
Emergency Stop Switch Install in 22-dia. or 25-dia. Panel Cutout Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1,. Safety Lock Mechanism prevents misuse.
More informationIB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display
IB 7/40 Classic Thanks to airflow optimisations, our Ice Blaster IB 7/40 impresses with excellent results during dry ice cleaning, even when working with low air pressures. Compact device. 1 Automatic
More informationTest Report: HEP
Test Report: HEP-600-24 600W Single Output Switching Power Supply DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Control Function Test Component Stress Test SAFETY
More informationEngineering Design Assurance Test Report ( S )
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 480W Single Output Industrial DIN RAIL with FC Function SECIFICATION MODEL
More informationFeature. Model comment JG 3NA B L - B - D3
Feature Device type universal nut terminals with safety protective cover -A Power Output Rated load voltage 20VAC/VAC Triac power switch Have DC-AC (DC signal to control the AC load) AC-AC (AC signal to
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 60W Single Output Industrial DIN Rail ower Supply DR-60 s e ries SECIFICATION
More informationSPEDESTER Series QUICK REFERENCE GUIDE
Spedester series Digital DC Drives come with an extensive range of standard software blocks, it can take control of the most demanding motion control tasks. Designed for industrial applications, Spedester
More informationReferences. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_156_a_2_cat Direct
More informationFERRULES & TOOLS Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)
TerminalBlocks_072012(alt-2).QD_Blocks 10/23/12 9:05 AM Page 117 To help you do the best job possible when using Altech s terminal blocks, we put together a selection of useful tools to accomplish just
More informationSupplementary protector S 200 MR for ring-tongue applications acc. to UL 1077
Electrical installations in buildings for ring-tongue applications acc. to UL 1077 S 200 MR is a high-performance supplementary protector with ring cable lug connections conforming to UL, CSA, and IEC
More informationSafety Interlock Switches
r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables
More informationUSER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Tavor 8-T Active Ceiling Speaker P/N: 2900-300343 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax
TEST EQUIPMENT LIST: AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy wave surfer 424
More informationPlease read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.
OPERATING GUIDE for Secabo mini Cutting Plotter Congratulations on purchasing your Secabo mini cutting plotter! Please read this guide carefully. It tells you how to prepare your cutting plotter for production
More informationJameco SKU Number:
Jameco SKU Number: 2105560 SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER LINE REGULATION LOAD REGULATION HOLD U
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:
TEST EQUIPMENT LIST: INPUT FUNCTION TEST AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High
More informationEngineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:
TEST EQUIPMENT LIST: INPUT FUNCTION TEST AC Source : Chroma programmable AC source Model 61504 Power Analyzer : Chroma Power Analyzer Model 6630 Load : Chroma Electronic DC Load 63103 Oscilloscope : Lecroy
More informationLab Skills: Introduction to the Air Track
Lab Skills: Introduction to the Air Track 1 What is an air track? An air track is an experimental apparatus that allows the study of motion with minimal interference by frictional forces. It consist of
More informationTotal solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL
Total solder points: 129 Difficulty level: beginner 1 2 3 4 5 advanced LIQUID LEVEL CONTROLLER K2639 Forgotten to turn off the tap, leaking washing machines,... Prevention is better than cure. So use this
More informationNORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES
1 MANUFACTURER: MODEL: NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI 54115 UNITED STATES NORTHFIELD CLS SPECIFICATIONS: VOLTAGE: FREQUENCY: CURRENT: AIR: 115VAC-230VAC 50/60Hz 5 AMP 80 PSI (for
More informationMX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)
MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL4024 Safety Interlock Switch with uard Door Locking High locking force of 1,500 N (7 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure withstands
More informationCH2 12V CH3-5V. 72W with 18CFM min. Forced air convection
Jameco SKU Number: 2457 65W Triple Output Medical Type M T-65 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY EMC (Note 4) OTHERS NOTE OUTUT NUMBER DC VOLTAGE RATED CURRENT CURRENT
More information630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.
SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and
More informationSIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationAccessories. LED AWNING LIGHT RGB External LED light available in white or multi-colored (RGB).
RAFTER LED The classic central rafter for the fabric, equipped with 36 LED lights. AWNING ARMS LED Two pairs of LED strips for the arms of the awning. KIT AWNING LED Pair of LED to be fixed on the front
More informationIB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility
IB 15/120 The Ice Blaster IB 15/120 is one of the most powerful dry ice blasting machines on the market. It impresses with its robustness, highly reliable technology and the best results in dry ice cleaning.
More informationCapacity 24 bottles Six shelves cradle bottles horizontally to keep corks moist o Shelves are coated to reduce vibration
Standard Features & Accessories REFRIGERATION All models include Hidden touchpad electronic controls with digital temperature readout o Inside temperature can be adjusted from 40 65ºF o TruProtect system
More informationDUWC1441 Designer. cabinet, and black interior.
Standard Features & Accessories REFRIGERATION All models include: Hidden touchpad electronic controls with digital temperature readout o Inside temperature can be adjusted from 40 65ºF o TruProtect system
More informationTest Report: EDR-75-12
Test Report: EDR-75-12 75W Single Output Industrial DIN RAIL DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C.
More informationSystem pro M compact Miniature Circuit Breaker S 200 U and S 200 UP
Data Sheet System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP 2CDC021316F0004 2CDC021320F0004 The S 200 U and S 200 UP ranges are miniature circuit breakers conforming to UL, CS and IEC
More informationE32 Series. Fiber Units Support an Increasing Range of Applications. Fiber Units. Features. Standard Models First, Our Standard Lineup Page 18
Photoelectric Units Units Support an Increasing Range of s Standard Models Models available in a wide variety of shapes customization service for virtually any application Environment-resistive Models
More informationProduct information Truma VarioHeat and E-Kit. July 2018
Product information Truma VarioHeat and E-Kit July 018 Truma VarioHeat The new compact Truma heaters for motor homes, caravans and vans. Truma VarioHeat eco and Truma VarioHeat comfort are of an identical
More informationSR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features
Series AC Erie Boiler Boss Universal Control Relay General Instructions Application he AC Boiler Boss series zone control relay incorporates a double pole/double throw relay to control a circulator and
More informationInstallation and Maintenance Manual
Freestanding Gas Stove MODEL: PGS2005 GPEBB20R GPEBW20R Installation and Maintenance Manual Warning Maintenance products should be carried out by professional and technical personnel with relevant qualification,
More informationINSTRUCTION MANUAL ALEKO RETRACTABLE AWNING
INSTRUCTION MANUAL for ALEKO RETRACTABLE AWNING www.alekoproducts.com FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY! 1 Important Safety Precautions WARNING NOTE: FOR PERSONAL SAFETY,
More informationDJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing
Pushbuttons toggle switch 6,35 mm dia. toggle switch 6,35 mm dia. no. of poles material of contacts Switching position connection method colour part no. 2 silver 2 (maintained chromiumplated 02.17312.21
More informationREFRIGERATION. Standard Features & Accessories. Model Options. Undercounter/Freestanding 24 W. Dual Zone Wine Cellar
Standard Features & Accessories All models include: Hidden touchpad electronic controls with digital temperature readout o Inside temperature can be adjusted from 40 65ºF in each compartment o TruProtect
More informationInsulated Scissors. Handles made with shock-proof plastic. Length Blade Std. Part No. Type mm shape Pk.
Cutting Tools Cable Cutter - For copper and aluminum cables only. Extremely high cutting capacity with adjustable screw joint. for cable Length Std. Part No Type Ømm mm 2 AWG mm Pk. AP1017 N 15 50 1/0
More informationOptional accessories. markilux shadeplus. Optional accessories
markilux shadeplus for the markilux 1000/1000 stretch, 1100, 1300/1300 stretch, 1500, 1600/1600 stretch, 5010 and 6000 Create new living space in the open air by means of the markilux shadeplus / drop
More informationHEATER POWER CONTROLLER
HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL
More informationDIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions
Analogue Timer Model H3DS-M/-S/-A H3DS-F H3DS-G Features DIN Track Mounting, Standard mm Width, Solid-state Multifunctional Timer with Smart Dial/Selector-locking Mechanism DIN Track Mounting, Standard
More informationLimit Switches. 6.2 E47 Precision Switches
Limit Switches E47BMS02 E47BMS11 E47BMS40.2 Product Description............................................. 2 Approvals..................................................... 2 Features and Benefits...........................................
More informationElectric Smoke Damper Actuators
Bulletin Issue Date May 20, 2004 Electric Smoke Damper Actuators The Modulating Electric Smoke Damper Actuators are oil immersed, spring return, linkage coupled actuator for modulating damper control designed
More informationYEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W
CV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications
More informationFIBER OPTIC CLOSURES
FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics IN-LINE TYPE FIBER OPTIC
More informationXENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL
TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. E 06.02.14 Tranberg AS P.O. Box 8033 N-4068 Stavanger
More informationUSER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)
USER MANUAL BMU WORKCAGE CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999) All persons operating this equipment must read and completely understand this manual. Any operation in violation
More informationYEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W
OCV5 Slim 12V Outdoor Converter 5 YEARS IP67 50.000 hrs The perfect partner to team up with any 12V LED solution Full power range from 15W to 200W SLIM profile (40x23mm) to fit in very thin applications
More information12V DIRECT RESPONSE. Installation Manual
CAREFREE 2V DIRECT RESPSE Installation Manual AUTO-RETRACT SYSTEM The 2V Direct Response Auto-Retract System may be installed as part of the original motorized awning installation or as an upgrade to an
More informationREFRIGERATION. Standard Features & Accessories. Model Options. Undercounter/Freestanding 24 W. Wine Cellar
Standard Features & Accessories REFRIGERATION All models include: Hidden touchpad electronic controls with digital temperature readout o Inside temperature can be adjusted from 40 65ºF o TruProtect system
More informationTest Report: HB
Test Report: HB-100-48 100W Single Switching ower Supply DESIGN VERIFY TEST Function Test Input Function Test rotection Function Test Other Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C.
More informationC/L TIMER v4.x _
The active timer controls the ESC actuating in the motor RPM during flight based on the data received from the accelerometer, keeping the flight speed more constant and making it possible to have flights
More informationModel Number Structure
The reliable choice for Hockey-puck-style Solid State Relays. Available in a wide Range of Currents and Voltage. (5 to 90A, max 660 VAC) All models feature the same compact dimensions to provide a uniform
More informationFire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A
Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS For your safety: If you smell gas: 1. Shut off gas to the appliance 2. Extinguish
More informationPGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI
PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore
More informationJetCat USA 4250 Aerotech Center Way, Building G Paso Robles, CA 93446
Instruction manual 6V Kerosene Start System V2 (Part Number A1051-2) JetCat USA 4250 Aerotech Center Way, Building G Paso Robles, CA 93446 805-226-8700 Voice 805-226-8742 FAX www.jetcatusa.com 1 Content
More informationOREON GROW LIGHT 2.2
OREON GROW LIGHT 2.2 (GL 600 2.2 XXX) INSTALLATION MANUAL Version: 20180830US/CA IMPORTANT: READ CAREFULLY BEFORE STARTING INSTALLING THE FIXTURE. KEEP FOR FUTURE REFERENCE. MANUAL FOR INSTALLER Thank
More information20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
20W Single Outut Industrial DIN Rail Power Suly MODEL:MDR-20-12 OUTPUT FUNCTION TEST 1 RIPPLE & NOISE V1: 120 mv- (Max ) I/P: 230VAC V1: 19 mv- (Max ) 2 OUTPUT VOLTAGE CH1: 10.8 V~ 13.2 V 10.21 V~ 13.85
More informationModel. Oasis Automatic and Manual RV Door Awning System INSTALLATION & OPERATING INSTRUCTIONS
Oasis Automatic and Manual RV Door Awning System USA SERVICE OFFICE Dometic Corp. 509 So. Poplar St. LaGrange, IN 46761 260-463-4858 CANADA Dometic Dist. 866 Langs Dr. Cambridge, Ontario CANADA N3H 2N7
More informationBlue Series Hot Melt Hose with RediFlext II Hanger System
Instruction Sheet P/N 1124594_01 Blue Series Hot Melt Hose with RediFlext II Hanger System Safety WARNING! Allow only personnel with appropriate training and experience to operate or service the equipment.
More informationPrimrose Awnings - Full Cassette Manual & Electric Instructions
Primrose Awnings - Full Cassette Manual & Electric Instructions Contents Warning 2.0m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m - 5.0m Awnings 12 x Expansion bolts **
More information15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
15W Single Output Switching ower Supply MODEL:RS-15-15 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1:120 mvp-p (Max ) I/: 230VAC O/:FULL LOAD V1: 52 mvp-p
More informationGeneral Purpose High Power PCB Relays
T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL
More informationSmallest Connector with Removable Contacts
1 Ultra-Miniature 8STA Size 01 Connectors Smallest Connector with Removable Contacts Ultra compact design and very lightweight connector dedicated to the harshest of motorsport environments. Innovative
More information60W Single Output Switching Power Supply
60W Single Output Switching ower Supply LV-60 series SECIFICATION MODEL LV-60-5 LV-60-12 LV-60-15 LV-60-24 LV-60-36 LV-60-48 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RATED CURRENT
More information120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
120W Single Output Industrial DIN RAIL ower Supply MODEL:DRH-120-24 OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 80 mvp-p (Max ) I/: 400 VAC O/:FULL LOAD
More informationParts Catalog T7/T71/T73 M40000/M40001/M40003
T7/T71/T73 M40000/M40001/M40003 REPAIR PARTS CATALOG NO. M30202(R) For Machines with Serial No. T6183-T9031 ISSUED July 2009 ORDERS Please use Part Numbers when ordering and include the the machine Serial
More informationRMC1E - Variable Flame Height EASY Control
Owner s Manual RMC1E - Variable Flame Height EASY Control General Assembly, Installation, and Operation Instructions for use with Natural Gas Burners; F, FX, CS, CXF, TNA or Propane Gas Burners: FA, FAX,
More informationStrut Clamp Pipe & Conduit
PRODUCT SPECIFICATIONS 0F Strut Clamp Pipe & Conduit Size: Steel pipe sizes 2" through 0" Finish: Electro-Galvanized Pipe clamps are designed to fit into the opening of 5 /8" wide channel profiles Pre-Assembled
More informationUltramodern remote control technology for your patio comfort. Comfortable WeiTronic remote control.
Comfortable WeiTronic remote control Ultramodern remote control technology for your patio comfort The WeiTronic operating comfort allows you to control your weinor accessories with ease through practical
More informationAquastream. Thermo. Thermostatic integral power shower. Installation guide. Aquastream Thermo installation instructions Page 1
Aquastream Thermo Thermostatic integral power shower Installation guide Aquastream Thermo installation instructions Page 1 Aquastream Thermo Aquastream Thermo Thermostatic integral power shower Satin chrome
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. geprufre Sicherheit 60W AC-DC Single Output Desktop G S60 s e ries SECIFICATION
More informationDual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series
Dual Modular Safety Shutoff Valves with Proof of Closure Option DMV eco Series DMV-D eco Series DMV-DLE eco Series Two normally closed safety shutoff valves in one housing; each with the following approvals.
More information212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad
International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad Stand Alone Keypad-Installation Manual Features: 120 User Capability
More informationHardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay
HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay HardSID Uno / UPlay user s guide 2010 Hard Software, Hungary 1 Safety information... 4 Introduction:... 5 Package contents... 5 System requirements...
More information