1 ID Self Pack Packing Device for ImmunoDetection Cartridges Operating Instructions In This Document This document describes how to pack your own ImmunoDetection (ID ) Sensor Cartridges for use in Perfusion Immunoassays, automated assays that selectively capture biomolecules in a rapid, reproducible, flow-through format. You can immobilize the ligand before or after packing the sensor If you are immobilizing ligand before packing, refer to the Immobilizing Ligand for Perfusion Immunoassays document provided before continuing. Packing Device Parts The Self Pack packing device is made of corrosion-resistant 316L stainless steel that can be used with salt buffers. The packing device consists of these parts: Cap (center cover and lock nut) O-ring Chamber A backpressure regulator is included with the packing device. Figure 1 shows the parts of the packing device and the backpressure regulator. Related documents You receive two documents with the POROS Self Pack media: Outlet End Inlet End O-ring Cap Immobilizing Ligand for Perfusion Immunoassays Refer to this document before packing the cartridge, if you want to immobilize ligand on a batch of media. Refer to this document after packing if you want to immobilize on the packed Performing Unlabeled Perfusion Immunoassays Refer to this document after immobilizing ligand and packing the Backpressure regulator PB Chamber Lock nut Center cover 1 Product Description The ID Self Pack Packing Device for ImmunoDetection Sensor Cartridges lets you pack and repack empty PEEK 2.1 mmd/30 mml cartridges with POROS affinity Self Pack media. By packing your own ID cartridges, you get increased reproducibility between cartridges, flexibility in immobilization chemistry, and unsurpassed affordability. Figure 1 Packing Device Parts Flat surfaces on the packing device chamber allow you to grasp the chamber with a wrench if necessary, but hand tightening is usually sufficient. You purchase empty cartridges, ID Self Pack media, and reagents separately from the packing device. In These Instructions These instructions describe how to use the packing device and related hardware. They explain the following: How to assemble the packing device How to adapt the packing device to different LC instruments How to pack your own cartridges How to unpack a cartridge Section Page 1 Product Description Additional Items Needed to Pack Your Cartridge Preparing Your Equipment for Packing Packing a Cartridge Running the Packed Cartridge Unpacking a Cartridge Storing Packing Device and Cartridge Accessories, Spare Parts, and Ordering Information Technical Support

2 The inlet end of the chamber connects to your LC instrument. It includes the following: A screw-on 2-piece cap with a female fitting. You can adapt this fitting to M-6 metric systems (such as the Pharmacia FPLC system) or 1/4-28 systems by using the fitting adaptor kit supplied with the packing device. An O-ring seated in a depression around the rim of the inlet opening. The O-ring lets you hand-tighten the cap, even when you use the packing device with high-pressure instruments. The outlet end is the narrow end of the chamber, where: Two end plugs Two EZ Grip fittings and ferrules that are used to connect the packed cartridge to a system End fittings are assembled on the tube, and the end plugs and frits are installed. Figure 2 shows a PEEK cartridge without end plugs. End fitting You can connect an empty 2.1 mm diameter PEEK A white Teflon washer recessed in the outlet end of the packing chamber creates a proper seal when a cartridge is screwed in place. (This washer is not visible in Figure 1.) Tube Frit Fitting Adaptor Kit The fitting adaptor kit adapts the Self Pack packing device to M-6 metric or 1/4-28 LC systems. (For ordering information, see Table 2 on page 6.) The kit provides these fittings: 2 red Fingertight fittings 2 beige ferrules (barrel shaped) 2 black metric nuts 2 green nuts 2 blue ferrules (cone shaped) 2 pieces of orange inch I.D. PEEK tubing To use the fitting adaptor kit, do the following: 1. Connect one end of the orange tubing to an M-6 or 1/4-28 system. For M-6 systems: Slip a black nut over the tubing followed by a blue ferrule, with the conical end pointing toward the nut. Connect to the LC system and finger tighten. For 1/4-28 systems: Slip a green nut over the end of the tubing, followed by a blue ferrule, with the conical end pointing away from the nut. Connect to the LC system and finger tighten. 2. Put a red Fingertight fitting on the other end of the tubing, followed by a beige ferrule. The fitting is now ready to be connected to the fitting on the cap of the packing device. Because the cap is heavy, do not attach it now. Wait until you are ready to attach the cap to the chamber (see Section 4.2, Filling the Packing Device). 2 Additional Items Needed to Pack Your Cartridge In addition to the packing device, to pack a cartridge you need an empty PEEK cartridge, POROS Self Pack media (purchased separately), and your own ligand for immobilization. You can order this equipment from PerSeptive Biosystems. For ordering information, see Section 8, Accessories, Spare Parts, and Ordering Information. PEEK Cartridges Empty PEEK ID cartridges are sold in packages of 5, 10, or 20. Each empty PEEK cartridge comes with these parts: One hollow tube Two end fittings, which screw onto threads at either end of the cartridge tube Two frits that are placed in the end fittings to retain the media PB Figure 2 PEEK Cartridge Parts 3 Preparing Your Equipment for Packing To pack a cartridge, do the following: Clean the cartridge and packing device Prepare the slurry solvent and packing solvent Prepare the packing device Prepare your LC system Assemble the packing device and empty cartridge Position the packing device Lab Equipment Needed In addition to the packing device and empty cartridge, you need this equipment to pack a cartridge: LC system Spatula Glass beaker of 50 ml or greater Squirt bottle Laboratory tissue 25 ml graduated cylinder or 20 ml pipette Deionized water 3.1 Cleaning the Cartridge and Packing Device NOTE: Observe good laboratory practice. Wear safety glasses during the following procedures. The cartridge and packing device are reusable. You clean them differently depending on whether you have used them before. Never Used End plug If the cartridge and packing device have never been used, do the following: Cartridge: Unscrew the end fittings and flush the tube and end fittings with deionized water. Do not reassemble the Set all the pieces aside. Packing device: Wash or sonicate the packing chamber and cap with 50% isopropanol, ethanol, or other alcohol to ensure cleanliness. Set all the pieces aside. 2

3 Previously Used If the cartridge or packing device has been used before, clean it before each reuse to avoid contamination with packing material left over from a previous use. Cartridge: Sonicate the tube, end fittings, and frits in 50% isopropanol, ethanol, or other alcohol for 10 minutes. Rinse all pieces thoroughly with deionized water. Set all the pieces aside. Packing device: Flush the packing device cap with deionized water and thoroughly wash the threads at the outlet end of the chamber. Residual media gets trapped in the threads during normal use. Wash the O-ring. Flush with organic solvent if you see any media residue on surfaces after the water wash. Rinse again with water to remove the organic solvent. Do not reassemble the packing device. Set all the pieces aside. 3.2 Preparing the Slurry Solvent and Packing Solvent To prepare the slurry solvent and packing solvent, do the following: 1. Prepare your slurry solvent and packing solvent (Table 1). Table 1 2. Fill the squirt bottle with the slurry solvent. 3.3 Preparing the Packing Device Make sure the white Teflon washer is installed in the outlet end of the chamber. The washer is required for a proper seal to pack the 3.4 Preparing Your LC System To prepare your LC system, do the following: Prepare the tubing Set the pressure limit Prepare the pumps Preparing the Tubing Slurry Solvents and Packing Solvents for Self Pack Media POROS Self Pack Media Slurry Solvent Packing Solvent AD 100 % ethanol 5 % ethanol BA, EP, AL, XL, PG, PA Water Water Make sure that the fitting on the end of your LC system pump outlet tubing is compatible with the fitting on the packing device cap. If it is not, use the fitting adaptor kit. See Fitting Adaptor Kit on page 2. Do not connect the free end of the pump outlet tubing to the cap of the packing device yet. For example, on an FPLC system, do the following: 1. Connect one end of the orange tubing of the fitting adaptor kit to the outlet of the FPLC mixing chamber with the M-6 black nut. See Fitting Adaptor Kit on page Reserve the free end of the orange tubing for the red Fingertight fitting that will connect into the cap of the packing device. Setting the Pressure Limit For Perfusion Chromatography or conventional HPLC systems: Set the pressure limit of your system at 3,000 psi. For medium-pressure systems: Set the pressure limit at the maximum allowable on the system. For example, on an FPLC system, set the pressure limit at 4.0 MPa. Preparing the Pumps Flush the pumps and the outlet tubing with the packing solvent listed in Table 1. NOTE: On an FPLC system, you must flush both pumps with packing solvent because both pumps are used during packing. 3.5 Assembling the Packing Device and Empty Cartridge To assemble the packing device and cartridge for packing, do the following: 1. Locate the equipment needed for packing. See Lab Equipment Needed on page Write the name of your POROS Self Pack media on one of the blank labels provided with the media. These labels identify the cartridges and also identify the top of the cartridge (the end connected to the packing chamber). Use the top as the inlet end. Attach the label to an end fitting. Reserve this fitting to be the top end fitting. 3. Set the cartridge end fittings on the countertop so that you can look down into them. 4. Drop a frit into each end fitting. 5. Pick up one end fitting containing a frit. 6. Screw the cartridge tube into the end fitting until finger-tight. 7. Tighten the end fitting a little more: grip the cartridge tube with one hand and the end fitting in the other hand and tighten securely. 8. Screw the free end of the cartridge tube into the outlet end of the packing chamber. Tighten securely with two hands. 9. Set the unused end fitting aside. 10. Screw the backpressure regulator into the cartridge (see Figure 3 on page 4). 3.6 Positioning the Packing Device 1. Clamp the open packing device/cartridge assembly on the front of your LC instrument. If clamps are not available on the instrument, use a ring stand. Make sure that the following conditions are met: The packing device is positioned vertically. The pump outlet tubing can reach the top of the packing device. You can fit a 50 ml beaker under the end of the 2. Position your empty beaker below the end of the 3. Seat the packing chamber O-ring in the depression around the rim of the chamber opening (shown in Figure 1 on page 1). 3

4 4 Packing a Cartridge Figure 3 shows a packing device setup on a BioCAD /SPRINT System. The packing operation consists of five steps: Slurrying the media Filling the packing device Packing the cartridge Removing and capping the packed cartridge Cleaning up 4.1 Slurrying the Media 1. Determine the weight or volume of media to add to the packing device (100 mg of dry media or 0.2 ml of wet settled media per cartridge). NOTE: With wet media of unknown volume, allow it to settle in a graduated test tube. Note the total volume (V t ) and the volume of settled media (V m). Calculate the volume in ml of resuspended media needed using the following equation: V = 0.2 x (Vt/Vm) 2. Add 5 ml of the appropriate slurry solvent (see Table 1 on page 3) to the media and mix. 4.2 Filling the Packing Device Caution: Do not proceed without setting your system pressure as described in Section 3.4, Preparing Your LC System. To fill the packing device, do the following: 1. Add the media slurry into the open packing device. 2. Rinse the pipette or cylinder with a small amount of slurry solvent to ensure that all of the slurry is added to the packing device. 3. Add slurry solvent to the packing device until it is completely full. NOTE: Do not stir up the slurry at the bottom of the packing device. Direct the slurry solvent so that it runs down the inner wall of the packing device, instead of pouring directly on the slurry. 4. Quickly screw the 2-piece cap onto the packing device: place the center cover on the chamber, thread the lock nut down over the cap and hand tighten until snug. Use a lab tissue to wipe any liquid that comes out through the top as you tighten the cap. PB Figure 3 Typical Packing Device Setup 5. Attach the pump outlet tubing from the LC system to the cap of the packing device. Finger tighten the fitting. 4.3 Packing the Cartridge This section discusses these topics: Principles of Packing Packing a Cartridge Using the INTEGRAL 100Q System, VISION or BioCAD Workstation, BioCAD/SPRINT System, BioCAD/RPM System, or FPLC system Packing a Cartridge Using Other Systems Principles of Packing Cap Packing chamber PEEK cartridge Backpressure regulator As a cartridge packs, the backpressure on the cartridge rises. The optimal packing flow rate is the highest flow rate possible that allows the following: Packing to proceed within the pressure limit you set earlier A sufficient volume of packing solvent to pass through the cartridge to ensure an efficient and stable bed The actual packing flow rate is dependent on the system used, the particle size of the media, and the length of the NOTE: Do not overtighten the cap. Overtightening can damage the threads of the chamber and the cap. 4

5 Packing a Cartridge Using the INTEGRAL 100Q System, VISION or BioCAD Workstation, BioCAD/SPRINT System, BioCAD RPM Workstation, or FPLC System NOTE: Monitor the highest sustained pressure that occurs during packing. Do not exceed this pressure when you run the packed To pack a cartridge, do the following: 1. Use a total volume of at least 25 ml packing solvent to pack the 2. Set the flow rate for packing the cartridge at 9 ml/min. 3. Turn on the flow and monitor the volume of packing solvent in the waste beaker below the If the pressure is below the system limit increase the flow rate until a pressure of 2,000 psi is attained, or the maximum system flow rate is reached, whichever comes first. 4. Once at least 25 ml of packing solvent has passed through the cartridge and a constant pressure has been reached, stop the flow. 5. Let the cartridge sit for 3 minutes to allow the pressure to dissipate evenly across the packed bed. NOTE: The packing flow rate has been determined to allow you to pack your cartridge within the pressure limit of your system. However, variations in frit permeability or system backpressure may require you to adjust the flow rate slightly. 6. If your system is well below the pressure limit during packing, increase the flow rate in 0.5 ml/min increments until you approach the pressure limit. Pack cartridges at the highest flow rate possible without exceeding the system pressure limit. 7. If you reach the pressure limit before you finish packing the cartridge, stop the flow, restart the flow at 0.5 ml/min lower than the original setting, and continue packing. Repeat if necessary until you are able to pack the cartridge within the pressure limit. NOTE: Occasionally a defective frit generates excessive backpressure. If so, replace both frits and start again. 8. Record the highest sustained pressure that occurred during packing. Do not exceed this pressure when you run the packed Packing a Cartridge Using Other Systems NOTE: Monitor the highest sustained pressure that occurs as you pack the Do not exceed this pressure when you run the packed If you are using systems other than the INTEGRAL Micro Analytical Workstation, VISION or BioCAD Workstation, BioCAD/SPRINT System, BioCAD RPM System, or FPLC system, you need to experiment to find the correct flow rate. Start by setting the flow at either 9 ml/min or the maximum allowable on the system, whichever is lower. When using other systems to pack the cartridge, note the following: 1. Use a total volume of at least 25 ml packing solvent to pack the 2. Turn on the flow and monitor the volume of packing solvent coming through the cartridge by observing the level in the waste beaker below the 3. If you reach the pressure limit before the required volume of packing solvent passes through the cartridge, stop the flow, restart the flow rate at 0.5 ml/min lower than the original setting, and continue packing. 4. If the pressure limit is again exceeded, lower the flow rate another 0.5 ml/min. 5. Continue lowering the flow rate in 0.5 ml/min increments until at least 25 ml of packing solvent passes through the cartridge and you reach a constant pressure; then, stop the flow. NOTE: Occasionally a defective frit generates excessive backpressure. If so, replace the frits and start again. 6. Let the cartridge sit for 3 minutes to allow the pressure to dissipate evenly across the packed bed. 7. Record the final flow rate. Use this flow rate the next time you pack a cartridge with your system. 8. Record the highest sustained pressure that occurred during packing. Do not exceed this pressure when you run the packed 4.4 Removing and Capping the Packed Cartridge To remove the cartridge, do the following: 1. Remove the backpressure regulator from the 2. Loosen the end fitting on the cap of the packing device to release the pressure in the 3. Unscrew the cartridge from the packing device. Grasp the bottom end fitting of the (Turn slowly at first to make sure the end fitting does not unscrew from the cartridge body.) Turn the cartridge to the left to unscrew it. A small bubble of excess packing material may cover the top end of the cartridge tube. If the material is wet, lightly touch the bubble with a lab tissue or paper towel to draw off the moisture. 4. Draw the flat side of the spatula across the top of the cartridge to remove the excess material and to level off the top of the packed bed. 5. With a damp tissue, carefully wipe any remaining packing material from around the rim at the top of the cartridge tube. Do not touch the top of the packed bed itself. 6. Holding the unused end fitting upright to ensure that the frit remains seated, turn the packed cartridge upside down and screw it into the end fitting. Keep track of the cartridge inlet end. 7. Tighten the end fitting with both hands. 8. Insert the end plugs into the cartridge end fittings. 9. Set the cartridge aside while you clean up from the packing procedure. 5

6 4.5 Cleaning Up To clean up, do the following: 1. Make sure an empty waste beaker is below the cartridge packing device. 2. Pump several milliliters of packing solvent through the packing device to push out excess packing material accumulated at the outlet end of the chamber. 3. Remove the connection at the top of the packing device. The pressure inside the packing device is released and the entire contents flush into the beaker. 4. Remove the packing device from the clamp, take off the cap, and clean all pieces thoroughly with water. 5. Rinse the threads at the outlet end to remove residual media. NOTE: The O-ring may stick to the cap of the packing device by surface tension. Use the spatula to pull it out. 5 Running the Packed Cartridge For information about running the packed cartridge, see the Performing Unlabeled Perfusion Immunoassays document provided. 6 Unpacking a Cartridge To unpack a cartridge, do the following: 1. Unscrew one end fitting and remove the frit. 2. Connect the other end of the cartridge to the pump outlet tubing of your LC system. 3. Position a beaker under the 4. Start the flow rate at 5 ml/min. 5. As soon as the media is pushed out of the cartridge into the beaker, stop the flow. 6. Remove the remaining end fitting. 7. Sonicate the tube, end fittings, and frits in 50% isopropanol, ethanol, or other alcohol for 10 minutes. Rinse all pieces thoroughly with deionized water. 7 Storing Packing Device and Cartridge Cartridge: To store a packed cartridge, see the cartridge Operating Instructions sheet included with your ID Self Pack media. To store an unpacked cartridge, keep the tube, end fittings, frits, and end plugs together. Packing Device: Store the packing device with the cap on to keep the threads from knocking against other equipment. If the threads are damaged, the device may not seal properly during packing. Also, damaged threads may cause the cap to lock in place irreversibly. Ideally, store the capped device in its original box. 8 Accessories, Spare Parts, and Ordering Information Table 2 Spare Parts and Accessories Description Quantity Part Number ID Self Pack Packing Device 1 ea Chemistry Trial Kit AD, AL, BA, EP, and XL Self Pack Media, with reagents and 5 empty cartridges 1 kit ID Sensor Cartridge Kits (cartridges with reagents) AD ID Sensor Kit 1 kit AL ID Sensor Kit 1 kit BA ID Sensor Kit 1 kit EP ID Sensor Kit 1 kit PA ID Sensor Kit 1 kit PG ID Sensor Kit 1 kit XL ID Sensor Kit 1 kit ID Sensor Cartridges (cartridges only) AD ID Sensor Cartridge 1 cartridge AL ID Sensor Cartridge 1 cartridge BA ID Sensor Cartridge 1 cartridge EP ID Sensor Cartridge 1 cartridge PA ID Sensor Cartridge 1 cartridge PG ID Sensor Cartridge 1 cartridge XL ID Sensor Cartridge 1 cartridge Self Pack Media AD (Adsorbed) 500 mg AL (Aldehyde) 500 mg BA (Streptavidin) 1 ml EP (Epoxide) 500 mg PA (Protein A) 1 ml PG (Protein G) 1 ml XL (Cross-linked Protein G) 1 ml Reagents Loading Buffer 1 pack Elution Buffer 1 pack AD ID Reagent Pack 1 set AL ID Reagent Pack 1 set EP ID Reagent Pack 1 set XL ID Reagent Pack 1 set Empty Cartridges 2.1 mmd/30 mml PEEK Pkg of mmd/30 mml PEEK Pkg of mmd/30 mml PEEK Pkg of Accessories, Packing Device Fitting Adaptor Kit 1 ea O-Ring 1 ea

7 Table 2 Spare Parts and Accessories (Continued) Description Quantity Part Number Accessories, Cartridge Frits, 2.1 mm PEEK Pkg of EZ Grip Fittings (SS) Pkg of 5 P Technical Support PerSeptive Biosystems is dedicated to helping you use Perfusion Chromatography and ID media to the fullest extent possible. Our biochromatographers, bioprocess engineers, and applications development laboratories are available for support ranging from telephone consultation to full method development. PerSeptive Biosystems offers a full line of ID media for Perfusion Chromatography in the reversed-phase, ion exchange, affinity, and other chromatographic modes. Please contact your PerSeptive Biosystems representative for technical and ordering information. PerSeptive Biosystems publishes a continuing series of Application and Technical Notes, highlighting specific purification solutions and technical aspects of Perfusion Chromatography. Please contact PerSeptive Biosystems directly for a publication list. For further details or for answers to questions on ID Self Pack, Perfusion Chromatography, or other products, please contact PerSeptive Biosystems. Refer to the back cover of this document for the number of the appropriate office. 7

8 PerSeptive Biosystems, POROS, Perfusion Chromatography, BioCAD, INTEGRAL, RPM, Self Pack, and the fractal icon are registered trademarks of PerSeptive Biosystems, Inc. ID, ImmunoDetection, SPRINT, and VISION are trademarks of PerSeptive Biosystems, Inc. Luer-Lok is a registered trademark of Becton-Dickinson and Company. Tris is a registered trademark of Rohm and Haas Company. FPLC is a registered trademark of Pharmacia Biotech AB. Teflon is a registered trademark of E. I. Du Pont de Nemours. EZ is a trademark of Scientific Systems, Inc. POROS products and perfusive chromatography are covered by US patents 5,019,270; 5,030,352; 5,228,989; 5,384,042; 5,552,041; 5,605,623; and 5,833,861; issued to PerSeptive Biosystems, Inc.; foreign patents pending. Chromatography materials of certain pore geometries, including wide-pore supports, can permit perfusive chromatography, that is, separations where the rate of intraparticle convection exceeds the rate of diffusion. Use of any such chromatography media that permit performance at high linear velocity, without license, constitutes infringement of US patent 5,019,270 and US patent 5,228,989. A limited license to use the patented perfusive chromatography process is granted with the purchase of POROS products from PerSeptive Biosystems. The license may not be transferred except with the transfer of POROS columns or media, and terminates upon expiration of the useful life of the product. Part Number , Rev. 2, 3/ Printed In USA Printed on recycled paper. PE Biosystems Headquarters 850 Lincoln Centre Drive Foster City, CA Tel: (650) Tel: (800) PerSeptive Biosystems Center of Excellence 500 Old Connecticut Path Framingham, MA Tel: (508) Tel: (800) For international office locations, please call the headquarters or refer to our web site at

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7 Old-Style Aging Cell 316 Stainless Steel - 500-mL Capacity Part No. 175-70 Instruction Manual Updated 8/21/2014 Ver. 1.7 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

Agilent Ultimate Union Kits (G and G )

Agilent Ultimate Union Kits (G and G ) Agilent Ultimate Union Kits (G3182-61580 and G3182-61581) Installation Guide The Agilent Ultimate Union (Figure 1) provides a high performance, easy to maintain connection method for capillary columns.

More information

INSTALLATION INSTRUCTIONS TOWNSEND

INSTALLATION INSTRUCTIONS TOWNSEND INSTALLATION INSTRUCTIONS TOWNSEND.00 DECK MOUNT BATH FILLER.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly-please

More information

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT 5951, 5961, 5981, 5983, 5993 SERIES MT122B INSTALLATION INSTRUCTIONS THESE INSTRUCTIONS MUST BE LEFT WITH HOMEOWNER WIDESPREAD LAVATORY MODELS WITH HI-ARC TRADITIONAL CROSS NOTE: Handle Inserts are not

More information

Filters for HPLC and UHPLC Columns

Filters for HPLC and UHPLC Columns Filters for HPLC and UHPLC Columns Provide economical protection from the harmful effects of sample and mobile phase particulates on modern UHPLC and other high resolution HPLC columns. Direct Connect

More information

Flow Splitter. Installation Instructions

Flow Splitter. Installation Instructions protecol Flow Splitter Installation Instructions Introduction The ProteCol Flow Splitter is designed to split conventional LC flow rates (250 µl/min to 8 ml/min) to achieve capillary LC flow rates (100

More information

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95) 1612P MODEL 1612P SLICER MODEL 1612P ML-104587 EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO 45374-0001 FORM 19370 (4-95) Installation, Operation, and Care of MODEL 1612P SLICER SAVE THESE INSTRUCTIONS

More information

Gas Go Anywhere /23/01

Gas Go Anywhere /23/01 Gas Go Anywhere 55014 02/23/01 FOR OUTDOOR USE ONLY This grill does not include an LP fuel tank. Check Package Contents You should have received the parts listed below. While we give much attention to

More information

FagronLab FG. Semi-automatic capsule filling machine. User Manual

FagronLab FG. Semi-automatic capsule filling machine. User Manual Semi-automatic capsule filling machine User Manual Table of contents 1. Introduction... 4 2. Service.. 4 3. Warranty... 4 4. Overview... 5 System features... 5 FagronLab FG-1 Filler Base & Orienter Base...

More information

Upchurch LOW PRESSURE FITTINGS AND CONNECTORS

Upchurch LOW PRESSURE FITTINGS AND CONNECTORS AND CONNECTORS Flangeless Fittings Upchurch Flangeless Fittings Upchurch Scientific Flangeless Fittings eliminate the need to flange tubing. This removable and reusable system provides several benefits:

More information

FORM (Apr. 2006)

FORM (Apr. 2006) 2212 Slcier MODEL 2212 SLICER MODEL 2212 ML-136132 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 35215 (Apr. 2006) Installation, Operation, and Care of MODEL 2212 Slicer

More information

Installation Instructions

Installation Instructions THE COLLECTION by Installation Instructions 0 BIDET FITTING Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please

More information

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E The Trimfast Ream Cutters are reliable, high performance cutters that will give you the results you need quickly

More information

Thomas Scientific Swedesboro, NJ U.S.A.

Thomas Scientific Swedesboro, NJ U.S.A. Thomas Scientific Swedesboro, NJ 08085-0099 U.S.A. Wiley Laboratory Mill, Model 4 3375-E10 (115 V, 50/60 HZ) USE AND CARE OF CATALOG NUMBER: 3375-E10 Wiley Laboratory Mill, Model 4 (115 V, 50/60 HZ) UNPACKING

More information

Type N550 Packing Removal/Replacement

Type N550 Packing Removal/Replacement Instruction Manual MCK-1155 Type N550 April 1981 Type N550 Packing Removal/Replacement! WARNING Only qualified servicemen should attempt to repair these valves. The skill required is similar to the complexity

More information

Access 2 Immunoassay System Supplies

Access 2 Immunoassay System Supplies Wash Buffer Can Replenish Wash Buffer Bottle Ready Running Paused Not Ready No None Float sensor detects when the internal reservoir is almost empty No further testing A full Wash Buffer Bottle installed

More information

GoBidet Bidet Attachment

GoBidet Bidet Attachment GoBidet Bidet Attachment 151 Ruths Place #5 Sequim, WA 98382 Tel 1-800-681-0753 Fax +1 360-681-4029 www.go-bidet.com MODEL #2003C In this box: 1 User Manual 1 GoBidet Unit w/ mounting bracket, nut, rubber

More information

BERYL Service Guide. Travel Adjust OTT Change

BERYL Service Guide. Travel Adjust OTT Change BERYL Service Guide Travel Adjust OTT Change SERVICE OVERVIEW This manual will guide you step by step performing a travel adjust and OTT setting change to your Beryl suspension fork. Please follow each

More information

Introducing EXP. the new gold standard of extreme pressure chromatography hardware and consumables.

Introducing EXP. the new gold standard of extreme pressure chromatography hardware and consumables. Introducing EXP the new gold standard of chromatography hardware and consumables. www.optimizetech.com/exp table of contents Welcome to the new gold standard of ultra high pressure liquid chromatography

More information

Operating Instructions

Operating Instructions Operating Instructions High Throughput Dialysis MODEL HTD96b www.htdialysis.com HTD96b : Operating Instructions Components Universal Base Unit Teflon block assembly: 9 Teflon bars, labeled sequentially

More information

JARVIS. Model 70 Airsnip Air Powered Scissors

JARVIS. Model 70 Airsnip Air Powered Scissors Air Powered Scissors EQUIPMENT SELECTION... Ordering No. Airsnip Model 70... 4019009 Air Filter/Regulator/Lubricator.. 3022003 Balancer... 1350084 Power--Pak (250 PSI)... 4026016 TABLE OF CONTENTS... Page

More information

General Laborator. Beakers, Low Form. Beakers, Low Form. Beaker Cups, Disposable Consumables General Plasticware

General Laborator. Beakers, Low Form. Beakers, Low Form. Beaker Cups, Disposable Consumables General Plasticware Beakers, Low Form PP, highly transparent Ideal for general laboratory use. With spout and exceptionally easy-to-read blue graduations. Good chemical resistance Resistant to heat up to 121 C (for 20 minutes),

More information

Ceramic Probe Replacement Instructions Accessory G

Ceramic Probe Replacement Instructions Accessory G Ceramic Probe Replacement Instructions Accessory G6600-60035 Purpose The Stainless Burner has two ceramic combustion tubes, which require periodic replacement: an inner and an outer tube. Scope This procedure

More information

COOPER FREESTANDING TUB FAUCET INSTALLATION

COOPER FREESTANDING TUB FAUCET INSTALLATION SKU(s): 940972 COOPER FREESTANDING TUB FAUCET INSTALLATION BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no

More information

Urea/Adblue Hose Reel

Urea/Adblue Hose Reel www.scintex.com.au sales@scintex.com.au Model: SHR3408 Urea/Adblue Hose Reel Product Manual Specifications Spring driven drum: for automatic rewind. Locking ratchet: to maintain the desired length of hose

More information

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER EDGE12 SLICER THE EDGE12 SLICER MODEL EDGE12-1 (120/60/1 voltage) EDGE12-2 (220/50/1 voltage) ML-136246 ML-136247 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 35283 (July

More information

9 LABORATORY ACCESSORY

9 LABORATORY ACCESSORY 9 NORMAG - LABORATORY GLASSWARE L 309 e.1 DRYING TUBES They serve for drying of gas with suitable desiccants. To avoid sticking of the packing during the process, not shape resistant desiccants (e.g. phosphorus

More information

SPECIFICATIONS. For 1 8 OD Tubing FERRULES FOR 1 8 OD TUBING. One piece PTFE ferrule with SS casing1. One piece PTFE ferrule with SS casing2 008FT32

SPECIFICATIONS. For 1 8 OD Tubing FERRULES FOR 1 8 OD TUBING. One piece PTFE ferrule with SS casing1. One piece PTFE ferrule with SS casing2 008FT32 4 OMNI-LOK FITTING SYSTEMS OMNI-LOK TYPE P For 1 16, 1 8 or 3 16 OD semi-rigid tubing and ¼ -28 UNF, M6 or 5 16-24 UNF threaded flat-bottom ports Pressure rated up to 1000psi (69 bar) when hand-tight High

More information

300 ft. 5/8 Hose wagon

300 ft. 5/8 Hose wagon 300 ft. 5/8 Hose wagon Model 95956 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. (Garden hose is not included).

More information

AssayMAP Bravo Syringe Replacement

AssayMAP Bravo Syringe Replacement AssayMAP Bravo Syringe Replacement User Guide Original Instructions Agilent Technologies Notices Agilent Technologies, Inc. 205 No part of this manual may be reproduced in any form or by any means (including

More information

Reverse Osmosis system 50 GPD Instruction manual EN

Reverse Osmosis system 50 GPD Instruction manual EN Reverse Osmosis system 50 GPD Instruction manual EN Contents 1. Unpacking 2. Scope of supply 3. Insertion of the membranes 4. Connecting the lines 5. Installation 6. First commissioning 7. Consumables

More information

A Pre-Paid Return Label is included (optional) *Call for pick up no later than the above return date to avoid additional rental fees

A Pre-Paid Return Label is included (optional) *Call for pick up no later than the above return date to avoid additional rental fees TM TRACE AnalyticsLLC the compressed air testing experts the AirCheck Lab YOUR AIRCHECK for AirCheck TM Kit KX00PR TM NOTEBOOK RENTAL PROGRAM RENTAL PERIOD *RETURN DATE A Pre-Paid Return Label is included

More information

Instructional Booklet

Instructional Booklet Instructional Booklet 936-894-3292 Thank you for choosing The Bathmaster! You are on your way to creating an unmatched bathing experience both for you and the lucky animal. The Bathmaster is designed to

More information

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility IB 15/120 The Ice Blaster IB 15/120 is one of the most powerful dry ice blasting machines on the market. It impresses with its robustness, highly reliable technology and the best results in dry ice cleaning.

More information

Big SHOT III Hybridization Oven

Big SHOT III Hybridization Oven Big SHOT III Hybridization Oven Models 230402 and 230402-2 Whether you are working with Northern Blots, Southern Blots, Microarrays or another application that requires incubation, you will find the Big

More information

CONVERSION INSTRUCTIONS

CONVERSION INSTRUCTIONS CONVERSION INSTRUCTIONS Natural Gas to Propane Gas Conversion Kit For Thermador Professional Cooktops and Ranges Model STARLPKIT Part No. 35-00-682 Contains 7mm Hex Main Orifices This kit is used to convert

More information

Otter Pro XT Cabin Installation and Set-Up Instructions

Otter Pro XT Cabin Installation and Set-Up Instructions Otter Pro XT Cabin Installation and Set-Up Instructions Otter Pro XT Cabin Fits Medium Otter Pro and Otter II Sled Only Parts Identification and Check List MODEL NUMBERS: Complete Pkg Pro XT Thermal Cabin

More information

Operating Instructions

Operating Instructions Operating Instructions High Throughput Buffer Exchange or Desalting Dialysis MODEL HTD12a www.htdialysis.com HTD12a : Operating Instructions Components Pressure Plate Clamp In Closed Position Place Stainless

More information

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets SAVE FOR END USER ELKAY 2222 CAMDEN COURT OAK BROOK, IL 60523 USA WALL MOUNT ASSEMBLY General Instructions Turn off the water

More information

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 707.773.1100 Fax 707.773.1180 www.gcx.com Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End Products covered

More information

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374 I N ST R UC 1712E T I ON MODELS 1612E, 1712E & 1712RE SLICERS S ML-104546 ML-104547 ML-104548 1612E 1712E 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374 FORM 19238 Rev. B (10-97) TABLE OF CONTENTS GENERAL......................................................................

More information

Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual

Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual 27.75 23.75 25.50 20.75 Specifications: 8-13 GPM 12-14 VAC only (Class 2 transformer required) 3W max. 100 ft. cord, conduit

More information

VEPR Round Drum Disassembly and Assembly

VEPR Round Drum Disassembly and Assembly VEPR 12 25 Round Drum Disassembly and Assembly Required Tools ¼ Allen Wrench Flat Head Screwdriver Drum Parts List Drum Body Carousel Center Bolt Dummy Rounds Carousel Lock Spring Clear Drum Cover Step

More information

Advantage Plus TIM-3600 Series Reel

Advantage Plus TIM-3600 Series Reel Read the following precautions and instructions before you begin assembly or using. Failure to comply with these instructions could result in personal injury or property damage. Keep these instructions

More information

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO 1-800-862-2731 Administration of Micafungin Using Minibag Plus & DIAL-A-FLO Drug Name: Volume and Rate: Schedule: KEY POINTS: FLUSHING: Saline Drug Saline Heparin 1. Always wash your hands with an antibacterial

More information

Contents. Company Background FLOWSTOPPER Plugging Device Kit and Replacement Parts Key Features & Benefits... 4

Contents. Company Background FLOWSTOPPER Plugging Device Kit and Replacement Parts Key Features & Benefits... 4 Contents Company Background... 2 FLOWSTOPPER Plugging Device Kit and Replacement Parts... 3 Key Features & Benefits... 4 Frequently Asked Questions... 5 Step by Step Instructions... 6 FLOWSTOPPER Warranty...

More information

SERVICE MANUAL- M126

SERVICE MANUAL- M126 SERVICE MANUAL- MANUAL CAN OPENER- MODEL # 2 1 Model #2 Can Opener Assembly Procedure The Model #2 can opener will be assembled according to the following procedure. I. Model #2 Handle and Arbor Assembly

More information

Otter XT Cabin Installation and Set-Up Instructions

Otter XT Cabin Installation and Set-Up Instructions Otter XT Cabin Installation and Set-Up Instructions Otter XT Cabin Fits Medium Otter Wild Sled Only Parts Identification and Check List MODEL NUMBERS: Complete Pkg Otter XT Cabin 200962 2 1 PARTS LIST

More information

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001 BAG-TO-BAG FILTER KIT UN GRN LINE WATER FLOW USER MANUAL Model Number 67252 EPA Est. No 71766-UT-001 EMERGENCY BAG TO BAG FILTER KIT INTRODUCTION Thank you for purchasing the WaterBasics Bag to Bag Emergency

More information

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE Table of Contents TEACHER S MANUAL Overview....3 Objectives............................................................. 3 Correlation to Science Standards...3

More information

4A1-114/114KR & 4A1-2 MANUAL TENSIONERS

4A1-114/114KR & 4A1-2 MANUAL TENSIONERS M L. C O O N AL TO 4A1-114/114KR & 4A1-2 W W W.T R AD IT IO MANUAL TENSIONERS READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE PERSONAL INJURY. GENERAL SAFETY

More information

ASSEMBLY & CARE INSTRUCTIONS

ASSEMBLY & CARE INSTRUCTIONS ASSEMBLY & CARE INSTRUCTIONS 7 x TRAILER TENT SERIES 3 9 Part No. FT3711 - on road FT3923 - off road OPTIONAL SUNROOM Wall and floor kit Part No. FT3723 - on road FT39 - off road OPTIONAL SPARE ROOM Roof,

More information

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G) Part B, ection Model Voltage This section covers the following unit configurations. 3400V All Pump Piston Pump (E or G) Manifold Control 4-Port (A) Vista tandard (V) Vista Pattern (PC) Vista Temperature

More information

LBH18BPK. Instruction Sheet

LBH18BPK. Instruction Sheet LBH18BPK Instruction Sheet Included: 1. Backpack (includes belt and pouch) 2. Bottle and Hose Attachment Assembly 3. 1 each disposable 1.5 gallon Chemical Storage Bag 4. 1 each 1.5 gallon Warm Water Cleanout

More information

BowDown. MiniMuM Crossbar spread 24 (61CM) Steel Hook (2X) Buckle Strap (2X) Plastic Tube (2X) Plain Strap (2X) SHORT BLACK T-BOLT (2x) BOWDOWN (2x)

BowDown. MiniMuM Crossbar spread 24 (61CM) Steel Hook (2X) Buckle Strap (2X) Plastic Tube (2X) Plain Strap (2X) SHORT BLACK T-BOLT (2x) BOWDOWN (2x) BowDown MiniMuM Crossbar spread 24 (61CM) Heavy Duty strap (2x) SHORT BLACK T-BOLT (2x) BOWDOWN (2x) Bow Stern Tie Down Buckle Strap (2X) Plastic Tube (2X) Plain Strap (2X) Steel Hook (2X) IMPORTANT WARNING

More information

How to Use Your Implanted Venous Port

How to Use Your Implanted Venous Port Your implanted port is a special intravenous (IV) device that has been placed so you can receive IV medications and fluids. It is made up of a small chamber with a self-sealing silicon septum attached

More information

Assembly TOOLS REQUIRED: 17mm and 14mm or equivalent wrenches.

Assembly TOOLS REQUIRED: 17mm and 14mm or equivalent wrenches. Instructions for 3 Trimmer Rack, 3TR* *Patents Pending Assembly TOOLS REQUIRED: 17mm and mm or equivalent wrenches. 15 26 26 16 15 16 Attach the lower mounting brackets to the Trimmer Rack poles as shown

More information

Sealing and terminating Wrexham Mineral Cables

Sealing and terminating Wrexham Mineral Cables Sealing and terminating Wrexham Mineral Cables A Termination is required at both ends of each length of cable, and it should be fitted as soon as the cable has been prepared. A complete termination consists

More information

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0 ASSEMBLY AND OPERATIONAL INSTRUCTIONS The remote swabbing and microbiological sampling tool and the Teflon template tool are shipped partially assembled. Complete assembly instructions are provided below:

More information

Cold Water Rheology Kit

Cold Water Rheology Kit Cold Water Rheology Kit Instruction Manual Manual No. 372144, Revision E Instrument No. 207952 or 207953 Fann Instrument Company Cold Water Rheology Kit Instruction Manual 2012 Fann Instrument Company

More information

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL BRIEF INTRODUCTION Split body (2-piece) valve allows easy replacement of gasket, seal, and seats without special tools. Series 90D ball valves use floating ball design. Induced by the line pressure the

More information

ASSEMBLY & CARE INSTRUCTIONS. 7 x4 TRAILER TENT SERIES 4 9. OPTIONAL SUNROOM Wall and floor kit. OPTIONAL SPARE ROOM Roof, wall and floor kit

ASSEMBLY & CARE INSTRUCTIONS. 7 x4 TRAILER TENT SERIES 4 9. OPTIONAL SUNROOM Wall and floor kit. OPTIONAL SPARE ROOM Roof, wall and floor kit ASSEMBLY & CARE INSTRUCTIONS 7 x TRAILER TENT SERIES 9 Part No. TM709 OPTIONAL SUNROOM Wall and floor kit Part No. TM723 OPTIONAL SPARE ROOM Roof, wall and floor kit Part No. TM76 Please keep these instructions

More information

HZS Field Spectroscopy Kit

HZS Field Spectroscopy Kit HZS Field Spectroscopy Kit General Description The HZS Field Spectroscopy Kit is designed for hazmat responders, military, police or forensic personnel to enable: hands free carrying of portable Raman

More information

Blue Series Hot Melt Hose with RediFlext II Hanger System

Blue Series Hot Melt Hose with RediFlext II Hanger System Instruction Sheet P/N 1124594_01 Blue Series Hot Melt Hose with RediFlext II Hanger System Safety WARNING! Allow only personnel with appropriate training and experience to operate or service the equipment.

More information

Installing the Agilent 6890 Oven Insert for Fast Chromatography

Installing the Agilent 6890 Oven Insert for Fast Chromatography Installing the Agilent 6890 Oven Insert for Fast Chromatography Kit G2646-60500 The 6890 Oven Insert for Fast Chromatography reduces the oven volume so that the column and sample heat more quickly, yielding

More information

Mixpac TM B-System Application System for 2-Component Products 25 ml, 50 ml and 75 ml

Mixpac TM B-System Application System for 2-Component Products 25 ml, 50 ml and 75 ml Sulzer Chemtech Mixpac TM B-System Application System for 2-Component Products 25 ml, 50 ml and 75 ml 0611 4407-11 MIXPAC B-System: Process safety, Precision, Added value The Sulzer Mixpac B-System meets

More information

# For 500 ml Aging Cells # For 260 ml Aging Cells. Instruction Manual. Updated 6/20/2016 Ver. 4.0

# For 500 ml Aging Cells # For 260 ml Aging Cells. Instruction Manual. Updated 6/20/2016 Ver. 4.0 Teflon Liner for Aging Cells #175-60 - For 500 ml Aging Cells #175-60-6 - For 260 ml Aging Cells Instruction Manual Updated 6/20/2016 Ver. 4.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston,

More information

S E L E C T I O N. Abdominal Crunch. User manual

S E L E C T I O N. Abdominal Crunch. User manual and S E L E C T I O N T H E S T R E N G T H E V O L U T I O N User manual and and The identification plate of the and manufacturer, affixed along side the seat on the frame of the weight stack, gives the

More information

MAX Series 9514 OPERATOR S MANUAL

MAX Series 9514 OPERATOR S MANUAL MAX Series 9514 OPERATOR S MANUAL Persons under age 18 are not permitted to operate or have accessibility to operate this equipment per U.S. Dept. Of Labor Employment Standards Administration Fact Sheet

More information

300 Model 870 Four Wheel Hose Cart Owner s Manual

300 Model 870 Four Wheel Hose Cart Owner s Manual 300 Model 870 Four Wheel Hose Cart Owner s Manual IMPORTANT: READ THE OWNER S MANUAL BEFORE ASSEMBLING TOOLS REQUIRED: TWO ADJUSTABLE WRENCHES; HAND PUMP Estimated assembly time: 30 minutes PARTS LIST

More information

Gosford Aquifier (Pre 2009) Replace O-rings here

Gosford Aquifier (Pre 2009) Replace O-rings here Gosford Aquifier (Pre 2009) Replace O-rings here Gosford Aquifier (Pre 2009) General Advice: These instructions are intended as a guide only, if you are in any doubt you should seek the advice of a qualified

More information

BARE FIBER OPTIC TERMINATOR

BARE FIBER OPTIC TERMINATOR BARE FIBER OPTIC TERMINATOR Reusable Terminator for Single Mode and Multimode Fiber FC/PC, FC/APC, SMA905, ST /PC, SC/PC, or LC/PC Compatible Connectors Terminator Accepts Bare Fiber up to Ø1400 µm Application

More information

APPENDIX A LIGHT SOURCE

APPENDIX A LIGHT SOURCE APPENDIX A LIGHT SOURCE GASOLINE LANTERN One source of artificial light for the field kitchen is the gasoline lantern (NSN 6260-00-170-0430). It is a one-mantle lantern with a heat-resistant globe or globe

More information

* * KR54-F, KR9854 & KR9954 Installation Instructions. Read All Warnings Before Starting Installation! Index:

* * KR54-F, KR9854 & KR9954 Installation Instructions. Read All Warnings Before Starting Installation! Index: *941061-00* 941061-00 Keyed Removable Mullion KR54-F, KR9854 & KR9954 Installation Instructions CLASSIFIED CLASSIFIED C Read All Warnings Before Starting Installation! Index: General Information ----------------

More information

Titan3 Syringe Filters. Sample Preparation 1-036

Titan3 Syringe Filters. Sample Preparation 1-036 Sample Preparation Titan3 Syringe Filters Low extractable membranes and housing HPLC performance tested Color coding for easy selection of the correct membrane and pore size Enhanced Luer Lock inlet which

More information

Your Artificial Lift Experts. Oilfield Equipment. upcglobal.com

Your Artificial Lift Experts. Oilfield Equipment. upcglobal.com Your Artificial Lift Experts Oilfield Equipment upcglobal.com Your Artificial Lift Experts Oilfield Equipment upcglobal.com No. 142 Stringing-Up Link No. 14 Triangle C Link The Stringing-up link is used

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES IMPORTANT: To ensure this product is installed properly, you must read and follow these guidelines. The owner/user of this product must keep this information for future reference. This product must be

More information

IB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display

IB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display IB 7/40 Classic Thanks to airflow optimisations, our Ice Blaster IB 7/40 impresses with excellent results during dry ice cleaning, even when working with low air pressures. Compact device. 1 Automatic

More information

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series Connector Piece Parts LC Simplex Connector Boot LC Duplex Connector LC Connector CriMp Tulolng LC Duplex Clip Boot 86001-0110, Rev. B USN30MFO/5/2010 Procedure Chart Procedure Tool Required Tool Part Number

More information

Model 205 Fireview Maintenance Kit

Model 205 Fireview Maintenance Kit Model 205 Fireview Maintenance Kit Please read all of the instructions before you begin the procedure. Confirm that you have all the necessary tools and parts required. Allow about one hour to complete

More information

2100 Series Series Emergency Pressure Relief Vent and Manhole Cover. North America Only. Table of Contents. Introduction. Scope of the Manual

2100 Series Series Emergency Pressure Relief Vent and Manhole Cover. North America Only. Table of Contents. Introduction. Scope of the Manual Instruction Manual D103823X012 September 2017 Emergency Pressure Relief Vent and Manhole Cover Table of Contents Introduction...1 Specifications...2 Product Identification and Marking...3 Principle of

More information

SOLHARO ASSEMBLY & INSTALLATION INSTRUCT IONS

SOLHARO ASSEMBLY & INSTALLATION INSTRUCT IONS A. Introduction: SOLHARO ASSEMBLY & INSTALLATION INSTRUCT IONS Rev. 01/30/2012 The Solharo is an external, retractable, tensioned sun shading system designed to fit over a sunroom or wood pergola. The

More information

Crimp & Cleave Termination Instructions for 200 µm F07 Connectors

Crimp & Cleave Termination Instructions for 200 µm F07 Connectors Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for 200 µm F07 Connectors For Use With: F07 Termination Kits 200 µm HCS Fiber-Optic Cable F07 Crimp & Cleave Connectors Important

More information

Otter Pro X-Over Lodge Installation and Set-Up Instructions

Otter Pro X-Over Lodge Installation and Set-Up Instructions Otter Pro X-Over Lodge Installation and Set-Up Instructions Otter Pro X-Over Lodge Fits Magnum Otter II & Pro Sled Only Parts Identification and Check List MODEL NUMBERS: Complete Pkg Pro X-Over Lodge

More information

Operating Instructions

Operating Instructions Operating Instructions Medium and High Pressure Model Numbers: RT602- RT635- RT602- RT635- RT603- RT650- RT603- RT650- RT605- RT825- RT605- RT650-SM RT802- RT835- RT425- RT803- RT402- RT435- RT625- RT403-

More information

VALORE SEVEN. Serial Number. Pacific) Version No.:V

VALORE SEVEN. Serial Number. Pacific) Version No.:V VALORE SEVEN Version No.:V.206222 Serial Number Pacific) 7 9 8 " 5 8 " " 7 2 8 " 26 2 " 7 8 " 9" 2 8 " 2 8 " (H) 26.9" x (W) 8.26" x (D) 8.85" Hand shower hose: 59.05" Weight: Net: 0 lbs /Gross: 2 lbs

More information

Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves

Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves Instruction Manual Graphite Packing for Sliding-Stem Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Storage and Startup...

More information

Hose Reel Series L701/G701

Hose Reel Series L701/G701 Hose Reel Series L70/G70.0 WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal

More information

FORM Rev. A (Feb. 2004)

FORM Rev. A (Feb. 2004) 2812B SLICER MODEL 2912B SLICER MODEL 2912B SLICER MODEL 2912B ML-134251 ML-134252 Previous models covered by this manual: 2912B ML-134123 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com

More information

Tools. For safety and easy faucet replacement, San-Ei recommends the use of the following helpful tools:

Tools. For safety and easy faucet replacement, San-Ei recommends the use of the following helpful tools: BW-0BH INSTALLATION INSTRUCTIONS SINGLE HANDLE Kitchen Faucet Tools For safety and easy faucet replacement, San-Ei recommends the use of the following helpful tools: SAFETY GLASSES PIPE WRENCH PLIERS CHANNEL

More information

Model 698/ and Model in 1 Hose Reel Owner s Manual

Model 698/ and Model in 1 Hose Reel Owner s Manual Model 698/694 200 and Model 706 100 4 in 1 Hose Reel Owner s Manual 698/694 706 VISIT OUR WEBSITE: WWW.LIBERTYGARDENPRODUCTS.COM OR CALL US TOLL FREE AT 1-866-820-5805 LIBERTY GARDEN PRODUCTS, INC. 500

More information

Teflon Liner for Aging Cells

Teflon Liner for Aging Cells Teflon Liner for Aging Cells DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion fluids,

More information

NEWMAR SERVICE SCHOOL

NEWMAR SERVICE SCHOOL NEWMAR SERVICE SCHOOL TRAINING INFORMATION GUIDELINE FOR FEBRUARY 2013 OUR PRODUCTS: NOVA DUAL PITCH AWNING G-2000/ G-1500 2 P a g e G-2085 G-5000 3 P a g e G-LINKS 4 P a g e NOVA/ G-2000/ G-1500 BASIC

More information

Water Filtration & Purification System

Water Filtration & Purification System INSTALLATION AND OPERATION INSTR UCTIONS FOR Series 200 High Flow Water Filtration & Purification System Table of Contents A. General Information B. Specifications C. Component Description D. Installation

More information

Gas Conversion Kits and Instructions

Gas Conversion Kits and Instructions Gas Conversion Kits and Instructions INSTALLATION FORM RGM 432/433-GC (Version D.1) Obsoletes Form RGM 432/433-GC (Version D) APPLIES TO: Model FT and Model SFT All gas conversion must be done by a qualified

More information

filtration at its finest Thermo Scientific Nalgene Syringe Filters

filtration at its finest Thermo Scientific Nalgene Syringe Filters filtration at its finest Thermo Scientific Nalgene Syringe Filters small filters. big results. Thermo Scientific Nalgene Syringe Filters are available in a variety of sizes and membranes for both sterile

More information

Corning Aspirator Instruction Manual

Corning Aspirator Instruction Manual Corning Aspirator Instruction Manual Corning Aspirator Table of Contents Introduction.............................. 1 Set Up.................................... 1 Proper Use................................

More information

HOSE ASSEMBLY CLEANLINESS

HOSE ASSEMBLY CLEANLINESS November 18, 2002 HOSE ASSEMBLY CLEANLINESS Preface Hydraulic system cleanliness is a term used to describe the level of solid and liquid contamination found in hydraulic systems. Contamination may be

More information

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

Evaluation copy. Fecal Coliform. Computer INTRODUCTION Fecal Coliform Computer 9 INTRODUCTION The concentration of fecal coliform bacteria in water is measured to determine the likelihood of contamination by microbiological organisms. While fecal coliform

More information

Introduction TEFLON PFA Filtration

Introduction TEFLON PFA Filtration Introduction TEFLON PFA Filtration The following pages are devoted to in-line filtration devices. Designs follow the popular 47 and 50 holders manufactured the past 23 years by Savillex Corp. Typical applications

More information