ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor

Size: px
Start display at page:

Download "ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor"

Transcription

1 PRODUCT SPECIFICATIONS AIR HANDLERS CBA7UHE ELITE Series R-0A - Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 067 October 07 Supersedes April 07 MODEL NUMBER IDENTIFICATION CB A 7 UH E Unit Type CB = Air Handler Nominal Capacity -. to Tons Optional Electric Heat -. to kw Minor Revision Number Refrigerant Type A = Aluminum Coil/R-0A Series Configuration UH = Upflow/Horizontal Blower E = High Efficiency Constant Torque Blower Motor Nominal Cooling Capacity - Tons 08 =. tons 0 = tons 00 =. tons 06 = tons 0 =. tons 08 = tons 060 = tons Refrigerant Metering Device = Fixed Orifice = TXV - Bleedport (indoor unit) = TXV - Non-bleedport (indoor unit) = TXV - Non-bleedport (outdoor unit) 6 = TXV - R-0A Non-bleedport (indoor unit) Voltage 0 = 08/0V- phase-60hz 60 = 60V- phase-60hz Can be used with 7V (step-down transformer required)

2 FEATURES CONTENTS Blower Data... 8 Dimensions... Electrical Data... 6 Electric Heat Data... 0 Features... Installation Clearances With Electric Heat... Model Number Identification... Optional Accessories... 6 Replacement Breakers... 9 Specifications... 6 F H B E G WARRANTY All covered components - five years in residential applications, one year in non-residential applications Refer to Lennox Limited Warranty Certificate included with each unit for additional details. APPROVALS Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with AHRI Standard 0/0. Optional electric heaters are rated in accordance with US Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations. Blower performance data according to unit tests conducted in Lennox air test chamber. Air handlers are UL Listed to US and Canadian safety standards and components within are bonded for grounding to meet safety standards for servicing required by CEC and NEC. Air handler units are approved for installation in manufactured housing and mobile homes. ISO 900 Registered Manufacturing Quality System. APPLICATIONS. to ton nominal sizes. Upflow or horizontal applications. Downflow applications with optional conversion kit. Applicable to expansion valve systems in cooling applications and check and expansion valve systems in heat pump applications. Wide-range check and expansion valve is factory installed. See bulletins in section Air Conditioners for cooling capacities. See bulletins in section Heat Pump Outdoor Units for cooling and heating capacities. Optional field installed electric heaters available in several sizes for additive heating capacity. B C D I D REFRIGERANT SYSTEM Lennox Quantum Coil Enhanced aluminum alloy tube/enhanced fin coil for superior corrosion resistance. Lennox designed and fabricated coils. Aluminum tubing, hairpins, distributor and header tubes. Ripple-edged aluminum fins. C Twin coil construction assembled in a A configuration for large surface area. Provides excellent heat transfer and low air resistance for maximum efficiency. Precise circuiting for uniform refrigerant distribution. Lanced fins provide maximum exposure of fin surface to air stream. Rifled tubing provides superior heat transfer. Coil thoroughly factory tested under high pressure to ensure leakproof construction. Refrigerant Line Connections Copper refrigerant sweat connections on both liquid and suction lines for easy brazing. Lines extend outside of the cabinet for ease of connection. See dimension drawings for locations. Check and Expansion Valve Furnished For use with R-0A systems. Wide range valve with Chatleff style fitting. Factory installed on all models, internal to cabinet. CBA7UHE / Page

3 E F G FEATURES BLOWER Power Saver Constant Torque Blower Motor Programmable high efficiency multi-speed blower motor. By maintaining constant torque output, blower motor can deliver more uniform (but not constant) airflow over the static pressure range. Programmable multi-speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Leadless blower motor features simple plug-in connections. Choice of blower speeds is available. See Blower Data tables. Blower speed change is easily accomplished by a simple wiring change. Blower Assembly Lennox designed and built, direct drive blower. Each blower is statically and dynamically balanced as an assembly before installation in the unit. Blower motor is resiliently mounted to blower assembly. Blower slides out of cabinet for servicing. CABINET Constructed of heavy-gauge galvanized steel. Completely insulated with thick fiberglass insulation. Pre-painted steel cabinets have mildly textured enamel finish with primer coat on unpainted side of all panels. Units are shipped in one piece but may be disassembled into two separate sections for ease of installation in tight applications. See dimension drawings. Thick rubber gasket between sections of the two piece cabinets provides an air tight seal. No external screw heads on sides of cabinet for tight installations without damage to walls or woodwork. Removable panels provide complete service access. Electrical inlets provided in sides and top of cabinet. See dimension drawings for locations. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard 9-00 Method of Test for Determining the Air Tightness of HVAC Equipment. Upflow/Horizontal Capability (Optional Downflow) Shipped for upflow and horizontal left-hand discharge. May be field converted to horizontal right-hand air discharge by repositioning horizontal drain pan. Optional downflow kit available for field conversion. Dual Position Drain Pans Drain pans designed for upflow, downflow or horizontal applications. Deep, corrosion resistant plastic drain pans have dual pipe drains. See dimension drawings. Optional Accessories Downflow Combustible Flooring Floor Base Base is required for models with electric heat installed in downflow position on combustible floors. Downflow Conversion Kit Required for field conversion to downflow position. Kit consists of drip shields and brackets for repositioning coil and drain pan. See Specifications table. Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of () x -/ x -/8 in. and () x x -7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. Side Return Unit Stand (Upflow Only) Raises unit 6 in. above floor for side return air duct connection. Eliminates need for wooden platform construction. All aluminum construction. Two adjustable frames fit -08/0 thru -060 models. Wall Hanging Bracket Kit (Upflow Only) Allows unit to be hung on wall at any height. Consists of heavy-gauge steel support brackets (one for air handler, one for wall mount). Screws furnished for fastening one bracket to unit. Bolts for fastening one bracket to wall are field provided. High Performance Economizer (Commercial Applications Only) Designed for applications requiring outdoor air to be utilized in a commercial HVAC system. Allows the entry of fresh outdoor air for free cooling, reducing the requirement for mechanical cooling. Heavy gauge galvanized steel cabinet lined with thick fiberglass insulation. Mixed air sensor, outdoor air sensor and VAC transformer furnished. Approved for California Title building standards. ASHRAE compliant. See separate Product Specifications bulletin for additional information and available control and sensor options. CBA7UHE / Page

4 FEATURES CONTROLS Transformer and Blower Cooling Relay volt transformer with in-line fuse and blower cooling relay furnished as standard. Factory installed in the unit control box. Terminal strip furnished. Optional Accessories ComfortSense 700 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. Heat/ Cool. Auto-changeover. Controls humidity during cooling mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (furnished with outdoor unit) allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. See the ComfortSense 700 Product Specifications bulletin in the Controls section for more information. Dehumidification Relay Kit Required with ComfortSense thermostat. Provides dehumidification mode when used in conjunction with ComfortSense 700 thermostat. Used with single- or two-stage heat pumps and air conditioners. Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. CBA7UHE / Page H OPTIONAL ELECTRIC HEAT Field install internal to unit cabinet. Available in several voltages and kw sizes. See Electric Heat tables. Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life. Each element equipped with accurately located limit control with fixed temperature off setting and automatic reset. Supplemental thermal cutoff limit control, provides positive protection in case of excessive temperatures. Thermal sequencer relay brings elements on and off line, in sequence and equal increments, with time delay between each. Initiates and terminates blower operation. Heating control relay(s) furnished as standard. Control box and access cover constructed of heavy gauge galvanized steel. Factory assembled with controls installed and wired. Electric heat low voltage controls plug-in to air handler. Breaker Models ECB9-CB, -CB, -6CB, -8CB, -9CB, -0CB, -.CB, -CB, -0CB, -CB and -0CB (08/0V-ph) and ECB9-CB, -0CB and -CB (08/0V-ph) heaters are equipped with circuit breakers for overload and short circuit protection. Factory wired and mounted on electric heat unit. Current sensitive and temperature actuated. Manual reset. breakers qualify as disconnect means at unit in many areas, eliminate the need for field provided disconnect. Consult local electrical code in your area. NOTE - 60V- phase air handlers can be used in 7V applications. 7V electric heaters are shipped with a 7V to 60V step-down transformer. Optional Accessories Breaker Cover Kit Flexible plastic cover protects circuit breaker. Recommended in areas with high humidity or unconditioned areas to prevent nuisance tripping. Single-Point Power Source Control Box Control Box may be used with optional electric heat when single power supply is connected to multi-circuit electric heat. Field installs external to the unit cabinet on either side or top. Constructed of heavy gauge steel, baked enamel finish, prepunched mounting holes, electrical inlet knockouts, and terminal strip. Removable cover provides easy access. Dimensions (H x W x D) - 7 x 7 x in.

5 I FEATURES INDOOR AIR QUALITY Air Filter Tool-less access to filter area for quick and easy servicing. Disposable frame type filter furnished and factory installed in rails in cabinet. See Specifications tables for sizes. Optional Accessories Healthy Climate Germicidal UVC Light Germicidal lamp emits C-Band ultra-violet (UVC) energy at.7 nanometers, which is proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UVC germicidal light greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Surfaces must be cleaned prior to UVC light being installed. Available in volt and 0.0V-ph models. Air handlers have a factory provided knockout in the coil delta plate for mounting light within coil area. Shielding baffle is required when installing light above a non-uvc resistant component, such as a filter. Baffle must be ordered separately. INSTALLATION CLEARANCES WITH ELECTRIC HEAT Cabinet 0 inch (0 mm) To Plenum inch ( mm) To Outlet Duct within feet (9 mm) inch ( mm) Floor See Note # Service / Maintenance See Note # Units installed on combustible floors in the downflow position with electric heat require optional downflow combustible flooring base. Front service access - inches (60 mm) minimum. NOTE - If cabinet depth is more than inches (60 mm), allow a minimum of the cabinet depth plus inches ( mm). CBA7UHE / Page

6 SPECIFICATIONS General Data Model Number CBA7UHE-08 CBA7UHE-0 CBA7UHE-00 CBA7UHE-06 Nominal tonnage.. Connections Suction (vapor) line (o.d.) - in. sweat / / / / Liquid line (o.d.) - in. sweat /8 /8 /8 /8 Condensate - in. fpt () / () / () / () / Indoor Coil Net face area - ft Tube outside diameter - in. /8 /8 /8 /8 Number of rows Fins per inch Blower Wheel nominal diameter x width - in. 0 x 8 0 x 8 x 8 x 8 Blower motor output - hp / / / / Filters Size of filter - in. 0 x 0 x 0 x 0 x 0 x 0 x 0 x 0 x Shipping Data - package - lbs ELECTRICAL DATA Voltage - phase - 60hz 08/0V-ph 08/0V-ph 08/0V-ph 08/0V-ph Voltage - phase - 60hz V-ph overcurrent protection (unit only) - All voltages circuit ampacity (unit only) - 08/0V Blower Motor Full Load Amps - 08/0V.... circuit ampacity (unit only) - 60V Blower Motor Full Load Amps - 60V OPTIONAL ACCESSORIES - ORDER SEPARATELY ComfortSense 700 Thermostat H H H H Remote Outdoor Temperature Sensor (for ComfortSense 700) X68 X68 X68 X68 Dehumidification Relay Kit 6W6 6W6 6W6 6W6 Downflow Combustible Flooring Base K K K K Downflow Conversion Kit 8M7 8M7 8M7 8M7 Electric Heat - See Electric Heat Data tables. to 0 kw Electric Heat Breaker Cover Kit 8W0 8W0 8W0 8W0 Healthy Climate Germicidal Light UVC-V (V) X9 X9 X9 X9 Shielding Baffle (required) Y0 Y0 Y0 Y0 UVC-W-S (0/0v- ph) X9 X9 X9 X9 Shielding Baffle (required) X9900 X9900 X9900 X9900 Horizontal Support Frame Kit 6J8 6J8 6J8 6J8 Side Return Unit Stand (Upflow Only) K K K K Single Point Power Source Control Box H9 H9 H9 H9 Wall Hanging Bracket Kit (Upflow Only) K0 K0 K0 K0 High Performance Economizer (Commercial Only) 0U 0U 0U 0U Disposable frame type filter. HACR type circuit breaker or fuse. Blower motor is 60V - phase. Optional electric heat is 60V - phase. CBA7UHE / Page 6

7 SPECIFICATIONS General Data Model Number CBA7UHE-0 CBA7UHE-08 CBA7UHE-060 Nominal tonnage. Connections Suction (vapor) line (o.d.) - in. sweat 7/8 7/8 7/8 Liquid line (o.d.) - in. sweat /8 /8 /8 Condensate - in. fpt () / () / () / Indoor Coil Net face area - ft Tube outside diameter - in. /8 /8 /8 Number of rows Fins per inch Blower Wheel nominal diameter x width - in. x 9 x 9 x 9 Blower motor output - hp Filters Size of filter - in. 0 x x 0 x x 0 x x Shipping Data - package lbs ELECTRICAL DATA Voltage - phase - 60hz 08/0V-ph 08/0V- ph 08/0V- ph Voltage - phase - 60hz V-ph 60V-ph overcurrent protection (unit only) - All voltages circuit ampacity (unit only) - 08/0V Blower Motor Full Load Amps - 08/0V circuit ampacity (unit only) - 60V Blower Motor Full Load Amps - 60V OPTIONAL ACCESSORIES - ORDER SEPARATELY ComfortSense 700 Thermostat H H H Remote Outdoor Temperature Sensor (for ComfortSense 700) X68 X68 X68 Dehumidification Relay Kit 6W6 6W6 6W6 Downflow Combustible Flooring Base K K K Downflow Conversion Kit 8M7 8M7 8M7 Electric Heat - See Electric Heat Data tables to kw Electric Heat Breaker Cover Kit 8W0 8W0 8W0 Healthy Climate Germicidal Light UVC-V (V) X9 X9 X9 Shielding Baffle (required) Y0 Y0 Y0 UVC-W-S (0/0v- ph) X9 X9 X9 Shielding Baffle (required) X9900 X9900 X9900 Horizontal Support Frame Kit 6J8 6J8 6J8 Side Return Unit Stand (Upflow Only) K K K Single Point Power Source Control Box H9 H9 H9 Wall Hanging Bracket Kit (Upflow Only) K0 K0 K0 High Performance Economizer (Commercial Only) 0U 0U 0U Disposable frame type filter. HACR type circuit breaker or fuse. Blower motor is 60V - phase. Optional electric heat is 60V - phase. CBA7UHE / Page 7

8 BLOWER DATA CBA7UHE-08 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume and Motor Watts Tap Tap Tap Tap Tap cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts N/A N/A N/A N/A CBA7UHE-0 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume and Motor Watts Tap Tap Tap Tap Tap cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts CBA7UHE-00 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume and Motor Watts Tap Tap Tap Tap Tap cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts CBA7UHE-06 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume and Motor Watts at 08V Tap Tap Tap Tap Tap cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts CBA7UHE / Page 8

9 BLOWER DATA CBA7UHE-0 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume and Motor Watts Tap Tap Tap Tap Tap cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts CBA7UHE-08 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume and Motor Watts Tap Tap Tap Tap Tap cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts CBA7UHE-060 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume and Motor Watts Tap Tap Tap Tap Tap cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts REPLACEMENT CIRCUIT BREAKERS Voltage Description Catalog No. Voltage Description Catalog No. amp, pole K 0 amp, pole 6W7 0 amp, pole 7K70 amp, pole K amp, pole 7K07 0 amp, pole K6 08/0V - Phase 08/0V - Phase 0 amp, pole 9K amp, pole 8M86 amp, pole 7K7 0 amp, pole K 0 amp, pole K 60 amp, pole K7 60 amp, pole 7K7 CBA7UHE / Page 9

10 ELECTRIC HEAT DATA - CBA7UHE-08 SINGLE PHASE Model Number No. of Stages Input Volts kw Btuh Blower Motor Full Load Amps. kw lbs. kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs. ECB9-. (L7) ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) A breaker ECB9-6 (L) ECB9-6CB (L9) 0A breaker ECB9-8 (L0) ECB9-8CB (L) 0A breaker ECB9-9CB (T79) 60A breaker ECB9-0 (T8) ECB9-0CB (T87) 60A breaker , , , , ,0. 0., , , , , , , , , , , , , , , , , , , , , , , NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBA7UHE / Page 0

11 ELECTRIC HEAT DATA - CBA7UHE-0 SINGLE PHASE Model Number No. of Stages Input Volts kw Btuh Blower Motor Full Load Amps kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs. ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) A breaker ECB9-6 (L) ECB9-6CB (L9) 0A breaker ECB9-8 (L0) ECB9-8CB (L) 0A breaker ECB9-9CB (T79) 60A breaker ECB9-0 (T8) ECB9-0CB (T87) 60A breaker ,0. 0., , , , , , , , , , , , , , , , , , , , , , , NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBA7UHE / Page

12 ELECTRIC HEAT DATA - CBA7UHE-00 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs.. kw 0 lbs. kw lbs. THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) A breaker ECB9-6 (L) ECB9-6CB (L9) 0A breaker ECB9-8 (L0) ECB9-8CB (L) 0A breaker ECB9-9CB (T79) 60A breaker ECB9-0 (T8) ECB9-0CB (T87) 60A breaker ECB9-.CB (T88) () 0A breaker & () A breaker ECB9-CB (T9) () A breaker & () 60A Breaker ECB9-8 (L6) ECB9-0 (L6) ECB9-CB (L6) () 0A breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBA7UHE / Page

13 ELECTRIC HEAT DATA - CBA7UHE-06 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) A breaker ECB9-6 (L) ECB9-6CB (L9) 0A breaker ECB9-8 (L0) ECB9-8CB (L) 0A breaker ECB9-9CB (T79) 60A breaker ECB9-0 (T8) ECB9-0CB (T87) 60A breaker ECB9-.CB (T88) () 0A breaker and () A breaker ECB9-CB (T9) () A breaker and () 60A Breaker ECB9-0CB (T9) () 60A breaker and () 60A Breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBA7UHE / Page

14 ELECTRIC HEAT DATA - CBA7UHE-06 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. Model Number ECB9-8 (L6) ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) () 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBA7UHE / Page

15 ELECTRIC HEAT DATA - CBA7UHE-0 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. No. Volts kw Model Number of Input Input Stages ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) A breaker ECB9-6 (L) ECB9-6CB (L9) 0A breaker ECB9-8 (L0) ECB9-8CB (L) 0A breaker ECB9-9CB (T79) 60A breaker ECB9-.CB (T88) () 0A breaker and () A breaker ECB9-CB (T9) () A breaker and () 60A breaker ECB9-0CB (T9) () 60A breaker and () 60A breaker ECB9-CB (L9) () 60A breaker and () A breakers Btuh Input Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBA7UHE / Page

16 ELECTRIC HEAT DATA - CBA7UHE-0 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBA7UHE / Page 6

17 ELECTRIC HEAT DATA - CBA7UHE-08 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) A breaker ECB9-6 (L) ECB9-6CB (L9) 0A breaker ECB9-8 (L0) ECB9-8CB (L) 0A breaker ECB9-9CB (T79) 60A breaker ECB9-.CB (T88) () 0A breaker & () A breaker ECB9-CB (T9) () A breaker & () 60A breaker ECB9-0CB (T9) () 60A breaker & () 60A breaker ECB9-CB (L9) () 60A breaker & () A breakers No. of Stages Input Blower Motor Full Load Amps NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Volts kw Btuh Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBA7UHE / Page 7

18 ELECTRIC HEAT DATA - CBA7UHE-08 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBA7UHE / Page 8

19 ELECTRIC HEAT DATA - CBA7UHE-060 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) A breaker ECB9-6 (L) ECB9-6CB (L9) 0A breaker ECB9-8 (L0) ECB9-8CB (L) 0A breaker ECB9-9CB (T79) 60A breaker ECB9-.CB (T88) () 0A breaker & () A breaker No. of Stages Input Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , kw lbs. ECB9-CB (T9) () A breaker & () 60A breaker 08. 8, , , , kw 9 lbs. ECB9-0CB (T9) () 60A breaker & () 60A breaker 08.0, , , kw ECB9-CB (L9) 9 lbs. () 60A breaker & () A breakers NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBA7UHE / Page 9

20 ELECTRIC HEAT DATA - CBA7UHE-060 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBA7UHE / Page 0

21 DIMENSIONS - INCHES (MM) UPFLOW POSITION / (9) / (9) -/6 (8) D LINE VOLTAGE INLETS (Top and Left Side) TOP VIEW B SUPPLY AIR OPENING / (9) LOW VOLTAGE INLETS (Top and Right Side) /8 (6) -/8 (9) SUCTION LINE () -/8 (7) LIQUID LINE C -/ (70) DETAIL OF PIPING PLATE -/ () -/8 () -/ (89) CONDENSATE DRAINS () (Horizontal) CONDENSATE DRAINS () (Upflow and Downflow) AIR FLOW G OPTIONAL ELECTRIC HEAT (Field Installed) BLOWER Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. A PIPING PLATE H SUCTION LINE COIL LIQUID LINE /8 (6) Return Air F FRONT VIEW /8 (6) FILTER ACCESS FILTER () Return Air E SIDE VIEW /8 (6) Model No. A B C D E F G H CBA7UHE-08 CBA7UHE-0 CBA7UHE-00 CBA7UHE-06 CBA7UHE-0 CBA7UHE-08 CBA7UHE-060 in. 9-/ -/ 0-/8 9-/ 9 0 -/8 -/8 mm in. -/ -/8 9-/ 0 6-/8 -/8 mm in. 8-/ -/ -/8 9-/ 0 7-7/8 0-/8 mm in. 6-/ -/ -/8 9-/ 0 7-7/8 -/8 mm CBA7UHE / Page

22 DIMENSIONS - INCHES (MM) DOWNFLOW POSITION with Optional Downflow Conversion Kit (Required) DETAIL OF PIPING PLATE /8 (6) E /8 (6) F RETURN AIR OPENING /8 (6) -/8 (9) SUCTION LINE () /8 (9) LIQUID LINE -/8 () CONDENSATE DRAINS () (Horizontal) CONDENSATE DRAINS () (Upflow and Downflow) () TOP VIEW () -/ () -/ (89) B FILTER ACCESS C FILTER H PIPING PLATE SUCTION LINE COIL LIQUID LINE AIR FLOW G A OPTIONAL ELECTRIC HEAT (Field Installed) LOW VOLTAGE (Right Side) LINE VOLTAGE (Left Side) BLOWER / (9) Supply Air D FRONT VIEW / (9) /8 (6) Supply Air -/6 (8) SIDE VIEW /8 (6) Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. Model No. A B C D E F G H CBA7UHE-08 CBA7UHE-0 CBA7UHE-00 CBA7UHE-06 CBA7UHE-0 CBA7UHE-08 CBA7UHE-060 in. 9-/ -/ 0-/8 9-/ 9 0 -/8 -/8 mm in. -/ -/8 9-/ 0 6-/8 -/8 mm in. 8-/ -/ -/8 9-/ 0 7-7/8 0-/8 mm in. 6-/ -/ -/8 9-/ 0 7-7/8 -/8 mm CBA7UHE / Page

23 DIMENSIONS - INCHES (MM) DETAIL OF PIPING PLATE RIGHT-HAND AIR DISCHARGE -/8 (7) () LIQUID LINE FILTER SUCTION LINE -/ (6) CONDENSATE DRAINS () (Upflow and Downflow) /8 (6) -/ () -/ (8) -/8 (9) -/8 () CONDENSATE DRAINS () (Horizontal) LIQUID LINE COIL SUCTION LINE H TOP VIEW A BLOWER OPTIONAL ELECTRIC HEAT (Field Installed) G C Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. /8 (6) LINE VOLTAGE INLETS (Top and Right Side) -/6 (8) / (9) / (9) E /8 (6) F RETURN AIR OPENING () PIPING PLATE AIR FLOW B SUPPLY AIR OPENING D /8 (6) END VIEW FILTER ACCESS FRONT VIEW LOW VOLTAGE INLETS (Bottom and Right Side) END VIEW / (9) LEFT-HAND AIR DISCHARGE FILTER DETAIL OF PIPING PLATE C BLOWER COIL -/8 () Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. OPTIONAL ELECTRIC HEAT (Field Installed) TOP VIEW SUCTION LINE LIQUID LINE -/8 (9) SUCTION LINE LIQUID LINE () -/8 (7) / (9) / (9) -/6 (8) LOW VOLTAGE INLETS (Top and Left Side) /8 (6) G A H /8 (6) D SUPPLY AIR OPENING B AIR FLOW PIPING PLATE FILTER ACCESS CONDENSATE DRAINS () (Horizontal) () E RETURN AIR OPENING F /8 (6) / (9) END VIEW LINE VOLTAGE INLETS (Bottom and Left Side) FRONT VIEW -/ () -/ (6) -/ (8) /8 (6) END VIEW Model No. CBA7UHE-08 CBA7UHE-0 CBA7UHE-00 CBA7UHE-06 CBA7UHE-0 CBA7UHE-08 A B C D E F G H inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm 9-/ -/ 0 0-/8 9-/ /8 6 -/ / 0 -/8 7 9-/ / /8 6 8-/ 86 -/ 0 -/8 6 9-/ / /8 778 CBA7UHE / 88 -/ 0 -/8 6 9-/ / /8 879 CBA7UHE / Page

24 DIMENSIONS - INCHES (MM) AIR FLOW PIPING PLATE AIR FLOW B B AIR FLOW PIPING PLATE A /8 (6) RIGHT-HAND AIR FLOW B /8 (6) /8 (6) A LEFT-HAND AIR FLOW B AIR FLOW PIPING PLATE A Model No. CBA7UHE-08 CBA7UHE-0 CBA7UHE-00 CBA7UHE-06 CBA7UHE-0 CBA7UHE-08 A B in. mm in. mm 9-/ -/ 0 9 -/ 0 8-/ 86 -/ 0 CBA7UHE / 88 -/ 0 PIPING PLATE AIR FLOW A UPFLOW DOWNFLOW /8 (6) SIDE RETURN UNIT STAND (Upflow Only) 6 (06) 6 () -/ (0) ADJUSTABLE 0 (08) to (6) ALL UNITS CBA7UHE / Page

25 DIMENSIONS - INCHES (MM) DOWNFLOW COMBUSTIBLE FLOORING BASE AIR HANDLER DOWNFLOW COMBUSTIBLE FLOORING BASE Catalog No. K -/8 () -/8 () 0 (08) TOP VIEW -/8 (89) / (9) Break off extended width at pre-perforated line to fit specific air handler application. NOTE - Width of base includes an additional in. ( mm) for air handler positioning adjustment. -/8 () SUPPLY AIR OPENING /8 (6) -/ () Opening SIDE VIEW (76) A B C Model No. 08, 0 00, 06 0, 08, 060 in. mm in. mm in. mm A -/ B / C /8 676 CBA7UHE / Page

26

27

28 REVISIONS Sections Electric Heat Data Description of Change Updated circuit breaker type and usage for most single phase ECB9 models to reduce number of circuit breaker field replacements. Visit us at For the latest technical information, Contact us at LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 07 Lennox Industries, Inc.

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CXM ELITE SERIES R-0A Ready - Multi-Position ulletin No. 0 March 0 Supersedes February 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMER IDENTIFICATION

More information

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants BCS PRODUCT SPECIFICATIONS Suitable for use with R- and R-0A refrigerants.5 to 5 Tons Upflow and Horizontal (Counterflow with optional kit) Pre-painted cabinets with foil faced insulation Electrical connections

More information

EDM4X, EDM2X. Product Specifications EXPANSION VALVE COILS ALL MODELS

EDM4X, EDM2X. Product Specifications EXPANSION VALVE COILS ALL MODELS EDM4X, EDM2X Product Specifications EXPANSION VALVE COILS ALL MODELS 1 1/2 thru 5 Tons Multiposition installation upflow, downflow, or horizontal Available for R 410A or R 22 Bolt on TXV metering device

More information

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR037-150, ZF078-150 JOB NAME: PURCHASER: LOCATION: ORDER NO: ENGINEER: SUBMITTED TO:

More information

SUBMITTAL DATA SHEET COOLING PERFORMANCE HEATING PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE ELECTRICAL DATA TOTAL UNIT WEIGHT

SUBMITTAL DATA SHEET COOLING PERFORMANCE HEATING PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE ELECTRICAL DATA TOTAL UNIT WEIGHT SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: DM/DF/DH078-120, DJ150, DR090-150, ZH/ZJ037-150, ZF/ZR078-150 JOB NAME: PURCHASER: LOCATION:

More information

VFR Parallel Flow, Fan-Powered, VAV Terminals

VFR Parallel Flow, Fan-Powered, VAV Terminals VFR Parallel Flow, Fan-Powered, VAV Terminals Model VFR construction features Galvanized-steel casing withstands 125-hour, salt-spray test per ASTM B-117 All unit configurations listed with ETL for safety

More information

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP078-150 JOB NAME: PURCHASER: LOCATION: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED

More information

MODEL CFD Forward Curved Belt Driven Inline Duct Blower

MODEL CFD Forward Curved Belt Driven Inline Duct Blower Forward Curved Belt Driven Inline Duct Blower Model Overview S&P s Forward Curved Belt Driven Inline Duct Blowers are designed for supply, exhaust or ducted return applications. The CFD is an economical

More information

EVAPORATOR COILS Product Specifications

EVAPORATOR COILS Product Specifications EVAPORATOR COILS Product Specifications All piston coils are compatible with R22 or R410A All drain pans are compatible with UV lights Form No. EC/M/U/H1P-100 (03/2014) EC1P/EM1P - CASED Upflow/Counterflow

More information

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL S BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 8,648 CFM in high static pressure applications up to 2-3/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance

More information

Toyostove Error Code EE 2 (EE 6)

Toyostove Error Code EE 2 (EE 6) Toyostove Error Code EE 2 (EE 6) WARNING Rural Energy Enterprises, Inc. does not accept liability for the improper use of this information. Installation, service, and maintenance of heating equipment should

More information

Installation Instructions for. Thrifty King CT Series Fountains

Installation Instructions for. Thrifty King CT Series Fountains Installation Instructions for Thrifty King CT Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when

More information

Job Name: Tag# 4 Port, 3-Ton Outdoor Heat Pump

Job Name: Tag# 4 Port, 3-Ton Outdoor Heat Pump Job Name: Tag# Submittal Data Sheet 4 Port, 3-Ton Outdoor Heat Pump 4MXS36NMVJU Efficiency SEER EER HSPF COP Non-Ducted 17.7 9.2 12.2 3.89 Ducted 14 7.9 8.2 4.47 Mixed 15.85 8.55 10.2 4.18 Performance

More information

DP13GM DP15GM. Multi-position Installation. Comfort for Life

DP13GM DP15GM. Multi-position Installation. Comfort for Life DP13GM DP15GM Packaged GAS/Electric Units Energy-Efficient, SCroll Compressor Multi-position Installation Comfort for Life www.daikincomfort.com "I'm a Daikin Comfort Pro" Those five simple words can offer

More information

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 8,098 CFM in high static pressure applications up to 1-3/4 w.g. Attractive spun

More information

PBG PACKAGED GAS BURNERS

PBG PACKAGED GAS BURNERS CAPACITIES PBG PACKAGED GAS BURNERS Air Static Pressure ("wc) Excess Air (%) Flame Length (Inches) Model No. Capacity (1000 Btu/hr) Motor HP Air Flow (SCFH) Gas Flow (SCFH) Gas Turndown Max. 440 5.9 4560

More information

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES BELT DIVE CENTIFUGAL DOWNBLAST OOF EXHAUSTES - BELT DIVE CENTIFUGAL OOF EXHAUSTE MODEL FEATUES Exhaust air up to 31,563 CFM in high static pressure applications up to 1-3/4 w.g. Attractive spun aluminum

More information

Gas Conversion Kits and Instructions

Gas Conversion Kits and Instructions Gas Conversion Kits and Instructions INSTALLATION FORM RGM 432/433-GC (Version D.1) Obsoletes Form RGM 432/433-GC (Version D) APPLIES TO: Model FT and Model SFT All gas conversion must be done by a qualified

More information

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the

More information

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING INSTRUCTION MANUAL for ALEKO RETRACTABLE AWNING www.alekoproducts.com FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY! 1 Important Safety Precautions WARNING NOTE: FOR PERSONAL SAFETY,

More information

Blue Series Hot Melt Hose with RediFlext II Hanger System

Blue Series Hot Melt Hose with RediFlext II Hanger System Instruction Sheet P/N 1124594_01 Blue Series Hot Melt Hose with RediFlext II Hanger System Safety WARNING! Allow only personnel with appropriate training and experience to operate or service the equipment.

More information

Installation Instructions for. Thrifty King CT Series Fountains

Installation Instructions for. Thrifty King CT Series Fountains Installation Instructions for Thrifty King CT Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when

More information

PARTS MANUAL Gas Furnace F9MVT, G9MVT

PARTS MANUAL Gas Furnace F9MVT, G9MVT Gas Furnace F9MVT, G9MVT Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal

More information

Emergency Stop Devices

Emergency Stop Devices New! Selection and Application of.. 278 Emergency Stop Rope Pull Switches........... 279 New! Emergency Stop Push Buttons............... 293 Banner Engineering Corp. Minneapolis, MN U.S.A. bannerengineering.com

More information

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

Instructions for Converting Range to Operate on Liquefied Petroleum Gas INSTALLATION AND SERVICES MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT: SAVE INSTRUCTION MANUAL FOR THE LOCAL INSPECTOR S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE This conversion

More information

PARTS LIST CHARGER 2022 ABLT

PARTS LIST CHARGER 2022 ABLT PARTS LIST CHARGER 2022 ABLT HEAD ASSEMBLY ITEM PART NO. DESCRIPTION QTY 101 5990731 SPRING CLIP PAD HOLDER SET INCLUDES: 1 101A 9120205 #8 X 1/2 PAN HEAD PHILLIPS SHEET METAL SCREW PACK OF 3 3 102 9121490

More information

PARTS MANUAL Gas Furnace F9MXT, G9MXT

PARTS MANUAL Gas Furnace F9MXT, G9MXT Gas Furnace F9MXT, G9MXT Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal

More information

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001 QUALITY MANAGEMENT SYSTEM CERTIFIED HEALTH & SAFETY MANAGEMENT SYSTEM Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING ISO 9001:2008 REGISTERED COMPANY EN ISO 10380 PRODUCED AND TESTED OHSAS 18001

More information

Electronic Temperature Controls

Electronic Temperature Controls ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple

More information

Frequently Asked Questions

Frequently Asked Questions Customer Service (888) 961-7727 ahsservice@watkinsmfg.com Frequently Asked Questions What makes Lifesmart Spas different from other spas? Lifesmart spas are rotationally molded. This manufacturing technique

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS C24DA/GA-SERIES STEAMERS C24GA6 C24GA10 C24DA6 C24DA10 ML-138085 ML-138088 ML-152022 ML-152023 VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC 3600 NORTH POINT BLVD.,

More information

Saw Blade Lube Systems

Saw Blade Lube Systems Environmentally Friendly Lubrication Saw Blade Lube Systems Cutting Edge Technology Saw Blade Lube Systems Cutting Edge Technology Cutting Edge Technology Unist saw blade lubrication systems deliver all

More information

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code. 29-10-2013 CAUTION Before resetting your electronic card that displays an error code. Error Code H Service the stove COMPLETELY as described in this manual. Check the chimney pipe. Error Code O Service

More information

Nexus Standard Glove Box System

Nexus Standard Glove Box System NOW CONFORMS TO UL AND CSA STANDARDS FOR LABORATORY EQUIPMENT Nexus Standard Glove Box System Vacuum Atmospheres Company Vacuum Atmospheres Company 4652 W. Rosecrans Ave. East Coast Office P.O. Box 1043

More information

Section 11 Workstation Components

Section 11 Workstation Components 1 Section Quick and easy access to parts is made possible by the wide variety of trays, bins, and framing components available from Bosch. Individual workstation grab trays, containers, and ledges place

More information

CADDY CORPORATION. Hot Food Caddys

CADDY CORPORATION. Hot Food Caddys Food Service Equipment Air Systems page of 7 Open or Heated / Regular or Slimline REGULAR STRAIGHT FULL CONVENIENCE SLIMLINE STRAIGHT SLIMLINE L-SHAPED (TF-604 & TF-624 Shown) (TF-66 & TF-66 Shown) (TF-64

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL DB MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G) Part B, ection Model Voltage This section covers the following unit configurations. 3400V All Pump Piston Pump (E or G) Manifold Control 4-Port (A) Vista tandard (V) Vista Pattern (PC) Vista Temperature

More information

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations Installation Instructions For Model Series G Furnaces, P(G,N) Gas/Electric Appliances, and R Gas/Electric Appliances

More information

Eclipse Hermetic Gas Boosters Series HB

Eclipse Hermetic Gas Boosters Series HB Datasheet 620 7/6/2012 Eclipse Hermetic Gas Boosters Series HB Version 1.1 Type Designations The booster is identified by catalog model, assembly number, and ordering part number. The catalog model number

More information

PROPANE & HIGH ALTITUDE CONVERSION INSTRUCTIONS

PROPANE & HIGH ALTITUDE CONVERSION INSTRUCTIONS Form CP-VC/VP-GC (Version D) Obsoletes Form CP-VC/VP-GC (Version C) PROPANE & HIGH ALTITUDE CONVERSION INSTRUCTIONS (FOR ALTITUDES OF 0-10,000 ft ONLY) Applies to: Gas-Fired, Tubular Radiant, w-intensity

More information

INSTALLATION GUIDE INTRODUCTION

INSTALLATION GUIDE INTRODUCTION INSTALLATION GUIDE for for HotEdge Rail Rail INTRODUCTION HotEdge Rail is a patent pending one-piece roof edge ice melt systems engineered to easily install on standing seam, pro panel, and corrugated

More information

Mathey Dearman's revolutionary MagnaCut XM enables

Mathey Dearman's revolutionary MagnaCut XM enables Pipe and Plate Cutter & Welder (PATENTED) Mathey Dearman's revolutionary enables the welder and pipefitter to cut, bevel, and even weld steel pipe and steel plate without having to secure the machine to

More information

Modular Cut-Wrap Facility - Retail Market

Modular Cut-Wrap Facility - Retail Market Modular Cut-Wrap Facility - Retail Market For further processing of multi-species carcasses from Mobile Meat Processing Units (MMPU) Carcass Aging and Holding Cooler Mobile Reefer Units Adapted for specific

More information

Big SHOT III Hybridization Oven

Big SHOT III Hybridization Oven Big SHOT III Hybridization Oven Models 230402 and 230402-2 Whether you are working with Northern Blots, Southern Blots, Microarrays or another application that requires incubation, you will find the Big

More information

UNODOS + / FLOCDOS +

UNODOS + / FLOCDOS + Operation manual UNODOS+ / FLOCDOS+ (01-09) page 1 of 7 UNODOS + / FLOCDOS + Table of contents page 1. Technical description... 2 1.1 The function... 2 1.2 Technical details... 2 1.3 The dosing performance...

More information

MOTORIZED OR MANUAL LATERAL ARM BOX AWNING. Product Overview... 1 Component Checklist... 2

MOTORIZED OR MANUAL LATERAL ARM BOX AWNING. Product Overview... 1 Component Checklist... 2 INSTALLATION MANUAL FREEDOM AWNING RV MOTORIZED OR MANUAL LATERAL ARM BOX AWNING TABLE OF CONTENTS Product Overview... 1 Component Checklist... 2 Installation... 3 Attaching the Mounting Plates... 3 Mounting

More information

Installation instruction

Installation instruction Installation instruction Ci51 116 FACTS Technical specifications Model i51 Log box (option) Output 6-11 kw Nominal output 8 kw Efficiency 80 % Weight (kg) 215 50 Powerstone (option): + 100 kg Width (mm)

More information

Mitchell. Furniture Systems

Mitchell. Furniture Systems Mitchell Furniture Systems Withstand the Test of Time Many of our tables are still in use after 40 years. They last that long because we simply build them better. More Steel Our tables have a solid feel

More information

The safe & affordable install

The safe & affordable install QSLG1000 Quick-Sling SPECS QSLG1000 Each arm attaches to wood using 2 zip screws for stability & a 4 through bolt & wing nut for security. Installs to steel using steel beam adapters. 28 points of anti-vibration

More information

FILTERED FAN PACKAGES

FILTERED FAN PACKAGES FILTERED FAN PACKAGES PLASTIC & METAL FILTERED FANS EFFICIENT, QUITE BALL BEARING MOTORS NEMA TYPE 1 AND 3R ALL KITS INCLUDE GASKETS, HARDWARE, AND TEMPLATE UL LISTED Plastic FILTER FAN PACKAGES Injection

More information

The four elements of nature: Fire, Water Earth & Air

The four elements of nature: Fire, Water Earth & Air Why our flame is so natural... Our range of balanced flue gas stoves gives a beautiful lazy dancing flame pattern which emulates that of a traditional wood burning stove and with the added features of

More information

Crusader Training updated 11/1/16

Crusader Training updated 11/1/16 Crusader Training updated 11/1/16 High Gloss Exterior Whether your customer takes the time to wax their camper, or not, the high gloss gel coat is going to look great for years to come Crusader is equipped

More information

for for HotValley TM TM

for for HotValley TM TM for for HotValley INTRODUCTION The HotValley system holds self-regulating ice melt cable in place on roof valleys and flashings. It can be used in roof valleys (see above), on flashings next to vertical

More information

COLD ROOM DOORS. catalog

COLD ROOM DOORS. catalog log COLD ROOM DOORS catalog 2017-2018 about Quality coldroom doors designed for efficiency Igloodoors is the flagship product line of Coldroombuilder, a high-end product manufacturer for coldroom systems

More information

PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS

PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS The information contained in this manual is advisory and in general terms only and does not constitute

More information

WARNING Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no obstructions around or underneath the oven.

WARNING Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no obstructions around or underneath the oven. SECTION 2 SECTION 2 WARNING Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no obstructions around or underneath the oven. CAUTION For additional installation

More information

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description .1 PSG Series Contents Description PSG Series Catalog Number Selection................ Technical Data and Specifications.......... Power Derating Curves.................. Dimensions...........................

More information

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the

More information

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the

More information

Cold Water Rheology Kit

Cold Water Rheology Kit Cold Water Rheology Kit Instruction Manual Manual No. 372144, Revision E Instrument No. 207952 or 207953 Fann Instrument Company Cold Water Rheology Kit Instruction Manual 2012 Fann Instrument Company

More information

300 ft. 5/8 Hose wagon

300 ft. 5/8 Hose wagon 300 ft. 5/8 Hose wagon Model 95956 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. (Garden hose is not included).

More information

Safety Interlock Switches

Safety Interlock Switches r Safety Interlock Switches TL19 TL19 Safety Interlock Switch with uard Door Locking High locking force of 10 N (270 lb.) locks guard door shut until machine is safe to enter IP67 (NEMA 6) enclosure enables

More information

The Most Efficient. Air Distribution. System! Air Management Products Catalog

The Most Efficient. Air Distribution. System! Air Management Products Catalog The Most Efficient Air Distribution System! Air Management Products Catalog Return Air Drop Packages (Kits) Includes Top Collar, 2 sections of Duct and Return Air Boot in one Package Model Numbers No.

More information

Cross Folder AF-76 series. AF-76 series. Cross Folder AF-764AKLL/764AKL/762KLL/762KL. Accurate Cross Folding with Easy Operation

Cross Folder AF-76 series. AF-76 series. Cross Folder AF-764AKLL/764AKL/762KLL/762KL. Accurate Cross Folding with Easy Operation Cross Folder AF-76 series AF-76 series Cross Folder AF-764AKLL/764AKL/762KLL/762KL Accurate Cross Folding with Easy Operation 8-page, 16-page, and 32-page cross folding The AF-76 series folders are specially

More information

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V TITAN pt. no.: 02 0000 0128 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended

More information

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

Instructions for Converting Range to Operate on Liquefied Petroleum Gas INSTALLATION AND SERVICES MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT: SAVE INSTRUCTION MANUAL FOR THE LOCAL INSPECTOR S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE This conversion

More information

SPEDESTER Series QUICK REFERENCE GUIDE

SPEDESTER Series QUICK REFERENCE GUIDE Spedester series Digital DC Drives come with an extensive range of standard software blocks, it can take control of the most demanding motion control tasks. Designed for industrial applications, Spedester

More information

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web:  - SVL Essential DIN Rail Series SVL Series power supplies are perfect for high volume, controlled environment applications where essential features are the only requirement. When space inside an enclosure

More information

Model. Oasis Automatic and Manual RV Door Awning System INSTALLATION & OPERATING INSTRUCTIONS

Model. Oasis Automatic and Manual RV Door Awning System INSTALLATION & OPERATING INSTRUCTIONS Oasis Automatic and Manual RV Door Awning System USA SERVICE OFFICE Dometic Corp. 509 So. Poplar St. LaGrange, IN 46761 260-463-4858 CANADA Dometic Dist. 866 Langs Dr. Cambridge, Ontario CANADA N3H 2N7

More information

STRAIGHT BLADE RECEPTACLES

STRAIGHT BLADE RECEPTACLES STRAIHT BLADE RECEPTACLES ENERLITES INC. offers a full line of 15 A, 20 A, 30 A and 50 A Receptacles available in Residential rade, Commercial rade, and Industrial rade. ENERLITES Receptacles are precision-manufactured

More information

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories) MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system

More information

Product Cut Sheet Z4-SERIES SEISMICFRAME CABINET SYSTEM SERVICE PARTS

Product Cut Sheet Z4-SERIES SEISMICFRAME CABINET SYSTEM SERVICE PARTS Service Parts This document lists service parts for the Z4 SeismicFrame Cabinet System. Service parts include mounting rails, top panel, side panels, doors and door lock kits and are used as replacement

More information

ALEKO Victoria Series Retractable Awning Instructions for Installation and Operation

ALEKO Victoria Series Retractable Awning Instructions for Installation and Operation www.alekoproducts.com ALEKO Victoria Series Retractable Awning Instructions for Installation and Operation PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE! The owner s manual includes assembly and operating

More information

PRODUCT MANUAL - M096

PRODUCT MANUAL - M096 PRODUCT MANUAL - M096 MODEL 270 ELECTRIC CAN OPENER 1 I. LABELS L087--CAUTION 2 II. SPECIFICATIONS MODEL NO. 270 POWER 115 VOLT, 1.5 AMP, 50-60HZ REQUIREMENTS 230 VOLT, 0.8 AMP, 50-60 HZ NORMAL SPEED 200-250

More information

WASHGUARD. More Than Just a Motor Company WASHDOWN DUTY PT PRODUCTS ELECTRIC MOTORS, GEAR REDUCERS, AC & DC DRIVES. Bulletin 1500

WASHGUARD. More Than Just a Motor Company WASHDOWN DUTY PT PRODUCTS ELECTRIC MOTORS, GEAR REDUCERS, AC & DC DRIVES. Bulletin 1500 A REGAL-BELOIT COMPANY More Than Just a Motor Company WASHGUARD WASHDOWN DUTY PT PRODUCTS ELECTRIC MOTORS, GEAR REDUCERS, AC & DC DRIVES Bulletin 1500 WASHGUARD WHITE EPOXY Enhanced Performance in Wet,

More information

Installation Instructions

Installation Instructions Installation Instructions C 710 www.contura.eu 50 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. C710-CPR-160329-SE-1 PRODUCT Product type Stove lit with solid biofuels

More information

Conservatory awning W8 Description

Conservatory awning W8 Description 1 3 4 Application Large-area external sun shading system for shading glazed conservatories, patio roofs and pergolas with flat pitch roofs. Function principle: tensioning system via toothed belt with steel

More information

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

Single, oversized roller compresses a low friction hose through a full 360-degree rotation Graco EP Series Hose Pump Technology Single, oversized roller compresses a low friction hose through a full 360-degree rotation More flow per revolution than conventional designs One hose compression per

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-5480 www.cmafh.com Safety Interlock Switches TL19 Safety Interlock Switch with uard Door Locking High

More information

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information FBO-0 and FBO-4 Fuel Filter/Water Separator For High-Flow Applications These versatile housings have three filter options to meet various requirements: a fuel filter/water separator, a silicone treated

More information

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW MODEL CM OVERVIEW The CM Series belt driven backward inclined Utility Vent Set fans from S&P offer an excellent choice of product for all medium and high pressure exhaust or supply applications for commercial,

More information

DRAWER SYSTEMS HEAVY-DUTY STEEL & ALUMINUM Heavy-Duty Steel Drawer System. Heavy-Duty Aluminum Drawer System

DRAWER SYSTEMS HEAVY-DUTY STEEL & ALUMINUM Heavy-Duty Steel Drawer System. Heavy-Duty Aluminum Drawer System HEAVY-DUTY STEEL & ALUMINUM DRAWER SYSTEMS Heavy-Duty Steel Drawer System 500 lb. Rated Slides - Drawer slides are rated to hold up to the rigors of heavy-duty use and will support heavy tools and other

More information

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

LOCAL DISCONNECT SWITCHES Manual Motor Controllers LOCAL DISCONNECT SWITCHES Manual Motor Controllers 1 2 Ensto Manufacturer of electrical components and systems This brochure presents the economical, versatile and reliable Ensto Origin manual motor controllers

More information

HEATER POWER CONTROLLER

HEATER POWER CONTROLLER HEATER POWER CONTROLLER /04 Rev 0 - - ii PROCON MODEL HPC TABLE OF CONTENTS DESCRIPTION... MANUAL REVISIONS... 5 WARRANTY... 5 SPECIFICATIONS... 6 DRAWINGS PHYSICAL DIMENSIONS 44-090095-0-00... 7 PANEL

More information

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the

More information

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post Introduction: ComplianceSigns.com offers a variety of sign posts, sign mounting hardware, sign bases, mounting tape and more to mount your safety signs indoors or out. We offer three styles of sign posts,

More information

Set-It & Forget-It. save labor, save time. Applications include:

Set-It & Forget-It. save labor, save time. Applications include: Set-It & Forget-It save labor, save time ZERO tumble blast cabinets deliver efficient, affordable batch processing to clean, peen, deburr, or finish parts. Applications include: Remove residual sand from

More information

OW LEE CASUAL FIRESIDE Q&A

OW LEE CASUAL FIRESIDE Q&A Are the fire pits certified? All of our units are lab tested and certified by Labtest Certification, we are ANSI and CSA approved for the United States and Canada. The Casual Fireside Fire Pits BTU rated?

More information

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS For your safety: If you smell gas: 1. Shut off gas to the appliance 2. Extinguish

More information

ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O

ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 Spec 144 11/4/03 AH-O, Front View Data 144-1 AH-O, Back View Data 144-1 TAH-O, Front View Data 144-2

More information

TRUSTED SOLUTIONS AND INNOVATION PINS & BUSHINGS INCH

TRUSTED SOLUTIONS AND INNOVATION PINS & BUSHINGS INCH www.danly.com TRUSTED SOLUTIONS AND INNOVATION PINS & BUSHINGS INCH www.danly.com PINS & BUSHINGS INCH Service We Deliver and Quality You Can Depend On DANLY IEM is a leading manufacturer of die sets and

More information

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary voltage drops up to 0% of rated voltage. Wide-range AC-activated

More information

MODELS: 440 SM & 440 SMSS

MODELS: 440 SM & 440 SMSS Most Dependable Fountains, Inc. OPERATIONS MANUAL MODELS: 440 SM & 440 SMSS Most Dependable Fountains, Inc 5705 Commander Drive Arlington, TN 38002 800-552-6331 FOUNTAINS, MOST DEPENDABLE FOUNTAINS, INC.

More information

COMMERCIAL GRILLE DOORS

COMMERCIAL GRILLE DOORS Model ECONO-GRILLE Standard Alpine Brick Pattern Commercial Rolling Grille Door NOTE: For specifications, architects must choose from a variety of options. The standard choice will be shown first in plain

More information

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution sdmat_048_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Installation Instructions

Installation Instructions Installation Instructions C810 www.contura.eu 50 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. C810-CPR-130610-SE-1 PRODUCT Product type Stove lit with solid biofuels

More information

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination. SIDERMAT combination 630 to 1800 A sdmat_048_a_1_cat SIDERMAT combination are manually operated tri- or tetrapolar fuse disconnecting switches which can be triggered remotely. They provide breaking and

More information

Daikin Fire Rated Hoses & Hose Kits for Water Source Heat Pumps. Catalog People and ideas you can trust.

Daikin Fire Rated Hoses & Hose Kits for Water Source Heat Pumps. Catalog People and ideas you can trust. Daikin Fire Rated Hoses & Hose Kits for Water Source Heat Pumps Catalog 1196-8 People and ideas you can trust. Contents General Information... 4 Daikin Water Source Heat Pump Hoses & Hose Kits 4 Summary

More information

General Purpose High Power PCB Relays

General Purpose High Power PCB Relays T9 Series Two-pole 3A PCB or Panel Mount Relay n A, form A (NO) and form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, LRA / 5.3FLA n Meets requirements of UL 58 and UL

More information