INSTRUCTIONS FOR USE (IFU)

Size: px
Start display at page:

Download "INSTRUCTIONS FOR USE (IFU)"

Transcription

1 ! INSTRUCTIONS FOR USE (IFU) ME1000 BROACH ADAPTERS Dual Offset Left Broach Adapter Straight Broach Adapter Dual Offset Right Broach Adapter Rx ONLY English (EN) TABLE OF CONTENTS! 1 English

2 INTRODUCTION... 2 GENERAL PRODUCT INFORMATION... 4 HOW SUPPLIED... 4 DEVICE DESCRIPTION... 4 INTENDED USE... 4 CONTRAINDICATIONS, WARNINGS, PRECAUTIONS... 5 SYMBOLS GLOSSARY... 6 SIGNAL WORDS... 6 GENERAL SAFETY INFORMATION... 9 PRODUCT FEATURES AND SPECIFICATIONS ENVIRONMENTAL CONDITIONS OPERATING INSTRUCTIONS SAFETY INSTRUCTIONS BROACH ATTACHMENT & REMOVAL CLEANING SAFETY INSTRUCTIONS POINT OF USE INSTRUCTIONS CONTAINMENT INSTRUCTIONS PREPARATION FOR CLEANING INSTRUCTIONS MANUAL CLEANING INSTRUCTIONS LUBRICATION SAFETY INSTRUCTIONS LUBRICATION INSTRUCTIONS INSPECTION AND FUNCTIONAL TESTING SAFETY INSTRUCTIONS INSPECTION INSTRUCTIONS FUNCTIONAL TESTING INSTRUCTIONS PACKAGING SAFETY INSTRUCTIONS PACKAGING METHODS PACKAGING INSTRUCTIONS STERILIZATION SAFETY INSTRUCTIONS STERILIZATION INSTRUCTIONS STORAGE AND HANDLING SAFETY INSTRUCTIONS STORAGE INSTRUCTIONS TROUBLESHOOTING MAINTENANCE AND REPAIR DISPOSAL AND RECYCLING ORDERING INFORMATION INTRODUCTION These Instructions for Use is recommended for safe, effective and compliant operation, processing and care for the ME1000 Broach Adapters.! 2 English

3 These Instructions for Use is intended for in-service trainers, biomedical equipment technicians, and central supply/sterile processing technicians. Keep and consult these Instructions for Use during the life of the product. NOTES: Medical Enterprises Distribution is referred to as MED in these Instructions for Use. The ME1000 Surgical Impactor and its accessories are referred to as the ME1000 Impact System in these Instructions for Use.! 3 English

4 GENERAL PRODUCT INFORMATION HOW SUPPLIED The ME1000 Broach Adapters are provided non-sterile. The Broach Adapters must be cleaned, lubricated, inspected, functional tested and sterilized prior to first use. Protective covers and films must be completely removed before processing. NOTE: If the Broach Adapter or any of its parts are damaged or missing, please contact your MED Sales Representative for assistance. DEVICE DESCRIPTION ME1000 Adapters are accessories to the ME1000 Impact System which provide a mechanical connection between designated surgical instruments and the ME1000 Surgical Impactor. The ME1000 Broach Adapters are designed and designated for use ONLY with specific DePuy Synthes Hip System Instruments as indicated in the INTENDED USE section of these Instructions for Use. INTENDED USE The ME1000 Broach Adapters are accessories for the ME1000 Surgical Impactor and are used for connecting surgical instruments and devices to the ME1000 Surgical Impactor. The Broach Adapters are intended for patient use ONLY after careful consideration of the Instructions for Use. They are designed for use by physicians and trained medical personnel ONLY. Use the ME1000 Broach Adapters ONLY with the ME1000 Surgical Impactor and the designated DePuy Synthes Hip System Surgical Instruments shown below. SURGICAL IMPACTOR ME1000 SURGICAL IMPACTOR DePuy Synthes SUMMIT Tapered Hip System Surgical Instruments Catalog Number Item Description Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size 10! 4 English

5 DePuy Synthes TRI-LOCK Bone Preservation System Surgical Instruments Catalog Number Item Description Broach Size Starter Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Broach Size Modular Box Osteotome DePuy Synthes CORAIL AMT Hip System Surgical Instruments Catalog Number Item Description L20408 Broach Size 8 L20409 Broach Size 9 L20410 Broach Size 10 L20411 Broach Size 11 L20412 Broach Size 12 L20413 Broach Size 13 L20414 Broach Size 14 L20415 Broach Size 15 L20416 Broach Size 16 L20418 Broach Size 18 L20420 Broach Size 20 CONTRAINDICATIONS, WARNINGS, PRECAUTIONS The warnings and cautions contained within these Instructions for Use relate to the operation, processing and care of the ME1000 Broach Adapters. For additional Warnings, Cautions and contraindications that relate to ME1000 Broach Adapter use with the ME1000 Impact System, reference the ME1000 Surgical Impactor Instructions for Use.! 5 English

6 !!!!!!!!!!!!!!!!!!! SYMBOLS GLOSSARY The following symbols located on the ME1000 Surgical Impactor and its accessories (ME1000 Impact System) and/or labeling are provided and defined in this section. It is recommended that each are studied and understood for proper interpretation. SYMBOL DEFINITION Non-sterile Caution Consult Instructions for Use Class 2 Battery Charger Classified as a Class 2 power supply Device is classified as type B against electrical shock and leakage current. Manufacturer PPE (Personal Protective Equipment) Battery Charger meets CEC efficiency requirements. Temperature Limitation Humidity Limitation Atmospheric Pressure Limitation SYMBOL DEFINITION Combined Canada/U.S. UL listing mark. Combined Canada/U.S. UL classification mark. Direct Current Date of Manufacture Alternating Current Catalog number W V Watts Volt SYMBOL DEFINITION Hz Hertz Serial Number db Ah Decibel Ampere-hour Rx ONLY Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner. Wh Watt-hour This device should be disposed of in accordance with environmental protection requirements. Lock/Unlock BFP Back Feed Protection SIGNAL WORDS! 6 English

7 The following statements are located on the ME1000 Surgical Impactor and its accessories (ME1000 Impact System) and/or labeling and are intended to explain the levels of risk associated with those products. STATEMENT NOTE MEANING Identifies a safety-related issue. ALWAYS comply with this information to prevent patient and/or healthcare worker injury. Identifies a product reliability issue. ALWAYS comply with this information to prevent product damage. Supplements and/or clarifies procedural information.! Date Printed: REV A 7 English

8 ! Date Printed: REV A 8 English

9 GENERAL SAFETY INFORMATION SAFETY INSTRUCTIONS WARNINGS: Before using the Broach Adapters, READ and UNDERSTAND all instructions contained in these Instructions for Use. Pay particular attention to safety information. Failure to comply with these Instructions for Use may result in injury. Before using the Broach Adapters with other MED compatible products, READ and UNDERSTAND the Instructions for Use provided with each products to be used. Pay particular attention to safety information. Failure to comply with those instructions may result in injury. Unless otherwise indicated, ONLY use the recommended packaging as indicated in the PACKAGING section of these Instructions for Use for the storage, sterilization and transportation of the Broach Adapters. The use of other packaging may lead to extended cleaning times, inadequate sterilization and product damage. The Broach Adapters must be cleaned, lubricated, inspected, functional tested and sterilized prior to first use and after every subsequent use as indicated in these Instructions for Use. Protective covers and films must be completely removed before reprocessing. DO NOT use or process a ME1000 Broach Adapter for use if damage, wear, corrosion or missing parts are apparent or the inspection criteria are not met. Contact your MED Sales Representative for disposition and replacement. DO NOT use a Broach Adapter that has been dropped and appears damaged or is not functioning properly. Contact your MED Sales Representative for disposition and replacement. ONLY use the Broach Adapter with the ME1000 Surgical Impactor and the designated Surgical Instruments indicated in the INTENDED USE section of these Instructions for Use. Use with other equipment may result in injury and or product damage. DO NOT modify or disassemble the Broach Adapters. Modification or disassembly is considered misuse and could result in injury. CALIFORNIA PROPOSITION 65 WARNING: This product may contain chemicals, including lead, known to the State of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling. CAUTIONS: ALWAYS handle the Broach Adapter with care to prevent product damage. DO NOT drop the Broach Adapter. DO NOT expose the Broach Adapters to conditions in excess of the limitations indicated in the ENVIRONMENTAL CONDITIONS section of these Instructions for Use.! 9 English

10 PRODUCT FEATURES PRODUCT FEATURES AND SPECIFICATIONS The safe use of the Broach Adapters requires an understanding of the information in these Instructions for Use as well as knowledge of the procedure to be performed. Before use of this product, familiarize yourself with all operating features and safety instructions. LOCKING LATCH: Secures the Broach to the ME1000 Broach Adapter. The latch must be in the fully opened position to insert or remove a Broach. LOCKING LATCH CLIP: Maintains the Locking Latch in the fully closed position during use. LOCATOR: Mating feature for the Broach Pin allowing proper connection of the Broach to the ME1000 Broach Adapter. CLOVERLEAF FITTING: Mechanical interface allowing proper connection to the ME1000 Surgical Impactor. GUIDE PIN: Aligns with Locator opening of the Broach allowing proper Broach connection with the ME1000 Broach Adapter. LINKAGE: Hinged mechanism allowing Locking Latch function. See figure 39. Fig. 1 Fig. 2 Fig. 3 Dual Offset Left Broach Adapter Straight Broach Adapter Dual Offset Right Broach Adapter ! 10 English

11 PRODUCT SPECIFICATIONS Straight Broach Adapter: Weight lbs. (0.3 kg) Length in. (15.4 cm) Dual Offset Right Broach Adapter: Weight lbs. (0.7 kg) Length in. (22.2 cm) Dual Offset Left Broach Adapter: Weight lbs. (0.7 kg) Length in. (22.2 cm) PRODUCT IDENTIFICATION AND SAFETY INFORMATION The product label is located on the side of each Broach Adapter and contains product identification. Reference this label for product name, catalog number and serial number. ENVIRONMENTAL CONDITIONS USE TRANSPORTATION* STORAGE Temperature 40 C 104 F 60 C 140 F for max. 72 h 40 C 104 F 10 C 50 F 29 C 20 F 10 C 50 F Relative Humidity 90% 90% 90% 30% 10% 30% Atmospheric Pressure 1000 hpa 1000 hpa 1000 hpa 811 hpa 811 hpa 811 hpa Altitude ft ft. * Transportation conditions were tested according to ASTM D ! 11 English

12 OPERATING INSTRUCTIONS SAFETY INSTRUCTIONS WARNINGS: The Broach Adapter must be cleaned, lubricated, inspected, functional tested and sterilized prior to first use and after every subsequent use as indicated in these Instructions for Use. Protective covers and films must be completely removed before reprocessing. Following sterilization, allow the Broach Adapters to cool for at least 1 hour before use. When handling the Broach Adapters, ALWAYS use personal protective equipment (PPE) including safety goggles as recommended by the healthcare facility guidelines and cleaning agent SDS. ONLY use the Broach Adapter for its intended use. ALWAYS follow the recommended operating conditions when using the Broach Adapters. Reference the ENVIRONMENTAL CONDITIONS section of these Instructions for Use. MED recommends an alternative manual system to be readily available during each use of the ME1000 Surgical Impactor and its accessory devices in the unlikely event that technical problems occur. Before use, check for misalignment or binding of moving parts, breakage of parts, or any other condition that may affect Broach Adapters operation. Reference the INSPECTION AND FUNCTIONAL TESTING section of these Instructions for Use. DO NOT use the Broach Adapter if it does not have a secure connection to the Broach. Proper fit of the Broach with the Broach Adapter is required for proper function. DO NOT use or process a ME1000 Broach Adapter for use if damage, wear, corrosion or missing parts are apparent or the inspection criteria are not met. Contact your MED Sales Representative for disposition and replacement. DO NOT use a Broach Adapter that has been dropped and appears damaged or is not functioning properly. Contact your MED Sales Representative for disposition and replacement. ONLY use the Broach Adapter with the ME1000 Surgical Impactor and the designated Surgical Instruments indicated in the INTENDED USE section of these Instructions for Use. Use with other equipment may result in injury and or product damage. Before use, ALWAYS ensure that the Broach Adapter is secured within the ME1000 Surgical Impactor, the Locking Latch is in the locked and/or fully closed position and the Broach is secured within the Broach Adapter. Unsecured attachments during use may lead to injury. ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. To avoid injury, refer to the Instructions for Use provided by the device Manufacturer for safe and proper handling and use of Surgical Instruments. A defective Broach Adapter may not be reused. Reusing a defective Broach Adapter may lead to injury. Contact your MED Sales Representative for disposition and replacement. DO NOT modify or disassemble the Broach Adapters. Modification or disassembly is considered misuse and could result in injury. DO NOT allow petroleum-based products, penetrating oils, solvents, lubricants or other chemicals to come in contact with the Broach Adapters unless otherwise specified. These chemicals can lead to inadequate sterilization and/or damage, weaken or destroy device parts that may result in injury. CAUTIONS: ALWAYS handle the Broach Adapter with care to prevent product damage. DO NOT drop the Broach Adapter. DO NOT strike the Broach Adapter with a mallet or any other instrument. NOTES: The user of the Broach Adapters is responsible for their proper use during surgery. The Broach Adapters are intended for patient use ONLY after careful consideration of the Instructions for Use. The Broach Adapters are designed for use by physicians and trained medical personnel ONLY.! 12 English

13 BROACH ATTACHMENT & REMOVAL Broach Adapters are available to connect designated surgical instruments and devices to the ME1000 Surgical Impactor. The Instructions for Use provided with each Broach Adapter indicates the surgical instruments and devices designated for use. Attaching a Broach: See Figure 4 WARNING: ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. 1.Remove the MB1000 Battery Pack from the ME1000 Surgical Impactor, if attached. 2.Raise and hold the Locking Latch in the fully open position. 3.Insert the Broach Pin into the Broach Adapter Locator while also aligning the Broach Adapter Guide Pin with the Locator opening on the Broach. The Guide Pins are intended to seat fully into the Locator openings of each part. Fig. 4 4.Lower the Locking Latch to the fully closed position. Removing a Broach: See Figure 5 WARNING: ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. 1.Remove the MB1000 Battery Pack from the ME1000 Surgical Impactor, if attached. 2.Raise and hold the Locking Latch in the fully open position. 3.Remove the Broach by pulling it straight out of the Broach Adapter. Fig. 5 ME1000 Surgical Impactor Attachment and Removal: Reference the OPERATING INSTRUCTIONS section of the ME10000 Surgical Impactor Instructions for Use for properly attaching and removing the Broach Adapter from the ME1000 Surgical Impactor.! 13 English

14 CLEANING SAFETY INSTRUCTIONS WARNINGS: The Broach Adapter must be cleaned, lubricated, inspected, functional tested and sterilized prior to first use and after every subsequent use as indicated in these Instructions for Use. Protective covers and films must be completely removed before reprocessing. Failure to properly clean instruments prior to sterilization may lead to inadequate sterilization. Surgical instruments are used with or on patients who may harbor both recognized and unrecognized infections. To prevent the spread of infection, all reusable instruments must be thoroughly cleaned and sterilized prior to initial use and after each patient use. Instruments may have sharp edges or features. Users and reprocessors must be cautious when handling instruments. ONLY the manual cleaning method as indicated in these Instructions for Use is recommended for cleaning the Broach Adapters. Other cleaning methods were not validated and may lead to inadequate cleaning, sterilization and product damage. ONLY individuals trained and experienced in the processing of reusable medical devices should clean the Broach Adapters. Brushes and other cleaning tools should either be single-use disposable items or, if reusable, decontaminated at least daily. Contaminants could otherwise be transferred from one device to the next during cleaning and pose health risks to healthcare workers. MED recommends the Broach Adapters to be cleaned using fresh detergent solution. ALWAYS make sure detergent solution is completely rinsed from Broach Adapters before drying the devices. DO NOT allow petroleum-based products, penetrating oils, solvents, lubricants or other chemicals to come in contact with the Broach Adapters unless otherwise specified. These chemicals can lead to inadequate sterilization and/or damage, weaken or destroy device parts that may result in injury. ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. To avoid injury, refer to the Instructions for Use provided by the device Manufacturer for safe and proper handling and use of Surgical Instruments. When handling the Broach Adapters, ALWAYS use personal protective! 14 English equipment (PPE) including safety goggles as recommended by the healthcare facility guidelines and cleaning agent SDS. DO NOT use or process a ME1000 Broach Adapter for use if damage, wear, corrosion or missing parts are apparent or the inspection criteria are not met. Contact your MED Sales Representative for disposition and replacement. CAUTIONS: To avoid physical damage with other equipment, ONLY transport the Broach Adapters in their recommended packaging. Reference the PACKAGING section of these Instructions for Use. DO NOT allow soil to dry on the Broach Adapters. Maintain moisture on the devices as indicated in these Instructions for Use to prevent drying and facilitate cleaning. DO NOT use pressurized water as this may cause damage to the Broach Adapters. DO NOT use ultrasonic equipment to clean the Broach Adapters. Detergents with a ph of are recommended. Higher or lower ph values can cause damage to Broach Adapter materials. ALWAYS prepare the detergent solution per the detergent manufacturer s Instructions for Use. ALWAYS handle the Broach Adapter with care to prevent product damage. DO NOT drop the Broach Adapter. DO NOT use sharp, hard, abrasive, pointed or metal cleaning aids (e.g. pipe cleaning, wire brushes, etc.) to clean the Broach Adapters. NOTES: The cleaning and sterilization instructions provided in these Instructions for Use were validated as being capable of preparing this product for use. It is the responsibility of the health care facility to ensure that reprocessing is performed using the appropriate equipment and materials, and that designated personnel have been adequately trained in order to achieve the proper result. ALWAYS verify the cleaning and sterilization processes using your actual equipment and designated personnel to ensure proper results are achieved. The cleaning instructions in these Instructions for Use apply ONLY to the ME1000 Broach Adapters. Repeated processing according to these Instructions for Use has minimal effect on and should not compromise the performance of the Broach Adapters. End of life is normally determined by wear and damage due to use. MED used the following cleaning agents during validation of the manual cleaning instructions. These cleaning agents

15 are not listed in preference to other available cleaning agents which may perform satisfactorily. Type: Neutral ph Enzymatic Detergent Product Name: EmPower Dual Enzymatic Detergent Product Catalog Number: Detergents used on the ME1000 Broach Adapters will be in contact with the following product materials: Stainless steel. DO NOT use tools to remove ME1000 Surgical Impactor accessory attachments or to operate ME1000 Impact System movable part (e.g. locks, latches, etc.)! 15 English

16 POINT OF USE INSTRUCTIONS Recommended Point of Use Supplies for Broach Adapters: Soft lint-free cloth Tap water Point of Use Steps for Broach Adapters: See Figures 6-11 WARNING: ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. NOTES: Reference the OPERATING INSTRUCTIONS section of the ME1000 Surgical Impactor Instructions for Use for properly removing the MB1000 Battery Pack and Broach Adapters from the ME1000 Surgical Impactor. Reference the OPERATING INSTRUCTIONS of these Instructions for Use for properly removing the Broach from the Broach Adapter. 1.Remove the MB1000 Battery Pack from the ME1000 Surgical Impactor. Fig. 6 2.Remove the Broach Adapter from the ME1000 Surgical Impactor. Fig. 7 3.Remove Broaches from the Broach Adapters if attached. Fig. 8! 16 English

17 4.Position all Broach Adapter movable parts for cleaning access. Raise the Locking Latch to the fully open position. 5.Wipe the surfaces of each Broach Adapter using a clean soft lint-free cloth dampened with clean tap water to remove gross soil and debris. Fig. 9 6.Flush the cannulations in Right and Left Offset Broach Adapters using a syringe filled with clean tap water. Fig. 10 Fig. 11! 17 English

18 CONTAINMENT INSTRUCTIONS Recommended Containment Supplies & Devices for Broach Adapters: Soft lint-free towels Tap water Case Medical SteriTite Full Size Sealed Container w/ Lid w/etched MED Logo Case Medical MediTray Full Size Insert Basket Preconfigured for MED Fig. 12 Containment Steps for Broach Adapter: See Figures Load each Broach Adapter into its designated place in the MediTray Insert Basket. Place Locking Latches in the closed position prior to loading. Position the Broach Adapter in the MediTray Insert Basket with the catalog number facing up. Fig Place the loaded MediTray Insert Basket into the SteriTite Container.! 18 English

19 3.Cover Broach Adapters and ME1000 Surgical Impactor with clean soft lint-free towels dampened with clean tap water to prevent drying of soil and debris on the device prior to cleaning. 4.Place the SteriTite Container Lid over the SteriTite Container and latch securely for transport. Fig It is recommended that the Broach Adapters are reprocessed as soon as is reasonably practical following each use. Fig. 14! 19 English

20 PREPARATION FOR CLEANING INSTRUCTIONS Preparation for Cleaning Steps for Broach Adapters: See Figures WARNING: ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. NOTES: Reference the OPERATING INSTRUCTIONS section of the ME1000 Surgical Impactor Instructions for Use for properly removing the MB1000 Battery Pack and ME1000 Adapters from the ME1000 Surgical Impactor. Reference the OPERATING INSTRUCTIONS of these Instructions for Use for properly removing the Broach from the Broach Adapter. Reference the SteriTite Instructions for Use for properly reprocessing the SteriTite Container and MediTray Insert Basket. 1.Remove the Lid from the SteriTite Container. 2.Remove Broach Adapters from the MediTray Insert Basket. Fig Ensure all attachments are removed from the Broach Adapter. If the Broach Adapter is attached to a ME1000 Surgical Impactor with a connected MB1000 Battery Pack, remove the Battery Pack first before removing any other attachments. Fig. 17! 20 English Fig. 18

21 4.Position all Broach Adapter movable parts for cleaning access. Raise the Locking Latch to the fully open position. Fig. 19 MANUAL CLEANING INSTRUCTIONS Recommended Manual Cleaning Supplies for Broach Adapters: ph Neutral Enzymatic Detergent Soft lint-free cloth Various sized soft bristle nylon brushes Syringe Tap Water De-ionized (DI) water Filtered pressurized compressed air (20 psi) Manual Cleaning Steps for Broach Adapters: See Figures Rinse gross soil from all surfaces of each Broach Adapter for at least three (3) minutes under cool running tap water. Manipulate the Locking Latch of each Broach Adapter under running water to rinse hidden surfaces. Use a clean soft lint-free cloth, soft bristle nylon brush and/or syringe filled with tap water to assist in removing gross soil from each device. Fig Prepare a fresh batch of ph neutral enzymatic detergent solution according to the detergent manufacturer s written instructions.! 21 English

22 3.Using a soft bristled nylon brush and while devices are submerged in detergent solution, remove any visible soil from each Broach Adapter by thoroughly scrubbing all surfaces of each device with detergent solution for at least five (5) minutes. Manipulate the Locking Latch of each device when brushing the Linkage and to access hidden surfaces. Use a syringe filled with enzymatic detergent solution to thoroughly flush all cannulations in the Dual Offset Right and Left Broach Adapters for a minimum of three (3) times. Use a syringe filled with enzymatic detergent solution to flush any other areas that may be shielded from brushing. CLEAN WHILE FULLY SUBMERGED Fig. 21 Fig. 22 CLEAN WHILE FULLY SUBMERGED FULLY SUBMERGED Fig. 23 MANIPULATE MOVABLE PARTS WHILE SUBMERGED Fig. 24! 22 English

23 4.Rinse all surfaces of each Broach Adapter thoroughly under lukewarm running tap water for at least two (2) minutes to remove all traces of detergent solution. Manipulate the Locking Latch of each device under running water to rinse hidden surfaces. Use a syringe filled with tap water to thoroughly flush all cannulations in the Dual Offset Right and Left Broach Adapters for a minimum of three (3) times. Use a syringe filled with tap water to flush any other hard-to-reach areas. Fig. 25 Fig Visually inspect all surfaces of each Broach Adapter for remaining soil. Manipulate the Locking Latch of each device when inspecting the Linkage and Locator to inspect hidden surfaces. Pay close attention to crevices, cannulations and any hard-to-reach areas. If soil is observed, repeat steps 1-5 using a fresh batch of detergent solution. Fig. 27! 23 English

24 NOTE: Deionized (DI) water is recommended for the final rinse of the Broach Adapters. Mineral residues from hard water can stain the product and/or prevent effective cleaning 6. Rinse all surfaces of each Broach Adapter thoroughly under de-ionized (DI) water for at least two (2) minutes. Manipulate the Locking Latch of each device under running water to rinse hidden surfaces. Use a syringe filled with de-ionized (DI) water to thoroughly flush all cannulations in the Dual Offset Right and Left Broach Adapters for a minimum of three (3) times. Use a syringe filled with de-ionized (DI) water to flush any other hard-to-reach areas. 8.Dry each Broach Adapter using a clean soft lintfree cloth or filtered pressurized compressed air. Manipulate the Locking Latch of each device to dry hidden surfaces. Pay close attention to crevices, cannulations and openings where moisture can accumulate. DE-IONIZED (DI) WATER RINSE Fig Position each Broach Adapter horizontally on a clean lint-free absorbent cloth with the Locking Latch facing up. Allow each Broach Adapter to drain for at least two (2) Minutes. Fig. 29 Fig. 30! 24 English Fig. 31

25 LUBRICATION SAFETY INSTRUCTIONS WARNINGS: The Broach Adapters must be cleaned, lubricated, inspected, functional tested and sterilized prior to first use and after every subsequent use as indicated in these Instructions for Use. Protective covers and films must be completely removed before reprocessing. When handling the Broach Adapters, ALWAYS use personal protective equipment (PPE) including safety goggles as recommended by the healthcare facility guidelines and cleaning agent SDS. ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. DO NOT modify or disassemble the Broach Adapters. Modification or disassembly is considered misuse and could result in injury. ONLY use STERILIT I DRIP LUBRICATOR (REF:. JG598) to lubricate the ME1000 Broach Adapters following cleaning as indicated in these Instructions for Use. DO NOT allow petroleum-based products, penetrating oils, solvents, lubricants or other chemicals to come in contact with the Broach Adapters unless otherwise specified. These chemicals can lead to inadequate sterilization and/or damage, weaken or destroy device parts that may result in injury. After each cleaning and prior to sterilization, ALWAYS perform the lubrication instructions as indicated in these Instructions for Use. Failing to follow these instructions will lead to damage and malfunction, increasing the risk of injury. DO NOT use or process a ME1000 Broach Adapter for use if damage, wear, corrosion or missing parts are apparent or the inspection criteria are not met. Contact your MED Sales Representative for disposition and replacement. ALWAYS handle the Broach Adapter with care to prevent product damage. DO NOT drop the Broach Adapter. DO NOT strike the Broach Adapter with a mallet or any other instrument. ONLY individuals trained and experienced in the maintenance of reusable medical devices should lubricate the Broach Adapters. CAUTIONS:! 25 English

26 LUBRICATION INSTRUCTIONS Lubricate each Broach Adapter following the completion of every cleaning and prior to sterilization using STERILIT I Drip Lubricator. Follow the lubricant manufacturer s Instructions for Use (i.e. concentration/dilution and shelf life). Lubrication steps for individual Broach Adapter components are detailed in the instructions that follow. Reference the BROACH ADAPTER COMPONENT LUBRICATION SITES provided in these instructions for use for assistance in locating each component indicated in the lubrication instructions. See Figures Recommended Lubrication Supplies for Broach Adapters: STERILIT I DRIP LUBRICATOR REF: JG598 Soft lint-free cloth Lint-free absorbent cloth WARNING: ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. NOTES: A droplet symbol containing a numerical value is provided to show the recommended number of lubrication droplets for each component. See Figure 32 ALWAYS remove the Broach and the ME1000 Surgical Impactor from the Broach Adapter prior to lubrication. Fig. 32! 26 English

27 Linkage: See Figures Hold the Broach Adapter horizontally with the Locking Latch fully open and facing down to expose the underside of the Broach Adapter. 2.Put one drop of lubricant on the Linkage joint of each Broach Adapter. The Straight Broach Adapter has 2 Linkage joints. The Dual Offset Left and Right Broach Adapters have 3 Linkage Joints. 3.Raise and lower the Locking Latch several times to spread lubricant. Fig Wipe off excess lubricant from Broach Adapter housing using a clean soft lint-free cloth. Avoid wiping intended lubrication areas. Fig. 34 Fig. 35! 27 English

28 Locator: See Figure 36 1.Put one drop of lubricant on the inner wall of the Locator opening for each Broach Adapter. 2.Spread lubricant evenly along the surface using the lubricant applicator tip in a circular action. 3.Wipe off excess lubricant from Broach Adapter housing using a clean soft lint-free cloth. Avoid wiping intended lubrication areas. Fig. 37 STRAIGHT BROACH ADAPTER Locking Latch Hinge: See Figures Raise the Locking Latch to its fully open position. 2.Put one drop of lubricant in the Locking Latch joint located between the Locking Latch and the Broach Adapter housing. 3.Raise and lower the Locking Latch several times to spread the lubricant. 4.Wipe off excess lubricant from Broach Adapter housing using a clean soft lint-free cloth. Avoid wiping intended lubrication areas. Fig. 38 Fig. 36 DUAL OFFSET LEFT AND RIGHT BROACH ADAPTER! 28 English

29 Broach Adapter Component Lubrication Sites: ME1000 DUAL OFFSET LEFT AND RIGHT BROACH ADAPTER Locator Locking Latch Hinge Linkage Locking Latch Hinge Linkage Locator ME1000 STRAIGHT BROACH ADAPTER Fig. 39! 29 English

30 SAFETY INSTRUCTIONS INSPECTION AND FUNCTIONAL TESTING WARNINGS: The Broach Adapter must be cleaned, lubricated, inspected, functional tested and sterilized prior to first use and after every subsequent use as indicated in these Instructions for Use. Protective covers and films must be completely removed before reprocessing. When handling the Broach Adapters, ALWAYS use personal protective equipment (PPE) including safety goggles as recommended by the healthcare facility guidelines and cleaning agent SDS. To avoid injury, refer to the Instructions for Use provided by the device Manufacturer for safe and proper handling and use of Surgical Instruments. ONLY use the Broach Adapter for its intended use. Before use, check for misalignment or binding of moving parts, breakage of parts, or any other condition that may affect Broach Adapter operation. Reference the INSPECTION AND FUNCTIONAL TESTING section of these Instructions for Use. DO NOT use or process a ME1000 Broach Adapter for use if damage, wear, corrosion or missing parts are apparent or the inspection criteria are not met. Contact your MED Sales Representative for disposition and replacement. DO NOT use a Broach Adapter that has been dropped and appears damaged or is not functioning properly. Contact your MED Sales Representative for disposition and replacement. DO NOT use the Broach Adapter if it does not have a secure connection to the Broach. Proper fit of the Broach with the Broach Adapter is required for proper function. ONLY use the Broach Adapter with the ME1000 Surgical Impactor and the designated Surgical Instruments indicated in the INTENDED USE section of these Instructions for Use. Use with other equipment may result in injury and or product damage. Before use, ALWAYS ensure that the Broach Adapter is secured within the ME1000 Surgical Impactor, the Locking Latch is in the locked and/or fully closed position and the Broach is secured within the Broach Adapter. Unsecured attachments during use may lead to injury. ALWAYS remove the MB1000 Battery Pack from the ME1000 Surgical Impactor before attaching or removing ME1000 Adapters (including surgical instruments and devices designated for use with the Adapters), processing, lubricating and/or performing inspection. Removing the MB1000 Battery Pack will prevent unexpected operation that could cause injury. A defective Broach Adapter may not be reused. Reusing a defective Broach Adapter may lead to injury. Contact your MED Sales Representative for disposition and replacement. DO NOT modify or disassemble the Broach Adapters. Modification or disassembly is considered misuse and could result in injury. DO NOT allow petroleum-based products, penetrating oils, solvents, lubricants or other chemicals to come in contact with the Broach Adapters unless otherwise specified. These chemicals can lead to inadequate sterilization and/or damage, weaken or destroy device parts that may result in injury. Following lubrication and prior to sterilization, ALWAYS perform the functional testing instructions as indicated in these Instructions for Use. Failing to follow these instructions will lead to damage and malfunction, increasing the risk of injury. ONLY individuals trained and experienced in the maintenance of reusable medical devices should inspect and test the Broach Adapters. CAUTIONS: ALWAYS handle the Broach Adapter with care to prevent product damage. DO NOT drop the Broach Adapter. ALWAYS follow the recommended operating conditions when using the Broach Adapters. Reference the ENVIRONMENTAL CONDITIONS section of these Instructions for Use. DO NOT strike the Broach Adapter with a mallet or any other instrument. NOTE: The routine inspection and functional testing as indicated in the following instructions, are the best methods for determining the life span of the Broach Adapters. INSPECTION INSTRUCTIONS Inspection Steps for Broach Adapters:! 30 English

31 1.Visually inspect each cleaned Broach Adapter for damage and wear. Reference the following bulleted examples: Damage: (e.g. cracked, dented or separated housing, physical imperfections that can cause damage or injury, etc.) Wear: (e.g. corrosion, removed or illegible part numbers, symbols and markings, etc.) 2.If damage or wear is detected, contact your MED Sales Representative for disposition and replacement. DO NOT sterilize, or allow a ME1000 Broach Adapter with damage or wear to be reused. 4.If no damage or wear is detected, immediately proceed to the following functional testing instructions. Recommended Functional Testing Supplies for Broach Adapters: Lint-free Surgical Towel FUNCTIONAL TESTING INSTRUCTIONS Insertion / Removal of Attachments and Movable Parts: See Figures Verify the following criteria for all Inspected Broach Adapters while performing the functional tests indicated below. Locking Latch movement is smooth and without blockage. Insertion and removal of surgical instrument from each Broach Adapter is smooth and without blockage. ME1000 Surgical Impactor Insertion and removal of each Broach Adapter is smooth and without Blockage. Broach Attachment: See Figures Raise and hold the Locking Latch of a cleaned, lubricated and inspected Broach Adapter in the fully open position. Fig. 40! 31 English

32 2.Using a clean lint free surgical towel, cover the cutting surface of a cleaned Broach that is designated for use with the ME1000 Broach Adapters. 3.Insert the Broach into the Broach Adapter and lower the Locking Latch to the fully closed position. Fig While holding the Broach Adapter with one hand and while placing the other hand around the cloth covered Broach, Pull the Broach forward and backward to verify a secure, locked connection while also verifying the Locking Latch remains closed. Fig Raise and hold the Locking Latch in the fully open position and remove the Broach. 6.Repeat steps 1-6 for all remaining Broach Adapters, ensuring all Broach Adapters are functional tested with an appropriate Broach prior to sterilization. Fig. 43! 32 English

33 Broach Adapter Attachment: See Figures NOTE: Reference the OPERATING INSTRUCTIONS section of the ME1000 Surgical Impactor Instructions for Use for properly attaching and removing the Broach Adapter from the ME1000 Surgical Impactor. 5.Remove the MB1000 Battery Pack from the ME1000 Surgical Impactor, if attached. Fig Insert a cleaned, lubricated and inspected Broach Adapter into the Locking Collar of a cleaned, lubricated and inspected ME1000 Surgical Impactor and rotate the Locking Collar to the Locked position. Fig While holding the ME1000 Surgical Impactor with one hand, pull the Broach Adapter forward and backward to verify a secure, locked connection. Fig Rotate the ME1000 Surgical Impactor Locking Collar to the unlocked position and remove the Broach Adapter. 9.Repeat steps 1-3 for all remaining cleaned and lubricated Broach Adapters, ensuring all Broach Adapters are functional tested with the ME1000 Surgical Impactor prior to sterilization. Fig. 47! 33 English

34 PACKAGING SAFETY INSTRUCTIONS WARNINGS: When handling the Broach Adapters, ALWAYS use personal protective equipment (PPE) including safety goggles as recommended by the healthcare facility guidelines and cleaning agent SDS. Unless otherwise indicated, ONLY use the recommended packaging as indicated in the PACKAGING section of these Instructions for Use for the storage, sterilization and transportation of the Broach Adapters. The use of other packaging may lead to extended cleaning times, inadequate sterilization and product damage. ALWAYS make sure the Broach Adapters have been properly cleaned, lubricated, inspected, functional tested and are completely dry prior to sterile packaging. DO NOT use or process a ME1000 Broach Adapter for use if damage, wear, corrosion or missing parts are apparent or the inspection criteria are not met. Contact your MED Sales Representative for disposition and replacement. DO NOT use a Lid on the MediTray Insert Basket for packaging the ME1000 Broach Adapters. The use of a MediTray Lid for ME1000 Surgical Impactor sterilization is not recommended and may lead to inadequate sterilization of the device. ONLY Trays and Containers manufactured for or Distributed by MED should contain MED products as indicated by MED. Use of other containment devices are not recommended and may lead to extended cleaning times, inadequate sterilization and product damage. For Preconfigured Tray, Basket and Container layouts, areas designated for specific devices shall ONLY contain those devices and in the configuration specified by MED. DO NOT add devices to a preconfigured Tray, Basket or Container in excess of its defined device configuration. Overcrowding and/or incorrect loading can result in product damage and impact the effectiveness of sterilization. ONLY load the devices indicated in the TABLE 1 PACKAGING section of these Instructions for Use into the MediTray Insert Basket Preconfigured for MED. CAUTION: ALWAYS handle the Broach Adapter with care to prevent product damage. DO NOT drop the Broach Adapter. NOTES: The validated sterilization instructions provided in these Instructions for Use are ONLY applicable to the product configurations and packaging methods as indicated in the PACKAGING section of these Instructions for Use. Reference the SteriTite Instructions for Use for the recommended use of disposable sterilization accessories. (i.e. Chemical Indicators, Load Cards, Tamper Evident Seals, etc.) with the MediTray Insert Basket and the SteriTite Container.! 34 English

35 PACKAGING METHODS The packaging method recommended for the sterilization, sterile storage and transport of the ME1000 Broach Adapters is described below and specified in the PACKAGING INSTRUCTIONS section of these Instructions for Use. No other packaging method is recommended for use with this product. Packaging Method: SteriTite Container w/meditray : SteriTite Full Size Sealed Container w/lid and w/etched MED Logo with enclosed MediTray Full Size Insert Basket Preconfigured for MED. See Figures For non-sterile storage of the Broach Adapters, ONLY use the SteriTite Container w/meditray packaging method or if in good condition, the original product packaging. Contact your MED Sales Representative if replacement product packaging is needed. PACKAGING INSTRUCTIONS Recommended Packaging for Surgical Impactor: Case Medical SteriTite Full Size Sealed Container w/lid w/etched MED Logo REF: SC06FG Case Medical SteriTite Disposable Filters Cellulosic 7.5" Dia. 1000/pk. (For use with REF: SC06FG SteriTite Full Size Sealed Container) REF: SCF01 Case Medical MediTray Full Size Insert Basket Preconfigured for MED REF: BSKF06 Packaging Steps for Broach Adapters: See Figures WARNINGS: ALWAYS make sure the Broach Adapters have been properly cleaned, lubricated, inspected, functional tested and are completely dry prior to sterile packaging. ONLY load the devices indicated in the TABLE 1 PACKAGING section of these Instructions for Use into the MediTray Insert Basket Preconfigured for MED. NOTE: Reference the SteriTite Instructions for Use for the recommended use of disposable sterilization accessories. (i.e. Chemical Indicators, Load Cards, Tamper Evident Seals, etc.) with the MediTray Insert Basket and the SteriTite Container. 1.Load clean, lubricated and dry Broach Adapters into their designated place in the MediTray Insert Basket. Place Locking Latches in the closed position prior to loading. Position the Broach Adapter in the MediTray Insert Basket with the catalog number facing up. Fig. 48! 35 English

36 2.Place the loaded MediTray Insert Basket into the SteriTite Container. SteriTite Sterilization Container Base and Loaded MediTray Insert Basket BSKF06 MediTray Full Size Insert Basket Preconfigured for MED SC06FG SteriTite Full Size Sealed Container Base w/etched MED Logo Fig Place SteriTite Filters into the filter housings on the SteriTite Container Lid as indicated in the Case Medical SteriTite Instructions for Use. 4.Place the SteriTite Container lid over the SteriTite Container and latch securely.. SteriTite Sterilization Container Base, Lid and enclosed MediTray Insert Basket SteriTite Full Size Container Lid for SC06FG w/etched MED Logo BSKF06 MediTray Full Size Insert Basket Preconfigured for MED SC06FG SteriTite Full Size Sealed Container Base w/etched MED Logo Fig. 50! 36 English

37 Table 1: Load Plan for MediTray Full Size Insert Basket Preconfigured for MED REF Product Description QTY ME1000 SURGICAL IMPACTOR ME1000 STRAIGHT BROACH ADAPTER ME1000 DUAL OFFSET LEFT BROACH ADAPTER ME1000 DUAL OFFSET RIGHT BROACH ADAPTER 1 LOADED BSKF06 MEDITRAY INSERT BASKET PRECONFIGURED FOR MED ME1000 Surgical Impactor ME1000 Straight Broach Adapter ME1000 Dual Offset Left Broach Adapter ME1000 Dual Offset Right Broach Adapter Fig. 51 Table 2: Load Dimensions for SteriTite Container and MediTray Insert Basket REF Product Description Dimensions SC06FG BSKF06 STERITITE FULL SIZE SEALED CONTAINER W/LID W/ETCHED MED LOGO MEDITRAY FULL SIZE INSERT BASKET PRECONFIGURED FOR MED 23.5 x 11 x 6 (59.7 x 28 x 15.24cm) 21.3" x 9.7" x 6.0" (54.1 x 24.6 x 15.2cm)! 37 English

38 STERILIZATION SAFETY INSTRUCTIONS WARNINGS: When handling the Broach Adapters, ALWAYS use personal protective equipment (PPE) including safety goggles as recommended by the healthcare facility guidelines and cleaning agent SDS. The Broach Adapters must be cleaned, lubricated, inspected, functional tested and sterilized prior to first use and after every subsequent use as indicated in these Instructions for Use. Protective covers and films must be completely removed before reprocessing. ONLY individuals trained and experienced in the processing of reusable medical devices should sterilize the Broach Adapters. DO NOT use or process a ME1000 Broach Adapter for use if damage, wear, corrosion or missing parts are apparent or the inspection criteria are not met. Contact your MED Sales Representative for disposition and replacement. ALWAYS make sure the Broach Adapters have been properly cleaned, lubricated, inspected, functional tested and are completely dry prior to sterilization. DO NOT use a Lid on the MediTray Insert Basket for packaging the ME1000 Broach Adapters. The use of a MediTray Lid for ME1000 Surgical Impactor sterilization is not recommended and may lead to inadequate sterilization of the device. Autoclave design and performance can affect the sterilization process. ALWAYS verify the process using your actual equipment and designated personnel. ONLY use the recommended sterilization methods as indicated in these Instructions for Use. Using other sterilization methods may lead to inadequate sterilization and/or product damage. ALWAYS Follow the recommended dry times to prevent moisture accumulation. Moisture may prevent proper sterilization and/or damage the Broach Adapters. Following sterilization, allow Broach Adapters to cool for at least 1 hour before use. CAUTIONS: DO NOT dry Broach Adapters in an oven. ONLY compressed air and/or clean soft lint-free cloth are recommended for drying this product. Residual moisture from cleaning may lead to product damage. DO NOT expose Broach Adapters to conditions in excess of the Sterilization Exposure Time and Temperature indicated in these Instructions for Use. Exceeding recommended steam sterilization exposure times or temperatures for Broach Adapters may reduce product life, affect performance and/or damage the product. MED does not recommend immediate-use steam sterilization for Broach Adapters. NOTES: The cleaning and sterilization instructions provided in these Instructions for Use were validated as being capable of preparing this product for use. It is the responsibility of the health care facility to ensure that reprocessing is performed using the appropriate equipment and materials, and that designated personnel have been adequately trained in order to achieve the proper result. ALWAYS verify the cleaning and sterilization processes using your actual equipment and designated personnel to ensure proper results are achieved. The final responsibility for verification of sterilization techniques lies directly with the healthcare facility. To ensure the efficacy of health care facility processing, all cycles and methods should be verified for different sterilization chambers, packaging methods, and/or various loading configurations. Under certain classifications of risk, the World Health Organization (WHO), or local regulatory authorities recommend special CJD (Creutzfeldt-Jakob Disease) inactivation processing procedures. Consult WHO and local regulations for further information. The sterilization instructions provided in these Instructions for Use apply ONLY to the ME1000 Broach Adapters. Repeated processing according to these Instructions for Use has minimal effect on and should not compromise the performance of the Broach Adapters. End of life is normally determined by wear and damage due to use. STERILIZATION INSTRUCTIONS Sterilization Steps for Broach Adapters:! 38 English

INSTRUCTIONS FOR USE (IFU)

INSTRUCTIONS FOR USE (IFU) !! INSTRUCTIONS FOR USE (IFU) ME1000 SURGICAL IMPACTOR 1000-00-101 Rx ONLY English (EN)! 1 English TABLE OF CONTENTS INTRODUCTION... 2 GENERAL PRODUCT INFORMATION... 4 HOW SUPPLIED... 4 DEVICE DESCRIPTION...

More information

PM-X IR SURGICAL POWER & ACCESSORIES

PM-X IR SURGICAL POWER & ACCESSORIES PM-X00-770-IR-12.13 SURGICAL POWER & ACCESSORIES Table of Contents Introduction Page 4 Intended Use Page 4 Warning Page 4 Caution Page 5 Notes Page 5 Explanation of Symbols Page 5 Features Page 6 Cleaning

More information

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities. User s Manual Battery Powered Driver. For tapping and inserting screws into varied bone densities. Table of Contents Introduction Battery Powered Driver 2 Operating Instructions Assembly 3 Screw Insertion

More information

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient. Ref. : 1 of 5 PURPOSE AND SCOPE To ensure all staff working in the dental practice responsible for reprocessing of medical instruments and equipment are aware of the correct packaging and wrapping that

More information

Symmetry Surgica l QUAD-LOCK Sterilization Container System

Symmetry Surgica l QUAD-LOCK Sterilization Container System Symmetry Surgica l QUAD-LOCK Sterilization Container System Symmetry Surgical Inc. 3034 Owen Drive Antioch, TN 37013 USA 1-800-251-3000 Fax: 1-615-964-5566 www.symmetrysurgical.com EC REP Symmetry Surgical

More information

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System Quantum OPS Inc. PO Box 4808 Chattanooga, TN 37405 423-805-7999 888-483-9879 contact@quantumops.com v.2019 Copyright

More information

LDR Brachytherapy Seed Sterilization and Sorting Tray

LDR Brachytherapy Seed Sterilization and Sorting Tray LDR Brachytherapy Seed Sterilization and Sorting Tray Table of Contents General Precautions... 2 Customer Responsibility... 3 Description... 4 Features and Specifications... 5 Operation... 6 Changing Covers

More information

Heyinovo. Disposable Biopsy Valves User Manual. Technical Publications. Document No: WI-RD-13-M07, Rev. B

Heyinovo. Disposable Biopsy Valves User Manual. Technical Publications. Document No: WI-RD-13-M07, Rev. B Heyinovo Disposable Biopsy Valves User Manual Technical Publications Document No: WI-RD-13-M07, Rev. B Copyright By Wilson Instruments (SHA) Co., Ltd. Regulatory Requirement This product complies with

More information

Reprocessing Instructions and Inspecton Criteria

Reprocessing Instructions and Inspecton Criteria Reprocessing Instructions and Inspecton Criteria DEVICE DESCRIPTION: The SteriTite universal container is a rigid, reusable, sealed medical sterilization packaging system validated for steam and low temperature

More information

Bard. BI-DIRECTIONAL and KELLY-WICK TUNNELERS. Instructions For Use. PK Rev. 1 04/06

Bard. BI-DIRECTIONAL and KELLY-WICK TUNNELERS. Instructions For Use. PK Rev. 1 04/06 Bard BI-DIRECTIONAL and KELLY-WICK TUNNELERS Instructions For Use PK0114100 Rev. 1 04/06 Bard Bi-Directional and Kelly-Wick Tunnelers Caution: Federal (USA) law restricts this device to sale by or on the

More information

OWNER S MANUAL. Item #14103

OWNER S MANUAL. Item #14103 TRI-BALL HITCH WITH CLEVIS OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

Retractor Kit Rev: D. Instruction For Use NEXT ORTHOSURGICAL 3270 CORPORATE VIEW, SUITE A VISTA CA /1/14

Retractor Kit Rev: D. Instruction For Use NEXT ORTHOSURGICAL 3270 CORPORATE VIEW, SUITE A VISTA CA /1/14 Instruction For Use NEXT ORTHOSURGICAL 3270 CORPORATE VIEW, SUITE A VISTA CA 92081 8/1/14 Summary 1. User manual... 3 1.1. Presentation... 3 1.1.1. Destination... 3 1.1.2. Surgical context... 3 1.1.3.

More information

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER EDGE12 SLICER THE EDGE12 SLICER MODEL EDGE12-1 (120/60/1 voltage) EDGE12-2 (220/50/1 voltage) ML-136246 ML-136247 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 35283 (July

More information

USER INSTRUCTIONS. Applicable to Lanyard : REF. NO. : ,

USER INSTRUCTIONS. Applicable to Lanyard : REF. NO. : , USER INSTRUCTIONS Applicable to Lanyard : REF. NO. : 10185600, 10185613 Manufacturer : MSA Europe GmbH, Schlüsselstr. 12, CH- 8645 Rapperswil-Jona Switzerland Body : SATRA Technology Centre, Wyndham Way,

More information

Instructions for Use A-dec Quick-Disconnect Syringes

Instructions for Use A-dec Quick-Disconnect Syringes Instructions for Use A-dec Quick-Disconnect Syringes Contents Basic Operation...1 Adjustments... 4 Asepsis... 6 Specifications, Warranty, and Product Service... 8 Basic Operation Water, Air, and Spray

More information

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug Medium-Duty Electric Slicers 40950 40951 Item Model Description Drive Peak HP Voltage Amps Hz Plug 40950 SLM250/S 10 Knife Medium-Duty Slicer 1/3 2.5 Belt 120 60 5-15P 40951 SLM300P/S 12 Knife Medium-Duty

More information

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY ONE YEAR LIMITED WARRANTY INSTRUCTION MANUAL The original registered owner of this product should contact SKYFOOD EQUIPMENT LLC at 305-868-16 for any warranty problems or service. SKYFOOD EQUIPMENT LLC

More information

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles Directions for Use Thank you for choosing an ADC Satin Laryngoscope. Device Description and Intended Use A Laryngoscope

More information

STERILE CONTAINER SYSTEMS

STERILE CONTAINER SYSTEMS »» Extra Long Size EXTRA LONG SIZE 280 mm 710 mm h Specificiations Lid (Perforated) Lid (Perforated) Sizes Box (Non Perforated) Box (Perforated) TK6-2010 TK6-2040 TK6-2011 TK6-2041 h=120 mm TK6-2012 TK6-2013

More information

300 ft. 5/8 Hose wagon

300 ft. 5/8 Hose wagon 300 ft. 5/8 Hose wagon Model 95956 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. (Garden hose is not included).

More information

Instructions for Use: Duodenoscope Sampling Kit

Instructions for Use: Duodenoscope Sampling Kit Instructions for Use: Duodenoscope Sampling Kit Brand Name of Product Generic Name of Product Product Code Number(s) Intended Use Duodenoscope Sampling Kit Endoscope sampling and culturing kit CK-250,

More information

STERILE CONTAINER SYSTEMS

STERILE CONTAINER SYSTEMS »» Extra Long Size EXTRA LONG SIZE 280 mm 710 mm h h 1 Specificiations Lid (with barrier) Lid (with barrier) Box (Non Perforated) Box (with barrier) TK7-2010 TK7-2040 TK7-2011 TK7-2041 TK7-2012 TK7-2013

More information

MAX Series 9514 OPERATOR S MANUAL

MAX Series 9514 OPERATOR S MANUAL MAX Series 9514 OPERATOR S MANUAL Persons under age 18 are not permitted to operate or have accessibility to operate this equipment per U.S. Dept. Of Labor Employment Standards Administration Fact Sheet

More information

FORM (Apr. 2006)

FORM (Apr. 2006) 2212 Slcier MODEL 2212 SLICER MODEL 2212 ML-136132 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 35215 (Apr. 2006) Installation, Operation, and Care of MODEL 2212 Slicer

More information

For the diagnosis of Hirschsprung s Disease

For the diagnosis of Hirschsprung s Disease For the diagnosis of Hirschsprung s Disease Suction Rectal Biopsy System Suitable for use with: Neonates - Adolescents - Adults World s #1 System Patent No US 7,479,117 B2 Controlled Consistent Rectal

More information

1000M MANUAL Signature Series Slicer OPERATORS MANUAL

1000M MANUAL Signature Series Slicer OPERATORS MANUAL 1000M MANUAL Signature Series Slicer OPERATORS MANUAL Persons under age 18 are not permitted to operate or have accessibility to operate this equipment per U.S. Dept. Of Labor Employment Standards Administration

More information

electric knife sharpener

electric knife sharpener electric knife sharpener USER GUIDE Now that you have purchased a Kitchen Living product you can rest assured in the knowledge that as well as your year parts and labour guarantee you have the added peace

More information

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End 3875 Cypress Drive Petaluma, CA 94954 800.228.2555 707.773.1100 Fax 707.773.1180 www.gcx.com Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End Products covered

More information

Table of Contents. Safety... 2 Specifications... 4 Assembly Maintenance... 6 Parts List... 7 Warranty... 8

Table of Contents. Safety... 2 Specifications... 4 Assembly Maintenance... 6 Parts List... 7 Warranty... 8 Table of Contents Safety... Specifications... 4 Assembly... 4 Maintenance... 6 Parts List... 7 Warranty... 8 WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you to

More information

SURGICAL TECHNIQUE. Legend Acetabular Shell

SURGICAL TECHNIQUE. Legend Acetabular Shell SURGICAL TECHNIQUE Legend Acetabular Shell The following technique is a general guide for instrumentation of the Legend Acetabular Shell. It is expected that the surgeon is already familiar with the fundamentals

More information

1 Pan - 6 Ways to Cook! Works in the Oven & On All Stovetops! electric gas ceramic induction. Broil Bake Sauté Fry Steam Braise

1 Pan - 6 Ways to Cook! Works in the Oven & On All Stovetops! electric gas ceramic induction. Broil Bake Sauté Fry Steam Braise *only use non-metal utensils 1 Pan - 6 Ways to Cook! Broil Bake Sauté Fry Steam Braise Non-stick Cerami-Tech Ceramic Coating Even Heating Good for All Surfaces Easy Cleaning Durable, Stain Resistant Coating

More information

Instrument Care and Handling Guide

Instrument Care and Handling Guide Instrument Care and Handling Guide INDEX Basic Guidelines to Reprocessing...2 Manual Cleaning...3 Ultrasonic Cleaning...3 Inspection...4 Lubrication...4 Sterilizing...4 Storage...5 Handling...5 Repairs...5

More information

TUCSON PATIO AWNING USE & MAINTENANCE

TUCSON PATIO AWNING USE & MAINTENANCE TUCSON PATIO AWNING USE & MAINTENANCE Toll Free 877-792-1775 Fax 877-792-0031 swsuncontrolpro.com sales@swsuncontrol.com 1 INTRODUCTION...3 2 SAFETY...3 2.1 General safety information... 3 2.2 Safety devices...

More information

BR B Bike Rack Instructions

BR B Bike Rack Instructions IMPORTANT NOTE: It is common that vehicles with lids and hatches have a single rear wiper. It is important that you make yourself aware that the wiper cannot be used while the rack is attached to the vehicle.

More information

Application Tooling Specification

Application Tooling Specification Order No. 200218-3100 FEATURES Application Tooling Specification A full cycle ratcheting hand tool ensures complete crimps Long handles for comfortable crimping with reduced crimping force and a safety

More information

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION SINGLE BURNER STOVE OPERATING INSTRUCTIONS PARTS IDENTIFICATION Electronic Lighter Ignites the burner. Liquid Guard Holds liquid overflow. Windshield Prevents flame from being extinguished by wind. Ensures

More information

JARVIS. Model 70 Airsnip Air Powered Scissors

JARVIS. Model 70 Airsnip Air Powered Scissors Air Powered Scissors EQUIPMENT SELECTION... Ordering No. Airsnip Model 70... 4019009 Air Filter/Regulator/Lubricator.. 3022003 Balancer... 1350084 Power--Pak (250 PSI)... 4026016 TABLE OF CONTENTS... Page

More information

Pediatric Lower Body Warming Blanket Model B203 Instructions for Use

Pediatric Lower Body Warming Blanket Model B203 Instructions for Use Pediatric Lower Body Warming Blanket Model B203 Instructions for Use Manufactured by: Augustine Temperature Management, LLC 6581 City West Parkway Eden Prairie, MN 55344 USA TEL 952.465.3500 FAX 952.465.3501

More information

FagronLab FG. Semi-automatic capsule filling machine. User Manual

FagronLab FG. Semi-automatic capsule filling machine. User Manual Semi-automatic capsule filling machine User Manual Table of contents 1. Introduction... 4 2. Service.. 4 3. Warranty... 4 4. Overview... 5 System features... 5 FagronLab FG-1 Filler Base & Orienter Base...

More information

WARMING BLANKETS INSTRUCTIONS FOR USE

WARMING BLANKETS INSTRUCTIONS FOR USE WARMING BLANKETS INSTRUCTIONS FOR USE INTRODUCTION HotDog Warming Blankets and optional Disposable Sheets are part of the HotDog Patient Warming System. These instructions apply to the following catalog

More information

Operator s Manual. Wedgemaster 606N 808N 808SG ENGLISH

Operator s Manual. Wedgemaster 606N 808N 808SG ENGLISH ENGLISH Wedgemaster 606N 808N 808SG Thank you for purchasing this Vollrath Food Processing Equipment. Before operating the equipment, read and familiarize yourself with the following operating and safety

More information

85 Heart Lake Road South Brampton, Ontario, Canada L6W 3K2 Phone: Fax:

85 Heart Lake Road South Brampton, Ontario, Canada L6W 3K2 Phone: Fax: Big Joe by Blue Giant Warranty AC Power Drive Straddle Trucks (PDS) AC Power Pallet Trucks (WPT45, D40) AC Power Rider Trucks (WRT-60) AC Power Counterbalanced Truck (CB-22) AC Power Task Support Vehicle

More information

S E L E C T I O N. Abdominal Crunch. User manual

S E L E C T I O N. Abdominal Crunch. User manual and S E L E C T I O N T H E S T R E N G T H E V O L U T I O N User manual and and The identification plate of the and manufacturer, affixed along side the seat on the frame of the weight stack, gives the

More information

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL BRIEF INTRODUCTION Split body (2-piece) valve allows easy replacement of gasket, seal, and seats without special tools. Series 90D ball valves use floating ball design. Induced by the line pressure the

More information

Motorized retractable awning

Motorized retractable awning Motorized retractable awning Model 95295 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions Therme storage water heater Table of contents Symbols used... 8 Installation instructions Water supply... 9 Choice of location... 9 Installation of the Therme... 9 Fitting the draining and venting valve...

More information

SB3T. Roll-InBuddy + Tilt. Dignity + Ease + Comfort. Product features include:

SB3T. Roll-InBuddy + Tilt. Dignity + Ease + Comfort. Product features include: SB3T Roll-InBuddy + Tilt The revolutionary tilt option incorporated into the Roll-InBuddy Tilt allows for pressure release as well as a more thorough bathing experience for the user and easier reach for

More information

Manual Awning. Assembly Instructions. Product No Toll-free:

Manual Awning. Assembly Instructions. Product No Toll-free: Manual Awning Product No. 088-30- Instructions Toll-free: -877-483-679 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this manual for future reference. 3 Table

More information

Blue Series Hot Melt Hose with RediFlext II Hanger System

Blue Series Hot Melt Hose with RediFlext II Hanger System Instruction Sheet P/N 1124594_01 Blue Series Hot Melt Hose with RediFlext II Hanger System Safety WARNING! Allow only personnel with appropriate training and experience to operate or service the equipment.

More information

Procedure Guidelines Protocol Title:

Procedure Guidelines Protocol Title: Procedure Guidelines Protocol Title: Endotracheal Intubation Original Adoption Date: 05/2001 Past Protocol Updates 05/2001, 12/2006, 01/2008, 09/2010 Date of Most Recent Update: December 26, 2013 Medical

More information

Operation Manual SUPER BEAST Multi-tool SC-11M-10

Operation Manual SUPER BEAST Multi-tool SC-11M-10 Operation Manual SUPER BEAST Multi-tool SC-11M-10 Technical Specifications General Safety/Operating Instructions Attaching/Changing the Head Using the SUPER BEAST as a Cutter Using the SUPER BEAST as a

More information

ALPINE SLIDEOUT COVER

ALPINE SLIDEOUT COVER INSTALLATION MANUAL ALPINE SLIDEOUT COVER RV Read this manual before installing or using this product. Failure to follow the instructions and safety precautions in this manual can result in personal injury

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL General Safety Rules WARNING! Read all instructions. Failure to follow all instructions listed below may result in electric shock, fire and/ or serious injury. The term power

More information

PLEASE READ BEFORE USE AND SAVE THESE INSTRUCTIONS

PLEASE READ BEFORE USE AND SAVE THESE INSTRUCTIONS Sauce Flip Pan PLEASE READ BEFORE USE AND SAVE THESE INSTRUCTIONS Thank you for purchasing Cook s Companion Sauce Flip Pan. This pan is designed to be one of the most used pans in your kitchen. The Fusion

More information

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374 I N ST R UC 1712E T I ON MODELS 1612E, 1712E & 1712RE SLICERS S ML-104546 ML-104547 ML-104548 1612E 1712E 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374 FORM 19238 Rev. B (10-97) TABLE OF CONTENTS GENERAL......................................................................

More information

AUTO REWIND HOSE REEL WITH 50 FOOT HOSE. Model 46320

AUTO REWIND HOSE REEL WITH 50 FOOT HOSE. Model 46320 AUTO REWIND HOSE REEL WITH 50 FOOT HOSE Model 46320 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2001 by

More information

HANG GLIDER (RECHARGEABLE)

HANG GLIDER (RECHARGEABLE) HANG GLIDER (RECHARGEABLE) 91192 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com IMPORTANT: If damage is caused due to

More information

accidents which arise due to non-observance of these instructions and the safety information herein. CAUTION:

accidents which arise due to non-observance of these instructions and the safety information herein. CAUTION: AUTO REWIND HOSE REEL Model: 7640 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This

More information

ROOFTOP CARGO BAG (FRONT OF VEHICLE) HOOK (x4) ATTACHMENT STRAP (x4)

ROOFTOP CARGO BAG (FRONT OF VEHICLE) HOOK (x4) ATTACHMENT STRAP (x4) CargoPack, DryTop, SoftTop ROOFTOP CARGO BAG Zipper Flap HOOK (x4) Grab handle ATTACHMENT STRAP (x4) (FRONT OF VEHICLE) Naked roof STRAP (2X) IMPORTANT WARNING IT IS CRITICAL THAT ALL YAKIMA RACKS AND

More information

Operating Instructions

Operating Instructions Operating Instructions High Throughput Dialysis MODEL HTD96b www.htdialysis.com HTD96b : Operating Instructions Components Universal Base Unit Teflon block assembly: 9 Teflon bars, labeled sequentially

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS 1. DESCRIPTION: Hatch Tent 2. APPLICATION: See dealer application chart 3. PART NUMBER: 999T7 XR100 and 999T7 XY100 4. KIT CONTENTS: Item Qty Description A 1 Tent

More information

Cast Iron Cookware Ustensiles de cuisson en fonte Utensilios de cocina de hierro fundido INSTRUCTIONS INSTRUCTIONS INSTRUCCIONES

Cast Iron Cookware Ustensiles de cuisson en fonte Utensilios de cocina de hierro fundido INSTRUCTIONS INSTRUCTIONS INSTRUCCIONES Cast Iron Cookware Ustensiles de cuisson en fonte Utensilios de cocina de hierro fundido INSTRUCTIONS INSTRUCTIONS INSTRUCCIONES WELCOME TO THE WORLD OF KITCHENAID. We re committed to helping you create

More information

Quick and Dirty of Cleaning and Disinfection Designated Officer Training January 17, 2013

Quick and Dirty of Cleaning and Disinfection Designated Officer Training January 17, 2013 Quick and Dirty of Cleaning and Disinfection Designated Officer Training January 17, 2013 Outline Terminology Spaulding Classifications Ideal Disinfectant? Environmental Cleaning Blood and Body Fluid Spill

More information

Model 698/ and Model in 1 Hose Reel Owner s Manual

Model 698/ and Model in 1 Hose Reel Owner s Manual Model 698/694 200 and Model 706 100 4 in 1 Hose Reel Owner s Manual 698/694 706 VISIT OUR WEBSITE: WWW.LIBERTYGARDENPRODUCTS.COM OR CALL US TOLL FREE AT 1-866-820-5805 LIBERTY GARDEN PRODUCTS, INC. 500

More information

CRD120SC TUBING CUTTER

CRD120SC TUBING CUTTER CRD120SC TUBING CUTTER OPERATIONS MANUAL 1 VERSION 2.1 LAST EDITED 05.01.2018 cleanroomdevices.com Table of Contents Table of Contents....2 1.0 General Product & Safety Information... 3 1.1 Product Information

More information

OWNER'S MANUAL CAMPOUT TABLE OF CONTENTS

OWNER'S MANUAL CAMPOUT TABLE OF CONTENTS OWNER'S MANUAL CAMPOUT RV Before operating the awning, carefully review the Owner's Manual. The manual contains important safety information, detailed operating instructions, common maintenance procedures

More information

Installation and User s Manual 12 x 10 MOTORIZED AWNING

Installation and User s Manual 12 x 10 MOTORIZED AWNING 12 x 10 MOTORIZED AWNING Installation and User s Manual 12 x 10 MOTORIZED AWNING 088-1763-0 Stop Please read and understand this manual before any assembly or use of this product. Before beginning assembly

More information

Cordless Electric Teakettle. Model 685

Cordless Electric Teakettle. Model 685 Cordless Electric Teakettle Model 685 Important Safeguards When using electrical appliances, basic safety precautions should always be followed, including the following: 1. Read all instructions. 2. Do

More information

Owner's Manual. Safety Instructions. This Product is Produced Exclusively by

Owner's Manual. Safety Instructions. This Product is Produced Exclusively by Product May Vary Slightly From Pictured. Owner's Manual Safety Instructions! WARNING This equipment is for home use only. Do not use in institutional or commercial applications. Failure to follow this

More information

V. Mueller. Genesis Low Temperature Reusable Rigid Sterilization Container System Operator s Manual

V. Mueller. Genesis Low Temperature Reusable Rigid Sterilization Container System Operator s Manual V. Mueller Genesis Low Temperature Reusable Rigid Sterilization Container System Operator s Manual Contact Information: CareFusion 75 North Fairway Drive Vernon Hills, IL 60061 USA 800-323-9088 Cleveland,

More information

OUTDOOR SERIES Mosquito protection you don t spray on Repels mosquitoes, black flies and flying insects Provides 15 x15 ft of repellency, the size of

OUTDOOR SERIES Mosquito protection you don t spray on Repels mosquitoes, black flies and flying insects Provides 15 x15 ft of repellency, the size of OUTDOOR SERIES Mosquito protection you don t spray on Repels mosquitoes, black flies and flying insects Provides 15 x15 ft of repellency, the size of an average deck LEDs provide safe, ambient light Each

More information

Two Piece Low Torque Kelly Valve

Two Piece Low Torque Kelly Valve Two Piece Low Torque Kelly Valve Disassembly and Assembly Procedures Global Manufacturing, Inc. Lafayette, Louisiana USA 70508 Ph (337) 237-1727 Fax (337) 232-9353 SAFETY CONSIDERATIONS Safety glasses

More information

The Cube Birthing Couch

The Cube Birthing Couch The Cube Birthing Couch Instructions for Use CROYDE MEDICAL Repositioning Care 1 of 8 Specifications Mattress core: Combustion Modified Polyether. Mattress topper: High Density Visco-elastic Memory foam.

More information

Chemical Spill Response Guide

Chemical Spill Response Guide Chemical Spill Response Guide EMERGENCY CONTACT PHONE NUMBERS Contact Security Services Phone Number 902 494 4109 (Halifax) 902 893 4190 (Truro) 902 494 2495 (Halifax) 902 893 2446 (Truro) Contents INTRODUCTION...

More information

MODEL # 1 MANUAL CAN OPENER

MODEL # 1 MANUAL CAN OPENER REV.B SERVICE MANUAL MODEL # 1 MANUAL CAN OPENER Model #1 Can Opener Assembly Procedure The Model #1 can opener will be assembled according to the following procedure. I. Model #1 Handle and Arbor Assembly

More information

INSTALLATION INSTRUCTIONS FOR BALCO, INC. FLOOR MATS FM2R-(A, C, D) W/O FRAME 4V

INSTALLATION INSTRUCTIONS FOR BALCO, INC. FLOOR MATS FM2R-(A, C, D) W/O FRAME 4V 2626 South Sheridan PO Box 17249 Wichita, Kansas 67217 Phone: (316) 945-9328 Fax: (316) 945-0789 INSTALLATION INSTRUCTIONS FOR BALCO, INC. FLOOR MATS FM2R-(A, C, D) W/O FRAME 4V 2012, Balco, Inc. INSTALLATION

More information

MALTE. the compact and versatile posterior-walker. Instructions for use

MALTE. the compact and versatile posterior-walker. Instructions for use MALTE the compact and versatile posterior-walker Instructions for use Dear Customer, At this point we would like to thank you for placing your trust in our company and for purchasing our product. We ask

More information

User Guide. Tripod. flowtech 75 Tripod. Part No. V

User Guide. Tripod. flowtech 75 Tripod.  Part No. V User Guide Tripod flowtech 75 Tripod Part No. V4150-0001 EN www.vinten.com TM Copyright 2017 All rights reserved. Original Instructions: English All rights reserved throughout the world. No part of this

More information

RUPHIS Blade Clamp. Instruction Manual

RUPHIS Blade Clamp. Instruction Manual RUPHIS Blade Clamp P/N 1006800 NSN 1615-01-562-8156 Instruction Manual AH-64D UH-60A/L UH-60M S-70i S-92 REVISION AUTHORIZATION / RECORD These instructions are primarily for inspection of the RUPHIS Blade

More information

PIONEER LITE PATIO AWNING

PIONEER LITE PATIO AWNING A Manual Crank Operated Awning RV OWNER'S MANUAL Before operating the awning, carefully review the Owner's Manual. The manual contains important safety information, detailed operating instructions, common

More information

User Guide. M9 / M11 Self -Contained Steam Sterilizer. For Models: English Español Français M9 (-033 / -034) M11 (-033 / -034) Style U

User Guide. M9 / M11 Self -Contained Steam Sterilizer. For Models: English Español Français M9 (-033 / -034) M11 (-033 / -034) Style U M9 / M11 Self -Contained Steam Sterilizer English Español Français For Models: M9 (-033 / -034) M11 (-033 / -034) User Guide Style U 003-2546-99 Rev AA3 (10/10/18) Product Information Dealer : Date of

More information

Kontrol Kube Advanced Owners Manual

Kontrol Kube Advanced Owners Manual Mobile Containment. Simplified. TM Kontrol Kube Advanced Owners Manual KONTROL KUBE www.kontrolkube.com 800.343755 1 IMPORTANT SAFETY INFORMATION SAVE THESE INSTRUCTIONS. CAREFULLY READ AND FOLLOW THESE

More information

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles. Directions for Use

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles. Directions for Use ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles Directions for Use Thank you for choosing an ADC Satin Laryngoscope. Device Description and Intended Use A Laryngoscope

More information

PS-10 PS-12D PS-12. Primo Slicer Manual FOR OPERATOR-DO NOT DISCARD

PS-10 PS-12D PS-12. Primo Slicer Manual FOR OPERATOR-DO NOT DISCARD PS-10 PS-12D PS-12 Primo Slicer Manual FOR OPERATOR-DO NOT DISCARD TABLE OF CONTENTS 1. BRIEF INTRODUCTION 2. OPERATION 3. SLICING 4. MAINTENANCE AND CLEANING 5. TROUBLESHOOTING IMPORTANT The operator

More information

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/ Important instructions for use! Please read this information before using the instrument! By purchasing this instrument you have decided for a German high quality product. To ensure the function and safety

More information

SEASONAL ANCHOR SYSTEM FOR PAIR OF PORTABLE SOCCER GOALS

SEASONAL ANCHOR SYSTEM FOR PAIR OF PORTABLE SOCCER GOALS INSTALLATION & USAGE MANUAL SEASONAL ANCHOR SYSTEM FOR PAIR OF PORTABLE SOCCER GOALS No. 00417-040 Set of Four No. 00417-080 Set of Eight ALL PORTABLE SOCCER GOALS MUST BE ANCHORED, TO COMPLY WITH THE

More information

Laboratory Safety. A practical approach.

Laboratory Safety. A practical approach. Laboratory Safety A practical approach. 1 SDS Management All SDS Material is filed in a central location An additional copy is placed in the room where the item is stored Central location files are permanent

More information

Compass Chair E310, E320, E330, E340, & E350. Product Manual E310, E320, E330, E340, & E350

Compass Chair E310, E320, E330, E340, & E350. Product Manual E310, E320, E330, E340, & E350 E310, E320, E330, E340, & E350 Compass Chair E310, E320, E330, E340, & E350 Product Manual Contents Warnings and important information 3 Recommended use 4 Item dimensions 4 Check your order 4 Accessory

More information

Globe Slicer Safety Tips

Globe Slicer Safety Tips Globe Slicer Safety Tips TO AVOID SERIOUS PERSONAL INJURY: NEVER touch this slicer without training and authorization from your supervisor or if you are under 18 years old. Read this instruction manual

More information

OWNER'S MANUAL FREEDOM AWNINGS

OWNER'S MANUAL FREEDOM AWNINGS OWNER'S MANUAL FREEDOM AWNINGS RV PATIO, WINDOW AND OTD AWNINGS Freedom Patio Awning Freedom Window and OtD Awnings Special Note: This manual provides a basic description of the product and the standard

More information

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95) 1612P MODEL 1612P SLICER MODEL 1612P ML-104587 EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO 45374-0001 FORM 19370 (4-95) Installation, Operation, and Care of MODEL 1612P SLICER SAVE THESE INSTRUCTIONS

More information

Sterile Processing Department Solutions CLEANING POWER IN YOUR HANDS INSTRUMENT CLEANING BRUSHES. One Integrated Approach to Healthcare.

Sterile Processing Department Solutions CLEANING POWER IN YOUR HANDS INSTRUMENT CLEANING BRUSHES. One Integrated Approach to Healthcare. Sterile Processing Department Solutions CLEANING POWER IN YOUR HANDS INSTRUMENT CLEANING BRUSHES One Integrated Approach to Healthcare. Hold the cleaning power in your hands Harness the cleaning power

More information

TIME LIMITS AND MAINTENANCE CHECKS

TIME LIMITS AND MAINTENANCE CHECKS TIME LIMITS AND MAINTENANCE CHECKS 1. GENERAL This chapter provides the recommended intervals for the overhaul and replacement of components, and the scheduled and unscheduled maintenance for the airplane.

More information

OWNER'S MANUAL CAMPOUT TABLE OF CONTENTS

OWNER'S MANUAL CAMPOUT TABLE OF CONTENTS OWNER'S MANUAL CAMPOUT RV Before operating the awning, carefully review the Owner's Manual. The manual contains important safety information, detailed operating instructions, common maintenance procedures

More information

EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS.

More information

OREON GROW LIGHT 2.2

OREON GROW LIGHT 2.2 OREON GROW LIGHT 2.2 (GL 600 2.2 XXX) INSTALLATION MANUAL Version: 20180830US/CA IMPORTANT: READ CAREFULLY BEFORE STARTING INSTALLING THE FIXTURE. KEEP FOR FUTURE REFERENCE. MANUAL FOR INSTALLER Thank

More information

Sterilising Department. Buyers Guide.

Sterilising Department. Buyers Guide. 2013 Sterilising Department Buyers Guide www.cheironhealthcare.com.au Index Index Product Index & Ordering Information 2 PAGE Instrument Cleaning Brushes 3-9 - Reusable Endoscope Cleaning Brushes 10 -

More information

1 Pan - 6 Ways to Cook!

1 Pan - 6 Ways to Cook! 1 Pan - 6 Ways to Cook! Broil Bake Sauté Fry Steam Braise To see our entire collection of Copper Chef products and all other available accessories, please visit: CopperChef.com *Only Use Nonmetallic Utensils

More information

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001 BAG-TO-BAG FILTER KIT UN GRN LINE WATER FLOW USER MANUAL Model Number 67252 EPA Est. No 71766-UT-001 EMERGENCY BAG TO BAG FILTER KIT INTRODUCTION Thank you for purchasing the WaterBasics Bag to Bag Emergency

More information

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL 200-BP-CAL-KIT Sphygmomanometer Calibration Kit INSTRUCTION MANUAL Netech Corporation 110 Toledo Street Farmingdale N.Y. 11735 Phone: 631-531-0100 Fax: 631-531-0101 www.netechcorporation.com Sphygmomanometer

More information