TNC 31 Series Threaded Lock RF Connector System Materials Body/Finish Contacts Centre MALE Centre FEMALE Insulator Gasket Crimp Ferrules* *Metal finishes Durability Brass/Nickel Brass/Gold Plated (Au) Phosphor Bronze/Au Delrin/PBT Polyester Silicone Rubber Annealed Copper Nickel (Ni) or Gold (Au) 00 Cycles Crimp/Crimp Straight Plug Electrical Impedance 0 ohm Frequency range 0-11 GHz Voltage 00 VRMS Dielectric withstand 100 VRMS VSWR Straight 1.3 max R/A 1. max Resistance Inner 3 Milliohm max Outer 2 Milliohm max Insulator 000 Megaohm min Part Number: Cable Ferrule Description 31-236-RFX 1 31-2368-RFX RG/U 9/62 Captive Contact 31-83-RFX Plenum 8/141 2 31-838-RFX Plenum 9/62 31-231-RFX RG/U 14/188/316 31-2242-RFX RG/U 19/18 31-839-RFX RG/U 14/188/316 31-840-RFX RG/U 19/18 3 4 T1121x1ND3Gxxx0 Non-Captive Contact Termination Instruction F Pin-to-Pin Contact +/- 1.1 Environmental Temp. range -6 C thru 16 C Shock Consult Representative Humidity Consult Representative Vibration Consult Representative Corrosion Consult Representative Related Information Hand Tools Page W-1 Termination Instr. Page U-3~U-38 Terminology Page U-38 Ferrule 1 Ferrule 2 Ferrule 3 Ferrule 4 Crimp/Crimp Right Angle Plug Part Number: Cable Ferrule Description 31-849-RFX 31-80-RFX RG/U 9/62 31-81-RFX Plenum 8/141 Short Body 6 31-82-RFX Plenum 9/62 RG/U 31-83-RFX 14/19/18/188/316 31-2382-RFX 31-2383-RFX RG/U 9/62 31-84-RFX Plenum 8/141 6 31-8-RFX Plenum 9/62 31-86-RFX RG/U 14/188/316 31-8-RFX RG/U 19/18 Various Straight Plugs Termination Instruction F Part Number: Cable Fig Description 31-98-RFX S/R.08 A:2.2 B:3.0 Solder for Semi-Rigid 31-421-RFX S/R /141 A:2.2 B4.6 8 Cable Termination Instruction S 31-24-RFX RG/U 8 Twist-On for Solid Centre 31-243-RFX RG/U 9 9 Conductor Termination Instruction K 31-98-RFX 31-988-RFX RG/U 9/62 98-RFX 92-RFX RG/U 9/62 10 11 T1112x1ND3Gxx0/T1122x1ND3Gxxx0 T1131x1ND3Gxxx0/T1141x1ND3Gxxx0/T1181A1ND3Gxxx0 Clamp/Solder Captive Contact Termination Instruction I Clamp/Solder Termination Instruction H Short Body Ferrule Ferrule 6 Ferrule Fig 9 Fig 8 Fig 10 Fig 11 ARFA/RF U-18
TNC 31 Series Threaded Lock RF Connector System continued Crimp/Crimp Straight Jack Termination Instruction Ferrule 1/2/4 - E, Ferrule 3 - F T6121x1Nx3Gxxx0 Part Number: Cable Ferrule Description/Insulator 31-234-RFX 31-841-RFX 1 31-23-RFX RG/U 9/62 31-842-RFX 31-843-RFX Plenum 8/141 31-84-RFX 2 31-844-RFX Plenum 9/62 31-846-RFX 31-84-RFX RG/U 14/188/316 3 31-231-RFX RG/U 19/18 31-848-RFX RG/U 14/188/316 4 Pin-to-Pin Contact Crimp/Crimp Bulkhead Jack Termination Instruction Ferrule /6//8/10/11/12 - E, 9/13 - F T6421x1Nx3Gxxx0/T621x1Nx3Gxxx0/T631BxND3Gxxx0/ T661B1NNYL3G0 Part Number: Panel Size/Cable Ferrule Description 31-88-RFX 3.mm 31-2389-RFX 31-89-RFX 6.mm 31-2264-RFX RG/U 9/62 31-860-RFX 3.mm 31-862-RFX 6 31-861-RFX 6.mm 31-863-RFX RG/U 9/62 31-864-RFX 3.mm 31-866-RFX Plenum 8/141 31-86-RFX 6.mm 31-86-RFX Plenum 9/62 31-868-RFX 3.mm 31-80-RFX Plenum 8/141 8 31-869-RFX 6.mm 31-81-RFX Plenum 9/62 31-2318-RFX RG/U 14/188/316 31-224-RFX RG/U 19/18 9 31-82-RFX RG/U 14/188/316 10 Pin-to-Pin Contact 31-83-RFX 3.mm 31-8-RFX 11 31-84-RFX 6.mm 31-86-RFX RG/U 9/62 31-8-RFX 3.mm 31-89-RFX 12 31-88-RFX 6.mm 31-880-RFX RG/U 9/62 31-881-RFX RG/U 14/188/316 31-882-RFX RG/U 19/18 13 31-2301-RFX (L) 3.2mm Solder-Pot 31-889-RFX (L) 6.mm Solder-Pot 31-890-RFX (L) 9.mm Solder-Pot 14 Delrin 31-480-RFX (L) 3.2mm Solder-Pot Various Straight Jacks T6131A1ND3Gxx0/T61A1NT3G0/T1141A1ND3Gxx0 Part Number: Cable Fig Description 31-24-RFX RG/U 8 Twist-On for Solid Centre 31-248-RFX RG/U 9 1 Conductor Termination Instruction K 31-2300-RFX Solder-Pot 16 4-Hole Flange Mount 9600-RFX 31-883-RFX RG/U 9/62 ARFA/RF 1 31-480-RFX is isolated from Ground Clamp/Solder Captive Contact Termination Instruction I Ferrule 1 Ferrule 2 Ferrule 3 Ferrule 4 Fig 1 Ferrule Fig 16 Ferrule6 Ferrule Ferrule 8 Ferrule 9 Ferrule 10 Ferrule 11 Ferrule 12 Ferrule 13 Ferrule 14 Fig 1 U-19
TNC 31 Series Threaded Lock RF Connector System continued PCB Mount Straight Plastic Jack PCB Mount Right Angle Plastic Jack PCB Mount Right Angle Metal Jack T621GxNPP3G0 T622HxNPP3G0 T622HANPP3G0 31-884-RFX White Bulkhead Housing 31-886-10RFX White Bulkhead Housing 31-88-RFX Black Bulkhead Housing 31-88-10RFX Black Bulkhead Housing 31-888-RFX Bulkhead T41A1ND3G0 T41B1ND3G0 T1B1ND3G0 31-891-RFX Includes Gasket 9100-RFX Not Including Gasket 31-892-RFX Metal Mounting Threads Jack-to-Plug TEE Adapter Jack-to-Jack-to-Jack TEE Adapter Jack-to-Jack Straight Adapter T903A1ND3G0 T803A1ND3G0 T01A1ND3G0 900-RFX Delrin 31-98-TRFX Delrin 31-491-RFX Delrin Jack-to-Jack Straight Adapter Plug-to-Plug Straight Adapter Plug-to-Jack Right Angle Adapter T01A2ND3G0 T201A2ND3G0 T02A1ND3G0 31-893-RFX Delrin 31-894-RFX Delrin 912-RFX Delrin ARFA /RF U-20
Termination Instructions Amphenol A Cable Solder (Semi-Rigid) B Cable Solder (Semi-Rigid) C Cable Crimp STEP 3. Solder the BODY to cable as (Avoid excessive heat which may distort dielectric.) STEP 4. Place the RETAINER RING in the groove of BODY, and put the GASKET in the position as STEP. Compress the BODY assembly and assemble the SHELL as catalog CONTACT PIN and solder it as shown STEP 4. Solder the MAIN BODY to cable as shown (avoid excessive heat which may distort dielectric). Then press the INSULATOR into the MAIN BODY until it stops. STEP 3. Slide the HEX NUT and FERRULE onto cable. Then insert the BARREL into braid and dielectric, and slide the FERRULE over braid and crimp it as STEP 4. Slide the REAR INSULATOR against the BARREL. Then insert inner conductor into the CONTACT PIN and solder it as STEP. Slide the FRONT INSULATOR against the REAR INSULATOR. STEP 6. Insert cable and parts into the NUT until it is tight. D Cable Solder (Semi-Rigid) E Cable Crimp/Crimp F Cable Crimp/Crimp STEP 3. Solder inner conductor to the contact pin of MAIN BODY, and solder cable jacket to the MAIN BODY as STEP 4. Screw the NUT into the MAIN BODY until it stops. A crimp tool is necessary to complete the termination. CONTACT PIN and crimp it with the crimp tool as Then slide the FERRULE onto cable. STEP 4. Insert the MAIN BODY into braid and dielectric. STEP. Slide the FERRULE over braid and crimp it with the crimp tool as A crimp tool is necessary to complete RECOMMENDED DIM S in CONTACT PIN and crimp it with the crimp tool the FERRULE onto cable. STEP 4. Insert the MAIN BODY into braid and dielectric. STEP. Slide the FERRULE over braid and crimp it with the crimp tool as U-3
Termination Instructions Amphenol G Cable Crimp/Crimp H Cable Clamp/Solder I Cable Clamp/Solder A crimp tool is necessary to complete the termination. STEP 3. Slide the FERRULE onto cable, then fold back braid wire and slide the SPACER and INSULATOR onto dielectric as STEP 4. Insert inner conductor into the CONTACT and crimp it with the crimp tool as STEP. Push cable and parts into the MAIN BODY until it stops. Then slide the FERRULE over braid wire and against the MAIN BODY and crimp it with the crimp tool as CONTACT and solder it as Then slide the HEX NUT, WASHER, and GASKET onto cable. STEP 4. Place the BRAID CLAMP over braid and push back against cable jacket. Fold back braid wire as STEP. Insert cable and parts into the NUT until it is tightened. J Cable Wedge Compression K Cable Twist-On L Cable Clamp STEP 3. Slide the HEX NUT, WASHER, and GASKET onto cable one by one. STEP 4. Place the BRAID CLAMP over braid and push back against cable jacket. Fold back braid wire as shown, and slide the RING and REAR INSULATOR against the BRAID CLAMP. Then insert inner conductor into the CONTACT PIN and solder it. STEP. Insert cable and parts into the NUT until it is tightened. STEP 1. STEP 2. STEP 3. STEP 4. dielectric, braid, and jacket as per "RECOMMENDED CABLE STRINPPING DIM'S " in STEP 3. Slide the HEX NUT onto cable, then insert the CONTACT ASSEMBLY under braid and jacket. STEP 4. Insert cable and parts into the NUT until it is tight. STEP 1. The connector is STEP 3. Twist braid in a clockwise direction so that at least 0.8mm of dielectric is bared, and braid is left flat. STEP 4. Insert inner conductor into the back end of connector gently, and feed it into the contact. STEP. Push and screw the connector onto cable in a clockwise direction until it stops. STEP 1. STEP 2. STEP 3. STEP 4. STEP. STEP 6. All parts of the connector are Strip the cable inner conductor, STRIPPING DIM S in Then slide the NUT, WASHER, and GASKET onto cable. Place the BRAID CLAMP over braid and push back against cable jacket. Fold back braid wire as Slide the RING against the BRAID CLAMP. Then insert inner conductor into the CONTACT PINS and solder them. Insert the CONTACT PINs into the INSULATOR until the INSULATOR is against the TOP HAT. Insert cable and parts into the MAIN BODY, aligning slot of the INSULATOR with key in the MAIN BODY. Then screw the NUT until it is tight. U-36