Instructions for Use: Duodenoscope Sampling Kit

Similar documents
Cleaning & Disinfection of Eickview Videoendoscopes

SOURCE: Infection Prevention & Control (IPC)

LESSON ASSIGNMENT. Surgical Asepsis and Sterile Technique. After completing this lesson, you should be able to:

Home Care for Your Gravity Fluid Drain

How to Use Your Implanted Venous Port

Caring for Your Chest Tube and Pneumostat Chest Drain Valve

NNIN Nanotechnology Education

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

LBH18BPK. Instruction Sheet

Mixing Your Alpha-1 Therapy Aralast NP

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

Cultures, Specimen Collection for

A Pre-Paid Return Label is included (optional) *Call for pick up no later than the above return date to avoid additional rental fees

Giving Tube Feedings at Home (by Gravity)

S E L E C T I O N. Abdominal Crunch. User manual

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System

Field Situation - How to safely collect oral swabs (saliva) from deceased patients suspected to be infected with Ebola

Installation and Maintenance Manual

Performing Hand Hygiene Using an Alcohol-Based Handrub

WARMING BLANKETS INSTRUCTIONS FOR USE

ENDO CARRY-ON. Procedure Kit

How to safely collect oral swabs (saliva) from deceased patients suspected to be infected with Ebola or Marburg

How to safely collect blood samples by phlebotomy from patients suspected to be infected with Ebola or Marburg

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

TAKE EVERY PRECAUTION TO PREVENT CONTACT WITH SKIN OR HAIR!!!

Instructions for Use A-dec Quick-Disconnect Syringes

Minor Procedure Kits. Stock and Customized Kits

BRJK11F2, BTJK11F2, BRJK07F2, BTJK07F2, kit

Procedure Guidelines Protocol Title:

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

Instrument Care and Handling Guide

Pediatric Lower Body Warming Blanket Model B203 Instructions for Use

Gas Go Anywhere /23/01

TOILET and RELIEF TUBE SERVICING

ELECTRIC KNIFE SHARPENER User Guide

OPERATOR INSTRUCTION MANUAL INCLUDING REPAIR PARTS FOR MODULAR GENERAL PURPOSE TENT SYSTEM (MGPTS) TYPE I

User s Manual Trampoline 8

14' x 32' x 12' Round Top Round Style Shelter Assembly Instructions

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

How to Change Your Medicine Bag

FORM (Apr. 2006)

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

2522 and 2523 Fiber Optic Splice Organizer Tray

Adult Diaper. Our Adult Diapers are Ultra Absorbent with 10 SAP for best convenience to patients and one of the best available in India.

CUSTOM PROCEDURAL TRAYS

Replacement of External Pipe Assembly on PFS December 21, 2014

INSTALLATION INSTRUCTIONS

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

Adult Diapers. Anti Bacteria Anti Odour Anti Allergy Wetness Indicator Extra Absorbent Leak Proof

INSTRUCTIONS FOR USE (IFU)

HZS Field Spectroscopy Kit

OWNER S MANUAL. IMPORTANT: This instruction manual contains important information necessary for the proper assembly and safe use of the appliance.

Chemical Spill Response Guide

Instruction Manual please read before use

Laboratory Safety. A practical approach.

Preparation. BEDRUG, INC. n 635 Old Hickory Blvd, Old Hickory, TN n n bedrug.com

WARNING: IMPROPER INSTALLATION WILL RESULT IN LINER FLYING OUT OF THE TRUCK. FOLLOW INSTRUCTIONS EXACTLY

Rigging a portable loop antenna

SIMPLIFIED TECHNIQUE FOR THE COLLECTION OF RABIES DIAGNOSTIC MATERIAL FROM ANIMALS

Instructions for Use Repatha (ri-path-a) (evolocumab) Single-Use Prefilled SureClick Autoinjector. Guide to parts

Instructions for Use AIMOVIG TM (AIM-oh-vig) (erenumab-aooe) Injection, For Subcutaneous Use Single-Dose Prefilled SureClick Autoinjector

INSTALLATION INSTRUCTIONS

Blue Series Hot Melt Hose with RediFlext II Hanger System

User Guide. Tripod. flowtech 75 Tripod. Part No. V

Model 205 Fireview Maintenance Kit

SECTION 1. Endoscope Transport and Protection. SECTION 2. Manual Cleaning Bedside. SECTION 3. Manual Cleaning Decontamination

Heyinovo. Disposable Biopsy Valves User Manual. Technical Publications. Document No: WI-RD-13-M07, Rev. B

APPENDIX KING VISION VIDEO LARYNGOSCOPE

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

Instruction Manual please read before use

INFRARED BURNER KIT INSTRUCTIONS

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

Thoracic Drainage - Pleural Puncture - Accessories

Esophageal Dilatation Systems

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

OW LEE CASUAL FIRESIDE Q&A

#6 Spill and Accident Procedures

Sterile Processing Department Solutions CLEANING POWER IN YOUR HANDS INSTRUMENT CLEANING BRUSHES. One Integrated Approach to Healthcare.

INSTALLATION INSTRUCTIONS

Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves

COMBI CRATE MODEL NO: 7000/7001/7002/7003

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

Innovative New Products

For the diagnosis of Hirschsprung s Disease

An Improved Pedestal To A Version One Worksurface

Operating Instructions

Workplace Eyewash & First Aid Point

ASSEMBLY INSTRUCTIONS

Kontrol Kube Advanced Owners Manual

JOINING MULLION (DIRECT MULL) ASSEMBLY INSTRUCTIONS FOR 3-WAY OR 4-WAY JOINTS FOR IMPERVIA AWNING, CASEMENT AND LARGE AWNING

Maintaining the Pretium FBC-015 Cleaver

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Made of polypropylene

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

TECHNICAL INFORMATION Primer Residue Collection Kit for SEM, ICP-MS and AAA Catalog No. GRA100

User Guide. Tripod. flowtech 75 Tripod. Part No. V

INFRARED BURNER KIT INSTRUCTIONS

Transcription:

Instructions for Use: Duodenoscope Sampling Kit Brand Name of Product Generic Name of Product Product Code Number(s) Intended Use Duodenoscope Sampling Kit Endoscope sampling and culturing kit CK-250, CK-374 The Duodenoscope Sampling Kit provides items to collect a sample from a duodenoscope and ship to Nelson Labs for further testing for presence of microorganisms. If present, the organisms will be quantified, and 2 organisms will be identified. Additional identifications, if needed/desired, can be conducted for additional purchase. This test does not assure the suitability of the flexible endoscope for patient-use. For microbial surveillance testing of duodenoscopes Range of Applications for Product Key Specifications of Product 1. Sample collection container 2. Sterile scissors 3. Thermometer 4. Shipping box (shipping label included) 5. 2 Ice packs 6. 2 30 ml syringes 7. 1 5 ml syringe 8. Labels 9. Instrument channel brush (240cm long) 10. Distal tip brush 11. Alcohol wipe 12. Two 1 ml pipettes 13. Sterile Swab 14. DE broth 15. 1 Absorbent pad 16. 1 Leak resistant ziplock bag 17. 1 Packing tape Shipping Conditions & Requirements Storage Conditions Packaging Conditions Shelf Life Shipping & Storage 1. Sample must be shipped the same day it is captured. 2. The included shipping label is for weekday, next day delivery. 3. This sample needs to be taken and shipped Monday - Thursday to Nelson Labs. Ice packs and thermometer must be frozen until prior to use. Follow instructions below for proper packaging. 6 months Description of Use (s) Preparation for Use Instructions for Using Product Collect a sample and send to Nelson Labs for further testing for presence of microorganisms. If present, the organisms will be quantified and up to 2 organisms will be identified. 1. Upon receiving the kit, remove the ice packs that are around the DE Broth. 2. Remove the thermometer. 3. Place the ice packs and temperature monitor in a freezer for a minimum of 8 hours before use. Ensure the ice packs are laid flat. 4. Store the DE Broth in the refrigerator (2-8 ). 5. When ready to test, enter on the provided label the date, personnel initials, model and serial numbers of the scope. 6. Supplies to be provided by the facility include: o Disinfecting wipe o 1 Sterile pad/ drape (large enough to have an endoscope to be placed flat on it for testing). o 45 ml of Sterile water o Appropriate PPE for 2 people: fluid resistant sterile gown, fluid resistant face and eye protection, sterile gloves, bouffant caps for hair. o A countertop or table long enough to lay the scope out. o 10x Magnifier 1

o Sterile elevator wire channel washing/flushing/cleaning tube adapter 7. Prepare test area: o Wipe down the counter with the disinfecting wipe (reference the IFU for the wipe). o Place a sterile pad/drape on counter/surface. o Don PPE 8. Sampling Preparation: o Allow enough space for the flexible endoscope that is to be tested to lie flat on the sterile pad/drape o Place duodenoscope flat on the pad/drape o Using a 10x magnifier, perform a visual inspection of the distal end for debris or other concerns. If debris is present notify appropriate staff per facility policy. o 2 people will be needed to do the sampling: A Sampler and a Facilitator: - The sampler maintains aseptic handling and conducts brushing steps. - The facilitator opens packages and handles unsampled portions of the endoscope. Diagrams (drawings, pictures) Duodenoscope Diagram Photos: 2 3 9 2

10 11 12 13 14 15 3

16 17 18 19A 19B 20 21 22 23 4

24 25 26 27 28 29A 5

29B 30 31 48 49 50 51A 51B 52 54 55 56A 6

56B 58 59 60 61 62 65 66 69 7

70 71A 71B 72 74 75 8

76 78 80 Steps for Use of Product Distal Cap Seam Sampling 81 83 84 1. Facilitator: Open a sterile alcohol wipe package. 2. Sampler: Remove sterile alcohol wipe from package. 3. Sampler: Wipe exterior of distal end with alcohol wipe. 4. Ensure that the elevator recess and the seams near the elevator recess are not exposed to the alcohol during wiping (refer to Figure below). 5. Sampler: Wipe away from the elevator recess, taking care to avoid the elevator lever, recess, and the seams between the distal cap and distal end. 6. Allow the alcohol to dry. 7. Figure below: Close-up of duodenoscope distal end, and location and direction of alcohol wiping (white arrows) of the exterior of the distal end, and location of seams to swab for sampling (in red). The seams between the distal cap and the distal end may be of variable design with different models of duodenoscopes, and may not extend completely around the elevator recess. 9

8. 9. Facilitator: Open the sterile swab package. 10. Facilitator: Open the sterile water container (loosely place the cap back on the sterile water container after the sampler has moistened the swab in sterile water. 11. Sampler: Remove the sterile swab from the package. 12. Sampler: Moisten the sterile swab in sterile water. This may be done by dipping the swab tip in the water. 13. Sampler: Swab along the seam between the distal cap and the distal end (refer to Figure 13 above). The distal cap is frequently a plastic material, whereas the distal end is frequently made of metal. 14. Facilitator: Open the sample collection container and hold the container. 15. Sampler breaks off the tip of the sterile swab into the sample collection container. The provided swab has a breakpoint for breaking off the tip. 16. Facilitator: Close the sample collection container. Elevator Recess Sampling For Olympus and Fujifilm Duodenoscopes Elevator recess sampling method for a duodenoscope with a fixed distal cap with no hole (Olympus and Fujifilm): 17. Facilitator: Open the package for the sterile pipette. 18. Facilitator: Open the sterile water container (loosely place the cap back on the sterile water container after the sampler has withdrawn sterile water). 19. Sampler: Remove the sterile pipette from the package and fill with 1 ml of fresh sterile water. 20. Facilitator: Lower the elevator lever. 21. Sampler: While holding the distal end so that it is parallel to or lying flat on the sterile drape or pad, apply 1 ml of sterile water into the elevator recess with the sterile pipette. 22. Sampler: Use the same pipette to draw that fluid up and down into pipette five times. 23. Sampler suctions the fluid into the pipette while facilitator raises the elevator lever. 24. Sampler repeats the previous two steps by applying the fluid into the recess five times. 25. Facilitator: Open the sample collection container (close the container after the sampler has added the sample). 10

26. Sampler: Use the same pipette to remove fluid from the elevator recess and transfer the fluid to the sample collection container. 27. Facilitator: Open the package for the sterile elevator cleaning brush. 28. Facilitator: Open the sterile water container (loosely place the cap back on the sterile water container after the sampler has moistened the brush in sterile water). 29. Sampler: Remove the sterile elevator cleaning brush from the packaging and moisten in fresh, sterile water. This may be done dipping the brush head in the water. 30. Sampler brushes the elevator recess while facilitator raises and lowers the elevator. 31. Sampler puts the brush in the sampling container. 32. With a new sterile pipette, repeat the above sampling steps (steps 17-26) For Pentax Duodenoscopes Elevator recess sampling for a duodenoscope with a hole in the distal cap or with a removable distal cap (PENTAX: 33. Facilitator: Open the package for the sterile pipette. 34. Facilitator: Open the sterile water container (loosely place the cap back on the sterile water container after the sampler has withdrawn sterile water). 35. Sampler: Remove the sterile pipette from the package and fill with 1 ml of fresh sterile water. 36. Facilitator: Lower the elevator lever. 37. While sampler holds the distal end so that it is parallel to the draped counter surface, facilitator places the open sample collection container underneath the distal end of the duodenoscope. 38. Sampler applies 1 ml of sterile water into the elevator recess with the sterile pipette and allows that volume to drain into the sample collection container by gravity. 39. Sampler applies a second 1 ml volume of sterile water to the elevator recess, capturing the volume as it exits the elevator recess or drains through the hole in the back of the cavity and into the sample collection container. 40. Facilitator raises the elevator lever. 41. Sampler repeats the previous two steps by applying 1 ml of sterile water to the elevator recess twice, allowing the extraction fluid to drain from the cavity by gravity and into the sample collection container. 42. Facilitator opens the package for the sterile elevator cleaning brush. 43. Sampler removes the sterile elevator cleaning brush from the packaging. 44. Sampler moistens the sterile elevator sampling brush in fresh, sterile water. 45. Sampler brushes the elevator recess while facilitator raises and lowers the elevator. 46. Sampler puts the brush in the sampling container. 47. With a new sterile pipette, repeat steps the above sampling steps (steps 33-41) Elevator Wire Channel Sampling (only for duodenoscopes with an open elevator wire channel) 11

48. Facilitator: Open the packaging for the elevator wire channel washing/flushing/cleaning tube adapter. 49. Sampler removes the elevator wire channel washing/flushing/cleaning tube adapter and attaches it to the elevator wire channel port. 50. Facilitator: Open the packaging for the sterile 5 ml syringe. 51. Sampler: Remove the sterile 5 ml syringe from the packaging and draw up 3 ml of sterile water into the syringe. 52. Sampler: Attach the syringe to the elevator wire channel washing/flushing/cleaning tube adapter. 53. Facilitator positions the duodenoscope so that it is nearly vertical. 54. Facilitator holds the control handle of the duodenoscope and the syringe (attached to the elevator wire channel adapter) while sampler holds the distal end. Having the facilitator stand on a step stool while holding the control handle may assist in keeping the duodenoscope vertical. 55. Sampler ensures that the sample collection container is at the distal end to allow for collection of the liquid 56. Facilitator slowly flushes 3 ml of sterile water into the elevator wire channel and the sampler captures the fluid at the distal end. 57. While the facilitator continues to hold the duodenoscope, the sampler places the sample collection container on the drape. 58. Sampler then removes the syringe from the elevator wire channel adapter, fills the syringe with air, and reattaches the syringe to the elevator wire channel adapter. 59. Sampler takes the sample collection container and positions it under the distal end of the duodenoscope. 60. Facilitator flushes 5 ml of air into the elevator wire channel to evacuate the channel of fluid water. 61. Sampler continues to ensure that the sample collection container is at the distal end to allow collection of the fluid. 62. After the air has been flushed into the channel, the sampler may cap the sample collection container and place it on the sterile drape. 63. Facilitator removes the elevator wire channel washing/flushing/cleaning tube/adapter from the elevator wire channel port and places the duodenoscope on the sterile drape. Instrument Channel Sampling 64. Facilitator opens the packages for two 30 ml syringes. 65. Sampler removes each syringe from the packaging. 66. Facilitator opens the sterile water bottle while sampler fills each syringe with 20 ml of water. 67. Sampler places the syringes on the sterile drape. 68. Facilitator elevates the control handle of the duodenoscope so that the duodenoscope is nearly vertical. 69. Sampler hands a syringe to the facilitator and holds the distal end over the sample collection container. 70. Facilitator flushes the instrument channel with 20 ml of sterile water, which sampler captures in the sample collection container. 12

71. Facilitator fills the syringe with air and flushes air into the instrument channel. Any residual fluid is captured in the sample collection container. 72. After the air has been flushed into the channel, the sampler may cap the sample collection container and place it on the sterile drape. 73. Facilitator places the duodenoscope on the sterile drape. 74. Facilitator opens sterile scissors package. 75. Sampler removes the sterile instrument channel brush from the packaging. 76. Facilitator holds the duodenoscope vertically while sampler inserts the sterile instrument channel brush into the biopsy port. 77. Once the brush has been inserted about 3 inches, the sampler transfers the brush handle to the facilitator. 78. Sampler holds the collection container at the distal end to capture any fluid that exits the channel with the brush, making sure not to touch the distal end. 79. Facilitator continues to push the brush through the instrument channel. 80. After the brush head exits the distal tip, the sampler uses sterile scissors to cut the entire head of the bristled portion of the brush while keeping it in the container and places it into the sample collection container. 81. The remainder of the brush should be pulled out of the duodenoscope from the biopsy port. 82. Repeat the above sampling steps (steps 69-73) for an additional fluid flush to be added to the collection container. Addition of neutralizer solution and transport preparation: 83. Add the provided DE broth to the sample. - Do not allow the duodenoscope to contact the neutralizer solution in the sample container. - Accidental immersion of any part of the duodenoscope distal end into the neutralizer solution necessitates complete reprocessing. - DE broth is added to facilitate outgrowth of microbes that have been potentially damaged by the reprocessing process. 84. Tightly close lid of sample container by pressing cap from the hinge location and pushing forward, it should securely snap shut. Close tab then pull the tie through round hole on post and lock vial. Sampling of additional channels Healthcare facilities may also choose to sample additional channels in duodenoscopes, such as the air/water and suction channels by flushing those channels with sampling fluid (sterile water). The volume of flush solution will vary depending on the channel dimensions, and endoscope model-specific connectors may be required for flushing different channels. 13

Package for Shipment 1. Adhere the label to the sample collection container. Figure 1 Fig. 1 2. Ensure the label is properly filled out. 3. Wrap the absorbent material around the sample container. Figure 2 Fig. 2 4. Place the sample container in the provided leak resistant ziplock bag. Figure 3 14

Fig. 3 5. Place the above packaging in the provided cubed foam insert. Figure 4 Fig. 4 6. Place one frozen ice pack in the bottom of the shipping box. Figure 5 Fig 5 7. Place the foam with sample collection container on top of the ice pack. Press the container down so that the bottom of the container is in contact with the frozen ice pack. Figure 6 15

Fig 6 8. Place the other frozen ice pack on top of the sample container. Figure 7 Fig. 7 9. Fill out the provided sample submission form. Figure 8 Fig. 8 10. Insert the sample submission form into the envelope attached to the top of the insulated foam lid. Figure 9 16

Fig. 9 11. Activate the thermometer by pressing in the clear button. Figure 10 Fig. 10 12. Adhere the thermometer to the underside of the insulated foam lid. Figure 11 Fig. 11 13. Close the lid of the shipping box with the included packing tape. Figure 12 Fig. 12 17

14. Immediately take to the shipping department or a Fedex pick-up location for shipment to Nelson Labs for next day morning delivery (prepaid shipping label is already on the shipping box). 15. Follow the endoscope manufacturer s IFU for high level disinfection and preparation for storage (including drying steps). Interpretation of Results Contraindicat ions of Test Results Documentatio n Special Warnings and Cautions Disposal This test should be shipped Monday - Thursday OVERNIGHT to Nelson Labs. Point of Use Preparation for Decontamination Disassembly Instructions Cleaning Manual Cleaning Automated Disinfection Drying Maintenance, Inspection, and Testing Reassembly Instructions Packaging Sterilization Storage Additional Information Reprocessing Instructions Related Healthmark Products EndoCheck for Blood, EndoCheck for Protein, ChannelCheck, FlexiCheck Other Product Support Documents FDA s Duodenoscope Surveillance Sampling and Culturing Protocols, 2018 Reference Documents ProFormance Brochure, ProFormance Price List Customer Service Contact Healthmark Industries Company, Inc 33671 Doreka Fraser, MI 48026 1-586-774-7600 healthmark@hmark.com hmark.com 2018-08-28 Ralph J Basile 18