Preparation and Installation of the (VPC) Flat Circular Vent Panel

Similar documents
Preparation and Installation of the (VPR) and (VPS) Rectangular and Square Vent Panels

VENT PANELS. Continental s vent panels provide the following benefits:

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

2100 Series Series Emergency Pressure Relief Vent and Manhole Cover. North America Only. Table of Contents. Introduction. Scope of the Manual

Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves

Operating Instructions

Installation Guide Cable

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

Gas Conversion Kits and Instructions

TCWS54 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

DeZURIK AM-SERIES MANUAL GEAR ACTUATOR USED ON BUTTERFLY VALVES

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

Advantage Plus TIM-3600 Series Reel

Installation and User s Manual 12 x 10 MOTORIZED AWNING

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

LDR Brachytherapy Seed Sterilization and Sorting Tray

Hose Reel Series L701/G701

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

Urea/Adblue Hose Reel

4A1-114/114KR & 4A1-2 MANUAL TENSIONERS

300 ft. 5/8 Hose wagon

TANK MONITOR MODEL # (12V DC) (24V DC) (32V DC) OPERATION AND INSTALLATION INSTRUCTIONS

Model 205 Fireview Maintenance Kit

Two Piece Low Torque Kelly Valve

Unshielded Fluid Hose Kit


USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

Blue Series Hot Melt Hose with RediFlext II Hanger System

MOTORIZED FOLDING CAMPER WINCH

Solar Power Shade INSTRUCTION MANUAL

READ ME! IMPORTANT WARNING! ENG. Quick Release Tent Mount Kit

front runner READ ME! IMPORTANT WARNING! ENG Foxwing Awning Brackets

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING

NEWMAR SERVICE SCHOOL

Item #: BTOT Assembly Instructions

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS. MD25-( ) Series Airspeed Indicator

BILLY GOAT KV HOSE KIT (P/N ) PURPOSE: To allow for vacuuming in hard to reach places.

Style # Laguna Propane Tank Cover Owner s Manual

TCWS.54NG03C2 BLACK DIAMOND BURNER KIT INSTRUCTIONS

VALORE SEVEN. Serial Number. Pacific) Version No.:V

Manual Awning. Assembly Instructions. Product No Toll-free:

MOTORIZED OR MANUAL LATERAL ARM BOX AWNING. Product Overview... 1 Component Checklist... 2

* * KR54-F, KR9854 & KR9954 Installation Instructions. Read All Warnings Before Starting Installation! Index:

INSTRUCTIONS INSTALLATION UNIVERSAL SERIES PATIO AWNING HARDWARE , , ,

accidents which arise due to non-observance of these instructions and the safety information herein. CAUTION:

Installation and Maintenance Manual

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

TASK FORCE TIPS * *

MAX Series 9514 OPERATOR S MANUAL

SPIRAL SLICER Instruction Manual Model #5280 & 5280M. Part No Revised Feb. 2010

Step by Step Set Up Guide

TC36 SEE-THRU CHALET BURNER KIT INSTRUCTIONS

Cordless Electric Teakettle. Model 685

Safety instructions and warnings Package contents and parts Tool requirements Product features... 5

Retractable Lance Instructions

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

PRODUCT MANUAL - M096

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

Eaton ET Hydraulic Hose Saw INSTRUCTION MANUAL

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

TC42 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

7. Do not dispose of the packaging immediately.the package insert contains a template for mounting the slide bar A/Rev01 G1/2" G1/2" G1/2"

All Restoration Hardware beds are designed to meet the highest safety standards and comply with all U.S. and Canadian beds and beds regulations.

EEZI - AWN series 1000 / 2000 Awning bracket

OPERATOR INSTRUCTION MANUAL INCLUDING REPAIR PARTS FOR MODULAR GENERAL PURPOSE TENT SYSTEM (MGPTS) TYPE I

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

ROCKING HAMMOCK GD-600. Model GD-600. Retain This Manual for Reference OWNER'S MANUAL

Sealing and terminating Wrexham Mineral Cables

User s Manual Trampoline 8

1000M MANUAL Signature Series Slicer OPERATORS MANUAL

AUTO REWIND HOSE REEL WITH 50 FOOT HOSE. Model 46320

Important! Read all of these instructions before assembling or riding the glider. For questions or help please call Glide Bikes at

AFC-50 Automatic French Fry Cutter Instruction Manual

SUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP

Cloze Control Installation Instructions I001 June 2016

Agilent Ultimate Union Kits (G and G )

FILTERED FAN PACKAGES

13ft x10ft Roof Style Gazebo

RH BABY&CHILD AVALON TWIN OVER TWIN BUNK BED INSTRUCTIONS

Parts Catalog T7/T71/T73 M40000/M40001/M40003

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

Antenna Tower Positioning System

Kontrol Kube Advanced Owners Manual

MOTORIZED FOLDING CAMPER WINCH

Safety instructions and warnings Package contents and parts Tool requirements Product features... 4

ALPINE SLIDEOUT COVER

Brooks Fire Pit Table. Installation Instructions for Brooks Fire Pit Table BRK-1224

The Wave. Installation Instructions for WV-56 Table

Transcription:

GEP-6031 Rev. T 102335 Ref. I.D.: 8040 Preparation and Installation of the (VPC) Flat Circular Vent Panel WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING VENT PANEL. THESE INSTRUCTIONS DO NOT PURPORT TO ADDRESS ALL OF THE SAFETY FACTORS ASSOCIATED WITH THE VENT PANEL S USE IN SERVICE. IT IS THE RESPONSIBILITY OF THE USER TO ESTABLISH APPROPRIATE SAFETY, HEALTH, AND TRAINING MEASURES FOR THEIR PERSONNEL INSTALLING, SERVICING, OR WORKING IN AN AREA WHERE VENT PANEL ASSEMBLIES ARE IN USE. SERVICE AND/OR MAINTENANCE ON OR AROUND THE VENT PANEL DEVICE MUST NOT BE PERFORMED WHILE THE DEVICE IS SUBJECTED TO OPERATING PRESSURES AND/OR TEMPERATURES. IT IS THE USER S SOLE RESPONSIBILITY FOR DESIGN AND PLACEMENT OF VENT PANELS WITHIN THEIR FACILITY AND UPON THE EQUIPMENT UPON WHICH THE VENT PANEL OF USER S SELECTION IS TO BE LOCATED. IT IS USER S SOLE RESPONSIBILITY FOR THE DESIGN OF ADEQUATE VENTING AND INSTALLATION OF ADEQUATE VENT PIPING OR DIRECTIONAL FLOW AFTER RUPTURE OCCURS WITH THE VENT PANEL AS INTENDED. WHEN SIZE IS SPECIFIED, CONTINENTAL DISC CORPORATION ASSUMES THAT ADEQUATE PROVISIONS HAVE BEEN MADE BY PURCHASER FOR PROPER VENTING OF A SYSTEM TO RELIEVE THE SPECIFIC PRESSURE. LOCATE VENT PANEL WHERE PEOPLE OR PROPERTY WILL NOT BE EXPOSED TO THE SYSTEM DISCHARGE IN CASE OF RUPTURE. VENT TOXIC OR FLAMMABLE FUMES OR LIQUIDS TO A SAFE LOCATION TO PREVENT PERSONAL INJURY OR PROPERTY DAMAGE. IT IS THE USER S SOLE RESPONSIBILITY TO SPECIFY THE BURST PRESSURE RATING OF A VENT PANEL AT A COINCIDENT TEMPERATURE AT WHICH THE VENT PANEL IS TO BE USED. A VENT PANEL IS A TEMPERATURE SENSITIVE DEVICE. THE BURST PRESSURE OF THE VENT PANEL IS DIRECTLY AFFECTED BY ITS EXPOSURE TO THE COINCIDENT TEMPERATURE. GENERALLY, AS THE TEMPERATURE AT THE VENT PANEL INCREASES, THE BURST PRESSURE DECREASES; INVERSELY, AS THE TEMPERATURE AT THE VENT PANEL DECREASES, THE BURST PRESSURE MAY INCREASE. FAILURE TO PROPERLY UTILIZE A VENT PANEL AT THE SPECIFIED COINCIDENT TEMPERATURE COULD CAUSE PREMATURE FAILURE OR OVERPRESSURIZATION OF A SYSTEM. THE INSTANTANEOUS RELEASE OF PRESSURE FROM THE VENT PANEL CAN CREATE VIOLENT NOISES DUE TO THE DISCHARGE AT SONIC VELOCITY. IT IS THE USER S SOLE RESPONSIBILITY TO PROTECT AGAINST HEARING DAMAGE TO ANY BYSTANDERS. VENT PANELS AND TAGS ARE MADE OF METAL FOILS OF VARYING THICKNESS. THE METAL EDGES MAY BE SHARP. PERSONNEL INSTALLING OR EXAMINING THE VENT PANELS SHOULD PROTECT AGAINST CUTS OR INJURY WHEN HANDLING THE VENT PANEL. DO NOT LIFT A VENT PANEL BY ITS ATTACHED TAG. PARTICLES MAY BE DISCHARGED WHEN THE VENT PANEL RUPTURES. THESE PARTICLES MAY BE PART OF THE VENT PANEL ITSELF, OR OTHER ENVIRONMENTAL MATTER IN THE SYSTEM. IT IS THE USER S SOLE RESPONSIBILITY TO ASSURE THAT THESE PARTICLES ARE DIRECTED TO A SAFE AREA TO PREVENT PERSONAL INJURY OR PROPERTY DAMAGE. THERE IS NO GUARANTEE OF VENT PANEL LIFE. SUCH LIFE SPAN IS AFFECTED BY CORROSION, CREEP AND FATIGUE, AND PHYSICAL DAMAGE. THESE CONDITIONS WILL DERATE THE VENT PANEL TO A LOWER SET PRESSURE. THE CUSTOMER AND/OR USER SHOULD BE PREPARED TO HANDLE PREMATURE FAILURE OF THE VENT PANEL. THE MEDIA OR OTHER ENVIRONMENTAL CONDITIONS SHOULD NOT ALLOW ANY BUILDUP OR SOLIDIFICATION OF MEDIA TO OCCUR ON A VENT PANEL. THIS MAY INCREASE THE PRESSURE SETTING OF THE VENT PANEL. CUSTOMER AND/OR ITS INSTALLER SHALL BE SOLELY RESPONSIBLE FOR THE PROPER INSTALLATION OF SELLER S HOLDERS AND VENT PANELS INTO A SYSTEM. CUSTOMER AND/OR ITS INSTALLER SHALL BE SOLELY RESPONSIBLE FOR IMPROPER INSTALLATION AND PHYSICAL DAMAGE RESULTING THEREFROM, INCLUDING BUT NOT LIMITED TO, DAMAGE RESULTING FROM LEAKAGE, IMPROPER TORQUING OR SEATING OF A VENT PANEL OR FAILURE TO FOLLOW INSTALLATION INSTRUCTIONS WHERE PROVIDED. VENT PANELS ARE PRECISION SAFETY DEVICES AND MUST BE INSTALLED PROPERLY. VENT PANELS MUST BE INSTALLED BY TRAINED, KNOWLEDGEABLE INSTALLERS AND ONLY WITHIN ENVIRONMENTS SUITABLE AND APPROPRIATE FOR A VENT PANEL. CARE MUST BE USED IN A FACILITY'S DESIGN TO PROTECT BOTH THE VENT PANEL FROM INADVERTENT DAMAGE WHICH COULD CAUSE ITS PREMATURE RELEASE AND TO PROTECT INDIVIDUALS EXPOSED TO HAZARDS CREATED BY SUCH SUDDEN RELEASE. PROPER INSTALLATION OF A VENT PANEL IS CRITICAL TO PERFORMANCE AND TO SAFETY. FAILURE TO PROVIDE PROPER SEATING OF A VENT PANEL MAY AFFECT VENT PANEL PERFORMANCE, BURST PRESSURE ACCURACY AND MAY RESULT IN ITS PREMATURE FAILURE.

I. Safety Precautions Before Installation 1. The Vent Panel is a precision instrument and must be handled with extreme care. Vent panels should be installed only by qualified personnel familiar with vent panel practices. 2. Do not install the vent panel if there is any damage evident. A damaged vent panel is any vent panel with visible nicks or dents. 3. The vent panel must be installed with the labeled side facing the venting direction. 4. Continental Disc Corporation does not recommend reinstalling a vent panel that has been removed from the vent frame as reinstallation may adversely affect the joint sealing capabilities and/or performance of the vent panel. 5. See vent panel label to verify set pressure, operating temperature, and all other operating parameters. Figure 'A' NUT WASHER VENT FRAME OUTLET DENT PROTECTOR B.D.I. ASSEMBLY II. Preparation of Vent Frames for Installation New Installation Clean all foreign material from the vent panel sealing area of both the vent frame inlet and outlet. Replacement Installation 1. If the Burst Disc Indicator (B.D.I. ) Alarm System is used, disconnect the alarm strip from the monitor by unplugging the B.D.I. connector from the lead wire connector. NOTE: THE B.D.I. ASSEMBLY IS TYPICALLY SUPPLIED WITH A CONNECTOR; HOWEVER, AN OPTIONAL DESIGN WITHOUT A CONNECTOR MAY BE SUPPLIED UPON REQUEST. VENT PANEL VACUUM SUPPORT GASKET VENT FRAME INLET BOLT 2. Disassemble the vent frame by removing all assembly bolts, nuts, and washers. Lift the outlet frame up and set aside; then remove the burst vent panel. 3. Clean the vent panel sealing area of both the vent frame inlet and outlet. These surfaces must be completely clean and free of all rust, corrosion, and foreign material to ensure a proper seal. Use of solvents, steel wool, or fine emery cloth is permissible. Do not remachine. Do not use scraper or abrasives. STRAIN RELIEF CLIP FLOW DIRECTION Figure 'B' 4. Inspect the vent panel sealing area for nicks, scratches, or pitting. If any of these conditions are present, consult the factory for repair. 5. Remove any adhered gasket material from previous installation. III. Assembly of the Vent Panel and Vent Frame (See Figure A) Component parts of the vent panel assembly are illustrated in the proper installation sequence. STRAIN RELIEF MOUNT 1. Place all vent panel components on the vent frame inlet with the labeled side up, aligning them with the bolt holes. LEAD WIRE 2. If the B.D.I. Alarm System is used, visually inspect the adhesion of the strip to the seal and the electrical circuit. If the strip has become detached or the circuit has been broken, DO NOT INSTALL THE VENT PANEL. Ensure that the B.D.I. strip extends straight and flat. 3. Align and lower the vent frame outlet onto the vent panel. 4. If the B.D.I. Alarm System is used, installation of the strain relief device is necessary (see Figure B). Insert one assembly bolt into the vent frame near where the B.D.I. strip exits. Place the strain relief mount over the bolt and secure with a washer and nut. Hand-tighten only at this time. Insert the strain relief clip into the hole in the strain relief mount. Allowing sufficient slack for easy connection to the B.D.I. connector, secure the lead wire to the strain relief device by fastening the twist lock on the clip. Plug the B.D.I. connector into the leadwire connector using a slight twisting action.

5. Install all remaining bolts, nuts and washers. Using a cross torquing pattern (see Figure C), torque all nuts with a calibrated torque wrench at 20% increments of the recommended torque value shown in the table below. Repeat 20% increments and cross torquing pattern until final torque value is achieved. Recheck all nuts in rotational sequence at final torque value. The torque values listed in the table below are based on using grade 5 bolts. The use of lower grade bolts may prove unsatisfactory. RECOMMENDED TORQUE VALUE TABLE Size Torque 8-10 15 Ft Lbs / (20 N m) 12-24 25 Ft Lbs / (34 N m) 30-44 60 Ft Lbs / (82 N m) IV. Preventative Maintenance 1. Periodic visual inspection should be made to assure vent panel installation is free from structural damage and vent area is free of obstructions. 2. Risk assessment and an annual vent panel replacement are recommended. Vent panel service life is determined by system operating conditions. The effects of severe pressure/vacuum cycles, corrosion, temperature variations, or other adverse conditions must be evaluated by the user through actual service experience to determine optimal service life. 3. IF THE VENT PANEL IS NOT REPLACED PERIODICALLY WHEN EXPOSED TO THESE CONDITIONS, PREMATURE FAILURE OF THE VENT PANEL MAY OCCUR. EXAMPLE OF BOLT TORQUE SEQUENCE 20 4 22 12 14 8 16 24 1 17 28 6 26 10 Figure 'C' 18 2 23 9 15 25 5 27 7 13 11 21 3 19 4. To avoid extended downtime, maintain two spare vent panels in stock at all times for each vent frame in use. The number of spares required ultimately will be determined by service conditions. 28-BOLTS V. Customer Service If you wish to discuss your application, installation, or maintenance, please contact the Customer Service Department at our headquarters location.

B.D.I. ALARM SYSTEM OPERATING LIMITS TEMPERATURE: MAX CURRENT: MAX VOLTAGE: -40 F to + 400 F ( -40 C to + 204 C) 50 Milli Amps 24 VDC FULFILLS THE REQUIREMENTS OF DIRECTIVE 2014/34/EU (ATEX) FOR: protective system intended for use in potentially explosive atmospheres. Equipment or Conformity assessment performed by Notified Body no. 0359, Intertek Testing and Certification Limited, Leatherhead, Surrey, UK. BURST DISC INDICATOR (B.D.I. ): Sizes 25mm through 900mm (1 inch through 36 inches) Marked: II 1 G Ex ia IIC Tx Ga II 1 D Ex ia IIIC Tx Da I M1 Ex ia I Ma (Tamb = -40 C Ta +204 C) EC Type Examination Certificate: ITS13ATEX27734X THE MAXIMUM INTRINSICALLY SAFE INPUT PARAMETERS ARE AS FOLLOWS: Ui = 24V dc Ii = 50 ma Pi = 0.3W THE EQUIVALENT PARAMETERS ARE: Ci = 0 Li = 0 SPECIAL CONDITIONS FOR SAFE USE: 1. Temperature Class of the BDI sensor is marked as Tx, since the surface temperature is controlled by the process temperature being monitored. The sensor itself exhibits negligible temperature rise. 2. When located in an area requiring EPL Ga / Category 1G (e.g. Zone 0) hazardous area, the user shall ensure that electrostatic charging of the non-metallic parts cannot occur. 3. When provided with terminations by means of flying leads, these shall be terminated in an appropriately protected terminal box. 4. When installed, the BDI strip shall be provided with an IP rating of IP20 as a minimum. 5. For Group I applications, the BDI strip and terminations shall be protected to IP54 or better.

HEADQUARTERS // 3160 W. Heartland Drive Liberty, MO 64068 USA Ph (816) 792-1500 Fax (816) 792-2277 sales@contdisc.com contdisc.com Continental Disc Corporation reserves the right to alter the information in this publication without notice. Reproduction without written permission prohibited. 1998, 2001, 2003, 2004, 2008, 2010, 2011, 2012, 2014, 2016 Printed in U.S.A. Continental Disc Corporation