Bi Wave Plus. User Guide. LFT4906 Issue 5

Similar documents
Bi Wave Carer. User Guide. LFT5104 Issue 5

Nova. Rollator OWNERS HANDBOOK. Product Code: WA01063

Provides a one stop shop for all your electrically profiling beds frames and a full range of accessories to supplement the functionality of the bed

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

P POD SEATING SYSTEM USER S MANUAL

Kontrol Kube Advanced Owners Manual

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

User manual CuroCell Nova CX13 CuroCell Nova CX19 Alternating pressure system. Item number user manual:

AFC-50 Automatic French Fry Cutter Instruction Manual

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

S E L E C T I O N. Abdominal Crunch. User manual

OWNERS MANUAL PACKING INSTRUCTIONS PARAGLIDER EMERGENCY SYSTEM B-SAFE 120 L

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

Pediatric Lower Body Warming Blanket Model B203 Instructions for Use

Blue Series Hot Melt Hose with RediFlext II Hanger System

SUPPLIERS TO THE NURSING HOME INDUSTRY

Installation and User s Manual 12 x 10 MOTORIZED AWNING

Model Crosspoint Matrix

DOC Air Force One Installation Manual REV 002

ROOFTOP CARGO BAG (FRONT OF VEHICLE) HOOK (x4) ATTACHMENT STRAP (x4)

THIS CLIPPER IS INTENDED FOR HOUSEHOLD USE ONLY.

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

Est A TRADITION OF EXCELLENCE INSTRUCTION BOOK.

30m Foot Pedal Hose Reel

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Air2Care. Comfort & Pressure ulcer prevention PEČOVATELSTVÍ HEALTHCARE NURSINGCARE

Heyinovo. Disposable Biopsy Valves User Manual. Technical Publications. Document No: WI-RD-13-M07, Rev. B

WARMING BLANKETS INSTRUCTIONS FOR USE

FORM (Apr. 2006)

Contents. Introduction Technical description Adjusting your Goya The alternative methods of emergency parachute connection ...

Compass Home 8' x 8' No Tools Gazebo with Awning and Anchor Bags Assembly Instruction for Gazebo (no tools required)

MAX Series 9514 OPERATOR S MANUAL

The Cube Birthing Couch

MALTE. the compact and versatile posterior-walker. Instructions for use

Step by Step Set Up Guide

LBH18BPK. Instruction Sheet

OPERATOR INSTRUCTION MANUAL INCLUDING REPAIR PARTS FOR MODULAR GENERAL PURPOSE TENT SYSTEM (MGPTS) TYPE I

GLM300 Semi-auto Slicer

ORTHOPEDIC, TRAUMA TOURNIQUETS AND CUFFS

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

06/17. CHAILEY Toilet Seat INSTRUCTIONS FOR USE. Codes

Hose Reel Series L701/G701

Urea/Adblue Hose Reel

Drive DeVilbiss Pressure Area Care.

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

Retractable Hose Reel

METCALFE EC12. Electrically Operated Potato Chipping Machine INSTRUCTION MANUAL

User s Manual Trampoline 8

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

/ Tool and Equipment Safety Tether System (T.E.S.T.S)

Legacy Basic Acoustical Shell

Community & Premium Homecare Bed Range

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

300 ft. 5/8 Hose wagon

ROOFBAG CAR TOP CARRIER INSTALLATION BOOKLET

LVS BASE VEST OPERATOR S MANUAL

PM-X IR SURGICAL POWER & ACCESSORIES

1. INTRODUCTION GENERAL INFORMATION WORKING PRINCIPLE CUTTING SECTION SPECIFICATIONS INSTRUCTIONS FOR USE 5

INSTALLER AND OWNER GUIDE

LM601 Landmark Permanent Blind

BOAT COVER USER GUIDE BOAT ACCESSORIES

DO NOT USE WITH CROSSBAR SPREAD LESS THAN 24.

AERODYNE RESEARCH CORPORATION RACE TRACK ROAD, TAMPA, FLORIDA, 33626, USA PHONE (813) FAX

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

User Guide. Tripod. flowtech 75 Tripod. Part No. V

Solar Power Shade INSTRUCTION MANUAL

FEATURES & BENEFITS OF THE TOW PRO LITE :

Rooftop Tent Owners Manual

quick and easy installation guide

Air Mattress. Model No.: EAM-DQ1 & EAM DT1. Questions or Concerns? (855)

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

FORM Rev. A (Feb. 2004)

10 X 20 X 8 Dome Canopy

OWNER S MANUAL. ezup.com. 13 x 13 (4.0m x 4.0m) 10 x 10 (3.0m x 3.0m) 16 x 16 (5.0m x 5.0m)

Otter Pro XT Cabin Installation and Set-Up Instructions

JOINTED ARM AWNING SWINGLINE CASSETTE

Hitch Hiker Operating Instructions

1000M MANUAL Signature Series Slicer OPERATORS MANUAL

Advantage Plus TIM-3600 Series Reel

The ULM CASE III Emergency Case. Description and instructions for use

PS-10 PS-12D PS-12. Primo Slicer Manual FOR OPERATOR-DO NOT DISCARD

Read all instructions and warnings before using this fireplace. WARNING

Clay Adaptors & Insert Stove Kits

VACATION'R A ROOM FOR VERTICAL ARM AWNINGS

» AQUILA 320(HIGH TOP) «

Getting Started Guide

User Manual. Zitzi Carseat pro

BERYL Service Guide. Travel Adjust OTT Change

Fibre Mesh Wedge User Instructions. Simple Stuff Works

Smart-UPS Installation Guide 750/1000/1500/2200/3000 VA 120/230 Vac 500 VA 100 Vac Tower Important Safety Messages

FISH CAT SCOUT OWNER S MANUAL

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

Invacare. Non-Powered Surfaces

GEAR GUIDE CABELA S SET NUMBER:

AUTO REWIND HOSE REEL WITH 50 FOOT HOSE. Model 46320

View slicer 800-S. meat pusher. handle. thumb. screw. sharpener. table release. handle. securety. screw. knifescraper

COPPER RIVER CABIN TENT

33100 LH - Batwing Awning RH - Batwing Awning

Solera Family and Screen Room. Installation and Owner s Manual (For Aftermarket Applications) Table of Contents

Transcription:

Bi Wave Plus User Guide LFT4906 Issue 5

Bi Wave Plus Use and Care Instructions The BI WAVE PLUS System is suitable for patients showing any of the following characteristics: Assessed to be up to very high risk of pressure sore development. Require healing of any grade of pressure ulcers. Have some mobility whilst in bed or are turned regularly. The BI WAVE PLUS System reduces skin surface pressure at frequent intervals. This encourages the blood flow necessary to maintain healthy tissue, thereby preventing pressure sores even in the most vulnerable patients. Immobile patients or those not able to be turned frequently and therefore at greater risk can be nursed on the CAIRWAVE Therapy System.

BI WAVE PLUS CONTENTS SECTION PAGE A GETTING STARTED 2 List of Parts 2 Setting Up 2 B PROFILING AND GATCHING 5 Profiling 5 Gatching 6 C MOVING THE BED AND POWER CUTS 7 D CPR (CARDIO PULMONARY RESUSCITATION) 8 E DEFLATION, REMOVAL, CARRYING AND STORAGE 9 Deflation 9 Removal 9 Carrying and Storage 9 F ALARMS AND FAULT FINDING 10 Alarms 10 Fault Finding 11 G CLEANING 11 H USER SERVICING AND SERVICE 12 I TECHNICAL DATA 13 1

SECTION A GETTING STARTED LIST OF PARTS Check that all parts are present before assembling the system. Mattress and Cover Power Unit Airpipe SETTING UP The BI WAVE PLUS system can be used on all standard hospital, domestic and profiling beds. To install the system, carry out the following procedure: 1. Lower the bed if possible. Remove the existing mattress from the bed frame. 2. Check that there is nothing to damage the mattress, such as sharp edges or springs. If your bed frame does not have a solid base the use of a fracture board or similar firm base is advisable to ensure maximum benefit. 2

3. Place the mattress on the bed with the airpipe at the foot of the bed. 4. Loosely secure the mattress to the bed frame using the straps provided. Do not fasten the straps to removable head or foot boards. 5. Hook the power unit over the foot of the bed or place on the floor if preferred. PUSH DOWN BUCKLE TO LOCK STRAP MATTRESS SECURING STRAPS* MATTRESS/AIRPIPE CONNECTOR POWER UNIT POWER LEAD FOR QUICK RELEASE OF BUCKLES PULL LOOSE END OF STRAP AWAY FROM BUCKLE CPR CONNECTOR * MAKE SURE THE SECURING STRAPS ARE ATTACHED TO THE MOVING PARTS OF THE BED FRAME ONLY. 6. Connect the airpipe to the mattress by lining up the outer pin and arrow on the locking ring, then aligning the inner pin and slot and pushing the two halves of the connector firmly together until a click is heard. LOCKING RING ALIGN OUTER PIN AND ARROW ALIGN INNER PIN AND SLOT. PUSH TOGETHER UNTIL A CLICK IS HEARD 3

7. Connect the airpipe CPR handle onto the power unit as shown, ensuring the PULL FOR CPR label is visible. 8. Plug the mains lead into a suitable electrical socket. Switch the power unit on using the on/off switch located on the left side of the power unit. The audible alarm will sound and the three front panel lights will flash to complete the self test phase. The amber POWER light will stay on and the mattress will start to inflate. 9. The system will take approximately 25 minutes to reach full inflation pressure, at which time the green NORMAL light will come on. During this start up phase the red FAULT light may come on and the audible alarm sound, if this occurs turn the power unit off and back on again to reset the alarm. Once inflated, check the securing straps and tighten if required. For maximum benefit, use only one sheet loosely placed over the mattress. If the sheet is tucked in ensure that it is left loose over the mattress to avoid hammocking. Once a patient is placed on the mattress the system will adjust automatically to the patient characteristics (weight/position) to provide optimum clinical benefit for each patient. The mattress may feel firm at first until it has adjusted to the individual. Allow approximately 24 minutes for this automatic adjustment to be completed. If the mattress does not perform as described above, please refer to Section F of this guide, Alarms and Fault Finding. 4

SECTION B PROFILING AND GATCHING The BI WAVE PLUS system mattress can be used in a profiled position to provide pressure relief for patients sitting up in bed, and/or a gatching position for patients where the lower section of their bed is raised. CAUTION: Do not fasten securing straps to removable head or foot boards, this may impede their removal in an emergency. PROFILING (Sitting Up) If using a bed with a manually operated back rest, release the mattress securing straps, lift the head end of the mattress and adjust the back rest to the required angle. Move the mattress to the desired position and, using the centre and foot end straps, secure the mattress to the main bed frame. If using a bed with a powered/mechanical back rest, release the mattress securing straps and raise the back rest to the required position. Move the mattress to the desired position and secure to the moving parts of the bed ensuring the straps are positioned and fastened so they are not stretched or interfere with the bed mechanism when used in its various positions. DO NOT FASTEN STRAPS TO REMOVABLE BED HEAD SECURING STRAPS* * MAKE SURE THE SECURING STRAPS ARE ATTACHED TO THE MOVING PARTS OF THE BED FRAME ONLY. 5

GATCHING (Bending at the Knees) Release the mattress securing straps and gatch the knee section as required, being careful not to disturb the power unit by putting unnecessary strain on the airpipe. Move the mattress to the desired position and secure to the moving parts of the bed ensuring the straps are positioned and fastened so they are not stretched or interfere with the bed mechanism when used in its various positions. SECURING STRAPS* * MAKE SURE THE SECURING STRAPS ARE ATTACHED TO THE MOVING PARTS OF THE BED FRAME ONLY. 6

SECTION C MOVING THE BED AND POWER CUTS WARNING: The patient will not receive the benefits of the BI WAVE PLUS System while it is disconnected and the power unit is turned off. Therefore they should be reconnected as soon as possible once the bed has been moved to its new position. If you need to move the bed or carry out nursing procedures with the mattress still inflated (but static) or in the event of a mains power failure, then follow this simple procedure: 1. Disconnect the mattress from the power unit by turning the locking ring on the airpipe connector to line up the pin and arrow. 2. Push the locking ring so the pin and arrow move together and pull the two halves of the airpipe apart. 3. Turn off the power unit and unplug from the electrical socket. Press the alarm reset button on the front of the power unit to reset the audible alarm. 4. The mattress will remain inflated for over 24 hours. The bed can now be moved. 5. When the bed has been moved to its new location, reconnect the two halves of the airpipe, plug in the power unit to an electrical socket and turn the power unit on. LOCKING RING ALIGN PIN AND ARROW PULL LOCKING RING. ALLOW AIRPIPE TO COME APART 7

SECTION D CPR (CARDIO PULMONARY RESUSCITATION) In the event of cardiac arrest, disconnect the CPR handle from the power unit (as shown below). The mattress will immediately begin to deflate, allowing cardio pulmonary resuscitation. PULL CONNECTOR TO RELEASE 8

DEFLATION SECTION E DEFLATION, REMOVAL, CARRYING AND STORAGE To deflate the mattress, follow these easy steps: 1. Turn off the power unit and unplug from the electrical socket. An audible alarm will sound to indicate the unit is turned off. Cancel this alarm by pressing the reset button on the power unit. 2. Disconnect the airpipe from the power unit as detailed in the CPR Section of this manual. The mattress will immediately start to deflate. If you wish to deflate quicker, apply downward pressure to the mattress and press out as much air as possible. REMOVAL 1. Roll the mattress from the head end, with the top surface inward, tucking in the loose straps until completely rolled. Lay the airpipe along the rolled mattress. AIRPIPE AIRPIPE LIFTING STRAP/ CARRYING HANDLE 2. Use the foot end straps to fasten the mattress in the rolled position and hold the airpipe in place. 3. Unhook the power unit from the bed frame and coil the power lead for ease of storage. CARRYING AND STORAGE In order to help with carrying and storage of the system, a high quality carrying bag for the mattress and the power unit is available. Please contact your supplier for details. 9

SECTION F ALARMS AND FAULT FINDING ALARMS The BI WAVE PLUS system is equipped with a sophisticated set of alarm functions. These alert the user to the status of the available mains supply and any mattress defect. In normal conditions with mains power available, the power unit turned on and the mattress fully inflated and alternating, the status light on the power unit front panel will be green and the mains light amber. If at any time the mains power should be removed from the power unit, an audible alarm will be heard. The audible alarm may be cancelled by pressing the reset button on the power unit. If the product develops a defect whilst in use, the fault light will turn red and an audible alarm will be heard. This alarm may be cancelled by turning the mains power switch, on the side of the power unit, to the OFF (O) position and then pressing the reset button. SPRING LOADED BED HOOKS AIR INTAKE STATUS LIGHTS: GREEN - RUNNING NORMALLY AMBER - SYSTEM INFLATING RED - FAULT ALARM RESET BUTTON 10

FAULT FINDING SYMPTOM No lights on power unit Status light red and alarm sounding or alarming but no lights ACTION Check power unit is connected to the mains power supply and that the power unit switch is turned to the ON (1) position Turn the mains switch on the power unit OFF then ON again and press reset. If the mains light does not illuminate, mains power to the power unit has been lost. Check that the power unit is connected to the mains supply and that the power unit switch is turned to the ON (1) position If the problem persists, contact your supplier. If the alarm clears then returns after 30 minutes, check air connection between power unit and mattress, ensuring that all air connectors are pushed fully home and the air pipe is not folded or bent causing air flow to be reduced. Turn mains switch on power unit OFF then ON again and press reset. SECTION G CLEANING It is recommended that the system is cleaned regularly and after each patient use. CAUTION Do not immerse the power unit whilst cleaning Ensure the power unit is switched off and disconnected from the supply before cleaning. mains In many cases it will not be necessary to remove the mattress from the bed prior to cleaning. The power unit can be cleaned by wiping down with a cloth dampened with one of the solutions in 1 or 2 below. The mattress and mattress cover can be cleaned using the following simple procedure: 1. Liberally swabbing with hot water containing detergent, then drying. 2. Swabbing with a solution of sodium hypochlorite (up to 10,000 parts per million available chlorine), then drying. The mattress cover can also be machine washed to a maximum temperature of 71ºC. To remove the cover, turn the power unit off, disconnect the airipipe, unzip the cover, undo the 4 clips securing the mattress to the cover and pull the airipipe through from the inside of the cover. The mattress can now be taken out of the cover. Remove the foam base from the cover prior to washing the cover. Replacement is the reverse of the above. The system may also be decontaminated by using ETO (Ethylene Oxide) or the Draeger Method. CAUTION Do not high temperature Autoclave or use Phenolic based products for cleaning. 11

SECTION H USER SERVICING AND SERVICE The BI WAVE PLUS System has been designed for ease of use and contains no user serviceable items. If you have any queries about the operation of the system contact your supplier. If the system becomes defective during the warranty period, it will be repaired or replaced free of charge in accordance with the system warranty. To help us identify the system when telephoning, please make a note of the serial number which you will find on the label on the rear of the power unit or on the foot end of the mattress. Isolate from mains before removing cover. Unit contains no user serviceable parts. Only to be opened by qualified service personnel.! 12

Cycle Control Cycle Time Supply Voltage Power Rating Fuse Rating Noise Level SECTION I TECHNICAL DATA Purpose designed distributor valve supplying operating air to the inflatable cells 12 minutes 220/230 Vac 50Hz 40 watts 2A NC30 Nominal Dimensions Mattress (Inflated) Power Unit Length: 1900mm Height: 300mm Width: 880mm Width: 220mm Height: 230mm Depth: 130mm Weight: 8.1kg Weight: 2.7kg Electrical Safety Conforms to BSEN 60601-1 Classification Mode of Operation Symbols Class 2, Type B Continuous Alternating Current I O Mains Switch - 1 (On) Power connected to the mains supply 0 (Off) Power disconnected from mains supply Class 2 Type B Environment (Usage and Storage) EMC Air Humidity: 10% to 85% Ambient Temperature: -10 C to +60 C This equipment complies with EMC requirements. If effects are noticed the affected equipments should be moved apart. This product carries the CE mark in accordance with EC Directive on Medical Devices (93/42/EEC). Pegasus Limited cannot be held responsible for any damage caused to our products (by foreign objects needles, sharps, eating utensils, etc) other than due to normal wear and tear as defined in the product warranty agreement. Nor for any injury or incident which relates to the use of cot sides, profiling or any other mechanical or electrical device used in conjunction with this product unless supplied and/or manufactured by Pegasus Limited. 13

PEGASUS LIMITED Pegasus House Waterberry Drive Waterlooville Hampshire PO7 7XX England Tel: +44 (0) 23 9278 4200 Fax: +44 (0) 23 9278 4250 E-Mail: custserv@pegasus-uk.com Website: www.pegasus-uk.com PEGASUS and the associated device marks are Trademarks of Pegasus Limited. Pegasus Limited has a policy of continuous product improvement and reserves the right to amend specifications presented in this brochure. ISO ISO 13485 9001 UKAS QUALITY ASSURED FIRM QUALITY ASSURED FIRM BRITISH HEALTHCARE BHTA TRADES ASSOCIAT ION LFT4906 Issue 5 Pegasus Limited 2003