A Pre-Paid Return Label is included (optional) *Call for pick up no later than the above return date to avoid additional rental fees

Similar documents
1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

Thomas Scientific Swedesboro, NJ U.S.A.

FORM (Apr. 2006)

Instructional Booklet

Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual

SPIRAL SLICER Instruction Manual Model #5280 & 5280M. Part No Revised Feb. 2010

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

Instructions for Use: Duodenoscope Sampling Kit

Gas Conversion Kits and Instructions

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

Leica CE/ Leica CN. Knife holder

User s Manual Trampoline 8

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

AMS Gas Vapor Probe Systems (GVP)

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

300 Model 870 Four Wheel Hose Cart Owner s Manual

DeZURIK AM-SERIES MANUAL GEAR ACTUATOR USED ON BUTTERFLY VALVES

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

NNIN Nanotechnology Education

HOSE ASSEMBLY CLEANLINESS

Globe Slicer Safety Tips

How to safely collect blood samples by phlebotomy from patients suspected to be infected with Ebola or Marburg

JARVIS. Model 70 Airsnip Air Powered Scissors

Emergency Management Portable Water System Set-up and Operations Manual

DIAMOND TECH INTERNATIONAL Innovations For Creativity DIAMOND LASER BAND SAW OPERATIONS MANUAL

functionality with the necessary maintenance tools stored in a convenient built in tool box, as well as parallel handles for

LESSON ASSIGNMENT. Surgical Asepsis and Sterile Technique. After completing this lesson, you should be able to:

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

Urea/Adblue Hose Reel

CONVERSION INSTRUCTIONS

CONVERSION INSTRUCTIONS

Advantage Plus TIM-3600 Series Reel

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

Solera Classic Awning

Instructions for Use A-dec Quick-Disconnect Syringes

Blue Series Hot Melt Hose with RediFlext II Hanger System

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

Installation GUIDE. NKVGR Natural Conversion Kit for 7 Series Ranges/Rangetops

LBH18BPK. Instruction Sheet

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

PR-429BF-600M. Bell 429 Blade Fold Kit Operations Manual

FORM Rev. A (Feb. 2004)

AND LOAD CANOPY RACK SPECIFICATIONS

Cold Water Rheology Kit

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS C2204A

Section 8 - Supplements

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

Hike Water Microfilter GB DE FRA NL DK SWE NOR FIN IT ESP POR RUS

VEPR Round Drum Disassembly and Assembly

NEWMAR SERVICE SCHOOL

Operating Instructions

POP-UP OPTION USER HARDWARE MANUAL. EdgeTech 4 Little Brook Road West Wareham, MA _REV_B 8/29/2018

Glammbox Crea7ion.E. GlammFire. Crea7ion by GlammFire. GlammFire

ASSEMBLY GUIDE. Customer Service: INCH² 3-BURNER & 545 INCH² 3-BURNER

UNODOS + / FLOCDOS +

Wenger Corporation 2014 Printed in USA 05/14 Part #049B015-09

Operating Instructions

CRD120SC TUBING CUTTER

Get A Grip! Student Activity 1D Introduction: Materials: (per group) LESSON 2

Field Situation - How to safely collect oral swabs (saliva) from deceased patients suspected to be infected with Ebola

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

AUTO REWIND HOSE REEL WITH 50 FOOT HOSE. Model 46320

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

In-Floor Parts. UltraFlex 2 Replacement Parts Prices are each unless designated as a kit ZODIAC POOL SYSTEMS CATALOG.

READ ME FIRST! IMPORTANT WARNING! ENG. Roof top tent

How to safely collect oral swabs (saliva) from deceased patients suspected to be infected with Ebola or Marburg

REMOTE SWABBING AND MICROBIOLOGICAL SAMPLING TOOLS (PATENTED) & CLEANING VALIDATION COUPONS REMOTE SWABBING & MICROBIOLOGICAL SAMPLING TOOLS

TC42 TRANQUILITY BURNER KIT INSTRUCTIONS

Assembly Instructions

SERVICE PARTS LIST AND ASSEMBLY INSTRUCTIONS

INSTALLATION GUIDELINES

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS. Part # A7006

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

LDR Brachytherapy Seed Sterilization and Sorting Tray

TRAVEL-SMART AWNING SERIES » LYNX 200 LOW TOP « Model No Issue:October Document-No.: LYNX 200 LOW TOP. Top Quality Camping

How to Set up Your Configurable (Home and Camping) Stir Fry Stove

Model 698/ and Model in 1 Hose Reel Owner s Manual

Water Filtration & Purification System

Auxiliary 63.5l Fuel Tank Ford/Mazda Pick-up Truck 2012-Current READ ME! IMPORTANT WARNING!

Alien Flier Zip Line Products Installation/Owner s Manual

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

Combi Water Microfilter (Model # ) Combi Replacement Cartridge (Model # ) GB DE FRA NL DK SWE NOR FIN IT ESP POR

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

BROEN UNIFLEX FITTINGS FOR WATER BROEN UNIFLEX TM FITTINGS FOR WATER

* * KR54-F, KR9854 & KR9954 Installation Instructions. Read All Warnings Before Starting Installation! Index:

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING

Performing Hand Hygiene Using an Alcohol-Based Handrub

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

Colonial and Grand Colonial Fire Pit Tables. Installation Instructions for

Cloze Control Installation Instructions I001 June 2016

INSTALLATION INSTRUCTIONS TOWNSEND

PL500A Platform Extension

Installation Guide: Round Trampoline

VAC N BLO CAR VAC COMMERCIAL SERIES

Kontrol Kube Advanced Owners Manual

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

Transcription:

TM TRACE AnalyticsLLC the compressed air testing experts the AirCheck Lab YOUR AIRCHECK for AirCheck TM Kit KX00PR TM NOTEBOOK RENTAL PROGRAM RENTAL PERIOD *RETURN DATE A Pre-Paid Return Label is included (optional) *Call for pick up no later than the above return date to avoid additional rental fees TRAINING VIDEOS AVAILABLE ONLINE: AIRCHECKLAB.COM 2013-2018 Trace Analytics, LLC. All rights reserved. 15768 Hamilton Pool Rd. Austin, TX 78738 ServiceTeam@airchecklab.com (p) 1.800.247.1024 (f) 512.263.0002

1 TABLE OF CONTENTS CHAIN OF CUSTODY 3 How to fill out the form PINOCCHIO SAMPLING 5 Important Reminders 6 Media Handling 7 Equipment Reference 9 Sampling Procedure 10 SHIPPING INSTRUCTIONS 15 Important Reminders TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000

2 TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000

3 CHAIN OF CUSTODY INSTRUCTIONS DON T FORGET TO FILL OUT ALL FIELDS 1/1/2018 1/1/2018 Air Knife Before Blind - #1 1/1/2018 Air Knife #2 1/1/2018 Air Knife After Blind - #3 TRACE ANALYTICS, LLC N/A Air N/A AUSTIN, TX 512-263-0000 N/A 100 N/A N/A 10 N/A

4 TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000

5 PINOCCHIO SUPER II (KX00) SAMPLING INSTRUCTIONS Microbial Impaction Sampler for Compressed Air & Gas Monitoring Fast sampling time - Collects more than 1000 liters of air/gas in just a few minutes Easy-to-use - Compact size allows use in limited space. Simple operation enables many operations to more accurately report air/gas quality and minimize false positives from operators. The unit can be easily and aseptically connected to the desired points of sample. Durable construction - 99% of the SAS units sold since 1979 in North America are still in use today Thank you for choosing Trace for your compressed air testing. If you have any questions or concerns, contact us at 512-263-0000 x3. TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000

6 IMPORTANT REMINDERS ü Return the Pinocchio Sampler on time! If you rented the KX00 Pinocchio Sampler, your rental is on a per-day basis. Please refer to your purchase order for the number of days you are scheduled to have the sampler. If additional days are required, contact Trace for availability. The KX00 is set on a strict delivery rotation with other clients, and so must be returned on time. Failure to return the sampler on time will result in additional penalty fees. ü Don t forget to send your Chain of Custody back with your sample! The chain of custody is essential for proper analysis and reporting, and must accompany all samples submitted to the laboratory. Please be sure to fill out all fields, including: PO Number, Sampler and Flowmeter Serial Numbers, Plate Lot Number, Plate Expiration Date, Collection Dates, Sample Description, Analysis Type, Gas Type, Flow Rate, Sample Time, and Technician Contact Details. ü Label and Parafilm Your Plates! Each sample must be properly labeled with sample ID exactly as written on the chain of custody to prevent misidentification. Labeling is most legible when done with a fine-tipped permanent marker on the underside of the plate. Parafilm must be used to wrap each plate to ensure plates do not become contaminated. TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000

7 MEDIA HANDLING REMINDERS To ensure the validity and integrity of your agar plates, please follow these instructions: UPON RECEIPT 1. Keep the 10 pack of plates sealed in their plastic bags until ready to sample. 2. Store plates in the dark at 36-77 F in their original bags. Do not freeze or overheat plates. WHEN SAMPLING 1. CAUTION: Plates are provided in the unlocked position. When opening the plastic bags, plates may fall out and open, rendering them contaminated and unusable. 2. When you begin sampling, don t forget remove the lid from the plate, and place the plate in the sampler. 3. When you re finished sampling, be sure to return the lid to the plate and lock it by twisting the base and the lid of the plate into the locked position. Plates can be easily unlocked by untwisting. 4. Don t forget mark each plate with a Sample ID# on the underside of the plate. TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000

8 TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000

9 Effective Date: 3/01/18 Sampling Instructions for Microorganisms Revision No.: 01 KX00 Pinocchio Super II Compressed Air Sampler SAMPLING EQUIPMENT REFERENCE This document is proprietary property of Trace Analytics, LLC and is not to be duplicated, discussed, or otherwise disclosed in whole or in part in any manner whatsoever without the express written consent of Trace Analytics, LLC.

10 Effective Date: 3/01/18 Revision No.: 01 Sampling Instructions for Microorganisms KX00 Pinocchio Super II Compressed Air Sampler PROCEDURES Technician Notes: Refer to your purchase order in regard to quantity of blinds requested at time of order. Two blinds (before and after) for each point, and a single sterility blank: ISO 8573-7 compressed air/gas sampling procedures requires two blind/control samples; one before the compressed air/gas sample and one after. A sterility blank is also required. Sterility Blank: ISO 8573-7 requires an agarose plate that travels with you from receipt of equipment to shipment to testing lab. This plate should never be opened. Simply lock and parafilm the plate and return to the testing lab with your regular samples. Pinocchio Super II Compressed Air Sampler is validated at 100liters/min (lpm) for 10 minutes of use. Familiarize yourself with the provided timer before taking samples. 1. Personal Protective Equipment 1.1. Don personal protective equipment that includes: lab coat, gloves, face mask, hair net if needed, and safety goggles if working with aerosolized disinfectants. 1.2. Once gloves are put on, refrain from touching your face or other areas not pertaining to the Pinocchio equipment and/or media plates. 1.3. Throughout testing make sure TSA plates remain in the upright position to avoid lids falling off. 2. Prepping the Air/Gas Line 2.1. Verification and adjustment of tested gas must never exceed 60psi. Technicians may find it helpful to use our accessories bag: quick disconnects, clamps, barbs, ball valve, and pressure gauge. 2.2. Do not use pressure over 60 psi as it will damage the sampler. This document is proprietary property of Trace Analytics, LLC and is not to be duplicated, discussed, or otherwise disclosed in whole or in part in any manner whatsoever without the express written consent of Trace Analytics, LLC.

11 Effective Date: 3/01/18 Sampling Instructions for Microorganisms Revision No.: 01 KX00 Pinocchio Super II Compressed Air Sampler 3. Assembling the Pinocchio Super II Compressed Air Sampler 3.1. Remove protective caps from Pinocchio before operating the equipment. 3.2. Position the stainless-steel base (A) in front of the operator. 3.3. Connect the pressure gauge (F) on top of the central block. 3.4. Connect the air inlet connection (D) on the back of the central block. 3.5. Connect the air outlet connection (P) on the top of the central block. 3.6. Slide the small triangular stainless-steel support (E) on the front of the central block to support the flowmeter. 3.7. Connect the air flow meter connection (B) on the front of the central block. 3.8. Slide the funnel support (M) onto the base. 3.9. Position the funnel (H) on its support and connect it to the air outlet (P). 3.10. Connect the sterilized 3ft braided tubing provided to your air/gas line and the air inlet connection barb (D). Use the clamps and nut driver from the accessories bag for a more secure fit. 4. Taking Before Blind Samples (See Technician Notes): 4.1. Before each sample: Change gloves or disinfect current gloves with alcohol and allow to dry. See Note 9.1. 4.2. Unscrew the contact plate housing (L) from the collar (I). 4.3. Using the alcohol wipes provided, wipe down the inside of the plate housing and the inside of the collar. Wait 2-5 seconds until the area is dry. 4.4. Place a labeled media plate onto the housing clips (inside L). Remove the lid of the contact plate and place on a clean surface face down. Do not touch the inside of the plate or the inside of the plate s lid. 4.5. Immediately screw the contact plate housing (L) back into the collar (I), gently. Too much force can result in the plate falling off the clips. 4.6. Start the timer for 30 seconds. No air/gas is tested during blinds. 4.7. Unscrew the contact plate housing (L), immediately and carefully place the lid on the plate, avoid touching any exposed portion of the contact plate, and then remove the plate from funnel. 4.8. Carefully set the contact plate lid onto the base and rotate until locked. Remove a single strip of parafilm from its paper backing and stretch it to wrap around the side rim of the plate, securing the lid and base together. 4.9. Use a permanent marker to label the plate number on the base of the contact plate. 4.10. Fill out the Chain of Custody form to reflect labeled plate description. 4.11. Place sealed/labeled contact plate in the provided sterile bag. Up to 8 sealed plates can fit in a single sterile bag provided. This document is proprietary property of Trace Analytics, LLC and is not to be duplicated, discussed, or otherwise disclosed in whole or in part in any manner whatsoever without the express written consent of Trace Analytics, LLC.

12 Effective Date: 3/01/18 Revision No.: 01 Sampling Instructions for Microorganisms KX00 Pinocchio Super II Compressed Air Sampler 5. Taking Test Samples (Do not exceed 60psi air/gas pressure): 5.1. Verify knobs D, D1, D2 are completely closed (clockwise turn). 5.2. Completely open (counterclockwise turn) the knob on the flowmeter, if a knob is present. 5.3. Open your air/gas line (maximum 60psi). 5.4. Open (counterclockwise turn) D1 completely. 5.5. Slowly open D, the flowmeter will begin to measure your flowrate. When you ve reached 100L/min, close D1. Your flowrate is now established for this point of use, do not adjust D again. 5.5.1. Total Volume Air Tested Calculation: Flowrate (lpm) x Time (min)= Total Volume Air Tested (liters) 5.6. Now you re ready to take a sample from your compressed air/gas. 5.7. Before each sample: Change gloves or disinfect current gloves with alcohol and allow to dry. See Note 9.1. 5.8. Unscrew the contact plate housing (L) from the collar (I). 5.9. Using the alcohol wipes provided, wipe down the inside of the plate housing and the inside of the collar. Wait 2-5 seconds until the area is dry. 5.10. Place a labeled media plate onto the housing clips (inside L). Remove the lid of the contact plate and place on a clean surface face down. 5.11. Immediately screw the contact plate housing (L) back into the collar (I), gently. Too much force can result in the plate falling off the clips. 5.12. Set the timer for 10 minutes; which is required to achieve 1000L total volume of air at 100lpm. 5.13. Open D2 (counterclockwise) completely. D2 allows the measured air/gas to directly enter the Pinocchio funnel. Start timer. 5.14. When the timer goes off, completely close D2. 5.15. Unscrew the contact plate housing (L), immediately and carefully place the lid on the plate, avoid touching any exposed portion of the contact plate, and then remove the plate from funnel. 5.16. Carefully set the contact plate lid onto the base and rotate until locked. Remove a single strip of parafilm from its paper backing and stretch it to wrap around the side rim of the plate, securing the lid and base together. 5.17. Use a permanent marker to label the plate number on the base of the contact plate. 5.18. Fill out the Chain of Custody form to reflect labeled plate description. 5.19. Place sealed and labeled contact plate in the provided sterile bag. This document is proprietary property of Trace Analytics, LLC and is not to be duplicated, discussed, or otherwise disclosed in whole or in part in any manner whatsoever without the express written consent of Trace Analytics, LLC.

13 Effective Date: 3/01/18 Sampling Instructions for Microorganisms Revision No.: 01 KX00 Pinocchio Super II Compressed Air Sampler 5.20. Up to 8 sealed plates can fit in a single sterile bag provided. 6. Taking After Blind Samples 6.1. Before each sample: Change gloves or disinfect current gloves with alcohol and allow to dry. See Note 9.1. 6.2. Unscrew the contact plate housing (L) from the collar (I). 6.3. Using the alcohol wipes provided, wipe down the inside of the plate housing and the inside of the collar. Wait 2-5 seconds until the area is dry. 6.4. Place a labeled media plate onto the housing clips (inside L). Remove the lid of the contact plate and place on a clean surface face down. Do not touch the inside of the plate or the inside of the plate s lid. 6.5. Immediately screw the contact plate housing (L) back into the collar (I), gently. Too much force can result in the plate falling off the clips. 6.6. Start the timer for 10 seconds. No air/gas is tested during blinds. 6.7. Unscrew the contact plate housing (L), immediately and carefully place the lid on the plate, avoid touching any exposed portion of the contact plate, and then remove the plate from funnel. 6.8. Carefully set the contact plate lid onto the base and rotate until locked. Remove a single strip of parafilm from its paper backing and stretch it to wrap around the side rim of the plate, securing the lid and base together. 6.9. Use a permanent marker to label the plate number on the base of the contact plate. 6.10. Fill out the Chain of Custody form to reflect labeled plate description. 6.11. Place sealed/labeled contact plate in the provided sterile bag. Up to 8 sealed plates can fit in a single sterile bag provided. 6.12. Each new Point of Use location tested needs to have the flowrate measured and adjusted prior to taking a compressed air/gas sample. 6.13. New Point of Use sample points will require, new sterile tubing or the tubing to be disinfected with 70% alcohol and dried (See Note 8.2). 6.14. ISO8573-7 requires before and after blinds at each Point of Use location. This document is proprietary property of Trace Analytics, LLC and is not to be duplicated, discussed, or otherwise disclosed in whole or in part in any manner whatsoever without the express written consent of Trace Analytics, LLC.

14 Effective Date: 3/01/18 Revision No.: 01 Sampling Instructions for Microorganisms KX00 Pinocchio Super II Compressed Air Sampler 7. Before You Finish 7.1. Sterility Blank: A single locked and UNOPENED plate should travel with the technician to all sites. At the conclusion of all sampling, the plate should be taped/parafilmed. Please label as SB, and place in the sterile bag. The sterility blank gives confidence to both the customer and testing lab that there is not a contamination variable associated with the plate manufacturer, shipment, sampling, or testing lab procedures. 7.2. Packing Your Plates: Tightly closed sterile bags containing the contact plates are then placed in the bottom of the provided insulated cooler with frozen ice packs placed gently on top. The sealed cooler is then placed in the shipping box. 8. Changing Point of Use Locations 8.1. Each new Point of Use location tested needs to have the flowrate measured and adjusted prior to taking a compressed air/gas sample. 8.2. New Point of Use sample points will require new sterile tubing or the tubing to be disinfected with 70% alcohol and dried. 8.2.1. Direct a stream of 70% or greater isopropanol alcohol inside the tubing. 8.2.2. Insert plugs onto the ends of tubing. 8.2.3. Move tubing back and forth to rinse internal surfaces completely. 8.2.4. Remove the plugs and expel the isopropanol alcohol into a suitable container. 8.2.5. With both ends facing downward, allow the isopropanol alcohol to evaporate. 8.3. ISO 8573-7 requires before and after blinds at each Point of Use location. 9. Notes 9.1. Clean the following items with alcohol before and after each use to eliminate cross-contamination: gloved hands, inside of contact plate housing (L), and collar (I). Cross contamination is a leading cause of erroneous CFUs and retesting requests. 9.2. See above instructions for proper cleaning of sterile tubing (8.2). This document is proprietary property of Trace Analytics, LLC and is not to be duplicated, discussed, or otherwise disclosed in whole or in part in any manner whatsoever without the express written consent of Trace Analytics, LLC.

15 SHIPPING INSTRUCTIONS For Samples Collected Monday through Thursday If you received 1 single Next Day shipping label: The equipment and samples will be returned together. Pack all plates back into insulated cooler with frozen ice packs and then insert cooler into the sample return box. Include Chain of Custody with samples and keep a copy for your records. We recommend shipping the plates the same day as they are collected. If not possible, the plates must be refrigerated (not frozen) and shipped the next day. Return samples and kit together using the Next Day shipping label. If you received a return label AND the sample return box has a Next Day label attached: The samples will be returned separately from the equipment. Pack all plates back into insulated cooler with frozen ice packs and then insert cooler into the small return box. Include Chain of Custody with samples and keep a copy for your records. Samples must be returned to the lab via Next Day delivery. We recommend shipping the plates the same day as they are collected. If not possible, the plates must be refrigerated (not frozen) and shipped the next day. Sampling equipment will ship separately using the label provided. IMPORTANT FOR SAMPLES COLLECTED ON FRIDAY Samples MUST be shipped using a Next Day SATURDAY delivery label o Early AM (UPS) or First Overnight (FedEx) Contact Trace for a new shipping label, additional cost will apply. TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000

16 THE AIRCHECK ACADEMY GET TRAINING DOCUMENTATION Visit the AirCheck Academy to test your compressed air knowledge and receive certificates of completion for ISO 8573, Sampling for PWO, and Sampling for Micro. Also check out our instructional videos and webinars on all things compressed air. Contact us to get set up with a login and password. You ll get full access to all content in the academy, as well as all exams. serviceteam@airchecklab.com 512-263-0000 x3 TRACE ANALYTICS, LLC AUSTIN, TX 512-263-0000