Bi Wave Carer. User Guide. LFT5104 Issue 5

Similar documents
Bi Wave Plus. User Guide. LFT4906 Issue 5

Nova. Rollator OWNERS HANDBOOK. Product Code: WA01063

Provides a one stop shop for all your electrically profiling beds frames and a full range of accessories to supplement the functionality of the bed

P POD SEATING SYSTEM USER S MANUAL

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

Kontrol Kube Advanced Owners Manual

S E L E C T I O N. Abdominal Crunch. User manual

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

AFC-50 Automatic French Fry Cutter Instruction Manual

Blue Series Hot Melt Hose with RediFlext II Hanger System

User manual CuroCell Nova CX13 CuroCell Nova CX19 Alternating pressure system. Item number user manual:

OWNERS MANUAL PACKING INSTRUCTIONS PARAGLIDER EMERGENCY SYSTEM B-SAFE 120 L

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Installation and User s Manual 12 x 10 MOTORIZED AWNING

Pediatric Lower Body Warming Blanket Model B203 Instructions for Use

DOC Air Force One Installation Manual REV 002

Compass Home 8' x 8' No Tools Gazebo with Awning and Anchor Bags Assembly Instruction for Gazebo (no tools required)

Model Crosspoint Matrix

SUPPLIERS TO THE NURSING HOME INDUSTRY

FORM (Apr. 2006)

30m Foot Pedal Hose Reel

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

/ Tool and Equipment Safety Tether System (T.E.S.T.S)

Est A TRADITION OF EXCELLENCE INSTRUCTION BOOK.

ROOFTOP CARGO BAG (FRONT OF VEHICLE) HOOK (x4) ATTACHMENT STRAP (x4)

Urea/Adblue Hose Reel

LBH18BPK. Instruction Sheet

Contents. Introduction Technical description Adjusting your Goya The alternative methods of emergency parachute connection ...

06/17. CHAILEY Toilet Seat INSTRUCTIONS FOR USE. Codes

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

THIS CLIPPER IS INTENDED FOR HOUSEHOLD USE ONLY.

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

Heyinovo. Disposable Biopsy Valves User Manual. Technical Publications. Document No: WI-RD-13-M07, Rev. B

WARMING BLANKETS INSTRUCTIONS FOR USE

ORTHOPEDIC, TRAUMA TOURNIQUETS AND CUFFS

OPERATOR INSTRUCTION MANUAL INCLUDING REPAIR PARTS FOR MODULAR GENERAL PURPOSE TENT SYSTEM (MGPTS) TYPE I

Hose Reel Series L701/G701

LM601 Landmark Permanent Blind

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

User s Manual Trampoline 8

METCALFE EC12. Electrically Operated Potato Chipping Machine INSTRUCTION MANUAL

The Cube Birthing Couch

MALTE. the compact and versatile posterior-walker. Instructions for use

Legacy Basic Acoustical Shell

BOAT COVER USER GUIDE BOAT ACCESSORIES

Community & Premium Homecare Bed Range

» AQUILA 320(HIGH TOP) «

quick and easy installation guide

FORM Rev. A (Feb. 2004)

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Drive DeVilbiss Pressure Area Care.

GLM300 Semi-auto Slicer

Solar Power Shade INSTRUCTION MANUAL

Retractable Hose Reel

The ULM CASE III Emergency Case. Description and instructions for use

Otter Pro XT Cabin Installation and Set-Up Instructions

Step by Step Set Up Guide

OWNER S MANUAL. ezup.com. 13 x 13 (4.0m x 4.0m) 10 x 10 (3.0m x 3.0m) 16 x 16 (5.0m x 5.0m)

1. INTRODUCTION GENERAL INFORMATION WORKING PRINCIPLE CUTTING SECTION SPECIFICATIONS INSTRUCTIONS FOR USE 5

Advantage Plus TIM-3600 Series Reel

DO NOT USE WITH CROSSBAR SPREAD LESS THAN 24.

MAX Series 9514 OPERATOR S MANUAL

LVS BASE VEST OPERATOR S MANUAL

BERYL Service Guide. Travel Adjust OTT Change

Installation Instructions for the Rolltec Physique XL Awning

User Guide. Tripod. flowtech 75 Tripod. Part No. V

FEATURES & BENEFITS OF THE TOW PRO LITE :

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

ASSEMBLY & CARE INSTRUCTIONS

COPPER RIVER CABIN TENT

300 ft. 5/8 Hose wagon

VACATION'R A ROOM FOR VERTICAL ARM AWNINGS

FISH CAT SCOUT OWNER S MANUAL

10 X 20 X 8 Dome Canopy

Air2Care. Comfort & Pressure ulcer prevention PEČOVATELSTVÍ HEALTHCARE NURSINGCARE

ASSEMBLY & CARE INSTRUCTIONS. 7 x4 TRAILER TENT SERIES 4 9. OPTIONAL SUNROOM Wall and floor kit. OPTIONAL SPARE ROOM Roof, wall and floor kit

Read all instructions and warnings before using this fireplace. WARNING

JOINTED ARM AWNING SWINGLINE CASSETTE

ROOFBAG CAR TOP CARRIER INSTALLATION BOOKLET

PS-10 PS-12D PS-12. Primo Slicer Manual FOR OPERATOR-DO NOT DISCARD

PM-X IR SURGICAL POWER & ACCESSORIES

INSTALLER AND OWNER GUIDE

View slicer 800-S. meat pusher. handle. thumb. screw. sharpener. table release. handle. securety. screw. knifescraper

Thanks for shopping with Improvements! 10 Solar Lighted Gazebo Item #531753

Getting Started Guide

CONGRATULATIONS OPERATIONS ANTENNA (IF APPLICABLE) Congratulations on purchasing your Frontline Campervan.

AERODYNE RESEARCH CORPORATION RACE TRACK ROAD, TAMPA, FLORIDA, 33626, USA PHONE (813) FAX

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

Roller Bar End Cap (w/round Drive Shaft) Replacement Instructions for Vista and Motorized Awnings * Helpers needed *

User Manual. Zitzi Carseat pro

GEAR GUIDE CABELA S SET NUMBER:

Installation Instructions for the Rolltec Adalia X3M Extenda Awning

CREW REST MODULE CMM DESCRIPTION AND OPERATION

RETRACTABLE AWNING w/ OPTIONAL HOOD ASSEMBLY INSTRUCTIONS

Rooftop Tent Owners Manual

Air Mattress. Model No.: EAM-DQ1 & EAM DT1. Questions or Concerns? (855)

Transcription:

Bi Wave Carer User Guide LFT5104 Issue 5

Bi Wave Carer Use and Care Instructions The BI WAVE CARER System is suitable for patients showing any of the following characteristics: Assessed to be up to very high risk of pressure sore development. Require therapy to promote pressure sore healing. Have some mobility whilst in bed or are turned regularly. The BI WAVE CARER System reduces skin surface pressure at frequent intervals. This encourages the blood flow necessary to maintain healthy tissue, thereby preventing pressure sores even in the most vulnerable patients. The System also offers comfort for the patient and ease of use for the carer. Immobile patients or those not able to be turned frequently and therefore at greater risk can be nursed on the CAIRWAVE Therapy System.

BI WAVE CARER CONTENTS SECTION PAGE A GETTING STARTED 2 List of Parts 2 Setting Up 2 B PROFILING AND GATCHING 5 Profiling 5 Gatching 6 C MOVING THE BED AND POWER CUTS 7 D CPR (CARDIO PULMONARY RESUSCITATION) 8 E DEFLATION, REMOVAL, CARRYING AND STORAGE 9 Deflation 9 Removal 9 Carrying and Storage 9 F ALARMS AND FAULT FINDING 10 Alarms 10 Fault Finding 11 G CLEANING 11 H USER SERVICING AND SERVICE 12 I COVER REPLACEMENT 12 J TECHNICAL DATA 13 1

SECTION A GETTING STARTED LIST OF PARTS Check that all parts are present before assembling the system. Mattress and Cover Power Unit Airpipe SETTING UP The BI WAVE CARER system can be used on all standard hospital, domestic and profiling beds. To install the system, carry out the following procedure: 1. Lower the bed if possible. Remove the existing mattress from the bed frame. 2. Check that there is nothing to damage the mattress, such as sharp edges or springs. If your bed frame does not have a solid base the use of a fracture board or similar firm base is advisable to ensure maximum benefit. 3. Place the mattress on the bed with the airpipe at the foot of the bed. 2

4. Loosely secure the mattress to the moving parts of the bed frame using the straps provided. Do not fasten the straps to removable head or foot boards. 5. Hook the power unit over the foot of the bed or place on the floor if preferred. PUSH DOWN BUCKLE TO LOCK STRAP MATTRESS SECURING STRAPS* MATTRESS/AIRPIPE CONNECTOR POWER UNIT POWER LEAD FOR QUICK RELEASE OF BUCKLES PULL LOOSE END OF STRAP AWAY FROM BUCKLE CPR CONNECTOR * MAKE SURE THE SECURING STRAPS ARE ATTACHED TO THE MOVING PARTS OF THE BED FRAME ONLY. 6. Connect the airpipe to the mattress by lining up the outer pin and arrow on the locking ring, then aligning the inner pin and slot and pushing the two halves of the connector firmly together until a click is heard. LOCKING RING ALIGN OUTER PIN AND ARROW ALIGN INNER PIN AND SLOT. PUSH TOGETHER UNTIL A CLICK IS HEARD 3

7. Connect the airpipe CPR handle onto the power unit as shown, ensuring the PULL FOR CPR label is visible. 8. Plug the mains lead into a suitable electrical socket and switch the power unit on. The power switch, located on the right side of the power unit, will illuminate green to show power is on. The audible alarm will sound and the three front panel lights will flash on then off once to complete the self test phase. The amber light will flash and continue flashing while the mattress is inflating. 9. The system will take approximately 25 minutes to reach full inflation pressure, at which time the green NORMAL light will come on and the amber light will extinguish. During this start up phase the red FAULT light may come on and the audible alarm sound, if this occurs turn the power unit off and back on again to reset the alarm. Once inflated, check the securing straps and tighten if required. For maximum benefit, use only one sheet loosely placed over the mattress. If the sheet is tucked in ensure that it is left loose over the mattress to avoid hammocking. Once a patient is placed on the mattress the system will adjust automatically to the patient characteristics (weight/position) to provide optimum clinical benefit for each patient. The mattress may feel firm at first until it has adjusted to the individual. Allow approximately 15 minutes for this automatic adjustment to be completed. If the mattress does not perform as described above, please refer to Section F of this guide, Alarms and Fault Finding. 4

SECTION B PROFILING AND GATCHING The BI WAVE CARER system mattress can be used in a profiled position to provide pressure relief for patients sitting up in bed, and/or a gatching position for patients where the lower section of their bed is raised. CAUTION: Do not fasten securing straps to removable head or foot boards, this may impede their removal in an emergency. PROFILING (Sitting Up) If using a bed with a manually operated back rest, release the mattress securing straps, lift the head end of the mattress and adjust the back rest to the required angle. Move the mattress to the desired position and, using the centre and foot end straps, secure the mattress to the the moving parts of the bed frame. If using a bed with a powered/mechanical back rest, release the mattress securing straps and raise the back rest to the required position. Move the mattress to the desired position and secure to the moving parts of the bed ensuring the straps are positioned and fastened so they are not stretched or interfere with the bed mechanism when used in its various positions. DO NOT FASTEN STRAPS TO REMOVABLE BED HEAD SECURING STRAPS* * MAKE SURE THE SECURING STRAPS ARE ATTACHED TO THE MOVING PARTS OF THE BED FRAME ONLY. 5

GATCHING (Bending at the Knees) Release the mattress securing straps and gatch the knee section as required, being careful not to disturb the power unit by putting unnecessary strain on the airpipe. Move the mattress to the desired position and secure to the moving parts of the bed ensuring the straps are positioned and fastened so they are not stretched or interfere with the bed mechanism when used in its various positions. SECURING STRAPS * MAKE SURE THE SECURING STRAPS ARE ATTACHED TO THE MOVING PARTS OF THE BED FRAME ONLY. 6

SECTION C MOVING THE BED AND POWER CUTS WARNING: The patient will not receive the benefits of the BI WAVE CARER System while it is disconnected and the power unit is turned off. Therefore they should be reconnected as soon as possible once the bed has been moved to its new position. If you need to move the bed or carry out nursing procedures with the mattress still inflated (but static) or in the event of a mains power failure, then follow this simple procedure: 1. Disconnect the mattress from the power unit by turning the locking ring on the airpipe connector to line up the pin and arrow. 2. Push the locking ring so the pin and arrow move together and pull the two halves of the airpipe apart. 3. Turn off the power unit and unplug from the electrical socket. An audible alarm will sound to indicate unit is turned off. Cancel the alarm by pressing the alarm reset button on the power unit. 4. The mattress will remain inflated for over 24 hours. The bed can now be moved. 5. When the bed has been moved to its new location, reconnect the two halves of the airpipe, plug in the power unit to an electrical socket and turn the power unit on. LOCKING RING ALIGN PIN AND ARROW PULL LOCKING RING. ALLOW AIRPIPE TO COME APART 7

SECTION D CPR (CARDIO PULMONARY RESUSCITATION) In the event of cardiac arrest, disconnect the CPR handle from the power unit. The mattress will immediately begin to deflate, allowing cardio pulmonary resuscitation. PULL CONNECTOR TO RELEASE 8

DEFLATION SECTION E DEFLATION, REMOVAL, CARRYING AND STORAGE To deflate the mattress, follow these easy steps: 1. Turn off the power unit and unplug from the electrical socket. An audible alarm will sound to indicate unit is turned off. Cancel this alarm by pressing the reset button on the power unit. 2. Disconnect the airpipe from the power unit as detailed in the CPR Section of this manual. The mattress will immediately start to deflate. If you wish to deflate quicker, apply downwards pressure to the mattress and press out as much air as possible. REMOVAL 1. Roll the mattress from the head end, with the top surface inward, tucking in the loose straps until completely rolled. Lay the airpipe along the rolled mattress. AIRPIPE AIRPIPE 2. Unhook the power unit from the bed frame and coil the power lead for ease of storage. CARRYING AND STORAGE In order to help with carrying and storage of the system, a high quality carrying bag for the mattress and the power unit is available. Please contact your supplier for details. 9

SECTION F ALARMS AND FAULT FINDING ALARMS The BI WAVE CARER system is equipped with a sophisticated set of alarm functions. These alert the user to the status of the available mains supply and any mattress defect. In normal conditions with mains power available, the power unit turned on and the mattress fully inflated and alternating, the power unit mains switch and the green status light on the power unit front panel will both be illuminated. If there is a mains power failure or the power unit is switched off, an audible alarm will be heard and all the lights on the power unit and mains switch will go out. The audible alarm may be cancelled by pressing the reset button on the power unit. If the system develops a fault while in use, the red fault light will flash and an audible alarm will be heard. The audible alarm may be cancelled by pressing the reset button on the power unit, (if the alarm is cancelled in this way it will return after 30 minutes) or turning the mains power switch on the side of the power unit to the OFF (O) position and then back ON (1). NOTE: The red fault light may flash in a series of two, three or four flashes. This is to assist your supplier if contacted about the fault. SPRING LOADED BED HOOKS AIR INTAKE STATUS LIGHTS: GREEN - RUNNING NORMALLY AMBER - SYSTEM INFLATING RED - FAULT ALARM RESET BUTTON 10

FAULT FINDING SYMPTOM No lights on power unit Status light red and alarm sounding or alarming but no lights ACTION Check power unit is connected to the mains power supply and that the power unit switch is turned to the ON (1) position Turn the mains switch on the power unit OFF then ON again If the mains light does not illuminate, mains power to the power unit has been lost. Check that the power unit is connected to the mains supply and that the power unit switch is turned to the ON (1) position If the problem persists, contact your supplier. If the alarm clears then returns after 30 minutes, check air connection between power unit and mattress, ensuring that all air connectors are pushed fully home and the air pipe is not folded or bent causing air flow to be reduced. Turn mains switch on power unit OFF then ON again SECTION G CLEANING It is recommended that the system is cleaned regularly and after each patient use. The power unit and mattress can be cleaned using the following simple procedure: 1. Mattress and Cover Cleaning CAUTION: Do not high temperature Autoclave or use Phenolic based products for cleaning. In many cases it will not be necessary to remove the mattress from the bed prior to cleaning. a. Liberally swabbing with hot water containing detergent, then drying. b. Swabbing with a solution of sodium hypochlorite (up to 10,000 parts per million available chlorine), then drying. The mattress cover and airpipe cover can also be machine washed to a maximum temperature of 80ºC. To remove the cover and airpipe see Section I, Cover Replacement. 2. Power Unit Cleaning CAUTIONS: Ensure the Power Unit is turned off and disconnected from the mains supply before cleaning. Do not immerse the power unit while cleaning. The power unit can be cleaned by wiping down with a cloth dampened with one of the solutions in a. or b. above. The System may be decontaminated using ETO (Ethylene Oxide) or Draeger Method. For further information, contact your supplier. 11

SECTION H USER SERVICING AND SERVICE The BI WAVE CARER System has been designed for ease of use and contains no user serviceable items. If you have any queries about the operation of the system contact your supplier. If the system becomes defective during the warranty period, it will be repaired or replaced free of charge in accordance with the system warranty. To help us identify the system when telephoning, please make a note of the serial number which you will find on the label on the rear of the power unit or on the foot end of the mattress. Isolate from mains before removing cover. Unit contains no user serviceable parts. Only to be opened by qualified service personnel.! To remove the mattress and airpipe covers: SECTION I COVER REPLACEMENT 1. Fully unzip the cover and remove the top section. 2. Release the elasticated ends of the airpipe cover and remove by pulling the cover over the airpipe connector. 3. Undo the 6 clips securing the mattress to the bottom cover section, pull the airpipes through the sleeve in the cover and lift the mattress out of the bottom cover section. Replacement is the reverse of 1, 2 and 3 above with the following addition: 1. When fitting the airpipe cover, ensure the elasticated end fits fully over the retaining plate on the air connector. Loosely fit the strap around the internal pipes. 12

Cycle Control Cycle Time Supply Voltage Power Rating Fuse Rating Noise Level SECTION J TECHNICAL DATA Purpose designed distributor valve supplying operating air to the inflatable cells 12 minutes 220/240 Vac 50Hz 40 watts/40va 2A NC30 Nominal Dimensions Mattress (Inflated) Power Unit Length: 1900mm Height: 300mm Width: 900mm Width: 220mm Height: 240mm Depth: 130mm Weight: 8.1kg Weight: 2.7kg Electrical Safety Conforms to BSEN 60601-1 Classification Mode of Operation Symbols Class 2, Type B Continuous Alternating Current I O Mains Switch - 1 (On) Power connected to the mains supply 0 (Off) Power disconnected from mains supply Class 2 Type B Environment (Usage and Storage) EMC Air Humidity: 10% to 85% Ambient Temperature: -10 C to +60 C This equipment complies with EMC requirements. If effects are noticed the affected equipments should be moved apart. This product carries the CE mark in accordance with EC Directive on Medical Devices (93/42/EEC). Pegasus Limited cannot be held responsible for any damage caused to our products (by foreign objects needles, sharps, eating utensils, etc) other than due to normal wear and tear as defined in the product warranty agreement. Nor for any injury or incident which relates to the use of cot sides, profiling or any other mechanical or electrical device used in conjunction with this product unless supplied and/or manufactured by Pegasus Limited. 13

NOTES

NOTES

PEGASUS LIMITED Pegasus House Waterberry Drive Waterlooville Hampshire PO7 7XX England Tel: +44 (0) 23 9278 4200 Fax: +44 (0) 23 9278 4250 E-Mail: custserv@pegasus-uk.com Website: www.pegasus-uk.com PEGASUS and the associated device marks are Trademarks of Pegasus Limited. Pegasus Limited has a policy of continuous product improvement and reserves the right to amend specifications presented in this brochure. ISO ISO 13485 9001 UKAS QUALITY ASSURED FIRM QUALITY ASSURED FIRM BRITISH HEALTHCARE BHTA TRADES ASSOCIAT ION LFT5104 Issue 5 Pegasus Limited 2003