Instructions for Use A-dec Quick-Disconnect Syringes

Similar documents
Gas Go Anywhere /23/01

Solera Classic Awning

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

INSTALLATION GUIDELINES

300 Model 870 Four Wheel Hose Cart Owner s Manual

Urea/Adblue Hose Reel

Advantage Plus TIM-3600 Series Reel

Installation Guide. Single-Control Kitchen Sink Faucets

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

Wenger Corporation 2014 Printed in USA 05/14 Part #049B015-09

GoBidet Bidet Attachment

Genesis. Side Burner Accessory Installation. Step 3. Step 1. Step 2. For use with Genesis Gas Barbecues Only

FLAIR TWO-HANDLE BATH & SHOWER FAUCET

Operating Instructions

Model 698/ and Model in 1 Hose Reel Owner s Manual

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System

Clik X Anchor. Directions for Use REV C

PL500A Platform Extension

DIAMOND TECH INTERNATIONAL Innovations For Creativity DIAMOND LASER BAND SAW OPERATIONS MANUAL

Oletto Single Handle Commercial Style Kitchen Faucet

Operating Instructions

Otter Pro XT Cabin Installation and Set-Up Instructions

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

LDR Brachytherapy Seed Sterilization and Sorting Tray

42-YP Series. Serie 42-YP Série 42-YP. Single Control Lavatory Faucet Grifo Monomando para el Baño Mitigeur de Robinet pour Lavabo

AFC-50 Automatic French Fry Cutter Instruction Manual

Tidland Series 'C' Knifeholder MAINTENANCE MANUAL Crush Cartridge Class I, II, III Crush Slitting

Application Tooling Specification

Hose Reel Series L701/G701

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

FORM (Apr. 2006)

Capri. Instruction Manual. Balcony Umbrella x 6.93 Rectangle / SSBU-5X7RT5T

VEPR Round Drum Disassembly and Assembly

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

Otter Pro X-Over Lodge Installation and Set-Up Instructions

Installation and User s Manual 12 x 10 MOTORIZED AWNING

NEWMAR SERVICE SCHOOL

FISH CAT SCOUT OWNER S MANUAL

TWISTLOCK VEHICLE STABILIZER (TVS) SYSTEM INSTRUCTIONS

VISIT OUR WEBSITE: OR CALL US TOLL FREE AT

Otter XT Cabin Installation and Set-Up Instructions

INSTALLATION INSTRUCTIONS TOWNSEND

Contents. Awnings USA - Full Protective Hood Manual Instructions ft 11" - 11ft 6" Awnings

Ceramic Probe Replacement Instructions Accessory G

For the diagnosis of Hirschsprung s Disease

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

Otter Pro XT 1200 Cottage Installation and Set-Up Instructions

Oletto Single Lever Commercial Style Kitchen Faucet

31 Series. Serie 31 Série 31. Two Handle Kitchen Faucet Grifo Con Dos Manijas Para Cocina Robinet De Cuisine À Avec Deux Poignées COMPANY

APPENDIX A LIGHT SOURCE

Tools. For safety and easy faucet replacement, San-Ei recommends the use of the following helpful tools:

B-0107-C REPAIR PARTS KIT

Otter XT 650 Cabin Installation and Set-Up Instructions

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

FORCE 10 MARINE BARBEQUES

MAX Series 9514 OPERATOR S MANUAL

Globe Slicer Safety Tips

Assembly Manual. OLM Retractable Canopy for 12X20 Breeze Pergola by Outdoor Living Today. Revision #11 October 5, 2017

Kauai III ShowerSpa MODEL # 1011-III-CH, 1011-III-BN, 1011-III-ORB GENERAL DESCRIPTION PRODUCT FEATURES SPECIFICATIONS

GLM300 Semi-auto Slicer

PRODUCT MANUAL - M096

Primrose Awnings - Standard Manual Instructions

Retractor Kit Rev: D. Instruction For Use NEXT ORTHOSURGICAL 3270 CORPORATE VIEW, SUITE A VISTA CA /1/14

Tidland External Element Shaft

Blue Series Hot Melt Hose with RediFlext II Hanger System

The Cove Fire Pit. Installation Instructions for CV-30

Service Bulletin HHXDF5 Mechanical Ride-On Trowels LPG Hose Replacement

Crespo Single Lever Pull Down Kitchen Faucet

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

Instructional Booklet

How to Set up Your Configurable (Home and Camping) Stir Fry Stove

PM-X IR SURGICAL POWER & ACCESSORIES

Accu-Chart TM Healthcare Systems, Inc.

CRD120SC TUBING CUTTER

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles

Two Piece Low Torque Kelly Valve

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

STEALTH PRO OWNER S MANUAL

Assembly Manual. OLM Retractable Canopy for 10X12 Breeze Pergola by Outdoor Living Today. Revision 13 October 3rd /2017

User s Manual Trampoline 8

RUPHIS Blade Clamp. Instruction Manual

JARVIS. Model 70 Airsnip Air Powered Scissors

Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves

Home Care for Your Gravity Fluid Drain

Solera Classic Awning OEM INSTALLATION MANUAL

Swagelok Thermoplastic Hose Hand Swager User s Manual

accidents which arise due to non-observance of these instructions and the safety information herein. CAUTION:

Mateo Single Lever Pull Out Kitchen Faucet

Roller Bar End Cap (w/round Drive Shaft) Replacement Instructions for Vista and Motorized Awnings * Helpers needed *

Oletto Single Lever Pull Down Kitchen Faucet

TRAVEL-SMART AWNING SERIES »LYRA 4 « Family Tent. Model No. HW Document-No.: HW Issue: August Top Quality Camping

Hike Water Microfilter GB DE FRA NL DK SWE NOR FIN IT ESP POR RUS

Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual

Professional Series Galley Range

LEG KIT. Pizza Oven OWNER S MANUAL. For 6000 Series Portable Ovens

Important! Read all of these instructions before assembling or riding the glider. For questions or help please call Glide Bikes at

Corning Aspirator Instruction Manual

INSTRUCTION SHEET TWISTLOCK VEHICLE STABILIZER (TVS) SYSTEM PN S: , ,

AND LOAD CANOPY RACK SPECIFICATIONS

INTRODUCTION. It is recommended that these instructions are read in conjunction with the torque wrench and pump operating instructions.

Transcription:

Instructions for Use A-dec Quick-Disconnect Syringes Contents Basic Operation...1 Adjustments... 4 Asepsis... 6 Specifications, Warranty, and Product Service... 8 Basic Operation Water, Air, and Spray Functions Use the buttons to control water, air, and spray functions. For spray, press both buttons simultaneously. Water Air 85.0680.00 Rev AG

A-dec Quick-Disconnect Syringes Instructions for Use Syringe Tip A-dec syringe tips have three locking grooves, which hold the tip in place when properly installed and prevent ejection of the tip during use. The tips are marked with the A-dec a. Syringe Tip Retainers A-dec syringes come with a standard non-locking syringe tip retainer assembly. A locking retainer assembly can be purchased as a separate option. Non-locking Retainer Locking Retainer WARNING Use only A-dec syringe tips in A-dec syringes. A-dec syringe tips have been engineered and manufactured for use with A-dec syringes. Using syringe tips manufactured by a company other than A-dec may result in syringe tip ejection. Tip ejection may result in ingestion or aspiration of the tip, requiring immediate medical attention. Non-locking Retainer The non-locking syringe tip retainer, identified by its smooth surface, allows for easy syringe tip removal and installation. It also allows the syringe tip to rotate to spray in different directions. NOTE Because the non-locking retainer assembly allows the syringe tip to rotate, it should not be used as a cheek retractor. Optional Locking Retainer The locking retainer has a hex-shaped exterior that allows the retainer to be tightened, preventing the tip from easily rotating. The tip can then be used for cheek retraction. 2

Install the Syringe Tip WARNING If you do not feel two clicks as you install the syringe tip, do not use the syringe. The O-rings inside the syringe tip retainer assembly are damaged and may allow the syringe tip to be ejected. Replace the O-rings before using the syringe. 1. Push the syringe tip into the retainer assembly until you feel two clicks. Remove the Syringe Tip 1. If you have a locking retainer, loosen it. 2. Pull the tip straight out of the syringe to remove it. Restrict the Tip Rotation (With a Locking Retainer Only) If you use your syringe tip for cheek retraction, you must restrict the tip rotation. CAUTION Tightening the locking retainer on an improperly installed syringe tip crushes the internal collet, making removal of the syringe tip difficult and installation of a new tip impossible. Complete Installation (no groove showing) Incomplete Tip Installation (groove showing) 1. Use the plastic wrench to tighten the locking retainer. NOTE The wrench is designed to be sterilized. For instructions, see Asepsis on page 6. 2. Ensure that the tip does not rotate easily. CAUTION The syringe tip may eject if it is not fully seated resulting in damage to the tip. Quick Disconnect Syringe Terminal The quick-disconnect terminal allows you to remove a syringe from the delivery system without turning the system off. 2. Point the syringe at the floor and press the air button several times to be sure the tip is properly installed. 85.0680.00 Rev AG 3

A-dec Quick-Disconnect Syringes Instructions for Use Adjustments Air and Water Flow Adjustments to the air and water flow are made with a pinch valve or a control valve. Use the table below to identify the location and adjustment method for your delivery system or assistant s instrumentation. Model A-dec 300 delivery systems A-dec 500 (version A) delivery systems Performer delivery systems A-dec 351 assistant s instrumentation A-dec 500 assistant s instrumentation Radius 7115 assistant s instrumentation A-dec 352 and 353 support-side assistant s instrumentation Radius 7285 assistant s instrumentation Cascade 4635 assistant s instrumentation Performer assistant s instrumentations Cascade delivery systems Decade delivery systems Location of Flow Control Control head Lift arm of chair Support center Control head Method of Adjustment Pinch valve Pinch valve Pinch valve Flow control valve on the control block Adjust the Flow with a Pinch Valve 1. Turn the adjustment screw for the water tubing clockwise to reduce the water flow, or counterclockwise to increase the flow. 2. Turn the adjustment screw for the air tubing clockwise to reduce the air flow, or counterclockwise to increase the flow. 3. Press both syringe buttons to test the spray. Red Tubing (water) Adjustment Screws Yellow Tubing (air) NOTE If your product is not listed, contact your authorized A-dec dealer for more information. 4

Adjust the Flow With a Flow Control Valve 1. Turn the top flow control valve clockwise to decrease water flow, or counterclockwise to increase water flow. 2. Turn the bottom flow control valve clockwise to decrease air flow, or counterclockwise to increase air flow. 3. Press both syringe buttons to test the spray. Troubleshooting Use the following troubleshooting table to identify and solve problems with the syringe. Problem Possible Cause Action Syringe leaks air or water from a button. Faulty O-rings on the button. Replace the button assembly (p/n 23.1234.00). Water Flow Control Valve Syringe tip drips when the syringe is not in use. Faulty O-rings on the water button. Replace the water button (p/n 23.1234.00). A short burst of water sprays from the tip when the air button is pressed. Improperly installed or damaged syringe tip. Pull out and reinstall the syringe tip correctly. Replace the syringe tip if it still leaks. (p/n 23.0872.01) Air Flow Control Valve Warm Water Syringe Temperature Adjustment If you have the optional warm water syringe and would like the water temperature adjusted, contact your authorized A-dec dealer. Water or air leaks from the syringe handle. Air leaks from the top of the tip retainer assembly. Syringe handle is not tightly connected to the syringe. O-rings on the terminal are damaged. Syringe tip is damaged. Tighten the syringe handle onto the syringe. Replace the O-rings (p/n 030.002.02) on the terminal and lubricate with A-dec silicone lubricant. Replace with a new tip (p/n 23.0872.01). Retainer internal O-rings are damaged. Replace the two inner O-rings (p/n 035.062.00) of the retainer assembly. Syringe tip is difficult to install. Retainer internal O-rings have been lubricated with a petroleum-based lubricant. The tip retainer assembly has been damaged. Replace the O-rings (p/n 034.003.01) and remove remaining lubricant from the retainer. Use A-dec silicone lubricant on the new O-rings. Replace the tip retainer assembly (non-locking p/n 23.1112.00/ locking p/n 23.1090.00). 85.0680.00 Rev AG 5

A-dec Quick-Disconnect Syringes Instructions for Use Troubleshooting (continued) Problem Possible Cause Action Water leaks from the base of tip retainer assembly. Syringe tip is loose in the retainer assembly. Asepsis Tip is not fully installed. Small O-ring in the retainer assembly has failed. A non-a-dec syringe tip is in use. Retainer O-rings are worn or damaged. Push tip completely into place with the third groove hidden. Replace the O-ring or replace the retainer assembly (p/n 034.003.01). Replace with an A-dec syringe tip (p/n 23.0872.01). Replace the O-rings (p/n 035.062.00). A-dec syringes are considered a noncritical item. Use single-use barriers or a hospital disinfectant to disinfect the syringe between each patient or when the barrier has been compromised. A-dec syringes are designed to withstand steam sterilization that may be used instead of or in addition to barriers and disinfectants. All syringe tips are considered semicritical items and must be sterilized after each use. A-dec has designed the syringe tips to be autoclavable or heat sterilized. Remove the syringe and syringe tips from the delivery system for sterilization. Disconnect the Syringe 1. Unscrew the syringe handle until the syringe head separates from the syringe terminal. When the syringe is disconnected, any water remaining in the syringe head drips out. Preclean the Syringe Tip 1. Remove the tip from the syringe. 2. Immerse the tip in a holding solution until it is ready for ultrasonic cleaning. Clean the Syringe and/or Syringe Tip Manual 1. Gently brush the syringe threads with a nylon or brass bristle brush. 2. Use an irrigating syringe with clean water to flush the lumens of the tip. 3. Rinse the syringe and syringe tip with clean water. 4. Remove excess water and allow to dry before sterilizing. Ultrasonic Bath 1. Use a general purpose or enzymatic detergent. 2. Follow instructions provided by ultrasonic bath manufacturer and detergent manufacturer for processing time. 3. Rinse the syringe and syringe tip with clean water. 4. Remove excess water and allow to dry before sterilizing. Automated Washer/Thermal Disinfector CAUTION The use of automated washers and thermal disinfector is not recommended as it may damage the syringe and syringe tip finish. The processing of dissimilar metals may also lead to tarnishing of instruments Disinfect 1. Flush the tips with isopropyl alcohol. 6

Package Instruments should be packaged in a sterilization wrap or pouch to maintain sterility unless the instruments are to be used immediately after sterilization. For specific use requirements, refer to the instructions for use that accompany the sterilizer and the sterilization packaging material. The use of sterilization indicators or integrators is recommended. Sterilize 1. Heat sterilize the syringe and syringe tip using a steam autoclave for the following: Gravity Displacement 30 minutes at a dwell temperature of 250 F (121 C). Dynamic-Air-Removal 4 minutes at a dwell temperature of 273 F (134 C) 2. Allow the pack to cool and dry before removing from sterilizer to prevent cross contamination. Storage Store in a dry and dust free location. Do not store with non-sterile instruments. See the sterilization packaging manufacturer s instructions for use to determine how long sterility can be maintained. Test Before using a syringe and syringe tip that have been sterilized, test the syringe to ensure the tip does not eject from it. Maintenance The syringe is designed to be easily serviced in the operatory. The syringe parts subject to wear under normal use are provided in a syringe repair kit available from your authorized A-dec dealer. Proper care and maintenance of your A-dec syringe is critical to ensure the safety of your patients and the reliability of this precision instrument. A-dec Silicone Lubricant Use only A-dec silicone lubricant to lubricate the syringe button assemblies and the O-rings in the syringe tip retainer assembly. CAUTION The use of petroleum-based lubricants (jellies, creams, or lotions) cause the O-rings in the syringe to swell and/or deteriorate, resulting in syringe malfunction or failure. A-dec Replacement Parts A-dec replacement parts have been precisely designed for your A-dec syringe to ensure that the syringe functions properly. A-dec recommends you replace the two internal O-rings (p/n 035.062.00) and the small O-ring (p/n 034.003.01) in the syringe tip retainer assembly at least once a year. Lubricate the O-rings with A-dec silicone lubricant (p/n 98.0090.01) when you replace them. 85.0680.00 Rev AG 7

Recommended Tools Use the wrench (p/n 98.0900.00) from the kit (p/n 23.1090.00) to torque the locking retainer (p/n 23.1103.00). Use the adaptor (p/n 23.1354.00) to torque the non-locking retainer (smooth retainer, p/n 23.1111.01). Specifications, Warranty, and Product Service Minimum Air and Water Requirements Air: 2.50 scfm (70.80 l/min) at 80 psi (551 kpa) Water: 1.50 gpm (5.68 l/min) at 40 psi (276 kpa) Small O-ring Internal O-rings IMPORTANT For additional specifications, identification of symbols, warranty, and other regulatory requirements, see the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a-dec.com. NOTE Specifications are subject to change without notice. Some requirements may vary from country to country. For more information, contact your authorized A-dec dealer. Product Service Product service is available through your local authorized A-dec dealer. For service information, or to locate an authorized dealer, contact A-dec at 1.800.547.1883 in the USA and Canada or 1.503.538.7478 worldwide, or visit www.a-dec.com. A-dec Headquarters 2601 Crestview Drive Newberg, Oregon 97132 United States Tel: 1.800.547.1883 within USA/CAN Tel: +1.503.538.7478 outside USA/CAN Fax: 1.503.538.0276 www.a-dec.com A-dec Australia Unit 8 5-9 Ricketty Street Mascot, NSW 2020 Australia Tel: 1.800.225.010 within AUS Tel: +61.(0).2.8332.4000 outside AUS A-dec China A-dec (Hangzhou) Dental Equipment Co., Ltd. 528 Shunfeng Road Qianjiang Economic Development Zone Hangzhou 311106, Zhejiang, China Tel: 400.600.5434 within China Tel: +86.571.89026088 outside China A-dec United Kingdom EU Authorized Representative Austin House, 11 Liberty Way Nuneaton, Warwickshire CV11 6RZ England Tel: 0800.ADEC.UK (2332.85) within UK Tel: +44.(0).24.7635.0901 outside UK ÍuÈ.Ç&pÈ.00uÎ 85.0680.00 Rev AG Copyright 2018 A-dec Inc. All rights reserved. IFUself5