Why measure average air speed in a tunnel ventilated house?

Similar documents
MODEL CFD Forward Curved Belt Driven Inline Duct Blower

CESSNA SKYMASTER 337

Industry best 5 year fan housing warranty, 1 year motor warranty

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

TRANSFER OIL. thermoplastic and ptfe hoses fittings and assemblies

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

Squirrel Cage 3-Phase Induction Motor TS21F-II SERIES

Cross Folder AF-76 series. AF-76 series. Cross Folder AF-764AKLL/764AKL/762KLL/762KL. Accurate Cross Folding with Easy Operation

Introduction of Interlining P. 2

Maintenance and care of the. German Red Clipper and its blades

CentroPelet Z8,Z12,ZR12 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation of pellet stove

1224 Splitter and CTO combo, setup instructions using the Panelview HMI

SMART BIO-ETHANOL ELECTRONIC BURNER

ECLIPSE 500. Aircraft Overview. Do Not Use For Flight

ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O

WISH NEBRASKA INC CUSTOMER : LOCKWOOD TOWER FT SYSTEM PSI AT TOP OF PIVOT

Load-following capabilities of Nuclear Power Plants. Erik Nonbøl

PELLET STOVES AND INSERTS

EB300. Ethanol Burner. User s Manual Installation Instructions

Assembly instructions for Eurotramp trampolines Series: Ultimate, Grand Master Exclusiv, Grand Master, Master

Outdoor Clothing: The Layering System

Robin DR400/140 G-BAGR. Check-list

Spiral Duct. Contents. Introduction 1. Duct & Fitting Range 2. Duct Sizes 3. Fittings 5. Round Duct Connector 7. Installation 8

YMA TRAINING CATALOG 2017

Flammability of Interior Materials

Back to the Basics. Internal Pullers. What Are Internal Pullers?

» AQUILA 320(HIGH TOP) «

Design Guide. No. 160, 8/1/05. AirHeat Burners. AH-MA Series. Version 2

TYPES OF PASSENGERS WITH SPECIAL NEEDS. Passengers with reduced mobility. These in turn are divided into three categories:

Cutting Edge Turnout Gear That Combines Combat and Sports Technology For Outstanding Performance & Fit V-FORCE

CASM electric cylinders

DOC Air Force One Installation Manual REV 002

Contents. Awnings USA - Full Protective Hood Manual Instructions ft 11" - 11ft 6" Awnings

Product information Truma VarioHeat and E-Kit. July 2018

SHOWPIG 101. Presented by Kelly Morgan, Manager of OH-PIGS Circuit Junior Ohio Pork Ambassadors Katie Seigel and Gus Mitchem

SECTION I-1. Type: 1812-AC. Fuel: Air-Gas.

DEMV-MF2 DEP-MFP. Horizontal Lathes. Heavy Duty Machines

787 Design for Maintainability

TRAVEL-SMART AWNING SERIES »LYRA 4 « Family Tent. Model No. HW Document-No.: HW Issue: August Top Quality Camping

Packed to perfection. FAST, FUNCTIONAL AND FLEXIBLE For industrial self-generation, small utilities, industrial and IPP customers who do not

Load-following capabilities of nuclear power plants

You recognize it immediately. The shape, the name, the quality. The Harman. P-Series gives you the heat you want when you want it.

CESSNA 400 EQUIPPED WITH GARMIN G1000

Production Work Instruction

½ SkyBean ChaseCam user guide (rev. 1803)

CE 563 Airport Design

Assembling & Fitting Instruction August 2015

Stûv 22. Aligning fire and architecture

Air inlet. 1. Drilled Pipe - Typically drilled pipe uses more compressed air while producing inconsistent flow at high noise levels.

WEIGHT, BALANCE & EQUIPMENT LIST

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW

STUDY OF EFFECTS OF VIBRATION ON GRIP STRENGTH

UAS to GIS Utilizing a low-cost Unmanned Aerial System (UAS) for Coastal Erosion Monitoring

Apply for further information to the manufacturer, if you ve got additional questions after studying this manual.

PEAK 1 GENERAL INFORMATION 1.1 THE CONCEPT 1.2 SAFETY 1.3 THE SPEED SYSTEM 2 THE EMERGENCY PARACHUTE 2.1 EMERGENCY PARACHUTE ASSEMBLY

STEM FUTURES. Air Travel STEM. Works! Using Maths Tasks. About the Industry. About Your Task

MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

High Speed Centrifuge. LHS-A, B Series

GTZ SUN E Project. Water Boiling and Field Test Results Of Institutional Rocket Stove (Draft) Ethio Resource Group Pvt. Ltd. Co.

Gas Conversion Kits and Instructions

Temporary Structure/Use Checklist

ASSET MANAGEMENT AND AUTOMATION: ANDRITZ DIGITAL SOLUTIONS AND CASE STUDIES

EXTERNAL DIMENSIONS. L Length Kg W Width Kg D Depth. W Width. D Depth. 0 Kg Lid lt Base EXTERNAL DIMENSIONS.

SASP Advisory Committee Meeting #3

PRODUCT PRESENTATION R-BUS. The great traveller

S P E C I F I C AT I O N S

Geotech Portable Bladder Pumps Installation and Operation Manual

PREFLIGHT CHECK LIST COCKPIT PREPARATION

China Aeromodelling Design Challenge. Contest Rules China Aeromodelling Design Challenge Page 1 of 14

Parts Lists. Parts List Index. Using the Parts Lists

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

SOLHARO ASSEMBLY & INSTALLATION INSTRUCT IONS

ISO - Standards ISO 6940; 1995 ISO 6941; 1995 ISO ; 1987

PortMiami Director and CEO Juan M. Kuryla PUBLIC-PRIVATE PARTNERSHIPS (P3)

Integrating Life-Cycle Solutions for Maximum Return on Investment

B 600. Automatic grinding and polishing machine

4.2 Assembly Instructions

EA-12 Coupled Harmonic Oscillators

RM 2125 Troubleshooting Guide

FSXmap.com. Interactive Airport and Runway map for Flight Simulator X

Guida rapida di utilizzo Guía Rápida de Uso Guia Ràpido de Utilização Quick Start Guide Mode d emploi rapide FL-F60 MTL

49 CFR PART 571 FMVSS No. 302 FLAMMABILITY OF INTERIOR MATERIALS

Daily Estimation of Passenger Flow in Large and Complicated Urban Railway Network. Shuichi Myojo. Railway Technical Research Institute, Tokyo, Japan

Sun awning V225 Porto

QCC ACTION PLANNING IN 2004

A350 XWB Programme Update

HANDLING. Doc. No.: TKO AS3 Addendum 1 Revision: 0 Page: 2/10 SHORT INSTRUCTIONS FOR THE USE OF SWAGED ROTARY DRILLING AND VIBRATOR HOSES

AVAILABLE NOW NEW HIGH-QUALITY 341,871 SQ FT INDUSTRIAL/LOGISTICS BUILDING METRE CLEAR HEIGHT MINUTES TO M25/LONDON

LM 80 Test Report NS2L157AR H3

Installation & Commissioning Report

Operation Manual SUPER BEAST Multi-tool SC-11M-10

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

Content of Description

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

Troubleshooting Guide

Heathrow s Blueprint for noise reduction. Ten practical steps to cut noise in 2016/17

User Manual. 1000W Stackable 1.2 Cu. Ft. Commercial Microwave. Model: 180MW112T 05/2017. Please read and keep these instructions. Indoor use only.

Design Exploration of Low-Speed Wind Tunnel for Improved Flow Characteristics with STAR-CCM+ and Optimate+

W20 Containerized Power Plant

Transcription:

How To... A Tunnel Ventilated House Why measure average air speed in a tunnel ventilated house? The speed that air moves down the length of a poultry house determines the level of cooling that the birds in the house feel by creating a wind-chill effect. Incorrect air speed may either cause over heating (air speed too low) or chilling (air speed too high) of the birds. Regular measuring and monitoring of average air speed enables the effectiveness of the ventilation system to be evaluated and helps to identify any problems that may exist. 01 Why measure average air speed in a tunnel ventilated house?

Procedure for measuring average air speed in a tunnel ventilated house Air speed can be measured at any time during the flock, but ideally at least once per month (for broiler breeders) or once per cycle (for broilers). Air speed should also be measured as part of a program to diagnose ventilation problems. Equipment 1. An air speed meter - ideally able to measure average air speed. Procedure Step 1 Test the house in tunnel ventilation mode while the fans are running. Step 2 Ensure all side wall inlets are completely closed. Air should only be drawn in through the tunnel inlets and extracted through the tunnel fans. Procedure for measuring average air speed in a tunnel ventilated house 02 Step 3 Air speed measurements should be taken approximately 30 m or 100 ft away from the tunnel fans in 3 or 4 locations across the width of the house. In breeder houses, air speed must also be measured from on top of slats if they are in place, as air movement is more restricted in these areas. Tunnel fans Approximately 30 m or 100 ft = suggested area to take average air speed Step 4 Turn on the air speed meter and ensure that it is set to measure average air speed. Step 5 Hold the air speed meter at arms-length in front of you and away from any obstructions such as feeders or nest boxes. Step 5

Procedure for measuring average air speed in a tunnel ventilated house Step 6 Allow the meter reading to settle, registering a constant air speed. Step 7 Repeat Steps 1 to 6 for each location across the house. Average air speed will be calculated automatically when using the average air speed setting on the air speed meter. If no average reading is available: a. Record air speed at each location. b. Add the readings together. c. Divide the total by the number of locations where a reading was taken. This will give average air speed. Note When moving between measurement points, stop the air speed meter from taking any recordings by placing your hand over the anemometer. 03 Procedure for measuring average air speed in a tunnel ventilated hosue

The actual average air speed recorded in the house should be compared to the expected average air speed down the length of the house (see calculation below). Example for calculating expected air speed : In a house which is 2.1 m (7 ft) high and 14 m (46 ft) wide where 2 fans with a capacity of 35,000 cubic meters per hour (m 3 / hr) or 20,600 cubic feet per minute (ft / min) are running, expected air speed is calculated as: Metric [meters per second (m / s)] = Capacity of fans working Cross sectional area of house 3600 = (2 x 35,000 m 3 / hr) (2.1 x 14 m) = 0.66 m / s 3600 Imperial (ft / min) = Capacity of fans working Cross sectional area of house = (2 x 20,600 ft 3 / min) (7 ft x 46 ft) = 129.8 ft / min Note - When full tunnel ventilation is operating, the target air speed should be 2.5-3.0 m / s (492-590 ft / min). 04

HOW TO... If the measured average air speed is lower than that expected and / or, birds are showing signs of heat stress (panting, listlessness, drooping wings); Re-take the average air speed reading and if it is correct the following should be considered: Has the calculation for determining expected air speed been done correctly; check that the values used in the calcuation (fan capacity and house area) are correct. Are the fan louvers open completely? - This is a good indication of whether or not tunnel inlets are open wide enough. An example of fan louvers that are completely open. Are the fan belts, bearings and pulleys worn? An example of a worn fan belt. Is the static pressure in the house correct? (See Ventilation How To 02 - How To...Measure House Air Tightness). If there are no issues in any of the areas given above, turn on another tunnel fan and / or the cooling pads or house fogging system if available. Leave the house and birds to settle and re-evaluate after 20-25 minutes. If measured air speed is higher than expected and / or birds are huddling together with little movement; Has the calculation for determining expected air speed been done correctly; check that the values used in the calculation (fan capacity and house area) are correct. Is the static pressure in the house correct? (See Ventilation How To 02 - How To...Measure House Air Tightness). Are there too many fans running? Is the cool pad / fogging system working correctly? Is the water pump on for too long? If there are no issues in any of the areas above, turn off a tunnel fan and / or the cooling pads or house fogging system if available. Leave the house and birds to settle and re-evaluate after 20-25 minutes. Re-take the average air speed reading and if it is correct, the following should be considered: