Off-Site Solutions. CPM Headwalls. Concrete for Life

Similar documents
Shallow IC of 5

The most extensive Shower Tray Collection OPTIMUM CLASSIC LOW PROFILE RESINLITE SOLUTIONS

YCU 750 TU Unitized Curtain Wall System

TENDER NO. T WESTDALE ROAD SANITARY SEWER UPGRADE ADDENDUM NO. 1

Phantom Retractor System Overview

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

CertainTeed. Access Covers and Gratings. REXUS Manhole Covers

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Clay Adaptors & Insert Stove Kits

X-SERIES 10x10 SETUP INSTRUCTIONS

DRAFT. Dorabelle Campground Rehabilitation

Third Parties/Crossing

INTRODUCTION. Mailing address: Burke County Community Development Attn: Tim Johnson P. O. Box 219 Morganton, NC

CorriPipe. Fittings & Accessories

Green Washrooms. Certified Environmentally Preferred Products. Licence number UK / 4 / 002

Glenview Park District Policy and Procedure Manual Section _ - [Section Title] Soccer Goal Safety and Education Policy Pol. #

Permeable RECREATIONAL TRAILS

ADVANCED WARNING SYSTEM FOR SHARED USE CROSSING ON HOWARD STREET EAST OF NORDICA AVENUE

WAIPU COVE RESERVE BOARD POLICY DOCUMENT ANNUAL SITE DEVELOPMENT REGULATIONS

GREAT BRITISH BLADES MANUFACTURED IN SHEFFIELD, ENGLAND

September Standard recognised by Global Sustainable Tourism Council

HANDLING. Doc. No.: TKO AS3 Addendum 1 Revision: 0 Page: 2/10 SHORT INSTRUCTIONS FOR THE USE OF SWAGED ROTARY DRILLING AND VIBRATOR HOSES

TIMBER BOLLARDS TYPE I. TYPE ll TS mm Radius 150 x 100 white painted Timber post dia Timber Post. Ground Level NOTES:

Helping you work safely. Many industrial applications. Safety in design

Warehouse case study. Cargo Facility, Stansted. 35 million, transit warehouse cargo facility pre-let to Federal Express at Stansted Airport

CERTIFICATE OF APPROVAL No CF 5631 JOTUN A/S

4-wheeled container systems. The LARGE family

INSTALLATION INSTRUCTIONS for folding arm awnings

TECHNICAL DATA SHEET EZE Hub Shoring System

Primrose Awnings - Standard Manual Instructions

FINAL REPORT Papplewick Playing Field Skate Park Project

Picnic Units A picnic unit is a part of a picnic area

Member of the BPW Group HESTAL CARGOMASTER STRAP LIFT SYSTEM AID FOR LOAD SECURING

APPENDIX D: SUSTAINABLE TRAIL DESIGN. APPENDICES Town of Chili Parks and Recreation Master Plan Update

Contents. Company Background FLOWSTOPPER Plugging Device Kit and Replacement Parts Key Features & Benefits... 4

CAPABILITY STATEMENT TRANSPORT

Installation Instructions for the Rolltec Adalia X3M Extenda Awning

PERMA SKIRT AGAINST SEA LICE!

S-SERIES 10x10 SETUP INSTRUCTIONS

CERTIFICATE OF APPROVAL No CF 5303 CONTEGO INTERNATIONAL INC.

Installation Instructions for the Rolltec Physique XL Awning

75mm High Road Humps. Traffic Advisory Leaflet 2/96 April 1996

Hospital Link Project Project Update September 2015

Agenda Report. Spruce Street Outlet Drainage Improvements Tower Road Relief Sewer

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Sustainable Procurement Policy for Heathrow Airport Limited

Supersedes: AD3V (991) AD3V (1294)

Spiral Duct. Contents. Introduction 1. Duct & Fitting Range 2. Duct Sizes 3. Fittings 5. Round Duct Connector 7. Installation 8

1. PROJECT BACKGROUND. June 25, Alberta Transportation Central Region #401, Street Red Deer, Alberta T4N 6K8

Step by Step Set Up Guide

Sunshine Coast Council Locked Bag 72 Sunshine Coast Mail Centre QLD Submitted via online portal. 2 June 2017.

Tents and Air Supported Membrane Structures

85 Heart Lake Road South Brampton, Ontario, Canada L6W 3K2 Phone: Fax:

LOAD SECURING. CarFix - Car transportation safety. Protected label. Printable strap controller

WASTE + WATER MANAGEMENT AUSTRALIA OCTOBER 2015 V42.3 ENVIRONMENT SUSTAINABILITY PUBLIC HEALTH SINCE 1973 PRINT POST APPROVED

Amended Maintenance Dredge Spoil Management Plan. Shute Harbour Marina Resort

Poly Shelters. Instruction Manual. Sunblocker Shade House 10' Wide x 30' Long SKU #1030SPC. Note: Photo may be of a different but similar model

Fencing and Trellising made easy

INVITATION FOR TENDERS BOSNIA AND HERZEGOVINA. CONSTRUCTION OF MOTORWAY ON CORRIDOR Vc, SECTION POČITELJ - BIJAČA, SUBSECTION POČITELJ - ZVIROVIĆI

East Lancashire Highways and Transport Masterplan East Lancashire Rail Connectivity Study Conditional Output Statement (Appendix 'A' refers)

Professional Installation Guidelines LVT with Roll-out Loop over LocPlate products. Required Tools

FOAM PROPORTIONING EQUIPMENT

ANGLIAN WATER GREEN BOND

Safeguard Barriers. For Motorsport Protection

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Ferrule Design Manual

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

SEASONAL ANCHOR SYSTEM FOR PAIR OF PORTABLE SOCCER GOALS

TABLE SYSTEM.

9 Station Swing Set User Manual

Wood Burning Stove Safety Tips

ADVICE ON Cattle Grids

LYNDHURST NEW URBAN DEVELOPMENT AREA STRUCTURE PLAN. Lyndhurst New Urban Development Area Structure Plan OUTCOMES AND PERFORMANCE STANDARDS

DATA BOOK IV : COST ESTIMATE

Installation Instructions. Woolly Mammoth Stoves Albert Road, Braintree, Essex, CM7 3JQ

300 ft. 5/8 Hose wagon

USE OF RADAR IN THE APPROACH CONTROL SERVICE

ASSEMBLY & CARE INSTRUCTIONS

Wooden Koi/Octagonal Pond Instruction Manual

2 Tripod System User Guide

Flexible Punching Machine

cemetery product division For more information: visit us online toll free

Stainless Steel Catheter Storage Cabinets

Hydraclaw Jacks. *dimensions are in mm. Powerful: 5 tonne capacity on head or toe. High Lift: 178mm. Fast Operation: 5.5mm lift per stroke

OWNER S MANUAL. Item #14103

Rooftop Tent Owners Manual

Green Washrooms. Certifi ed Environmentally Preferred Products. Licence number UK / 4 / 002

ALEKO Victoria Series Retractable Awning Instructions for Installation and Operation

Auxiliary 63.5l Fuel Tank Ford/Mazda Pick-up Truck 2012-Current READ ME! IMPORTANT WARNING!

Alternative Designs Report Joshua s Jumper

OPERATOR INSTRUCTION MANUAL INCLUDING REPAIR PARTS FOR MODULAR GENERAL PURPOSE TENT SYSTEM (MGPTS) TYPE I

ASSEMBLY & CARE INSTRUCTIONS. 7 x4 TRAILER TENT SERIES 4 9. OPTIONAL SUNROOM Wall and floor kit. OPTIONAL SPARE ROOM Roof, wall and floor kit

Abandoned Mine Sites Policy

Spray Adhesives Equipment. Dispensing Equipment for Bulk Sprayable Adhesives

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

COATING AND STRUCTURAL CONCRETE COATING (ANTI-GRAFFITI) 1'-3" FINISHED GRADE 1'-3" 3" VENEER ALLOWANCE LEDGER W/ MECHANICAL ANCHOR BOLT

MANUFACTURER OF QUALITY BLEACHERS, BENCHES, & PICNIC TABLES FOR OVER 25 YEARS

Antenna Tower Positioning System

EXCELSIOR FIRE DISTRICT

Transcription:

Off-Site Solutions CPM Headwalls Concrete for Life

Welcome to CPM CPM is a market leading manufacturer of concrete products with production facilities across the UK. This combined with a network of specialist distributors, enables us to provide our customers with complete coverage. The CPM business is built on a solid reputation for delivering quality products and providing a first class service with diversification and innovation a key to our strength. We supply a vast range of sustainable precast concrete products to every sector of the construction industry, fully supported by our experienced technical and engineering teams. CPM Headwall Solution CPM has developed an offsite precast concrete solution headwall system designed to connect pipe work discharging into open water courses. The spillway headwall offers a cost effective alternative to in-situ structures for connecting discharge from pipework into open watercourses, such as culverts, collection ponds, balancing ponds, rivers and swales. Concrete pipeline systems have a proven life of over 100 years, demonstrating lower whole life costs and providing installed cost savings as well as minimising erosion at the discharge point and immediate structure. CPM headwalls are the ultimate recycling product as they can be removed and refitted elsewhere should the need arise. CPM Headwalls are compliant with the Sewers for Adoption standard The precast concrete headwall is available in three standard sizes: S40 (small), S60 (medium) and S90 (large). These three sizes accommodate a range of connecting pipes from 150mm to 900mm outlets. Advantages of the CPM precast concrete headwalls include Proven design life of 100 years Lower whole life costs cost effective option Low maintenance Quick and efficient installation Offsite solution made under factory conditions No on-site shuttering or formwork required Increased health and safety on-site with off-site manufacturing Reduction in carbon footprint A full range of accessories available from stock The headwall and toe are manufactured as separate monolithic precast units. CPM operates a quality management system accredited to ISO 9001 with all constituent products subject to regular quality inspection. Both components are manufactured to exposure class XD3.

Components A spillway Headwall will typically comprise of two standard elements. Headwall headwall units can comprise of the following: A precast concrete unit, size dependant on connecting pipe (three sizes available). Fitted with closed coupled and cranked gratings. Pre fitted with hydro-brakes, penstocks, non-return flap valves. Toe Toe units can comprise of the following: A precast concrete unit, size dependant on ordered headwall and depth to adjacent water course (three heights available for each headwall size). Accessories A full range of accessories are available, including flap valves, penstocks, hydro-brakes, silt traps, safety gratings, hand rails etc. Concrete for Life

CPM Headwall Range Headwall Sizes Small - S40 Medium - S60 Large - S90 Pipe Diameters up to 375 up to 600 up to 900 Hole Sizes Designed Pipe Diameter 150 225 300 375 450 525 600 675 750 825 900 Table Key: = stock item = made to order Minimum Hole Size 198 320 460 540 635 720 825 870 950 1035 1130 Small S40 Medium S60 Large S90 Headwall Images

Offloading and Lifting CPM is able to offer advice and recommendations for offloading products on site and assist in the preparation of a safe delivery plan in accordance with the HSE document Delivering safety: co-operating to prevent workplace vehicle accidents. CPM recommends that ALL lifting operations should comply with the Lifting Operations and Lifting Equipment Regulations (LOLER) 1998, and the Provision and Use of Work Equipment Regulations 1998 (PUWER). The lift system is of a Utility Anchor system incorporating a cast-in loop, adequately rated lifting brothers can attach directly for lifting, where brothers are too large to safely be placed, D Shackles should be used. More information is available at www.cpm-group.com Spillway Headwall Toe S60 Concrete for Life

Receipt and Handling of Headwalls on Site Time and place of off-loading should be agreed before units arrive at site. For safety, all units are delivered in the upright position as installed. During delivery and off-loading, the units should be placed on 300mm skids to ensure no damage to the toe end. Units must be stored individually and not stacked. Off-loading should take place at the nearest hard standing area to the point of installation. Off-loading must be carried out using appropriate lifting equipment. It is recommended that telescopic handlers, or equivalent, with forklift toes are used to off-load on-site, lifting from the back of the unit (or sides of the headwall only), to prevent operatives from climbing onto the trailer. Each headwall section is supplied with 3 lifting anchors cast into the reinforced floor for site handling. The units Centre of Gravity has been calculated so there is no need to shorten the chains, but we advise a test lift prior to installation so that the contractor is happy with the angle to help guide the opening over the pipeline. If needed, shorten the legs accordingly so that the back of the unit is lower than the front. Each Toe unit has 2 cast-in anchors with 2 equal chains used to transport on site and position. Carefully inspect units during off-loading to verify that products are undamaged and comply with the units ordered. Two types of check are required: Visual Inspect the headwall and/or extended toe for any sign of damage, including cracked or chipped concrete, or damage that could affect the performance. Design Check that the item received is the one ordered. Headwalls are a standard CPM product and are labelled with the following information: Headwall Size Pipe Diameter Production date All CPM products are stamped with the production date (this is part of a quality control procedure). Any Headwalls rejected should be labelled and stored separately with the discrepancies for each noted on the delivery docket and reported for further action.

Installation Guide Cut and install the last section of pipe that the headwall will cover. Ensure that the pipe is fully fitted, leaving either the first (or last) section of pipe free from backfill to allow the headwall to locate over it. Excavate to formation level, and dig a trench to suit the toe, place and compact a 300mm bed of 50mm clean drainage stone or similar free drainage aggregate (compacted in 100mm layers). Check that the correct headwall and toe has been brought to the installation point. Cross reference and check pipe connection diameter to that of the headwall. The movement of the toe and headwall on-site must be undertaken in a manner that is safe and will not cause any damage to the units in any way the use of the cast-in lifting anchors connected to equal length 2 legged chains is recommended for lifting the toe ensuring a minimum lifting angle of 60 degrees. Place the toe into the bedded trench and confirm levels and alignment, backfill the voids with 50mm clean drainage stone to approximately 200mm below the crown of the toe and level off the bed. Ensure the ends of the toe are not exposed and place approximately 200mm of lean mix concrete behind the toe filling up to the crown of the unit, ensuring a level surface for the headwall to rest on. Lift the headwall unit with 3 legged chains and manoeuvre it so the opening is over the pipeline and lower the toe register into the positioned toe until resting completely on the prepared bed. Placing a shim to the underside of the pipe to centre in position as required. Using the appropriate grout or an epoxy resin, fill in the void between the reinforced concrete headwall and the pipe. This will ensure a firm fit. Backfill the pipe section between the headwall and embankment. It is recommended that 300mm surround of 50mm or similar free drainage aggregate is used to surround the headwall to ensure good groundwater drainage. Disclaimer This document is produced by the CPM Group as a recommended guideline document to the industry. Its purpose is to aid contractors in the installation of the CPM precast concrete headwalls. It is the responsibility of the contractor to ensure that the precast concrete headwall is in accordance with the design specifications for the site. It is the responsibility of the contractor to install the precast concrete headwall safely in accordance with site conditions. Concrete for Life

Technical Spillway Diagrams Off-Site Solutions Spillway Headwall S40

Technical Spillway Diagrams Spillway Headwall S60 Spillway Headwall S90 Off-Site Solutions Spillway Headwall S60 Concrete for Life

Technical Spillway Diagrams Off-Site Solutions Spillway Headwall S90

Headwall Accessories Headwall Flap Headwall Grill Headwall Silt Trap Headwall Handrail Hydro-Brake Concrete for Life

Complete UK Coverage HEAD OFFICE / ENGLAND / WALES SALES AND SOUTHERN WORKS CPM Group Ltd, Mells Road, Mells, Nr Frome, Somerset, BA11 3PD Tel: 01179 814500 Fax: 01179 814511 NORTHERN WORKS CPM Group Ltd, Pollington, Goole, East Riding of Yorkshire, DN14 0DU Tel: 01405 860591 Fax: 01405 863606 SCOTLAND SALES CPM Group Ltd, 101 Main Street, Newmains, Wishaw, Lanarkshire, ML2 9BG Tel: 01698 386922 Fax: 01698 387167 PERFECT MANHOLE SALES CPM Group Ltd, 1st Floor Alexandra Mill, Queen Street, Leek, Staffordshire, ST13 6LP Tel: 01538 380500 Fax: 01538 380510 TECHNICAL OFFICES CPM Group Ltd, CPM House, Heath Mill Road, Wombourne, Staffordshire, WV5 8AP Tel: 01902 356220 Fax: 01902 356221 sales@cpm-group.com www.cpm-group.com Designed by Pixel Creative www.pixel-creative.co.uk