Productivity. Technician. Maximized. Interpretation Guide

Similar documents
Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

Interpretation Guide. Coliform Count Plate

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

Interpretation Guide

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

Interpretation Guide

REC. Interpretation Guide. Rapid E. coli/coliform Count Plate

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader

3M Food Safety 3M Petrifilm Plates and Reader. Simply. Prompt. Precise. Productive.

Protecting Consumers. Improving lab efficiency. 3M Petrifilm Plates and Reader

NordVal International / NMKL c/o Norwegian Veterinary Institute PB 750 Sentrum, 0106 Oslo, Norway

VALIDATION OF DRY-AGING AS AN EFFECTIVE INTERVENTION STEP AGAINST ESCHERICHIA COLI O157:H7

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

User friendly microbial detection! Sanita-kun R =The ready-to-use cultural medium sheet for the microbial detection =

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Kit Information 3. Sample Preparation 4. Procedure 4. Analysis of Results 5. Quality Control 6. Disposal 6. Technical Support 6. Order Information 6

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

CERTIFICATE OF ACCREDITATION

Addressing challenges associated with the detection of faecal coliform organisms in water matrices. Neil Leat Rand Water Date 30/09/2014

CERTIFICATE OF ACCREDITATION

There are 7 kinds of unique dry medium for hygienic testing and detection of food poisoning bacteria.

Big SHOT III Hybridization Oven

Pr oject Summar y. Survey of the prevalence of Escherichia coli O157:H7 on the surface of subprimal cuts of beef during winter months (Phase I)

Operating Instructions

Innovative New Products

Food Microbiological Examination: Enumeration of Coliforms

Issue Date: March 1, M Petrifilm Plates Certifications, Recognitions and Validations

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

Convenient Media Solutions For food and water testing

A Pre-Paid Return Label is included (optional) *Call for pick up no later than the above return date to avoid additional rental fees

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Operating Instructions

CERTIFICATE OF ACCREDITATION

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

Chromocult Coliform Agar acc. ISO

Made of polypropylene

Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria

Operating Manual. Revision D

COLILERT - WHAT'S AL THE FUSS ABOUT? Elizabeth Hanko. Elizabeth Hanko, Senior Consultant. AWT, Victoria

Sampling for Microbial Analysis

NNIN Nanotechnology Education

Jonathan Howarth Ph.D and Tina Rodrigues BS Enviro Tech Chemical Services Modesto, CA 95258

2522 and 2523 Fiber Optic Splice Organizer Tray

LBH18BPK. Instruction Sheet

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

Project Summary. Principal Investigators: Chance Brooks, Mindy Brashears, Mark Miller, Alejandro Echeverry, and Cassandra Chancey

INSTALL INSTRUCTIONS for VEHICLES

Spill Control. Choice Quality Affordability

PD Series Ram-Air Reserve Parachute Owner s Manual Addendum. PRO Packing Instructions

ANODIZED ALUMINUM STAINLESS CONSTRUCTION

COLIFORM BROTH. Fecal Coliform Broth. M-FC BROTH without ROSOLIC ACID (Blue background)

container specs crack resistant

Critical considerations for the design of a safe, performing and compliant medical package

Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

Safety & Warnings. A Material Safety Data Sheet for this product is available upon request by contacting

Proficiency Testing. Food Microbiology. January Laurence Nachin, Christina Normark and Irina Boriak

An ISO 13485:2016 & US-FDA Audited Co.

Introduction TEFLON PFA Filtration

Professional Mandoline Manual. Model: 90797

Herolily USA Inc., headquartered in Los Angeles, California was the first company to introduce cuttingedge, game-changing cold packs to the USA

IMPORTANT NOTICE. Professional Mandoline Manual

Professional Mandoline Manual. Model: 90757

Food Stamp Hygiene control on food and food Environment

Effectiveness of Interventions to Reduce or. Colin Gill Lacombe Research Centre

- Make sure the anaerobic tent will be available on the days you plan to use it. - Make sure the autoclave/incubator will be available.

Making Solar Cells 1 from Household Materials (mostly :)

Proficiency Testing FINAL REPORT Check sample program 16CSP02 February 2016

collapsible background INSTRUCTIONS

IDEXX Summary. D P Sartory and C Allaert Vandevenne

Bacterial Interference with Coliform Colony Sheen Production on

INFUSION TUBES STANDARD INFUSETTE TUBES

PlatyPus cleanstream Gravity FiltEr system ENG instruction manual

Written By: Arthur Shi

Tea Chest: $3.99 EA When you buy 10 or more. or $4.50ea

Catalog Bag at a Time, Inc. PO Box 744, Venice CA

high performance pipettors Excellence and precision for all your liquid handling procedures.

WORLD S NO. 1 IN TOILET ADDITIVES

BACTERIOLOGICAL MONITORING 109 TRAINING COURSE $ HOUR RUSH ORDER PROCESSING FEE ADDITIONAL $50.00

Titan3 Syringe Filters. Sample Preparation 1-036

Thermostatic Griddle Field Service Kit Instructions

Written By: Sam Lionheart

r., C D C5,) -I2ET dun 241,%3 Sco C)6 C-.) TISIA TECHNICAL DOCUMENTARY REPORT AAL-TDR-6Z-55 AAL- TDR-62-55

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SECTIONING PROCEDURE FOR LASER CAPTURE MICRODISSECTION

Colilert * -18 A faster, easier way to test for total coliforms and E. coli

Bacterial Quality of Crystalline Rock and Glacial Aquifers in New England

Performing Hand Hygiene Using an Alcohol-Based Handrub

Project Summary. Principal Investigators: Lawrence D. Goodridge 1 ; Phil Crandall 2, and Steven Ricke 2. Study Completed 2010

Food Stamp Hygiene control on food and food environment

MEDICAL PRODUCTS FOLDER

Professional Installation Guidelines LVT with Roll-out Loop over LocPlate products. Required Tools

SPARE PARTS AND CONSUMABLES CATALOG SECOND QUARTER 2015 BLUEWATER SPIRIT WATER PURIFIER

Laboratories & Consulting Group

Transcription:

3M Food Safety 3M Petrifilm Aqua Heterotrophic Count Plate 3M Petrifilm Aqua Coliform Count Plate Technician Productivity Maximized Interpretation Guide Introducing 3M Petrifilm Aqua Heterotrophic Count Plate and Coliform Count Plate for Water Testing, offering four plates to cover your unique testing needs Heterotrophic Count, Coliform Count, Enterobacteriaceae Count and Yeast & Mold Count. 3M Petrifilm Aqua Plates are ideal for testing bottled water.

Interpretation Guide: 3M Petrifilm Aqua Plates for Water Testing The 3M Petrifilm Aqua Plate system brings the convenience of 3M Petrifilm Plate technology to water testing 1. The 3M Petrifilm Aqua Plate s compact, easy-to-use format brings space savings and reduced waste to the laboratory. An independent, third party study 2 indicates 3M Petrifilm Aqua Plates do not perform statistically different from either SMEWW 3 or ISO 4 bottled water testing reference methods. This guide familiarizes you with results on the 3M Petrifilm Aqua Heterotrophic Count Plate and 3M Petrifilm Aqua Coliform Count Plate. For more information, contact the official 3M Food Safety representative nearest you. 3M Petrifilm Aqua Heterotrophic Count Plate (AQHC) The 3M Petrifilm Aqua Heterotrophic Count (AQHC) Plate is a sample-ready culture medium system which contains Standard Methods nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration in the bottled water industry. Count all red colonies on 3M Petrifilm Aqua AQHC Plates regardless of size or color intensity. See Pages 3 5 3M Petrifilm Aqua Coliform Count Plate (AQCC) The 3M Petrifilm Aqua AQCC Plate is a sample-ready culture medium system which contains Violet Red Bile (VRB) nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration. 3M Petrifilm Aqua AQCC Plates are used for the enumeration of coliforms in the bottled water industry. On 3M Petrifilm AQCC plates, confirmed colonies are red associated with gas, if present other red colonies without gas have to be confirmed following reference confirmation methods. See Pages 6 7 Low number of colonies with gas bubbles 1 3M has not documented the performance of 3M Petrifilm Aqua Plates for water samples other than bottled water. The use and validation of 3M Petrifilm Aqua Plates to test other types of water samples, such as process or rinse water, is at the sole discretion and responsibility of the end user. 2 Q Laboratories, Inc, Cincinnati, OH, USA study comparing 3M Petrifilm Aqua Plate performance vs. reference methods. Study presented at 2011 International Association for Food Protection (IAFP). 3 Standard Methods for the Examination of Waste Water (SMEWW) 9215A6a and 9222E2b 4 SO 6222, ISO 9308-1 2

3M Petrifilm Aqua Heterotrophic Count Plate (AQHC) Negative Plate and Plates with Colonies on Filters Figure 1 AQHC plate with filter Count: 0 Figure 2 AQHC plate with low count on filter Count: 8 cfu Observation: Count all colonies regardless of their size or color intensity. Figure 3 AQHC plate with high count on filter Count: 24 cfu Observation: Note colony morphology is altered by colony-associated gas production. See circle for example. Figure 4 AQHC plate with high count on filter Count: 71 cfu 3

Interpretation Guide: 3M Petrifilm Aqua Plates for Water Testing 3M Petrifilm Aqua Heterotrophic Count Plate (AQHC) Plates with High Counts on Filters Figure 5 AQHC plate with colonies too numerous to count on filter Observation: Colonies vary in size and color intensity. Figure 6 AQHC plate with colonies too numerous to count on filter 4

Negative Plate and Plates with Colonies 1mL Direct Plate (No Filter) Figure 7 AQHC plate Count: 0 Figure 8 AQHC plate with high count Count: 64 cfu Observation: Count all colonies regardless of their size or color intensity. Figure 9 AQHC plate with colonies too numerous to count Count: estimate 10 3 cfu Observation: Determine the average number of colonies in one square (1cm 2 ) and multiply it by 20 to estimate the total count per plate. 5

Interpretation Guide: 3M Petrifilm Aqua Plates for Water Testing 3M Petrifilm Aqua Coliform Count Plate (AQCC) Negative Plate and Plates with Colonies on Filter Figure 1 AQCC plate with filter Count: 0 Observation: Gas bubbles surrounding filter do not indicate microbial growth. See circle for example. Figure 2 AQCC plate Count: 0 cfu Observation: Red colonies without closely associated gas bubbles may be coliforms and should be picked and tested with appropriate confirmation methods. Figure 3 AQCC plate with low count on filter Count: 3 cfu Observation: Coliforms produce acid (faint pink halo associated with colonies) and are associated with gas bubbles. 6

Plates with High Counts on Filter A C B Figure 4 AQCC plate on filter Count: 10 cfu Figure 5 AQCC plate with high count on filter Count: 30 cfu Observation: Gas bubbles influence colony morphology: Coliform distorted by gas bubble (circle A ); faint colony underneath gas bubble (circle B ). Note large artifact gas bubble in the center of the plate (circle C ). 7

Reminders for Use 3M Petrifilm Aqua Heterotrophic Count Plate (AQHC) Storage for Plates 8 C A Store unopened packages at 8 C ( 46 F). Use before expiration date on package. In areas of high humidity where condensate may be an issue, it is best to allow packages to reach room temperature before opening. Inoculation or Hydration Procedure B To seal opened package, fold end over and tape shut. Do not refrigerate opened packages. Use 3M Petrifilm Aqua AQHC Plates within one month after opening. C Place 3M Petrifilm Aqua Plate on a level surface. With the pipette perpendicular to the 3M Petrifilm Aqua AQHC Plate, place 1mL of sample OR hydration diluent onto the center of the bottom film. D Carefully roll top film down so that it contacts the sample or hydration diluent and then drop the top film. E With ridge side down, place spreader on top film over inoculum or hydration diluent. F Gently apply pressure on spreader to distribute inoculum or hydration diluent over circular area before gel is formed. Do not twist or slide spreader. Lift spreader. When direct plating a sample, wait a minimum of one minute for gel to solidify. Proceed to step J. When inoculating with hydration diluent, allow the hydrated plates to remain closed for a minimum of one hour before use. Proceed to step G. Any additional hydrated 3M Petrifilm Aqua AQHC Plates may be stored in a sealed pouch or plastic bag. Protect plates from light and refrigerate at 2 8 C (36 46 F) for up to 14 days. IMPORTANT If you are direct plating, skip to step J. If you are using a 3M Petrifilm Aqua AQHC Plate with a filter, proceed to step G. 8

Inoculation Steps for Plates with Filters G Following standard procedures for water analysis, membrane filter water sample using a 47mm, 0.45 micron pore size Mixed Cellulose Ester (MCE) filter. H Lift the top film. Place filter in the center of the hydration area, grid side up. Roll top film down to minimize air bubbles or gaps between the filter and the 3M Petrifilm Aqua AQHC Plate. I Lightly apply pressure to ensure uniform contact of the filter with the gel and to eliminate any air bubbles. Incubation J Incubate 3M Petrifilm Aqua AQHC Plates in a horizontal position, clear side up, in stacks on no more than 20 plates at 36 +/-2 C, 35 +/-1 C - or 22 c +/- 2 c for 68+/-4 hours, or 36 C +/- 2 c or 35 C +/- 1 c for 44 +/-4 hours depending on the temperature recommended by local regulation. A filtration procedure can also be used depending on the regulation. Interpretation K 3M Petrifilm Aqua AQHC Plates can be counted on a standard colony counter or other illuminated magnifier. Refer to the Interpretation Guide section when reading results. L Colonies may be isolated for further identification. Lift top film and pick the colony from the gel. 9

Reminders for Use 3M Petrifilm Aqua Coliform Count Plate (AQCC) Storage for Plates 8 C A Store unopened packages at 8 C ( 46 F). Use before expiration date on package. In areas of high humidity where condensate may be an issue, it is best to allow packages to reach room temperature before opening. B To seal opened package, fold end over and tape shut. Do not refrigerate opened packages. Use 3M Petrifilm Aqua AQCC Plates within one month after opening. Hydration Procedure C Place 3M Petrifilm Aqua AQCC Plate on a level surface. With the pipette perpendicular to the 3M Petrifilm Aqua Plate, place hydration diluent onto the center of the bottom film. D Carefully roll top film down to avoid entrapping air bubbles. Do not let top film drop. E With flat side down, place spreader on top film over hydration diluent. F Gently apply pressure on spreader to distribute inoculum or hydration diluent over circular area before gel is formed. Do not twist or slide spreader. Lift spreader. Allow the hydrated plates to remain closed for a minimum of one hour before use. Proceed to step G. Any additional hydrated 3M Petrifilm Aqua AQCC Plates may be stored in a sealed pouch or plastic bag. Protect plates from light and refrigerate at 2 8 C (36 46 F) for up to 7 days. 10

G H Following standard procedures for water analysis, membrane filter water sample using a 47mm, 0.45 micron pore size Mixed Cellulose Ester (MCE) filter. Lift top film. I Place filter in the center of the well. Roll top film down to minimize air bubbles or gaps between the filter and the 3M Petrifilm Aqua AQCC Plate. Incubation J Lightly apply pressure to ensure uniform contact of the filter with the gel and to eliminate any air bubbles. K Incubate 3M Petrifilm Aqua AQCC Plates in a horizontal position, clear side up, in stacks on no more than 20 plates at 35 ± 1 C for 24 ± 2 hours or 36 ± 2 C for 24 ± 2 hours depending on temperature mentioned in local regulation. Interpretation L 3M Petrifilm Aqua AQCC Plates can be counted on a standard colony counter or other illuminated magnifier. Refer to the Interpretation Guide section when reading results. M Colonies may be isolated for further identification. Lift top film and pick the colony from the gel. 11

3M Food Safety offers a full line of products to accomplish a variety of your microbial testing needs. For more product information, visit us at www.3m.com/foodsafety. Food Safety 3M Australia Pty Limited 1 Rivett Road, North Ryde NSW 2113 1300 363 878 www.3m.com.au/foodsafety 3M New Zealand 94 Apollo Drive, Rosedale Auckland 0632 0800 808 182 www.3m.co.nz/foodsafety 3M and Petrifi lm are trademarks of the 3M company.