a Nexans company Catalogue 2009

Similar documents
Molded High-Voltage Bushing Wells

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

Spare parts list ( ) Spare parts list BR 40/10 C

SERVICE SHEET 34" WALK-BEHIND POWER TROWEL MODEL FT34 (THIS SERVICE SHEET APPLIES TO THE TROWELS WITH SERIAL NUMBER AND AFTER) WARNING

S36 230V MOTOR COVER

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

APV PUMPS. Puma Pump Series III FREEPHONE: Pump assembly (Series III) Shrouded Type. Unshrouded Type

Smallest Connector with Removable Contacts

Spare parts list ( ) Spare parts list BR 30/4 C Bp

TECHNICAL INFORMATION

V 50.1 BR2. Vario Clamp Spare Parts List (until week 13/2013) Spare parts

FIBER OPTIC CLOSURES

COLGED. Isytech

Parts Catalog. Slicing Machine G10. Model:

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

NK Multi-stage submersible pumps

Amphenol RF Interconnects TNC 31 Series Threaded Lock RF Connector System Materials

Special Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change

2M804 Push-Pull Crimp Receptacles Ordering Guide for 2M , 002, 003, 004

Product Range. Switches Spur Units Sockets Communication Accessories Other Modules Front Plates & Frames 23-28

Ultraflow Compact Housing and Winter Kit

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

AXELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories. Technical manual

Spare parts list PVX open loop CW

Blue Series Hot Melt Hose with RediFlext II Hanger System

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W


Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

Emergency Stop Devices

AXICOM COMPOSITE HOLLOW CORE INSULATORS STANDARD TYPES

General Purpose High Power PCB Relays

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

PARTS LIST eforce Burnisher

PARTS LIST CHARGER 2022 ABLT

Parts Catalog EVM/EVM2/EVM3 REPAIR PARTS CATALOG NO. M50206(V)

Bruna Epdm Neopr Sizes: ½, ¾, 1, 1 ¼, 1 ½, 2, 2 ½, 3, 4, 5, 6 Full Teflon Viton CAM ARMS - PINS RINGS FOR CAMLOCKS

TECHNICAL DATA SHEET

SIZE RANGE: 1 TO 10. PRESSURE RANGE: FULL VACUUM TO 275 psi

NORMACLAMP Hose Clamps

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Parts Catalog. S-Series Slicer Manual S13. Model:

Data Sheet for Precision Potentiometer

Eclipse Hermetic Gas Boosters Series HB

ELECTRA MAGIC RV and Marine Recirculating Toilets

Flange. Connection Trunnion Ball Valves.

Airfield Lighting. 12" Bidirectional High/Medium-Intensity Inset Light (INL-RN) Product Description

PARTS BOOK CATALOG SIDE HD FLAIL HEADS TRACTOR MID-MOUNT

POSEIDON 4. Part List US-English

SUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).

SUB-STRUCTURES. SUB - STRUCTURES III Page 1 of 28. Overhead Electric Distribution Standards INTRODUCTION

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

Model Number Structure

Parts Catalog T7/T71/T73 M40000/M40001/M40003

Glass Door Fittings Glass Door Accessories

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

Section 11 Workstation Components

WRANGLER 1710AB, 2010AB

2M Hermetic General Information. Why 2M Hermetic? GHEC 81. Amphenol s 2M Micro38999 Connector Series The New Aerospace Standard. Page Guide.

Mahavir Enterprises.

Parts Catalog T7/T71/T73 M40000/M40001/M40003

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

STIH) Technical Information Cut-off machine STIHL Cutquik TS 410, 420 Series Guard with defined adjustment range

Parts Catalog Issued: Jul 22, ICCI IH820 Series

Airfield Lighting. 12" Unidirectional High/Medium-Intensity Inset Light (INL-AP) Product Description

Safety Interlock Switches

RTA flexible conduits

PARTS LIST COLT COLT HEPA

CATALOG OF REPLACEMENT PARTS

Hydraclaw Jacks. *dimensions are in mm. Powerful: 5 tonne capacity on head or toe. High Lift: 178mm. Fast Operation: 5.5mm lift per stroke

Data Sheet for Precision Potentiometer

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

MK3000. Operating and Calibration Instructions

TB131. Gas Conversion Kits for NVx & VPC Heaters. Issue 1.0 May Applies to models: NVx & VPC

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can.

Cassette-folding arm-awning markilux 990

INSTALLATION GUIDELINES

User Manual for Separera 40

Manual Actuator. CR / CM Levers. Type Series Booklet

Terminals & Connectors

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

EC BRUSHLESS MOTOR APPLICATIONS

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

WARNING DEVICES ATEX. V.le Rimembranze, Sesto S. G. (MI) ITALY Ph.: a.r. Fax:

CEELOK FAS-T CONNECTORS

IB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Conservatory awning W8 Description

FastLine. Contents. FastLine Description... 14/2 Ordering Details... 14/3 Technical Data... 14/7 14/1 1SBC R1001

Transcription:

a Nexans company Catalogue 2009

EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: pre-moulded EPDM or silicone rubber connectors, terminations and joints for cables and epoxy s for transformers and switch gear, as well as a large range of cold-shrinkable terminations and joints from to 42 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 9001 Certificate Since 1992, Euromold s commitment to quality is demonstrated by its ISO 9001 certification. International All our products meet the International like CENELEC HD 629.1, CENELEC EN 50180, IEC 137, IEEE 386 & 404 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 2000, Euromold s independent ELAB laboratory obtained the BELTEST accreditation no.192-t-iso 17025 conform with the European for laboratories ISO 17025 for electrical testing of medium voltage cable accessories according to the International IEC 61442 and HD 629. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions n.v. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as and technology evolve. 1

EQUIPMENT BUSHINGS Table of contents 180AR-1 - interface A 180AR-2 - interface A 180AR-3 - interface A 180A-P-O - interface A in-air 250SFR-P - interface A 400T1 - interface B 400AR-1 - interface B 400AR-2 - interface B 400SFR-P - interface B 400AR-3 - interface C 400AR-4 - interface C 400AR-5 - interface C 400AR-6 - interface C 400A-B - interface C in-air 400SFR-B - interface C 2

Interface A Dimensions according to European CENELEC EN 50180 and 50181 (in mm). Dia. 44.5 ±0.2 Dia. 32.5 ±0.2 Dia. 31 +0.1-0.3 Dia. for pin 7.9 +0.02-0.05 48 0-0.2 9 min. Dia. 48.5 ±0.2 Interface B Dimensions according to European CENELEC EN 50180 and 50181 (in mm). Dia. 56 ±0.2 Dia. 46 ±0.2 Dia. for pin 14 0-0.04 40 min. 90 ±0.2 11 min. Dia. 70 ±0.2 Interface C Dimensions according to European CENELEC EN 50180 and 50181 (in mm). Dia. 56 ±0.2 Dia. 46 ±0.2 Dia. 22 min. M16 x 2-6H 0 1.5-0.5 29 min. 90 ±0.2 11 min. Dia. 70 ±0.2 3

180AR-1 /180AR-2 /180AR-3 INTERFACE A EQUIPMENT BUSHINGS Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. Specifications and The plug-in type s 180AR- meet the requirements of CENELEC EN 50180 and IEC 137. Up to kv - 250 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The s are moulded epoxy insulated parts in accordance with CENELEC EN 50180. The 180AR-2 has a length B outside this standard. The standard s, (K)180AR-1 /-2 /-3, are equipped with 6 tabs for the bail restraint. The (K)180AR-1-G and (K)180AR-3-G are equipped with 4 tabs and 2 threaded inserts M6 (-G version). Type 180AR-1-G /-3-G Type 180AR-1 /-2 /-3 M6 11 28 8 A B To order the, specify the type. The s are supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. K180AR-1/J. Minimum oil level: - kv: 40 mm - kv: 50 mm Dia. 16 Dia. 75 Dia. 110 M10 19 Equipment type Voltage Ur (kv) Current Ir (A) A Dimensions (mm) B 180AR-1 K180AR-1 180AR-2 K180AR-2 180AR-3 K180AR-3 250 250 250 250 250 250 222 222 284 284 171 171 106 106 168 168 55 55 4

180AR-1/GS 180AR-1-G/GS 180AR-2/GS 180AR-3/GS and 180AR-3-G/GS Bushings To order the clamping kit, according to NFC 52-053, simply specify KBCNF1-200. Contents: - 3 x claw clamp NF - 1 x sealing gasket. FIXINGS FOR EQUIPMENT BUSHINGS 180AR-1/J 180AR-1-G/J 180AR-2/J 180AR-3/J and 180AR-3-G/J Bushings To order the clamping kit, according to DIN 42 538, simply specify: KBCD-200. Contents: - 1 x fixing flange A - 4 x stud clamp E - 1 x sealing gasket. interface fixing studs NF C 52-053 clamp E DIN 42 538 stud clamp sealing gasket tabs for bail restraint A DIN 42 538 fixing flange earth plate earth jumper Fixing dimensions NF C 52-053 French. Fixing dimensions DIN 42 538 German. M8 or M10 M10 27 52 25 55 3 fixing studs Dia. 78 Dia. 6 4 fixing studs Dia. 78 Dia. 3 5

Application For use in insulated with air, typically for dry type transformers, motors, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 180A-P-O INTERFACE A IN-AIR BUSHING Up to kv - 250 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Specifications and The plug-in type s 180A-P-O are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50181 and IEC 137. Dia. 70 59 20 A Dia. 110 To order the, specify the type. The s are supplied with an earth jumper. To include the ring clamp, add: /B, if per British /D, if per German /F, if per French. E.g. 180A-P-O/F. 250 351 Dia. 16 20 B Dia. 80 M10 Equipment type Voltage Ur (kv) Current Ir (A) Creepage distance A-B (mm) 180A-P-O 180A-P-O 250 250 6 6 6

180A-P-O In-air interface fixing studs and nuts M10 earth jumper FIXINGS FOR EQUIPMENT BUSHINGS gasket fixing flange BCA-B or BCA-D fixing flange BCA-F F tabs for bail restraint Dia. 94.5 Dia. 111 4 Dia. 10 Dia. 10 4 Dia. 94.5 Dia. 111 0 F 6 BS 2562 stand.: 0 DIN 42 538 stand.: 3 Dia. 150 Type BCA-B : BS 2562 British Type BCA-D : DIN 42 538 German Fixing dimensions DIN 42 538 German. M10 25 55 0 Dia. 150 Type BCA-F : NFC 52-053 French M8 or M10 27 52 Fixing dimensions NF C 52-053 French. 4 fixing studs 3 fixing studs Dia. 82 Dia. 3 Dia. 82 Dia. 6 7

Application For use in insulated with SF 6 gas. Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 250SFR-P INTERFACE A EQUIPMENT BUSHING Up to kv - 250 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN 50180. The 250SFR-P has a shank outside this standard, adapted to use in SF 6 gas. Specifications and The plug-in type s 250SFR-P meet the requirements of CENELEC EN 50180 and IEC 137. Dia. 70 Dia. 48.5 31 174 95 To order the, simply specify the type. M10 Dia. 20 Dia. 70 Dia. 109 Equipment type Voltage Ur (kv) Current Ir (A) 250SFR-P K250SFR-P 250 250 8

FIXINGS FOR EQUIPMENT BUSHINGS 250SFR-P Bushing for gas insulated switch gear UNMOUNTED 60 60 60 M4 83 M6 Dia. 91.5 Dia. 103.1 MOUNTED interface 6 fixing screws M6 sealing O-ring gasket earth M4 9

400T1 /400AR-1 /400AR-2 INTERFACE B EQUIPMENT BUSHINGS Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. Up to kv - 400 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The plug-in type s are moulded epoxy insulated parts and meet the requirements of IEC 137. The (K)(M)400T1 also meets CENELEC EN 50180. C 10 133 To order the, specify the type. The s are supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. K400AR-1/J. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia. H B A E Dia. 70 Dia. F Dia. G D In mm Equipment type Voltage Ur (kv) Current Ir (A) Dimensions (mm) A B C D E Dia. F Dia. G Dia. H 400T1 K400T1 M400T1 400AR-1 K400AR-1 M400AR-1 400AR-2 K400AR-2 M400AR-2 400 400 400 400 400 400 400 400 400 310 310 310 380 380 380 329 329 329 144 144 144 213 213 213 138 138 138 M M M M M M M16 M16 M16 22 22 22 22 22 22 40 40 40 88 88 88 74 74 74 100 100 100 8 8 8 8 8 8 150 150 150 16 16 16 16 16 16 10

400AR-2/GS Bushing To order the clamping kit, according to NFC 52-053, simply specify KBCNF-400 (for type 400AR-2). Contents: - 4 x claw clamp NF - 1 x sealing gasket. FIXINGS FOR EQUIPMENT BUSHINGS 400AR-1/J and 400T1/J Bushings To order the clamping kit, simply specify: KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. interface fixing studs NF C 52-053 claw clamp fixing flange B DIN 42 538 E DIN 42 538 stud clamp sealing gasket tabs for the bail restraint earth jumper earth plate Fixing dimensions NF C 52-053 French. Fixing dimensions DIN 42 538 German. M10 or M M10 50 to 70 55 25 4 fixing studs Dia. 105 Dia. 171 6 fixing studs Dia. 90 Dia. 140 In mm 11

Application For use in insulated with SF 6 gas. Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400SFR-P INTERFACE B EQUIPMENT BUSHING Up to kv - 400 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN 50180. The 400SFR-P has a shank outside this standard, adapted for use in SF 6 gas. Dia. 70 218 Specifications and The plug-in type 400SFR-P meets the requirements of CENELEC EN 50180 and IEC 137. 33 To order the, simply specify the type. 95 Dia. 25 Dia. 70 Dia. 109 M Equipment type Voltage Ur (kv) Current Ir (A) 400SFR-P K400SFR-P 400 400

FIXINGS FOR EQUIPMENT BUSHINGS 400SFR-P Bushing for gas insulated switch gear UNMOUNTED 60 60 60 M4 83 M6 Dia. 91.5 Dia. 103.1 MOUNTED interface 6 fixing screws M6 sealing O-ring gasket earth M4 13

Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-3 INTERFACE C EQUIPMENT BUSHING Up to kv - 6 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The bolted type s 400AR-3 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 137. 133 To order the, specify the type. The s can be supplied with an earth jumper (/J). E.g. M400AR-3/J. For use in potentially explosive atmospheres (for kv max), order: 400AR-3/ATEX. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia. 25 10 144 3 40 M16 Dia. 70 Dia. 88 Dia. 8 Equipment type Voltage Ur (kv) Current Ir (A) 400AR-3 K400AR-3 M400AR-3 6 6 6 14

400AR-3/J Bushing FIXINGS FOR EQUIPMENT BUSHINGS To order the clamping kit, according to DIN 42 538, simply specify KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. Fixing dimensions DIN 42 538 German. M10 25 55 interface fixing studs B DIN 42 538 fixing flange E DIN 42 538 stud clamp 6 fixing studs Dia. 90 Dia. 140 sealing gasket earth jumper 15

Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-4 INTERFACE C EQUIPMENT BUSHING Up to kv - 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The bolted type s 400AR-4 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 137. 139 To order the, specify the type. The s can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. M400AR-4/GS. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia. 32 10 138 329 40 M16 Dia. 70 Dia. 100 Dia. 150 Equipment type Voltage Ur (kv) Current Ir (A) 400AR-4 K400AR-4 M400AR-4 50 50 50 16

400AR-4/GS Bushing FIXINGS FOR EQUIPMENT BUSHINGS To order the clamping kit, according to NFC 52-053, simply specify KBCNF-400. Contents: - 4 x claw clamp NF - 1 x sealing gasket. Fixing dimensions NF C 52-053 French. M10 or M 50 to 70 interface fixing studs 4 fixing studs Dia. 105 Dia. 171 NF C 52-053 claw clamp sealing gasket earth plate 17

Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-5 INTERFACE C EQUIPMENT BUSHING Up to kv - 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The bolted type s 400AR-5 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 137. 139 To order the, specify the type. The s can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. M400AR-5/GS. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia. 32 72 32 5 M16 Dia. 76 Dia. 150 Equipment type Voltage Ur (kv) Current Ir (A) 400AR-5 K400AR-5 M400AR-5 50 50 50 18

400AR-5/GS Bushing FIXINGS FOR EQUIPMENT BUSHINGS To order the clamping kit, according to NFC 52-053, simply specify KBCNF-400. Contents: - 4 x claw clamp NF - 1 x sealing gasket. Fixing dimensions NF C 52-053 French. M10 or M interface 50 to 70 fixing studs 4 fixing studs Dia. 81 Dia. 171 NF C 52-053 claw clamp sealing gasket earth plate 19

Application For use in insulated with oil fluid, typically for transformers, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-6 INTERFACE C EQUIPMENT BUSHING Up to kv - 6 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/ () kv Specifications and The bolted type s 400AR-6 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 137. To order the, specify the type. The s can be supplied with an earth jumper (/J). This earth must be specified when ordering. E.g. M400AR-6/J. 132 10 398 213 Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia. 25 40 Dia. 70 Dia. 88 Dia. 8 M16 Equipment type Voltage Ur (kv) Current Ir (A) 400AR-6 K400AR-6 M400AR-6 6 6 6 20

400AR-6/J Bushing FIXINGS FOR EQUIPMENT BUSHINGS To order the clamping kit, according to DIN 42 538, simply specify KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. Fixing dimensions DIN 42 538 German. interface fixing studs M10 25 55 fixing flange B DIN 42 538 E DIN 42 538 stud clamp 6 fixing studs Dia. 80 Dia. 140 sealing gasket earth jumper 21

Application For use in insulated with air, typically for dry type transformers, motors, switch gear, capacitors... Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400A-B INTERFACE C IN-AIR BUSHING Up to kv - 6 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Specifications and The bolted type s 400A-B are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 137. 20 To order the, specify the type. The s are supplied with an earth jumper. To include the ring clamp, add: /B, if per British /D, if per German /F, if per French. E.g. 400A-B/D. For use in potentially explosive atmospheres (for kv max), order: -/ATEX. A Dia. 80 Dia. 110 Dia. 25 250 434 40 B Dia. 80 M16 Equipment type Voltage Ur (kv) Current Ir (A) Creepage distance A-B (mm) 400A-B 400A-B 6 6 500 500 22

400A-B In-air FIXINGS FOR EQUIPMENT BUSHINGS interface fixing studs and nuts M10 earth jumper gasket fixing flange BCA-B or BCA-D fixing flange BCA-F F Dia. 94.5 Dia. 111 4 Dia. 10 Dia. 10 Dia. 94.5 4 Dia. 111 0 F 6 BS 2562 stand.: 0 DIN 42 538 stand.: 3 Dia. 150 Type BCA-B : BS 2562 British Type BCA-D : DIN 42 538 German Fixing dimensions DIN 42 538 German. 0 Dia. 150 Type BCA-F : NFC 52-053 French Fixing dimensions NF C 52-053 French. M10 M8 or M10 55 25 52 27 4 fixing studs 3 fixing studs Dia. 82 Dia. 3 Dia. 82 Dia. 6 In mm 23

Application For use in insulated with SF 6 gas. Technical characteristics Each is tested for AC withstand and partial discharge prior to leaving the factory. 400SFR-B INTERFACE C EQUIPMENT BUSHING Up to kv 6 A & 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN 50180. The 400SFR-B has a shank outside this standard, adapted to use in SF 6 gas. Dia. 70 219.5 Specifications and The bolted type 400SFR-B meets the requirements of CENELEC EN 50180 and IEC 137. 33 95 To order the, simply specify the type. M Dia. D Dia. 70 Dia. 109 Equipment type Voltage Ur (kv) Current Ir (A) Dia. D (mm) 400SFR-B K400SFR-B M400SFR-B 400SFR-B 50 A K400SFR-B 50 A M400SFR-B 50 A 6 6 6 50 50 50 25 25 25 32 32 32

FIXINGS FOR EQUIPMENT BUSHINGS 400SFR-B Bushing for gas insulated switch gear UNMOUNTED 60 60 60 M4 83 M6 Dia. 91.5 Dia. 103.1 MOUNTED interface 6 fixing screws M6 sealing O-ring gasket earth M4 25

Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan, B-9320 Erembodegem Tel.: +32 (0)53 85 02 11 Fax: +32 (0)53 83 10 13 www.nexans.com info.euromold@nexans.com Catalogue also available on CD-ROM