Operating Instructions VETTER Pneumatic Decon Tents

Similar documents
Operating Instructions VETTER Medical Tents

Pneumatic tents and showers. Immediately ready to use and extensively equipped.

Pneumatic tents and showers. Immediately ready to use and extensively equipped.

Single Decontamination Shower. Product Manual

Assembly Instructions

Emergency Pneumatics. Medical tents

Emergency Pneumatics. Medical tents. Product catalogue

Emergency Pneumatics. Medical tents. Product catalogue

FISH CAT SCOUT OWNER S MANUAL

ERECTION INSTRUCTIONS AEROTECH NEVADA 4

AUTO REWIND HOSE REEL USER MANUAL

LODGE 460 CABIN. Part No ASSEMBLY & CARE INSTRUCTIONS

300 ft. 5/8 Hose wagon

S E L E C T I O N. Abdominal Crunch. User manual

STEALTH PRO OWNER S MANUAL

TRAVEL-SMART AWNING SERIES »LYRA 4 « Family Tent. Model No. HW Document-No.: HW Issue: August Top Quality Camping

» AQUILA 320(HIGH TOP) «

» GEMINI 390 CARAVAN«

Inflatable Tent. Medical, Decontamination, Activity

TRAVEL-SMART AWNING SERIES » LYNX 200 LOW TOP « Model No Issue:October Document-No.: LYNX 200 LOW TOP. Top Quality Camping

Brean 4 AIR Instructions & care manual

HUMANITY TENT ASSEMBLY INSTRUCTIONS

300 Model 870 Four Wheel Hose Cart Owner s Manual

Daymer 8 AIR Instructions & care manual

DECONTAMINATION TENTS, SHOWERS, BASINS

IMPORTANT: IN THE EVENT OF A PUNCTURE

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

OWNER S MANUAL. ezup.com. 13 x 13 (4.0m x 4.0m) 10 x 10 (3.0m x 3.0m) 16 x 16 (5.0m x 5.0m)

Air Mattress. Model No.: EAM-DQ1 & EAM DT1. Questions or Concerns? (855)

EVENT TENT HUMANITY TENT ASSEMBLY INSTRUCTIONS

OWNER'S MANUAL FREEDOM AWNINGS

PEUTEREY 40 PEUTEREY 30

ALPTREK 50+5 ALPTREK 45+5

APEX CLIMB 2 OVERVIEW APEX CLIMB 25

Travel Pod Midi AIR Instructions & care manual

OVERVIEW PEUTEREY PEUTEREY 40 / PEUTEREY 30

OVERVIEW GUIDE GUIDE 45 / GUIDE 35

ASSEMBLY & CARE INSTRUCTIONS

EVENT TENT ASSEMBLY INSTRUCTIONS

accidents which arise due to non-observance of these instructions and the safety information herein. CAUTION:

STAR LOUNGE ASSEMBLY INSTRUCTIONS

Ace Air. Instructions & care manual

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

ALP TRAINER 25 2 OVERVIEW ALP TRAINER 25

SOUDATHERM SFI 600P. Revision date: 19/06/2015 Page 1 of 6

JARVIS. Model 70 Airsnip Air Powered Scissors

ERECTION INSTRUCTIONS DRIVEAWAY XC

Oxygen Speed. Annexe Instructions and Care Manual IMPORTANT: PLEASE CHECK YOUR EQUIPMENT

PIONEER LITE PATIO AWNING OWNER'S MANUAL

WARNING USING AND CARING. for use in extreme or varied soil conditions. For optional sand pegs Oztent recomends use of a Bluescrew Oztent Edition.

Brean Instructions & care manual

RANDONEE 36 RANDONEE 30

INSTALLATION INSTRUCTIONS

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

ASSEMBLY & CARE INSTRUCTIONS. 7 x4 TRAILER TENT SERIES 4 9. OPTIONAL SUNROOM Wall and floor kit. OPTIONAL SPARE ROOM Roof, wall and floor kit

INSTRUCTIONS MANUAL CAST IRON STOVE

Retractable Hose Reel

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

Installation and User s Manual 12 x 10 MOTORIZED AWNING

OWNER'S MANUAL CAMPOUT TABLE OF CONTENTS

IMPORTANT: PLEASE CHECK YOUR EQUIPMENT

Travel Pod Xpress Instructions & care manual

10 Economy Popup Tent

Manufactured in our state of the art factory in China

OVERVIEW ALPTREK ALPTREK 40+5 / ALPTREK 35+5

Garden Party 13ft X 13ft 12ft 9in Wide x 12ft 9in Deep x 6ft3in Side Height / 10ft4in Center Height

WE ARE MANUFACTURER!

OVERVIEW LITE TRAIN LITE TRAIN 14 BP

User s Manual Trampoline 8

Operation Manual SUPER BEAST Multi-tool SC-11M-10

Assembly Instructions & User s Manual Grand Ponderosa 10P Cabin Tent

OWNER'S MANUAL FREEDOM WM PATIO AWNING

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

DOWN MANUAL. Aeros Ltd. St. Post-Volinskaya, 5 Kiev, UKRAINE

OVERVIEW ULTRA TRAIN ULTRA TRAIN 18

3x3 Pop Up Gazebo with Side Panels

Model 698/ and Model in 1 Hose Reel Owner s Manual

INSTALLATION INSTRUCTIONS

10' x 20' MAX AP CANOPY Assembly Instructions

10 X 20 X 8 Dome Canopy

electric knife sharpener

5 Scoop stretcher/carrying chair

TWO BURNER STAINLESS STEEL PROPANE STOVE

PIONEER LITE PATIO AWNING

Hose Reel Series L701/G701

FT054 BearMountain OWNER'S MANUAL

Dual Identity. Manufactured in our state of the art factory in China

Hercules 18ft X 20ft 17ft9in Wide x 20ft Deep x 6ft8in Side Height / 11ft6in Center Height

Operation, Cleaning & Maintenance. For Aluminium Secondary

INSTRUCTION SHEET TWISTLOCK VEHICLE STABILIZER (TVS) SYSTEM PN S: , ,

INSTALLATION AND USE OF THE AIR ASSISTED SYSTEM FOR JETSLIDE - AIRASSIST from CANDOCK

Northwest RV Supply Manual Compliments of Printed From OWNER'S MANUAL FREEDOM AWNINGS OTD (OVER THE DOOR) SLIDER AWNING

OVERVIEW CAMMINO CAMMINO CAMMINO CAMMINO 50+10

Manual Awning. Assembly Instructions. Product No Toll-free:

Maintenance Instructions and Directions for Use Wind Support

OVERVIEW KOALA KOALA II

Required Tools: Phillips screw driver to remove original soft top. Torx sockets are required to completely remove the original soft top hardware.

OWNER S MANUAL AND WARRANTY FORM

Transcription:

Emergency Pneumatics. Operating Instructions VETTER Pneumatic Decon Tents Article No. 87018005 Vetter GmbH I 09/17 I Changes and errors excepted.

Vetter Pneumatic Decon Tents Contents 1. Important preliminary remarks...2 2. Description of the product...2 2.1 Scope of delivery...2 2.2 Optional accessories...3 2.3 Correct handling and usage...3 2.4 Safety instructions...3 3. Preparing the product for use...3 3.1 Preparations for operation...3 4. Operating Instructions...4 4.1 Operation with blower (see operating instructions blower)...4 4.2 Operation with compressed air...4 4.3 Use as decontamination tent...5 4.4 Instructions of the showers...6 4.5 Deflation...7 4.6 Folding Plan...8 5. Practical Tips...9 6. Storage...9 7. Repeated Inspections... 10 8. Repair Instructions... 10 9. Technical data... 11 Page 1/12

1. Important preliminary remarks These instructions must be read carefully and complied with at all times to ensure this product is used properly and as intended, to ensure this product provides the greatest possible benefit, and that the entitlements within the scope of the Vetter warranty are preserved. Each use/operation of the pneumatic universal tent requires detailed knowledge and compliance of these instructions. The operating instructions given here are to be regarded as part of the product and are to be kept for the complete life duration of the product. In case the product should be passed on to a successive user then the operating instructions must also be included 2. Description of the product 2.1 Scope of delivery Article No. Description PZ 17 Decon 2 L (1520047000) PZ 40 3 L (1520035500) 1520034500 Tent frame PZ 40 3 L incl. tension rope 1 1520046600 Tent frame PZ 17 Decon 2 L 1 1520034600 Tent floor PZ 40 3 L 1 1520046400 Tent floor PZ 17 Decon 2 L 1 1520034800 Tent cover PZ 40 3 L 1 1520046800 Tent cover PZ 17 Decon 2 L 1 1520034900 Entry covers type PZ 40 3 L with 3 doors 2 1520046900 Entry covers type PZ 17 Decon 2 L with 2 doors 2 1520035000 Separation wall, longitudinal PZ 40 3 L 2 1520046500 Separation wall for PZ 17 Decon 2 L 1 1520034700 Collection tub for PZ 40 3 L 1 1520046300 Collection tub for PZ 17 Decon 2 L 1 1520035300 Shower hose PZ 40 3 L 1 1520046700 Shower hose PZ 17 Decon 2 L 1 1520035100 Shower cover type PZ 40 3 L left/right 2 1520035200 Shower cover type PZ 40 3 L centre 1 1520031100 Shower cover type PZ 17 Decon 2 L 2 1510014700 Decon spray shower 2 6 1510001700 Decon brush-unit 2 6 1520000500 Packing bag (110 x 85 x 60 cm) 1 1523026200 Packing bag (110 x 95 x 100 cm) 1 1520002400 Square earthing pins 18 1520033500 Iron tent pegs, 30 cm 24 1520028301 Repair material 1 1 1520002500 Bag, red, for tent pegs 1 1523013900 Bag, red, for tent pegs 1 Page 2/12

Vetter Pneumatic Decon Tents 1523006800 Hammer 1 1 2.2 Optional accessories Article No. Description 1523003700 Valise for PZ 17 Decon 2 L, 265 x 150 cm (104 x 59 inch), yellow, Incl. auto belt latch 1523013300 Valise for PZ 40 3 L, 330 x 160 cm (130 x 63 inch), yellow, incl. auto belt latch 2.3 Correct handling and usage Always use compressed air with the pneumatic decon tents - never ever use flammable or aggressive gases. Only Vetter original fittings and parts may be used for the pneumatic decon tents. 2.4 Safety instructions Only trained, reliable, and responsible employees are permitted to use and operate this product. Wear the required protective gear and clothing. Please contact the manufacturer or authorized retailer when detecting cracks, fissures, holes, or leakages on the pneumatic supporting frame during the product inspection. Such defects can lead to bursting. Always avoid contact with hot or sharpedged materials. Due to the light design of the pneumatic tents, it is possible that heavy winds may cause stability problems. Always fasten tents with anchoring ropes or use ballast containers. Comply with DIN 7716 if storing the pneumatic universal tents long-term. 3. Preparing the product for use 3.1 Preparations for operation Inspect the pneumatic decon tent before and after each operation to ensure correct and perfect condition. It is imperative that the recommended folding instructions be observed. Page 3/12

4. Operating Instructions Open the packing cover. Lay out the tent at the required location. The ground area must be free of any sharp-edged or pointed objects! The decon tents are designed to be inflated with a blower or with compressed air. 4.1 Operation with blower (see operating instructions blower) The inflation connection for blowers is opened when air flows through. Connect the inflation hose of the blower to the inflation connection of the tent. Unscrew the cap from the inflation connection in a counterclockwise direction and check whether the valve is closed. Make certain there is perfect locking of the couplings of the inflation hose with the tent coupling and the blower. Start the blower and fill the tent until the maximum permitted operating pressure. The tent erects automatically. The safety valve integrated into the support frame avoids over-inflation. e.g. Tent blower 0.14-0.4 bar 230 V (Art. no. 1523017700) Note! Should parts of the support frame become caught up during erection then switch off the blower immediately and rectify the problem. Inflation can then be continued after doing this. Replace the cap after filling and tighten it by turning it in a clockwise direction. 4.2 Operation with compressed air Connect the pressure regulator with the knurled wheel on the compressed air bottle. Close the hand wheel (3) of the pressure regulator. Open the valve on the bottle (5) slowly. The manometer (1) indicates the pressure in the bottle. Adjust the output-pressure to approximately 10 bar using the adjustment wheel (4). The set pressure can be checked on the outlet-pressure gauge (2). Connect the air hose of the pressure regulator (6) with the brass coupling (7) of the inflation connection. Open the pressure regulator and start inflation. Observe the tent during the inflation process. Close the hand valve when the max. operating pressure is reached. Attention! With the PZ 17 Decon 2 L you must ensure that the connection hose is correctly connected between the tent frame and the shower tub Note! If, during erection of the tent, parts of the tent frame become caught up in the tent cover, then close the valve on the pressure regulator immediately and rectify the cause of the problem. After doing this, the inflation process can be continued. 5 1 2 3 6 4 7 Page 4/12

Vetter Pneumatic Decon Tents 4.3 Use as decontamination tent The water connection for the shower heads and the hand showers is positioned in the blue throughway opening and is a Storz Coupling Size D for water. The filling connection is positioned in the green throughway opening. Therefore this makes any confusion impossible with respect to the connections. 1 PZ 17 Decon 2 L: The tent is subdivided by 1 longitudinal partition into two lines. There are two each doors in the entrance awnings to enable entering the lines separately. The two shower units in the middle of the tent divide the tent into the undressing, showering and dressing areas. The continuous collecting basin prevents fluid from transgressing into the rest of the tent. The showers with the shower cap create a self-contained unit. 1 decon spray shower (1) and 1 decon brush-unit (2) each in the individual shower units provide optimal cleaning of the contaminated person. 2 PZ 40 3 L: The tent is divided into three lines using two longitudinal separation walls. There are three doors in the entry covers in order to separately enter each of the lines. The three shower units in the centre of the tent divide the tent into three areas: clothe removal area, shower area and the dressing area. Continuous shower tubs stop any liquid overflow into the remaining area of the tent. The showers with the shower covers form an enclosed unit. Two decon spray showers (1) and two decon brush-units (2) each in the individual shower units ensure optimum decontamination of contaminated persons. Page 5/12

Vetter PZ 17 Decon 2 L The Vetter decontamination path (PZ 40 3 L) 4.4 Instructions of the showers The required amount of water can be regulated via the ball valve (1). In order to change the shower curtains the hand showers (2) must firstly be uncoupled and the rubber washers (3) removed. The shower curtain can now be removed by separating the Velcro and pile fabric connections on the vertical support hose and unhooking the eyelets (4) on the insertion basin. 1 3 4 2 2 Page 6/12

Vetter Pneumatic Decon Tents 4.5 Deflation The deflation of the support frame happens over the inflation connection. To deflate the tent, close the air source (compressed air cylinder, etc.) and disconnect the pressure reducer or the filling hose of the blower. The deflation valve is opened by pressing-in and turning the pin (1) counter clockwise. Pin before locking Pressing-in + turning Valve open 1 1 2 3 Fold the tent in the way, that the air can escape (Folding to the direction of the inflation connection). Any remaining air can be removed with a vacuum adaptor (Item No.: 1700018300) in combination with an construction-site compressor adaptor (Item No.: 1600012000). Connect the construction-site compressor adaptor (1) to the coupling of the vacuum adaptor (2) and turn it interlocking. Then tighten the screwable part of t the vacuum adaptor. Now connect the constructionsite compressor adaptor to the support frame. Attach the quick-action coupling (3) to the connection hose of the pressure regulator and open the hand valve of the pressure regulator slowly. It is also possible to deflate the support frame with a blower with deflate function. Follow the operating instructions of the blower. After deflation and before packing, the valve must be unlocked again in order to guarantee perfect inflation when it is next used! Page 7/12

4.6 Folding Plan Before repacking, the tent frame and the frame of the shower must be completely empty. 1. The front of the tent is folded lengthwise in four equal sections. L Inflation connector Befüllanschlus Front Stirnseite 2. Then fold the tent five times in the direction of the inflation connector. 3. Now place the tent into the carrying bag. Page 8/12

Vetter Pneumatic Decon Tents 5. Practical Tips The individual separating walls, floor tarps, as well as the tent tarpaulins are removed easily and quickly if and as needed. Hook and loop fasteners are used to attach the tarpaulin to the pneumatic supporting frame. When using tent heaters, avoid blowing heat directly onto parts of the tent. If needed, lights can be suspended from the supporting frame. Additional tents are easily connected using hook and loop overlaps. After use, clean the tent with a mild cleanser before packing. Allow the parts to dry at normal room temperature. Treat outer surfaces with commercially available impregnating agents. Follow the instructions of the folding plan to fold and pack the tent. Make sure that the tent is folded and packed in an orderly manner and as instructed to ensure the tent is easy to unpack next time it is needed. 6. Storage When stored and handled properly, the properties of rubber products remain nearly constant for a long period of time. However when handled improperly and under unfavourable storage conditions, their physical properties and/or service life are shortened! Please comply with the following storage conditions: Store in a place that is cool, dry, dust-free and moderately ventilated. The storage temperature should be approx. 15 C; never let it exceed 25 C. The temperature should also not fall below -10 C. If there are heating appliances and heating conductors in the storage room, they must be appropriately insulated so that the temperature of 25 C is not exceeded. Maintain a minimum clearance between the heating appliances and the stored goods of 1 m. Do not store rubber products in moist storage rooms. The relative humidity should be less than 65 %. Protect the rubber products from light (direct exposure to sunlight, artificial light with high proportion of UV). The windows in the storage room need to be correspondingly darkened. Make sure that the storage room does not contain any appliances that cause ozone. Page 9/12

The storage room must be free of solvents, fuels, lubricants, chemicals, acids, etc. Store rubber products without pressure, tensile stress or similar distortions since that can promote deformations or crack development. Some metals such as copper and manganese can also have a damaging effect on rubber products. For more information please refer to DIN 7716. 7. Repeated Inspections The tents and their accessories should be subjected to a visual and functional inspection by a trained technician before and after each use but at least once a year. This requires inflating the tent to approx. 50 % of the max. working pressure (0.25 bar). Check all pressurized parts for fissures, cracks, cuts, puncture holes, detached spots, and heat or chemical damage. If the pressure does not experience a significant drop within one hour, the tent is ready for use. Please contact the manufacturer in case of larger damage or if you have any questions. Comply with DIN 7716 if storing the pneumatic universal tents long-term. 8. Repair Instructions Minor damage such as cracks, cuts, or punctures (max. 4 cm) can be repaired by the operator with the enclosed repair kit. Please follow these steps: 1. Select the size of the patch so that the patch extends approx. 4 cm beyond the damaged area on all sides. 2. Mark patch area on the supporting frame. 3. Roughen the area of the patch on the surface of the supporting frame as well as one side of the patch. 4. Apply a thin layer of the special adhesive to the roughened spot on the supporting frame and the roughened side of the patch. 5. Allow special adhesive to dry for approx. 10-15 minutes until no longer sticky. 6. Press patch firmly onto the pretreated area of the supporting frame and smooth out. 7. Allow unpressurized supporting frame to rest for at least 48 hours. Only the factory is able to repair damage that is more extensive. A trained technician must check the tent and its supporting frame for leaks after the repairs. Page 10/12

Vetter Pneumatic Decon Tents 9. Technical data Type PZ 17 Decon 2 L PZ 40 3 L * Article No. (Set) 1520047000 1520035500 Size outside (L x W x H) m 4.9 x 3.86 x 2.48 8 x 5.5 x 3.1 ft. 16,1 x 12.7 x 8.1 26.3 x 18 x 10.2 Size inside (L x W x H) m 4.9 x 3.5 x 2.3 8 x 5.1 x 2.9 ft. 16.1 x 11.5 x 7.6 26.3 x 16.7 x 9.5 Working pressure bar 0.5 0.5 psi 7.25 7.25 Test pressure bar 0.65 0.65 psi 9.4 9.4 Air requirement l 2,664 6,863 cu. ft. 94.1 242 Inflation time ca. sec 60 300 Pack size (L x W x H) m 1.1 x 0.85 x 0.6 1.1 x 0.95 x 1 ft. 3.6 x 2.8 x 2 3.6 x 3.1 x 3.3 Weight, approx. kg 105 212 lbs 231 467 * Also available as a 40 m² tent with 2 lines. PZ 40 2 L (1520048900) All rights reserved for technical changes within the scope of product improvement. Page 11/12

Place your trust in emergency pneumatics! We are the company who can help you, find a solution to your problem! Vetter GmbH A Unit of IDEX Corporation Blatzheimer Str. 10-12 D-53909 Zülpich Germany Sales Tel.: +49 (0) 22 52 / 30 08-0 Fax: +49 (0) 22 52 / 30 08-590 Mail: vetter.rescue@idexcorp.com www.vetter.de Article No. 87018005 Vetter GmbH I 09/17 I Changes and errors excepted. Made in Germany