Similar documents
Smallest Connector with Removable Contacts

CEELOK FAS-T CONNECTORS

2M Hermetic General Information. Why 2M Hermetic? GHEC 81. Amphenol s 2M Micro38999 Connector Series The New Aerospace Standard. Page Guide.

LSC19 Lighting Cable Assemblies and Connectors

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Couplings for Gates Hoses 7 Combination Nipple

Ground Clamps Cable Tray

Amphenol RF Interconnects TNC 31 Series Threaded Lock RF Connector System Materials

DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I

2M804 Push-Pull Crimp Receptacles Ordering Guide for 2M , 002, 003, 004

2M801 Dual-Start ACME Threads

Section N Micro-D Uni-Saver, Hardware and Accessories

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

SAP-3 Series FC HOUSING - for PC/Angled-PC -

Data Sheet for Precision Potentiometer

Aerospace. Light Weight and Flexible Qualified to Industry Standards. Fluid Conveyance

SAP-3 Series FC HOUSING - for PC/Angled-PC -

Data Sheet for Precision Potentiometer

Military Circular MIL-C-5015 catalogue Product Index

Flexible flue liner components Specifications

Blue Series Hot Melt Hose with RediFlext II Hanger System

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

CABLE GRIPS CABLE GRIPS

Installation guidelines street light poles from Sapa with ground piece

Integrated Process Solutions

2-3-5 Valve Manifolds

Emergency Stop Devices

Preparation and Installation of the (VPC) Flat Circular Vent Panel

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL

EcON-O-fit HOSE clamps

Southco 64 Push-to-Close Latch Visible, Locking, Slide Bolt

ACCESSORIES 5:05 5:05 PRODUCT CATALOGUE 189

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).

RTA flexible conduits

TruDesign Aquavalve (Y Valve)

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information

Preparation and Installation of the (VPR) and (VPS) Rectangular and Square Vent Panels

Agilent Ultimate Union Kits (G and G )

Installation and Maintenance Manual

Railing & Wall Mount Storage Systems

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

Installation & User Manual EW5000 Outdoor Cooking Fire

D. S. HULL COMPANY, INC

Wenger Corporation 2014 Printed in USA 05/14 Part #049B015-09

Installation and operation instructions for KINEMAX burners

Advanced Customization Type 1. White Paper

get connected with Bradford fittings & valves Bradford Company, Inc

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Operating Instructions

OAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits

Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120

Pressure relief valve VRH 5 / VRH 30 / VRH 60 / VRH 120

TROLLEY-MOUNTED HOSE REELS

Russellstoll. Electrical Interconnection Systems. Dura-Gard Nonmetallic Waterproof Connections. The Next Generation: Dura-Gard

AND LOAD CANOPY RACK SPECIFICATIONS

AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators

Table and Furniture Base Fittings Furniture Feets

Hooks & Multiracks. Group 11 Door & Specialised Hardware AL8253AS AL8722AS 8025SS AL8102AS AL8104AS

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

Cover, 1 Gang; Malleable Iron; Zinc Electroplated Dichromate Aluminum Polymer Enamel; Box Mounting; Appleton[R] Brand; FS Model; With Square Handle

Precision Pliers. Mini Lineman's Plier. Long Nose Plier. Needle Nose Plier. Diagonal Cutting Plier. PM-754 Flat Nose Plier PM-755 Bent Nose Plier

MS20663 and MS NAS1435E and NAS1435K

TUCSON PATIO AWNING INSTALLATION MANUAL

Safety. BBA Compliance Kit Multi-Pro 5800 Turf Sprayer Model No Installation Instructions

85 Heart Lake Road South Brampton, Ontario, Canada L6W 3K2 Phone: Fax:

S E L E C T I O N. Abdominal Crunch. User manual

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

EDITION

Tuf-Lite and Tuf-Lite II Fans 6000 Series Hub

1000M MANUAL Signature Series Slicer OPERATORS MANUAL

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

Model Number Structure

ANACONDA SEALTITE CONDUIT TYPE NMFG BLUE

Ely Cagliari. for installation

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

T&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings

POP-UP OPTION USER HARDWARE MANUAL. EdgeTech 4 Little Brook Road West Wareham, MA _REV_B 8/29/2018

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

STRAIGHT BLADE RECEPTACLES

FIBER OPTIC CLOSURES

D-SUB SERIES. Fast Locking System ESCC 3401/085. Features and Benefits. Typical Applications. Specification. Quality Level.

DEFENSE LOGISTICS AGENCY LAND AND MARITIME P.O. BOX 3990 COLUMBUS, OHIO

Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves

Section 11 Workstation Components

SHOPFITTING. Grooved panel 664. Grooved panel accessories 665. Cash drawers 668. Partition hardware 675. Toilet partitions 686

SH, MP, HP, EZ-SH, EZ-MP, EZ-HP Series Design Features & Benefits COXREELS. SH, MP, HP, EZ-SH, EZ-MP, & EZ-HP Series Design Features

ALPINE SLIDEOUT COVER

A11.15 HANDLES AND LOCKCASES A11 TURN-TILT WINDOWS

SIZE RANGE: 1 TO 10. PRESSURE RANGE: FULL VACUUM TO 275 psi

Dual-Lock. dixonvalve.com Customer Service:

INSTALLATION GUIDELINES

Tuf-Lite III Fans 4000KW Series Hub

Content. Type SIL100 Ultra-pure silicone hose 4. Type SIL200 Fabric-reinforced silicone hose 6. Type SIL300 Wire-reinforced silicone hose 8

Molded High-Voltage Bushing Wells

a Nexans company Catalogue 2009

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Form No.: LITPLUMBPAK1/2007AD 2005 Plumb Pak Printed in the U.S.A.

Transcription:

tttttt www.wealdelectronics.com This publication is issued to provide outline information only and unless specifically agreed to the contrary by WEALD ELECTRONICS LTD. in writing, is not to form part of any order or contract or be regarded as a representation relating to the products or services concerned. WEALD ELECTRONICS LTD. reserve the right to alter without notice the product design, price or conditions of supply of any product or service. Whilst every effort has been made to ensure that the information contained in this catalogue is accurate, no responsibility can be accepted for any errors or omissions nor for the effects of such errors or omissions. 2

MOTORSPORT CONNECTOR ACCESSORIES CONTENTS Section 1: LMD7003/7004 series Protective caps General information and characteristics...... 3 Protective cap styles....... 4 Dimensions and ordering information........ 5, 6 Section 2: LMA8684 Series Nut plates General information and characteristics......... 7 Dimensions and ordering information....... 8 Section 3: LMA8688 Series Gaskets General information and characteristics......... 9 Dimensions and ordering information........ 10 Product Safety Information........... 11 This publication is issued to provide outline information only and unless specifically agreed to the contrary by WEALD ELECTRONICS LTD. in writing, is not to form part of any order or contract or be regarded as a representation relating to the products or services concerned. WEALD ELECTRONICS LTD. reserve the right to alter without notice the product design, price or conditions of supply of any product or service. Whilst every effort has been made to ensure that the information contained in this catalogue is accurate, no responsibility can be accepted for any errors or omissions nor for the effects of such errors or omissions. 2

LMD7003/7004 SERIES PROTECTIVE CAPS GENERAL INFORMATION Designed for bayonet coupling circular Autosport / Motorsport connectors, derived from MIL-DTL-38999 and JN1003 Ultra-lightweight design (up to 40% lighter than current design*) Corrosion resistant aluminium body Anti-vibration locking design Shell machined from solid material for reliable strength and performance Available with or without flexible stainless steel micro wire rope lanyards 3D models in all major CAD formats available CHARACTERISTICS Shell material Shell finish (standard) Gasket material Rope material Fastener materials Operating temperature Sealing * - depends on shell size and style Machined aluminium alloy Hard black anodising Silicone elastomer or Neoprene rubber Stainless Steel Copper and Kynar -55 C to +175 C Mated caps to IP67 PROTECTIVE CAPS FOR OTHER CONNECTORS AVAILABLE, INCLUDING MIL-DTL-38999 AND MIL-DTL-26482 STYLES 3

LMD7003/7004 SERIES PROTECTIVE CAPS STYLES AVAILABLE LMD7003 SERIES - PROTECTIVE CAPS FOR PLUG CONNECTORS PART NUMBER PROTECTIVE CAP STYLE SIZE 01 TO 06 SIZE 08 TO 24 LMD7003-**-00-005 Without Lanyard M SIZE 01 TO 06 SIZE 08 TO 24 LMD7003-**-0*-335 With Stainless Steel Lanyard LMD7004 SERIES - PROTECTIVE CAPS FOR RECEPTACLE CONNECTORS PART NUMBER PROTECTIVE CAP STYLE SIZE 01 TO 06 SIZE 08 TO 24 LMD7004-**-00-005 Without Lanyard SIZE 01 TO 06 SIZE 08 TO 24 LMD7004-**-0*-335 With Stainless Steel Lanyard * - denotes size. For dimensions and more ordering information see pages 5 and 6. 4

LMD7003/7004 SERIES PROTECTIVE CAPS DIMENSIONS AND ORDERING INFORMATION LMD7003 SERIES - PROTECTIVE CAPS FOR PLUG CONNECTORS www.wealdelectronics.com SIZE 01 TO 06 SIZE 08 TO 24 PART NO. EXAMPLE LMD7003 06(A) 02 33 5 WEALD SERIES PLATING (TABLE 4) SHELL SIZE (TABLE 1) LANYARD TYPE (TABLE 3) LANYARD LENGTH (TABLE 2) TABLE 1 SHELL Ø A ± 0,15 B ± 0,15 WEIGHT [g±10%] [mm] [mm] (WITHOUT LANYARD) 01 9.00 9.00 0.52 02 10.60 9.00 0.66 04 12.50 9.20 0.90 06A* 13.00 10.00 1.00 06 13.90 10.00 1.30 08 14.50 18.80 2.35 10 17.40 18.80 2.75 12 21.90 18.80 4.10 14 25.00 17.90 4.85 16 28.20 17.90 5.90 18 31.40 17.90 8.25 20 34.60 17.90 9.50 22 37.70 17.90 11.00 24 40.90 17.70 12.71 * - 06A cap mates with size 06-05 connectors. TABLE 2 REF. NO C ± 8 - LANYARD LENGTH [mm] STD FOR SHELL SIZE 00 NO LANYARD N/A 02 80 01 TO 06 03 125 08, 10 04 140 12 TO 18 05 150 22, 24 OTHER LENGTHS AVAILABLE ON REQUEST TABLE 3 REF. NO LANYARD AND ATTACHMENT TYPE 00 NO LANYARD 33 STAINLESS STEEL WIRE ROPE WITH FERRULES OTHER TYPES AVAILABLE ON REQUEST TABLE 4 REF. NO PLATING 5 HARD BLACK ANODISING OTHER VARIANTS AVAILABLE ON REQUEST 5

LMD7003/7004 SERIES PROTECTIVE CAPS DIMENSIONS AND ORDERING INFORMATION LMD7004 SERIES - PROTECTIVE CAPS FOR RECEPTACLE CONNECTORS www.wealdelectronics.com SIZE 01 TO 06 SIZE 08 TO 24 PART NO. EXAMPLE LMD7004 06(A) 02 33 5 WEALD SERIES PLATING (TABLE 4) SHELL SIZE (TABLE 1) LANYARD TYPE (TABLE 3) LANYARD LENGTH (TABLE 2) TABLE 1 SHELL Ø A ± 0,15 B ± 0,15 WEIGHT [g±10%] [mm] [mm] (WITHOUT LANYARD) 01 10.10 8.60 0.58 02 11.80 8.70 0.85 04 14.10 10.50 1.45 06A* 14.90 10.20 1.58 06 15.80 10.10 1.75 08 18.10 12.50 3.10 10 21.50 12.50 4.20 12 26.30 12.50 5.85 14 29.50 12.50 7.25 16 32.70 12.50 8.55 18 35.90 12.50 9.95 20 39.10 12.50 11.60 22 42.20 12.50 12.95 24 45.50 13.30 15.05 * - 06A cap mates with size 06-05 connectors TABLE 2 REF. NO C ± 8 - LANYARD LENGTH [mm] STD FOR SHELL SIZE 00 NO LANYARD N/A 02 80 01 TO 06 03 125 08, 10 04 140 12 TO 18 05 150 22, 24 OTHER LENGTHS AVAILABLE ON REQUEST TABLE 3 REF. NO LANYARD AND ATTACHMENT TYPE 00 NO LANYARD 33 STAINLESS STEEL WIRE ROPE WITH FERRULES OTHER TYPES AVAILABLE ON REQUEST TABLE 4 REF. NO PLATING 5 HARD BLACK ANODISING OTHER VARIANTS AVAILABLE ON REQUEST 6

LMA8684 SERIES NUT PLATES GENERAL INFORMATION Designed for two-hole oval flange mounted receptacle Autosport / Motorsport connectors derived from MIL-DTL-38999 and JN1003 Speed up connector installation in hard-to-reach locations Anti-vibration / self-locking design Lightweight and corrosion resistant Available in 16 sizes 3D models in all major CAD formats available CHARACTERISTICS Shell material Aluminium alloy Shell finish Anodised to MIL-A-8625F Type II Cl. 2 Nut material Stainless Steel 303 Nut finish Operating temperature Dry-film Lubricant -65 C to +175 C 7

LMA8684 SERIES NUT PLATES DIMENSIONS AND ORDERING INFORMATION SHELL SIZE PART NUMBER THREAD SIZE A ± 0,15 [mm] WEIGHT [g] 01 LMA8684-01-20-00 M2 12.00 0.29 02 LMA8684-02-20-00 M2 15.30 0.30 02 LMA8684-02-25-00 M2.5 15.30 0.32 04 LMA8684-04-20-00 M2 16.20 0.33 04 LMA8684-04-25-00 M2.5 16.20 0.35 06 LMA8684-06-25-00 M2.5 18.00 0.38 07 LMA8684-07-00-00 M3 19.80 0.57 08 LMA8684-08-00-00 M3 21.40 0.60 10 LMA8684-10-00-00 M3 25.90 0.63 12 LMA8684-12-00-00 M3 29.10 0.70 14 LMA8684-14-00-00 M3 32.50 0.72 16 LMA8684-16-00-00 M3 34.80 0.74 18 LMA8684-18-00-00 M3 38.20 0.79 20 LMA8684-20-00-00 M3 41.60 0.81 22 LMA8684-22-00-00 M3 45.00 0.91 24 LMA8684-24-00-00 M3 49.50 1.01 Recommended tightening torques* M2.0 20cNm (recommended), 30cNm (max) M2.5 40cNm (recommended), 60cNm (max) M3.0 60cNm (recommended), 90cNm (max) * - for guidance only, depend on fixings and mounting method. 8

LMA8688 SERIES GASKETS GENERAL INFORMATION Designed for two-hole oval flange mounted receptacle Autosport / Motorsport connectors derived from MIL-DTL-38999 & JN1003 Made from fluoroelastomer rubber Resistant to degradation through exposure to most motorsport fluids* Long-term sealing performance Available in 14 sizes 3D models in all major CAD formats available CHARACTERISTICS Material Continuous operating temperature Maximum operating temperature Fluoroelastomer rubber (Viton) -20 to +200 C +300 C * Note: Not recommended for long term immersion in fuels containing MEOH, ETOH, MTBE. etc. 9

LMA8688 SERIES GASKETS DIMENSIONS AND ORDERING INFORMATION SHELL SIZE PART NUMBER A ± 0,25 [mm] Ø B ± 0,20 [mm] Ø C ± 0,25 [mm] 01 LMA8688-01-00-00 12.00 7.00 2.20 02 LMA8688-02-00-00 15.30 8.80 2.70 04 LMA8688-04-00-00 16.20 10.50 2.70 06 LMA8688-06-00-00 18.00 12.05 2.70 07 LMA8688-07-00-00 19.80 12.35 3.20 08 LMA8688-08-00-00 21.40 12.50 3.20 10 LMA8688-10-00-00 25.90 15.50 3.20 12 LMA8688-12-00-00 29.10 19.55 3.20 14 LMA8688-14-00-00 32.50 22.72 3.20 16 LMA8688-16-00-00 34.80 25.90 3.20 18 LMA8688-18-00-00 38.20 29.07 3.20 20 LMA8688-20-00-00 41.60 32.25 3.20 22 LMA8688-22-00-00 45.00 35.40 3.20 24 LMA8688-24-00-00 49.50 38.60 3.80 10

PRODUCT SAFETY INFORMATION These notes are intended to be used in conjunction with the Product Catalogue and Product Specification. Products may be safely used in the applications for which they have been designed and within the specified rating and environments. If products are exposed to conditions outside the performance ratings or specified environments they may constitute a hazard. In particular it should be noted that:- 1. Material Content Circular Connectors generally use metalwork parts made of brass, aluminium, phosphor-bronze or steel, which, dependant on the particular application, may be passivated and protected with cadmium or zinc plate in conjunction with chromated or anodised surface finishes. The insulating materials can either be natural or synthetic rubber, together with plastic or glass-filled plastic moulded parts. Contact materials vary but are usually made of brass, phosphor-bronze, alumel or chromel. 2. Electric Shock, Burns and Fire Hazard can occur if the product is used outside the specified parameters or if the product is damaged, wrongly wired, poorly assembled, poorly integrated into larger equipment, or contaminated with conductive fluids. Live circuit terminations must be protected and live circuits never broken by disconnecting products. Hot spots may be created when resistance is increased due to damage or incorrect integration particularly soldering, or loose terminations. Overheating can cause breakdown of insulation, electric shock, burns or, ultimately, fire. In the event of fire noxious and/or toxic fumes may be released and, in these circumstances, any fire involving the product should be dealt with by personnel properly equipped. Connectors with exposed terminations or contacts should not be used on the current supply side of a circuit with exposed contacts on an unmated product. Before making a circuit live, the product and wiring should be checked to ensure there is no electrically conducting debris present. Circuit resistance checks should also be conducted before making the circuit live. Always ensure that connectors are assembled and wired by properly trained personnel. 3. Use, Transport and Storage of Products Care must be exercised to avoid damage to any part of the products during transporting, storage or use. Abnormal transit or storage conditions and abuse during installation can give rise to damage. Products should not be used in a damaged condition. Improper storage (particularly of damaged products) can give rise to additional hazards particularly corrosion. Attention is specifically drawn for the proper storage of products containing cadmium and you are advised to see the Guidance Note from the Health and safety Executive on Cadmium Health and Safety Precautions. 4. Disposal of Products Product should not be burnt. SAFETY RULES 1. FOLLOW THE GUIDELINES GIVEN. 2. ALWAYS PROTECT LIVE CIRCUITS AND NEVER DISCONNECT A LIVE CONNECTOR. 3. NEVER USE A DAMAGED CONNECTOR. 4. NEVER BURN DISCARDED CONNECTORS. 11