Rev2.0-7 October 2011

Similar documents
A-100- Rev7-28 June Head Office: Perth, Western Australia. Machine Condition Monitoring Structural Dynamics

CUMULATIVE NOISE IMPACT ASSESSMENT FOR THE STRATEGIC PROPOSAL

U-Park Wyatt Street Temporary Event Space

Northeast Stoney Trail In Calgary, Alberta

> Aircraft Noise. Bankstown Airport Master Plan 2004/05 > 96

BHP Billiton Iron Ore Section 46 Amendment to Ministerial Statement 433 Upgrade Dust Management at Finucane Island and Nelson Point, Port Hedland

Project No Brent Cross, Cricklewood London, UK Phase 1A North RMA

27 January Stayover by Ausco 44 Formation Street Wacol QLD Dear Myke,

BHP Billiton Iron Ore. Asset Development Projects

BHP Billiton Iron Ore Western Australia. Iron Ore. Port & Rail Operations. Mick Evans Vice President Port & Rail

BHP Billiton Iron Ore Western Australia. Iron Ore. Presentation to Analysts June Ian Ashby, President and COO BHP Billiton Iron Ore

Aircraft Noise. Why Aircraft Noise Calculations? Aircraft Noise. SoundPLAN s Aircraft Noise Module

CHRISTCHURCH INTERNATIONAL AIRPORT NOISE MANAGEMENT PLAN. 28 March 2014 V10

SUBMISSION BY THE BOARD OF AIRLINE REPRESENTATIVES OF NEW ZEALAND ON THE DRAFT QUEENSTOWN LAKES DISTRICT COUNCIL DRAFT PLAN

DETERMINATION OF SOUND POWER LEVELS OF A TRANSFORMER AND A REACTOR

BHP Billiton Scope 3 emissions

AUCKLAND INTERNATIONAL AIRPORT MASTERPLAN

Noise Oversight Committee

CAPABILITY STATEMENT

SOUTH CAMBRIDGESHIRE DISTRICT COUNCIL. Executive Director / Senior Planning Policy Officer

Section 11 Social Impact Assessment

Review of Environmental Factors

3 Pilbara ports provide gateways

Part 150 and Part 161: Purpose, Elements, and Process

West Gate IAC Hearing. Review of vibration and regenerated noise from construction

APPENDIX 3: Acoustic Assessment (Hegley Acoustic Consultants)

Perth Noise Abatement Procedures - Change to Preferred Runways

- A Growth Story. Michiel Hovers Vice President, Iron Ore Marketing 28 th February 2012

London Borough of Barnet Traffic & Development Design Team

BHP Billiton Iron Ore Western Australia. Iron Ore. Mining Operations. Phil Price Vice President Integrated Planning

Measuring, Managing and Mitigating Aircraft Related Noise

CHAPTER 6 NOISE EXPOSURE

Environmental Assessment. Runway 14 Runway 14 southern departures trial Gold Coast Airport

LAX Community Noise Roundtable. Aircraft Noise 101. November 12, 2014

Potomac River Commuter Ferry Feasibility Study & RPE Results

E40. Temporary activities

AERODROME METEOROLOGICAL OBSERVATION AND FORECAST STUDY GROUP (AMOFSG)

REVIEW OF GOLD COAST AIRPORT Noise Abatement Procedures

Iron Ore Update. Ian Ashby President Iron Ore 6 May 2009

BRIEFING PAPER APRIL 2002 MINING AREA C DEVELOPMENT PORT HEDLAND PORT & CAPACITY EXPANSION

Noise Management of Aircraft Operations at Airports.

Runway 35 South & West (Jet) Departure Flight Path Amendment

Dublin Airport - Noise Management Plan

Longmont to Boulder Regional Trail Jay Road Connection DRAFT FINAL REPORT

URBIS STORAGE INDEX 31 DECEMBER 2017 RELEASED MARCH

WELCOME! FORT LAUDERDALE-HOLLYWOOD INTERNATIONAL AIRPORT 14 CFR PART 150 NOISE AND LAND USE COMPATIBILITY STUDY

AERODROME LICENCE APPLICATION PROCESS

Provincial Railway Technical Standards

1.0 OUTLINE OF NOISE ANALYSIS...3

Environment and Climate Change Unit

BHP BILLITON IRON ORE PTY LTD

Environmental Assessment. Runway 14 Smart Tracking Approach Gold Coast Airport

NOISE AND FLIGHT PATH MONITORING SYSTEM BRISBANE QUARTERLY REPORT OCTOBER - DECEMBER 2013

NOISE AND FLIGHT PATH MONITORING SYSTEM BRISBANE QUARTERLY REPORT JULY - SEPTEMBER 2011

Final. Hydroacoustic and Airborne Monitoring at the Naval Station. Mayport Interim Report June 2015

PSP 75 Lancefield Road. Northern Jacksons Creek Crossing Supplementary Information

Perth Airport. Runway 21 Night-Time Departure Trial Proposal. Environmental Analysis Summary. August Airservices Australia 1 of 17

NOISE AND FLIGHT PATH MONITORING SYSTEM MELBOURNE QUARTERLY REPORT OCTOBER - DECEMBER 2012

NOISE AND FLIGHT PATH MONITORING SYSTEM MELBOURNE QUARTERLY REPORT JULY - SEPTEMBER 2011

NOISE AND FLIGHT PATH MONITORING SYSTEM MELBOURNE QUARTERLY REPORT JULY - SEPTEMBER 2013

NUMBER 6_2 A free monthly photo e Mag of railway happenings in WA during June 2018

ICAN INSTRUCTION FOR THE CALCULATION OF AIR- CRAFT NOISE AND FOR NOISE MAPPING AROUND AIRPORTS

Birmingham Airport Airspace Change Proposal

Technical Documentation Wind Turbine Generator Systems with LNTE 50 Hz and 60 Hz

Metropolitan Planning Authority 25-Jul Thompsons Road, Clyde Creek and Casey Fields South (Residential) PSPs 53, 54 & 57.1 Transport Modelling

Treasure Island Supplemental Information Report Addendum

Queen s Circus Roundabout

Atlas Lifts Production Guidance and Lowers Cost Forecast After Record September Quarter

Non-technical summary

REVIEW OF PERTH AIRPORT Noise Abatement Procedures

Heathrow Community Noise and Track-keeping Report: Burhill

East West Rail Consortium

Newcastle Transport Program Newcastle Light Rail Determination Report

Perth Airport Aircraft Noise Validation Study Terms of Reference

APPENDIX C NOISE ANALYSIS

STANSTED AIRPORT PLANNING APPLICATION UTT/18/0460/FUL SECTION 106 CONDITIONS TO BE REQUIRED IF PLANNING APPLICATION IS APPROVED

THRESHOLD GUIDELINES FOR AVALANCHE SAFETY MEASURES

INVITATION FOR EXPRESSION OF INTEREST

Supporting information to an application for preapplication 3 rd February 2017

Review of brisbane Airport Noise Abatement Procedures

29 December Canada Transportation Act Review Secretariat 350 Albert Street Ottawa ON K1A 0N5

5 Rail demand in Western Sydney

Union Station Rail Corridor East

PLUME RISE ASSESSMENTS

MARSHALL Subdivision. Township of Springwater, County of Simcoe. Traffic Brief for: Ontario Inc. Type of Document: Final Report

PREFACE. Service frequency; Hours of service; Service coverage; Passenger loading; Reliability, and Transit vs. auto travel time.

FLIGHT OPERATIONS PANEL (FLTOPSP)

Submission to Infrastructure Victoria s Draft 30-Year Infrastructure Strategy

Draft Greater Sydney Region Plan

The following criteria shall be applied within the boundaries of the AO District:

Draft Concept Alternatives Analysis for the Inaugural Airport Program September 2005

STAFF REPORT. Airport Land Use Plan Consistency Review: Old Town Village Mixed Use Project City of Goleta. MEETING DATE: June 18, 2015 AGENDA ITEM: 5M

Re: Review of Heathrow s noise mitigation schemes: A Heathrow Airport consultation 9 May to 1 August 2011

Evaluation of Alternative Aircraft Types Dr. Peter Belobaba

AIRSERVICES AUSTRALI A

STAFF REPORT. Airport Land Use Consistency Determination Betteravia Plaza. MEETING DATE: January 21, 2016 AGENDA ITEM: 8D

GREATER GEELONG PLANNING SCHEME PROPOSED AMENDMENT FOR THE PROTECTION OF EMERGENCY MEDICAL SERVICE HELICOPTER FLIGHTPATHS SERVING GEELONG HOSPITAL

GRAVITY ROLLER COASTER LAUNCH COASTER

HEPPEW#PSZI#JMIPH. 534##He}0Rmklx#Eziveki#Wsyrh#Pizip#Gsrxsyvw. LQQL#Vitsvx#Rs1#63;74" %(/2(,'(0 ;89$ Tvitevih#jsv>

Whangarei Airport. Prepared by Carine Andries 10/20173

Transcription:

OUTER HARBOUR DEVELOPMENT RAIL NOISE ASSESSMENT : WESTERN SPUR BHP BILLITON IRON ORE 075063-72-100-Rev2.0-7 October 2011 www.svt.com.au Head Office: Perth, Western Australia Acoustics Corrosion Kuala Lumpur, Malaysia Performance Monitoring Vibration Melbourne, Australia Advanced Engineering Services R&D Training Machine Condition Monitoring Structural Dynamics

DOCUMENT CONTROL & REVIEW INFORMATION Client: Client Contact: BHP Billiton Iron Ore Sonja Marvick SVT Contact: SVT Office: Granger Bennett Perth SVT Job No: 075063 SVT Document No: 075063-72-100-Rev2.0-7 October 2011 Rev Description Prepared Reviewed Date 2.0 First Issue Maya Maoref Granger Bennett 7 October 2011 1.0 First Issue Maya Maoref Granger Bennett 5 October 2011 SVT Engineering Consultants ABN: 18 122 767 944 SVT Perth (HEAD OFFICE) SVT Kuala Lumpur Office SVT Melbourne Office 112 Cambridge Street West Leederville WA 6007 Australia SVT-Engineering Malaysia Sdn Bhd (Malaysian Office) 62A, Jalan Badminton 13/29, Tadisma Business Centre, 40100 Shah Alam, Selangor, Malaysia Suite 1, 20 Cato Street Hawthorn East VIC 3123 Australia Tel: (61) 8 9489 2000 Fax: (61) 8 9489 2088 Email: mailbox@svt.com.au Tel: +60 3 5513 6487 (h/p 012 330 1071) Fax: +60 3 5513 6486 Email: mailbox@svt.com.au Tel: +61 3 9832 4406 Fax: +61 3 03 9917 2204 Email: mailbox@svt.com.au Doc: 075063-72-100-Rev2.0-7 October 2011 Page I

EXECUTIVE SUMMARY SVT was requested by BHP Billiton Iron Ore to provide an assessment of the impact of rail noise on the town of South Hedland and Green Acres as a result of the BHP Billiton Iron Ore s Outer Harbour Development expansion activities. The aim of this document is to assess the impact of rail noise on South Hedland as a result of the Outer Harbour Development Stage 1 to stage 4 expansion with respect to the State Planning Policy 5.4 Road and Rail Transport Noise and Freight Considerations in Land Use Planning (SPP 5.4) gazetted in September 2009. ROAD AND RAIL TRANSPORT POLICY Rail and road noise management in Western Australia is implemented through the state planning policy 5.4 Road and Rail Transport Noise and Freight Considerations in Land Use Planning (22 Sept 09) which operates under the Planning and Development Act 2005. The state planning policy specifies a noise target and a noise limit. For major or minor redevelopments, the noise criteria (Table E- 1) in the policy need not be applied, but instead should be used as guidance. Table E- 1 Planning Policy Noise Criteria Time of day Noise Target Noise Limit Day (6am 10pm) L Aeq(Day) = 55dB(A) L Aeq(Day) = 60dB(A) Night (10pm 6am) L Aeq(Night) = 50dB(A) L Aeq(Night) = 55dB(A) The 5dB difference between the outdoor noise target and the outdoor noise limit represents an acceptable margin for compliance. The policy recognises that in a number of instances it may not be reasonable and practicable to meet the noise target. Where transport noise is above the target level, measures are expected to be implemented that best balance reasonable and practicable considerations, such as noise cost/benefit, feasibility, community preferences, amenity impacts, safety, security and conflict with other planning and transport policies. In these cases the community should also be consulted to assist in identifying best overall solutions. RAIL NOISE MODEL An acoustic model has been developed using the SoundPlan noise modelling program. Rail noise was modelled from the main line (south of South Hedland) to Finucane Island as presented in Figure E- 1. Doc: 075063-72-100-Rev2.0-7 October 2011 Page II

Figure E- 1 Location of Rail Line near South Hedland and Closest Receivers The new planning policy does not specify meteorological conditions to be applied to the noise model. Therefore, the noise modeling results have been calculated using worst case meteorological conditions as outlined in the Environmental Protection Authority (EPA) Draft Guidance Note No.8. Two noise sensitive receivers located on the southern boundary of South Hedland and one receiver on the southern side of the rural village Green Acres have been defined as closest receivers to the western spur rail line. These receivers (Green Acres, SH West and SH South) are shown in Figure E- 1. Table E- 2 presents the number of rakes per day to and from Nelson Point, Finucane Island and Boodarie port facilities for each stage of BHP Billiton Iron Ore expansions. Doc: 075063-72-100-Rev2.0-7 October 2011 Page III

Table E- 2 Noise Model Configuration Number of rakes entering and exiting for each expansion Rakes PHIHP 240MTpa OHD Stage 1-5 Nelson Point Total rakes per day (loaded and unloaded) 48 Finucane Island (Goldsworthy Line) Total rakes per day (loaded and unloaded) 40.6 Boodarie Total rakes per day (loaded and unloaded) 240 MTpa RESULTS The predicted received noise levels at each sensitive receiver are presented in Table E- 3. All results include the applicable 2.5dB façade correction factor 1. Table E- 3 Noise Modelling Results at South Hedland Receivers for PHIHP and Outer Harbour Expansion Project Receiver South Hedland W South Hedland S Green Acres PHIHP 32.0 33.9 30.1 Outer Harbour Development Stage 1 Outer Harbour Development Stage 2 Outer Harbour Development Stage 3 Outer Harbour Development Stage 4 32.3 34.1 30.9 32.5 34.2 31.5 32.8 34.3 32.1 33.1 34.4 32.6 As can be seen from the table the received noise at all receivers is below the noise target of L Aeq 50dB(A). 1 See section 3.1 (page 5) of the Implementation Guidelines for State Planning Policy 5.4 Road and Rail Transport Noise and Freight Considerations in Land Use Planning. Doc: 075063-72-100-Rev2.0-7 October 2011 Page IV

TABLE OF CONTENTS DOCUMENT CONTROL & REVIEW INFORMATION... I EXECUTIVE SUMMARY... II ROAD AND RAIL TRANSPORT POLICY... II RAIL NOISE MODEL... II RESULTS IV TABLE OF CONTENTS... 1. INTRODUCTION... 1 1.1 Aim... 1 1.2 Scope of Work... 1 1.3 Location of South Hedland and Green Acres... 1 1.4 Rail Operations General Overview... 2 1.4.1 Previous Modelling... 2 1.4.2 Outer Harbour Development Rail Configuration... 2 2. APPLICABLE REGULATIONS... 2 2.1 Application of State Planning Policy 5.4 to Outer Harbour Development... 3 3. NOISE MODELLING... 4 3.1 Rail Noise Impacts... 4 3.2 Noise Model Software... 4 3.3 Methodology... 4 3.3.1 Measured Noise Levels Site Field Measurements... 5 3.3.2 Rail Model Overview... 7 3.3.3 Meteorological Conditions Applied... 7 3.4 Rail Movements... 7 4. RESULTS... 8 4.1 Noise Modelling Results... 8 APPENDIX A : RAIL NOISE MODEL LAYOUT... A-1 Doc: 075063-72-100-Rev2.0-7 October 2011 Page

1. INTRODUCTION SVT was requested by BHP Billiton Iron Ore to assess the impact of rail noise on the town of South Hedland and Green Acres as a result of the BHP Billiton Iron Ore Outer Harbour Expasion activities. The Outer Harbour Development Stage 1 to stage 4 expansion project requires the development of the Western Spur rail line on the southern and western sides of South Hedland and Green Acres in order to meet the expected tonnage of ore for this rail corridor. 1.1 Aim The aim of this document is to assess the impact of rail noise on South Hedland and Green Acres as a result of the Outer Harbour expansion with respect to State Planning Policy 5.4 Road and Rail Transport Noise and Freight Considerations in Land Use Planning gazetted in September 2009. 1.2 Scope of Work SVT has undertaken field measurements and a desktop noise model in order to assess the impacts of rail noise on the town of South Hedland and Green Acres. 1.3 Location of South Hedland and Green Acres South Hedland is comprised primarily of private residences with a central shopping and office district which is zoned as a commercial area. South Hedland is some 9 km south of Port Hedland as shown in Figure 1-1. Green Acres is a rural village situated to the South of South Hedland. Figure 1-2 shows the location of the sensitive receivers used in this assessment. 9 km Figure 1-1 South Hedland Location Doc: 075063-72-100-Rev2.0-7 October 2011 Page 1

Figure 1-2 Location of Rail Line near South Hedland and Closest Receivers 1.4 Rail Operations General Overview Current rail operations in Port Hedland consist of rail movements along the main line to either Finucane Island or Nelson Point. Trains into and out of these two port facilities consist of multiple rakes, where each rake consists of two locomotives and 120 ore cars. The trains are broken into individual rakes at either Bing Siding or the Nelson Point holding area before entering the car dumpers where the ore cars are offloaded. The offloaded ore cars are then reconstituted into multi rake trains at either Bing Rail Yard or Nelson Point departure yard. Trains bound for Finucane Island are broken into individual rakes at Bing Siding. Once broken the single rake trains travel from the Bing Siding through the Goldsworthy Junction, passing north of South Hedland, along the Goldsworthy Line to the Boodarie Rail Yard. From the Boodarie Rail Yard the trains continue on to Car Dumper 4 (CD4) at Finucane Island. Once the ore cars have been emptied the train moves from CD4 back to Boodarie. At this point the ore cars inspected for any defects prior to returning to the main line. Both loaded and unloaded trains pass-by South Hedland en-route to and from the Finucane Island load out facility. There is only 1 rail line into and out of Finucane Island and therefore the number of loaded and unloaded trains passing South Hedland is always equal. 1.4.1 Previous Modelling Rail modelling has been undertaken for the BHP Billiton Iron Ore Main line, Goldsworthy rail line, Nelson Point and Finucane Island for RGP5 2 and RGP6 3 expansions. The number of rail movements has not changed between RGP6 and the Port Hedland Inner Harbour Project (PHIHP) and as a result a rail noise assessment was not undertaken for PHIHP as the received levels for PHIHP are the same as for RGP6. PHIHP is referred to in this document as it is the latest approved expansion in Port Hedland. The PHIHP received noise levels referred to in the document are RGP6 noise levels. 1.4.2 Outer Harbour Development Rail Configuration For each expansion project a defined tonnage of ore is expected to be transported to the port facilities at Nelson Point and Finucane Island. The total tonnage of ore and number of rakes required to transport that ore for each growth project are outlined in Table 1-1. The proposed western spur rail line for the outer harbor development will leave the main line south of Green acres and will pass to the south of South Hedland with the rail loop ending in Boodarie yard as shown in Figure 1-2. Table 1-1 shows the number of rakes to be transported to Nelson Point and Finucane Island port facilities for each stage of expansion. 2 SVT Document Rpt02A 075063, Port Hedland Noise Assessment Report for RGP5 3 SVT document 075063-11-100, RGP6 South Hedland Rail Noise Assessment. Doc: 075063-72-100-Rev2.0-7 October 2011 Page 2

Table 1-1 Number of rakes used in noise modelling configurations Rakes PHIHP 240MTpa OHD Stage 1-4 Nelson Point Total rakes per day (loaded and unloaded) 48 Finucane Island (Goldsworthy Line) Total rakes per day (loaded and unloaded) 40.6 Western Spur Total rakes per day (loaded and unloaded) 240 MTpa Doc: 075063-72-100-Rev2.0-7 October 2011 Page 1

2. APPLICABLE REGULATIONS Rail and road noise in Western Australia is managed through the State Planning Policy 5.4 Road and Rail Transport Noise and Freight Considerations in Land Use Planning (SPP 5.4 gazetted September 2009) which was developed under the Planning and Development Act 2005 in consultation with the Department of Environment and Conservation (DEC), Main Roads WA (MRWA), Public Transport Authority (PTA) and the Western Australia Local Government Association (WALGA). The policy is only triggered by certain activities. If the expansion falls outside of the listed activities then the policy is not triggered. The following activities trigger the policy: New passenger and freight rail infrastructure projects; Major redevelopments of railways; and Minor redevelopments that are likely to adversely affect a noise-sensitive land use. The policy defines a major redevelopment of a railway as follows: A proposed substantial realignment, either inside or outside the existing corridor, or A rail duplication; or Works that significantly increase capacity. For the purposes of this policy, a minor redevelopment of a railway means minor works such as crossovers, sidings, turnouts, yards, loops, and refuges, relief lines, straightening of curves, resleepering or the installation of track signalling devices. The outdoor noise assessment criteria is given in Table 2-1 and the criteria are applicable to the emission of road and rail transport noise as received at a noise-sensitive land use. These noise levels apply at noise-sensitive receivers, at 1m from the most exposed, habitable façade of the building, at each floor level, and within at least one outdoor living area on each residential lot. When predicting transport noise levels under this policy a +2.5dB façade correction is to be applied for both road and rail as explained in section 3.1 (page 5) of the Implementation Guidelines for State Planning Policy 5.4 Road and Rail Transport Noise and Freight Considerations in Land Use Planning. Table 2-1 Outdoor noise criteria Time of day Noise Target Noise Limit Day (6am 10pm) L Aeq(Day) = 55dB(A) L Aeq(Day) = 60dB(A) Night (10pm 6am) L Aeq(Night) = 50dB(A) L Aeq(Night) = 55dB(A) The 5dB difference between the outdoor noise target and the outdoor noise limit, as prescribed in Table 2-1, represents an acceptable margin for compliance. In most situations in which either the noise-sensitive land use or the major road or railway already exists, it should be practicable to Doc: 075063-72-100-Rev2.0-7 October 2011 Page 2

achieve outdoor noise levels within this acceptable margin. In relation to Greenfield sites, however, there is an expectation that the design of the proposal will be consistent with the target ultimately being achieved. For major and minor redevelopments the noise criteria in Table 2-1 should be used as guidance. The policy recognizes that in a number of instances it may not be reasonable and practicable to meet the noise target criteria. Where transport noise is above the target level, measures are expected to be implemented that best balance reasonable and practicable considerations, such as noise cost/benefit, feasibility, community preferences, amenity impacts, safety, security and conflict with other planning and transport policies. In these cases the community should also be consulted to assist in identifying best overall solutions. 2.1 Application of State Planning Policy 5.4 to Outer Harbour Development The Western Spur rail line is defined as per the policy as a major redevelopment. For major or minor redevelopments, the noise criteria in the policy need not be applied, but instead be used as guidance. The policy does not apply to warning devices installed on road and rail vehicles. Therefore, the policy is not applicable to Locomotive horns (used at road crossings) and hence Locomotive horns have not been considered in this rail noise assessment. Doc: 075063-72-100-Rev2.0-7 October 2011 Page 3

3. NOISE MODELLING 3.1 Rail Noise Impacts Rail noise can be classified as a transient noise (i.e. a relatively short duration noise which comes and goes with time). This type of noise usually has a larger impact on communities, as normal industrial operations noise is more continuous and homogenous and as a result a certain level of tolerance and habituation occurs. By comparison, rail noise tolerance and habituation are a lot more difficult for residents to develop over time. This is especially difficult during the early morning hours when ambient noise levels are at their lowest and people are trying to sleep. 3.2 Noise Model Software An acoustic model has been developed using the SoundPlan 4 noise modelling program developed by SoundPlan LLC. The SoundPlan software calculates sound pressure levels at nominated receiver locations or produces noise contours over a defined area of interest around the noise sources. The inputs required are noise source data, ground topographical data, meteorological data and receiver locations. 3.3 Methodology Rail noise was modelled from the main line rail along the Western Spur line (south of South Hedland) to Boodarie Loop (see Figure 1-2 for model layout). Rail operations within the port facility at Finucane Island were also modelled. The rail noise model has incorporated the following assumptions: The frequency of rail movements is independent of date and time; Train speed for each track is as per current operations (i.e. maximum of 60 km/h for the rail and 20 km/h through the facility yards); Each full rake is loaded to capacity with 15480 T ore, and pulled by two locomotives; The number of empty ore car movements equals the number of fully loaded ore car movements; The model also includes rail squeal noise as the train negotiates the bends in the rail and shunting noises in the car dumper yards (noise levels 5 are based on the site measurements specific for each rail curve); and The model was calibrated based on verification measurements taken by SVT and using weather conditions as recorded by the Bureau of Meteorology in Port Hedland. The model has been shown to be accurate to 3dB. The layout of the rail model can be seen in Appendix A. 4 http://www.soundplan.com/ 5 Noise levels are based on L AEQ levels from the site field measurements for each curve. See SVT document 075063-51-100, Rail Biannual noise monitoring for Port Hedland October 2010. Doc: 075063-72-100-Rev2.0-7 October 2011 Page 4

3.3.1 Measured Noise Levels Site Field Measurements Field Measurement - Methodology As per the minimum requirements outlined in the Implementation Guidelines for the policy, sound level measurements were taken using a Brüel & Kjaer type 2260 sound level meter which meets the requirements for Type 1 sound level meters as specified in AS 1259. The meter also meets the requirements for octave band filters as specified in IEC 1260 and AS/NZS 4476:1997. The sound level meter was calibrated on site before and after measurements was taken using a Brüel & Kjaer type 4231 reference sound source. Field noise measurements were taken in accordance with Australian Standard AS2377:2002 Acoustics-Methods for the measurement of railbound vehicle noise. Field Measurements - Calculation of Sound Power Levels The sound power level of BHP Billiton Iron Ore locomotives and ore cars used in the model are based on measurements taken by SVT at the BHP Billiton Port Hedland facility in April 2009 and September 2009. Sound power levels were calculated from noise measurements taken for rail squeal, loaded/unloaded moving trains (at varying speeds), car dumper shunting and locomotive noise (at various notch settings). The sound power levels for items used in the model are presented in Table 3-1, Table 3-2 and Table 3-3. Positions referenced in these tables can be found in Appendix B. Table 3-1: Ore Car Sound Power Level Octave Band Sound Power Levels in db (lin) Position Overall 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz db(a) Loaded P3 91.7 103.5 100.5 95.7 89.3 83.4 87.1 86.7 77.5 94.4 Loaded P4 92.3 93.6 91.8 92.3 89.3 81.9 86.4 85.3 85.6 93.3 Unloaded P4 100.1 102.3 105.1 102.4 95.2 97.1 96.7 92.0 89.2 102.7 Unloaded P5 96.2 102.6 100.1 98.9 87.2 83.9 87.8 82.5 74.6 94.6 Unloaded P6 100.0 103.6 104.6 102.2 93.9 89.1 91.6 84.4 84.6 98.8 Loaded P8 98.5 102.7 108.6 101.3 99.4 91.2 90.4 88.9 86.8 100.8 Loaded Straight 85.5 88.7 87.3 93.1 80.9 72.0 77.8 70.9 62.0 86.7 Loaded P6 82.9 92.2 99.0 96.3 94.7 88.4 92.5 90.9 90.0 98.8 Loaded P7 104.9 110.0 109.3 102.4 98.6 92.9 94.6 96.7 93.3 103.3 P1 89.0 101.4 96.1 87.3 86.5 84.4 92.9 96.6 96.8 101.0 P2 91.1 106.0 91.7 83.2 81.3 78.3 86.2 88.7 82.8 92.9 Doc: 075063-72-100-Rev2.0-7 October 2011 Page 5

Position Table 3-2 Locomotive Sound Power Level Octave Band Sound Power Levels db (lin) 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Overall db(a) Loco P3 103.5 118.1 103.5 100.9 98.1 92.0 90.1 85.1 82.9 100.1 Loco P4 Unloaded 102.6 110.2 113.6 100.3 96.0 94.0 95.3 94.5 92.5 103.3 Loco P5 97.8 112.1 106.1 99.0 91.8 89.2 88.9 83.1 74.5 97.3 Loco P5 Unloaded 98.0 94.6 97.8 99.7 87.5 84.5 89.3 85.4 78.3 95.6 Loco P6 101.6 109.2 110.9 101.2 98.0 93.8 94.4 93.8 92.4 102.6 Loco P6 unloaded 100.8 115.4 105.3 102.6 92.8 90.7 91.6 84.7 77.3 99.3 Loco P8 97.6 101.6 108.6 102.0 96.2 88.4 89.0 88.3 85.9 99.5 Loco Straight 101.5 106.4 111.8 97.1 88.9 87.2 86.4 83.6 78.1 98.0 Loco P4 103.0 109.8 101.6 98.1 96.4 95.2 91.9 88.1 87.4 100.1 Position Table 3-3: Yard Sound Power Levels Octave Band Sound Power Levels db (lin) 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Overall db(a) Yard Squeal 103.0 115.9 99.9 98.6 103.7 105.9 112.2 107.5 107.3 115.8 CDShunt UL 112.6 111.3 108.9 104.7 102.4 101.3 99.7 94.2 86.0 106.4 CDShunt Loaded 90.2 90.3 91.4 89.8 93.7 95.7 96.5 92.7 83.9 101.3 Road100 Squeal 104.0 110.7 97.3 96.2 95.4 99.5 108.5 109.5 108.9 114.4 Bilo Crossing 78.1 90.0 75.5 73.6 72.7 77.8 87.4 88.7 87.9 93.5 Doc: 075063-72-100-Rev2.0-7 October 2011 Page 6

3.3.2 Rail Model Overview Within the noise model the rail line was divided and defined according to speed, radius of curvature and rail squeal potential as per Table 3-1 and Table 3-2. The NORD 2000 assessment method was used for the model calculations, based on Nordic Rail Traffic Noise Prediction Method (1984). NORD 2000 which calculates L Aeq and L max values using spectral data of the trains. It calculates absorption loss, propagation and considers the terrain and reflections. 3.3.3 Meteorological Conditions Applied The new road and rail transport policy ( Road and Rail Transport Noise and Freight Considerations in Land Use Planning ) does not specify the meteorological conditions to be used for rail noise modelling. The predicted L Aeq noise levels have been calculated using worst case meteorological conditions (as outlined in EPA Draft Guidance Note No.8. The conditions applied are as follows; Day (07:00-19:00) wind speed 4m/s; Pasquill Stability Class E ; temperature - 20 C; and relative humidity 50%. Night (19:00 07:00) wind speed 3m/s; Pasquill Stability Class F ; temperature 15 C; and relative humidity 50%. The meteorological condition for night-time includes the refraction effects of sound waves during propagation in the parts of the atmosphere close to the ground. Worst-case conditions usually occur during night-time, when downward refraction bends the waves towards the ground increasing the noise levels at the receiver. The night time meteorological conditions were used in the model as this represents the worst case conditions. 3.4 Rail Movements Table 1-1 shows the number of rakes to be transported to Nelson Point, Finucane Island and the Western Spur. Doc: 075063-72-100-Rev2.0-7 October 2011 Page 7

4. RESULTS 4.1 Noise Modelling Results The predicted received noise levels at each sensitive receiver and noise contour plots are given in Table 4-1 6 and Figure 4-1 respectively. All results include the applicable 2.5dB façade correction factor. Expansion Project Table 4-1 Rail Noise Modelling Results in South Hedland Receiver South Hedland W South Hedland S Green Acres PHIHP 32.0 33.9 30.1 Outer Harbour Development Stage 1 Outer Harbour Development Stage 2 Outer Harbour Development Stage 3 Outer Harbour Development Stage 4 32.3 34.1 30.9 32.5 34.2 31.5 32.8 34.3 32.1 33.1 34.4 32.6 As can be seen in Table 4-1 the received noise at all the receivers are below the noise target of L Aeq 50dB(A). Figure 4-1 shows noise contour map for the Western Spur line. 6 Worst case meteorological conditions have been applied. Doc: 075063-72-100-Rev2.0-7 October 2011 Page 8

Figure 4-1 Noise Contour plot showing the,goldsworthy and Western Spur and main lines. Doc: 075063-72-100-Rev2.0-7 October 2011 Page 9

APPENDIX A : RAIL NOISE MODEL LAYOUT Figure 4-2 Model screen shot showing sensitive receivers and Western Spur rail line. Doc: 075063-72-100-Rev2.0-7 October 2011 Page A-1