Method development and validation for the simultaneous estimation of ambroxol HCL and levofloxacin by using RP HPLC method

Similar documents
ISSN: Available online Journal of Global Trends in Pharmaceutical Sciences Vol.2, Issue 3, pp , July -Sept 2011

SIMULTANEOUS RP HPLC METHOD DEVELOPMENT AND VALIDATION OF LEVOFLOXACIN AND ORNIDAZOLE IN COMBINED PHARMACEUTICAL DOSAGE FORMS

Int. Res J Pharm. App Sci., 2013; 3(5): ISSN:

Literature search reveals that various analytical methods like HPTLC [1], HPLC [2,3] and Spectroscopy [3,4]

Research Article Vol: 1; Issue: 1

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

SCIENTIFIC DISCUSSION

Potential of CO 2 retrieval from IASI

Determination of Pesticide Residues in Tea: An AOAC Collaborative Study

Minisart Syringe Filters

HOSE ASSEMBLY CLEANLINESS

B 270 Superwite D Requirements deviating from these specifications must be defined in writing in a customer agreement.

Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria

Verification For Quantitative Test Methods

THINGS YOU FORGOT OR DIDN'T KNOW ABOUT EMPOWER

JULIAN DEAN, PETER IVANOV, SEAN COLLINS AND MARIA GARCIA MIRANDA

Filters for HPLC and UHPLC Columns

ACQUITY Systems with 2D Technology

filtration at its finest Thermo Scientific Nalgene Syringe Filters

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Three years ( ) measurements of atmospheric concentrations of organochlorine pesticides (OCPs) at Station Nord, North East Greenland

Hydrosulfide adducts of organo-iridium anticancer complexes

Introducing EXP. the new gold standard of extreme pressure chromatography hardware and consumables.

Airspace Complexity Measurement: An Air Traffic Control Simulation Analysis

COMPARATIVE STUDY ON GROWTH AND FINANCIAL PERFORMANCE OF JET AIRWAYS, INDIGO AIRLINES & SPICEJET AIRLINES COMPANIES IN INDIA

Comparison of the Novel ColiPlate

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

Discriminate Analysis of Synthetic Vision System Equivalent Safety Metric 4 (SVS-ESM-4)

Silica-based Solid Phase Extraction Columns

Supplemental Information

ScienceDirect. Prediction of Commercial Aircraft Price using the COC & Aircraft Design Factors

Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

Technical Report. Aircraft Overflight and Noise Analysis. Brisbane, California. December Prepared by:

CASM electric cylinders

high performance pipettors Excellence and precision for all your liquid handling procedures.

GEOGRAPHY OF GLACIERS 2

Flight Inspection for High Elevation Airports

Flow Splitter. Installation Instructions

Studies on effect of electrostatic spraying in

Quantitative Analysis of the Adapted Physical Education Employment Market in Higher Education

Proceedings of the 54th Annual Transportation Research Forum

PRAJWAL KHADGI Department of Industrial and Systems Engineering Northern Illinois University DeKalb, Illinois, USA

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

TUBING PLEASE READ. Tubing for Samplers with Peristaltic Pumps

PREFERENCES FOR NIGERIAN DOMESTIC PASSENGER AIRLINE INDUSTRY: A CONJOINT ANALYSIS

Estimating the Risk of a New Launch Vehicle Using Historical Design Element Data

According to FAA Advisory Circular 150/5060-5, Airport Capacity and Delay, the elements that affect airfield capacity include:

Environmental Performance Evaluation of Ro-Ro Passenger Ferry Transportation

TECHNICAL REPORT. Title: NIRCam Point Source SNR vs. Filter, Source Brightness and Readout Combinations

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

Authors. Courtney Slavin Graduate Research Assistant Civil and Environmental Engineering Portland State University

HOW TO IMPROVE HIGH-FREQUENCY BUS SERVICE RELIABILITY THROUGH SCHEDULING

Measuring Performance of an Automated and Miniaturized LANCE Ultra camp Assay for the G i -coupled 5-HT 1A Receptor a Comparative Study

Solid waste generation and disposal by Hotels in Coimbatore City

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

CITY OF LYNDEN STORMWATER MANAGEMENT PROGRAM REPORT MARCH 1, 2016

Individual Lab Report Ci-Trol Jun,2016. APTT (seconds) Ci-Trol 1 - Lot# Your Lab

INNOVATIVE TECHNIQUES USED IN TRAFFIC IMPACT ASSESSMENTS OF DEVELOPMENTS IN CONGESTED NETWORKS

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

D DAVID PUBLISHING. Development and Achievement of the T-50 Flight Control s Consolidated OFP. 1. Introduction. 2. Consolidated OFP s Needs

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

Analysis of vertical flight efficiency during climb and descent

The 15QQ series is a unique and versatile peristaltic pump range designed for accurate dispensing of liquids.

COLILERT - WHAT'S AL THE FUSS ABOUT? Elizabeth Hanko. Elizabeth Hanko, Senior Consultant. AWT, Victoria

UC Berkeley Working Papers

Alpha Systems AOA Classic & Ultra CALIBRATION PROCEDURES

SOURDINE II EU- 5FW project on Noise Abatement Procedures. Overall view. Ruud den Boer / Collin Beers Department: ATM & Airports

Tacta Mechanical Pipettes Perfectly Balanced

Study on Hotel Management Graduates Perceptions and Preferences of Jobs in Hotel Industry in Chennai City

A Statistical Method for Eliminating False Counts Due to Debris, Using Automated Visual Inspection for Probe Marks

Demand Shifting across Flights and Airports in a Spatial Competition Model

How long does levofloxacin take to work for pneumonia

A RECURSION EVENT-DRIVEN MODEL TO SOLVE THE SINGLE AIRPORT GROUND-HOLDING PROBLEM

Implement Change Control into Your Process Validation Program

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

A Primer on Fatigue Damage Spectrum for Accelerated and Reliability Testing

An Econometric Study of Flight Delay Causes at O Hare International Airport Nathan Daniel Boettcher, Dr. Don Thompson*

Flight inspection and validation

Interpretation Guide

3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader

American Airlines Next Top Model

Interpretation Guide

Appendix B Ultimate Airport Capacity and Delay Simulation Modeling Analysis

EUR/SAM corridor airspace concept

Controlled Cooking Test (CCT)

A Simulation Approach to Airline Cost Benefit Analysis

AMC and GM to Part-CAT Issue 2, Amendment 3

CONNECT Events: Flight Optimization

Mathcad Prime 3.0. Curriculum Guide

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

Fuel Burn Impacts of Taxi-out Delay and their Implications for Gate-hold Benefits

Portable Noise Monitor Report

Impact of Landing Fee Policy on Airlines Service Decisions, Financial Performance and Airport Congestion

CFIT-Procedure Design Considerations. Use of VNAV on Conventional. Non-Precision Approach Procedures

A stated preference survey for airport choice modeling.

Hydrological study for the operation of Aposelemis reservoir Extended abstract

Estimating Operations and Airport-Specific Landing & Take-off Cycles at GA Airports

AIRLINES decisions on route selection are, along with fleet planning and schedule development, the most important

Analysis of en-route vertical flight efficiency

AMC and GM to Part-SPO Amendment 3

Transcription:

IJPAR Vol.6 Issue 4 Oct - Dec -2017 Journal Home page: ISSN:2320-2831 Research article Open Access Method development and validation for the simultaneous estimation of ambroxol HCL and levofloxacin by using RP HPLC method B.Jyothsna *1, V.Swapna 1 1 Chilkur balaji college pharmacy, Aziznagar (v),moinabad(m)-5000075 Telangana, India *Corresponding Author: B.Jyothsna Email: b.jyothsna369@gmail.com ABSTRACT A new, simple, precise, accurate and reproducible RP-HPLC method for Simultaneous estimation of bulk and pharmaceutical formulations. Separation of Ambroxol HCL and levofloxacin was successfully achieved by Inertsil C18, 250 X4.6, 5µm or equivalent in an isocratic mode utilizing 0.1% OPA: methanol (60:40) at a flow rate of 1mL/min and eluate was monitored at 238nm, with a retention time of 2.173 and 4.344 minutes for Ambroxol HCL and levofloxacin respectively. The method was validated and there response was found to be linear in the drug concentration range of 50µg/ml to150 µg/ml for Ambroxol HCL and 50µg/ml to150 µg/ml for Levofloxacin. The values of the correlation coefficient were found to0.999for Ambroxol HCL and 1for levofloxacin respectively. The LOD and LOQ for Ambroxol HCL were found to be 0.035and 0.116 respectively. The LOD and LOQ for Levofloxacin were found to be 0.1884 and 0.6281 respectively. This method was found to be good percentage recovery for Ambroxol HCL and Levofloxacin were found to be 99.1% and 99.7% respectively indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample so, the method specifically determines the analyte in the sample without interference from excipients of tablet dosage forms. The method was extensively validated according to ICH guidelines for Linearity, Accuracy, Precision, Specificity and Robustness Keywords: Ambroxol and Levofloxacin, Validation, HPLC INTRODUCTION Analytical methods development and validation play important roles in the discovery, development, and manufacture of pharmaceuticals. The current good manufacturing practice (CGMP) and Food Drug Administration (FDA) Guidelines insist for adoption of sound methods of analysis with greater sensitivity and reproducibility. Development of a method of analysis is usually based on prior art (or) existing literature, using the same (or) quite similar instrumentation.it is rare today that an HPLC-based method is developed that does not in same way relate (or) compare to existing, literature based approaches. Today HPLC (High performance liquid chromatography) is the method of choice used by the pharmaceutical industry to assay the intact drug and degradation products. The ~717~

appropriate selection and chromatographic conditions ensure that the HPLC method will have the desired specificity. UV spectroscopy is also a simple analytical tool widely used for routine assay of drugs. Hence for the assay of the selected drugs HPLC and UV spectroscopy has been chosen for these proposed methods. The developed chromatographic methods further validated as per ICH or USFDA guidelines for all the critical parameters. To access the precision and to evaluate the results of analysis the analyst must use statistical methods. These methods include confidence limit, regression analysis to establish calibration curves. In each analysis the critical response parameters must be optimized and recognized if possible DRUG PROFILE Ambroxol Expectorants Structure Structure of Ambroxol IUPAC Name : 4-{[(2-amino-3,5- dibromophenyl)methyl]amino}cyclohexan-1-ol hydrochloride Molecular formula : C 13 H 19 Br 2 ClN 2 O Molecular Weight : 414.56376 Solubility : Soluble in methanol, water, ethanol, and DMSO. Insoluble in ether. Pka : 15.26 Mechanism of action Ambroxol is a mucolytic agent. Excessive Nitric oxide (NO) is associated with inflammatory and some other disturbances of airways function. NO enhances the activation of soluble guanylate cyclase and cgmp accumulation. Ambroxol has been shown to inhibit the NO-dependent activation of soluble guanylate cyclase. It is also possible that the inhibition of NO-dependent activation of soluble guanylate cyclase can suppress the excessive mucus secretion, therefore it lowers the phlegm viscosity and improves the mucociliary transport of bronchial secretions. Levofloxacin Quinolones ~718~

Structure Stucture of Levofloxacin IUPACNAME (2S)-7-fluoro-2-methyl-6-(4-methylpiperazin-1-yl)- 10-oxo-4-oxa-1-azatricyclo[7.3.1.0⁵,¹³]trideca- 5(13),6,8,11-tetraene-11-carboxylic acid Molecular formula C 18 H 20 FN 3 O 4 Molecular Weight 361.3 Solubility Soluble in water PKA 5.45 Mechanism of action Levofloxacin inhibits bacterial type II topoisomerases, topoisomerase IV and DNA gyrase. Levofloxacin, like other fluoroquinolones, inhibits the A subunits of DNA gyrase, two subunits encoded by the gyra gene. This results in strand breakage on a bacterial chromosome, supercoiling, and resealing; DNA replication and transcription is inhibited. MATERIALS AND METHODS Equipment and Apparatus used Electronic balance HPLC Waters Separation Module LC- 20AT Prominence Liquid Chromatography UV Detector Chromatographic data Software : EMPOWER SymmetryColumn C18 (250 X 4.6cm, Id- 5µ) Vacuum filter pump Mobile phase reservoir Ultra Sonicator, Membrane filter(0.45 and 0.2 microns) Reagents Acetonitrile HPLC grade Water (HPLC) Potassium Dihydrogen Phosphat METHOD VALIDATION System suitability Tailing factor for the peaks due to Ambroxol and Levofloxacin in standard solution should not be more than 2.0.Theoretical plates for the Ambroxol and Levofloxacin peaks in standard solution should not be less than 2000. Specificity Solution of standard, sample, blank and placebo were prepared as per test procedure and injected into the HPLC system. Acceptance criteria Chromatogram of standard and sample should be identical with near Retention time. Blank interference A study to establish the interference of blank was conducted. Diluent was injected into HPLC system as per the test procedure. Acceptance criteria Chromatogram of blank should not show any peak at the retention time of analyte peak. There is no interference due to blank at the retention time of analyte. Hence the method is specific. Linearity Prepare a series of standard solutions and inject into HPLC system. Plot the graph of standard ~719~

versus the actual concentration in µg/ml and determine the coefficient of correlation and basis for 100% response. Acceptance criteria Linearity regression coefficient of average peak area response of replicate injections plotted against respective concentration should not be less than 0.999. The % y-intercept as obtained from the linearity data (without extrapolation through origin 0, 0) should be within ±2.0. Statistical evaluation A graph between the concentration and the average area was plotted. Points for linearity were observed. Using the method of least squares, a line of best fit was taken and the correlation Coefficient, slope and, y-intercept were calculated. PRECISION Preparation of sample Transfer the 1044.5mg of sample into a 100ml of volume at flask and add 10ml of water and 10ml of Methanol and sonicate 20min and makeup with water. Transfer the above solution into 2ml into 100ml volume metric flask dilute to the volume with water. The method precision parameters were evaluated from sample chromatograms obtained, by calculating the % RSD of peek areas from 6 replicate injection. Acceptance criteria The injection reproducibility requirements are met if the %RSD for peak areas is not more than 2.0 and for retention times is not more than 2.0. Recovery/accuracy Recovery study can be performed in the concentration range of 80% to 120% of the target concentration of the test. Minimum 3 concentrations are recommended. Acceptance criteria The average percentage recovery was between 98-102% and Relative standard deviation of these recovery concentrations was less than 2%. Limit of detection The sensitivity of measurement of Ambroxol and Levofloxacin by use of proposed method was estimated in terms of the limit of detection (LOD). The LOD was calculated by the use of signal to noise ratio. In order to estimate the LOD value, the blank sample was injected six times and peak area of this blank was calculated as noice level. The LOD was calculated as three times the noise level. LOD= 3.3 σ / S Where, σ = standard deviation of intercepts of calibration curves S = mean of slopes of the calibration curves The slope S may be estimated from the calibration curve of the analyte. Limit of quantitation The sensitivity of measurement of Ambroxol and Levofloxacin by the use of proposed method was estimated in terms of limit of quantitation (LOQ). The LOQ was calculated by the use of signal to noise ratio. In order to estimate the LOQ value, the blank sample was injected six times and the peak area of this blank was calculated at noise level. The LOQ was calculated as ten times the noise value gave the LOQ. LOQ = 10 σ / S Where, σ = standard deviation of intercepts of calibration curves S = mean of slopes of the calibration curves The slope S may be estimated from the calibration curve of the analyte. ROBUSTNESS Effect of variation in flow rate Prepare the system suitability solution as per the test method and inject into the HPLC system with ±0.2 ml of the method flow. Evaluate the system suitability values as required by the test method for both flow rates. Actual flow rate was 1.0 ml/min and it was changed to 0.8ml/min and 1.2ml/min and inject into HPLC and system suitability was checked. Effect of variation in wavelength Prepare the system suitability solution as per the test method and injected into the HPLC with ~720~

AU 2.173 4.344 ±2nm variation in wavelength. Evaluate the system suitability values as required by the test method for both wavelengths Optimized method Mobile Phase : 0.1%OPA: Methanol (60:40) Column : Inertsil C8, 250X4.6, 5um Flow rate : 1.0ml /min Temperature : 30 0 C Injection Volume : 10ul Detector : PDA Procedure Inject 10μL of standard, sample into chromatographic system and measure the areas for the Ambroxol and Levofloxacin peaks and calculate the % assay by using the formula 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes Chromatogram for optimized method Name Retention Time Area USP Resolution USP Tailing USP Plate Count Ambroxol 2.173 1334998 1.58 3841 Levofloxacin 4.344 2350999 12.42 1.36 7552 Observation RT was found to be good and the peak symmetry of both drugs were good. And the resolution theoretical plate count and tailing were within the limits and it is used for validation of the method. Preparation of mobile phase Transfer 500ml of HPLC water into 500ml of beaker add 0.1%OPA. Transfer the above solution 600ml of 0.1%OPA, 400ml of Methanol is used as mobile phase. They are mixed and sonicated for 20min. Preparation of the ambroxol and levofloxacin standard and sample solution Preparation of standard solution Accurately weigh and transfer 75mg Ambroxol and 500mg Levofloxacin into 100ml of volumetric flask and add 10ml of Methanol and sonicate 10min (or) shake 5min and make with water. Transfers the above solution into 2ml into 100ml volumetric flask dilute to volume with water. Preparation of sample stock solution Commercially available 20 tablets ware weighed and powdered the powdered equivalent to the 1044.5mg of Ambroxol and Levofloxacin of active ingredients were transfer into a 100ml of volumetric flask and add 10ml of Methanol and sonicate 20min (or) shake 10min and makeup with water. Transfers above solution 2ml into 100ml of the volumetric flask dilute the volume with Methanol. And the solution was filtered through 0.45μm filter before injecting into HPLC system. Uv spectroscopy wavelength determination The UV spectrums of Ambroxol and Levofloxacin under these mobile phase conditions were shown below and from these spectrums, Lambda Max 238 nm were observed. ~721~

AU 1.677 AU AU 0.60 0.40 2.173 Peak 1 212.0 0.20 0.00 4.343 Peak 2 0.30 245.0 291.3 0.20 0.10 0.00 220.00 240.00 260.00 280.00 300.00 320.00 340.00 360.00 380.00 400.00 nm Fig 5: Uv spectrum of standard Ambroxol and Levofloxacin Peak Method development trails Trail 1 Mobile Phase: 0.1%OPA: Methanol (60:40) Column: Phenomenex C18, 150X4.6, 5um Flow rate: 1.0ml /min Temperature: 30 0 C Injection Volume: 10ul Detector: PDA 3.00 2.50 2.00 1.50 1.00 0.50 0.00 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 Minutes Name Retention Time Area USP Resolution USP Tailing USP Plate Count Ambroxol 1.677 10643613 2.44 5831 Typical chromatogram of trail 1 Observation: second peak was not detected & tailing was observed Reason: may be concentration Corrective Action: Change the concentration Trail 2 Mobile Phase: 0.1%OPA: Methanol (60:40) Column: Phenomenex C18, 150X4.6, 5um Flow rate: 1.0ml/min Temperature: 30 0 C Injection Volume: 10ul Detector: PDA ~722~

AU 1.657 2.274 AU 1.669 2.287 0.40 0.30 0.20 0.10 0.00 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 Minutes Name Retention Time Area USP Resolution USP Tailing USP Plate Count Ambroxol 1.669 566860 2.11 6043 Levofloxacin 2.287 2934510 4.57 1.91 2949 Typical chromatogram of trail 2 Observation: we got two peaks but tailing was failed Reason: may be due to injection volume Corrective Action: Change injection volume Trail 3 Mobile Phase: 0.1%OPA: Methanol (60:40) Column: Phenomenex C18, 150X4.6, 5um Flow rate: 1.0ml/min Temperature: 30 0 C Injection Volume: 8 ul Detector: PDA 0.30 0.20 0.10 0.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 Minutes Name Retention Time Area USP Resolution USP Tailing USP Plate Count Ambroxol 1.657 482769 1.99 7309 Levofloxacin 2.274 2299518 4.83 1.79 3070 Typical chromatogram of trail 3 Observation: we got two peaks but tailing was low Reason: may be due to column Corrective Action: Change the column Trail 4 Mobile Phase: 0.1%OPA: Methanol (60:40) Column: Inertsil C8, 250X4.6, 5um Flow rate: 1.0ml /min Temperature: 30 0 C Injection Volume: 10ul Detector: PDA ~723~

AU 2.173 4.344 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes Name Retention Time Area USP Resolution USP Tailing USP Plate Count Ambroxol 2.173 1334998 1.58 3841 Levofloxacin 4.344 2350999 12.42 1.36 7552 Typical chromatogram of trail 9 Observation RT was found to be good and the peak symmetry of both drugs were good. And the resolution theoretical plate count and tailing were within the limits and it is used for validation of the method. RESULTS AND DISCUSSIONS System suitability System suitability data of Ambroxol and Levofloxacin parameter Ambroxol Levofloxacin Acceptance criteria Retention time 2.171 4.342 +-10 Theoretical plates 3815 7547 >2500 Tailing factor 1.59 1.35 <2.00 % RSD 0.2 0.5 <2.00 Standard Results of Ambroxol S.no Sampl name RT Area USP plate count USP tailing 1. Injection1 2.169 1341010 3848 1.57 2. Injection 2 2.170 1342391 3858 1.58 3. Injection 3 2.176 1342732 3804 1.56 4. Injection 4 2.175 1337571 3840 1.56 5. Injection 5 2.175 1341222 3855 1.57 Standard Results of Levofloxacin S.no Sample name RT Area USP plate count USP tailing 1. Injection 1 4.334 2341300 7701 1.36 2. Injection 2 4.347 2361615 7565 1.37 3. Injection 3 4.353 2350663 7658 1.37 4. Injection 4 4.355 2337632 7751 1.36 5. Injection 5 4.342 2336473 7760 1.38 ~724~

RESULT Results of system suitability study are summarized in the above table. Six consecutive injections of the standard solution showed uniform retention time, theoretical plate count, tailing factor and resolution for both the drugs which indicate a good system for analysis. Specificity Specificity data for Ambroxol and Levofloxacin S no Sample name Ambroxol area Rt Levofloxacin Area Rt 1 Standard 1341010 2.169 2341300 4.334 2 Sample 1351169 2.171 2349438 4.342 3 Blank - - - - 4 Placebo - - - - Accuracy Accuracy data for Ambroxol S.NO Accuracy Injecton Sample area RT level 1 670989 2.172 1 50% 2 670987 2.178 2 100% 3 150% 3 670544 2.174 1 1348025 2.175 2 1343803 2.174 3 1344430 2.179 1 2016609 2.175 2 2013780 2.177 3 2016871 2.175 ~725~

S.NO 1 50% Accuracy level 2 100% 3 150% Accuracy (%recovery) results of Ambroxol Sample Sample μg/ml μg/ml % Recovery % Mean name weight added found 1 522.25 7.425 7.44 100 2 522.25 7.425 7.44 100 100 3 522.25 7.425 7.43 100 1 1044.50 14.850 14.94 101 2 1044.50 14.850 14.90 100 3 1044.50 14.850 14.90 100 100 1 1566.75 22.275 22.35 100 2 1566.75 22.275 22.32 100 3 1566.75 22.275 22.36 100 100 S.NO 1 50% Accuracy level Accuracy data for Levofloxacin Injecton Sample area RT 1 1172024 4.364 2 1178580 4.361 3 1175503 4.362 1 2344198 4.358 2 100% 3 150% 2 2347708 4.363 3 2343797 4.362 1 3520171 4.360 2 3518383 4.364 3 3530859 4.361 S.NO 1 50% Accuracy level 2 100% 3 150% Accuracy (%recovery) results of Levofloxacin Sample Sample μg/ml μg/ml % name weight added found Recovery 1 522.25 50.000 49.82 100 2 522.25 50.000 50.10 100 3 522.25 50.000 49.97 100 1 1044.50 100.000 99.64 100 2 1044.50 100.000 99.79 100 3 1044.50 100.000 99.63 100 1 1566.75 150.000 149.63 100 2 1566.75 150.000 149.55 100 3 1566.75 150.000 150.08 100 % Mean 100 100 100 ~726~

Typical chromatogram for Accuracy 50 % Typical chromatogram for Accuracy 100 % Typical chromatogram for Accuracy 150 % ~727~

RESULT Results of accuracy study are presented in the above table. The measured value was obtained by recovery test. Spiked amount of both the drug were compared against the recovery amount. % Recovery was 100.00% for Ambroxol and 100.00% for Levofloxacin. All the results indicate that the method is highly accurate. LINEARITY Linearity data for Ambroxol S.no Conc(μg/ml) RT Area 1. 50 2.171 670568 2. 75 2.172 1008020 3. 100 2.176 1340857 4. 125 2.178 1672035 5. 150 2.176 2015934 Correlation coefficient (r 2 ) 0.999 Area, 75, 1008020 Area, 50, 670568 Area, 100, 1340857 Area, 150, 2015934 y = 43363x R² = 0.999 Area, 125, 1672035 Area Linear (Area) Linearity plot of Ambroxol Linearity data for Levofloxacin S.no Conc(μg/ml) RT Area 1. 50 4.360 1125262 2. 75 4.359 1750061 3. 100 4.363 2342288 4. 125 4.373 2933934 5. 150 4.363 3510301 Correlation coefficient (r 2 ) 0.999 ~728~

Area, 150, 3510301 Area, 125, 2933934 Area, 100, 2342288 Area, 75, 1750061 y = 23378x R² = 0.9994 Area Linear (Area) Area, 50, 1125262 Lineariity plot of Levofloxacin RESULT A linear relationship between peak areas versus concentrations was observed for Ambroxol and Levofloxacin in the range of 50% to 150% of nominal concentration. Correlation coefficient was 0.999 for both Ambroxol and Levofloxacin which prove that the method is linear in the range of 50% to 150 Precision Precision data for Ambroxol S.no RT Area %Assay injection1 2.174 1345018 99 injection2 2.176 1341662 99 injection3 2.177 1347766 100 injection4 2.175 1344750 99 injection5 2.177 1347036 100 injection6 2.176 1342685 99 Mean 99 Std. Dev. 0.18 % RSD 0.18 Precision data for Levofloxacin S.no RT Area %Assay injection1 4.360 2344232 100 injection 2 4.359 2348002 100 injection 3 4.362 2342121 100 injection 4 4.358 2341546 100 injection 5 4.358 2347734 100 injection 6 4.365 2347075 100 Mean 100 Std. Dev. 0.12 %RSD 0.12 ~729~

RESULT Results of variability were summarized in the above table. % RSD of peak areas was calculated for various run. Percentage relative standard deviation (%RSD) was found to be less than 2% which proves that method is precise Limit of detction Minimum concentration of standard component in which the peak of the standard gets merged with noise called the LOD LOD = 3.3* σ/s Where; σ = standard deviation S = slope LOD for Ambroxol = 0.035 LOD for Levofloxacin =0.1884 LOD data for Ambroxol and Levofloxacin S.no Sample name RT Area 1 Ambroxol 2.178 226664 2 Levofloxacin 4.368 410697 Chromatrogram for LOD Limit of quantification Minimum concentration of standard component in which the peak of the standard gets detected and quantification LOQ = 10*σ/S Where; σ = standard deviation S = slope LOQ for Ambroxol =0.116 LOQ for Levofloxacin =0.6281 LOQ data for Ambroxol and Levofloxacin S.no Sample name RT Area 1 Ambroxol 2.173 351847 2 Levofloxacin 4.358 606845 ~730~

Chromatogram for LOQ CONCLUSION The study is focused to develop and validate HPLC methods for estimation of Ambroxol and Levofloxacin in tablet dosage form. For routine analytical purpose it is desirable to establish methods capable of analyzing huge number of samples in a short time period with good robustness, accuracy and precision without any prior separation steps. HPLC method generates large amount of quality data, which serve as highly powerful and convenient analytical tool. The method shows good reproducibility and good recovery. From the specificity studies, it was found that the developed methods were specific for Ambroxol and Levofloxacin. REFERENCES [1]. Sharma BK. Instrumental methods of chemical analysis, Introduction to Analytical chemistry, 23thed.Goel Publishing House Meerut, 2004, P12-23. [2]. H.H. Willard, L.L. Merritt, J.A. Dean, F.A. Settle. Instrumental Methods of Analysis, 7th edition, CBS publishers and Distributors, New Delhi. 1986, 518-521, 580-610. [3]. John Adamovies. Chromatographic Analysis of Pharmaceutical, Marcel Dekker Inc. New York, 2, 74, 5-15. [4]. GurdeepChatwal, Sahm K. Anand. Instrumental methods of Chemical Analysis, Himalaya publishing house, New Delhi, 5, 2002, 1.1-1.8, 2.566-2.570 [5]. D. A. Skoog. J. Holler, T.A. Nieman. Principle of Instrumental Analysis, 5th edition, Saunders College Publishing, 1998, 778-787. [6]. Skoog, Holler, Nieman. Principals of Instrumental Analysis, Harcourt Publishers International Company, 5, 2001, 543-554. [7]. William Kemp. Organic Spectroscopy, Palgrave, New York, 2005, 7-10, 328-330 [8]. P.D. Sethi. HPLC: Quantitative Analysis Pharmaceutical Formulations, CBS Publishers and distributors, New Delhi (India), 2001, 3-137 [9]. Method validation guidelines International Conference on harmonization; GENEVA; 1996 [10]. Berry RI, Nash AR. Pharmaceutical Process Validation, Analytical method validation, Marcel Dekker Inc. New http//en.wikipedia.org/wiki/chromatography. [11]. Ambroxol Drug profile: www.drugbank.ca/drugs/db06742. [12]. Levofloxacin Drug profile.www.drugbank.ca/drugs/db01137. [13]. Shivani Chanda et al.; Development And Validation Of Spectrophotometric Method For Of Levofloxacin Hemihydrate And Ambroxol Hydrochloride In Their Combined Dosage Form, IJPRBS, 2(4), 2013, 311-32 ~731~

[14]. Makarand Avhad et al.; Development And Validation Of Simultaneous Uv Spectrophotometric Method For The Determination Of Levofloxacin And Ambroxol In Tablets, International Journal of ChemTech Research, 1(4), 873-888 [15]. Belal FF et al.; Micellar liquid chromatographic method for the simultaneous determination of Levofloxacin and Ambroxol in combined tablets: Application to biological fluids, Chemistry Central Journal 7(162), 1993, 57, 411-28 ~732~