FG7M1-0,6/1 kv FG7OM1-0,6/1 kv

Similar documents
FG7R-0,6/1 kv FG7OR-0,6/1 kv

FG7OH2R-0,6/1 kv. Low voltage - Energy, signalling and control

ELECTRICAL PROPERTIES PVC FILLER NOMINAL VOLTAGE 0,6/1 kv CLOURS CORES CLOURS

FIBER OPTIC CLOSURES

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

expressfix Cable Tie Solutions Roller Ball Cable Ties Buckle Lock Cable Ties Ladder Style Cable Ties Application Tooling Protective Channel Sleeving

CW1308 Internal Telephone Cable HFFR or PVC Sheath

ANACONDA SEALTITE CONDUIT TYPE NMFG BLUE

Flexible Conduit & FittingsV 1.1

NORMACLAMP Hose Clamps

Molded High-Voltage Bushing Wells

CEELOK FAS-T CONNECTORS

SAFEPLAST HOSE PROTECTORS for full hose and personal protection SAFEPLAST always a safe choice!

PRODUCT SPECIFICATION

RTA flexible conduits

CABLE GRIPS CABLE GRIPS

inside diameter wire part no. color length I.D. after recovery gauge red Single Wall Polyolefin 2:1 Shrink Tube - Flexible

Heavy Duty Suction Hose

After wrapping the object to be tied, insert the free end of the tie through the buckle and into the tool.

CONNECTORS FROM THE GREAVES ADAP T ER Z O N E

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Captrad Cable Systems. grp cable systems

Fish Tapes. Length marked! Now laser etched in 12 increments to provide instant conduit length. n Industry leading durability

Specifications. According to CEC Rule Please Note

Smallest Connector with Removable Contacts

SFC /SFCS

Cutting and stripping tools

Ground Clamps Cable Tray

Dax Loose Tube Armored Multi-tube design Fiber cable

After wrapping the object to be tied, insert the free end of the tie through the buckle and into the tool.

FLEXIBLE STAINLESS STEEL CONNECTION HOSES

NK Multi-stage submersible pumps

General-Use Auto-Tuning HPX-T Series

CUSTOM HOSE FABRICATION

AXICOM COMPOSITE HOLLOW CORE INSULATORS STANDARD TYPES

European Technical Assessment ETA-15/0677 of 29/10/2015

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

Insulated Scissors. Handles made with shock-proof plastic. Length Blade Std. Part No. Type mm shape Pk.

Cabling solutions at the core of complex Airport projects

Data Sheet for Precision Potentiometer

Don't Guess...SPIKE it! SPIKE Tool Inc.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Realax hoses & tubes specification. Fitted for the purpose

I r o n m a n T o o l s

Industrial Fluid Systems

Trapped Key Transfer System SHGV SVM SVE

B 270 Superwite D Requirements deviating from these specifications must be defined in writing in a customer agreement.

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants

Supertrack 2. A versatile 3-circuit lighting track system, with a full range of power feeds, connectors, couplers and suspensions.

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

T O O L S F O R P R O F E S S I O N A L S ELECTROTECHNICAL PRODUCTS.

FERRULES & TOOLS Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

Knives, Cutters & Scrapers

2004 Spa Pre-Delivery Guide

CABLE CUTTING, STRIPPING AND CRIMPING TOOLS

Application A liquidtight fitting to secure flexible cord or power cable to a box or enclosure and provide strain relief. Standard Material/Finish

Hoses and Accessories PTFE Hoses. Contents. Introduction

Safety Interlock Switches

AUTO AFTERMARKET HAND PROTECTION SOLUTIONS

Electric System Serving Pierce County Current system and future investments

Home Improvement Fittings Wardrobe Fittings

Sale ends September 30 th, Store hours 7:30-4:30 M-F

Vikram & Co.

FLEXIBLE HOSES AND CONNECTIONS

PN-3, PN-4 Powernode Enclosures

Data Sheet for Precision Potentiometer

Metal Clad Cable, Armored Cable and Flexible Metal Conduit Fittings

Cover, 1 Gang; Malleable Iron; Zinc Electroplated Dichromate Aluminum Polymer Enamel; Box Mounting; Appleton[R] Brand; FS Model; With Square Handle

GRAVITY ROLLER COASTER LAUNCH COASTER

PRD486WDHU 48-INCH DUAL-FUEL PRO HARMONY RANGE WITH GRIDDLE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE RANGETOP

Installation instruction

Installation Instructions

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

SHIV Green Energy : SPECIALIST FOR :

Sliplining of Lock-Bar Steel Water Mains, Wilmington Delaware

HAND TOOLS. Combination Wrenches 120/1. Combination Wrench Sets 120/1CB. Adjustable Wrenches 250/1. Hexagon Wrenches 230/3SL.

This document is a preview generated by EVS

HPX-ET Series. Gang-Mounted Remote Cluster

Installation Instructions

Primary Cable. Wire and Cable. XX = Color Coded Description, 00 = Units of Measurement, Call for Current Pricing

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

Fish Tapes & Conduit Tools

The Olex Range. Mining Cables (flexible) to 33kV. Low Voltage Power and Control Cables

Splice Trays A LANscape Solutions Product

FIBRE MANAGEMENT AT PCB LEVEL

Installation instruction

Reliability Data LUXEON K2. Introduction. Index. Reliability Datasheet RD06

HARVIA IRON STOVE Instructions for installation and use

Metal & Teflon Lined Hose

Pole Line Hardware. Catalog

REPORT EPO-CHEM RS 500P SOLVENT-FREE, WET & RUST TOLERANT SYSTEM

SPECIAL FEATURE of OSHA Safety Lock Tag Padlock :

Premium Cutters for Plastic Gate

OW LEE CASUAL FIRESIDE Q&A

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

Blue Series Hot Melt Hose with RediFlext II Hanger System

OW LEE CASUAL FIRESIDE Q&A

Installation instruction

SUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP

Transcription:

Low voltage - Energy, signalling and control FG7M1-0,6/1 kv FG7OM1-0,6/1 kv Structure and, physical, mechanical requirements: CEI 20-13 CEI 20-38 p.q.a. CEI UNEL 35382 CEI UNEL 35384 Fire propagion: EN 60332-3-24 (CEI 20-22 III) Flame propagion: EN 60332-1-2 Corrosive gases or halogens: EN 50267-2-1 EN 50267-2-2 Smoke density (trasmittance): EN 61034-2 Toxicity index (nional standard): CEI 20-37/4-0 Low Voltage Directive: RoHS Directive: 2014/35/UE 2011/65/UE www.lrivenetacavi.com

Description Conductor: class 5, flexible, plain copper wire Insulion: rubber compound, G7 quality Filler: LS0H thermoplastic, penetring between the cores (only in multi-core s) Sheh: LS0H thermoplastic, M1 quality Colour: green or grey LS0H = Low Smoke Zero Halogen Functional characteristics Red voltage Uo/U: 0,6/1 kv opering temperure: 90 C Min. opering temperure: -15 C (without mechanical shocks) short circuit temperure: 250 C Installion conditions Minimum installion temperure: 0 C Recommended minimum bending radius: 4 times the diameter Recommended maximum tensile stress: 50 N/mm² of the cross-section of the copper Special feures Good to grease and mineral oils. Good flexibility and behaviour low temperures. Use and installion method Suitable for transport of power and transmission of signals and controls in places risk of fire and containing large number of people like schools, offices, theres, subways, hospitals, place of worship, malls and places of entertainment. For stic use indoor even in wet environments and outdoor. Can be laid on brickwork, metal structures, gangways, pipes, ducts or similar closed systems. llowed for underground laying also unprotected. N.B. For applicions not covered by Regulion EU 305/2011. Colours of the cores SINGLE-CORE TWO-CORE THREE-CORE or FOUR-CORE or FIVE-CORE or The cores in multiple s for signal and control are black, numbered, with or without GREEN/YELLOW Marking L TRIVENET CVI FG7(O)M1-0,6/1 kv [form.] IEMMEQU CEI 20-22 III CT. C [year] [traceability] [metric]

Single-core buried 1 x 10 4,0 0,7 1,4 9,4 1,91 135 80 66 73 68 64 59 1 x 16 5,0 0,7 1,4 10,4 1,21 190 107 88 96 89 83 77 1 x 25 6,2 0,9 1,4 12,2 0,780 280 141 117 124 115 108 100 1 x 35 7,4 0,9 1,4 13,6 0,554 380 176 144 150 139 131 121 1 x 50 8,9 1,0 1,4 15,4 0,386 515 216 175 186 173 162 150 1 x 70 10,5 1,1 1,4 17,3 0,272 710 279 222 229 212 199 184 1 x 95 12,2 1,1 1,5 19,4 0,206 910 342 269 270 250 234 217 1 x 120 13,8 1,2 1,5 21,4 0,161 1150 400 312 312 289 271 251 1 x 150 15,4 1,4 1,6 23,8 0,129 1425 464 355 356 330 310 287 1 x 185 16,9 1,6 1,6 26,0 0,106 1730 533 417 401 371 343 323 1 x 240 19,5 1,7 1,7 29,2 0,0801 2260 634 490 471 436 409 379 1 x 300 22,0 1,8 1,8 32,0 0,0641 2780 736-533 493 463 429 1 x 400* 26,5 2,0 1,9 36,5 0,0486 3690 868-621 575 540 500 1 x 500* 28,5 2,2 2,1 37,1 0,0384 4870 998-705 650 610 560 1 x 630* 33,0 2,4 2,3 42,2 0,0287 6340 1151-823 762 716 663 * Cable type is not certified IMQ Standards - laying depth of 0,8 m for buried s

Two-core buried 2 x 1,5 1,5 0,7 1,8 12,0 13,3 125 26 22 28 26 25 23 2 x 2,5 2,0 0,7 1,8 13,0 7,98 150 36 30 37 35 32 30 2 x 4 2,5 0,7 1,8 14,2 4,95 180 49 40 48 45 41 39 2 x 6 3,0 0,7 1,8 15,4 3,30 230 63 51 60 56 52 49 2 x 10 4,0 0,7 1,8 17,3 1,91 335 86 69 80 76 70 66 2 x 16 5,0 0,7 1,8 19,4 1,21 510 115 91 105 99 91 86 2 x 25 6,2 0,9 1,8 23,0 0,780 760 149 119 135 128 118 111 2 x 35 7,4 0,9 1,8 25,7 0,554 1010 185 140 166 156 144 136 2 x 50 8,9 1,0 1,8 29,3 0,386 1440 225 175 205 193 178 168 2 x 70 10,5 1,1 1,8 33,1 0,272 1980 289 221 252 238 219 207 2 x 95 12,2 1,1 2,0 37,4 0,206 2700 352 265 299 282 260 245 2 x 120 13,8 1,2 2,1 41,5 0,161 3350 410 305 346 327 301 284 2 x 150 15,4 1,4 2,2 46,1 0,129 4100 473 334 395 373 343 324 - two-phase circuit - laying depth of 0,8 m for buried s

Three-core buried 3 x 1,5 1,5 0,7 1,8 12,5 13,3 140 23 19 23 22 20 19 3 x 2,5 2,0 0,7 1,8 13,6 7,98 175 32 26 30 29 27 25 3 x 4 2,5 0,7 1,8 14,9 4,95 215 42 35 39 37 34 32 3 x 6 3,0 0,7 1,8 16,2 3,30 280 54 44 50 47 43 41 3 x 10 4,0 0,7 1,8 18,2 1,91 422 75 60 67 63 58 55 3 x 16 5,0 0,7 1,8 20,6 1,21 640 100 80 88 83 76 72 3 x 25 6,2 0,9 1,8 24,5 0,780 950 127 105 113 107 99 93 3 x 35 7,4 0,9 1,8 27,3 0,554 1345 158 128 139 131 121 114 3 x 50 8,9 1,0 1,8 31,2 0,386 1860 192 154 172 162 149 141 3 x 70 10,5 1,1 1,9 35,6 0,272 2570 246 194 212 200 184 174 3 x 95 12,2 1,1 2,0 40,0 0,206 3265 298 233 251 237 218 206 3 x 120 13,8 1,2 2,1 44,4 0,161 4180 346 268 290 274 252 238 3 x 150 15,4 1,4 2,3 49,5 0,129 5120 399 300 332 313 288 272 3 x 185 16,9 1,6 2,4 55,2 0,106 6335 456 340 373 352 324 306 3 x 240 19,5 1,7 2,6 61,9 0,0801 8240 538 398 439 414 382 360 3 x 300 22,0 1,8 2,8 68,0 0,0641 10700 621 455 - - - - - laying depth of 0,8 m for buried s

Four-core buried 4 x 1,5 1,5 0,7 1,8 13,4 13,3 185 23 19 23 22 20 19 4 x 2,5 2,0 0,7 1,8 14,6 7,98 210 32 26 30 29 27 25 4 x 4 2,5 0,7 1,8 16,0 4,95 260 42 35 39 37 34 32 4 x 6 3,0 0,7 1,8 17,5 3,30 350 54 44 50 47 43 41 4 x 10 4,0 0,7 1,8 19,8 1,91 530 75 60 67 63 58 55 4 x 16 5,0 0,7 1,8 22,4 1,21 840 100 80 88 83 76 72 4 x 25 6,2 0,9 1,8 26,8 0,780 1200 127 105 113 107 99 93 3x35+25 7,4/6,2 0,9/0,9 1,8 29,2 0,554/0,780 1575 158 128 139 131 121 114 3x50+25 8,9/6,2 1,0/0,9 1,8 32,4 0,386/0,780 2020 192 154 172 162 149 141 3x70+35 10,5/7,4 1,1/0,9 1,9 37,0 0,272/0,554 2820 246 194 212 200 184 174 3x95+50 12,2/8,9 1,1/1,0 2,1 42,0 0,206/0,386 3680 298 233 251 237 218 206 3x120+70 13,8/10,5 1,2/1,1 2,2 46,9 0,161/0,272 4770 346 268 290 274 252 238 3x150+95 15,4/12,2 1,4/1,1 2,4 52,5 0,129/0,206 5910 399 300 332 313 288 272 3x185+95 16,9/12,2 1,6/1,1 2,5 57,3 0,106/0,206 7080 456 340 373 352 324 306 3x240+150 19,5/15,4 1,7/1,4 2,7 65,5 0,0801/0,129 9530 538 398 439 414 382 360 3x300+150 22,0/15,4 1,8/1,4 2,9 70,8 0,0641/0,129 11370 621 455 - - - - - laying depth of 0,8 m for buried s Five-core buried 5G1,5 1,5 0,7 1,8 14,4 13,3 195 23 19 23 22 20 19 5G2,5 2,0 0,7 1,8 15,6 7,98 245 32 26 30 29 27 25 5G4 2,5 0,7 1,8 17,3 4,95 315 42 35 39 37 34 32 5G6 3,0 0,7 1,8 18,9 3,30 420 54 44 50 47 43 41 5G10 4,0 0,7 1,8 21,5 1,91 700 75 60 67 63 58 55 5G16 5,0 0,7 1,8 24,4 1,21 985 100 80 88 83 76 72 5G25 6,2 0,9 1,8 29,3 0,780 1495 127 105 113 107 99 93 5G35 7,4 0,9 1,8 32,8 0,554 2000 158 128 139 131 121 114 5G50 8,9 1,0 2,0 38,2 0,386 2890 192 154 172 162 149 141 - laying depth of 0,8 m for buried s

Multi-core / signalling and control (*) buried K = 1 K = 1,5 7G1,5 1,5 0,7 1,8 15,4 13,3 230 13 11,5 18,5 16 10G1,5 1,5 0,7 1,8 18,7 13,4 335 13 11,5 18,5 16 12G1,5 1,5 0,7 1,8 19,3 13,4 380 11 9,5 14,5 12,5 16G1,5 1,5 0,7 1,8 21,1 13,4 465 11 9,5 14,5 12,5 19G1,5 1,5 0,7 1,8 22,1 13,4 520 9 8 13 11,5 24G1,5 1,5 0,7 1,8 25,4 13,5 590 9 8 13 11,5 7G2,5 2,0 0,7 1,8 16,8 7,98 320 17,5 15,5 24 21 10G2,5 2,0 0,7 1,8 20,6 8,06 460 17,5 15,5 24 21 12G2,5 2,0 0,7 1,8 21,3 8,06 520 13,5 12 20 17,5 16G2,5 2,0 0,7 1,8 23,3 8,06 650 13,5 12 20 17,5 19G2,5 2,0 0,7 1,8 24,5 8,06 700 12 10,5 16 14 24G2,5 2,0 0,7 1,8 28,3 8,10 855 12 10,5 16 14 (*) also available without the green/yellow - all s are charged (except for the green/yellow). - laying depth of 0,8 m for buried s