ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Similar documents
INSTALLATION MANUAL AND OPERATING INSTRUCTIONS. MD25-( ) Series Airspeed Indicator

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Smallest Connector with Removable Contacts

AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators

Model Number Structure

Safety Interlock Switches

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Test Report: HEP

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Capacity 24 bottles Six shelves cradle bottles horizontally to keep corks moist o Shelves are coated to reduce vibration

DUWC1441 Designer. cabinet, and black interior.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

SPEDESTER Series QUICK REFERENCE GUIDE

SafeSite. Series LED Based Signaling for Hazardous Locations

REFRIGERATION. Standard Features & Accessories. Model Options. Undercounter/Freestanding 24 W. Dual Zone Wine Cellar

HEATER POWER CONTROLLER

Jameco SKU Number:

General Purpose High Power PCB Relays

EPM Series Reversing Electric Actuators

Test Report: EDR-75-12

Model Crosspoint Matrix

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

REFRIGERATION. Standard Features & Accessories. Model Options. Undercounter/Freestanding 24 W. Wine Cellar

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

Test Report: HB


Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Emergency Stop Devices

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Engineering Design Assurance Test Report ( S )

DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I

Undercounter/Freestanding 15 W. Wine Cellar

SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications


Dialight LED High Bay - High Output. Technical Specification Sheet - Americas

Test Report: APC

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications #

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing


NK Multi-stage submersible pumps

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

320W Single Output with PFC Function

Test Report: EPS 15 12

Test Report: EPP

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

CEELOK FAS-T CONNECTORS

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Ball Valve Manual Balance Hose Kits - Submittal

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF

Test Report: IRM-05-05

MODEL CFD Forward Curved Belt Driven Inline Duct Blower

Test Report: EPP

NIBCO PNEUMATIC ACTUATORS

Test Report: IRM-20-24

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Test Report: GSM40A18

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

SUBMITTAL DATA SHEET COOLING PERFORMANCE HEATING PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE ELECTRICAL DATA TOTAL UNIT WEIGHT

Conservatory awning W8 Description

Product Guide LED OBSTRUCTION LIGHTS

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

AWNING CONTROL KIT 98GCK-33B

Test Report: IRM-05-24

Corrosion Control Equipment and Supplies

Vigilant LED High Bay Technical Specifications

PN 3000 Series Fail Closed Pneumatic Actuators

B-Series Switches Temperature Switches

WASHGUARD. More Than Just a Motor Company WASHDOWN DUTY PT PRODUCTS ELECTRIC MOTORS, GEAR REDUCERS, AC & DC DRIVES. Bulletin 1500

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Test Report: IRM-10-12

60W Single Output LED Power Supply

COCKPIT USB POWER INTEGRATION

Nexus Standard Glove Box System

Electrical Specifications. Dimensions (inches)

Big SHOT III Hybridization Oven

Electrical Specifications. Dimensions (inches)

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

General-Use Auto-Tuning HPX-T Series

Molded High-Voltage Bushing Wells

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:


630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) Internal fuse on both L and N lines.

Industry best 5 year fan housing warranty, 1 year motor warranty

Transcription:

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES UPS MIL-SPEC COMPLIANT 1-5 KVA 1-5 U UNIVERSAL 120/240 VAC PFC INPUT SNMP COMMUNICATIONS WHEN EVERY POUND COUNTS! APPLICATIONS Shelters Tactical Systems Shipboard Power Aircraft HMMWVs Mobile Systems Ground Support Transit Cases COMPLIANCE BY TEST OR SIMILARITY MIL-STD-810 MIL-S-901 MIL-STD-167 MIL-STD-461 MIL-STD-1399 MIL-S-704 DOD-STD-1399 100 School Street, Bergenfield, NJ 07621 Phone: (201) 385-0500 Fax: (201) 385-0702

F COMPACT CHASSIS (1U - 5U TALL) F ULTRA LIGHTWEIGHT DESIGN F POWER FACTOR CORRECTED UNIVERSAL INPUT F SNMP COMMUNICATIONS F LITHIUM PHOSPHATE BATTERIES AVAILABLE WHEN EVERY POUND COUNTS! Nova s Ultra Lightweight Galaxy-Series UPS Systems are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments in compliance to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD-1399. These models utilize True On-Line technology, offering maximum field-proven reliability for severe environment and high reliability applications such as: Military Applications Including HMMWV, UAV, Shipboard, Submarine, Aircraft, Mobile Power Units, Shelters, Transportable Systems, Tactical Systems, Ground Support, and more. Heavy-Duty Industrial Applications Demanding Commercial Applications Communications Systems

PROTECTIVE FEATURES AC & DC Input Circuit Breakers Low Battery Shut Off with Circuit Breaker Trip Overload & Thermal Protected Input Under/Overvoltage Protected Audible Alarm with Silence Switch ENVIRONMENTAL UPS Operating Temp.: -20 to +55 C (Extended ranges optional) UPS Storage temperature range: -40 to +71 C (Electronics Only - Extended ranges optional) Humidity: to 95% RH non-condensing All boards conformal coated with Acrylic MIL-I-46058 Type R. Elevation: 15,000 Ft. (4,572 m) operating; 40,000 Ft. (12,192 m) non-operating (Higher Optional) Shock: 20 g, 11 ms half sinewave Audible Noise: Less than 55 dba at 5 ft. MTBF: 100,000+ hours per field data @ +25C Ambient Ground-Fixed MTTR: 30 minutes by qualified personnel INDICATORS Status (Red / Green) UPS Off (Red) UPS Off (Red) Logic Fault (Red) Low Battery (Red) Over Temperature (Red) Load on Utility (Red) with optional transfer switch AUDIBLE Audible alarm with silence swich. COMMUNICATIONS SNMP V1.0 standard via CAT-5 Connector (V3.0 Optional) RS 232 (Available-Optional) Via DB 9 Connector Alarm Contacts (Available-Optional) Major Alarm: Logic Fault, Low Battery, OT, UPS Overloaded Minor Alarm: Utility Off, Load on Utility (With optional transfer switch)

AVAILABLE OPTIONS Power distribution units Ruggedization against high shock, vibration and humidity MS connector mates and multiple output outlets Chassis Slide Guides Internal transfer switch (static or electromechanical) Custom Enclosures Additional run time via external batteries 3Ø Power Input Premium VRLA batteries with up to 10 year life 400 Hz input and / or output LiFe models feature internal Lithium Iron Phosphate batteries for substantial weight savings and longer runtime, including embedded Battery Management System CAD Free Connectors Non-PVC wiring 28 VDC Input High IP Protection for front / rear panels AUX DC Outputs RTCA/DO-160G Compliant Aircraft Grade Package Typical IP32 Protection Package ELECTAL Input Voltage: Output Voltage: Frequency: SPECIFICATIONS Voltage Regulation: 120/240 VAC (110-250 VAC) PFC (3Ø input optional) 120, 208, or 230 VAC (specify) 50 / 60 / 400 Hz. Available ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: Input Power Factor: Efficiency at full load: Connections: 5% THD, 3% typical 0.95 or Better @ half-full load 80-85% @ full load typical (batteries charged) MS Connector (mates optional) NOMINAL DIMENSIONS: UPS Dimensions: 19 Wide x 24 Deep (See chart for height) Note: External batteries available on all models if increased run time is required up to 24 hours. External battery drawer typically 2-4U depending on requirements. BATTERIES Internal on all but 5KVA EXT models Standard sealed, maintenance free lead acid batteries have -20 C to +50 C storage range. Optional Premium sealed, maintenance free lead acid batteries have -40 C to +80 C operating range and useful life of 8-12 years @ +25 C ambient. Optional Lithium Iron Phosphate batteries (as shown in units with LiFe model suffix) have -20 C to +60 C operating range and useful life of 8-10 years @ +25 C ambient, but are much lighter than lead acid batteries and offer about twice the battery run time in the same volume battery pack.

120 VAC OUTPUT MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME HEIGHT GRSLPFC11-5K60-120/240A-120-5M-5U 5 4 120-240 VAC 26A 110 4 min @ 3 KW 5U GRSLPFC11-5K60-120/240A-120-5M-5U-LIFE 5 4 120-240 VAC 26A 75 4 min @ 3 KW 5U GRSLPFC11-5K60-120/240A-120-4U 5 4 120-240 VAC 26A 45 External 4U GRSLPFC11-3K60-120/240A-120-5M-4U 3 3 120-240 VAC 26A 95 5 min. 4U GRSLPFC11-3K60-120/240A-120-5M-4U-LIFE 3 3 120-240 VAC 24/12A 70 5 min. 4U GRSLPFC11-3K60-120/240A-120-10M-4U 3 2.4 120-240 VAC 24/12A 95 7 min. 4U GRSLPFC11-3K60-120/240A-120-5M-3U 3 2.4 120-240 VAC 24/12A 80 5 min. 3U GRSLPFC11-3K60-120/240A-120-5M-3U-LIFE 3 2.4 120-240 VAC 24/12A 65 5 min. 3U GRSLPFC11-2K60-120/240-120-5M-3U 2 1.6 120-240 VAC 16/8A 80 7 min. 3U GRSLPFC11-2K60-120/240-120-5M-3U-LIFE 2 1.6 120-240 VAC 16/8A 65 7 min. 3U GRSLPFC11-1.5K60-120/240A -120-5M-2U 1.5 1.2 120-240 VAC 12/6A 60 5 min. 2U GRSLPFC11-1.5K60-120/240A -120-5M-2U-LIFE 1.5 1.2 120-240 VAC 12/6A 37 5 min. 2U GRSLPFC11-1K60-120/240A-120-10M-1U-LIFE 0.9 0.7 120-240 VAC 8/4A 25 10 min. 1U 230 VAC OUTPUT MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME HEIGHT GRSLPFC11-5K50-120/240A-230-5M-5U 5 4 120-240 VAC 26A 110 4 min @ 3 KW 5U GRSLPFC11-5K60-120/240A-230-5M-5U-LIFE 5 4 120-240 VAC 26A 75 4 min @ 3 KW 5U GRSLPFC11-5K50-120/240A-230-5M-4U 5 4 120-240 VAC 26A 45 External 4U GRSLPFC11-3K50-120/240A-230-5M-4U 3 3 120-240 VAC 30/15A 95 5 min. 4U GRSLPFC11-3K60-120/240A-230-5M-4U-LIFE 3 3 120-240 VAC 30/15A 70 5 min. 4U GRSLPFC11-3K50-120/240A- 230-10M-4U 3 2.4 120-240 VAC 24/12A 95 7 min. 4U GRSLPFC11-3K50-120/240A -230-5M-3U 3 2.4 120-240 VAC 24/12A 80 5 min. 3U GRSLPFC11-3K60-120/240A-230-5M-3U-LIFE 3 2.4 120-240 VAC 24/12A 65 5 min. 3U GRSLPFC11-2K50-120/240A -230-5M-3U 2 1.6 120-240 VAC 16/8A 80 7 min. 3U GRSLPFC11-2K50-120/240A -230-5M-3U-LIFE 2 1.6 120-240 VAC 16/8A 65 7 min. 3U GRSLPFC11-1.5K50-120/240A -230-5M-2U 1.5 1.2 120-240 VAC 12/6A 60 5 min. 2U GRSLPFC11-1.5K50-120/240A -230-5M-2U-LIFE 1.5 1.2 120-240 VAC 12/6A 37 5 min. 2U GRSLPFC11-1K50-120/240A -230-10M-1U-LIFE 0.9 0.7 120-240 VAC 8/4A 25 10 min. 1U 3Ø INPUT MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME HEIGHT GRSLPFC11-5K60-120/208-120-5M-5U 5 4 120-208 VAC 3Ø 15A 110 4 min @ 3 KW 5U GRSLPFC11-5K60-120/208-5M-5U-LIFE 5 4 120-208 VAC 3Ø 15A 75 4 min @ 3 KW 5U GRSLPFC11-3K60-120/208-120-5M-4U 3 3 120-208 VAC 3Ø 11A 95 5 min. 4U GRSLPFC11-3K60-120/208-120-5M-4U-LIFE 3 3 120-208 VAC 3Ø 9A 70 5 min. 4U GRSLPFC11-3K60-120/208-120-10M-4U 3 2.4 120-208 VAC 3Ø 9A 95 7 min. 4U GRSLPFC11-3K60-120/208-120-5M-3U 3 2.4 120-208 VAC 3Ø 9A 80 5 min. 3U GRSLPFC11-3K60-120/208-120-5M-3U-LIFE 3 2.4 120-208 VAC 3Ø 9A 65 5 min. 3U GRSLPFC11-2K60-120/208-120-5M-3U 2 1.6 120-208 VAC 3Ø 6A 80 7 min. 3U GRSLPFC11-2K60-120/208-120-5M-3U-LIFE 2 1.6 120-208 VAC 3Ø 6A 65 7 min. 3U GRSLPFC11-1.5K60-120/208-120-5M-2U 1.5 1.2 120-208 VAC 3Ø 5A 60 5 min. 2U GRSLPFC11-1.5K60-120/208-120-5M-2U-LIFE 1.5 1.2 120-208 VAC 3Ø 5A 37 5 min. 2U

SYSTEM COMPLIANCE MIL-STD-1399 Section 300B: For Type I apparatus MIL-STD-740-1: Airborne Sound Measurements for Shipboard Equipment MIL-STD-740-2: Structureborne Vibratory Acceleration Measurements Additional Ruggedization to meet MIL-S-901, MIL-STD-167, MIL-STD-810, and DOD-STD-1399: The UPS System s construcon is extremely robust, and ruggedized throughout. All components and modules within the unit are mounted using additional steel brackets and heavy-duty stainless-steel hardware, which is then further secured using Loctite and RTV where required. All boards are conformal-coated (Acrylic MIL-I-46058 Type R) for maximum resistance to potential condensation and fungus growth. The unit was tested and qualified as follows: MIL-S-901D for Grade A, Class II, Type B Equipment (mounted in shock-isolated rack attenuating to 20g/11ms max) MIL-STD-167-1 for Type I Equipment MIL-STD-810 Air Temperature per MIL-STD-810F Method 502.4, Procedure II Steady State Temperature per MIL-STD-810F, Method 501.4, Procedure I (Constant Temperature) and Method 502.4, Procedure I Temperature Shock per MIL-STD-810F, Method 503.4, Procedure II, Cyclic Thermal Shock testing per MIL-STD-810G, Method 503.5, Procedure I-D Operating Temperature Shock per MIL-STD-810B Method 503 0 to 71 C High Temperature Storage per MIL-STD-810G, Method 501.5, Procedure I Low Temperature Storage testing per MIL-STD-810G, Method 502.5, Procedure I Operational Humidity per MIL-STD-810F Method 507.4 Humidity per MIL-STD-801G, Method 507.5, Procedure I Storage and Transportation Humidity per MIL-STD-810F, Method 507.4 Salt Fog Atmosphere per MIL-STD-810F Method 509.4 Altitude per MIL-STD-810F, Method 500.4, Procedure I, Storage/Air Transport Operating and Non-Operating Altitude Testing per MIL-STD-810G, Method 500.5, Procedure II Rapid Decompression per MIL-STD-810F, Method 500.4, Procedure III Transit Shock per MIL-STD-810F, Method 516, Procedures IV, V and VI Transportation Vibration per MIL-STD-810F, Method 514.5, Procedure II for loose cargo transportation Transportation Vibration per MIL-STD-810G, Method 514-6, Procedure I, Category 20 Vibration per MIL-STD-810B Method 514.6, Category 12, Procedure I Transit Drop per MIL-STD-810F, Method 516.5, Procedure IV Transit Drop per MIL-STD-810G, Method 516.6, Procedure IV Bench Handling per MIL-STD-810F, Method 516.5, Procedure VI Bench Handling per MIL-STD-810G, Method 516.6, Procedure VI DOD-STD-1399 Section 301A Table V Design Limits for Ship Motion Internal EMI Reduction Package to meet MIL-STD-461: The design of this unit is specifically focused on reducing EMI emissions. The UPS contains substantial internal filtering to minimize EMI emissions. Inputs which may be susceptible to transients are protected by several methods. The compact rack mount chassis is specifically treated with low surface resistivity finishes on the interior. All aluminum parts are treated with clear irridite. The steel parts are treated with zinc plate, followed by a clear chromate. Paint method via ANSI-61 gray is designed to assure excellent bonding of mating sheet metal parts. All input and output ventilation filters include metal honeycomb-style or mesh filters. The unit was tested and qualified as follows: MIL-STD-461E: CE101, CE102, CS101, CS114, CS116, RE102, RS101, and RS103 OPTIONAL COMPLIANCE WITH RCTA/DO-160G AIRCRAFT GRADE PACKAGE Qualifications to RTCA/DO-160G include: Rapid Decompression: Section 4 Cabin Pressure (8K) to Max Oper Alt (35K) in 15 sec; Hold for 10 min Crash Safety Sustained: Section 7, Cat B - Up = 3.0g - Down = 6.0g - Fwd = 9.0g - Aft = 1.5g - Side =4.0g Explosive Atmosphere: Non-Ignition Test Sec. 9.6.2, Cat E Qualifications to MIL-STD-810B include: Operating Temperature Shock per MIL-STD-810B Method 503 0 to 71 C Vibration per MIL-STD-810B Method 514.6, Category 12, Procedure I Note: Qualification testing was performed with optional premium batteries required to meet temperature testing requirements.

TYPICAL 1U CHASSIS Notes: 1. MS Connectors with mates optional 2. Chassis slides optional

EST. WEIGHT 60 LBS. VRLA BATTERIES 37 LBS. LIFE BATTERIES TYPICAL 2U CHASSIS

(OPTIONAL) OPTIONAL TYPICAL 3U CHASSIS

TYPICAL 4U CHASSIS

TYPICAL 5U CHASSIS

RUGGED AC POWER SYSTEMS UPS, INVERTERS & CONVERTERS DESIGNED TO MEET MIL-STD-810, MIL-STD-461, MIL-STD-1399 & MIL-STD-901 OPTIONALLY COMPATIBLE WITH GENERATOR INPUT RELIABLE AC POWER WHEN AND WHERE YOU NEED IT SEVERE ENVIRONMENT PRODUCTS AIRBORNE SHIPBOARD MOBILE & HMMWV RACK MOUNT & FREESTANDING 50, 60, AND 400 Hz AIR & WATER COOLED SINGLE AND THREE PHASE LIGHTWEIGHT DESIGNS 100 School Street, Bergenfield, NJ 07621 Phone: (201) 385-0500 Fax: (201) 385-0702 N12PGUPS2015