CENELEC SERIES SXTB Page,3,4 EExe T6 IP66 ASTH Page 5,6,7,8 EExe T6 IP66 STH Page 9,0,, EExd B T6 IP66 TESTING EQUIPMENT Page 3,4
INCREASED SAFETY TERMINAL BOX (EExe T6) SXTB APPLICATION: SPECIFICATION: MATERIAL: The terminal boxes are fitted with terminals of various sizes & numbers. Cable entries are provided according to order. The holes (hubs) are punched and cable glands are secured with counternuts. Suitable for use outdoors (IP66/IEC59) designed for use in hazardous areas where serious corrosion exist. Explosion protection ATEX CENELEC 0470 GD EExe T6 EExe CERTFICATION BODY : NEMKO (NORGES ELEKTRISKE MATERIAL KONTROLL) CERTIFICATE No. : 03ATEX67 (TERMINAL BOX) 03ATEX68U (ENCLOSURE) Stainless steel Canopy and Hood are available upon request. SXTB ASTH STH SXTB- TESTING EQUIPMENT - 4 - WEIGHT : kg (Enclosure) 6 6 6 6 6 6 3 3 3 0.5 8P 8P 4 7P 7P 6 5P 5P
INCREASED SAFETY TERMINAL BOX (EExe T6) SXTB- WEIGHT : 3.5kg (Enclosure) - 4 - B 5 3.5 5P 30P 4 P 4P 6 0P 0P 0 8P 8P 6 6P 6P 35 3P 3P SXTB-3 WEIGHT : 6kg (Enclosure) B 9 7 5-4 3-3.5 5P 3 75P 4 0P 3 60P 6 5P 5P 0 P 3 36P 6 0P 0P 35 7P 7P 3
SXTB-5 WEIGHT : 0kg (Enclosure) - 4 - B 36 9 7 4 7 5.5 45P 4 80P 4 40P 4 60P 6 35P 4 40P 0 8P 3 84P 6 P 3 66P 35 6P 6P SXTB ASTH STH TESTING EQUIPMENT 4
INCREASED SAFETY TERMINAL BOX (EExe T6) ASTH APPLICATION: SPECIFICATION: MATERIAL: The terminal boxes are fitted with terminals of various sizes & numbers. Cable entries are provided according to order. (Top/Bottom/Side) The holes (hubs) are threaded M/NPT/G upon request on the each surface. Suitable for use outdoors (IP66/IEC59) designed for use in hazardous areas. Explosion protection ATEX CENELEC 0470 GD EExe T6 EExe CERTFICATION BODY : NEMKO (NORGES ELEKTRISKE MATERIAL KONTROLL) CERTIFICATE No. : 03ATEX69 (TERMINAL BOX) 03ATEX70U (ENCLOSURE) Aluminum alloy casting FINISH: Standard surface finish will be epoxy resin painting (COLOR : 7.5BG 6/.5) suitable for corrosion proof but available according to order. Canopy and Hood are available upon request. ASTH-0-4 - WEIGHT : 5kg (Enclosure) 8 8 5 4 5 5 3 4 4 3 3.5 0P 0P 5P 30P 4 0P 0P P 4P 6 5P 5P 0P 0P 0 P P 8P 6P 6 0P 0P 6P P 35 6P 6P 4P 4P 5
ASTH-0-4 - WEIGHT : 7kg (Enclosure) 0 0 8 7 8 8 5 5 7 7 5 4 5 5 3 3 3.5 5P 50P 5P 5P 4 5P 5P 5P 5P 6 0P 0P P 3 36P 0 5P 5P 0P 0P 6 P P 8P 6P 35 0P 0P 6P 6P SXTB ASTH STH ASTH-30 TESTING EQUIPMENT WEIGHT : 8kg (Enclosure) - 4-4 4 8 7 9 9 5 5 7 7 5 4 5 5 3 4 4 3 3.5 30P 60P 5P 4 60P 4 30P 30P 5P 4 60P 6 5P 5P P 4 48P 0 0P 0P 0P 3 30P 6 5P 5P 8P 6P 35 P P 6P 6P 6
INCREASED SAFETY TERMINAL BOX (EExe T6) ASTH-60-4 - WEIGHT : 0kg (Enclosure) 8 8 8 7 3 3 5 5 0 0 5 4 8 8 3 5 5 4 4.5 45P 90P 5P 5 75P 4 45P 45P 5P 5 75P 6 36P 36P P 5 60P 0 30P 30P 0P 4 40P 6 4P 4P 8P P 35 8P 8P 6P 6P ASTH-70-4 - WEIGHT : 0kg (Enclosure) 4 4 3 9 8 8 8 5 4 7 7 4 3 5 5 4 3 3 3 3.5 30P 3 90P 30P 3 90P 4 8P 3 84P 8P 3 84P 6 5P 3 75P 5P 3 75P 0 0P 3 60P 0P 3 60P 6 4P 8P 4P 8P 35 8P 8P 8P 8P 7
ASTH-90-4 - WEIGHT : 5kg (Enclosure) 3 3 6 5 0 9 7 7 4 3 0 0 8 8 9 8 8 8 7 6.5 36P 4 44P 45P 4 80P 4 38P 4 36P 4P 4 68P 6 8P 4 P 34P 4 36P 0 P 3 66P 8P 3 84P 6 8P 3 54P P 3 66P 35 4P 4P 6P 6P SXTB ASTH STH TESTING EQUIPMENT 8
FLAMEPROOF TERMINAL BOX (EExd B T6) STH APPLICATION: SPECIFICATION: MATERIAL: The terminal boxes are fitted with terminals of various sizes & numbers. Cable entries are provided according to order. (Top/Bottom/Side) The holes (hubs) are threaded M/NPT/G upon request on the each surface. Suitable for use outdoors (IP66/IEC59) designed for use in hazardous areas. Explosion protection ATEX CENELEC 0470 GD EExd T6 EExd CERTFICATION BODY : NEMKO (NORGES ELEKTRISKE MATERIAL KONTROLL) CERTIFICATE No. : 03ATEX77 (TERMINAL BOX) 03ATEX78U (ENCLOSURE) Aluminum alloy casting FINISH: Standard surface finish will be epoxy resin painting (COLOR : 7.5BG 6/.5) suitable for corrosion proof but available according to order. Canopy and Hood are available upon request. STH- - 4 - WEIGHT : 4.5kg 5 5 3 3 4 4 3 3.5 7P 7P 7P 4P 4 6P 6P 6P P 6 3P 3P 5P 0P 0 0P 0P 3P 6P 9
STH-3-4 - WEIGHT: 7.5kg 8 7 0 0 5 5 7 7 3 3 5 5 3 3 3 3.5 30P 60P 3P 3 39P 4 6P 5P P 3 33P 6 P 4P 9P 3 7P 0 7P 34P 7P 3 P SXTB ASTH STH STH-5 TESTING EQUIPMENT WEIGHT:7kg - 4-6 6 0 0 4 4 7 7 5 5 0 0 5 4 7 7 4 4.5 40P 80P 8P 4 7P 4 38P 76P 6P 4 64P 6 30P 60P 3P 4 5P 0 5P 50P P 4 44P 6 8P 36P 6P P 35 0P 0P 5P 5P 0
FLAMEPROOF TERMINAL BOX (EExd B T6) STH-6-4 - STH-7 WEIGHT: 5kg 3 3 0 9 0 0 0 0 0 0 8 8 8 8 7 7 7 7 5 5.5 40P 3 0P 30P 4 0P 4 36P 3 08P 8P 4 P 6 8P 3 84P 0P 4 80P 0 P 3 66P 6P 4 48P 6 6P 3P P 4P 35 0P 0P 8P 8P - 4 - WEIGHT: 46kg 3 3 0 0 6 6 7 7 3 3 4 3 7 7 0 0 8 8 0 0 5 5.5 58P 3 74P 30P 6 80P 4 50P 3 50P 8P 5 40P 6 40P 3 0P 3P 5 5P 0 33P 3 99P 8P 5 90P 6 5P 50P 3P 3 39P 35 7P 7P 8P 6P
FLAMEPROOF TERMINAL BOX (EExd C T6) SXTB-04/06 TYPE SXTB-04 SXTB-06 5 8.3 50 06 6 00 9 35 88 9 0 89 8 30 65 WEIGHT kg 0.9.4 SXTB ASTH STH TYPE THREADS 4-WAY SXTB-04 SXTB-06 G G G G G G NPT NPT NPT NPT NPT NPT M6 M0 M5 M6 M0 M5 M3 TERMINAL SIZE.5mm 4mm 6mm.5mm 4mm 6mm 0mm NUMBER OF TERMINALS 4P 4P 4P 4P 4P 4P 8P 8P 8P 8P 6P 6P 4P 4P TESTING EQUIPMENT
TESTING EQUIPMENT TESTING EQUIPMENT Tests of ability of the enclosure to withstand pressure The object of this test is to verify that the enclosure to withstand the pressure of an internal explosion. Determination of Explosion Pressure (Reference Pressure) The reference is the highest value of the maximum smoothed pressure, relative to atmospheric pressure, observed during this test. Each Test consists of igniting an explosive mixture inside the enclosure and of measuring the pressure developed by the explosion. The mixture shall be ignited by one sparking Plug. The pressure developed during the explosion shall be determined and recorded during each test. The location of the sparking plug as well as those of the pressure gauges are left to the discretion of the testing station, to find the combination which produces the highest pressure. Removable gasket or O-rings can be fitted to the enclosure under testing. Explosion Testing Equipment Number of tests for Withstand pressure tests (Explosion tests) Number of tests are different depend on the specifications as follows: CENELEC STANDARD A will be 3 tests with propane gas B will be 3 tests with ethylene gas C will be 3 tests with acetylene gas and 3 tests with hydrogen gas JIS STANDARD d & d3 will be 0 tests with hydrogen gas Test for non-transmission of an internal ignition The same explosive mixture is introduced into the enclosure and the test chamber at atmospheric pressure. This test shall be made five times (for CENELEC) or fifteen times (for JIS). The test result is considered satisfactory if the ignition is not transmitted to the test chamber. Removable gasket or O-rings are to be removed under testing. The explosive mixture gas will be: Hydrogen, Ethylene, Acetylene and Propane 3
3 Dust Proof Test 5 Ingress Protection Test The object of this test is to verify that the enclosure to withstand the dust-proof of an external dust. The sample enclosure is placed in the Dust proof Testing Equipment where 00 mesh dust is continuously supplied at a rate of kg/cm 3 to reduce the enclosure internal pressure to be approx. 00mmHO(96Pa). The period of application of the pressure shall be at least hours. Dust Proof Testing Equipment The enclosure for outdoor use should be of water proof construction. This equipment is used to check for water leaks into the enclosures. Water Splash Testign Equipment SXTB ASTH STH 4 Temperature & Humidity Test 6 Falling Weight Impact Test In order to determine safety of explosion protected enclosure against ignition of explosive gases. This equipment(bath) measures temperature of enclosure in the constant temperature room. Room temperature determined and temperature rise to be recorded by the controller outside. The object of this test is to verify that the enclosure to withstand the mechanical strength of cover and body by dropping a steel ball of a specified weight on the weakest surface of cover and body from specified height. TESTING EQUIPMENT High Temperature & Constant Humidity Bath 4