CENELEC SERIES. SXTB Page 2,3,4 EExe T6 IP66. ASTH Page 5,6,7,8. STH Page 9,10,11,12 EExd B T6 IP66. EXPLOSION PROOF TESTING EQUIPMENT Page 13,14

Similar documents
SFC /SFCS

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

ANACONDA SEALTITE CONDUIT TYPE NMFG BLUE

WARNING DEVICES ATEX. V.le Rimembranze, Sesto S. G. (MI) ITALY Ph.: a.r. Fax:

Eclipse Hermetic Gas Boosters Series HB

B-Series Switches Temperature Switches

Emergency Stop Devices

Sealing and terminating Wrexham Mineral Cables

CENTRAL MARKS DEPARTMENT-III

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

Bourdon Tube Pressure Switches

Model SBS-10. Stainless Steel Simplex Basket Strainer. 21 Columbus Avenue Garfield, NJ 07026

CABLE GRIPS CABLE GRIPS

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

Cover, 1 Gang; Malleable Iron; Zinc Electroplated Dichromate Aluminum Polymer Enamel; Box Mounting; Appleton[R] Brand; FS Model; With Square Handle

Molded High-Voltage Bushing Wells

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.


WASHGUARD. More Than Just a Motor Company WASHDOWN DUTY PT PRODUCTS ELECTRIC MOTORS, GEAR REDUCERS, AC & DC DRIVES. Bulletin 1500

a Nexans company Catalogue 2009

Inflatable Tent. Medical, Decontamination, Activity

Internal Safety Cabinets

1152 Wall Mounted Drinking Fountain

Pallet Feet & Fittings SQUARE

NK Multi-stage submersible pumps

PN 3000 Series Fail Closed Pneumatic Actuators

TC42 TRANQUILITY BURNER KIT INSTRUCTIONS

TECHNICAL BROCHURE BPRIMELINE R1. Marlow Series Prime Line SELF-PRIMING CENTRIFUGAL PUMPS TECHNICAL DATA

The Biolite Woodgas Campstove

Page 92

Hammer, Discus, Shot Put, Javelin

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

B-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic

OAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits

Smallest Connector with Removable Contacts

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW

Icelock Ratchet 621 Icelock Lanyard 631 Icelock Valve 641 Icelock Smooth 651

SafeSite. Series LED Based Signaling for Hazardous Locations

T&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings

Industry best 5 year fan housing warranty, 1 year motor warranty

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

get connected with Bradford fittings & valves Bradford Company, Inc

TENTS, CANOPIES AND TEMPORARY MEMBRANE STRUCTURES

NEW PRODUCT. Turn to the Harris. Pros

Specifications of KINEDIZER burners

Advanced Customization Type 1. White Paper

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

SafeSite LED Floodlight - UL 844 for Indoor and Outdoor Hazardous Applications

Swagelok Hose. Adding Flexibility to your Fluid Systems

Ground Clamps Cable Tray

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

SafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1 MDTEXSSFLX001_B

DOMESTIC LPG STOVE. Profile No.: 46 NIC Code: INTRODUCTION: 2. PRODUCT & ITS APPLICATION:

Russellstoll. Electrical Interconnection Systems. Dura-Gard Nonmetallic Waterproof Connections. The Next Generation: Dura-Gard

FIBER OPTIC CLOSURES

Foam Systems Engineering Design Manual

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information

2-3-5 Valve Manifolds

RING VAC AIR CONVEYOR TYPES OF RING VACS

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

Valves valves

Vacuum Hose Reel 881 Ex

RING VAC Convey solid materials, waste, trim, small parts with virtually no moving parts. 4Made of anodized aluminum with no moving parts. material.

Trapped Key Transfer System SHGV SVM SVE

SIDE MOUNTING FLOAT SWITCH

SECTION I-1. Type: 1812-AC. Fuel: Air-Gas.

JD Burford Limited Unit 2D Hirwaun Industrial Estate Aberdare, South Wales, UK, CF44 9UP

Nexus Standard Glove Box System

8" 9000, " x 25" How to Specify NH-24

SPECIAL FEATURE of OSHA Safety Lock Tag Padlock :

SafeSite LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Applications

Metal & Teflon Lined Hose

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER


ROYAL CANADIAN AIR CADETS PROFICIENCY LEVEL ONE INSTRUCTIONAL GUIDE SECTION 1 EO C WATCH HOW IT S MADE SEGMENTS PREPARATION

34070 Sec13 SpecialtyV1 6/21/03 12:17 PM Page 339 SPECIALTY TOOLS 13

DUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076

Sales support Global website

MINISPRAYJET. MINISPRAYJET Flame spraying gun THE WHOLE WORLD OF GAS SAFETY ENGINEERING

Chip Vac Chip Vac Vacuums chips directly into an open-top drum with no moving parts! What Is The Chip Vac? Why The Chip Vac? Watch the video!

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

industrial ball valves

Vigilant LED High Bay - CE Technical Specifications

WILKINS 575A WILKINS 575 SIZE 3/4",1",1 1/4",1 1/2",2",21/2",3",4",6"

SIZE RANGE: 1 TO 10. PRESSURE RANGE: FULL VACUUM TO 275 psi

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL

Safety Interlock Switches

MODEL CFD Forward Curved Belt Driven Inline Duct Blower

TECHNICAL DATA SHEET

Diamond RealSeal Plastic Laboratory Bottles

UNISPRAYJET Flame spraying gun THE WHOLE WORLD OF GAS SAFETY ENGINEERING

Transcription:

CENELEC SERIES SXTB Page,3,4 EExe T6 IP66 ASTH Page 5,6,7,8 EExe T6 IP66 STH Page 9,0,, EExd B T6 IP66 TESTING EQUIPMENT Page 3,4

INCREASED SAFETY TERMINAL BOX (EExe T6) SXTB APPLICATION: SPECIFICATION: MATERIAL: The terminal boxes are fitted with terminals of various sizes & numbers. Cable entries are provided according to order. The holes (hubs) are punched and cable glands are secured with counternuts. Suitable for use outdoors (IP66/IEC59) designed for use in hazardous areas where serious corrosion exist. Explosion protection ATEX CENELEC 0470 GD EExe T6 EExe CERTFICATION BODY : NEMKO (NORGES ELEKTRISKE MATERIAL KONTROLL) CERTIFICATE No. : 03ATEX67 (TERMINAL BOX) 03ATEX68U (ENCLOSURE) Stainless steel Canopy and Hood are available upon request. SXTB ASTH STH SXTB- TESTING EQUIPMENT - 4 - WEIGHT : kg (Enclosure) 6 6 6 6 6 6 3 3 3 0.5 8P 8P 4 7P 7P 6 5P 5P

INCREASED SAFETY TERMINAL BOX (EExe T6) SXTB- WEIGHT : 3.5kg (Enclosure) - 4 - B 5 3.5 5P 30P 4 P 4P 6 0P 0P 0 8P 8P 6 6P 6P 35 3P 3P SXTB-3 WEIGHT : 6kg (Enclosure) B 9 7 5-4 3-3.5 5P 3 75P 4 0P 3 60P 6 5P 5P 0 P 3 36P 6 0P 0P 35 7P 7P 3

SXTB-5 WEIGHT : 0kg (Enclosure) - 4 - B 36 9 7 4 7 5.5 45P 4 80P 4 40P 4 60P 6 35P 4 40P 0 8P 3 84P 6 P 3 66P 35 6P 6P SXTB ASTH STH TESTING EQUIPMENT 4

INCREASED SAFETY TERMINAL BOX (EExe T6) ASTH APPLICATION: SPECIFICATION: MATERIAL: The terminal boxes are fitted with terminals of various sizes & numbers. Cable entries are provided according to order. (Top/Bottom/Side) The holes (hubs) are threaded M/NPT/G upon request on the each surface. Suitable for use outdoors (IP66/IEC59) designed for use in hazardous areas. Explosion protection ATEX CENELEC 0470 GD EExe T6 EExe CERTFICATION BODY : NEMKO (NORGES ELEKTRISKE MATERIAL KONTROLL) CERTIFICATE No. : 03ATEX69 (TERMINAL BOX) 03ATEX70U (ENCLOSURE) Aluminum alloy casting FINISH: Standard surface finish will be epoxy resin painting (COLOR : 7.5BG 6/.5) suitable for corrosion proof but available according to order. Canopy and Hood are available upon request. ASTH-0-4 - WEIGHT : 5kg (Enclosure) 8 8 5 4 5 5 3 4 4 3 3.5 0P 0P 5P 30P 4 0P 0P P 4P 6 5P 5P 0P 0P 0 P P 8P 6P 6 0P 0P 6P P 35 6P 6P 4P 4P 5

ASTH-0-4 - WEIGHT : 7kg (Enclosure) 0 0 8 7 8 8 5 5 7 7 5 4 5 5 3 3 3.5 5P 50P 5P 5P 4 5P 5P 5P 5P 6 0P 0P P 3 36P 0 5P 5P 0P 0P 6 P P 8P 6P 35 0P 0P 6P 6P SXTB ASTH STH ASTH-30 TESTING EQUIPMENT WEIGHT : 8kg (Enclosure) - 4-4 4 8 7 9 9 5 5 7 7 5 4 5 5 3 4 4 3 3.5 30P 60P 5P 4 60P 4 30P 30P 5P 4 60P 6 5P 5P P 4 48P 0 0P 0P 0P 3 30P 6 5P 5P 8P 6P 35 P P 6P 6P 6

INCREASED SAFETY TERMINAL BOX (EExe T6) ASTH-60-4 - WEIGHT : 0kg (Enclosure) 8 8 8 7 3 3 5 5 0 0 5 4 8 8 3 5 5 4 4.5 45P 90P 5P 5 75P 4 45P 45P 5P 5 75P 6 36P 36P P 5 60P 0 30P 30P 0P 4 40P 6 4P 4P 8P P 35 8P 8P 6P 6P ASTH-70-4 - WEIGHT : 0kg (Enclosure) 4 4 3 9 8 8 8 5 4 7 7 4 3 5 5 4 3 3 3 3.5 30P 3 90P 30P 3 90P 4 8P 3 84P 8P 3 84P 6 5P 3 75P 5P 3 75P 0 0P 3 60P 0P 3 60P 6 4P 8P 4P 8P 35 8P 8P 8P 8P 7

ASTH-90-4 - WEIGHT : 5kg (Enclosure) 3 3 6 5 0 9 7 7 4 3 0 0 8 8 9 8 8 8 7 6.5 36P 4 44P 45P 4 80P 4 38P 4 36P 4P 4 68P 6 8P 4 P 34P 4 36P 0 P 3 66P 8P 3 84P 6 8P 3 54P P 3 66P 35 4P 4P 6P 6P SXTB ASTH STH TESTING EQUIPMENT 8

FLAMEPROOF TERMINAL BOX (EExd B T6) STH APPLICATION: SPECIFICATION: MATERIAL: The terminal boxes are fitted with terminals of various sizes & numbers. Cable entries are provided according to order. (Top/Bottom/Side) The holes (hubs) are threaded M/NPT/G upon request on the each surface. Suitable for use outdoors (IP66/IEC59) designed for use in hazardous areas. Explosion protection ATEX CENELEC 0470 GD EExd T6 EExd CERTFICATION BODY : NEMKO (NORGES ELEKTRISKE MATERIAL KONTROLL) CERTIFICATE No. : 03ATEX77 (TERMINAL BOX) 03ATEX78U (ENCLOSURE) Aluminum alloy casting FINISH: Standard surface finish will be epoxy resin painting (COLOR : 7.5BG 6/.5) suitable for corrosion proof but available according to order. Canopy and Hood are available upon request. STH- - 4 - WEIGHT : 4.5kg 5 5 3 3 4 4 3 3.5 7P 7P 7P 4P 4 6P 6P 6P P 6 3P 3P 5P 0P 0 0P 0P 3P 6P 9

STH-3-4 - WEIGHT: 7.5kg 8 7 0 0 5 5 7 7 3 3 5 5 3 3 3 3.5 30P 60P 3P 3 39P 4 6P 5P P 3 33P 6 P 4P 9P 3 7P 0 7P 34P 7P 3 P SXTB ASTH STH STH-5 TESTING EQUIPMENT WEIGHT:7kg - 4-6 6 0 0 4 4 7 7 5 5 0 0 5 4 7 7 4 4.5 40P 80P 8P 4 7P 4 38P 76P 6P 4 64P 6 30P 60P 3P 4 5P 0 5P 50P P 4 44P 6 8P 36P 6P P 35 0P 0P 5P 5P 0

FLAMEPROOF TERMINAL BOX (EExd B T6) STH-6-4 - STH-7 WEIGHT: 5kg 3 3 0 9 0 0 0 0 0 0 8 8 8 8 7 7 7 7 5 5.5 40P 3 0P 30P 4 0P 4 36P 3 08P 8P 4 P 6 8P 3 84P 0P 4 80P 0 P 3 66P 6P 4 48P 6 6P 3P P 4P 35 0P 0P 8P 8P - 4 - WEIGHT: 46kg 3 3 0 0 6 6 7 7 3 3 4 3 7 7 0 0 8 8 0 0 5 5.5 58P 3 74P 30P 6 80P 4 50P 3 50P 8P 5 40P 6 40P 3 0P 3P 5 5P 0 33P 3 99P 8P 5 90P 6 5P 50P 3P 3 39P 35 7P 7P 8P 6P

FLAMEPROOF TERMINAL BOX (EExd C T6) SXTB-04/06 TYPE SXTB-04 SXTB-06 5 8.3 50 06 6 00 9 35 88 9 0 89 8 30 65 WEIGHT kg 0.9.4 SXTB ASTH STH TYPE THREADS 4-WAY SXTB-04 SXTB-06 G G G G G G NPT NPT NPT NPT NPT NPT M6 M0 M5 M6 M0 M5 M3 TERMINAL SIZE.5mm 4mm 6mm.5mm 4mm 6mm 0mm NUMBER OF TERMINALS 4P 4P 4P 4P 4P 4P 8P 8P 8P 8P 6P 6P 4P 4P TESTING EQUIPMENT

TESTING EQUIPMENT TESTING EQUIPMENT Tests of ability of the enclosure to withstand pressure The object of this test is to verify that the enclosure to withstand the pressure of an internal explosion. Determination of Explosion Pressure (Reference Pressure) The reference is the highest value of the maximum smoothed pressure, relative to atmospheric pressure, observed during this test. Each Test consists of igniting an explosive mixture inside the enclosure and of measuring the pressure developed by the explosion. The mixture shall be ignited by one sparking Plug. The pressure developed during the explosion shall be determined and recorded during each test. The location of the sparking plug as well as those of the pressure gauges are left to the discretion of the testing station, to find the combination which produces the highest pressure. Removable gasket or O-rings can be fitted to the enclosure under testing. Explosion Testing Equipment Number of tests for Withstand pressure tests (Explosion tests) Number of tests are different depend on the specifications as follows: CENELEC STANDARD A will be 3 tests with propane gas B will be 3 tests with ethylene gas C will be 3 tests with acetylene gas and 3 tests with hydrogen gas JIS STANDARD d & d3 will be 0 tests with hydrogen gas Test for non-transmission of an internal ignition The same explosive mixture is introduced into the enclosure and the test chamber at atmospheric pressure. This test shall be made five times (for CENELEC) or fifteen times (for JIS). The test result is considered satisfactory if the ignition is not transmitted to the test chamber. Removable gasket or O-rings are to be removed under testing. The explosive mixture gas will be: Hydrogen, Ethylene, Acetylene and Propane 3

3 Dust Proof Test 5 Ingress Protection Test The object of this test is to verify that the enclosure to withstand the dust-proof of an external dust. The sample enclosure is placed in the Dust proof Testing Equipment where 00 mesh dust is continuously supplied at a rate of kg/cm 3 to reduce the enclosure internal pressure to be approx. 00mmHO(96Pa). The period of application of the pressure shall be at least hours. Dust Proof Testing Equipment The enclosure for outdoor use should be of water proof construction. This equipment is used to check for water leaks into the enclosures. Water Splash Testign Equipment SXTB ASTH STH 4 Temperature & Humidity Test 6 Falling Weight Impact Test In order to determine safety of explosion protected enclosure against ignition of explosive gases. This equipment(bath) measures temperature of enclosure in the constant temperature room. Room temperature determined and temperature rise to be recorded by the controller outside. The object of this test is to verify that the enclosure to withstand the mechanical strength of cover and body by dropping a steel ball of a specified weight on the weakest surface of cover and body from specified height. TESTING EQUIPMENT High Temperature & Constant Humidity Bath 4