Instructions for Converting Range Top to Operate on Liquefied Petroleum Gas

Similar documents
Instructions for Converting Range to Operate on Liquefied Petroleum Gas

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

GRLP4 CONVERSION KiT APPLiCATiON instructions

NATURAL GAS CONVERSION KIT

GRLP3 CONVERSION KiT APPLiCATiON instructions

Installation GUIDE. NKVGR Natural Conversion Kit for 7 Series Ranges/Rangetops

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

CONVERSION INSTRUCTIONS

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

CONVERSION INSTRUCTIONS

Gas Conversion Kits and Instructions

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

TCWS.54NG03C2 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

TCWS54 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC36 SEE-THRU LODGEWOOD BURNER AND PANEL KIT INSTRUCTIONS

TC42 TRANQUILITY BURNER KIT INSTRUCTIONS

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

REPLACEMENT PROCEDURE: ROTISSERIE ORIFICE: TOOLS REQUIRED TO INSTALL THIS KIT: ITEM DESCRIPTION: E C

TC36 SEE-THRU CHALET BURNER KIT INSTRUCTIONS

TB131. Gas Conversion Kits for NVx & VPC Heaters. Issue 1.0 May Applies to models: NVx & VPC

ASSEMBLY GUIDE. Customer Service: INCH² 3-BURNER & 545 INCH² 3-BURNER

TC42 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

Stonefire Fire Pit Table. Installation Instructions for SF-32-K

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

Thermostatic Griddle Field Service Kit Instructions

Installer: Leave This Manual with Consumer Consumer: Save this Manual for Future Reference

Assembly/Installation/Use Instructions:

Brooks Fire Pit Table. Installation Instructions for Brooks Fire Pit Table BRK-1224

Genesis. Side Burner Accessory Installation. Step 3. Step 1. Step 2. For use with Genesis Gas Barbecues Only

Boardwalk Fire Pit Table

Style # Laguna Propane Tank Cover Owner s Manual

t420 Barbecue Assembly Manual

Dowload the specific conversion instructions for YOUR grill. This Natural Gas Conversion Kit can be used ONLY with the following approved grills:

TECHNICAL SUPPORT HOT LINE HOURS: 7:30-3:30

Gas Supply Conversion and Orifice Replacement Guide

Colonial and Grand Colonial Fire Pit Tables. Installation Instructions for

Quick Assembly Barbecue Assembly Manual

S420 Barbecue Assembly Manual

280 Propane Barbecue Assembly Manual

Fire Pit Tables. Installation Instructions. Sierra, San Juan, Grandstone, Rivers Edge, Pike s Peak. 1 P a g e

Uptown Fire Pit Table

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

Gas Go Anywhere /23/01

30-INCH FREE- STANDING GAS RANGE. Model No. FGGF3054K. Owner's Guide Installation Instructions Service Data Sheet

Key Largo Fire Pit. Installation Instructions. 1 P a g e. NorthlineExpress.com. Toll-Free

Urea/Adblue Hose Reel

Hose Reel Series L701/G701

A WARNING A IMPORTANT INSTALLATION AND OPERATION INSTRUCTIONS

OW LEE CASUAL FIRESIDE Q&A

INFRARED BURNER KIT INSTRUCTIONS

36-INCH FREE STANDING DUAL FUEL RANGE. Model No. E36DF76G P70S1

Napa Valley Fire Pit Table

30-INCH FREE- STANDING GAS RANGE. Model No. FGGF3054K

SECTION 8 PARTS LIST WITH EXPLODED VIEWS

Getting Started Guide

2 Burner ASSEMBLY MANUAL

ASSEMBLY & OPERATING INSTRUCTIONS POWER BURNER, L.P. (PROPANE) POWER BURNER, N.G. (NATURAL GAS)

LEG KIT. Pizza Oven OWNER S MANUAL. For 6000 Series Portable Ovens

S405 Barbecue Assembly Manual

SERVICE MANUAL V-SERIES HEAVY DUTY BROILERS, DOUBLE DECK AND RANGE MATCH MODELS - NOTICE - For a complete listing of models, see the MODELS section.

30-INCH FREE- STANDING GAS RANGE. Model No. FPGF3081K. Owner's Guide Installation Instructions Service Data Sheet

CHALET BURNER KIT TC42.NG01

PROPANE & HIGH ALTITUDE CONVERSION INSTRUCTIONS

Alcott Fire Table. Installation Instructions for ALC-1224

Advantage Plus TIM-3600 Series Reel

LOUISIANA BURNER / The Millers and the staff of Louisiana Burner

SHOWER CONVERSION KIT WITH HAND SHOWER

ER36D Range. IMPORTANT: This model is not approved for field conversions from one gas type to another and from one altitude setting to another.

LP Grill and Gas Hose

r e - p a r t s. c o m

SPK3E - Manual EASY Control

ER36D Range. IMPORTANT: This model is not approved for field conversions of gas types or altitude settings.

BigStack. Minimum Crossbar spread 24 For factory racks: Check fitlist notes, or Yakima.com for your vehicle s crossbar spread.

Professional Series Galley Range

Stone Arch Fireplace

WELCOME TO THE WORLD OF BARBEQUES GALORE OUTDOOR COOKING

FPPK-UN Control Kit Installation & Operating Instructions (Pan and Burner not included)

GAS SEALED BURNER USE AND CARE MANUAL AND INSTALLATION INSTRUCTIONS NOTE TO CONSUMER: NOTE TO INSTALLER:

COOK & GRILL STOVE. Model ASSEMBLY AND OPERATING INSTRUCTIONS

Sierra Linear Fire Pit Table. Installation Instructions for Sierra Fire Pit Table

Pine Ridge Fire Pit Table. Installation Instructions for Pine Ridge fire pit models PR-1242-K and PR-2424-K

Save these instructions!

30-INCH FREE- STANDING GAS RANGE. Model No. GLGFZ386F

For converting 72 PKN for use with (LP) propane gas.

The Wave. Installation Instructions for WV-56 Table

The Cove Fire Pit. Installation Instructions for CV-30

GLGFS66CBC GLGFS66CQC GLGFS66CSC

3 Burner ASSEMBLY MANUAL

TC36 COUNTRY HOME BURNER KIT INSTRUCTIONS (NATURAL GAS ONLY)

OW LEE CASUAL FIRESIDE Q&A

HAND HELD BALL VALVE & DETENT STYLE BALL VALVES

Transcription:

Instructions for Converting Range Top to Operate on Liquefied Petroleu Gas INSTALLATION AND SERVICES MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT: SAVE INSTRUCTION MANUAL FOR THE LOCAL INSPECTOR S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE This conversion kit ust be installed by a qualified service technician in accordance with the anufacturer's instructions and all applicable codes and requireents of the authority having jurisdiction. Failure to follow instructions ay result in fire, explosion or production of carbon onoxide causing property daage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and coplete until the operation of the converted appliance is checked as specified in the anufacturer's instructions supplied with this kit. Before proceeding with the conversion, shut off the gas supply before disconnecting electrical power to the range. Be sure power supplies are off before installing the conversion kit. Failure to do so could cause serious bodily injury. Deterine the cobination of top burners that are featured on your range. Identify the parts you need fro this kit to coplete the L.P. conversion. When burners are converted fro natural to L.P. the BTU ratings are as follows: Note: For operation at elevations above 2000ft., appliance rating shall be reduced at the rate of 4% for each 1000 ft. above sea level. Top Burner Sier Griddle burner Burner Oven Burner Broil Burner BTU 18000 15000 12000 9000 6000 15000 22000 14000 16500 13000 Orifice Size 1.22/ 1.24 1.07/ 1.10 1.0 0.8 0.72 0.34 1.16/ 1.22 1.32 1.10 1.18 1.05 HRG3078U NA 1 2 1 NA 1 NA 1 NA NA 1 5 HRG3080U 1 1 2 NA NA 1 NA 1 NA NA 1 5 HRG3031U NA 2 2 NA NA 2 NA 1 NA 1 NA 6 HRG3026U 2 2 NA NA NA 2 NA 1 NA 1 NA 6 HRG3609U NA 2 2 NA NA 2 1 1 NA 1 NA 6 HRG3617U 2 2 NA NA NA 2 1 1 NA 1 NA 6 HRG3603U NA 2 2 2 NA 2 NA 1 NA 1 NA 8 HRG3618U 1 2 3 NA NA 2 NA 1 NA 1 NA 8 HRG4804U NA 3 3 NA NA 3 1 1 1 1 NA 9 HRG4808U 3 3 NA NA NA 3 1 1 1 1 NA 9 HRD3088U 1 1 2 NA NA 1 NA NA NA NA NA 5 HRD3606U 3 2 1 NA NA 2 NA NA NA NA NA 8 HRD4803U 2 2 2 NA NA 2 1 NA NA NA NA 8 HRT3003U 2 NA 2 NA NA NA NA NA NA NA NA NA HRT3618U 1 2 3 NA NA 2 NA NA NA NA NA 8 Bypass Jet

Instructions for Converting Range Top to Operate on Liquefied Petroleu Gas IMPORTANT: After replacing the natural gas to LP orifices, be sure to keep the original factory installed natural gas orifices for future range conversion back to natural gas. Tools Required for L.P. Conversion: 7 Nut Driver (for dual burner ain orifice) 6 Nut Driver (for dual burner sier orifice) Adjustable wrench **IMPORTANT** 15000 BTU Dual Burner Main Burner Orifice 1.07 Sier Orifice for LP 0.38/0.34 18000 BTU Single Burner Burner Orifice for LP 1.24/1.22 12000 BTU Single Burner Burner Orifice for LP 1.00 1. Convert the Pressure Regulator For the Range Top, the gas pressure regulator is located at botto right of the range top. a. Electrical shock hazard can occur and result in injury or death. Disconnect electrical power to the range before servicing. Do not reove regulator or allow it to turn during servicing. b. Unscrew the cap fro the regulator. Do not reove the spring fro the regulator. c. Unscrew the plastic insert fro the cap and turn it over so the longer ste is facing the cap. To see the difference between NG and LP, please check the detailed pictures shown below:

Instructions for Converting Range Top to Operate on Liquefied Petroleu Gas Positon for NG Positon for LP **IMPORTANT** Pay attention that the NG and LP are in different direction. All the gas ranges are initially designed with NG position, please have it changed in to LP position. 2.Convert Top Burner for LP/ Propane Gas A. HRT3003U HRT3003U: Left front burner 18K BTU, right front burner 18K BTU, left rear burner 12K BTU, right rear burner 12K BTU. a. Reove cooking grates, burner caps and inner flae ring base, b. Check the burner Orifice and use 7 hexagonal Socket to screw out the NG orifice and screw it in with LP orifice. For 18K Burner, the orifice is 1.22/1.24; for 12K Burner, the orifice is 1.00. c. For the burner valve part, HRT3003U odel s valve design is available for both NG and LP gas, so no bypass is needed for LP conversion.

Instructions for Converting Range Top to Operate on Liquefied Petroleu Gas (left one is for 18K single burner, right one is for 12K single burner). B. HRT3618U HRT3618U: Left front burner 15K BTU dual burner, right front burner 15K BTU dual burner, iddle front burner 18K BTU single burner; left rear burner 12K BTU, right rear burner 12K BTU, iddle rear burner 12K BTU. a. Reove cooking grates, burner caps and inner flae ring base, b. Check the burner Orifice and use 7 hexagonal Socket to screw out the NG orifice and screw it in with LP orifice. For 18K Burner, the orifice is 1.22/1.24; for 12K Burner, the orifice is 1.00.For 15K dual burner Main orifice, it s 1.07/1.1; Use 6 hexagonal Socket to screw out the 15K dual burner sier orifice. For sier orifice, it s 0.34. ** A sall folded piece of scotch tape (sticky side out) inserted in to the socket will help hold the orifice in place**.

Instructions for Converting Range Top to Operate on Liquefied Petroleu Gas c. For the burner valve part, HRT3003U odel s valve design is available for both NG and LP gas, so no bypass is needed for LP conversion IMPORTANT to identify their arkings. c.1. Replace the ain orifice for dual burner 15000BTU with orifice size 1.07/1.10 (they are both working fine with the LP 15000BTU burner ain orifice). c.2. Replace the 18000BTU burner orifice in each with orifice size 1.22/1.24 (they are both working fine with the LP 18000BTU burner). c.3 Replace the 12000BTU burner orifice in each with orifice size 1.0. Please reeber not to over tighten the orifice and keep the orifice clean. d. Put the outer burner heads back to the ain burner bases. Put the inner burner rings, burner caps and cooking grate back as well. 3. Convert Burner Valves for LP/Propane Gas (only for HRT3618U Range Top) a. Reove control knobs, bezel and control panel b Using a flat screwdriver, replace gas valve bypass jets with bypass jets for LP c Save the ain bypass jets, in the plastic bag labeled ain jets and sier bypass jets in the bag for sier jets. When you are using your top burners, if the flae needs to be adjusted accordingly to fit your need, please adjust the bypass orifices on the burner valve. Put back the knob on and adjust the flae by rotating the bypass via a sall flat screw driver. Check the flae s condition to get the best perforance. For single valve, it has one bypass orifice; For Dual valve, it has two bypass orifices: left botto one for sier adjustent and right front one for ain burner adjustent.

Instructions for Converting Range Top to Operate on Liquefied Petroleu Gas 4. Reconnect Gas and Electrical Supply to Range. Leak testing of the appliance shall be conducted according to the installation instructions provided with the range. Checking for Manifold Gas Pressure If it is necessary to check the anifold gas pressure, reove the burner cap, inner ring, outer burner head and burner base of the right front top burner and connect a anoeter (water gauge) or another pressure test device to the burner orifice. Use a rubber hose with inside diaeter of approxiately ¼ and hold the end of the tube tight over the orifice. Turn the gas valve on. For a ore accurate pressure check, have at least two other top burners burning. Be sure that the gas supply (inlet) pressure is at least one inch above the specified anifold pressure. The gas supply pressure should never be over 14 water colun. When properly adjusted the anifold water colun pressure is 10 for LP/Propane gas or 5 for Natural Gas. Do not use a flae to check for gas leaks a. Disconnect the range and its individual shut-off valve fro the gas supply piping syste during any pressure of that syste at test pressures greater than 14 of water colun pressure (approxiately ½ psig) b. The appliance ust be isolated fro the gas supply piping syste by closing its individual anual hut-off valve during any pressure testing of the supply syste at test pressure equal to or less than 14 water colun pressure (approxiately ½ psig)