Quick Start Guide 3500 AquaVent

Similar documents
MyTraveler User s Manual

Video Media Center - VMC 1000 Getting Started Guide

ultimate traffic Live User Guide

S-Series Hotel App User Guide

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

SKYTRAK REAL GAME REAL RESULTS. Quick Start Guide

Power Tong Torque Manual

CruisePay Enhancements for 2005 Training Guide Version 1.0

UM1868. The BlueNRG and BlueNRG-MS information register (IFR) User manual. Introduction

MYOB EXO OnTheGo. Release Notes 1.2

myldtravel USER GUIDE

TRT800 ATC Transponder Mode A, A-C, S P/N 800ATC-(1XX)-(1XX) Operation Manual. Document No.: e Revision 1.00 Datum:

Smart-UPS Installation Guide 750/1000/1500/2200/3000 VA 120/230 Vac 500 VA 100 Vac Tower Important Safety Messages

A New Way to Work in the ERCOT Market

Dell EMC Unisphere 360

Installation Guide. Unisphere Central. Installation. Release number REV 07. October, 2015

Display Systems. 1. General. A. Multi-Function Display (MFD) B. Primary Flight Display (PFD)

SKYWELL 5T Quick Start User Guide

The MiniTower GOTO AltAz Mount with GPS and dual Mount set-up #8300

2018 PSO Profile Highlights and Tips. December 18, :00 3:00 PM

HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay

Sunquest Collection Manager (Monitor)

C-887.MC Hexapod Control Unit

EMC Unisphere 360 for VMAX

Troubleshooting Guide

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

EMC Unisphere 360 for VMAX

Bel-Track Manual V /06/2015

SUPPLEMENT AUGUST CITATION PERFORMANCE CALCULATOR (CPCalc) MODEL THRU FM-S51-00 S51-1 U.S.

SUPPLEMENT 3 11 APRIL CITATION PERFORMANCE CALCULATOR (CPCalc) MODEL AND ON 510FM-S3-00 S3-1 U.S.

myidtravel Functional Description

NAIPS Internet Service Authorised NOTAM Originator User Guide Version 3.0. (To be read in addition to NIS User Guide 3.0)

PASSUR Aerospace. Departure Metering Program at Toronto Pearson International Airport. Training Manual

4 REPORTS. The Reports Tab. Nav Log

SERVICE LETTER REVISION

EMC Unisphere 360 for VMAX

Programmable Safety Systems PSS-Range

Wishlist Plug-in USER GUIDE

1224 Splitter and CTO combo, setup instructions using the Panelview HMI

Specialty Cruises. 100% Tally and Strip Cruises

Blue Series Hot Melt Hose with RediFlext II Hanger System

Gas Conversion Kits and Instructions

2/11/2010 7:08 AM. Concur Travel Service Guide Southwest Direct Connect

PublicVue TM Flight Tracking System. Quick-Start Guide

Concur Travel-Frequently Asked Questions

Mobile FliteDeck VFR Release Notes

Navigation Instruction Manual Additional manual to the standard instruction manual

USER GUIDE OPTUS 3G EXECUTIVE EXECUTIVE HOME ZONE HOW TO BOOST YOUR 3G SIGNAL AT HOME YOUR GUIDE TO SETTING UP OPTUS 3G EXECUTIVE HOME ZONE

Specialty Cruises. A. 100% Tally and Strip Cruises

Pelican AMR Gateway User Guide

User manual for awning blind AMZ Z-Wave

Angel Flight Information Database System AFIDS

Configuring a Secure Access etrust SiteMinder Server Instance (NSM Procedure)

Fox World Travel/Concur Documentation Concur FAQ

INSTRUCTIONS FOR USING THIS SAMPLE FLIGHT MANUAL SUPPLEMENT

FliteStar USER S GUIDE

www MK-Electronic de 7. Parts catalog How to use this parts catalog , -220, -230 The following legend is used in the parts catalog:

TILOS & P3 DATA INTERFACE PAUL E HARRIS EASTWOOD HARRIS PTY LTD. 24 July 2007

MEASUREMENT OF ACCELERATION Pre-Lab. Name: Roster#

Setup and Configure the Siteminder Policy Store with Dxmanager

SERVICE LETTER COMMUNICATIONS - LINK CPDLC AND VHF ACARS CONFIGURATION VERIFICATION

Solera Classic Awning OEM INSTALLATION MANUAL

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Special edition paper Development of a Crew Schedule Data Transfer System

Preliminary Staff User s Manual. CASSi The Computerized Aircraft Scheduling System Rev. 1.28a. February 10, 2001

S E L E C T I O N. Abdominal Crunch. User manual

FOREWORD CONTENTS. 1. Preparation and tools required for assembly. 2. Complete parts

Phytclean Guide: How to apply for phytosanitary (special) markets

/ Tool and Equipment Safety Tether System (T.E.S.T.S)

Concur Travel: User Supplied Hotels

This protocol is designed for the isolation of 96 plasmid DNA samples from 1.3ml bacterial cultures. Yield is up to 6µg.

How to Integrate CA SiteMinder with the Barracuda Web Application Firewall

Wishlist Auto Registration Manual

NEWMAR SERVICE SCHOOL

PHY 133 Lab 6 - Conservation of Momentum

GAS STOVE GUARD for natural gas and propane stoves

Flight Evaluation Schedule For GPS IFR Approval Primary Means Enroute, Terminal and Non-Precision Approach

RV10 Weight and Balance

N16422 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS FOR MODEL MD-302 SAM. Standby Attitude Module

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

NHS Professionals System User Guide

Auto Rewind Hose Reel 10M / 20M / 30M Models

Hitachi GigE Camera. Installation Manual. Version 1.6

SUPPLEMENT OCTOBER CITATION PERFORMANCE CALCULATOR (CPCalc) MODEL AND ON REVISION 8 68FM-S17-08

Solera Power Awning OEM INSTALLATION MANUAL

Auper Electronic Controls Inc. Eclipse 4250 IE. Quick User Guide

Antenna Tower Positioning System

AirNav Systems LLC. See aircraft on your computer screen just like on a real radar display

MyFBO Help. Contents TRAINING ONLY

TECHNICAL SUPPORT HOT LINE HOURS: 7:30-3:30

Installation Guide Smart-UPS C 1000/1500 VA 120/230 Vac 2000/3000 VA 230 Vac Rack-Mount 2U

Primrose Awnings - Full Cassette Manual & Electric Instructions

LBH18BPK. Instruction Sheet

Copyright Thomson Financial Limited 2006

ECLIPSE USER MANUAL AMXMAN REV 2. AUTOMETRIX, INC. PH: FX:

Grip Strength. Evaluation copy. Figure 1: Measuring grip strength with the Gas Pressure Sensor

212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad

HelpAndManual_unregistered_evaluation_copy AirLog Pilot Logbook V3

UVACARS User Guide Version 1.0

VULifeFlight.com USER NOTES & GUIDE LIFEFLIGHT APP Medical Center Drive Skyport Helipad VUH Nashville, TN

Transcription:

Quick Start Guide 3500 AquaVent Please read this document carefully before using the AquaVent. High Quality Groundwater and Surface Water Monitoring Instrumentation

Note: For information on using your AquaVent logger with MODBUS or SDI-12 protocols, see separate User Guides. Getting Started 1. Download the software from: www.solinst.com/downloads and install Levelogger Software on your PC. 2. Install the Wellhead batteries. The Wellhead uses four (4) userreplaceable 1.5V AA lithium batteries. 3. Connect the Wellhead and logger to the Vented Cable: Alignment pin in the Wellhead and logger connectors Alignment socket in the Vented Cable connectors Battery Compartment SP Wellhead 10-Pin (SP) Connection Support Hanger Bracket Line up the alignment socket in the Vented Cable connector with the alignment pin in the Wellhead connector. Carefully push the connectors together. Twist the cable connector slightly until you will feel a small click when the properly aligned connection is made. Vented Cable Connector Body Coupling Tighten the stainless steel coupling while holding the stainless steel cable connector body still. Tighten the coupling until it seats. Do not twist the Vented Cable or Wellhead. Follow the same procedure when connecting the logger to the Vented Cable. Note: See page 6 for instructions to install the Support Hanger Bracket, as shown at right. AquaVent Logger AquaVent System Setup - 2 -

AquaVent Quick Start Guide 4. Connect the USB Connector Cable to the 10-Pin (Solinst Protocol) connection on the Wellhead, then plug the USB Connector Cable into your computer. USB Connector Cable Programming AquaVent Loggers Note: Ensure you are using the latest software, and firmware versions for your AquaVent logger and Wellhead. Visit www.solinst.com/downloads, or use the software update feature for help. 1. Start the Levelogger Software, and select the appropriate Com Port for the connected device. 2. In the Datalogger Settings tab, click the Retrieve Settings icon. This will display the current programmed settings for the connected AquaVent. 3. You can now customize the Aquavent Project ID, Locations, sampling regime, and start and stop times. If a number of AquaVent loggers are to be programmed with identical inputs, clicking the Save Default Settings icon will create a template. AquaVent Datalogger Settings Window The Future Start and Future Stop options are ideal for synchronizing the data collection of multiple loggers. Note: Clicking on the embedded in the software will provide you with a short explanation of that feature, e.g. Com Port, Slate Mode, Time Synchronization, etc. Starting and Stopping AquaVent Loggers 1. If desired, enter a Future Start and/or Future Stop time. 2. When the Start icon is selected, all settings are applied to the AquaVent logger and it will start logging at the specified time. 3. To start logging immediately, do not fill in the Future Start field, and click the Start Now icon. Note: When start is selected, a window will pop-up as an alert that the previous data will be erased. 4. To stop the AquaVent immediately, click the Stop Now icon. - 3 -

Downloading and Working with Data 1. Click the Data Control tab to access the Data Control window. This window is laid out in three sections: datalogger settings, tabular data, and graphical data. 2. To download data from a connected logger, select the Download Data from Datalogger icon. There are four options for downloading data: All Data, Append Data, Partial Download, and Recover Previous Log. The data will be presented in tabular and graphical formats. Note: The default directory for downloaded and saved data is: <C:\Program Files\Solinst\Levelogger4_2\Data> Data is saved as an *.xle file. Note To change the default directory for downloaded data, use the Configuration menu at the top of the software window. Select Application Settings and input or navigate to a different folder destination. Click OK. 3. To save data, click the Save Data icon and input the desired name for the saved file. 4. To export the data file for use in other software programs, click the Export icon. The file can be exported as a *.csv or *.xml file. The *.csv and *.xml file formats are supported and can be imported by most spreadsheet and database programs. The data graph can be exported to a *.bmp file or a *.png file by clicking File > Export > Graph. Data Control Window Real Time View Real Time View provides on-screen measurement as data is being recorded by the connected logger. A view rate is set independently of the logging period of the AquaVent and does not interfere with internal logging taking place. To take a reading at any specific time, click and that reading will be added to the displayed data. The data can be exported and saved. Compensate the Data Click the Data Wizard tab to open the Data Wizard window. In this window the Wizard will guide you through Manual Data Adjustments (elevation or height of water conversions) and Parameter Adjustments (units, elevation, density adjustments) on your open data files. Multiple AquaVent data files can be compensated at once. Manual Data Adjustments allow you to use manual water level measurements to adjust your data to depth to water readings. - 4 -

AquaVent Quick Start Guide AquaVent Ranges AquaVent Models are rated to a specific submergence depth (Table 1). The choice of model depends on the accuracy of the level required and the submergence depth. Most important, your selection should be based on the maximum anticipated water level fluctuation. AquaVent Models Submergence Depth Accuracy M5 5 m (16.4 ft.) ± 0.3 cm (0.010 ft.) M10 10 m (32.8 ft.) ± 0.5 cm (0.016 ft.) M20 20 m (65.6 ft.) ± 1 cm (0.032 ft.) Table 1 - AquaVent Ranges Note The AquaVent logger can withstand overpressurization of 2 times the intended range, e.g. a Model M10 can accommodate a fluctuation of 20 meters or 60 feet and still record pressure. However, over-range accuracy is not guaranteed. Measurement Fundamentals AquaVent loggers detect both water (W) and barometric pressure (+B). However, a vent tube to surface allows barometric effects on the pressure sensor to be eliminated (-B). Therefore, AquaVent loggers provide readings of the actual pressure of just water above the pressure sensor zero point (A). A = (W + +B) + (-B) Therefore, A=W A = AquaVent readings W = Water column height +B = Barometric pressure detected by the pressor sensor -B = Barometric pressure applied through the vented cable Note To adjust all readings in your AquaVent data file to depth to water below a well casing (d), record a manual water level measurement using a water level meter. This reading should correspond in data and time with an actual AquaVent recording. Use this as a reference datum in the Manual Data Adjustment option in the Software Data Wizard. Verifying Readings Compare AquaVent readings (A) with a measured depth to water level value (d) (Using a Water Level Meter). The deployment depth of the AquaVent (D), minus the manual depth to water measurement (d), should equal the AquaVent reading: D - d = A - 5 -

AquaVent Field Notes Before Deployment Before deployment, make sure you do the following: Program your AquaVent logger, using Levelogger Software, with the correct project identification, memory mode, sampling regime, time, etc. Note: It is useful to synchronize the times of all AquaVent loggers being used for the same project. Set a future start time in the office, or start the AquaVent logger in the field using Levelogger PC Software and a laptop, or the Solinst Levelogger App & Interface. Determine borehole depth to ensure AquaVent logger does not touch the bottom of the well (avoid submergence in sediment) Record the deployment depth of your AquaVent logger. It is recommended to take a manual water level measurement before installing an AquaVent logger, shortly after installation, periodically during your monitoring interval, and at the end of your measurement period. Use these measurements to verify AquaVent readings, and for data adjustments later on. Ensure you take manual readings as close in time as possible to a scheduled AquaVent reading. Note: The length of the Vented Cable should not be assumed as the deployment depth, as there may be some slack in the cable, especially when using the hanger bracket Use a Solinst Model 101 or 102 Water Level Meter to take a manual depth to water measurement that will be used to verify AquaVent readings Determine the minimum and maximum expected water levels, as AquaVent loggers must remain submerged for the entire monitoring period. Deployment The AquaVent system is designed to be conveniently installed on a 2" well casing (4" using an adaptor). However, other installations are acceptable, if proper precautions and recommendations are followed. The Wellheads have a rating of IP 64 (dust and splash resistant), so should not be submerged at anytime. They can be secured inside an enclosure, however, it must be vented to equalize atmospheric pressure. Do not drop the AquaVent logger into the water, carefully lower it into place. Avoid installing in areas where water hammer or hydraulic jump (very sudden, large increases in pressure) may occur. Be careful not to nick or bend the Vented Cable during installation. Note: For tips, precautions, and more information on installations in different environments and applications, see the latest AquaVent User Guide. After Deployment After deployment, make sure you do the following: Take a manual depth to water measurement after the well has stabilized (approximately 10 minutes)) Take another manual depth to water measurement just before removing the AquaVent logger from the well Support Hanger Bracket Installation - 6 -

AquaVent Quick Start Guide In-Field Communication There are two SP Wellhead Cable options for communicating with AquaVent loggers in the field. The USB Connector Cable allows you to connect to a field laptop for communication using Levelogger Software (see image on Page 1). The App/DataGrabber Connector Cable allows you to connect to a Levelogger App Interface for communication using the Solinst Levelogger App, or to a DataGrabber for downloading data to a USB device. App/DataGrabber Connector Cable DataGrabber Levelogger App Interface LED: Wellhead Connection Status The AquaVent Wellheads have a multicolour LED light which indicates the status and operation of the AquaVent: Fast multicolour cycle 3 times: Wellhead is powering-on Fast 10 cycles alternating blue/green: Wellhead has successfully connected to the PC using the USB Connector Cable Fast 10 cycles alternating blue/red: USB connection has been dropped Flashing yellow: The Wellhead is communicating with the PC Software Note The SPX Wellhead has additional LED definitions related to MODBUS and SDI-12 operation. For information on communication using MODBUS or SDI-12 Protocols, see separate User Guides. Maintenance As with any monitoring project, you should select the proper equipment and determine a maintenance schedule based on the environment specific to your application. To ensure the vent tube remains dry, the AquaVent loggers and Wellheads contain permanent desiccants and hydrophobic membranes at the connections to the Vented Cable - there is no need to replace them. Please see our technical bulletin on Vented Cable Design, Use, and Maintenance for more details. Other maintenance tips include (see the AquaVent User Guide for more details): Replace the o-rings at the Vented Cable connections on the AquaVent logger and the Wellhead. Keep the dust caps on all of the connections, when not in use. Store the AquaVent logger in its case, and the Vented Cable on its spool when not in use. Ensure connections are clean before assembling. Clean the AquaVent logger as required. Replace the Wellhead batteries as required (four user-replaceable 1.5V AA lithium batteries). AquaVent Sampling Rate 8 readings per second 10 days 1 reading per second 3 months 1 reading per minute 8 years Battery Life Estimate - 7 -

Troubleshooting Levelogger PC Software: 1. You must have administrator privileges to install software on a computer. 2. Windows 7, 8, and 10 Operating Systems support Levelogger Software. AquaVent data has been accidentally erased: If the AquaVent has been restarted and the old data has not been saved, select the download option Recover Previous Log. This will download your previous data set. Try the following if your AquaVent is not communicating with Levelogger PC Software, or you are getting a communication error message: 1. Make sure you have installed the batteries correctly: Ensure proper polarity, paying attention to the positive {+} and negative {-} symbols etched in the holder Ensure proper alignment; the spring contacts in the housing should be lined up with the protruding contacts on the bottom of the battery holder 2. Check the Vented Cable connections to the AquaVent logger and Wellhead. Ensure they are lined-up correctly and there is no dirt or debris in the connection. 3. Make sure you are using the correct Wellhead Connector Cable to connect to the PC. You must be using a USB Connector Cable connected to the 10-pin Solinst Protocol connection on the Wellhead. The cable and connection are colour-coded orange. 4. Check that the USB Connector Cable is connected to the same Com Port that is chosen in the upper middle of the Main Window of the Levelogger Software. 5. Check the Com port settings. They should be as follows: Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow control: None (This may have been set to Xon/Xoff change it to None, Select [OK] and back out of this pathway.) 6. Try communicating with another AquaVent logger, Wellhead, Vented Cable or USB Connector Cable. 7. Try using a different computer. 8. If problem persists, contact Solinst. To reset the AquaVent battery indicator, after replacing the Wellhead batteries: Go to the Diagnostic Utility in Levelogger Software, click Run Diagnostics, then click Reset AquaVent Battery Indicator. Note: For diagnostic purposes, you may want to install the end of the Vented Cable with the serial number to the surface connection at the Wellhead. (#112802) June 23, 2016 Printed in Canada Solinst and Levelogger are registered trademarks of Solinst Canada Ltd. AquaVent is a trademark of Solinst Canada Ltd. For further information contact: Solinst Canada Ltd. Fax: +1 (905) 873-1992; (800) 516-9081 Tel: +1 (905) 873-2255; (800) 661-2023 35 Todd Road, Georgetown, Ontario Canada L7G 4R8 Web Site: www.solinst.com E-mail: instruments@solinst.com