SLP. Contents. SLP Ordering Details... 12/2 Technical Data... 12/5 12/1 1SBC R1001

Similar documents
NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

FastLine. Contents. FastLine Description... 14/2 Ordering Details... 14/3 Technical Data... 14/7 14/1 1SBC R1001

Switch Disconnector Fuse, SR A. SlimLine

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

ABB Kabeldon. Laboratory Report. Mechanical test of Service Distribution Cabinets, SDC and SDCM

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Emergency Stop Devices

Surge-Trap Pluggable STPT12 Series kA

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

MINIPOL SYSTEM Hot moulded GRP

Model Number Structure

TECHNICAL INFORMATION

Surge-Trap Pluggable STPT2 Series - 40kA

Standardization of Shore connection Systems

Uninorm. Colour: Black, similar to RAL 9005; special colours on request. Protection class: IP 40 up to IP 65/DIN EN 60529, depending on the design

Safety Interlock Switches

a Nexans company Catalogue 2009

General-purpose Relay

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

Conservatory awning W8 Description

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Product Range. Switches Spur Units Sockets Communication Accessories Other Modules Front Plates & Frames 23-28

General Purpose High Power PCB Relays

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

POSEIDON 4. Part List US-English

3-circuit square RCS750

Part 9 MAINTENANCE MANUAL. Distribution Construction Standards Handbook

S&S POWER SWITCHGEAR. Founded by N S Sethuramon and A R Shanthanakrishnan way back in 1978

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

S36 230V MOTOR COVER

RCS750 3-circuit square track system flexible and multifunctional

NK Multi-stage submersible pumps

Plug-in/solder terminals with LED indicator

Installation and Maintenance Manual

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Molded High-Voltage Bushing Wells

Application Corridors Staircases Entrance areas Restrooms Emergency exits Parking garages Outdoor safety lighting

Squirrel Cage 3-Phase Induction Motor TS21F-II SERIES

MAIN SWITCHES, CONTROL SWITCHES, COMMAND AND SIGNALLING DEVICES

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

SERVICE BULLETIN no. 07/10/2014 Clarification of PR-011 Spring Opening Band position on the packed parachute container for parachutes range PL-70

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

PROFIBUS Cordsets Technical Data

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

Pelican AMR Gateway User Guide

Electronic Temperature Controls

Safety and process lock Knox

General-Use Auto-Tuning HPX-T Series

FIBER OPTIC CLOSURES

Product Guide LED OBSTRUCTION LIGHTS

Cutting and stripping tools

SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

AXICOM COMPOSITE HOLLOW CORE INSULATORS STANDARD TYPES

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

Spare parts list ( ) Spare parts list BR 40/10 C

MILSPEC Choose Your Style

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

DUOTEL PLUS. Installation and User Manual. 2 Port Telephone Exchange Simulator. Issue 1.4

How to operate TBC-553L

Part 5 Low Voltage Underground DISTRIBUTION CONSTRUCTION STANDARDS HANDBOOK

AIXLIGHT PRO RECESSED SPOTLIGHT SYSTEM

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications

O D U L. AEC Illuminazione S.r.l. Zona Industriale di Castelnuovo Subbiano (Ar) Tel. +39.(0) Fax +39.(0)575.

AXELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories. Technical manual

Attachment A - SMA America, LLC - Product List - May 7, 2014

IB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display

Gavita Pro 1650 e LED ML

Table of contents. Power Industry Cabinets


Selection Guide EQUIPMENT FOR OVERHEAD LINES

VDE Torque 1000 V 1000 V. VDE Assortments 587

SHIV Green Energy : SPECIALIST FOR :

Feature. Model comment JG 3NA B L - B - D3

Provides a one stop shop for all your electrically profiling beds frames and a full range of accessories to supplement the functionality of the bed

VDE INSULATED SAFETY TOOLS

BRAGI FUNCTIONAL LIGHT LINE FOR RETAIL, INDUSTRY AND WAREHOUSING

AFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)

Exploded views meat slicer: 800S. DEKO Holland bv B Arnhem The Netherlands

Working under tension. Personal protection equipment.... convincing solutions

SMA America, LLC - Product List - Version 2014 A - February 4, 2014

Data Sheet for Precision Potentiometer

Tradition and innovation

Tip-Over Switches - Non Mercury Contacts

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Transcription:

12 Contents SLP Ordering Details... 12/2 Technical Data... 12/5 12/1

Ordering Details Item Description Type Order code Units Per Weight Designation Package Per Unit SLP SLP 100 100A NHP 138902R0005 0,8 SLP 00 160A NHPL045111R0001 0,88 SLP 1 250A NHPL045211R0001 2,61 SLP 2 400A NHPL045311R0001 4,97 SLP 3 630A NHPL045321R0001 5,36 SLP-K SLP-K 1 250 A for single and double clamps NHP 139740R0001 2,72 SLP-K 2 400 A for single and double clamps NHP 139741R0001 5,1 SLP-K 3 630 A for single and double clamps NHP 139742R0001 5,52 SLP for Busbar system SF 60 SLP-H 00 160A Cable conn. below NHP 139630R0001 1,18 SLP-V 00 160A Cable conn. below NHP 139630R0002 0,85 SLP-H 00 160A Cable conn. above NHP 139630R0003 1,09 SLP-V 00 160A Cable conn. above NHP 139630R0004 0,8 SLP-H 1 250A Cable conn. below NHP 100344R0001 3,4 SLP-H 1 250A Cable conn. above NHP 100344R0002 3,4 SLP 4 Pole SLP 00 4 pole 160A NHP 100844R0001 1,2 SLP K1 4 pole 250A NHP 100799R0001 4 SLP K2 4 pole 400A NHP 100838R0001 7,6 SLP K3 4 pole 630A NHP 100838R0002 8,1 SLP 00 4-pole SLP Variants SLP 00 S 160A w/rail mounting device NHPL045112R0001 1,15 SLP 00 MNS 160A for MNS-adaptor NHPL045119R0001 0,75 SLP 1 MNS 250A for MNS-adaptor NHPL045219R0001 2,4 SLP 00-M611 160A w/fuse surveillance NHPL045131R0001 1,35 SLP 00 MNS-M611 160A w/fuse surveillance NHPL045139R0001 1,2 SLP 1-M611 250A w/fuse surveillance NHPL045231R0001 3,13 SLP 1-MNS-M611 250A w/fuse surveillance NHPL045239R0001 2,9 SLP 2-M611 400A w/fuse surveillance NHPL045331R0001 5,5 SLP 3-M611 630A w/fuse surveillance NHPL045341R0001 5,9 SLP 00-H95 Cable conn. below NHPL045115R0001 1,16 SLP 00-H95-M611 w/ fuse surveillance NHPL045138R0001 1,63 12/2 ABB Building Technologies

Ordering Details 12 Item Description Type Order code Units Per Weight Designation Package Per Unit Front frame Accessories Front frame SLP 100 / 00 NHPL045151R0001 0,04 Front frame SLP 1 NHPL045251R0001 0,06 Front frame SLP 2/3 NHPL045351R0001 0,15 Front frame for INS for 1 pcs SLP 100 / 00 1SEP201431P0001 Front frame for INS for 2 pcs SLP 100 / 00 1SEP201431P0002 Front fixing device complete SLP 100 / 00 NHPL045152R0001 0,3 Front fixing device complete SLP 1 NHPL045252R0001 0,51 Front fixing device complete SLP 2/3 NHPL045352R0001 0,7 Front fixing bracket and front frame SLP 100 / 00 NHP 403634R0001 1 Front fixing bracket and front frame SLP-K 1 NHP 403635R0001 1,2 Front fixing bracket and front frame SLP-K 2/3 NHP 403636R0001 0,03 Rail mounting device SLP 00 NHPL045158R0001 0,25 Front fixing device compl. Cover IP 30 SLP 00 NHP 139528P0001 0,04 Cover IP 30 SLP 1 NHP 139279P0001 0,04 Cover IP 30 SLP-K 1 NHP 139763P0001 0,04 Cover IP 30 SLP-K 2/3 NHP 139764P0001 0,04 Cover IP 30 4 pole SLP 00 4 pole NHP 100991P0001 0,04 Cover IP 30 4 pole SLP K1 4 pole NHP 100993P0001 0,06 Cover IP 30 4 pole SLP K2 4 pole NHP 100992P0001 0,06 Cover IP 30 4 pole SLP K3 4 pole NHP 100992P0001 0,06 Front fixing bracket and front frame Cover with fuse surveillance M611 SLP 00 NHPL045154R0001 1 Cover with fuse surveillance M611 SLP 1 / SLP-K 1 NHPL045254R0001 1,3 Cover with fuse surveillance M611 SLP 2/3 / SLP-K 2/3 NHPL045354R0001 1,5 Auxiliary contact b SLP 00/SLP 1/2/3 NHPL045270R0001 0,01 Auxiliary switch h SLP 00 NHPL045153R0001 0,02 Auxiliary switch h SLP 1 NHPL045253R0001 0,03 Auxiliary switch h SLP 2/3 NHPL045353R0001 0,04 Front fixing SLP 100/00/00 4-pole NHPL045155R0001 0,02 MNS Adaptor SLP 00 GLBS500126R0002 MNS Adaptor SLP 1 GLBS500127R0001 Rail mounting device Cover with fuse surveillance M611 Auxiliary contact b Cover IP 30 Spare parts Cover SLP 00 NHPL045156R0001 0,04 Cover SLP 1 NHPL045256R0001 0,06 Cover SLP 2/3 NHPL045356R0001 0,08 Busbar system SF-60 Busbar carrier 3P 5-10 x 12-30 mm GHV 240849R0001 0,17 Busbar carrier 1P GHV 240849R0003 Cover f/busbar carrier GHV 240849R0004 0,03 Cable conn. module 5-10 x 12-30 mm GHV 240849R0034 0,62 Cover for cable conn. Module GHV 240849R0036 0,15 Cover for SLP H/V 00 NHP 139528P0002 0,05 Cover for busbar 12-30 x 5 mm NHSN320001P0001 0,07 Cover for busbar 12-30 x 10 mm NHSN320001P0002 0,084 Auxiliary contact h ABB Building Technologies 12/3

Ordering Details Item Description Type Order code Units Per Weight Designation Package Per Unit JM, Single Cable clamps JM Single cable 70-150 mm2 SLP-K 1 NHP 403628R0001 0,28 clamps, Al/Cu 120-300 mm2 SLP-K 2 and SLP-K3 NHP 300173R0001 0,6 JM Double cable 2x70-150 mm2 SLP-K 1 NHP 403631R0001 0,39 JM, Double ABB single 16-150 mm2 SLP-K 1 NHP 403627R0001 0,12 ABB single 16-240 mm2 SLP-K 2 and SLP-K 3 NHP 403677R0001 0,24 KP Single cable calmps, SLP-K 2 Al / Cu 95-240 mm2 and SLP-K 3 NHP 403630R0001 0,46 KP Double cable calmps, SLP-K 2 Al / Cu 2x95-240 mm2 and SLP-K 3 NHP 403633R0001 0,85 Cable lug connection, Al/Cu 240 mm2 SLP-K 1 NHP 403625R0001 0,1 Cable lug connection, Al/Cu 300 mm2 SLP-K 2 and SLP-K 3 NHP 403626R0001 0,16 ABB, Single For busbar connection, Al/Cu 35 mm SLP-K 1 NHP 403625R0001 0,1 For busbar connection, Al/Cu 40 mm SLP-K 2 and SLP-K 3 NHP 403626R0001 0,16 KP, Single KP, Double For cable lug connection For busbar connection 12/4 ABB Building Technologies

Technical Data 12 3-pole Type SLP 100 SLP 00 SLP-K1 SLP-K2 SLP-K3 SLP 1 SLP 2 SLP 3 For HRC fuse links acc. to DIN 43620/ IEC 60269-2-1 00 00 1 2 3 Rated operational voltage U e (V) 400 500 690 500 690 500 500 Rated operational current I e (A) 100 160/125 100 250 250 400 630 Rated insulation voltage U i (V) 1000 1000 1000 1000 1000 1000 1000 Rated impulse withstand voltage U imp (V) 8000 8000 8000 8000 8000 8000 800 Fuse protected short circuit making (ka rms ) 50 30/50 50 50 50 50 50 Rated making and breaking capacity AC 22B AC 22B AC 21B AC 22B AC 21B AC 22B AC 22B Rated frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Degree of protection from the front Open IP 10 IP 10 IP 10 IP 20 IP 20 IP 20 IP 20 acc. to IEC 60529 Closed IP 30 IP 30 IP 30 IP 30 IP 30 IP 30 IP 30 4-pole Type SLP 00 SLP-K1 SLP-K2 SLP-K3 For HRC fuse links acc. to DIN 43620/ IEC 60269-2-1 00 1 2 3 Rated operational voltage U e (V) 400 400 400 400 Rated operational current I e (A) 160/125 250 400 630 Rated insulation voltage U i (V) 1000 1000 1000 1000 Rated impulse withstand voltage U imp (V) 8000 8000 8000 8000 Fuse protected short circuit making (ka rms ) 30/50 50 50 50 Rated making and breaking capacity AC 22B AC 22B AC 22B AC 22B Rated frequency (Hz) 50/60 50/60 50/60 50/60 Degree of protection from the front Open IP 10 IP 20 IP 20 IP 20 acc. to IEC 60529 Closed IP 30 IP 30 IP 30 IP 30 Typetested according to IEC 60947-3 Derating factor when mounting switches into cubicles the following derating factors must be considered: No. of apparatus 2 3 4 5 6 9 10 Derating factor 0.9 0.8 0.7 0.6 According to IEC 60439 ABB Building Technologies 12/5