SHELTER CONFIGURATION PROGRAM DECON EXERCISE

Similar documents
Yamhill Fire Protection District

DECONTAMINATION TENTS, SHOWERS, BASINS

Inflatable Tent. Medical, Decontamination, Activity

Pneumatic tents and showers. Immediately ready to use and extensively equipped.

Propane Accessories. Call or Houston, Texas:

WHY FSI? PRODUCTS FOR EMERGENCIES. By FSI North America

HUMANITY TENT Price List Valve

Pneumatic tents and showers. Immediately ready to use and extensively equipped.

READY FOR ANYTHING

ECCOTEMP PRODUCT CATALOG

Emergency Management Portable Water System Set-up and Operations Manual

Individual Decontamination Shelter. Operators Manual

INFLATABLE RESCUE TENTS

PROPANE LANTERNS LIMITED WARRANTY. All propane lanterns carry a

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

Description Price Select The Sojourn 5 x 8.5 Teardrop $13, $13,978.00

The Events Structure Product Guide

18" H x 14" Wx 9" D 1362 in³ Available in MultiCam, O.D., Black, Tan $50.60 $50.60 $50.60 $89.26

ELEVATION MODELS Elevation models weigh up to 20% less than every other Toy-Hauler in their class!

G O L A T A 008 C ALINER 2

Hughes Articulating Rapid Deployment

2016 Custom Phoenix Campers Built for Your Adventurous Needs

The Bubble Blaster sprayer tip. UL listed plug. water hose attachment. easy access to sprayer tips

POP-UP INFLATABLE BESPOKE STRUCTURES

A.C. NELSEN RV WORLD 2013 ICE CASTLE FISH HOUSES CUSTOMER CATALOG Hwy 101 S. Shakopee, MN (952) (888)

LDRP1. Medical Military Facilities Templates. Room. Description: Sheet. 30-Jan-15. Pub Date: Labor & Delivery Room (LDRP1)

Factory Direct made in the U.S.A. Catalog issue 425. Powell. Military supply inc.

ELEVATION MODELS Elevation models weigh up to 20% less than every other Toy-Hauler in their class!

READY FOR YOUR MISSION RIFLE CASES BACKPACKS RANGE BAGS PISTOL CASES

Rainfall Simulator Guidebook

LP Grill and Gas Hose

TENTS, CANOPIES AND TEMPORARY MEMBRANE STRUCTURES

Parkes series caravan. customer guide

FOR SALE Willamette Pass Inn & Chalets Crescent Lake, OR

Buyer s Guide Hose Restraints FAMA BUYER S GUIDE TC041. Hose Restraints. Prepared by the FAMA Body Subcommittee

BY THOR MOTOR COAC H

BY THOR MOTOR COAC H

BRII2/BRAR2. Medical Military Facilities Templates. Room. Description: Sheet. 1-Feb-16. Pub Date: Bedroom, ICU/CCU, Protective Environment (BRII2)

Hughes Articulating Rapid Deployment

BAG COLLECTION

IMAGINE TRAVEL TRAILERS. Imagine Towing Light Without Compromise

GEIGERRIG. Drink it, share it, spray it - with Geigerrig hydration packs you ll never have to stop for a water break.

Instructional Booklet

Travel. Accessories. convenient products that organize your travel needs

Emergency Pneumatics. Medical tents. Product catalogue

Cooking Booth Construction and Location (See Figure 1 and 2 for diagrams):

Emergency Pneumatics. Medical tents. Product catalogue

Real Log Park Model Cabins. Real, Rustic Log Cabins on Wheels!

ORTHOPEDIC, TRAUMA TOURNIQUETS AND CUFFS

Migrate in a Mallard...

A reflection of your personality.

Western Range Camps, LLC So Blackhawk Blvd, Mt Pleasant, Utah ,

Check out our Website to see the Tvan in ACTION


HORSE TRAILERS BUILT FOR YOU WITH THE NEW STANDARD OF EXCELLENCE. (888)

Emergency Pneumatics. Medical tents

PHALANX Wide Area Protection SYSTEMS

RALPH S ARCTIC CAT / YAMAHA MOTORSPORTS WILDERNESS VILLAGE DISPLAY DAY. Saturday, May 22/10 9:00 AM to 6:00 PM

Overview. Options and Upgrades

Traditional Pole Tent Brochure for 2018

OLIVERTRAVELTRAILERS.COM 2018 OLIVER LEGACY ELITE SETTING A NEW STANDARD IN QUALITY TRAVEL TRAILERS

ASNSW NEANN ADK ADVANCED DRUG KIT INFORMATION BOOKLET. PLEASE READ BEFORE USE OR WARRANTY MAY BE VOID

Operating Instructions VETTER Pneumatic Decon Tents

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM WILDLAND HOSELAYS

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

MR274B Kitchen and Bunk House. MR274B Dinette Booth in Lifelong. Pull Out Waste Basket

ABOUT REEVES SHELTER SYSTEMS

SC FF DESIGNED BY CAMPERS FOR CAMPERS LIMITED EDITION. stoneycreekcampers.com.au

PARTS LIST CHARGER 2022 ABLT

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

02 Storage. Roller cabinet. Magnetic tray 25 Modular storage 28 Fixed storage 30. Metal trolley. Plastic box. Aluminium case.

American Surplus & Mfg

Ready for Your Mission

Versatile designs and the same legendary durability at a serious value

OWNER S MANUAL. ezup.com. 13 x 13 (4.0m x 4.0m) 10 x 10 (3.0m x 3.0m) 16 x 16 (5.0m x 5.0m)

CREEK COMPANY PONTOONS

Inflatable tents. Removable Roof. One Pump System. Spare Bladder (long) Valve. Spare Bladder (short) Event Tent 4000

AND. Wet/Dry Vac Direct Import Product Line FOB: Shanghai, China

Adapter, Assy, Union (NSN)

EVENT TENT Price List

Marin County Fire Department. Fire Protection Standard 119. Tents and Awnings

Fabulous Homes International Realty Group Office: Direct Via what s App: / / / Website:

#1 Selling RV In Minnesota

Holiday AirVolution 300

XB SERIES SHELTER MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

A.M. SERIES HYDRATION PACKS

Enjoying the Journey...

Personal Care Quality Workmanship Industry Leading 6 Year Structural Warranty New Interior LED Lighting and Solar Panel Standard on Every Model

WET/DRY VACUUMS. Page No. Commercial Series Wet/Dry Vacuums. Gallon Capacity. Models Industrial Series Wet/Dry Vacuums

PLEASE READ CAREFULLY

Hurricane Preparedness for Community Associations

PREMIUM PAINT SYSTEM

CARAVAN SALON DÜSSELDORF Page 1 of 5

31 BR 33 BR FLOOR PLANS

MANHATTAN PORTAGE PERFECT FOR BIKING

CARAVAN SALON DÜSSELDORF Page 1 of 5

BAGS, PACKS & CASES VALID FROM 1/19/18 TO 2/16/18

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Wildland Progressive Hose Lays Revised


Single Decontamination Shower. Product Manual

Transcription:

DECON EXERCISE

AFTER HURRICANE KATRINA MISSISSIPPI

DECON EXERCISE

Command Center, Sept 11, 2001 Manhattan, NY Site of Flight 93, Sept 11, 2001 Somerset County, PA

(1) BASIC NEED FOR SHELTER A) DECONTAMINATION B) COMMAND POST C) REHAB D) HOSPITAL SURGE E) PATIENT ISOLATION F) COMBINATION OF ABOVE G) OTHER

(2) CHOOSE SHELTER SIZE A) MODEL 150 13 5 Wide X 11 0 Long B) MODEL 216 13 5 Wide X 16 0 Long C) MODEL 284 13 5 Wide X 21 0 Long D) MODEL 311 14 8 Wide X 21 0 Long E) MODEL 400 19 1 Wide X 21 0 Long F) MODEL 860 20 5 Wide X 42 0 Long G) MODEL QUAD 19 4 Wide X 29 3 Long

(3) CHOOSE SHELTER COLOR A) BLUE B) YELLOW C) GREEN D) RED STANDARD ROOF HAS CENTER WHITE STRIP FOR LIGHT E) TAN F) OLIVE DRAB G) WHITE H) BLACK I) COMBINATION

(4) EXTERIOR CONFIGURATION A) LAUNDRY PORTS (DECON) B) CLEAR VINYL WINDOWS ONLY (Do not open) C) CLEAR VINYL WITH ROLL UP COVER D) SCREEN ONLY WITH ROLL UP COVER E) SCREEN WITH ROLL UP CLEAR VINYL AND COVER F) ID PANELS WITH VELCRO G) TEXT REQUIRED FOR ID PANEL

(5) WINDOW LAUNDRY PORT ID PANEL PLACEMENT 15 16 13 14 5 3 1 FRONT 11 9 7 8 6 4 2 12 10 MODEL 860 MODEL 150 MODEL 216 MODELS 284, 311, 400 ENTER

(6) CHOOSE DOOR STYLES Center Zip Only (Standard) Center Zip With Dual Roll-Up (7836) Wide Roll Up 7834 Connector With Dual Roll-Up 7837 Connector With Single Roll-Up 7812 Connector Only

(7) INTERIOR CONFIGURATION (NON-DECON) DIVIDER CURTAIN - CENTER DIVIDER CURTAINS SIDE TO SIDE CLIPS ONLY FOR FUTURE CURTAINS WATER SYSTEM RETAINERS FOR FUTURE DECON ADDITIONAL UTILITY STRAPS ATTACHABLE INSULATION PACKAGE OTHER

(8) INTERIOR CONFIGURATION (DECONTAMINATION) NUMBER OF CORRIDORS NUMBER OF STAGES NUMBER SHOWER HEADS- DECON & RINSE HAND HELD SHOWER NOZZLES CONTAINMENT POOL ELEVATION GRIDS SUMP PUMP SYSTEMS WASTE WATER CONTAINMENT

(9) AIR CONDITIONERS SHELTER HEATERS DECONTAMINATION HOT WATER HEATERS LIGHTING NON AMBULATORY STORAGE OPTIONS

AIR CONDITIONING 120 VAC 13,500 BTU 220 VAC 24,000 BTU 220 VAC 42,500 BTU 220 VAC 60,000 BTU

SHELTER HEATERS Propane Fuel, 70,000 BTU

SHOWER HEADS Quick Connect Shower Head 1.2 GPM With On/Off Valve Quick Connect Hand Held Shower 1.0 GPM With On/Off Valve

Wastewater Containment Sump Pump Wastewater Bladder Roll Out Containment Pool With Elevated Grids

Injector for decon solution or soap.

HOT WATER HEATERS Diesel Fueled 6 to 16 GPM Propane Fueled 5.8 GPM

Shelter Lighting 120 VAC Fluorescent 30 Watt, 25 Cord

NON AMBULATORY SYSTEMS NON AMBULATORY DECON SYSTEM, WITH GLIDERS NON AMBULATORY ROLLER SYSTEM TEMPS BED GURNEY

Shelter and Accessory Storage STORAGE CARTS Drop Down Tray for Shelter Roll Off Additional Accessory Storage

Complete Trailered Systems

Z-SIPs Zumro Shelter In Place System

Z-SIPs Front panel unlocks, opens, and shelter selfdeploys from within Shelter encased within shell, ready to deploy. Pre-positioned onsite. No need to move heavy components. May be inflated by electric blower or compressed air tank.

Z-SIPs

Z-SIPs

Z-SIPs

Z-SIPs Z-SIP Accessories 860 DEPLOY 860 Z-SIP QUAD Z-SIP QUAD DEPLOY Conceptual Site Layout