Similar documents
LPS 20V 24V. COLD START 40A(t width=1030 s measured at 50% I peak) <0.75mA / 240VAC




35W Single Output Switching Power Supply

60W Single Output Switching Power Supply


320W Single Output with PFC Function

60W Single Output Switching Power Supply




240W Single Output with PFC Function


600W with PFC and Parallel Function PSP-600 series


120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection


62.5W Rated output power for convection; 80W with 18CFM min. forced air

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

50W Single Output Switching Power Supply

Jameco SKU Number:

Jameco SKU Number:

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V


60W Single Output LED Power Supply

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

Test Report: EDR-75-12

1000W Single Output Power Supply

Test Report: EPP

1000W Single Output Power Supply

Test Report: EPP

75W Single Output with PFC Function

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

MODEL CEN CEN CEN CEN CEN CEN CEN V 24V 30V 36V 42V

Test Report: APC

Test Report: EPS 15 12

Test Report: IRM-05-05

Test Report: IRM-05-24

Test Report: HB

Test Report: GSM40A18

Test Report: IRM-10-12

Test Report: IRM-20-24

1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.

20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Test Report: LCM 60DA

Test Report: HEP

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Model Number Structure

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Plug-in/solder terminals with LED indicator

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

General-Use Auto-Tuning HPX-T Series

General-purpose Relay

General Purpose High Power PCB Relays

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Feature. Model comment JG 3NA B L - B - D3

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Model Number Structure

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Reliable high-power LED that gives you the design flexibility and performance you need

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) Internal fuse on both L and N lines.

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Table of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

LUXEON Rebel ES. Energy Saving

SPEDESTER Series QUICK REFERENCE GUIDE

Model Crosspoint Matrix

SPECIFICATION FOR LCD MODULE

Features Benefits Key Applications

LUXEON Rebel PLUS Freedom From Binning

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Limit Switches. 6.2 E47 Precision Switches

LUXEON Z LUXEON Z ES. Breakthrough luminance, design flexibility and optical control for Illumination solutions. Introduction. Benefits.

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Emergency Stop Devices

Reliability Data LUXEON K2. Introduction. Index. Reliability Datasheet RD06

CPFE1000Fi-48 EVALUATION DATA TDK-LAMBDA

TRUMPF TRUMATIC L 3050

HEATER POWER CONTROLLER

Transcription:

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner.

Declaration of RoHS Conformity To minimize the environmental impact and take more responsibility to the earth we live, MEAN WELL hereby confirms that the following product series comply with Directive 2002/95/EC of the European arliament - RoHS (Restriction of Hazardous Substances). Content of Compliance Lead Mercury Cadmium Hexavalent Chrome (Cr +6 ) BBs BDEs <0.1 % by weight (1000 ppm) <0.1 % by weight (1000 ppm) <0.01 % by weight (100 ppm) <0.1 % by weight (1000 ppm) <0.1 % by weight (1000 ppm) <0.1 % by weight (1000 ppm) roduct Series lease refer to the attached list for details. Delivery The actual delivery date for RoHS compliance products will depend on our inventory status. lease contact our sales representatives for details. How to Recognize The serial number on each SU originally was Cxxxxxxxxx and right now will be changed to Rxxxxxxxxx or Exxxxxxxxx (or add R for serial number that only specify the production weeks) for RoHS compliance products for the ease of identification. Jerry Lin / resident MEAN WELL Enterprises Co., Ltd.

roduct Family G3 G2 FC AD CL/L DIN Modular arallel Open Frame Charger Adaptor C/IC ower DC/DC Converter Inverter ower Cord Series RS-25/35/50/75/100/150, RD-35/50/65/85/125, RID-50/65/85/125, RT-50/65/85/125, RQ-50/65/85/125 S-25/40/60/100F/150/240, T-40, D/ID/T/IT/Q/IQ-60, D/T/Q-120, SC-150 S-75/100/150/200/320/480/500/750, US-225/350, T-75/100/150, Q-100/150/200/320/375 ADS-55/155, AD-55/155, ADD-55/155 CLG-60/100, LN-30/60/100 MDR-20/40/60, DR-30/45/60/75/100/120, DRH-120, DR-240/480/480S, DRT-240/480/960, DR-RDN20, DR-US40 M-450/650/1K0, MS-75/150/300, MD-100 S-500/600/1000/1500, RS-1000/1500, RC-1000, RC-1U NFM-05/10/15/20, M-05/10/15/20, S/D-25, S-35, S/D/T-45, S/D/T-65, RD/RT-65, D-110, Q-100, Q-100, S/T-125, LS-50/75/100, L-100/150, AS-150, S-200, ID-250, MS-30, MS/MD/MT-45, RS/RD/RT-60, MS/MD/MT-65, RS/RD/RT-75, MS/MD/MT/MQ-120, MS/MD/MT/MQ-200 GC-30, A/B/S-120, ESC/ES-120, ESC/ES-240, B-300/360 GS-06/15/18/25, ES-18/25, 25, 30, 40, 50, 66, U65S, MES-30/50, ATX-100, AS-120 Y-350J, IC-200/250/300 SD-25/50/100/150/200/350, SDM30, ASD10H/15H, NSD10/15, SBT, SFT, DET, SRS, SUS, SR, SU, SCW, SLW, SKE SKA, DCW, DLW, DKE, DKA, TKA TN/TS-1500, A301/A302 Y** + YC** ** For other products not listed above, please contact our sales representatives for availability 2007.04 update

100W Single Output Switching ower Supply LN-100 s e ries SECIFICATION MODEL LN-100-12 LN-100-15 LN-100-20 LN-100-24 LN-100-27 LN-100-36 LN-100-48 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER VOLTAGE ADJ. RANGE CURRENT ADJ. RANGE LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD U TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE OWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER CURRENT OVER VOLTAGE OVER TEMERATURE WORKING TEM. WORKING HUMIDITY SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE Note.6 5A 5A 4.8A 4A 3.55A 2.65A 2A Note.6 0 ~ 5A 0 ~ 5A 0 ~ 4.8A 0 ~ 4A 0 ~ 3.55A 0 ~ 2.65A 0 ~ 2A Note.6 60W 75W 96W 96W 95.85W 95.4W 96W Note.5 STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION Note.4 12V 15V 20V 24V 27V 36V 48V RILE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE TOLERANCE Note.3 0% ~ -15% 3% ~ -25% 3.0% 1.0% 2.0% 1200ms, 80ms/230VAC 60ms/230VAC 30ms/115VAC at full load 90 ~ 264VAC 47 ~ 63Hz F>0.95/230VAC 3.0% 83% 85% 3.0% 1200ms, 80ms/115VAC at full load F>0.98/115VAC at full load 87% EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level, criteria A MTBF 303.1Khrs min. MIL-HDBK-217F (25 ) DIMENSION 200*70.5*35mm (L*W*H) ACKING 0.52Kg; 20pcs/11.4Kg/0.76CUFT 3.0% 87% 12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45A/230VAC 20V ~ 48V:1.1A/115VAC 0.55A/230VAC COLD START 40A/230VAC 0.5mA / 240VAC 95 ~ 100% rotection type : Constant current limiting, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 29 ~ 36V 39 ~ 48V 52 ~ 64V rotection type : Shut down and latch off o/p voltage, re-power on to recover 90 10 (RTH2) -30 ~ +50 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +80, 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes 3.0% UL1310 Class 2, TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V),I64 approved I/-O/:4.25KVDC I/-O/:100M Ohms/500VDC rotection type : Shut down o/p voltage, re-power on to recover EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 87% I64 2.0% 87% 2.0% 87% File Name:LN-100-SEC 2007-05-16

100W Single Output Switching ower Supply LN-100 s e ries Mechanical Specification 6.26 200 Case No.955A Unit:mm AC/L(Brown) AC/N(Blue) FG (Greed/Yellow) 310 10 18AWG 3C 22.84 AC IN 2-R2.5 70.5 DC OUT 22.84 310 10 18AWG 2C +V(Red) -V(Black) 6.26 35 Block Diagram Fosc : 100KHz I/ EMI FILTER & RECTIFIERS FC CIRCUIT OWER SWITCH- ING RECTIFIERS & FILTER O.L.. +V -V FG FC CONTROL O.L.. WM & FC CONTROL DETECTION CIRCUIT O.V.. OL Characteristics 100 VO (%) 50 (max.) 0 50 95 IO(%) (Vo Io<100VA) Derating Curve 100 80 60 Static Characteristics 100 90 80 70 Ta=25 LOAD (%) 40 20 LOAD (%) 60 50 40-30 -15-5 0 15 30 40 50 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMERATURE ( ) INUT VOLTAGE (V) 60Hz File Name:LN-100-SEC 2007-05-16

100W Single Output Switching ower Supply LN-100 series MODEL:LN-100-24 OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 150 mvp-p (Max ) I/: 230VAC O/: 95% LOAD V1: 16 mvp-p (Max ) 2 OUTUT CURRENT ADJUST RANGE CH1: 20.4V~24 V I/: 230 VAC I/: 115 VAC 19.36V~ 19.36V~ 24.58 24.58 V/ 230 VAC V/ 115 VAC 3 OUTUT CURRENT ADJUST RANGE CH1: 4.12 A~3 A I/: 230 VAC I/: 115 VAC 2.9 2.9 A~ A~ 5.08 5.1 A/ 230 VAC A/ 115 VAC 4 OUTUT VOLTAGE TOLERANCE V1: 3 %~ -3 % (Max) I/: 100 VAC / 264 VAC O/: 95% LOAD / MIN LOAD V1: 1.6 %~ -1.6 % 5 LINE REGULATION V1: 1 %~ -1 % (Max) I/: 100VAC ~ 264 VAC O/: 95% LOAD V1: 0.03 %~ -0.03 % 6 LOAD REGULATION V1: 2 %~ -2 % (Max) I/: 230 VAC O/: 95% LOAD ~MIN LOAD V1: 0.18 %~ -0.18 % 7 SET U TIME 8 RISE TIME 9 HOLD U TIME 230VAC: 1200 ms (Max) I/: 230 VAC 230VAC/ 828 ms 115 VAC: 1200 ms (Max) I/: 115 VAC 115VAC/ 828 ms O/: 95% LOAD 230VAC: 80 ms (Max) I/: 230 VAC 230VAC/ 6 ms 115VAC: 80 ms (Max) I/: 115 VAC 115VAC/ 6 ms O/: 95% LOAD 230VAC: 60 ms (TY) I/: 230 VAC 230VAC/ 111 ms 115VAC: 30 ms (TY) I/: 115 VAC O/: 95% LOAD 10 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC O/: 95% LOAD 11 DYNAMIC LOAD V1: 2400 mvp-p I/: 230 VAC O/: 95% LOAD /Min LOAD 90%DUTY/1KHZ 115VAC/ 36 ms TEST: <5 % 930 mvp-p Model: LN-100-24 Test Report 1 / 5

100W Single Output Switching ower Supply LN-100 series INUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 90VAC~264 VAC I/:TESTING O/: 95% LOAD I/: LOW-LINE-3V= 87V HIGH-LINE+15%=300 V O/: 95% LOAD /MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF NO DAMAGE ) TEST: OK 52V~264V 2 INUT FREQUENCY RANGE 47HZ ~63 HZ 3 OWER FACTOR NO DAMAGE OSC I/: 90 VAC ~ 264 VAC O/: 95% LOAD ~MIN LOAD TEST: OK 0.95 / 230 VAC(TY) I/: 230 VAC F= 0.976 / 230 VAC 0.98 / 115 VAC(TY) I/: 115 VAC O/: 95% LOAD 4 EFFICIENCY 87% (TY) I/: 230 VAC 5 INUT CURRENT O/: 95% LOAD F= 0.989 / 115 VAC 230V/ 0.55 A (TY) I/: 230 VAC I = 0.46 A/ 230 VAC 115V/ 1.1 A (TY) I/: 115 VAC O/: 95% LOAD 90 % I = 0.89 A/ 115 VAC 6 INRUSH CURRENT 230V/ 40 A (TY) I/: 230 VAC I = 30 A/ 230 VAC COLD START O/: 95% LOAD 7 LEAKAGE CURRENT < 0.5 ma / 240 VAC I/: 264 VAC O/:Min LOAD L-FG: 0.34 ma N-FG: 0.34 ma ROTECTION FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 95 %~ 100 % I/: 230 VAC I/: 115 VAC O/:TESTING 98.2 %/ 230 VAC 99 %/ 115 VAC Constant Current Limiting See SEC NOTE 4 2 OVER VOLTAGE ROTECTION CH1: 27V~ 34 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 3 OVER TEMERATURE ROTECTION SEC: I/: 230 VAC RTH2: 90 + 10 O.T.. O/: 95% LOAD NO DAMAGE 31.3 V/ 230 VAC 31.3 V/ 115 VAC Shunt down Re- power ON O.T.. Active Shunt down Re-power ON 4 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR NO DAMAGE I/: 264 VAC O/: 95% LOAD NO DAMAGE Hiccup Mode or Constant Current Limiting Model: LN-100-24 Test Report 2 / 5

100W Single Output Switching ower Supply LN-100 series ENVIRONMENT TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL: LN-100-24 1. ROOM AMBIENT BURN-IN:2 HRS I/: 230VAC O/: 95% LOAD Ta= 30.1 2. HIGH AMBIENT BURN-IN:62 HRS I/: 230VAC O/: 95% LOAD Ta= 45.4 NO osition /N ROOM AMBIENT Ta= 30.1 HIGH AMBIENT Ta= 45.4 1 BD1 US4KB80 4A/800V SHI 74.3 87.3 2 LF2 TR-689 67.0 79.6 3 L2 COIL TF-1356 LS 82.7 94.7 4 L1 COIL TR-623 75.5 88.3 5 Q2 2SK3683 19A/500V FUJI 83.9 96.8 6 D1 MUR460 4A/600V VIS 94.0 107.5 7 C5 150U/400V NCC 105 KMG 86.4 99.1 8 C42 47U/63V RUB 105 YXF 83.9 96.3 9 Q1 SA11N65C3 11A/820V INF 91.4 104.4 10 D2 IN4007 1A/1KV LT 122.9 136.9 11 T1 COIL TF-1472 LS 84.6 107.8 12 U2 TEA1552/N1 H 87.5 100.1 13 U1 TDA4863 INF 78.6 89.5 14 RTH2 200KΩ +5% (90 + 10 ) 81.3 94.1 15 Q100 IRF3415 150V/43A IR 79.1 92.7 16 C105 680U/35V NCC 105 KY 88.0 101.2 17 內環溫 T1 與 C5 中間 86.6 99.7 18 CASE CASE 上方 59.6 74.7 2 OVER LOAD BURN-IN TEST NO DAMAGE 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 VAC O/: 100 % LOAD I/: 230 VAC O/: 95 % LOAD Ta= -30 TEST:OK TEST:OK 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/: 272 VAC O/: 95% LOAD Ta= 50 NO DAMAGE HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/: 230 VAC O/:95% LOAD 6 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) TEST:OK + 0.01 %(0~50 ) TEST:OK Model: LN-100-24 Test Report 3 / 5

100W Single Output Switching ower Supply LN-100 series SAFETY TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 4.25 KVDC/min I/-O/: 5.1KVDC/min I/-O/: 0.007 ma NO DAMAGE 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-O/: 500 VDC I/-O/: 1.3 GΩ NO DAMAGE 3 AROVAL TUV: Certificate NO :R50091288 UL: File NO :E307078 E.M.C TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A CLASS C 2 CONDUCTION EN55022 EN55015 CLASS B 3 RADIATION EN55022 EN55015 CLASS B 4 E.S.D EN61000-4-2 LIGHT INDUSTRY AIR:8KV / Contact:4KV I/: 230 VAC/50HZ O/: 95% LOAD I/: 230 VAC (50HZ) O/: 95% LOAD /50% LOAD I/: 230 VAC (50HZ) O/: 95% LOAD I/: 230 VAC/50HZ O/: 95% LOAD ASS ASS Test by certified Lab ASS Test by certified Lab CRITERIA A 5 E.F.T EN61000-4-4 LIGHT INDUSTRY INUT: 1KV I/: 230 VAC/50HZ O/: 95% LOAD CRITERIA A 6 SURGE IEC61000-4-5 LIGHT INDUSTRY L-N :1KV L,N-E:2KV I/: 230 VAC/50HZ O/: 95% LOAD CRITERIA A 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LIFE CYCLE SUOSE C105 IS THE MOST CRITICAL COMONENT I/: 230VAC O/: 95% LOAD Ta= 25 LIFE TIME= 50930 HRS I/: 230VAC O/: 95% LOAD Ta= 40 LIFE TIME= 20790 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 303.1K HRS Model: LN-100-24 Test Report 4 / 5

100W Single Output Switching ower Supply LN-100 series COMONENT STRESS TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage Q1 Rated SA11N65C3 : 650V 2 Diode eak Voltage Q100 Rated IRF3415 : 43A 150V 3 Clamp Diode eak Voltage D2 Rated IN4007 : 1KV 1A 11 A I/:High-Line +3V = 267 V O/: (1) 95% LOAD Turn on (2) Output Short I/:High-Line +3V = 267 V O/: (1) 95% LOAD Turn on (2)Output Short I/:High-Line +3V = 267 V O/: (1) Dynamic Load 90%Duty/1KHz (1) 564 V (2) 500 V (1) 120 V (2) 103 V (1) 510 V 4 Input Capacitor Voltage C5 Rated : 150 u / 400V/ 105 I/:High-Line +3V = 267 V O/: (1) 95% LOAD Turn on /Off (2) Min load Turn on /Off (3) 95% /Min load Change (1) 384 V (2) 384 V (3) 384 V 5 Control IC Voltage Test U2 Rated TEA1552 : 20V I/:High-Line +3V = 267 V O/: (1) 95% LOAD Turn on /Off (2) Min load Turn on /Off (3) 95% /Min load Change (1) 17.8 V (2) 17.7 V (3) 17.8 V DATE SAMLE TEST RESULT TESTER AROVAL 2006/7/4 RD SAMLE ASS VINCENT TSENG MAX LIN 2006/8/24 2006/11/15 2007/1/11 RODUCT SAMLE W0607C06 RODUCT SAMLE W0611A21 RODUCT SAMLE W0612C36 ASS VINCENT TSENG MAX LIN ASS VINCENT TSENG MAX LIN ASS VINCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: LN-100-24 Test Report 5 / 5