Multi-rate 10-Gigabit DWDM 40km XFP Transceiver with Digital Diagnostics

Similar documents
10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Model Crosspoint Matrix

SFP optical plug-in modules

Reliable high-power LED that gives you the design flexibility and performance you need

General-Use Auto-Tuning HPX-T Series

Table of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved.

SPECIFICATION FOR LCD MODULE

SPEDESTER Series QUICK REFERENCE GUIDE

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Feature. Model comment JG 3NA B L - B - D3

Hiway Gateway Specification and Technical Data

Type CGS High-Cap Screw Terminal Aluminum Electrolytic Capacitor

LUXEON Rebel ES. Energy Saving

Plug-in/solder terminals with LED indicator

LUXEON Rebel. Illumination Portfolio. ANSI Binned with Minimum CRI

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

Model Number Structure

Product Specification

General-purpose Relay

Programmable Safety Systems PSS-Range

LUXEON Rebel PLUS Freedom From Binning

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

INSTRUCTIONS FOR USING THIS SAMPLE FLIGHT MANUAL SUPPLEMENT

Cover...0. Page #...0 TOC Index.0. Inside Back Cover..0. Outside Back Cover 0

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

ADS-B Rule and Installation Guidance

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Engineering Design Assurance Test Report ( S )

UM1868. The BlueNRG and BlueNRG-MS information register (IFR) User manual. Introduction

SerDes and its Role in Future Designs

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

ECLIPSE 500. Aircraft Overview. Do Not Use For Flight

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

HEATER POWER CONTROLLER

General Purpose High Power PCB Relays

LUXEON Z LUXEON Z ES. Breakthrough luminance, design flexibility and optical control for Illumination solutions. Introduction. Benefits.

ADVANCED SURVEILLANCE IN ONE INTEGRATED PACKAGE

Table of Contents. How long do the batteries last?

DUAL COLOR, LOW-PROFILE

SWL Series VALVE REGULATED LEAD-ACID BATTERIES SWL

Technical Standard Order

Garmin GNC 420 GPS Navigator with VHF COM

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

Wrapper Instruction Register (WIR) Specifications

A. Introduction Title: Power System Stabilizer (PSS) 2. Number: VAR 501 WECC

High flux and efficacy on industry s most widely used color platform

DELIVERING OPTICAL SOLUTIONS EMPOWERING COMMUNICATIONS

Jameco SKU Number:

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

VAR-501-WECC-3 Power System Stabilizer. A. Introduction

Emergency Stop Devices

Electrical Specifications. Dimensions (inches)

Electrical Specifications. Dimensions (inches)

Features Benefits Key Applications

Part 171. Aeronautical Telecommunication Services - Operation and Certification. CAA Consolidation. 10 March 2017

Color Line. High flux and efficacy on industry s most widely used color LED platform

First Review Meeting of AFI VSAT Network Managers (AFI VSAT Review/1) (Dakar, Senegal, 3 to 5 October 2011) SUMMARY

Overview: Cisco 7304 Router Carrier Cards

Subject: Request for additional information regarding FCC ID: IHDT6EE1 (Portable PCS GSM Transceiver with Embedded Bluetooth)

ROTORCROSS AUSTRALIA RACE RULES. Aircraft Rules. Model Specification limits: (maximums unless specified) 330mm (motor to motor diagonal)

212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad

12 16 MATRIX LED DRIVER

Applicable to the following airplanes equipped with a Cessna Factory Installed Honeywell KT 76C Transponder.

EC BRUSHLESS MOTOR APPLICATIONS

skybeacon TM STC Instructions for Continued Airworthiness and Maintenance Manual

Media facade RGB LED lighting solution. Sustainable architectural LED lighting systems

WITH DIRECT RESPONSE ELECTRONICS

12x12 MATRIX LED DRIVER

LED-Displays. WIBOND Series Products

DATA MANAGEMENT & CONNECTED SOLUTIONS

DUWC1441 Designer. cabinet, and black interior.

Capacity 24 bottles Six shelves cradle bottles horizontally to keep corks moist o Shelves are coated to reduce vibration

Compressed Air Breathing Apparatus

Office of Aviation Enforcement and Proceedings

Nordic ID HH53 User Guide Version 1.0 NORDIC ID HH53 USER GUIDE

Smart-UPS Installation Guide 750/1000/1500/2200/3000 VA 120/230 Vac 500 VA 100 Vac Tower Important Safety Messages

SMV512K32-DB1F0E 16MB SRAM Datasheet

REFRIGERATION. Standard Features & Accessories. Model Options. Undercounter/Freestanding 24 W. Dual Zone Wine Cellar

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

Test Report: HEP

B 270 Superwite D Requirements deviating from these specifications must be defined in writing in a customer agreement.

REFRIGERATION. Standard Features & Accessories. Model Options. Undercounter/Freestanding 24 W. Wine Cellar

Application Corridors Staircases Entrance areas Restrooms Emergency exits Parking garages Outdoor safety lighting

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

Display Systems. 1. General. A. Multi-Function Display (MFD) B. Primary Flight Display (PFD)

GOVERNMENT OF INDIA OFFICE OF DIRECTOR GENERAL OF CIVIL AVIATION

SUNNY TRIPOWER CORE1-US

EHM Pilot Guide for P&WC's JT15D, PW300, PW500 & PW600 Engines

CFIT-Procedure Design Considerations. Use of VNAV on Conventional. Non-Precision Approach Procedures

AIRCRAFT SERVICE CHANGE

10G - PON. By Mark Pflum RVW, Inc.

P310 VTOL UAV Operation Manual

LUXEON Rebel and LUXEON Rebel ES Color Portfolio

Avionics Qualification Test Supporting Equipment

STATUTORY INSTRUMENTS. S.I. No. 855 of 2004 IRISH AVIATION AUTHORITY (AIR TRAFFIC SERVICE SYSTEMS) ORDER, 2004

Reliability Data LUXEON K2. Introduction. Index. Reliability Datasheet RD06

What is the best way to conserve groundwater? Make your own! With the AquaBoy home/business or commercial units.

Transcription:

Multi-rate 10-Gigabit DWDM 40km XFP Transceiver with Digital Diagnostics TXD3XGGIx000xxG Pb Product Description The TXD3XGGIx000xxG DWDM XFP multi-rate fiber optic transceivers with digital diagnostics monitoring functionality provide a quick and reliable interface for 40km 10Gbps DWDM applications. The diagnostic functions, alarm and warning features as described in the XFP Multi- Source Agreement (MSA) are provided via standard I C serial interface. The transceivers are compliant with the XFP Multi-Source Agreement and are designed to support SONET/SDH, 10G Ethernet, and 10G Fiber Channel data rates from 9.95Gb/s to 11.09Gb/s. Each transceiver utilizes an electro-absorption modulator integrated laser with an operating wavelength in full compliance with 100GHz (0.8nm) spacing per the -grid. The transceivers satisfy Class I Laser Safety requirements in accordance with the U.S. FDA/CDRH and international IEC- 6085 standards. The transceivers connect to standard 30-pad XFP connectors for hot plug capability. This allows the system designer to make configuration changes or maintenance by simply plugging in different types of transceivers without removing the power supply from the host system. The transmitter and receiver DATA interfaces are AC coupled Current Mode Logic (CML). L-TTL Transmitter Disable control input and Loss of Signal output interfaces are also provided. The transceivers operate from +3.3 and +5.0 power supplies over an operating case temperature range of -5 C to +70 C (Commercial), -5 C to +85 C (Extended), or -40 C to +85 C (Industrial). Features Lead Free Design & Fully RoHS Compliant Compliant with XFP MSA Compliant with OC-19/STM-64 Compliant with -T G.709 Support DWDM 10G Ethernet Applications Support 10G Fiber Channel Applications Digital Diagnostics Monitoring Temperature-stabilized EML Transmitter Low Power Consumption Wide Case Range Transmission up to 40km Absolute Maximum Ratings Parameter Symbol Minimum Maximum Units Storage Temperature T ST - 40 + 85 C Commercial - 5 + 70 Operating Case Temperature 1 Extended T OP - 5 + 85 C Industrial - 40 + 85 Supply oltage CC 3-0. + 3.6 CC 5-0. + 6.0 Operating Relative Humidity RH 0 85 % Input oltage IN 0 CC 1 Case temperature is measured on top side of XFP module. Non condensing

Transmitter Performance Characteristics (Over Operating Case Temperature Range) Parameter Symbol Minimum Typical Maximum Units Operating Data Rate B 9.95-11.09 Gb/s Average Optical Output Power (50% duty cycle) P O - 1.0 - + 3.0 dbm Transmitter OFF Power P OFF - - - 45.0 dbm Extinction Ratio @ 9.95Gb/s to 10.7Gb/s ER 8. - - db 1 λ C See Ordering Information Table nm Spectral Width (-0dB) Δλ0 - - 1.0 nm Side Mode Suppression Ratio SMSR 30 - - db Relative Intensity Noise RIN - - - 130 db/hz Reflectance Tolerance ref T - - - 7 db 0 khz 80 MHz JG Jitter Generation 3 0K - - 0.3 UI pp 4 MHz 80 MHz JG 4M - - 0.1 UI pp @ 9.95Gb/s (10-1 BER) - -.0 Dispersion Penalty 4 DP db @ 11.09Gb/s (10-4 BER) - -.5 Optical Output Eye Compliant with GR53-CORE, IEEE 803.3ae, and -T G.959 1 BOL: +/-0.05nm from grid. EOL: +/-0.1nm from grid. Measured with OSA and 0.1nm resolution bandwidth. 3 Jitter generation is compliant with GR-53 and G.851. Receiver Performance Characteristics (Over Operating Case Temperature Range) Parameter Symbol Minimum Typical Maximum Units Operating Data Rate B 9.95-11.09 Gb/s of Operation λ 160-1570 nm Receiver Sensitivity @ 9.95Gb/s (10-1 BER) Pmin - - - 16.0 @ 11.09Gb/s (10-4 BER) - - - 19.0 Maximum Input Power P MAX + 0.5 - - dbm LOS Thresholds Increasing Light Input P los+ - - - 16.0 Decreasing Light Input P los- - 8.0 - - dbm LOS Hysteresis - 0.5 - - db Receiver Reflectance - - - - 7 db dbm Laser Safety: All transceivers are Class 1 Laser products per FDA/CDRH and IEC-6085 standards. They must be operated under specified operating conditions. Oplink Communications, LLC. This product complies with 1 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements Oplink Communications, LLC

Electrical Interface (Over Operating Case Temperature Range) Parameter Symbol Minimum Typical Maximum Units Differential Impedance Z d - 100 - Ω Differential Input oltage Swing pp, diff_in 10-80 m Differential Output oltage Swing pp, diff_out 340 550 850 m Output Rise/Fall Time (0 to 80%) T r /T f 4 - - ps TX_Dis, P_Down/RST IL - 0.3-0.8 IH.0 - CC + 0.3 XFP Interrupt, Mod_NR, RX_LOS OL 0-0.4 OH host_ CC - 0.5 - host_ CC + 0.3 Electrical Power Supply Characteristics (Over Operating Case Temperature Range) Parameter Symbol Minimum Typical Maximum Units Power Supply oltage CC 3 3.13 3.3 3.47 CC 5 4.75 5.0 5.5 Supply Current I CC 3 - - 750 I CC 5 - - 500 ma Power Dissipation PW - - 3.5 W P_Down Power Dissipation PDW - - 1.5 W XFP Transceiver Electrical Pad Layout Host Board Connector Pad Layout 1 3 4 5 6 7 8 9 10 11 1 13 14 15 EE 5 Mod_DeSel Interrupt TX_Dis CC 5 CC 3 CC 3 SCL SDA Mod_Abs Mod_NR RX_LOS Bottom of XFP Board (as viewed thru top of board) Toward Bezel 1 3 4 5 6 7 8 9 10 11 1 13 14 15 30 9 TD+ 8 TD- 7 6 5 RefCLK- 4 RefCLK+ 3 CC 1 TP_Down/RS 0 CC 19 18 RD+ 17 RD- 16 Top of XFP Board TD+ 5 EE TD- Mod_DeSel Interrupt TX_Dis RefCLK- cc5 RefCLK+ cc3 cc cc3 P_Down/RST SCL cc SDA Mod_Abs RD+ Mod_NR RD- RX_LOS 30 9 8 7 6 5 4 3 1 0 19 18 17 16 Toward ASIC Oplink Communications, LLC 3

Module Pin Description Pin Logic Symbol Description 1 - Module Ground - EE 5 Optional -5. Power Supply (Not Required) 3 LTTL-I Mod_DeSel Module De-select; When held low allows module to respond to -wire serial interface 4 LTTL-O Interrupt Interrupt; Indicates presence of an important condition which can be read over the -wire serial Interface 5 LTTL-I TX_Dis Transmitter Disable; Turns off transmitter laser output 6 - CC 5 +5 Power Supply 7 - Module Ground 8 - CC 3 +3.3 Power Supply 9 - CC 3 +3.3 Power Supply 10 LTTL-I/O SCL -Wire Serial Interface Clock 11 LTTL-I/O SDA -Wire Serial Interface Data Line 1 LTTL-O Mod_Abs Indicates Module is not present. Grounded in the Module 13 LTTL-O Mod_NR Module Not Ready; Indicating Module Operational Fault 14 LTTL-O RX_LOS Receiver Loss Of Signal Indicator 15 - Module Ground 16 - Module Ground 17 CML-O RD- Receiver Inverted Data Output 18 CML-O RD+ Receiver Non-Inverted Data Output 19 - Module Ground 0 - CC Nor Used 1 LTTL-I P_Down/RST - CC Not Used 3 - Module Ground Power down; When high, requires the module to limit power consumption to 1.5W or below. -Wire serial interface must be functional in the low power mode. Reset; The falling edge initiates a complete reset of the module including the -wire serial interface, equivalent to a power cycle. 4 PECL-I RefCLK+ Clock Non-Inverted Input (Not Required) 5 PECL-I RefCLK- Clock Inverted Input (Not Required) 6 - Module Ground 7 - Module Ground 8 CML-I TD- Transmitter Inverted Data Input 9 CML-I TD+ Transmitter Non-Inverted Data Input 30 - Module Ground Oplink Communications, LLC 4

Host Board Termination & Coupling TD+ 50Ω line CML INPUTS TD- 50Ω line RD+ 50Ω line 1µH coil or ferrite inductor +3.3 8, 9 + 0.1 10 0.1 XFP CML OUTPUTS RD- 50Ω line ASIC/ SerDes +5.0 1µH coil or ferrite inductor + 0.1 10 0.1 6 SCL, SDA, +3.3 +3.3 R +3.3 R Mod_Abs, Mod_NR, R Interrupt, RX_LOS R: 4.7 to 10kΩ All caps are in units of µf Application Notes Electrical Interface: All signal interfaces are compliant with the XFP MSA specification. The high speed DATA interface is differential AC-coupled internally and can be directly connected to a 3.3 SERDES IC. RX_LOS: The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic HIGH when an insufficient photocurrent is produced. TX_Dis: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled. (less than -45dBm). P_Down: The Power Down Function pin, when held High by the host, places the module in the standby (Low Power) mode with a maximum power dissipation of 1.5W. This protects hosts which are not capable of cooling higher power modules which may be accidentally inserted. The module s -wire serial interface and all laser safety functions must be fully functional in this low power mode. During P_Down, the module shall still support the completion of reset Interrupt, as well as maintain functionality of the variable power supply. Mod_NR: The Mod_NR is an output pin that when High, indicates that the module has detected a condition that renders transmitter and or receiver data invalid, shall consist of logical OR of the following signals: Transmit Signal Conditioner Loss of Lock Transmitter Laser Fault Receiver Signal Conditioner Loss of Lock Other conditions deemed valuable to the detection of fault may be added to the Mod_NR. The Mod_NR output pin is an open collector and must be pulled to Host_cc on the host board. P_Down/RST: The negative edge of Reset Function signal initiates a complete module reset. Module Behavior During P_Down and RST: During execution of a reset (t_init) or while held in Power Down mode, a module may be unable to determine the correct value for Mod_NR and RX_LOS. These outputs as well as all interrupt related flags, except completion of Reset flag, shall be disregarded by the host. When the module completes a Reset and is not in Power Down mode, the module must represent the correct value of both signals on its outputs before posting a completion of reset interrupt to the host. At no time shall a module cause spurious assertion of the Interrupt pin. When a host initially applies power to a module with the P_Down/RST signal asserted, a module comes up in power down mode. The module shall only assert the Interrupt signal pin to inform the host it has completed a reset. The completion of reset flag shall be the only interrupt source flag set during power down mode. The host is expected to clear this interrupt before releasing the module from the power down mode. The transition from power down mode to normal mode will trigger a reset of the module and result in a nd module reset and a nd reset completion interrupt to the host. Power Supply and Grounding: The power supply line should be well-filtered. All 0.1μF power supply bypass capacitors should be as close to the transceiver module as possible. Oplink Communications, LLC 5

Package Outline XR0.8MAX 6.9 ±0.15.3 71.1MAX 6.1MIN 44.1 ±0.1 R0.3MAX XR1.0 ±0. 1.0 ±0.1 1.7 8.5 ±0.1 0.6 X 45 1.9 ±0.15 7.1 18.4 1.0 ±0.1 PCB THK.5 17.1 5.8 ±0.1 13. ±0.1 PCB WIDTH 1.7 X1.0 18.35 ±0.10 41.6 DIMENSION IN MILLIMETERS NOTES: UNLESS OTHERWISE SPECIFIED Ordering Information Model Name TXD3XGGIC00061G - 5 C to +70 C Commercial 158.77 196.1 61 Red 40km TXD3XGGIC00060G - 5 C to +70 C Commercial 159.55 196 60 Red 40km TXD3XGGIC00059G - 5 C to +70 C Commercial 1530.33 195.9 59 Red 40km TXD3XGGIC00058G - 5 C to +70 C Commercial 1531.1 195.8 58 Red 40km TXD3XGGIC00057G - 5 C to +70 C Commercial 1531.90 195.7 57 Red 40km TXD3XGGIC00056G - 5 C to +70 C Commercial 153.68 195.6 56 Red 40km TXD3XGGIC00055G - 5 C to +70 C Commercial 1533.47 195.5 55 Red 40km TXD3XGGIC00054G - 5 C to +70 C Commercial 1534.5 195.4 54 Red 40km TXD3XGGIC00053G - 5 C to +70 C Commercial 1535.04 195.3 53 Red 40km TXD3XGGIC0005G - 5 C to +70 C Commercial 1535.8 195. 5 Red 40km TXD3XGGIC00051G - 5 C to +70 C Commercial 1536.61 195.1 51 Red 40km TXD3XGGIC00050G - 5 C to +70 C Commercial 1537.40 195.0 50 Red 40km TXD3XGGIC00049G - 5 C to +70 C Commercial 1538.19 194.9 49 Red 40km TXD3XGGIC00048G - 5 C to +70 C Commercial 1538.98 194.8 48 Red 40km TXD3XGGIC00047G - 5 C to +70 C Commercial 1539.77 194.7 47 Red 40km Oplink Communications, LLC 6

Model Name TXD3XGGIx000xxG TXD3XGGIC00046G - 5 C to +70 C Commercial 1540.56 194.6 46 Red 40km TXD3XGGIC00045G - 5 C to +70 C Commercial 1541.35 194.5 45 Red 40km TXD3XGGIC00044G - 5 C to +70 C Commercial 154.14 194.4 44 Red 40km TXD3XGGIC00043G - 5 C to +70 C Commercial 154.94 194.3 43 Red 40km TXD3XGGIC0004G - 5 C to +70 C Commercial 1543.73 194. 4 Red 40km TXD3XGGIC00041G - 5 C to +70 C Commercial 1544.53 194.1 41 Red 40km TXD3XGGIC00040G - 5 C to +70 C Commercial 1545.3 194.0 40 Red 40km TXD3XGGIC00039G - 5 C to +70 C Commercial 1546.1 193.9 39 Red 40km TXD3XGGIC00038G - 5 C to +70 C Commercial 1546.9 193.8 38 Red 40km TXD3XGGIC00037G - 5 C to +70 C Commercial 1547.7 193.7 37 Red 40km TXD3XGGIC00036G - 5 C to +70 C Commercial 1548.51 193.6 36 Red 40km TXD3XGGIC00035G - 5 C to +70 C Commercial 1549.3 193.5 35 Red 40km TXD3XGGIC00034G - 5 C to +70 C Commercial 1550.1 193.4 34 Red 40km TXD3XGGIC00033G - 5 C to +70 C Commercial 1550.9 193.3 33 Red 40km TXD3XGGIC0003G - 5 C to +70 C Commercial 1551.7 193. 3 Red 40km TXD3XGGIC00031G - 5 C to +70 C Commercial 155.5 193.1 31 Red 40km TXD3XGGIC00030G - 5 C to +70 C Commercial 1553.33 193.0 30 Red 40km TXD3XGGIC0009G - 5 C to +70 C Commercial 1554.13 19.9 9 Red 40km TXD3XGGIC0008G - 5 C to +70 C Commercial 1554.94 19.8 8 Red 40km TXD3XGGIC0007G - 5 C to +70 C Commercial 1555.75 19.7 7 Red 40km TXD3XGGIC0006G - 5 C to +70 C Commercial 1556.55 19.6 6 Red 40km TXD3XGGIC0005G - 5 C to +70 C Commercial 1557.36 19.5 5 Red 40km TXD3XGGIC0004G - 5 C to +70 C Commercial 1558.17 19.4 4 Red 40km TXD3XGGIC0003G - 5 C to +70 C Commercial 1558.98 19.3 3 Red 40km TXD3XGGIC000G - 5 C to +70 C Commercial 1559.79 19. Red 40km TXD3XGGIC0001G - 5 C to +70 C Commercial 1560.61 19.1 1 Red 40km TXD3XGGIC0000G - 5 C to +70 C Commercial 1561.4 19.0 0 Red 40km TXD3XGGIC00019G - 5 C to +70 C Commercial 156.3 191.9 19 Red 40km TXD3XGGIC00018G - 5 C to +70 C Commercial 1563.05 191.8 18 Red 40km TXD3XGGIC00017G - 5 C to +70 C Commercial 1563.86 191.7 17 Red 40km Model Name TXD3XGGIE00061G - 5 C to +85 C Extended 158.77 196.1 61 Red 40km TXD3XGGIE00060G - 5 C to +85 C Extended 159.55 196 60 Red 40km TXD3XGGIE00059G - 5 C to +85 C Extended 1530.33 195.9 59 Red 40km TXD3XGGIE00058G - 5 C to +85 C Extended 1531.1 195.8 58 Red 40km TXD3XGGIE00057G - 5 C to +85 C Extended 1531.90 195.7 57 Red 40km TXD3XGGIE00056G - 5 C to +85 C Extended 153.68 195.6 56 Red 40km TXD3XGGIE00055G - 5 C to +85 C Extended 1533.47 195.5 55 Red 40km TXD3XGGIE00054G - 5 C to +85 C Extended 1534.5 195.4 54 Red 40km TXD3XGGIE00053G - 5 C to +85 C Extended 1535.04 195.3 53 Red 40km TXD3XGGIE0005G - 5 C to +85 C Extended 1535.8 195. 5 Red 40km Oplink Communications, LLC 7

Model Name TXD3XGGIx000xxG TXD3XGGIE00051G - 5 C to +85 C Extended 1536.61 195.1 51 Red 40km TXD3XGGIE00050G - 5 C to +85 C Extended 1537.40 195.0 50 Red 40km TXD3XGGIE00049G - 5 C to +85 C Extended 1538.19 194.9 49 Red 40km TXD3XGGIE00048G - 5 C to +85 C Extended 1538.98 194.8 48 Red 40km TXD3XGGIE00047G - 5 C to +85 C Extended 1539.77 194.7 47 Red 40km TXD3XGGIE00046G - 5 C to +85 C Extended 1540.56 194.6 46 Red 40km TXD3XGGIE00045G - 5 C to +85 C Extended 1541.35 194.5 45 Red 40km TXD3XGGIE00044G - 5 C to +85 C Extended 154.14 194.4 44 Red 40km TXD3XGGIE00043G - 5 C to +85 C Extended 154.94 194.3 43 Red 40km TXD3XGGIE0004G - 5 C to +85 C Extended 1543.73 194. 4 Red 40km TXD3XGGIE00041G - 5 C to +85 C Extended 1544.53 194.1 41 Red 40km TXD3XGGIE00040G - 5 C to +85 C Extended 1545.3 194.0 40 Red 40km TXD3XGGIE00039G - 5 C to +85 C Extended 1546.1 193.9 39 Red 40km TXD3XGGIE00038G - 5 C to +85 C Extended 1546.9 193.8 38 Red 40km TXD3XGGIE00037G - 5 C to +85 C Extended 1547.7 193.7 37 Red 40km TXD3XGGIE00036G - 5 C to +85 C Extended 1548.51 193.6 36 Red 40km TXD3XGGIE00035G - 5 C to +85 C Extended 1549.3 193.5 35 Red 40km TXD3XGGIE00034G - 5 C to +85 C Extended 1550.1 193.4 34 Red 40km TXD3XGGIE00033G - 5 C to +85 C Extended 1550.9 193.3 33 Red 40km TXD3XGGIE0003G - 5 C to +85 C Extended 1551.7 193. 3 Red 40km TXD3XGGIE00031G - 5 C to +85 C Extended 155.5 193.1 31 Red 40km TXD3XGGIE00030G - 5 C to +85 C Extended 1553.33 193.0 30 Red 40km TXD3XGGIE0009G - 5 C to +85 C Extended 1554.13 19.9 9 Red 40km TXD3XGGIE0008G - 5 C to +85 C Extended 1554.94 19.8 8 Red 40km TXD3XGGIE0007G - 5 C to +85 C Extended 1555.75 19.7 7 Red 40km TXD3XGGIE0006G - 5 C to +85 C Extended 1556.55 19.6 6 Red 40km TXD3XGGIE0005G - 5 C to +85 C Extended 1557.36 19.5 5 Red 40km TXD3XGGIE0004G - 5 C to +85 C Extended 1558.17 19.4 4 Red 40km TXD3XGGIE0003G - 5 C to +85 C Extended 1558.98 19.3 3 Red 40km TXD3XGGIE000G - 5 C to +85 C Extended 1559.79 19. Red 40km TXD3XGGIE0001G - 5 C to +85 C Extended 1560.61 19.1 1 Red 40km TXD3XGGIE0000G - 5 C to +85 C Extended 1561.4 19.0 0 Red 40km TXD3XGGIE00019G - 5 C to +85 C Extended 156.3 191.9 19 Red 40km TXD3XGGIE00018G - 5 C to +85 C Extended 1563.05 191.8 18 Red 40km TXD3XGGIE00017G - 5 C to +85 C Extended 1563.86 191.7 17 Red 40km Model Name TXD3XGGII00061G - 40 C to +85 C Industrial 158.77 196.1 61 Red 40km TXD3XGGII00060G - 40 C to +85 C Industrial 159.55 196 60 Red 40km TXD3XGGII00059G - 40 C to +85 C Industrial 1530.33 195.9 59 Red 40km TXD3XGGII00058G - 40 C to +85 C Industrial 1531.1 195.8 58 Red 40km TXD3XGGII00057G - 40 C to +85 C Industrial 1531.90 195.7 57 Red 40km Oplink Communications, LLC 8

Model Name TXD3XGGII00056G - 40 C to +85 C Industrial 153.68 195.6 56 Red 40km TXD3XGGII00055G - 40 C to +85 C Industrial 1533.47 195.5 55 Red 40km TXD3XGGII00054G - 40 C to +85 C Industrial 1534.5 195.4 54 Red 40km TXD3XGGII00053G - 40 C to +85 C Industrial 1535.04 195.3 53 Red 40km TXD3XGGII0005G - 40 C to +85 C Industrial 1535.8 195. 5 Red 40km TXD3XGGII00051G - 40 C to +85 C Industrial 1536.61 195.1 51 Red 40km TXD3XGGII00050G - 40 C to +85 C Industrial 1537.40 195.0 50 Red 40km TXD3XGGII00049G - 40 C to +85 C Industrial 1538.19 194.9 49 Red 40km TXD3XGGII00048G - 40 C to +85 C Industrial 1538.98 194.8 48 Red 40km TXD3XGGII00047G - 40 C to +85 C Industrial 1539.77 194.7 47 Red 40km TXD3XGGII00046G - 40 C to +85 C Industrial 1540.56 194.6 46 Red 40km TXD3XGGII00045G - 40 C to +85 C Industrial 1541.35 194.5 45 Red 40km 46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-700 Fax: (510) 933-7300 Email: Sales@Oplink.com www.oplink.com TXD3XGGII00044G - 40 C to +85 C Industrial 154.14 194.4 44 Red 40km TXD3XGGII00043G - 40 C to +85 C Industrial 154.94 194.3 43 Red 40km TXD3XGGII0004G - 40 C to +85 C Industrial 1543.73 194. 4 Red 40km TXD3XGGII00041G - 40 C to +85 C Industrial 1544.53 194.1 41 Red 40km TXD3XGGII00040G - 40 C to +85 C Industrial 1545.3 194.0 40 Red 40km TXD3XGGII00039G - 40 C to +85 C Industrial 1546.1 193.9 39 Red 40km TXD3XGGII00038G - 40 C to +85 C Industrial 1546.9 193.8 38 Red 40km TXD3XGGII00037G - 40 C to +85 C Industrial 1547.7 193.7 37 Red 40km TXD3XGGII00036G - 40 C to +85 C Industrial 1548.51 193.6 36 Red 40km TXD3XGGII00035G - 40 C to +85 C Industrial 1549.3 193.5 35 Red 40km TXD3XGGII00034G - 40 C to +85 C Industrial 1550.1 193.4 34 Red 40km TXD3XGGII00033G - 40 C to +85 C Industrial 1550.9 193.3 33 Red 40km TXD3XGGII0003G - 40 C to +85 C Industrial 1551.7 193. 3 Red 40km TXD3XGGII00031G - 40 C to +85 C Industrial 155.5 193.1 31 Red 40km TXD3XGGII00030G - 40 C to +85 C Industrial 1553.33 193.0 30 Red 40km TXD3XGGII0009G - 40 C to +85 C Industrial 1554.13 19.9 9 Red 40km TXD3XGGII0008G - 40 C to +85 C Industrial 1554.94 19.8 8 Red 40km TXD3XGGII0007G - 40 C to +85 C Industrial 1555.75 19.7 7 Red 40km TXD3XGGII0006G - 40 C to +85 C Industrial 1556.55 19.6 6 Red 40km TXD3XGGII0005G - 40 C to +85 C Industrial 1557.36 19.5 5 Red 40km TXD3XGGII0004G - 40 C to +85 C Industrial 1558.17 19.4 4 Red 40km TXD3XGGII0003G - 40 C to +85 C Industrial 1558.98 19.3 3 Red 40km TXD3XGGII000G - 40 C to +85 C Industrial 1559.79 19. Red 40km TXD3XGGII0001G - 40 C to +85 C Industrial 1560.61 19.1 1 Red 40km TXD3XGGII0000G - 40 C to +85 C Industrial 1561.4 19.0 0 Red 40km TXD3XGGII00019G - 40 C to +85 C Industrial 156.3 191.9 19 Red 40km TXD3XGGII00018G - 40 C to +85 C Industrial 1563.05 191.8 18 Red 40km TXD3XGGII00017G - 40 C to +85 C Industrial 1563.86 191.7 17 Red 40km Oplink Communications, LLC. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Communications, LLC. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, LLC. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, LLC. 017, Oplink Communications, LLC. 9