For the diagnosis of Hirschsprung s Disease

Similar documents
Heyinovo. Disposable Biopsy Valves User Manual. Technical Publications. Document No: WI-RD-13-M07, Rev. B

A Complete Line of Ophthalmic Knives

Instructions for Use A-dec Quick-Disconnect Syringes

LDR Brachytherapy Seed Sterilization and Sorting Tray

CONTROL IS EVERYTHING THE SURGEON S EDGE

HD-S B-3 B-2. No Fig. 2. Recommended vessel diameter (mm) B-1 B-2 B-3 HD-S

Crimp & Cleave Termination Instructions for 200 µm F07 Connectors

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

Blades. About Southmedic. Polymer Coated Blades. Sterile Stainless Blades

SURGICAL TECHNIQUE. Legend Acetabular Shell

Exactly the specialised medical supplies you want, when you need them. Gynaecology Solutions FREECALL

JARVIS. Model 70 Airsnip Air Powered Scissors

Cultures, Specimen Collection for

Paracentesis Incision Knives

diego Blade and Burr Guide

M i c r o s u r g i c a l K n i v e s

ArcRoyal Operating Room Solutions. Delivering Excellence in Custom Solutions

PM-X IR SURGICAL POWER & ACCESSORIES

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

Crimp & Cleave Termination Instructions

Crimp & Cleave Termination Instructions for 200 µm Factory5 Cable with ST and SMA Connectors

Procedure Guidelines Protocol Title:

CONTROL IS EVERYTHING THE SURGEON S EDGE

high performance pipettors Excellence and precision for all your liquid handling procedures.

Two Piece Low Torque Kelly Valve

Phantom Retractor System Overview

Crimp & Cleave Termination Instructions

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

METAL MAX Reliability Challenge Please contact NEXT Medical Products Company to take part! See details on reverse - terms and conditions apply.

TECHNICAL DATA SHEET EZE Hub Shoring System

Rhino-Rack SUNSEEKER II Awning 2.0 metres (32109)

Crimp & Cleave Termination Instructions

Rhino-Rack SUNSEEKER II Awning (32105)

RIBBEL INTERNATIONAL LTD.

Rhino-Rack SUNSEEKER II Awning

Getting Straight to the Point. Blades & Scalpels

Viewline Retractor System

Thoracic Drainage - Pleural Puncture - Accessories

I N T R O D U C T I O N

APPENDIX KING VISION VIDEO LARYNGOSCOPE

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

Snowden-Pencer reposable takeapart

DISPOSABLE INSTRUMENTS

Getting Straight to the Point. Blades & Scalpels

Face-Bow with Quick Lock Toggle Assembly Instructions

electric knife sharpener

CUTTING EDGE ILLUMINATION

Crimp & Cleave Termination Instructions for 200 µm Harsh Environment SMA

Thoracic Drainage - Pleural Puncture - Accessories

30m Foot Pedal Hose Reel

How to Open a Glass Vial

COMBI CRATE MODEL NO: 7000/7001/7002/7003

An ISO 13485:2016 & US-FDA Audited Co.

BIOPSY FORCEPS HIGH RELIABILITY WITH AN OPTIMAL BITE PERFORMANCE CHARACTERISTICS

TN5000 Titan Manual Rotary Microtome

SYSTIMAX RoloSplice Multiple Splice Organizer Installation

Otter Pro X-Over Lodge Installation and Set-Up Instructions

Gas Conversion Kits and Instructions

VEPR Round Drum Disassembly and Assembly

One Piece Low Torque Kelly Valve. Preventive Maintenance Service Video Disassembly and Assembly Procedures

Ceramic Liner Inserter. Surgical Technique

Pericardiocentesis Simulator with Chest Tube and Pneumothorax LF03769U Instruction Manual

WARNING: Read these materials prior to assembling and using this trampoline and enclosure

Reprocessed Device for Single Use. Reprocessed by. Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

AVANTAGE. Acetabulum System. Surgical Technique

Ceramic Probe Replacement Instructions Accessory G

FREEDOM BUTTON KIT INSTALLATION GUIDE STEP 1

Retractor Kit Rev: D. Instruction For Use NEXT ORTHOSURGICAL 3270 CORPORATE VIEW, SUITE A VISTA CA /1/14

DO NOT use Alien Flier Zip Line Products until you have read and fully understand the SAFETY WARNINGS below!

Contents. Company Background FLOWSTOPPER Plugging Device Kit and Replacement Parts Key Features & Benefits... 4

SPECIFICATIONS. For 1 8 OD Tubing FERRULES FOR 1 8 OD TUBING. One piece PTFE ferrule with SS casing1. One piece PTFE ferrule with SS casing2 008FT32

LESSON ASSIGNMENT. Surgical Asepsis and Sterile Technique. After completing this lesson, you should be able to:

BowDown. MiniMuM Crossbar spread 24 (61CM) Steel Hook (2X) Buckle Strap (2X) Plastic Tube (2X) Plain Strap (2X) SHORT BLACK T-BOLT (2x) BOWDOWN (2x)

Galt Medical Corp. A leader in vascular and interventional medical devices. OEM Division

Viewline Tube Retraction System

CONTENTS. Specifications of all products mentioned are indicative only

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

Applications Engineering Notes

Operating Instructions

Tuke Saw System. Operating Manual. Safe Navigation Through Soft Tissue

Corning Aspirator Instruction Manual

ASSEMBLY INSTRUCTIONS

ACCESSORY DEVICES for Your Vein Practice CHOICE VALUE CONVENIENCE

Standardised Parenteral Support Catheter Guidelines

How to Use Your Implanted Venous Port

Instructions for Use: Duodenoscope Sampling Kit

Mixpac TM B-System Application System for 2-Component Products 25 ml, 50 ml and 75 ml

AEROtube ET-Holder Laryngoscopes Laryngeal masks Endotracheal tubes Oropharyngeal tubes

Blue Series Hot Melt Hose with RediFlext II Hanger System

MOUTH AND THROAT INSTRUMENTS

Fibre Mesh Wedge User Instructions. Simple Stuff Works

Applications Engineering Notes

Electric 2-STAGE SHARPENING FEATURES: system allows for safe, easy knife sharpening - Non-slip feet allows sharpener to stay in place while in use

CRASH KELLY. Directions for Use

Mandolin Slicer Quite possibly the safest mandolin in the world

Installation and Maintenance Manual

Thermostatic Griddle Field Service Kit Instructions

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System

Transcription:

For the diagnosis of Hirschsprung s Disease Suction Rectal Biopsy System Suitable for use with: Neonates - Adolescents - Adults World s #1 System Patent No US 7,479,117 B2

Controlled Consistent Rectal Biopsies The rbi2 is the world s #1 suction rectal biopsy system used to obtain controlled consistent biopsies of mucosa and sub mucosa for pathological examination for the diagnosis of Hirschsprung s Disease. Eliminating problems associated with older suction rectal biopsy equipment, the rbi2 is a hybrid system made up of a sterile, single-use capsule, a re-useable handpiece and a negative pressure manometer. The capsule houses an ultra-sharp blade for a clean cut, provides an airtight seal for precise suction and features a unique snap system to break the capsule for easy retrieval and viewing of the biopsy specimen. Self-calibrating between biopsies and with highly visible indication markers, the negative pressure, single patient use manometer assists the operator to achieve neutral capsule pressure against the mucosa and provides repeatable readings. rbi2 Features suitable for use with neonates, adolescents, adults a clean, precise cut consistent suction uniform specimens easy specimen access totally enclosed scalpel sharp blade measuring indicators suitable for left & right handed operators

Best Performance To get the best performance from your rbi2 suction rectal system, it s important to understand the unique characteristics and essential techniques associated with using the device. Take your time There is no need to quickly fire the trigger once the suction is achieved. Because this system is airtight, there will be no loss of suction whilst taking the biopsy so take your time! Minimal suction required with this airtight system The unique design of the rbi2 capsule features an internal seal that fits tightly around the inner tube of the handpiece. This provides an airtight pathway from the front of the capsule all the way to the syringe. As a result, additional suction to account for suction loss, which is a technique used with older systems is not necessary. Make sure the specimen has been released into the capsule tip... Prior to firing the trigger, the mucosa is drawn into the hole in front of the blade. When the trigger is fired the blade cuts the specimen and becomes lodged in the cutting block. When the blade is fully advanced into the cutting block the specimen is released into the capsule tip for retrieval. After withdrawing the instrument from the patient, and prior to breaking the capsule open for specimen retrieval, check that the hole in the blade aligns with the hole in the capsule you should see no silver blade. If you can still see blade, simply fire the trigger to push the blade fully forward. Failure to do this may make specimen removal difficult as it is possible the specimen will remain trapped between the blade and the cutting block.

Fig. 1 Fig. 2 3 Understanding the critical combination of negative suction pressure and gentle approximation of the capsule against the mucosa The single patient use manometer measures the amount of negative suction pressure and is used as a guide to let the operator know if the capsule is not placed against the mucosa. A successful biopsy will be achieved when the capsule hole is covered by the mucosa, with the capsule itself gently approximated in the neutral position against the mucosa. The blue diaphragm of the manometer will only react if the hole is covered - see Fig 1. The manometer will not indicate if too much pressure is being applied against the mucosa so it is critical not to push the capsule against the mucosa to avoid inadequate specimens. Fig. 3 7 Do not deliberately force the capsule against the mucosa... Gently approximate the capsule tip in the neutral position to the mucosa - see Fig 2. Do not push or force the capsule against the mucosa. The mucosa will stretch and tighten, making it more difficult to withdraw the tissue into the capsule hole - see Fig 3. or prevent tissue from entering the hole altogether. (please refer to the package insert for full instructions for use)

Product Details Order Code: CP1200 Procedure Packs (10 single use procedure packs) 3 capsules per pack supplied sterile (gamma) scalpel sharp blade blade totally enclosed - no accidental sharps injuries internal seal - consistent suction control consistent, accurate aspiration consistent specimen no instrument servicing or blade sharpening required 5 x 10mm depth measuring indicators no internal blade lubrication required disposable capsule, blade, seal, tubing & adaptor - infection reduction quick twist and lock system suits left and right handed operation quick snap for easy access to specimen specimen captured in front section of capsule instructions for use with each procedure pack Order Code: MR100 Negative Pressure Manometer (10 single use units per box) supplied sterile (gamma) highly visible identification markers self calibrating between biopsies allows neutral capsule pressure against mucosa repeatable readings Order Code: HP1000 Handpiece re-useable, easy to clean & heat sterilisable (autoclavable) easy to use thumb trigger light comfortable handle for steady placement easy assembly and disassembly Order Code: SS1000 Sterilisation/Storage Container individual component pockets re-useable & heat sterilisable (autoclavable) marked with assembly & disassembly instructions clear top for easy identification Manufactured in Australia

CAUTION: For use on or by the order of a physician only CAUTION: (US) Law restricts these devices to sale by or on the order of a physician only. This device should be used only by physicians familiar with the device, it s intended use, any additional instrumentation and any available surgical techniques. Responsibility for correct patient selection, adequate training and experience in performing suction rectal biopsies rests with the physician. Head Office: Australia Aus systems Pty Ltd 3 Charles Street Allenby Gardens South Australia 5009 Ph: +61 8 8346 6400 Fx: +61 8 8346 6411 rbi2@aussystems.com.au www.aussystems.com.au European Sales Hub: Sigmacon (UK) Limited Ph: +44 (0) 208 901 0280 Fx: +44 (0) 208 950 9199 info@sigmacon.co.uk 2011 TFS Surgical VN : R2596/V1 USA Distributor: Specialty Surgical Products, INC Toll Free: 888 878 0811 Ph: +1 406 961 0102 Fx: +1 406 961 0103 customerservice@ssp-inc.com 2011 Aus systems Pty Ltd VN: R2812/V2