How to Open a Glass Vial

Similar documents
LESSON ASSIGNMENT. Surgical Asepsis and Sterile Technique. After completing this lesson, you should be able to:

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

How to Use Your Implanted Venous Port

Mixing Your Alpha-1 Therapy Aralast NP

Instructions for Use Repatha (ri-path-a) (evolocumab) Single-Use Prefilled SureClick Autoinjector. Guide to parts

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

Instructions for Use

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

Operating Instructions

Instructions for Use AIMOVIG TM (AIM-oh-vig) (erenumab-aooe) Injection, For Subcutaneous Use Single-Dose Prefilled SureClick Autoinjector

How to safely collect blood samples by phlebotomy from patients suspected to be infected with Ebola or Marburg

Baxter, ADVATE Antihemophilic Factor (Recombinant)

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

Performing Hand Hygiene Using an Alcohol-Based Handrub

Caring for Your Chest Tube and Pneumostat Chest Drain Valve

NNIN Nanotechnology Education

Applications Engineering Notes

Making Solar Cells 1 from Household Materials (mostly :)

FagronLab FG. Semi-automatic capsule filling machine. User Manual

Standardised Parenteral Support Catheter Guidelines

Great Plastic Pick Up

British Intestinal Failure Alliance (BIFA) Guidance. Standardised Parenteral Support Catheter Guidelines

Crimp & Cleave Termination Instructions

LBH18BPK. Instruction Sheet

Field Situation - How to safely collect oral swabs (saliva) from deceased patients suspected to be infected with Ebola

Applications Engineering Notes

LABORATORY SAFETY RULES AND GUIDELINES FOR WORKING IN CHEMISTRY LABS AT OCCC

SYSTIMAX RoloSplice Multiple Splice Organizer Installation

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

1. COMPONENT IDENTIFICATION

Cultures, Specimen Collection for

Sectioning Paraffin Blocks

How to safely collect oral swabs (saliva) from deceased patients suspected to be infected with Ebola or Marburg

Home Care for Your Gravity Fluid Drain

For the diagnosis of Hirschsprung s Disease

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

THIS CLIPPER IS INTENDED FOR HOUSEHOLD USE ONLY.

COMPONENT IDENTIFICATION

Get A Grip! Student Activity 1D Introduction: Materials: (per group) LESSON 2

TECHNICAL INFORMATION Primer Residue Collection Kit for SEM, ICP-MS and AAA Catalog No. GRA100

Crimp & Cleave Termination Instructions for 200 µm F07 Connectors

FREEDOM BUTTON KIT INSTALLATION GUIDE STEP 1

HZS Field Spectroscopy Kit

3M PPS Series 2.0 Spray Cup System The next evolution of painting productivity

Applications Engineering Notes

Caring for Your Closed Bulb Drain For a Jackson-Pratt (JP) or Blake drain

Heyinovo. Disposable Biopsy Valves User Manual. Technical Publications. Document No: WI-RD-13-M07, Rev. B

Adult Diaper. Our Adult Diapers are Ultra Absorbent with 10 SAP for best convenience to patients and one of the best available in India.

Instructional Booklet

Home parenteral nutrition

Accu-Chart TM Healthcare Systems, Inc.

Crimp & Cleave Termination Instructions for 200 µm Harsh Environment SMA

Electric 2-STAGE SHARPENING FEATURES: system allows for safe, easy knife sharpening - Non-slip feet allows sharpener to stay in place while in use

Pediatric Central Line Care

Adult Diapers. Anti Bacteria Anti Odour Anti Allergy Wetness Indicator Extra Absorbent Leak Proof

Hose Reel Retraction Issues Version 1.1

MEDICAL EQUIPMENT AS PER MS NOTICE MSN1768 AND MFAG Appendix 14 EQUIPMENT AS PER MS NOTICE MSN1768 AND MFAG Appendix 14 Sr. IMPA CODE Equipment ITEM

Procedure Guidelines Protocol Title:

ELECTRIC KNIFE SHARPENER User Guide

SOURCE: Infection Prevention & Control (IPC)

Science Safety Rules DATE: Section: My group members: (write their first and last names in this box)

A GUIDE TO ORGANISING YOUR Great British Spring Clean event THE #GBSPRINGCLEAN

How to Use a Port-a-Cath

FISH CAT SCOUT OWNER S MANUAL

Instructions for Use: Duodenoscope Sampling Kit

Crimp & Cleave Termination Instructions

Deep Cleaning a Passap is a three step process: Tear down, Clean, and Reassemble.

Crimp & Cleave Termination Instructions for 200 µm Factory5 Cable with ST and SMA Connectors

1 Pan - 6 Ways to Cook! Works in the Oven & On All Stovetops! electric gas ceramic induction. Broil Bake Sauté Fry Steam Braise

Cleaning & Disinfection of Eickview Videoendoscopes

Crimp & Cleave Termination Instructions

COMPONENT IDENTIFICATION

1. COMPONENT IDENTIFICATION

COMPONENT IDENTIFICATION

User Manual. 110 Cup (55 Cup Raw) Rice Cooker. Model: 177GRCLP, 177GRCNAT 10/2017. Please read and keep these instructions. Indoor use only.

UNIVERSAL PANEL & EASY PLUMB KIT

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

Serving up safety: A Health and Safety Tip Sheet for. Did you know? Step 1. Identify job hazards. Step 2. Work towards solutions

Retractable Hose Reel

high performance pipettors Excellence and precision for all your liquid handling procedures.

Cederroth First Aid Product Catalogue

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

Oster Golden A5 Care and Maintenance

Giving Tube Feedings at Home (by Gravity)

Laboratory Safety. A practical approach.

Keeping your Workplace Safe for Foodservice Employees

/ Tool and Equipment Safety Tether System (T.E.S.T.S)

DIAMOND TECH INTERNATIONAL Innovations For Creativity DIAMOND LASER BAND SAW OPERATIONS MANUAL

Safety and Rules of the Lab

COMPONENT IDENTIFICATION

User Guide. Tripod. flowtech 75 Tripod. Part No. V

Instruction Manual please read before use

STEALTH PRO OWNER S MANUAL

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

BowDown. MiniMuM Crossbar spread 24 (61CM) Steel Hook (2X) Buckle Strap (2X) Plastic Tube (2X) Plain Strap (2X) SHORT BLACK T-BOLT (2x) BOWDOWN (2x)

Advantage. Purpose Animal anesthesia injections, fire rope launcher, Forest products collection, Fishery, Scuba diving harpoon.

Innovative New Products

APPENDIX KING VISION VIDEO LARYNGOSCOPE

Written by: Kate Florio, Liberty Science Center. Grade Level: change when the mass of an object changes. 20 mins. Lesson Time: 45 min.

Transcription:

How to Open a Glass Vial Year Group: BVSc3 + Document Number: CSL_U07

Equipment list: How to Open a Glass Vial Equipment for this station: 10ml glass vial of water for injection Swab Bottle of surgical spirit Paper towel 10ml syringe 22G needle Vial (ampule) cap (for Ampule Cap Method ) Considerations for this station: Be careful when handling glass Needles are sharp and can cause injury Dispose of sharps in a sharps bin Please refer to the instruction booklet CSL_U02 Safe Use of Needles for instructions on how to use, dispose of or re-cap needles (e.g. if reusing needles) For more information please refer to General Risk Assessment Form: Needles CSL_R03 (in the CSL) Please reuse syringes Anyone working in the Clinical Skills Lab must read the CSL_I01 Induction and agree to abide by the CSL_I00 House Rules & CSL_I02 Lab Area Rules Please inform a member of staff if equipment is damaged or about to run out.

Clinical Skills: How to Open a Glass Vial: Paper Towel Method 1 2 3 Fluid It is good practice to wipe the vial neck with an alcohol swab (or a swab soaked in surgical spirit) prior to opening. In the Clinical Skills Lab (CSL) if a swab is not available start the station at step 2. Prepare all the equipment i.e. a couple of sheets of paper towel, a needle and syringe (attach the capped needle to the syringe using an aseptic technique - refer to booklet CSL_U02 Safe use of Needles ). The vial may have fluid in the top part above the narrow neck see red arrow in photo above. 4 5 Dot 6 If there is fluid above the neck, hold the glass vial in your non-dominant hand and gently flick the top of the vial (using your dominant hand) until all the fluid is in the base of the vial. Orientate the vial so that the coloured (blue) dot is facing towards you (indicated by the red arrows in the photos above). Pick up the sheets of paper towel with your dominant hand and place them around the vial top with your thumb just above the position of the coloured dot and your index finger on the other side. Alternatively have your thumb on the side furthest away and your index finger just above the blue dot.

Clinical Skills: How to Open a Glass Vial: Paper Towel Method 7 8 9 Snap the vial neck by applying pressure while bending the neck away from the dot (and away from yourself). Dispose of the broken off glass top in a sharps bin. Hold the vial with your nondominant hand and with your dominant hand pick up the syringe and needle and withdraw the liquid. Keep the vial at an angle while drawing up the contents. 10 11 12 If air is drawn into the syringe there may be insufficient space for all the liquid. If this is the case, stop drawing up the liquid, hold the syringe with the needle pointing upwards so the air is at the top and press the plunger to expel the air. Then continue drawing up the liquid. It may be necessary to invert the vial to remove the last drops of liquid. Be careful not to inject air and break the surface tension or the liquid will pour out. Dispose of the empty vial in a sharps bin and safely recap the needle (see booklet CSL_U02 Safe use of Needles ).

Clinical Skills: How to Open a Glass Vial: Ampule Cap Method 1 2 3 It is useful to be aware of other methods for opening vials e.g. Ampule Cap Method using a single-use cap. N.B. First complete steps 1 5 described in the previous section How to Open a Glass Vial: Paper Towel Method Place the cap over the ampule (vial) top, slotting the cap end with the tight collar over the top of the ampule, until it clicks into place. Hold the cap firmly in one hand and the body of the ampule (vial) in the other hand. 4 5 6 Firmly and steadily bend the cap away from the coloured dot (visible on the vial neck) until the vial snaps at the neck. Dispose of the cap (containing the broken vial top) into a sharps bin. The cap is single use only. Continue to aspirate the contents of the vial as described in How to open a glass vial paper towel method in the previous pages.

How to Open a Glass Vial: Other Methods & How to Withdraw Medication There are other tools designed specially to open a vial, for example an Ampule Opener. It is possible to use the barrel of an empty syringe; place the barrel over the neck of the vial and snap it off. See YouTube video: Techniques to break an ampule and withdraw out from an ampule or scan the QR code: To clarify the correct way to withdraw medications using a needle and syringe see YouTube video: Withdraw medication from a vial or scan the QR code:

Resetting the station: How to Open a Glass Vial 1. Empty the water for injection in the syringe down the sink 2. Leave the needle and syringe at the station 3. Ensure that all sharps have been disposed of in a sharps bin 4. Put the paper towel in the bin N.B. If contaminated, dispose of in clinical waste 5. Leave the area tidy ready for the next person Station ready for the next person: Please inform a member of staff if equipment is damaged or about to run out.

I wish I d known: How to Open a Glass Vial Try to apply a light, even pressure when snapping the neck of the vial to avoid shattering the glass. The pressure should only be applied by the hand snapping the neck, do not apply pressure to the base of the vial with the other hand. Avoid any pushing, pulling, or twisting actions while applying pressure on the glass vial to open it. Always apply pressure away from the coloured dot, never in any other direction. If in practice you do not have any suitable paper towel, a swab or piece of cloth can be used instead. If the glass vial shatters, do not use the contents. Open a new vial. Glass vials come in various sizes including 2ml, 5ml and 10ml. The same approach applies when opening any of them. Some vials come with a metal file to score the neck. The operator then forces the top away from the score mark (i.e. the same as when applying pressure away from the coloured dot)