Jameco SKU Number: 2101518 240W Single Output with FC Function S-240 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER S-240-5 S-240-7.5 S-240-12 S-240-15 S-240-24 S-240-30 S-240-48 RILE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD U TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE OWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVER VOLTAGE OVER TEMERATURE FAN CONTROL WORKING TEM. WORKING HUMIDITY SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE HARMONIC CURRENT Note.5 STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION EMI CONDUCTION & RADIATION EMS IMMUNITY MTBF DIMENSION ACKING 5V 7.5V 12V 15V 24V 30V 48V 45A 32A 20A 16A 10A 8A 5A 0 ~ 45A 0 ~ 32A 0 ~ 20A 0 ~ 16A 0 ~ 10A 0 ~ 8A 0 ~ 5A 225W 240W 240W 240W 240W 240W 240W 4 ~ 6V 6 ~ 9V 10 ~ 14V 12 ~ 18V 20 ~ 28V 27 ~ 33V 41 ~ 56V 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 800ms, 50ms/230VAC 20ms/230VAC 1500ms, 50ms/115VAC at full load 20ms/115VAC at full load 88 ~ 264VAC 124 ~ 370VDC 47 ~ 63Hz F>0.95/230VAC 79% 3.6A/115VAC 25A/115VAC <2mA / 240VAC 83% F>0.98/115VAC at full load 1.8A/230VAC 40A/230VAC 105 ~ 135% rated output power 86% 86% 87% 88% 89% rotection type : Hiccup mode, recovers automatically after fault condition is removed 6.3 ~ 7.5V 9.4 ~ 10.9V 14.7 ~ 17.5V 19 ~ 22.5V 29.5 ~ 35V 34.7 ~ 41V 57.6 ~ 67.2V rotection type : Shut down o/p voltage, re-power on to recover 90 5 (5V,7.5V), 85 5 (12V,15V,24V,30V,48V) (TSW1 : detect on heatsink of power transistor) rotection type : Shut down o/p voltage, recovers automatically after temperature goes down RTH2 40 FAN ON, 35 FAN OFF(Typ.) -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/-O/:3KVAC I/-FG:1.5KVAC O/-FG:0.5KVAC I/-O/, I/-FG, O/-FG:100M Ohms / 500VDC / 25 Compliance to EN55022 (CISR22) Class B Compliance to EN61000-3-2,-3 / 70% RH Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 284K hrs min. MIL-HDBK-217F (25 ) 190*93*50mm (L*W*H) 0.8Kg; 18pcs/15.4Kg/1.04CUFT File Name:S-240-SEC 2009-09-02
Jameco SKU Number: 2101518 240W Single Output with FC Function S-240 s e ries US-225 S-320 s series Mechanical Specification Case No.987A Unit:mm 9.5 8 20.25 150 20 7 6 5 4 3 2 1 49.5 43.5 4-M4 L=6 41.5 159.5 139.5 133 4-SO M3 L=4 84.5 60.5 44 93 12.5 25 190 20.25 150 Air flow direction 14max. 4-M4 L=6 12.5 25 50 Terminal in No. Assignment in No. Assignment in No. Assignment 1 AC/L 4,5 DC OUTUT -V 2 AC/N 6,7 DC OUTUT +V 3 FG Block Diagram FAN ON/OFF CONTROL FAN fosc : 90KHz I/ EMI FILTER & RECTIFIERS FC CIRCUIT OWER SWITCHING RECTIFIERS +V & -V FILTER FG O.L.. O.T.. WM & FC CONTROL DETECTION CIRCUIT O.V.. Derating Curve Static Characteristics Ta=25 100 100 300 90 250 80 80 200 60 70 150 LOAD (%) 50 40 20 LOAD (%) 60 50 40 100 50 25-20 0 10 20 30 40 50 60 70 (HORIZONTAL) 88 90 95 100 115 135 155 175 195 230 264 AMBIENT TEMERATURE ( ) INUT VOLTAGE (VAC) 60Hz File Name:S-240-SEC 2009-09-02
240W Single Output with FC Function S-240 series MODEL:S-240-24 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1:150 mvp-p (Max ) I/: 230VAC V1: 35 mvp-p (Max ) O/:FULL LOAD 2 OUTUT VOLTAGE ADJUST RANGE CH1:20 V ~ 28 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 19.33 19.33 V ~ V ~ 29.36 29.36 V/ 230 VAC V/ 115 VAC 3 OUTUT VOLTAGE TOLERANCE V1:1 %~ -1 % (Max) I/:100 VAC / 264 VAC O/:FULL/ MIN LOAD V1: 0.05 %~ -0.05 % 4 LINE REGULATION V1: 0.2 %~ -0.2 % (Max) I/:100 VAC ~ 264 VAC O/:FULL LOAD V1: 0 %~ 0 % 5 LOAD REGULATION V1: 0.5 %~ -0.5 % (Max) I/: 230 VAC O/:FULL ~MIN LOAD V1: 0.05 %~ -0.05 % 6 SET U TIME 230VAC: 800 ms (Max) I/: 230 VAC 230VAC/ 400 ms 115VAC: 1500 ms (Max) I/: 115 VAC 115VAC/ 800 ms O/:FULL LOAD 7 RISE TIME 230VAC: 50 ms (Max) I/: 230 VAC 230VAC/ 25 ms 115VAC: 50 ms (Max) I/: 115 VAC 115VAC/ 24 ms O/:FULL LOAD 8 HOLD U TIME 230VAC: 20 ms (TY) I/: 230 VAC 230VAC/ 22 ms 115VAC: 20 ms (TY) I/: 115 VAC 115VAC/ 22 ms O/:FULL LOAD 9 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC O/:FULL LOAD 10 DYNAMIC LOAD V1: 2400 mvp-p I/: 230 VAC O/:FULL /Min LOAD 90%DUTY/ 1KHZ TEST: < +5 % 404 mvp-p Model: S-240-24 Test Report 1 / 6
240W Single Output with FC Function S-240 series INUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 100VAC~264 VAC I/:TESTING O/:FULL LOAD I/: LOW-LINE-3V= 97 V HIGH-LINE+15%=300 V O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) 65 V~264V TEST: OK 2 INUT FREQUENCY RANGE 47HZ ~63 HZ OSC I/:100VAC ~ 264 VAC O/:FULL~MIN LOAD TEST: OK 3 OWER FACTOR 0.95 / 230 VAC(TY) I/: 230 VAC F= 0.971 / 230 VAC 0.98 / 115 VAC(TY) I/: 115 VAC O/:FULL LOAD F= 0.992 / 115 VAC 4 EFFICIENCY 87% (TY) I/: 230 VAC 87.3 % O/:FULL LOAD 5 INUT CURRENT 230V/ 1.8 A (TY) I/: 230 VAC I = 1.24 A/ 230 VAC 115V/ 3.6 A (TY) I/: 115 VAC I = 2.54 A/ 115 VAC O/:FULL LOAD 6 INRUSH CURRENT 230V/ 40 A (TY) I/: 230 VAC I = 35 A/ 230 VAC 115V/ 25 A(TY) I/: 115 VAC I = 17 A/ 115 VAC COLD START O/:FULL LOAD 7 LEAKAGE CURRENT < 2 ma / 240 VAC I/: 264 VAC L-FG: 1.1 ma O/:Min LOAD N-FG: 1.1 ma Model: S-240-24 Test Report 2 / 6
240W Single Output with FC Function S-240 series ROTECTION FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 105 %~ 135 % I/: 230 VAC I/: 115 VAC O/:TESTING 119.6%/ 230 VAC 120.3%/ 115 VAC Hiccup Mode 2 OVER VOLTAGE ROTECTION CH1: 29.5 V~ 35 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 31.2V/ 230 VAC 31.2V/ 115 VAC Shut down Re- power ON 3 OVER TEMERATURE ROTECTION SEC: TSW1: 85+ 5 O.T.. I/: 230 VAC O/:FULL LOAD O.T.. Active Shut down o/p voltage,recovers automatically after temperature goes down 4 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR I/: 264 VAC O/:FULL LOAD Hiccup Mode CONTROL FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 FAN ON/OFF CONTROL (TY) RTH2 40 FAN ON RTH2 35 FAN OFF I/: 230 VAC O/:FULL LOAD 36 35 FAN ON FAN OFF Model: S-240-24 Test Report 3 / 6
240W Single Output with FC Function S-240 series ENVIRONMENT TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL:S-240-5 1. ROOM AMBIENT BURN-IN:0.5 HRS I/: 230VAC O/: FULL LOAD Ta= 26.6 2. HIGH AMBIENT BURN-IN: 2 HRS I/: 230VAC O/: FULL LOAD Ta= 49.5 NO osition /N ROOM AMBIENT Ta= 26.6 HIGH AMBIENT Ta= 49.5 1 LF1 LF108-R2 38.9 56.7 2 BD1 6A/800V GLASS KBJ608G 45.2 65.0 3 TSW1 ST-22W-R2 90 45.7 64.2 4 Q1 IRFB20N50K 20A/500V 47.2 65.9 5 D2 STTH8S06D 47.7 65.1 6 C5 100u/400V 105 18*25 KMG 41.1 58.8 7 L1 TR412 47.6 66.6 8 Q2 2SK4115 7A/900V 53.2 77.5 9 U1 FAN4800IN 48.7 66.1 10 T1 TF1926 80.4 97.0 11 D3 BYV26EG 1A/1KV 64.3 83.6 12 RG1 L7812CV 1.0A/12V 50.4 69.6 13 C201 47u/35V L6Kh 5*11 ZLH 52.5 77.9 14 L100 TR901 Ku106125-2 52.5 76.7 15 D101 STS30L30CT 59.3 75.7 16 C103 3900u/10V UL10Kh 12.5*25 ZLH 51.4 69.3 17 R10 3W 100Ω 5% MINI 79.7 99.6 2 OVER LOAD BURN-IN TEST 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 VAC O/:110 % LOAD I/: 230 VAC O/:100 % LOAD Ta= -30 TEST:OK TEST:OK 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 50 6 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave I/: 272 VAC O/:FULL LOAD Ta= 50 HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/: 230 VAC O/:FULL LOAD (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) TEST:OK + 0.01 %(0~50 ) TEST:OK Model: S-240-24 Test Report 4 / 6
240W Single Output with FC Function S-240 series SAFETY TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-FG: 1.5 KVAC/min I/-O/: 3.6 KVAC/min I/-FG: 1.8 KVAC/min I/-O/: I/-FG: 7.3 6.84 ma ma O/-FG: 0.5 KVAC/min O/-FG: 0.6 KVAC/min O/-FG: 5.54 ma 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-FG: 500VDC>100MΩ O/-FG:500VDC>100MΩ I/-O/: 500 VDC I/-FG: 500 VDC O/-FG: 500 VDC /70%RH I/-O/: 12 GΩ I/-FG: 3 GΩ O/-FG: 3.5 GΩ 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 4 AROVAL TUV: Certificate NO :R50159049 UL: File NO :E183223 40 A / 2min / 70%RH 8 mω E.M.C TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A CLASS D 2 CONDUCTION EN55022 CLASS B 3 RADIATION EN55022 CLASS B 4 E.S.D EN61000-4-2 LIGHT INDUSTRY AIR:8KV / Contact:4KV I/: 230 VAC/50HZ O/:FULL LOAD I/: 230 VAC (50HZ) O/:FULL/50% LOAD I/: 230 VAC (50HZ) O/:FULL LOAD I/: 230 VAC/50HZ O/:FULL LOAD ASS ASS Test by certified Lab ASS Test by certified Lab CRITERIA A 5 E.F.T EN61000-4-4 LIGHT INDUSTRY INUT: 1KV 6 SURGE IEC61000-4-5 LIGHT INDUSTRY L-N :1KV L,N-E:2KV I/: 230 VAC/50HZ O/:FULL LOAD I/: 230 VAC/50HZ O/:FULL LOAD CRITERIA A CRITERIA A 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LIFE CYCLE S-240-5:SUOSE C103 IS THE MOST CRITICAL COMONENT I/: 230VAC O/:FULL LOAD Ta= 25 LIFE TIME=498365.4 I/: 230VAC 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 284K HRS O/:FULL LOAD Ta=40 LIFE TIME=249128.4 HRS HRS Model: S-240-24 Test Report 5 / 6
240W Single Output with FC Function S-240 series COMONENT STRESS TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage Q2 Rated: 2SK4115 7A/900V 2 Diode eak Voltage D 100 Rated: 3 FC Transistor ( D to S) or (C to E) eak Voltage STS20120CT 20A/120V Q1 Rated: IRFB20N50K 20A/500V 4 Input Capacitor Voltage C 5 Rated: 100u/400V 105 18*25 KMG I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2)Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2)Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 828 V (2) 812 V (1) 88.4 V (2) 91 V (1) (2) 444 436 V V (1) 376 V (2) 377 V (3) 391 V 5 Control IC Voltage Test U 1 Rated: WM FAN4800IN 18V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 15.25 V (2) 15 V (3) 15.6 V DATE SAMLE TEST RESULT TESTER AROVAL 2009/6/5 RD SAMLE ASS SANFORD SU VINCENT TSENG 2009/7/28 RODUCT SAMLE W0907A36 ASS SANFORD SU VINCENT TSENG 2003/12/12 A50-F023 Model: S-240-24 Test Report 6 / 6