Dialight LED Lighting Catalogue - EMEA

Similar documents
SafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1 MDTEXSSFLX001_B

Vigilant LED High Bay - CE Technical Specifications

Vigilant LED High Bay Technical Specifications

SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications #

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas

DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications

SafeSite LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Applications

SafeSite. Series LED Based Signaling for Hazardous Locations

Product Guide LED OBSTRUCTION LIGHTS

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

SafeSite LED Floodlight - UL 844 for Indoor and Outdoor Hazardous Applications

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

Mini 300 LED gen2 Controlable, Manageable & Energy Efficient canopy lighting

ecostar ecostar Outdoor Spec Sheets 2013

CATALOG Interior I Exterior

BRAGI FUNCTIONAL LIGHT LINE FOR RETAIL, INDUSTRY AND WAREHOUSING

2015 LED LIGHTING PRODUCT GUIDE 3RD EDITION

SIGNAL. Product Data Sheet. LED Technology. Lighting Facts. Signal 24 AE-024L4-02F-40K. Signal 32 AE-032L3-04F-40K

Porcelain II - Bold and compact, the Porcelain II works well on its own or in a series, illuminating interiors with soft white light.

B-Series Switches Temperature Switches

High-performance LED Elbow spot

NEXT GENERATION SOLID STATE AND REMOTE PHOSPHOR LED Outdoor Lighting Solutions

Suitable for high ceiling delivering comfortable light

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

SIGN LIGHTING SOLUTIONS LED DRIVERS ELECTRONIC SIGN BALLASTS HID REPLACEMENT LED LAMPS

Application Corridors Staircases Entrance areas Restrooms Emergency exits Parking garages Outdoor safety lighting

DOT 9700P LED PERFORMANCE SERIES

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Applications. High Bay Fluorescent Product Guide. Visit us online at Howard.com or call us at

Specifications. Dimension (mm) 600*600 LED Panel 620*620 LED Panel 300*1200 LED Panel 600*1200 LED Panel 300*300 Panel Light 300*600 Panel Light

ARNE. Product Data Sheet ARNE. LED Technology. Flood Optics and Street Optics

Micro 1W Monochromatic Model No: MIC US

Emergency Stop Devices

Rio LINEAR PROFILE / OUTDOOR. DesignPlan: L&L Linear Profiles. No dark zone between fixtures. One piece co-extruded acrylic inner body

Advanced Customization Type 1. White Paper

WARNING DEVICES ATEX. V.le Rimembranze, Sesto S. G. (MI) ITALY Ph.: a.r. Fax:

12802 Commodity PL Tampa, FL Phone: Visit us at

11.0 W/FT (10.7 W/FT) lm/w OPTICAL SYSTEM Transparent acrylic: 8mm thickness, 4" H x 24", 36", 48", 96" OR 7.5" H x 24", 36", 48", 96"

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Media facade RGB LED lighting solution. Sustainable architectural LED lighting systems

WASHGUARD. More Than Just a Motor Company WASHDOWN DUTY PT PRODUCTS ELECTRIC MOTORS, GEAR REDUCERS, AC & DC DRIVES. Bulletin 1500

Outdoor. Decorative Luminaires

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Awnings ISSUE: AW Sec. : Awnings Date : Aug 2015

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

Kona Folding Arm Awnings. Product Information

2015/16 PROTECTING THE TOOLS OF YOUR LIVELIHOOD

FIBER OPTIC CLOSURES

ew Cove QLX Powercore

Big SHOT III Hybridization Oven

SEMI OUTDOOR TV ENCLOSURE PRODUCT OVERVIEW. Specifications and Detailed Product Overview

CENELEC SERIES. SXTB Page 2,3,4 EExe T6 IP66. ASTH Page 5,6,7,8. STH Page 9,10,11,12 EExd B T6 IP66. EXPLOSION PROOF TESTING EQUIPMENT Page 13,14

Trapped Key Transfer System SHGV SVM SVE

Model Number Structure

FOLDING ARM AWNINGS STYLISH DESIGNS EXCEPTIONAL STRENGTH

A flexible and affordable retail toolbox

The four elements of nature: Fire, Water Earth & Air

Conservatory awning W8 Description

Data Sheet for Precision Potentiometer

Data Sheet for Precision Potentiometer

General-Use Auto-Tuning HPX-T Series

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

4 Storage cupboards SCALA

Belisha Beacons Mains Powered, Aluminium Anti-Vandal Gallery & UV Stabilised Amber Globe

Extend your Lifestyle Conservatory Awnings Folding Arm Awnings Vertical Screens

DUAL COLOR, LOW-PROFILE

TOKISTAR. Exhibitor TOKISTAR LIGHTING

SPECIFICATIONS. Awnings. Sec. : Awnings Date : Dec 2017 ISSUE: AW

Woodhouse UK plc tel +44 (0) fax +44 (0)

SmartBright LED Downlight G3

Premium - Retractable Stand

Section 11 Workstation Components

Smallest Connector with Removable Contacts

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility

500 Watt Quartz Flood Light on Telescoping Tripod - Extends 3.5' to 10'

IB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display

General Purpose High Power PCB Relays

Ball Valve Manual Balance Hose Kits - Submittal

The International Range. 3 The Australian Barbeque. Why Choose A Lifestyle International Barbeque? Four Sizes To Suit All Requirements

code: NEWS _EN s/p LED 2016 NEWS 03 D U R A S T R I P -EN

LOOK OUT COLLISION AWARENESS. Our Products Alert Employees Of Dangerous Collisions BEFORE They Occur! LEADERS OF INTERSECTION PROTECTION

CADDY CORPORATION. Hot Food Caddys

Light Fittings & Accessories Tel: Fax:

GreenSpace. A high-efficiency sustainable LED solution

The four elements of nature: Fire, Water Earth & Air

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:

INDUSTRIAL DOORS

HEATER POWER CONTROLLER

OREON GROW LIGHT 2.2

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

A flexible and affordable retail toolbox

markilux 780 / 880 Remarkably compact yet strong conservatory awnings for small glass areas both on the interior and the exterior

Hammer, Discus, Shot Put, Javelin

Muskoka Folding Glass Wall System

CEL Belisha AVG Gallery CELstar LED Unit

ACCESSORIES OUR PARTS PUT YOU IN THE PASSING LANE. Yep, it's in here. AC1. velvac.com

Dry Ice Blasting Unit

Contego. Contego. Provided by: T.F: Awning BROCHURES. Showroom & Office: 105 Merritt Street, St Catharines L2T 1J7

Transcription:

Dialight LED Lighting Catalogue - EMEA for Industrial and Hazardous Areas March 2018

Cost-Effective Low maintenance integrated design, high efficiency, and an industry leading warranty equal significant time and cost savings. Sustainable A strategic focus on environmentally friendly LED technology and a commitment to helping all organizations, including our own, reach corporate sustainability goals. The Dialight Difference Convenient Fixtures deliberately designed with no field replacement parts for the lifespan of the fixture and easy retro-fit kits to make installation and maintenance turn-key. Safe Solutions designed for the world s most demanding industrial environments. Fully integrated designs and extensive testing ensure that you can count on our solutions every minute of the day. Intelligent Controlled lighting solutions that can seamlessly integrate with existing factory automation and building management systems to conveniently optimize work site safety and productivity. Trusted Deep expertise exclusively in LED lighting technology and decades of experience as a partner to many of the world s leading organizations has helped us achieve the largest installed base of industrial LED fixtures in the world. Dialight s Industry Leading 5, 7 and 10 Year Warranties At Dialight, we take great pride in the design and robust engineering of our products. We deeply understand the harsh environments that our customers depend on our fixtures to illuminate each day. That s why our fixtures are built specifically for longevity in these conditions. We are the only industrial LED lighting supplier with fully-integrated products built for industrial applications, featuring custom in-house power supplies designed for long-life with superior temperature tolerance, vibration resistance and built-in surge protection. Additionally, our sealed fixtures prevent moisture and contaminants from causing failures or reducing lifespan. We stand behind our industry leading warranties with proven real-world results in the world s most challenging environments and extensive quality control testing. Additionally, whilst some other manufacturers may require a minimum threshold of 10% or more of LED components to fail in order for a product to be defective, we do not require this because the safety and productivity of your work site is of paramount importance to us. If you would like to learn more about our warranties, please find the full warranty terms & conditions available on our website www.dialight.com 2 www.dialight.com

Before After About Dialight With over 80 years of industrial LED lighting experience and the largest installed base in the world, Dialight s extensive network of support staff, distributor and channel partners are ready to help you select among our wide range of products to identify a lighting solution that meets your specific needs. Vigilant LED lighting for general industrial applications 10 year warranty DuroSite LED lighting for general industrial applications 5 & 10 year warranty SafeSite LED lighting for hazardous area applications 5 & 10 year warranty www.dialight.com 3

Maintenance Comparison 10 years Typical non-dialight LED product High Pressure Sodium Fluorescent Metal Halide 4

Table of Contents Hazardous Area Ratings 12 Corrosion Protection and Coating Process 13 Vigilant LED Lighting for Industrial Applications Vigilant LED High Bay 14-19 Vigilant LED Low Bay 20-23 Vigilant LED High Bay - High Output 24-25 Vigilant LED Dual Floodlight 26-27 Vigilant LED Area Light 28-29 Vigilant LED Conveyor Light 30-31 DuroSite LED Lighting for Industrial Applications DuroSite LED Floodlight 32-33 DuroSite LED Linear - Low Profile 34-35 DuroSite LED Stainless Steel Linear, Emergency Model 36-37 DuroSite LED Bulkhead, Emergency Model 38-41 SafeSite LED Lighting for Hazardous Applications SafeSite LED High Bay 42-43 SafeSite LED Stainless Steel Linear, Emergency Model 44-45 SafeSite LED Area Light 46-47 SafeSite LED Bulkhead, Emergency Model 48-51 SafeSite LED Transportable Lighting for Hazardous Applications SafeSite LED Transportable High Bay 52 SafeSite LED Transportable Bulkhead 53 StreetSense LED Fixture for Infrastructure Solutions StreetSense LED Street Light - ATEX, IECEx 54-55 Obstruction LED Lighting ICAO 56-57 5

Overview Industrial Applications Vigilant LED Lighting Fixtures for Industrial Applications LED High Bay Wattage Range: 80-186W Lumen Output Range: 10,500-27,000 Lumens per Watt: Up to 145 Input Voltage: Mounting Height: 100-277 VAC, 120-250 VDC Overhead, Ceiling, Suspended Up to 12m LED High Bay - Wiring Box with Occupancy Sensor Wattage Range: 80-186W Lumen Output Range: 10,500-27,000 Lumens per Watt: Up to 145 Input Voltage: Mounting Height: 100-277 VAC, 120-250 VDC Overhead, Ceiling, Suspended, Wall Up to 12m Low Bay - Corded Models Wattage Range: 42-154W Lumen Output Range: 3,500-18,000lm Lumens per Watt: Up to 123 Input Voltage: Mounting Height: 100-277 VAC Overhead, Ceiling, Suspended, Wall Up to 7m Low Bay - Wiring Box with Occupancy Sensor Wattage Range: 42-154W Lumen Output Range: 3,500-18,000lm Lumens per Watt: Up to 123 Input Voltage: Mounting Height: 100-277 VAC Overhead, Ceiling, Suspended, Wall Up to 7m Low Bay - Integrated Wiring Box Wattage Range: 42-154W Lumen Output Range: 3,500-18,000lm Lumens per Watt: Up to 123 Input Voltage: Mounting Height: 100-277 VAC Overhead, Ceiling, Suspended, Wall Up to 7m 6 www.dialight.com

Overview Industrial Applications Vigilant LED Lighting Fixtures for Industrial Applications LED High Bay - High Output Wattage Range: 360-480W Lumen Output Range: 42,000-60,000 Lumens per Watt: Up to 125 Input Voltage: Mounting Height: 120-277 VAC Suspended Up to 30m LED Dual Floodlight Wattage Range: 385W Lumen Output Range: 54,000-56,000 Lumens per Watt: Up to 145 Input Voltage: Mounting Height: 120-277 VAC, 120-250 VDC Structure, Pole Up to 25m LED Area Light Wattage Range: 40-66W Lumen Output Range: 5,500-9,000 Lumens per Watt: Up to 143 Input Voltage: Mounting Height: 100-277 VAC, 120-250 VDC Ceiling, Wall, Pole Up to 10m LED Conveyor Light Wattage: 64W Lumen Output: 6,700 Lumens per Watt: Up to 106 Input Voltage: Mounting Height: 100-277VAC, 120-250 VDC 34mm pole mount Up to 6m www.dialight.com 7

Overview Industrial Applications DuroSite LED Lighting Fixtures for Industrial Applications LED Floodlight Wattage Range: 106-140W Lumen Output Range: 10,500-15,000 Lumens per Watt: Up to 111 Input Voltage: Mounting Height: 100-277 VAC Structure, Pole Up to 15m LED Linear - Low Profile Wattage Range: 33W-66W Lumen Output Range: 3,300-6,700 Lumens per Watt: Up to 102 Input Voltage: Mounting Height: 100-277 VAC Overhead, Wall Up to 6m LED Stainless Steel Linear & Emergency Battery Backup Wattage Range: 34W-76W (Standard), 35W-70W (Emergency) Lumen Output Range: 2,600-5,100 Lumens per Watt: Up to 76 Input Voltage: Mounting Height: 100-277 VAC (Standard), 230/240 VAC (Emergency) Overhead, Wall, Pole Up to 6m LED Bulkhead & LED Emergency Bulkhead Wattage Range: 34W (Standard), 36W (Emergency) Lumen Output Range: 2,250 Lumens per Watt: Up to 66 Input Voltage: Mounting Height: 100-277 VAC (Standard), 207-264 VAC (Emergency) Wall, Ceiling, Stanchion, Adjustable Up to 4m 8 www.dialight.com

Overview Hazardous Applications SafeSite LED Lighting Fixtures for Hazardous Area Applications LED High Bay - High Efficiency Wattage Range: 235W Lumen Output Range: 9,650-23,500 Lumens per Watt: Up to 110 Input Voltage: Mounting Height: 100-277 VAC Pole, Overhead, Ceiling, Wall Up to 12m Zone: Zone 1, 21 and Zone 2, 22 LED Linear & LED Emergency Linear - Stainless Steel Wattage Range: 34W-76W (Standard), 35W-70W (Emergency) Lumen Output Range: 2,600-5,100 Lumens per Watt: Up to 76 Input Voltage: Mounting Height: 110-250 VAC (Standard), 230-240 VAC (Emergency) Overhead, Ceiling, Wall, Pole Up to 6m Zone: Zone 1, 21 and Zone 2, 22 LED Area Light Wattage Range: 22-58W Lumen Output Range: 2,200-6,000 Lumens per Watt: Up to 109 Input Voltage: Mounting Height: 100-277 VAC Overhead, Ceiling, Wall, Pole Up to 10m Zone: Zone 1, 21 and Zone 2, 22 LED Bulkhead & LED Emergency Bulkhead Wattage Range: 34W (Standard), 36W (Emergency) Lumen Output Range: 2,250 Lumens per Watt: Up to 66 Input Voltage: Mounting Height: 100-277 VAC (Standard), 207-264 VAC (Emergency) Wall, Ceiling, Stanchion, Adjustable 4m and lower Zone: Zone 1, 21 and Zone 2, 22 www.dialight.com 9

Overview Industrial and Hazardous Applications SafeSite LED Transportable Range for Hazardous Area Applications SafeSite LED Transportable High Bay Wattage Range: 144W Lumen Output Range: 16,000 Lumens per Watt: Up to 110 Input Voltage: 100-277 VAC Zone: Zone 1, 21 and Zone 2, 22 SafeSite LED Transportable Bulkhead Wattage Range: 34W Lumen Output Range: 2,250 Lumens per Watt: Up to 66 Input Voltage: 100-277 VAC Zone: Zone 1, 21 and Zone 2, 22 StreetSense LED Street Light for Industrial and Hazardous Area Applications StreetSense LED Street Light - CE and ATEX Zone 2 Wattage Range: 65-252W Lumen Output Range: 5,500-20,250 Lumens per Watt: Up to 85 Input Voltage: 100-277 VAC Zone: Zone 2 10 www.dialight.com

Overview Industrial and Hazardous Applications Obstruction LED Lighting Solutions ICAO Vigilant LED Based ICAO Type A High Intensity (White / Red) Strobe Effective Intensity: Wattage: Input Voltage: White Day 200,000 cd White Twilight- 20,000 cd White or Red Night- 2,000 cd White day - 160W White twilight - 30W White Night - 23W Red Night - 30W 208-277 VAC Vigilant LED Based ICAO Type A/Type B Medium Intensity (White/Red) Strobe - Infrared (IR) available Effective Intensity: White Day- 20,000 cd White Night- 2,000 cd Red Night- 2,000 cd Wattage: White Day- 36W (system = 75W) White Night- 4W (system = 10W) Red Night- 12W (system = 25W) Input Voltage: 120-240 VAC or +/- 48 VDC Vigilant LED Based ICAO Type B/Type C Medium Intensity (Red) Beacon - Infrared (IR) available Effective Intensity: 2,000 cd Wattage: Input Voltage: 3.3W (16.7% duty circle)- standard 7.0W (16.7% duty circle)- IR model 20 flashes per minute with 0.5 sec. on time 120-240 VAC or 24-48 VDC Vigilant LED Based ICAO Type B/Type E Low Intensity (Red) RTO Side Light - Infrared (IR) available Effective Intensity: 32.5 cd Wattage Range: Input Voltage: 1.5-9.0W 12-48 VDC, 120-240 VAC, 277 VAC Vigilant LED Based ICAO Type B/Type E Low Intensity (Red) Side Light Effective Intensity: 32.5 cd Wattage Range: 13-24W Input Voltage: 12-48 VDC, 120 VAC, 230 VAC www.dialight.com 11

Hazardous Area Ratings Fixed and portable fixtures for installation and use in hazardous areas. Zones The zone defines the probability of hazardous material being present in an explosive concentration in the atmosphere. Zone Hazardous Material in Surrounding Atmosphere Zone 0, 20 Area in which an explosive gas / dust mixture is continuously present or present for long periods Zone 1, 21 Area in which an explosive gas / dust mixture is likely to occur for short periods in normal operation Zone 2, 22 Area in which an explosive gas / dust mixture is present for a very short time due to an abnormal condition Protection Types The protection types are used to denote the protection concept utilised in the devices. Ex Presence of Hazardous Material Zones Ex d Flameproof (Explosion proof) Enclosure 1, 21, 2, 22 Ex e Increased Safety 1, 21, 2, 22 Ex m Encapsulation 1, 21, 2, 22 Ex n or N Non incendive or/and normally no sparking circuits 2, 22 Temperature Ratings Certified equipment is tested for maximum temperature rating by approval agencies. Equipment for Group II receives a temperature code indicating the maximum temperatures of the product. Temperature Rating T1 450 C T2 300 C T3 200 C T4 135 C T5 100 C T6 85 C Groups (Gas & Dust) Equipment is tested for suitability in specified gas groups and dust groups. Gas groups IIA, IIB, IIC. Dust groups IIIA, IIIB, IIIC Group Hazardous Material in Surrounding Atmosphere Group IIA Propane group Group IIB Ethylene group Group IIC Hydrogen group Group IIIA Combustible flyings Group IIIB Non-conductive dust Group IIIC Conductive dust 12 www.dialight.com

Corrosion Protection and Coating Process Surface Preparation Industry-Standard Acid etch iron phosphate conversion Rinse Acid seal Dialight Proprietary alkaline etching Multiple reverse osmosis rinse removing calcium and minerals Proprietary surface conversion for chemical and mechanical bond to powder Final clean rinse using pure reverse osmosis water Industry standard product after 3000 hour Salt Spray Testing (ASTM B117) Industry standard product after 3000 hour Salt Spray Testing (ASTM B117) Powder Coat Industry-Standard Single layer hybrid epoxy - standard polyester powder coat Dialight (2 coats) 1st coat Epoxy primer base coat (much better bonding to the aluminium than polyester) 2nd coat Super durable polyester (better UV, chemical, salt and environmental resilience) www.dialight.com 13

Industrial Applications High Bay Vigilant LED High Bay Technical Specification Corded Model Wiring Box with Occupancy Sensor Integrated Wiring Box Mechanical Information: Fixture weight: 8.2 kg (18 lbs) Shipping weight: 10.9 kg (24 lbs) Stainless Steel Hook Power Cord: 3 meters, H07RN-F Heavy Duty Prefix: HEE Mechanical Information: Fixture weight: 9.9 kg (22 lbs) Shipping weight: 12.3 kg (27 lbs) Various Kits (see page 17) Wiring Box Cable Entries: M25 x 2 Terminals: 4mm 2 x 5 Prefix: HWE Mechanical Information: Fixture weight: 9.1 kg (20 lbs) Shipping weight: 11.8 kg (26 lbs) Various Kits (see page 17) Wiring Box Cable Entries: M25 x 3 Terminals: 4mm 2 x 5 Prefix: HWE Certifications & Ratings: EN 60598-1:2015 EN 60598-2-1 (ed.1), IEC 60598-2-1 (ed.8) EN 60598-2-24:2013 EN 62471:2008, EN 62778:2014 EN 62493:2015 IEC60068 Salt spray testing - severity 1 IP66 to EN 60529 Variable Dimming as Standard: Variable Dimming Control: 0-10 VDC Dimming Range: Occupancy Sensor: Mounting Height: Ingress Protection: Electrical Specifications: Operating Voltage: Total system power consumption: Operating Temp: IK10 to EN 50102 ( lens) IK06 to EN 50102 (Acrylic lens) IK05 to EN 50102 (Glass lens) D-Marking to EN 60598 2-24 ENEC L70 >150,000 hours @ 25 o C ambient 10 VDC = 100% light output 0 VDC = <5% light output Up to 12M IP66 100-277 VAC 120-250 VDC See table -40 C to +65 C Harmonics: IEC 61000-3-2 Noise requirement /EMC: EN 61547: 2009 Radiated and Conducted Emissions: EN 55015 EMC Immunity: EN 61547: 2009 Transient protection: THD: < 20% Power Factor: > 0.9 Construction: Housing: Finish: Lens: Photometric Information: CRI: 80 Protection devices capable of handling up to 10kV. Tested for 10kV/2 ohm combination wave, as per IEEE C62.41, line-line and line ground Copper-free aluminium Superior dual coat finish -Sealed polyester topcoat -Chemical-resistant epoxy primer See table Comparison Warranty L70 Dialight LED High Bay 10yr >150,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 CCT: 5000K (cool white) 4000K (neutral white) All values typical unless otherwise stated (tolerance +/- 10%) 14 www.dialight.com

Industrial Applications High Bay Vigilant LED High Bay Dimensional Drawings Corded Model with Hook Mount 14.3 [.56] 261 [10.3] 406 [16] Wiring Box with Occupancy Sensor 174 [6.9] 154 [6.1] 616 [24.3] 292 [11.5] 439 [17.3] Integrated Wiring Box 174 [6.9] 269 292 [10.6] [11.5] 154 [6.1] 499 [17.3] www.dialight.com 15

Industrial Applications High Bay Vigilant LED High Bay Beam Distribution & Accessories Medium Oval = 0 O = 90 O HBXW3-SSL-316M HBXW3-SSL-304M Stainless steel bracket HBXCAB48 48 long stainless steel safety rope (for use with safety bracket) HBXSBDK Sand blast kit (dome lens) HBXSBDL Sacrificial dome lens HBXW3-SSL-304FTM 304 stainless steel forward throw bracket HBXW3-SSL-316FTM 316 stainless steel forward throw bracket HBXSB Safety Tabs 316 stainless steel Includes 4 tabs HBXSBK Sand blast kit (flat lens) HBXSBL Sacrificial flat lens HBXW3 Powder-coated aluminium swivel bracket HBXGS Glare shield (internal use only, for use with flat lens) HBXFSIRREMOTE Remote for occupancy sensor HBXW3EUHOOK Swivel bracket with hanging hook 16 www.dialight.com

Industrial Applications High Bay Vigilant LED High Bay Ordering Information Integrated Wiring Box - comes standard with bracket HBXW3 Part Number Legacy Part Number Lumens Watts lm/w Voltage CCT CRI Lens Beam Distribution HWE7MC2EDANNGN HEEGMC4PNJNG 27,000 186 145 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HWE4MC2EDANNGN HEE2MC4PNJNG 26,000 186 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HWELMC2EDANNGN HEELMC4PNJNG 25,000 186 134 100-277 VAC, 120-250 VDC 5000K 80 Medium HWE7EC2EDANNGN HEEGEC4PNJNG 27,000 186 145 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HWE4EC2EDANNGN HEE2EC4PNJNG 26,000 186 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HWELEC2EDANNGN HEELEC4PNJNG 25,000 186 134 100-277 VAC, 120-250 VDC 5000K 80 Oval HWE7MC2CDANNGN HEEGMC4KNJNG 19,500 129 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HWE4MC2CDANNGN HEE2MC4KNJNG 18,750 129 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HWELMC2CDANNGN HEELMC4KNJNG 18,000 129 130 100-277 VAC, 120-250 VDC 5000K 80 Medium HWE7EC2CDANNGN HEEGEC4KNJNG 18,000 129 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HWE4EC2CDANNGN HEE2EC4KNJNG 17,250 129 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HWELEC2CDANNGN HEELEC4KNJNG 16,750 129 130 100-277 VAC, 120-250 VDC 5000K 80 Oval HWE7MC2BDANNGN HEEGMC4GNJNG 14,250 102 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HWE4MC2BDANNGN HEE2MC4GNJNG 13,750 102 135 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HWELMC2BDANNGN HEELMC4GNJNG 13,500 102 132 100-277 VAC, 120-250 VDC 5000K 80 Medium HWE7EC2BDANNGN HEEGEC4GNJNG 14,250 102 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HWE4EC2BDANNGN HEE2EC4GNJNG 13,750 102 135 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HWELEC2BDANNGN HEELEC4GNJNG 13,500 102 132 100-277 VAC, 120-250 VDC 5000K 80 Oval HWE7MC2ADANNGN HEEGMC4DNJNG 11,250 80 141 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HWE4MC2ADANNGN HEE2MC4DNJNG 10,750 80 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HWELMC2ADANNGN HEELMC4DNJNG 10,500 80 131 100-277 VAC, 120-250 VDC 5000K 80 Medium HWE7EC2ADANNGN HEEGEC4DNJNG 11,250 80 141 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HWE4EC2ADANNGN HEE2EC4DNJNG 10,750 80 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HWELEC2ADANNGN HEELEC4DNJNG 10,500 80 131 100-277 VAC, 120-250 VDC 5000K 80 Oval Notes Note 1: Models in chart above are 5000K CCT. For 4000K CCT change the 6th character from C to N & deduct 3% from the lumen table. Note 2: Models with integrated wiring box are upgradeable to DALI & Wireless controls. Consult local Dialight sales office for availability. Note 3: Flat clear acrylic lens available, consult local Dialight sales office for availability. www.dialight.com 17

Industrial Applications High Bay Vigilant LED High Bay Ordering Information Standard model with 3 Meter Cable & Hook Mount Part Number Legacy Part Number Lumens Watts lm/w Voltage CCT CRI Lens Beam Distribution HEE7MC2EDHWNGN HEEGMC4PNHNG 27,000 186 145 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HEE4MC2EDHWNGN HEE2MC4PNHNG 26,000 186 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HEELMC2EDHWNGN HEELMC4PNHNG 25,000 186 134 100-277 VAC, 120-250 VDC 5000K 80 Medium HEE7EC2EDHWNGN HEEGEC4PNHNG 27,000 186 145 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HEE4EC2EDHWNGN HEE2EC4PNHNG 26,000 186 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HEELEC2EDHWNGN HEELEC4PNHNG 25,000 186 134 100-277 VAC, 120-250 VDC 5000K 80 Oval HEE7MC2CDHWNGN HEEGMC4KNHNG 18,000 129 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HEE4MC2CDHWNGN HEE2MC4KNHNG 17,250 129 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HEELMC2CDHWNGN HEELMC4KNHNG 16,750 129 130 100-277 VAC, 120-250 VDC 5000K 80 Medium HEE7EC2CDHWNGN HEEGEC4KNHNG 18,000 129 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HEE4EC2CDHWNGN HEE2EC4KNHNG 17,250 129 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HEELEC2CDHWNGN HEELEC4KNHNG 16,750 129 130 100-277 VAC, 120-250 VDC 5000K 80 Oval HEE7MC2BDHWNGN HEEGMC4GNHNG 14,250 102 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HEE4MC2BDHWNGN HEE2MC4GNHNG 13,750 102 135 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HEELMC2BDHWNGN HEELMC4GNHNG 13,500 102 132 100-277 VAC, 120-250 VDC 5000K 80 Medium HEE7EC2BDHWNGN HEEGEC4GNHNG 14,250 102 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HEE4EC2BDHWNGN HEE2EC4GNHNG 13,750 102 135 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HEELEC2BDHWNGN HEELEC4GNHNG 13,500 102 132 100-277 VAC, 120-250 VDC 5000K 80 Oval HEE7MC2ADHWNGN HEEGMC4DNHNG 11,250 80 141 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HEE4MC2ADHWNGN HEE2MC4DNHNG 10,750 80 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HEELMC2ADHWNGN HEELMC4DNHNG 10,500 80 131 100-277 VAC, 120-250 VDC 5000K 80 Medium HEE7EC2ADHWNGN HEEGEC4DNHNG 11,250 80 141 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HEE4EC2ADHWNGN HEE2EC4DNHNG 10,750 80 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HEELEC2ADHWNGN HEELEC4DNHNG 10,500 80 131 100-277 VAC, 120-250 VDC 5000K 80 Oval Notes Note 1: Models in chart above are 5000K CCT. For 4000K CCT change the 6th character from C to N & deduct 3% from the lumen table. Note 2: Flat clear acrylic lens available, consult local Dialight sales office for availability. 18 www.dialight.com

Industrial Applications High Bay Vigilant LED High Bay Ordering Information Occupancy Sensor Models - comes standard with bracket HBXW3 Part Number Legacy Part Number Lumens Watts lm/w Voltage CCT CRI Lens Beam Distribution HWE7MC2EMANNGN HEEGMC4PKJNG 27,000 186 145 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HWE4MC2EMANNGN HEE2MC4PKJNG 26,000 186 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HWELMC2EMANNGN HEELMC4PKJNG 25,000 186 134 100-277 VAC, 120-250 VDC 5000K 80 Medium HWE7EC2EMANNGN HEEGEC4PKJNG 27,000 186 145 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HWE4EC2EMANNGN HEE2EC4PKJNG 26,000 186 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HWELEC2EMANNGN HEELEC4PKJNG 25,000 186 134 100-277 VAC, 120-250 VDC 5000K 80 Oval HWE7MC2CMANNGN HEEGMC4KKJNG 19,500 129 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HWE4MC2CMANNGN HEE2MC4KKJNG 18,750 129 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HWELMC2CMANNGN HEELMC4KKJNG 18,000 129 130 100-277 VAC, 120-250 VDC 5000K 80 Medium HWE7EC2CMANNGN HEEGEC4KKJNG 18,000 129 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HWE4EC2CMANNGN HEE2EC4KKJNG 17,250 129 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HWELEC2CMANNGN HEELEC4KKJNG 16,750 129 130 100-277 VAC, 120-250 VDC 5000K 80 Oval HWE7MC2BMANNGN HEEGMC4GKJNG 14,250 102 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HWE4MC2BMANNGN HEE2MC4GKJNG 13,750 102 135 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HWELMC2BMANNGN HEELMC4GKJNG 13,500 102 132 100-277 VAC, 120-250 VDC 5000K 80 Medium HWE7EC2BMANNGN HEEGEC4GKJNG 14,250 102 140 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HWE4EC2BMANNGN HEE2EC4GKJNG 13,750 102 135 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HWELEC2BMANNGN HEELEC4GKJNG 13,500 102 132 100-277 VAC, 120-250 VDC 5000K 80 Oval HWE7MC2AMANNGN HEEGMC4DKJNG 11,250 80 141 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Medium HWE4MC2AMANNGN HEE2MC4DKJNG 10,750 80 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Medium HWELMC2AMANNGN HEELMC4DKJNG 10,500 80 131 100-277 VAC, 120-250 VDC 5000K 80 Medium HWE7EC2AMANNGN HEEGEC4DKJNG 11,250 80 141 100-277 VAC, 120-250 VDC 5000K 80 Clear Glass Oval HWE4EC2AMANNGN HEE2EC4DKJNG 10,750 80 134 100-277 VAC, 120-250 VDC 5000K 80 Clear Oval HWELEC2AMANNGN HEELEC4DKJNG 10,500 80 131 100-277 VAC, 120-250 VDC 5000K 80 Oval Notes Note 1: Models in chart above are 5000K CCT. For 4000K CCT change the 6th character from C to N & deduct 3% from the lumen table. Note 2: Models with integrated wiring box are upgradeable to DALI & Wireless controls. Consult local Dialight sales office for availability. Note 3: Flat clear acrylic lens available, consult local Dialight sales office for availability. www.dialight.com 19

Industrial Applications Low Bay Vigilant LED Low Bay Technical Specifications Corded Models Mechanical Information: Fixture weight: 8.2 kg (18 lbs) Shipping weight: 10.9 kg (24 lbs) Stainless Steel Hook Power Cord: 3 meters, H07RN-F Heavy Duty Prefix: LEE Certifications & Ratings: EN 60598:2015 EN 60598-2-1 (ed.1), IEC 60598-2-1 (ed.8) EN 60598-2-24:2013 EN 62471:2008, EN 62778:2014 EN 62493:2010 IEC60068 Salt spray testing - severity 1 Variable Dimming as Standard: Variable Dimming Control: 0-10 VDC IP66 to EN 60529 IK10 to EN 50102 ( lens) IK06 to EN 50102 (Acrylic lens) IK05 to EN 50102 (Glass lens) D-Marking to EN 60598 2-2 ENEC L70 >150,00 hours @ 25 o C ambient Low Bay Wiring Box with Occupancy Sensor Integrated Wiring Box Mechanical Information: Fixture weight: 9.9 kg (22 lbs) Shipping weight: 12.3 kg (27 lbs) Hook Wiring Box Cable Entries: M25 x 2 Terminals: 4mm 2 x 5 Prefix: LWE Mechanical Information: Fixture weight: 9.1 kg (20 lbs) Shipping weight: 11.8 kg (26 lbs) Various Kits (see page 17) Wiring Box Cable Entries: M25 x 3 Terminals: 4mm 2 x 5 Prefix: LWE Comparison Warranty L70 Dialight LED Low Bay 10yr >150,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 Dimming Range: Electrical specifications: Operating Voltage: Total system power consumption: Operating Temp: 10 VDC = 100% light output 0 VDC = <5% light output 100-277 VAC, 50/60 Hz 120-250 VDC See table -40 C to +65 C Harmonics: IEC 61000-3-2 Noise requirement /EMC: EN 61547: 2009 Radiated and Conducted Emissions: EN 55015 EMC Immunity: EN 61547: 2009 Transient protection: THD: < 20% Power Factor: > 0.9 Construction: Housing: Finish: Lens: Photometric Information: CRI: 80 CCT: Protection devices capable of handling up to 10kV. Tested for 10kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground Copper-free aluminium Superior dual coat finish -Sealed polyester topcoat -Chemical-resistant epoxy primer See table 5000K (cool white) 4000K (neutral white) All values typical unless otherwise stated (tolerance +/- 10%) 20 www.dialight.com

Industrial Applications Low Bay Vigilant LED Low Bay Dimensional Drawings Corded Models with Hook Mount 14.3 [.56] 261 [10.3] 406 [16.0] Wiring Box with Occupancy Sensor 174 [6.9] 616 [24.2] 154 [6.1] 373 [14.7] 439 [17.3] Integrated Wiring Box 174 [6.9] 154 [6.1] 373 [14.7] 439 [17.3] www.dialight.com 21

Industrial Applications Low Bay Vigilant LED Low Bay Mounting Accessories & Beam Distribution HBXW3-SSL-316M HBXW3-SSL-304M Stainless steel bracket HBXCAB48 1.21M long stainless steel safety rope (for use with safety bracket) HBXW3-SSL-304FTM 304 stainless steel forward throw bracket HBXW3-SSL-316FTM 316 stainless steel forward throw bracket HBXSB 316 stainless steel Includes 4 tabs HBXW3 Powder-coated aluminium swivel bracket HBXFSIRREMOTE Remote for occupancy sensor HBXW3EUHOOK Swivel bracket with hanging hook Ultra Wide = 0 O = 90 O 22 www.dialight.com

Industrial Applications Low Bay Vigilant LED Low Bay Ordering Information Part Number Legacy Part Number Lumens Watts lm/w Voltage CCT CRI Lens Beam Distribution Standard Models with 3m Cable & Hook Mount LEELUC2CDHWNGN 18,000 154 117 100-277 VAC, 120-250 VDC 5000K 80 LEELUC2BDHWNGN 14,000 114 123 100-277 VAC, 120-250 VDC 5000K 80 LEELUC29DHWNGN 9,000 80 122 100-277 VAC, 120-250 VDC 5000K 80 LEELUC26DHWNGN LBW1C1DEUH 6,000 56 116 100-277 VAC, 120-250 VDC 5000K 80 LEELUC24DHWNGN LBW1C5AEUH 4,000 42 101 100-277 VAC, 120-250 VDC 5000K 80 Integrated Wiring Box - comes standard with bracket HBXW3 LWELUC2CDANNGN 18,000 154 117 100-277 VAC, 120-250 VDC 5000K 80 LWELUC2BDANNGN 14,000 114 123 100-277 VAC, 120-250 VDC 5000K 80 LWELUC29DANNGN 9,750 80 122 100-277 VAC, 120-250 VDC 5000K 80 LWELUC26DANNGN 6,500 56 116 100-277 VAC, 120-250 VDC 5000K 80 LWELUC24DANNGN 4,250 42 101 100-277 VAC, 120-250 VDC 5000K 80 Integrated Wiring Box with Occupancy Sensor LWELUC2CMANNGN 18,000 154 117 100-277 VAC, 120-250 VDC 5000K 80 LWELUC2BMANNGN 14,000 114 123 100-277 VAC, 120-250 VDC 5000K 80 LWELUC29MANNGN 9,750 80 122 100-277 VAC, 120-250 VDC 5000K 80 LWELUC26MANNGN 6,500 56 116 100-277 VAC, 120-250 VDC 5000K 80 LWELUC24MANNGN 4,250 42 101 100-277 VAC, 120-250 VDC 5000K 80 Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Ultra Wide Notes Note 1: Models in chart above are 5000K CCT. For 4000K CCT change the 6th character from C to N & deduct 3% from the lumen table. Note 2: Models with integrated wiring box are upgradeable to DALI & Wireless controls. Consult local Dialight sales office for availability. www.dialight.com 23

Industrial Applications High Bay Vigilant LED High Bay - High Output Technical Specifications 10 year warranty Ratings and Certifications L70 >125,000 hours @ 25 o C ambient CE IP66 IK05 (glass and acrylic lens) 0-10V dimming as standard *All features not available on every model. Please refer to product part number pages for model specifics. Fixture weight: Mechanical Information 26.8 kg (59 lbs) Shipping weight: 33.1 kg (73 lbs) *Note: Wire box installed separately from housing Cable Entry: M25 x 4 Terminals: 4mm 2 x 6 Hook mount 316 Stainless steel Voltage options: Specifications 120-277 VAC Housing: Copper-free aluminium 415 VAC (consult sales) Finish: Operating temp: -40 C to +65 C Lens: See Table Power factor: >0.9 CRI: 80 Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy prime THD: <20% CCT: 5000K (cool white) Surge protection: 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground 4000K (neutral white) Comparison Warranty L70 Dialight LED High Bay 10yr >125,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 Lumens Wattage lm/w Mounting Heights 60,000 480 125 Up to 30m 45,000 360 125 Up to 20m Dimensions Dimensions in mm [inches] Beam Distribution Narrow Medium 24 www.dialight.com

Industrial Applications High Bay Vigilant LED High Bay - High Output Ordering Information & Mounting Accessories Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Distribution Standard Models - 120-277 VAC H6EGMC44D-HNNG 60,000 480 125 120-277 VAC 5000K (cool white) Tempered glass Medium H6EGNC44D-HNNG 60,000 480 125 120-277 VAC 5000K (cool white) Tempered glass Narrow H6EGMC4WD-HNNG 45,000 360 125 120-277 VAC 5000K (cool white) Tempered glass Medium H6EGNC4WD-HNNG 45,000 360 125 120-277 VAC 5000K (cool white) Tempered glass Narrow All values typical unless otherwise stated (tolerance +/- 10%). 415 VAC options available, please consult local Dialight sales office for availability. Acrylic and polycarbonate lens options available on made-to-order basis, please consult local Dialight sales office for availability. H6XCAB72 1.8M stainless steel safety rope Mounting Options Wiring Box Top Hat Hinge www.dialight.com 25

Industrial Applications Floodlight Vigilant LED Dual Floodlight Technical Specifications 10 year warranty CE IP66 Ratings and Certifications L70 >150,000 hours @ 25 C ambient Glass = IK05 = IK10 *All features not available on every model. Please refer to product part number pages for model specifics. Fixture weight: Mechanical Information 25.4 kg (56 lbs) Shipping weight: 27.2 kg (60 lbs) EPA (sq.m): Entries: M20 x 2 Terminals: 4mm 2 x 4 0.25 sq. m (2.69 sq. ft) 304 stainless steel trunnion mounting bracket included Voltage: 120-277 VAC, 50/60Hz 120-250 VDC Specifications Housing: Operating temp: -40 C to +65 C Finish: Copper-free aluminium Power factor: >0.9 Lens: Tempered glass THD: <20% CRI: 80 CCT: Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy primer 5000K (cool white) Comparison Warranty L70 Dialight LED Floodlight 10yr >150,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 Lumens Wattage lm/w Mounting Heights 56,000 385 145 Up to 25m 54,000 385 140 Dimensions Dimension in mm [inches] Beam Distribution 92 o Beam Angle 35 o Beam Angle 26 www.dialight.com

Industrial Applications Floodlight Vigilant LED Dual Floodlight Ordering Information & Mounting Accessories Part Number Fixture Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Angle Field Angle FLEB66MC2NG 56,000 385 145 120-277 VAC, 120-250 VDC 5000K (cool white) Tempered Glass 35 108 FLEBM0MC2NG 54,000 385 140 120-277 VAC, 120-250 VDC 5000K (cool white) Tempered Glass 92 120 All values typical unless otherwise stated (tolerance +/- 10%). HZXCBL2 Stainless steel safety cable kit Dual Floodlight Mounting Options Factory-Installed Mounting Bracket Dimensions Dimension in mm [inches] www.dialight.com 27

Industrial Applications Area Light Vigilant LED Area Light Technical Specifications 10 year warranty Ratings and Certifications L70 >300,000 hours @ 65 C ambient CE/ENEC IP66/67 IK07 (glass lens) / IK10 (polycarbonate lens) *All features not available on every model. Please refer to product part number pages for model specifics. Mechanical Information Fixture weight: 5.2 kg (11.5 lbs) Shipping weight: 6.1 kg (13.5 lbs) Cable Entries: M20 x 2 316 Stainless steel mounting bracket Terminals: 4mm 2 x 5 Specifications Voltage: 100-277 VAC 50/60Hz, 120-250 VDC Housing: Copper-free aluminium Operating temp: -40 C to +65 C Finish: Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy primer Power factor: >0.9 Lens: THD: <20% Tempered Glass Surge protection: 6kV / 3kA combination wave, as per IEEE C62.41, line-line and line-ground CRI: 80 CCT: 5000K (cool white) Comparison Warranty L70 Dialight LED Area Light 10yr >300,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 Lumens Wattage lm/w Mounting Heights 9,000 66 136 10m 7,300 52 140 5,700 40 143 3m -- 213 [8.4] 94 [3.7J Dimensions 2x M20xl. 202 l [8.0] 7 7 [3.0 J 3 0 I [11.8J ----2 7 2 [10.7 J I [ ---3 0 I [ 11.8 J Dimension in mm [inches] 28 www.dialight.com

Industrial Applications Area Light Vigilant LED Area Light Ordering Information Part Number Legacy Part Number Lumens Wattage lm/w Colour Temperature (CCT) Lens Beam Angle Mounting Options Hardware Accessories CE with Junction Box ALE7AC26DBJUGN STJW8C2GEU 5500 40 138 5000K (cool white) Glass 180 ALE7AC27DBJUGN STJWEC2GEU 7100 52 137 5000K (cool white) Glass 180 ALE7AC29DBJUGN 8800 66 133 5000K (cool white) Glass 180 ALE7BC26DBJUGN STJW9C2GEU 5700 40 143 5000K (cool white) Glass 360 ALE7BC27DBJUGN STJWFC2GEU 7300 52 140 5000K (cool white) Glass 360 ALE7BC29DBJUGN 9000 66 136 5000K (cool white) Glass 360 All values typical unless otherwise stated (tolerance +/- 10%). Neutral white option available, please consult local Dialight sales office for availability. 3m cable gland lead options available on made-to-order basis, please consult local Dialight sales office for availability. 316 stainless steel adjustable bracket 316 stainless steel adjustable bracket 316 stainless steel adjustable bracket 316 stainless steel adjustable bracket 316 stainless steel adjustable bracket 316 stainless steel adjustable bracket Junction box Junction box Junction box Junction box Junction box Junction box Beam Distribution 180 Beam Angle 360 Beam Angle Factory-Installed Mounting Bracket Dimensions Dimension in mm [inches] www.dialight.com 29

Industrial Application Area Light Vigilant LED Conveyor Light Technical Specifications 10 year warranty Ratings and Certifications L70 >300,000 hours @ 65 C ambient CE/ENEC IP66/67 IK10 (polycarbonate lens) *All features not available on every model. Please refer to product part number pages for model specifics. Fixture weight: Shipping weight: Cable Entries: Mechanical Information 6.8 kg (15 lbs) 7.7 kg (17 lbs) 34mm slip-fit stanchion mount M25 x 1 rear Terminals: 4mm 2 x 5 Specifications Voltage options: 100-277 VAC 50/60Hz, 120-250 VDC Housing: Copper-free aluminium Operating temp: -40 C to +65 C Finish: Power factor: >0.9 Lens: THD: <20% CRI: 80 Surge protection: 6kV / 3kA combination wave, as per IEEE C62.41, line-line and line-ground CCT: Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy prime 5000K (cool white) Comparison Warranty L70 Dialight LED Conveyor Light 10yr >300,000 High Pressure Sodium 1 24,000 Metal Halide 1 15,000 Lumens Wattage lm/w Mounting Heights 6700 64 105 Up to 6m Dimensions Beam Distribution Dimension in mm [inches] Wide Mounting Options 34 mm Slip-Fit Stanchion Mount Junction Box 30 www.dialight.com

Industrial Application Area Light Vigilant LED Conveyor Light Ordering Information Part Number Lens Material Beam Distribution CCT CRI Lumens Wattage lm/w Mounting Options ALE5WC27DYNUGN Wide 5000K 80 6,700 64 106 34mm slip-fit adapter All values typical unless otherwise stated (tolerance +/- 10%). Neutral white option available, please consult local Dialight sales office for availability. Spacing Table 6,700 fixture light levels Mounting height - 3m Spacing - 8m Average illuminance - 112 lux Light loss factor - 0.85 6,700 fixture light levels Mounting height - 3m Spacing - 12m Average illuminance - 78 lux Light loss factor - 0.85 6,700 fixture light levels Mounting height - 3m Spacing - 15m Average illuminance - 65 lux Light loss factor - 0.85 Mounting Options Dialight Luminaire Conveyor Light Wall Mount with Pole Adapter Conveyor Light Spacing 3m Installed Height www.dialight.com 31

Industrial Application Floodlight DuroSite LED Floodlight Technical Specifications 10 year warranty Ratings and Certifications L70 >150,000 hours @ 25 C ambient CE IP66/67 IK07 (glass lens), IK10 (polycarbonate lens) *All features not available on every model. Please refer to product part number pages for model specifics. Fixture weight: Mechanical Information 13,500-15,000 lm: 13.6 kg (30 lbs) 10,750-11,500 lm: 12.2 kg (27 lbs) Shipping weight: 13,500-15,000 lm: 15.4 kg (30 lbs) 10,750-11,500 lm: 14.1 kg (31 lbs) EPA (sq.m) 0.05 sq. m (0.55 sq. ft) Cable Entry: M20 x 2 304 Stainless steel trunnion mounting bracket included Specifications Voltage options: 100-277 VAC, 50/60Hz Housing: Die cast aluminium Operating temp: -40 C to +65 C Finish: Power factor: >0.9 Lens: THD: <20% CRI: 75 Surge protection: 6kV line-to-line, 6kV lineto-ground CCT: Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy prime Tempered glass 5000K (cool white) Terminals: 4mm 2 x 3 Dimensions Lumens Wattage lm/w Mounting Heights 15,000 135 111 15m 14,750 135 109 14,500 140 104 13,500 140 96 11,500 106 108 11,250 106 106 11,000 106 104 10,750 106 101 10,500 106 99 Dimension in mm [inches] Comparison Warranty L70 Dialight LED Floodlight 10yr >150,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 Beam Distribution Field Angle = 140 x 115 Field Angle = 115 x 140 Field Angle = 115 Field Angle = 93 Field Angle = 52 Field Angle = 23 32 www.dialight.com

Industrial Application Floodlight DuroSite LED Floodlight Ordering Information & Mounting Accessories Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Description FLE466MC4NG 15,000 135 111 100-277 VAC 5000K (cool white) Tempered glass Medium (57 ) FLE476MC4NG 14,750 135 109 100-277 VAC 5000K (cool white) Tempered glass Wide Oval (105 x 70 ) FLE467MC4NG 14,750 135 109 100-277 VAC 5000K (cool white) Tempered glass Medium Wide (70 x 105 ) FLE455MC4NG 14,500 140 104 100-277 VAC 5000K (cool white) Tempered glass Medium (45 ) FLE444MC4NG 14,500 140 104 100-277 VAC 5000K (cool white) Tempered glass Medium Narrow (27 ) FLE422MC4NG 13,500 140 96 100-277 VAC 5000K (cool white) Tempered glass Very Narrow (12 ) FLE276MC2NG 11,500 106 108 100-277 VAC 5000K (cool white) Tempered glass Wide Oval (105 x 70 ) FLE266MC2NG 11,250 106 106 100-277 VAC 5000K (cool white) Tempered glass Medium (57 ) FLE255MC2NG 11,000 106 104 100-277 VAC 5000K (cool white) Tempered glass Medium (45 ) FLE244MC2NG 10,500 106 99 100-277 VAC 5000K (cool white) Tempered glass Medium Narrow (27 ) FLE222MC2NG 10,750 106 101 100-277 VAC 5000K (cool white) Tempered glass Very Narrow (12 ) All values typical unless otherwise stated (tolerance +/- 10%). lens available, please consult local Dialight sales office for availability. HZXSAFECBLS Stainless steel safety cable kit Factory-Installed Mounting Bracket Dimensions Dimension in mm [inches] www.dialight.com 33

Industrial Application Linear DuroSite LED Linear - Low Profile Technical Specifications 5 year warranty Ratings and Certifications L70 >100,000 hours @ 25 C ambient CE IP66/67 IK07 *All features not available on every model. Please refer to product part number pages for model specifics. Mechanical Information Fixture weight: 1.2 m: 5.9 kg (13 lbs) 0.6 m: 4.5 kg (10 lbs) Shipping weight: 1.2m: 0.6m: 8.2 kg (18 lbs) 6.8 kg (15 lbs) Cable Entries: M25 x 4 Factory-installed 316 Stainless steel swivel bracket - (LPXW4) Specifications Voltage options: 100-277 VAC Housing: Copper-free aluminium Operating temp: -40 C to +65 C Finish: Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy prime Power factor: >0.9 Lens: Diffused THD: <20% CRI: 70 Surge protection: EN 61000-4-5 4kV line-to-line, 4kV line-to-ground CCT: 5000K (cool white) Terminals: 2.5mm 2 x 3 Comparison Warranty L70 Dialight LED Linear 5yr >100,000 Fluorescent 1 24,000 Lumens Wattage lm/w Mounting Heights 6,700 66 102 6m 3,300 33 100 3m Dimensions Beam Distribution Dimension in mm [inches] Medium Pattern Mounting Options Side Mount - LPXW4 (included) Top Mount - LPXW4 (included) 34 www.dialight.com

Industrial Application Linear DuroSite LED Linear - Low Profile Ordering Information & Mounting Accessories Part Number Lumens Wattage lm/w Length Voltage Colour Temperature Lens Beam Distribution LPE3C4B2W 3,300 33 100 0.6m 100-277 VAC 5000K (cool white) Diffused polycarbonate Medium LPE3C4H2W 6,700 66 102 1.2m 100-277 VAC 5000K (cool white) Diffused polycarbonate Medium All values typical unless otherwise stated (tolerance +/- 10%). LPXW4LP 316 Stainless steel low profile mounting bracket, can be angled at 0 and 15 LPXW4 (included) 316 Stainless steel mounting bracket, can be angled at 0, 30, 45, 60, & 90 LTXENDCAPKIT 304 Stainless steel chain mount and secondary retention bracket LTXSAFEKIT Stainless steel safety cable kit for secondary retention LPXW4 Mounting Bracket Dimensions Dimension are in mm [inches] www.dialight.com 35

Industrial Application Linear DuroSite LED Stainless Steel Linear Technical Specifications 5 year warranty Ratings and Certifications L70 >150,000 hours @ 25 C ambient CE IP66/67 IK09 *All features not available on every model. Please refer to product part number pages for model specifics. Emergency options available, please consult your local Dialight sales office. Fixture weight: Shipping weight: Entry: Mechanical Information Standard: 1308mm - 11.3 kg (25 lbs) 708mm - 6.8 kg (15 lbs) Emergency: 1450mm - 14.1 kg (31 lbs) 850mm - 9.1 kg (20 lbs) Standard: 1308mm - 14.1 kg (31 lbs) 708mm - 9.1 kg (20 lbs) Emergency: 1450mm - 17.2 kg (38 lbs) 850mm - 11.3 kg (25 lbs) (2) M8 fixing points Terminals: 4mm 2 x 7 M25 x 2 cable entries at both ends, through wired as standard. M20 options - consult sales Voltage options: Operating temp: Power factor: Specifications Standard: 100-277 VAC Housing: 316 Marine grade stainless steel Emergency: 230, 240 VAC Lens: Standard: -20 C to +60 C CRI: 70 Emergency: -20 C to +60 C >0.9 CCT: Surge protection: Emergency Models High impact resistant diffused polycarbonate 5000K (cool white) 4000K (neutral white) EN 61000-4-5 1kV line-to-line, 2kV line-to-ground Battery: 3.6V 10Ah NiMH Duration: @ 25 C ambient - est. >3 hours Expected battery life: 4 years Comparison Warranty L70 Dialight LED Linear 5yr >150,000 Fluorescent 1 24,000 Standard Model Dimensions Lumens Wattage lm/w Mounting Heights 5,100 67 80 6m 2,600 34 86 3m Emergency Model Dimensions Dimension in mm Beam Distribution Medium 36 www.dialight.com

Industrial Application Linear DuroSite LED Stainless Steel Linear Ordering Information & Mounting Accessories Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Distribution Standard Model - 100-277 VAC EL-1C6R-SSCB4 5,100 67 76 100-277 VAC 5000K (cool white) Medium EL-1C6M-SSCB4 2,600 34 76 100-277 VAC 5000K (cool white) Medium Emergency Model - 230-240 VAC ELE-2C7R-SSCB4 5,100 70 73 230-240 VAC 5000K (cool white) Medium ELE-2C7M-SSCB4 2,600 35 74 230-240 VAC 5000K (cool white) Medium All values typical unless otherwise stated (tolerance +/- 10%). M20 cable entry options available, please consult local Dialight sales office for availability. Neutral white options available, please consult local Dialight sales office for availability. ELXCMBSS 316 Marine Grade Stainless steel ceiling mount kit ELXPCSS42 40-45mm range 316 Marine Grade Stainless steel pole clamp ELXWMBSS30 30 316 Marine Grade Stainless steel wall mount kit ELXEYESS 316 Marine Grade Stainless steel eyelet kit ELX-BATT-KIT 3.6V NiMH battery kit ELXPCSS47 47-51mm range 316 Marine Grade Stainless steel pole clamp ELXPCSS54 54-57mm range 316 Marine Grade Stainless steel pole clamp ELXPCSS59 59-62mm range 316 Marine Grade Stainless steel pole clamp ELXWMBSS45 45 316 Marine Grade Stainless steel wall mount kit ELXWMBSS60 60 316 Marine Grade tainless steel wall mount kit ELXWMBSS90 90 316 Marine Grade Stainless steel wall mount kit Mounting Options Wall Mount Bracket 30 Wall Mount Bracket 45 Wall Mount Bracket 60 Wall Mount Bracket 90 www.dialight.com Pole Clamp Ceiling Mount Eyelet 37

Industrial Application Bulkhead DuroSite LED Bulkhead Technical Specifications 5 year warranty Ratings and Certifications L70 >100,000 hours @ 25 C ambient CE IP66/67 Emergency models available IK08 *All features not available on every model. Please refer to product part number pages for model specifics. Mechanical Information Fixture weight: Standard Models 34W: 4.5 kg (10 lbs) Emergency Models 36W: 5.9 kg (13 lbs) Cable Entry: M20 x 3 Terminals: 4mm 2 x 3 Specifications Voltage options: Housing: Copper-free aluminium Standard Models Finish: 34W: 100-277 VAC Power factor: >0.9 Emergency Models THD: <20% Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy prime 36W: 207-264 VAC Lens: High impact resistant clear glass Operating temp: Standard Models CRI: 70 Frosted glass optional, consult sales 34W: -40 C to +50 C Emergency Models 36W: -20 C to +40 C Emergency Models - Battery CCT: Surge protection: 5650K (cool white) 4300K (neutral white) EN 61000-4-5 1kV line-to-line, 2kV line-toground 36W: 3.6V 10Ah NiMH Expected Battery Life: 4 years Battery Duration: @ 25 C ambient - est. >3 hours *22W & 11W versions available consult sales Comparison Warranty L70 Dialight LED Bulkhead 5yr >100,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 Fluorescent 1 24,000 Standard Models Lumens Wattage lm/w Mounting Heights 2,250 34 66 3m Emergency Models Lumens Wattage lm/w Mounting Heights 2,250 36 62 3m 38 www.dialight.com

Industrial Application Bulkhead DuroSite LED Bulkhead Ordering Information & Mounting Accessories Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Distribution Standard Models - 100-277 VAC WP-4C3L-NLGCE 2,250 34 66 100-277 VAC 5650K (cool white) Tempered Glass Oval (35 x 55 ) Emergency Models - 207-264 VAC WE-4C4L-NLGCE 2,250 36 63 207-264 VAC 5650K (cool white) Tempered Glass Oval (35 x 55 ) All values typical unless otherwise stated (tolerance +/- 10%). WP-BRKT-SS-ADJ Adjustable bracket Includes self-tapping screws WP-BRKT-SS-ADJ 259.4 [10.2] 115.2 [4.5] WPX-001500-BATT 10Ah 3.6V battery module Replacement battery kit Battery Backup models only 37.5 [1.5] 180 [7.1] 75 [3.0] 75 [3.0] 8.5 [.3] 36 [1.4] Also available: WP-BRKT-F-KIT Flush mounting brackets Bracket to fixture hardware Includes (2) brackets in 304 Stainless steel and stainless mounting hardware WP-BRKT-SS-30 30 angle mounting brackets Bracket to fixture hardware Includes (2) brackets in 304 Stainless steel and stainless mounting hardware www.dialight.com 39

Industrial Application Wallpack, Bulkhead DuroSite LED Bulkhead Dimensional Drawings Dimensions Dimension in mm [inches] Beam Distribution Oval Pattern (35 x 55 ) 40 www.dialight.com

Industrial Application Wallpack, Bulkhead DuroSite LED Bulkhead Dimensional Drawings Standard without Bracket 30 Angle Bracket - WP-BRKT-SS-30 Flush Bracket WP-BRKT-F-KIT *Holes are blank and blind Cable Entry - Supplied as Standard 2 Entries One Side, 1 Entry Opposite Side. www.dialight.com 41

Hazardous Application High Bay SafeSite LED High Bay Technical Specification Certifications & Ratings (All Models) IECEx/ATEX Zones 1, 21 IECEx/ATEX Zones 2, 22 CE ABS Design Assessed: (pending) IP66 IK10 Certifications & Ratings (IIB Models) Ex II 2 GD Ex d* IIB T4 Gb Ex tb IIIC 135 C *Add EX e for factory fitted junction box RoHS compliant HEA IECEx BAS 10.0074X BaseefaATEX0148X HEH IECEx BAS 12.0044X Baseefa12ATEX0070X Certifications & Ratings (IIB + Hydrogen Models) Ex II 2 GD Ex d* IIB+H2 T4 Gb Ex tb IIIC 135 C *Add EX e for factory fitted junction box Fixture weight: Mechanical Information 14.1 kg (31 lbs) with fixed cable 15.4 kg (34 lbs) with junction box Wiring options: M25 x 2 Terminals: 4mm 2 x 6 Stainless steel stirrup mounting bracket (included) Temperature Ratings Ambient Temperature Range T4-40 C to +65 C Voltage options: 100-277 VAC 16,000lm & lower models 110-277 VAC 23,000lm models Operating temp: -40 C to +65 C Specifications Housing: Copper-free aluminium Lens: Power factor: >0.9 Finish: THD: <20% Surge protection: Protection devices capable of handling up to 6kV. Tested for 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground CRI: CCT: Tempered glass (optional fragment retention available) Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy prime 75 typical 5000K (cool white) 4000K (neutral white) Comparison Warranty L70 T-Rating Dialight LED High Bay 10yr >150,000 T4 Metal Halide 1 15,000 T2 High Pressure Sodium 1 20,000 T2 Lumens Wattage lm/w Mounting Heights 23,500 212 110 12m 16,000 144 110 12,500 112 110 9,650 88 110 5m Dimensions Dimension in mm 42 www.dialight.com

Hazardous Application High Bay SafeSite LED High Bay Ordering Information & Mounting Accessories Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Distribution Junction Box Models HEA9MC4PN-KCG 23,500 212 110 110-277 VAC 5000K (cool white) Glass Medium HEA9NC4PN-KCG 23,500 212 110 110-277 VAC 5000K (cool white) Glass Narrow HEA9MC4KN-KCG 16,000 144 110 100-277 VAC 5000K (cool white) Glass Medium HEA9NC4KN-KCG 16,000 144 110 100-277 VAC 5000K (cool white) Glass Narrow HEA9MC4GN-KCG 12,500 112 110 100-277 VAC 5000K (cool white) Glass Medium HEA9NC4GN-KCG 12,500 112 110 100-277 VAC 5000K (cool white) Glass Narrow HEA9MC4DN-KCG 9,650 88 110 100-277 VAC 5000K (cool white) Glass Medium HEA9NC4DN-KCG 9,650 88 110 100-277 VAC 5000K (cool white) Glass Narrow All values typical unless otherwise stated (tolerance +/- 10%). Models in chart above are 5000K CCT. For 4000K CCT change the 6th character from C to N & deduct 3% from the lumen table. For optional glass fragment retention film, change the 11th character from a C to a F. Junction box models come standard with M25 entries. For M20 cable entries and leaded versions please consult local Dialight sales office for availability. HBXW3 "Powder-coated aluminium swivel bracket (included with fixture) HBXSBK Sand blast kit (flat lens) HBXSBL Sacrificial flat lens HBXW3-SSL-316M 316 Stainless steel bracket HBXW3-SSL-304M 304 Stainless steel bracket HBXSBDK Sand blast kit (dome lens) HBXSBDL Sacrificial dome lens HBXW3-SSL-304FTM 304 Stainless steel forward throw bracket HBXW3-SSL-316FTM 316 Stainless steel forward throw bracket Beam Distribution Narrow Medium www.dialight.com 43

Hazardous Application Linear SafeSite LED Stainless Steel Linear Technical Specifications Ratings and Certifications 5 year warranty L70 >150,000 hours @ 25 C ambient IECEx / ATEX Zones 1, 21 and Zones 2, 22 IP66/67 IK09 CE Fixture weight: Shipping weight: Cable Entry: Mechanical Information Standard: 1308mm - 11.3 kg (25 lbs) 708mm - 6.8 kg (15 lbs) Emergency: 1308mm - 14.1 kg (31 lbs) 708mm - 9.1 kg (20 lbs) Standard: 1308mm - 14.1 kg (31 lbs) 708mm - 9.1 kg (20 lbs) Emergency: 1308mm - 17.2 kg (38 lbs) 708mm - 10.9 kg (24 lbs) (2) M8 fixing points Terminals 4mm 2 x 7 M25 x 2 cable entries at both ends, through wired as standard. M20 options available, consult sales Voltage options: Operating temp: Power factor: Specifications Standard: 110-250 VAC Housing: 316 Marine grade stainless steel Emergency: 230, 240 VAC Lens: Standard: -20 C to +60 C CRI: 70 Emergency: -20 C to +60 C >0.9 CCT: Surge protection: Emergency Models High impact resistant diffused polycarbonate 5000K (cool white) 4000K (neutral white) Battery: 3.6V 10Ah NiMH Duration: > 180 minutes Expected battery life: 4 years *All features not available on every model. Please refer to product part number pages for model specifics. Emergency battery backup version available.green shower safe models available. EN 61000-4-5 1 kv line to line, 2 kv line to ground Comparison Warranty L70 T-Rating Dialight LED Linear 5yr >150,000 T5 Fluorescent 1 24,000 T4 Standard Model Dimensions Lumens Wattage lm/w Mounting Heights 5,100 64 81 6m 2,600 32 81 3m Emergency Model Dimensions 67 34 Dimension in mm Beam Distribution Medium 44 www.dialight.com

Hazardous Application Linear SafeSite LED Stainless Steel Linear Ordering Information & Mounting Accessories Part Number Fixture Lumens Emergency Mode Lumens Wattage lm/w Voltage Standard Models Colour Temperature (CCT) Lens Beam Distribution ELA-1C6R-SSCB4 5,100 67 76 110-250 VAC 5000K (cool white) Medium ELA-1C6M-SSCB4 2,600 34 76 110-250 VAC 5000K (cool white) Medium ELA-1N6R-SSCB4 4,850 67 72 110-250 VAC 4000K (neutral white) Medium ELA-1N6M-SSCB4 2,500 34 74 110-250 VAC 4000K (neutral white) Medium Shower Safe Models ELA-1G3M-SSC 34 110-250 VAC Green Medium Emergency Models ELEA-2C7R-SSCB4 5,100 271 70 73 230 / 240 VAC 5000K (cool white) Medium ELEA-2C7M-SSCB4 2,600 271 35 74 230 / 240 VAC 5000K (cool white) Medium All values typical unless otherwise stated (tolerance +/- 10%). M20 options available, please consult local Dialight sales office for availability. ELXCMBSS 316 Marine Grade Stainless steel ceiling mount kit ELXEYESS 316 Marine Grade Stainless steel eyelet kit ELX-BATT-KIT Emergency model 3.6V 10Ah NiMH battery kit ELXPCSS42 40-45mm range 316 Marine Grade Stainless steel pole clamp ELXPCSS47 47-51mm range 316 Marine Grade Stainless steel pole clamp ELXPCSS54 54-57mm range 316 Marine Grade Stainless steel pole clamp ELXPCSS59 59-62mm range 316 Marine Grade Stainless steel pole clamp ELXWMBSS30 30 316 Marine Grade Stainless steel wall mount kit ELXWMBSS45 45 316 Marine Grade Stainless steel wall mount kit ELXWMBSS60 60 316 Marine Grade Stainless steel wall mount kit ELXWMBSS90 90 316 Marine Grade Stainless steel wall mount kit Mounting Options Wall Mount Bracket 30 Wall Mount Bracket 45 Wall Mount Bracket 60 Wall Mount Bracket 90 Pole Clamp Ceiling Mount Eyelet www.dialight.com 45

Hazardous Application Area Light SafeSite LED Area Light Technical Specifications Ratings and Certifications 5 year warranty L70 >150,000 hours @ 25 C ambient IECEx/ATEX Zones 1, 21 IECEx/ATEX Zones 2, 22 IP66 IK08 CE *All features not available on every model. Please refer to product part number pages for model specifics. Mechanical Information Fixture weight: 9.1 kg (20 lbs) Shipping weight: 10.0 kg (22 lbs) 316 Stainless steel mounting bracket Cable Entries: M20 x 2 Specifications Voltage: 100-277 VAC Housing: Copper-free aluminium Operating temp: -40 C to +65 C Finish: Power factor: >0.9 THD: <20% Lens: Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy prime Tempered Glass Terminals: 4mm 2 x 5 Surge protection: 1kV line-to-line, 2kV line-to-ground CRI: 75 5000K (cool white) CCT: 4000K (neutral white) Comparison Warranty L70 T-Rating Dialight LED Area Light 5yr >150,000 T5 Metal Halide 1 15,000 T3 High Pressure Sodium 1 20,000 T2 Lumens Wattage lm/w Mounting Heights 7,500 69 109 6m 6,500 58 112 5,500 47 117 3m -- 213 [8.4] 94 [3.7J Dimensions 2x M20xl. ----2 7 2 [10.7 J 202 l [8.0] 7 7 [3.0 J 3 0 I [11.8J 246 [9.7] ----2 7 2 Dimension in mm [inches] 46 www.dialight.com

Hazardous Application Area Light SafeSite LED Area Light Ordering Information Part Number Lumen Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Distribution HZJA9C2N 6,000 58 103 100-277 VAC 5000K (cool white) Tempered glass 360 HZJA8C2N 5,600 58 97 100-277 VAC 5000K (cool white) Tempered glass 180 HZJA5C2N 5,100 47 109 100-277 VAC 5000K (cool white) Tempered glass 360 HZJA4C2N 4,600 47 98 100-277 VAC 5000K (cool white) Tempered glass 180 HZJA3C2N 4,000 38 105 100-277 VAC 5000K (cool white) Tempered glass 360 HZJA2C2N 3,600 38 95 100-277 VAC 5000K (cool white) Tempered glass 180 HZJA1C2N 2,200 22 100 100-277 VAC 5000K (cool white) Tempered glass 360 HZJA0C2N 2,200 22 100 100-277 VAC 5000K (cool white) Tempered glass 180 All values typical unless otherwise stated (tolerance +/- 10%). Leaded options available, please consult local Dialight sales office for availability. Beam Distribution 180 360 www.dialight.com 47

Hazardous Application Bulkhead SafeSite LED Bulkhead Technical Specifications Ratings and Certifications 5 year warranty ATEX/IECEx Zones 1, 21 IP66/67 ATEX/IECEx Zones 2, 22 IK09 Emergency models available ABS CE L70 >100,000 hours @ 25 C ambient *All features not available on every model. Please refer to product part number pages for model specifics. Mechanical Information Fixture weight: Standard Models 22W: 4.8 kg (10.5 lbs) 34W: 5.2 kg (11.5 lbs) Specifications Voltage options: Housing: Copper-free aluminium Finish: Standard Models Power factor: >0.9 Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy prime Emergency Models 24W: 6.1 kg (13.5 lbs) 22W / 34W: 100-277 VAC THD: <20% Lens: High impact resistant clear glass 36W: 6.6 kg (14.5 lbs) Supplied without brackets Cable Entry: M20 x 3 Emergency Models (Frosted glass optional, consult sales) 24W: 207-264 VAC CRI: 70 36W: 207-264 VAC 5650K (cool white) CCT: Operating temp: 4300K (neutral white) Terminals: 4mm 2 x 3 Standard Models Emergency Models 22W: -40 C to +60 C Battery 34W: -40 C to +50 C Emergency Models 24W / 36W: 3.6V 10Ah NiMH 24W: -20 C to +50 C Expected Battery Life: 4 years 36W: -20 C to +40 C Battery Duration: @ 25 C ambient - est. >3 hours Surge protection: EN 61000-4-5 1 kv line to line, 2 kv line to ground Comparison Warranty L70 Dialight LED Bulkhead 5yr >100,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 Fluorescent 1 24,000 Standard Models Lumens Wattage lm/w Mounting Heights 2,250 34 66 3m 1,200 22 55 Emergency Models Lumens Wattage lm/w Mounting Heights 2,250 36 62 3m 1,200 24 50 48 www.dialight.com

Hazardous Application Bulkhead SafeSite LED Bulkhead Dimensional Drawings Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Standard Model - 100-277 VAC Lens Beam Distribution WPA-4C3L-NLGCE 2,250 34 66 100-277 VAC 5650K (cool white) Clear tempered glass Oval (35 x 55 ) Emergency Models - 207-264 VAC WEA-4C4L-NLGCE 2,250 36 63 207-264 VAC 5650K (cool white) Clear tempered glass Oval (35 x 55 ) All values typical unless otherwise stated (tolerance +/- 10%). WP-BRKT-SS-ADJ Adjustable bracket Includes self-tapping screws WP-BRKT-SS-ADJ 259.4 [10.2] 115.2 [4.5] WPX-001500-BATT 10Ah 3.6V battery module Replacement battery kit Battery Backup models only 37.5 [1.5] 180 [7.1] 75 [3.0] 75 [3.0] 8.5 [.3] 36 [1.4] Also available: WP-BRKT-F-KIT Flush mounting brackets Bracket to fixture hardware Includes (2) brackets in 304 Stainless steel and stainless mounting hardware WP-BRKT-SS-30 30 angle mounting brackets Bracket to fixture hardware Includes (2) brackets in 304 Stainless steel and stainless mounting hardware www.dialight.com 49

Hazardous Application Bulkhead SafeSite LED Bulkhead Dimensional Drawings Dimensions - Standard Dimension in mm [inches] Beam Distribution Oval (35 x 55 ) 50 www.dialight.com

Hazardous Application Bulkhead SafeSite LED Bulkhead Dimensional Drawings Standard without Bracket 30 Angle Bracket - WP-BRKT-SS-30 Flush Bracket WP-BRKT-F-KIT *Holes are blank and blind Cable Entry - Supplied as Standard 2 Entries One Side, 1 Entry Opposite Side. www.dialight.com 51

Hazardous Application Transportable SafeSite LED Transportable High Bay Technical Specifications Certifications & Ratings (All Models) IECEx / ATEX Zones 1, 21 IECEx / ATEX Zones 2, 22 CE ABS Design Assessed: (pending) IP66 IK10 Certifications & Ratings (IIB Models) Ex II 2 GD Ex d* IIB T4 Gb Ex tb IIIC 135 C *Add EX e for factory fitted junction box Certifications & Ratings (IIB + H2 Models) Ex II 2 GD Ex d* IIB+H2 T4 Gb Ex tb IIIC 135 C *Add EX e for factory fitted junction box RoHS compliant HEA IECEx BAS 10.0074X BaseefaATEX0148X HEH IECEx BAS 12.0044X Baseefa12ATEX0070X Mechanical Information Specifications Fixture weight: Fixing: 19.5 kg (43 lbs) Factory installed 10m cable, no plugs SWB (steel wire braided) cable Voltage: 100-277 VAC Housing: Finish: Copper-free aluminium Superior dual coat finish color - RAL Yellow Operating temp: -40 C to +60 C Lens: Tempered glass Power factor: >0.9 CRI: 80 THD: <20% CCT: 5000K (cool white) Surge protection: Protection devices capable of handling up to 10kV. Tested for 10kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground Dimensions Dimension in mm [inches] Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Distribution THA9MC4KN-BCG 16,000 144 110 100-277 VAC 5000K (cool white) Tempered glass Medium All values typical unless otherwise stated (tolerance +/- 10%). 52 www.dialight.com

Hazardous Application Transportable SafeSite LED Transportable Bulkhead Technical Specifications 5yr warranty L70 >100,000 hours IP66 ATEX Zones 1, 21 ATEX Zones 2, 22 IK08 CE Ratings and Certifications *All features not available on every model. Please refer to product part number pages for model specifics. Fixture weight: Fixing: Mechanical Information 11 & 22W - 5.75 kg (10.5 lbs) 34W - 5.9 kg (10.8 lbs) Factory installed 10m cable, no plugs Voltage options: 34W-100-277 VAC Specifications Housing: Finish: Operating temp: 34W- -40 C to +50 C Lens: Power factor: >0.9 CRI: 70 Copper-free aluminium Superior dual coat finish color - RAL Yellow High impact resistant glass THD: <20% CCT: 5000K (cool white) Surge protection: 1 kv line to line, 2 kv line to ground Dimensions Dimension in mm [inches] Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Beam Distribution TWA-2C3L-SYWC 2,250 34 66 100-277 VAC 5000K (cool white) Clear glass Narrow All values typical unless otherwise stated (tolerance +/- 10%). When ordering, please refer to www.dialight.com and the current data sheets to ensure proper and most up-to-date information. www.dialight.com 53

Infrastructure Solutions Street Light StreetSense LED ATEX/IECEx Street Light Technical Specifications 7 year warranty CE IECEx/ATEX Zone 2 IK07 Ratings and Certifications *All features not available on every model. Please refer to product part number pages for model specifics. Mechanical Information Specifications Fixture weight: 1 light engines: 7.3 kg (16 lbs) 2 light engines: 1.3 kg (25 lbs) 3 light engines: 15.4 kg (34 lbs) Voltage: 100-277 VAC, 50/60 Hz Housing: Aluminium alloy A360 Operating temp: -40 C to +74 C Lens: Tempered glass Shipping weight: 1 light engines: 9.5 kg (21 lbs) 2 light engines: 13.6 kg (30 lbs) 3 light engines: 17.7 kg (39 lbs) Accommodates 31.75mm (42.16mm OD) - 50.8mm (60.32mm OD) pipe. Provision for adjustment of +/- 5 at 2.5 increments Power factor: >0.9 CRI: 70 THD: <20% CCT: Surge protection: 5000K (cool white) 4300K (neutral white) Open circuit surge protection 6kV standard per ANSI/IEEE C62.41. 2.2002 cat C low or Open circuit surge protection 10kV standard per ANSI/IEEE C62.41. 2.2002 cat C high Cable Entries: M25 x 1 rear Terminals: 3.3mm 2 x 3 Comparison Warranty L70 Lumens Wattage lm/w Mounting Heights 20,250 252 80 17m Dialight LED Street Light 7yr >100,000 Metal Halide 1 15,000 High Pressure Sodium 1 20,000 16,000 190 84 10,900 131 83 6,800 83 82 5,500 65 85 5m Dimensions 122 [4.8] 880 [34.7] 674 [26.5] 467 [18.4] 372 [14.7] Dimension in mm [inches] 54 www.dialight.com

StreetSense LED ATEX/IECEx Street Light Ordering Information Infrastructure Solutions Street Light Part Number Lumens Wattage lm/w Voltage Colour Temperature (CCT) Lens Light Engines ATEX / IECEx Zone 2 SLA3N4SG 20,250 252 80 100-277 VAC 4300K (neutral white) Glass 3 SLA3C4SG 20,250 252 80 100-277 VAC 5000K (cool white) Glass 3 SLA3N4HG 10,900 131 83 100-277 VAC 4300K (neutral white) Glass 2 SLA3C4HG 10,900 131 83 100-277 VAC 5000K (cool white) Glass 2 SLA3N4CG 5,500 65 85 100-277 VAC 4300K (neutral white) Glass 1 SLA3C4CG 5,500 65 85 100-277 VAC 5000K (cool white) Glass 1 All values typical unless otherwise stated (tolerance +/- 10%). Beam Distribution Type III www.dialight.com 55

Obstruction Signals Obstruction LED Lighting ICAO Red LED Systems: Medium Intensity ICAO Type B/Type C Features & Benefits Integrated controller 5 year warranty Universal 120-240 VAC input Controller can be mounted at the base of the structure Wide temperature range: -40 o C to +55 o C Configurable flash rates (20, 30, or 40 flashes per min) Ability to operate lights in steady or flashing mode Optional infrared light fixtures Light weight design Low power consumption IP66 rated light fixtures Impact and vibration resistant Provision for padlock on the enclosure Dry contacts for alarm monitoring/status Photocell alarm Light alarms Operation mode (day/night) Largest Controller can control and monitor maximums of: Twelve (12) Medium Intensity ICAO Type B/Type C and Twenty Four (24) Low Intensity ICAO Type B/ Type E Dual (Red/White) LED Systems: Medium Intensity ICAO Type A/Type B Features & Benefits Infrared (IR) version available for improved visibility to Night Vision Goggles Optional Ethernet/Cellular based remote monitoring/ control system available Ability to flash side markers Integrated controller with LCD back-lit display 5 year warranty Universal 120-240 VAC input or +/- 48 VDC input Controller can be mounted at the base of the structure Wide temperature range: -40 o C to +55 o C Light weight design Low power consumption IP66 rated light fixtures Impact and vibration resistant Provisions for padlock on the enclosure Dry contacts for alarm monitoring/status Photocell alarm White mode alarm Power fail Light alarms Red mode alarm Communication Operation mode (day/night) Sync alarm White LED Systems: Medium Intensity ICAO Type A Features & Benefits Integrated controller with LCD back-lit display Optional Ethernet/Cellular based remote monitoring/ control system available 5 year warranty Universal 120-240 VAC input or 48 VDC input Controller can be mounted at the base of the structure Wide temperature range: -40 o C to +55 o C Light weight design Low power consumption IP66 rated light fixtures Impact and vibration resistant Provisions for padlock on the enclosure Dry contacts for alarm monitoring/status Photocell alarm White mode alarm Power fail Light alarms Communication Operation mode (day/night) Sync alarm High Intensity LED Systems: ICAO Type A Features & Benefits Integrated controller 5 year warranty Universal 208-277 VAC input Controller can be mounted at the base of the structure Wide temperature range: -40 o C to +55 o C Low power consumption IP66 rated light fixtures Impact and vibration resistant Provision for padlock on the enclosure Dry contacts for alarm monitoring/status Photocell alarm White mode alarm Power fail Red mode alarm Communication Operation mode (day/night) Sync alarm When ordering please refer our website www.dialight.com to view the current versions of all relevant product documentation, including the most up to date product data sheets. For the avoidance of doubt, in the event of any discrepancy between the contents of this document and information provided on our website, the information provided on our website shall prevail. 56 www.dialight.com

Obstruction Signals Obstruction LED Lighting ICAO Vigilant LED Based ICAO Type A High Intensity (White / Red) Strobe Effective Intensity: Wattage: Input Voltage: White Day 200,000 cd White Twilight- 20,000 cd White or Red Night- 2,000 cd White day - 160W White twilight - 30W White Night - 23W Red Night - 30W 208-277 VAC Vigilant LED Based ICAO Type A/Type B Medium Intensity (White/Red) Strobe - Infrared (IR) available Effective Intensity: White Day- 20,000 cd White Night- 2,000 cd Red Night- 2,000 cd Wattage: White Day- 36W (system = 75W) White Night- 4W (system = 10W) Red Night- 12W (system = 25W) Input Voltage: 120-240 VAC or +/- 48 VDC Vigilant LED Based ICAO Type B/Type C Medium Intensity (Red) Beacon - Infrared (IR) available Effective Intensity: 2,000 cd Wattage: Input Voltage: 3.3W (16.7% duty circle) - standard 7.0W (16.7% duty circle) - IR model 20 flashes per minute with 0.5 sec. on time 120-240 VAC or 24-48 VDC Vigilant LED Based ICAO Type B/Type E Low Intensity (Red) RTO Side Light - Infrared (IR) available Effective Intensity: 32.5 cd Wattage Range: Input Voltage: 1.5-9.0W 12-48 VDC, 120-240 VAC, 277 VAC Vigilant LED Based ICAO Type B/Type E Low Intensity (Red) Side Light Effective Intensity: 32.5 cd Wattage Range: 13-24W Input Voltage: 12-48 VDC, 120 VAC, 230 VAC When ordering please refer our website www.dialight.com to view the current versions of all relevant product documentation, including the most up to date product data sheets. For the avoidance of doubt, in the event of any discrepancy between the contents of this document and information provided on our website, the information provided on our website shall prevail. www.dialight.com 57

EMEA Catalogue Notes When ordering please refer our website www.dialight.com to view the current versions of all relevant product documentation, including the most up to date product data sheets. For the avoidance of doubt, in the event of any discrepancy between the contents of this document and information provided on our website, the information provided on our website shall prevail. 58 www.dialight.com

EMEA Catalogue Notes When ordering please refer our website www.dialight.com to view the current versions of all relevant product documentation, including the most up to date product data sheets. For the avoidance of doubt, in the event of any discrepancy between the contents of this document and information provided on our website, the information provided on our website shall prevail. www.dialight.com 59

EMEA Technical Centre Ejby Industrivej 91 B 200 Glostrup Tel: +45 8877 4545 (Denmark) Tel: +44 1638 666541 (UK) Tel: +49 89 12089 5713 (Germany) Tel: +33 3 23 22 62 58 (France) sales-europe@dialight.com Australia 38 O'Malley Street Osborne Park, WA 6017 Tel: +61 (0) 8 9244 7600 Fax: +61 (0) 8 9244 7601 info@dialight.com.au Brazil Alameda Mercurio 225 American Park Empresarial NR Indaiatuba SP 13347 662 Tel: +55 (19) 3113-4300 Fax: +55 (19) 3113-4300 brasil@dialight.com Houston 16830 Barker Springs Rd Ste 407, Houston, TX 77084 Tel: 732-919-3119 Fax: 281-492-1531 info@dialight.com Middle East Level 42 Emirates Towers (Office Tower) Sheikh Zayed Road Dubai, United Arab Emirates Tel: +971 (0) 4319 7686 Fax:+971 (0) 4319 7686 North American HQ 1501 Route 34 South Farmingdale, NJ 07727 Tel: 732-919-3119 Fax: 732-751-5778 info@dialight.com Southeast Asia 33 Ubi Avenue 3 #07-72 Vertex (Tower A) Singapore 408868 Tel: +65 6578 7157 Fax: +65 6578 7150 enquiry@dialight.com.sg All values and performance data contained herein are design or typical values when measured under laboratory conditions. Dialight products are intended for ultimate purchase by industrial users and for operation by persons trained and experienced in the use and maintenance of this equipment. While every precaution has been taken to ensure accuracy and completeness of the information in this document, this document does not form part of any contract with Dialight and Dialight does not assume any liability for damages resulting from the use of this information, including any information on third party websites linked to from this document. The information in this document is subject to change without notice. The products or software referenced in this document are subject to the applicable warranties and terms and conditions of use/purchase. Unless agreed otherwise in writing, Dialight does not warrant or represent that its products are fit for a particular purpose and accepts no responsibility for the installation or unauthorised use of its products. Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at: www.dialight.com MDTFSHCATEUX001_H_March2018