Tradition Plus Clad-Wood Awning Windows Premium Wood

Similar documents
Awning Windows Premium Atlantic Vinyl

PREMIUM VINYL. Awning Casement Single-Hung Double-Hung Sliding Fixed, Radius & Geometric Bay & Bow Sliding Patio Doors

WINDOWS CRUSADER ENTRY DOORS

Visions 3000 Series 9404 Parts Catalog

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

Introduction...COMB-2 Design Considerations and Examples...COMB-3

SECTION SPECIFICATIONS PART 1 GENERAL

Arcade Windows. Architectural Design Manual. July 2014

59 1/16" (1500 mm) & 63" (160 mm) Combinations. 70 7/8" (1800 mm) Combinations. Awning Window/Wall Connection

WINDOW COLLECTIONS.

Truly Superior Series. New Construction Vinyl Windows & Patio Doors. Windows. Warren Diggles Photography

Frameless All Glass Wall Systems (no stiles but with rails)

Series 2050 Garden Window Frequently Asked Questions

1Perma-Shield Gliding Doors (PSI 1968 to 1978)

Major Features of VWD Windows

1Perma-Shield Gliding Doors (PSI 1968 to 1978)

Whatever you can dream, Andersen can help you build.

JOINING MULLION (DIRECT MULL) ASSEMBLY INSTRUCTIONS FOR 3-WAY OR 4-WAY JOINTS FOR IMPERVIA AWNING, CASEMENT AND LARGE AWNING

HARDWARE Selection Guide 01

DOOR - Single Leaf, Premium Duty, Quick-Acting Model 1430 Features 1

apexfacades.com apexfacades.com Printed on 12/12/17

FIXED WINDOW SECTION DETAILS

Vinyl French Door Assembly Instructions

Closet and Specialty Hardware

Storm Windows. Tru-Channel. Comparative Air Infiltration Rates (CFM/FCP) The lower the number, the better the performance.

SECTION 5. Hardware and Optional Accessories for Steel Doors:

SCREENS TABBED PAGE SCREENS

ADJUSTABLE. SUPPORT ANDO bi-fold operator can be supplied non-key locking. The furniture is available in a range of standard or special colours.

storm windows Tru-Channel

Closet and Specialty Hardware

CLASSIC VINYL BEAUTY WINDOWS EFFICIENCY SECURITY COMFORT

PREMIUM Vinyl Multi-Purpose Windows and Doors

4 Season Enclosure. 3 Season Enclosure. Screen Enclosure. Suggested Installation Instructions. Patio Cover / Car Shield

MINNKOTA WINDOWS SERVICE REPLACEMENT PARTS

AMS MU800 Mullion Drained Curtain Walling

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

WINDOW TECHNOLOGY ORDER CATALOG SECTION Casement & Awning Windows Hardware

Why Majestic Signature Series Windows?

A201 DOUBLE HUNG Sill WHITE - UI0028S1 ALMOND - UI0028S4 CLAY - UI0028S5 BRZ/WHT - UI HEAD/JAMB

Storm Doors. Ultimate quality with functional beauty, storm-screen doors are perfect for all season performance. CUSTOMBUILTRI.COM

COMP 6 Frame Parts. Comp (U1 REVISED) 6.1

Features. 1 High performance Low-E glass maximizes energy efficiency. 1

Frame and Mullion Lite Pattern Options. Style 10 LP001-6 Lites 2 wide x 3 high. Style 1996 LP101 over 2wx2h Lites. Style 996L

Storm Door Collection

Hotels Office Space Baths Barn Doors Restaurants Galleries Lofts Kitchens Rustic Homes Closets Recessed Storage

MetroView TM FG 501T Window Wall

Enjoy unlimited benefits with Imperial LS Windows.

SEEK QUALITY Seek Quality

WELCOME TO THE EXQUISITE EXPERIENCE THAT IS COASTAL SHOWER DOORS 2

7700 WINDOWS WIN77008PG 2699.NH.5K.0918

Custom and Pre-Configured Restaurant Doors

PREFERRED WINDOWS & DOORS BUILDING & REMODELING

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

SECURITY HARDWARE. Security Hardware

Stainless Steel Catheter Storage Cabinets

Muskoka Folding Glass Wall System

Structural Mullion System

PRO VINYL WINDOWS ELEGANCE STRENGTH EFFICIENCY PROTECTION

2019 STORM DOORS STORM DOORS

Lockable Fasport. IFP-600 Dimensions Overall Height 9.5" Overall Width 10" Opening Dia. 6.5" Weight 9 lbs. Model

LIFESTYLE CLASSIC COLONIAL WINDOW SYSTEMS

DURABLE LIGHTWEIGHT TABLES ABS RECTANGLE

250 SERIES 1" STRUCTURAL TUBE MULLION ASSEMBLY INSTRUCTIONS

WINDOW & DOOR COLLECTIONS PROUDLY SERVING ATLANTIC CANADIANS FOR OVER 40 YEARS.

Table Of Contents RV WEATHERSTRIPPING

GV Standard Skyhatch Manual

SHOPFITTING. Grooved panel 664. Grooved panel accessories 665. Cash drawers 668. Partition hardware 675. Toilet partitions 686

COMMERCIAL GRILLE DOORS

EXTERIOR SOLAR SCREENS

WARDROBE FITTINGS Wardrobe Accessories P Clothes Hanger Accessories P Hangers & Shoe Racks P.

The tried-and-tested complete range

Single & double hung hardware

CLASSIC ALUMINUM STORM DOORS gerkin.com

Louvre Specifications

BAINBRIDGE LUXURY EDITION BEAUTY EFFICIENCY SECURITY DURABILITY

. crealco C A S E M E N T Index Legal Disclaimer 5 Profile Identification 6-8 Hardware Identification 9 New Crimper 10 Butterfly Gasket and Wed

YCU 750 TU Unitized Curtain Wall System

Operators & hinges for windows/skylights

Closet and Specialty Hardware

Model STEEL-VISION Perforated Curved or Flat Slats Rolling Service Door

porch & patio enclosures

Wv410 window. Installation Instructions

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

Extending Your Space... Is Our Business! designing, producing, building...your glass world!

Your new home is the promise. Let Our idea series Windows Bring Your New Home to Life

Hardware Resources

AWNING WINDOW SYSTEMS ENCORE AWNING NOW AVAILABLE WITH KEY LOCKING SNAP FIT INSTALLATION ZINC DIECAST COVER AND HANDLE INTERCHANGEABLE CYLINDERS

C11.15 HANDLES AND LOCKCASES C11 SIDE HUNG WINDOWS

CASEMENT WINDOW SYSTEMS ENCORE DUAL ARM NOW AVAILABLE WITH KEY LOCKING SNAP FIT INSTALLATION ZINC DIECAST COVER AND HANDLE INTERCHANGEABLE CYLINDERS

A11.15 HANDLES AND LOCKCASES A11 TURN-TILT WINDOWS

Section 11 Workstation Components

4 1 2" System Depth Dry Glazing Compatible with a variety of Windspec doors and operable windows Available in anodized and painted finishes

High energy efficiency

SECTION TOILET ACCESSORIES

O u r Wa r r a n t y. For more information on Ideal s warranty please visit our website at

2016 PRODUCTS & PRICES

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:

KAWNEER 1786 RIM EXIT DEVICE

Specification sheets for Panel Systems, Shower Pans, Shower Enclosures, and Accessories

Enjoy unlimited benefits with Imperial LS Windows.

Transcription:

TABLE OF CONTENT pecifications... 3-2 QuickpecGuide... 3-3 Elevations:1/4 cale... 3-4 ingleunits... 3-6 GlazingOptions:3 cale... 3-9 TrimOptions:3 cale... 3-10 JambExtenderOptions:3 cale... 3-11 tandard Mullion Options... 3-12 LiteCutInformation&Options... 3-13 BasicUnitpecification... 3-15 VentProjections... 3-17 Unit izing, Rough Openings & Masonry Openings... 3-18 ectiondetails:6 cale... 3-19 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-1

PRODUCT PECIFICATION EXTERIOR FINIH Exterior aluminum surfaces are low maintenance extruded aluminum frame and roll-formed aluminum sash coated with a thermo set polyester finish that meets or exceeds the AAMA 2603 performance standards. tandard colors include Brilliant White, Chestnut Bronze, Desert and, French Vanilla, Hartford Green, and Mesa Red. AURALAT WOOD AuraLastt wood is fundamentally different from wood resulting from traditional millwork preservation processes in that it uses a proprietary vacuum/pressure process to provide protection throughout the wood parts used to make windows and doors. AuraLastt wood is distinguished from wood using the current preservation methods by its unique ability to achieve greater penetration of the active ingredients into the wood parts, with a penetration of the treatment being a minimum of 92%. INTERIOR FINIH All interior surfaces are unfinished clear pine ready for paint, stain or natural finish. Primed and pre-painted white interiors are available. FRAME Frame is 1-3/32 assembled from select kiln dried pine using AuraLastt wood on all exterior parts. Exterior surface is covered with.055 extruded aluminum extrusion. The basic jamb width is 2-9/16 with clear pine interior. Jamb extensions are available for most wall thicknesses. Reinforced nylon corner locks are injected with sealant to seal the jamb frame corners. Integral nailing fin is part of extrusion on all four sides. Assembled frame includes all weather-stripping and hardware installed. The assembled frame includes a drip cap. Exterior of frame extrusion is grooved to accept accessories. AH The sash is 1-15/32 constructed of 6/4 select kiln-dried pine using AuraLastt wood. Wood stiles and rails are joined with mortise and tenon corners and secured with metal fasteners. Exterior surfaces are covered with.019 roll formed aluminum cladding overlapped at the sash corners to shed water. GLAZING 3/4 (19mm) thick sealed insulating glass is constructed from two panes of glass, utilizing a continuous roll formed stainless steel spacer with dual seal sealant. The glass is mounted into the sash using a silicone-glazing compound and secured with interior applied profiled wood stops. All insulating glass units comply with the performance requirements of IGCC in accordance with either ATM E774 or E2190. GLAZING OPTION 3/4 insulating glass available in Low-E with Argon, Low-E 366, Clear, Neat Glass, tinted, or obscure, tempered or other specialty glass as specified. Optional Preserve film is a 0.003 thick polyethylene film with a low tack acrylic adhesive applied to the glass for protection during shipping and installation. WEATHER-TRIPPING A rigid vinyl leaf weather-stripping is applied to the sash and full perimeter. TPE bulb weather-stripping is used on the frame. HARDWARE ash are hinged on corner pivoting concealed type hinges with sliding steel reinforced nylon shoes in stainless steel tracks. The double-coated split arm hinge design allows the sash to slide toward the center of the frame for ease of cleaning of the the exterior pane of glass. The single arm roto-operator has a zinc die cast base, cover and nylon roller. INTERIOR INECT CREEN Charcoal fiberglass screen cloth (18x16 mesh) set in an aluminum frame (.019ga) with nylon corner keys. creens are mounted with leaf springs. Insect screens are intended to allow air and light in and to keep insects out. They are not intended to keep anyone or anything from falling through an open window. For safety screens or other security devices contact your local building supply retailer. GRILLE DL (imulated Divided Lites) - extruded aluminum muntins permanently applied to the exterior of the insulating glass unit (not available on textured glass) in 7/8 (22mm), 1-1/8 (28.5mm), or 1-3/8 (34.9mm) widths. DL may be ordered with a silver shadow bar or without a shadow bar. Clear wood interior muntin bars match the exterior muntin width and are permanently bonded to the interior of the glass. Also available is a 2-1/8 DL bar, which simulates a double-hung checkrail. Full urround Wood Grilles - Rectangular pattern, unfinished clear pine wood grilles in 7/8 (22mm), 1-1/8 (28.5mm), and 1-3/8 (34.9mm) are available in patterns selected by the owner. GBG (Grilles between the Glass) - 5/8 (15.9mm) flat and 23/32 or 1 contour mounted between the glass panes suspended within the air cavity. EXTERIOR TRIM 1-11/16 wide brickmould, 3-7/32 wide flat casing and 3-7/32 wide Adams casing. All aluminum casings have a 1-9/16 thick extruded aluminum sill nosing. tandard 1/2 clad mull cover for mulling units together and 3/4, 1-1/2, 2 and 4 optional mull covers for expanded mulls. EXTENION JAMB Extension jambs using select kiln-dried pine are factory applied to the interior on all four sides of the frame in wall depths up to 10-9/16. Extension jambs up to depths of 7-1/4 use one piece, and up to 10-9/16 (217mm) use two pieces. INTALLATION Installation per JELD-WEN Installation Method for Metal Clad Windows JII002 or JII013. ee www.jeld-wen.com/resources for instructions. PERFORMANCE NFRC Certified - (Rated and labeled in accordance with NFRC) July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-2

QUICK PEC GUIDE PECIFICATION EXTERIOR FINIH Brilliant White Chestnut Bronze Desert and French Vanilla TANDARD FEATURE Mesa Red Hartford Green Black OPTIONAL FEATURE ome options may require additional lead times. Consult your JELD-WEN ales Representative. INTERIOR FINIH Natural Primed or Painted White Finish IZE Width: 20, 24, 28, 30, 36, 40, 48, 56, 60 Height: 17, 20, 24, 30, 36, 40, 48 GLAZING Low-E Insulating Glass Preserve Protective Film AnyWidth:17to60in1/8 increments Any Height: 17 to 48 in 1/8 increments Clear Obscure Low-E 366 Neat Glass High Altitude HARDWARE Folding Handle T-Handle Round Knob ADA Compliant Handle HARDWARE COLOR Chestnut Bronze Bright Brass White Antique Brass Desert and Brushed Chrome Imitation Oil Rub Bronze CREEN Fiberglass Aluminum Mesh CREEN FRAME COLOR Color Match Clad Tints: Bronze, Gray, Green Reflective Tints: Bronze, Gray Tempered GRILLE 7/8, 1-1/8 and 1-3/8 Removable Interior Grilles 7/8, 1-1/8 and 1-3/8 Removable Full urround 7/8 Removable Interior Vinyl Grille 5/8 Flat; 23/32 and 1 Profiled GBG 7/8, 1-1/8, 1-3/8 and 2-1/8 DL options: 7/8, 1-1/8, 1-3/8 DL with Removable Interior Full urround Wood Grille 7/8, 1-1/8, 1-3/8 DL with Permanently Applied Interior Wood Grille 7/8, 1-1/8, 1-3/8 DL with Permanently Applied Interior Wood Grille & ilver hadow Bar 2-1/8 imulated Checkrail EXTERIOR TRIM Integral Nailing Fin Aluminum Brickmould Aluminum Adams or Flat Casing - 3-7/32 wide JAMB Applied 4-9/16 Minimum: 2-1/2 Maximum: 7-1/4 one piece Maximum: 10-9/16 two piece July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-3

GENERAL INFORMATION DIMENIONAL WINDOW Clad awning windows may be specified as dimensional by adjusting the desired rough opening width or height in 1/4 increments from standard. Clad awning windows are available as operating or stationary (non - venting). Operating mechanism includes corrosion resistant steel hinges and roto-type operators for venting units. ash locks are concealed unison type with an exposed locking lever and escutcheon plate. There are several interior hardware finish options. Refer to the pecifications for finish options. MULTIPLE AEMBLIE Clad awning windows may be mulled above, below, or beside other clad awning windows, or other clad window products. Factory assembled mulls are limited in height (100 ), width (150 ), and a total area (75 square feet). CALE: 1/4 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-4

ELEVATION NOTE ELEVATION DRAWING UTILIZE A LIMITED NUMBER OF PROJECTED LINE TO PRODUCE A RUDIMENTARY DRAWING INTENDED TO BE UED IN A MALL GRAPHICAL CALE. ELEVATION ARE VIEWED PERPENDICULAR FROM THE EXTERIOR OF THE TRUCTURE. IF MORE DIMENION ARE NEEDED, UE THE ECTION DRAWING FOR MORE COMPLETE DEPICTION. M.O. Brickmould M.O. Adams/Flat Casing Rough Opening Frame ize Glass ize 20 29/64 (520) 21 63/64 (558) 17 3/4 (451) 17 (432) 10 15/16 (276) 27 3/4 (705) 30 13/16 (783) 24 3/4 (629) 24 (610) 17 15/16 (455) Masonry Openings for Brickmould, Flat & Adams Casing. Vertical measurements include subsill. (ubtract 1/2 from Masonry Opening for Unit ize) DP RATING EE YMBOL LEGEND BELOW OPTIONAL DP RATING EE YMBOL LEGEND BELOW OUTIDE OF FRAME TCA INDICATE TRADITION PLU CLAD AWNING TCA2417 BOOK CODE THE FIRT TWO NUMBER INDICATE THE UNIT WIDTH THE LAT TWO NUMBER INDICATE THE UNIT HEIGHT GENERAL AWNING NOTE 1. TRADITION PLU CLAD AWNING (TCA) UNIT ARE AVAILABLE A OPERATING OR TATIONARY UNIT. 2. UNIT ELEVATION ARE HOWN WITHOUT EXTERIOR TRIM. ELEVATION YMBOL LEGEND: M.O. MAONRY OPENING 3. DIMENIONAL VALUE IN PARENTHEE ARE MILLIMETER CONVERION. CALE: 1/4 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-5

INGLE UNIT M.O. BRICKMOULD M.O. ADAM/FLAT CAING ROUGH OPENING FRAME IZE DAYLIGHT OPENING 20 3/4 (527) 23 13/16 (605) 17 3/4 (451) 17 (432) 10 15/16 (276) 23 3/4 (603) 26 13/16 (681) 20 3/4 (527) 20 (508) 13 15/16 (354) 27 3/4 (705) 30 13/16 (783) 24 3/4 (629) 24 (610) 17 15/16 (455) 31 3/4 (806) 34 13/16 (884) 28 3/4 (730) 28 (711) 21 15/16 (557) 33 3/4 (857) 36 13/16 (935) 30 3/4 (781) 30 (762) 23 15/16 (608) 35 3/4 (908) 38 13/16 (986) 32 3/4 (832) 32 (813) 25 15/16 (659) 39 3/4 (1010) 42 13/16 (1087) 36 3/4 (933) 36 (914) 29 15/16 (760) 20 29/64 (520) 21 63/64 (558) 17 3/4 (451) 17 (432) 10 15/16 (276) TCA1717 TCA2017 TCA2417 TCA2817 TCA3017 TCA3217 TCA3617 23 29/64 (596) 24 63/64 (635) 20 3/4 (527) 20 (508) 13 15/16 (354) TCA1720 TCA2020 TCA2420 TCA2820 TCA3020 TCA3220 TCA3620 27 29/64 (697) 28 63/64 (736) 24 3/4 (629) 24 (610) 17 15/16 (455) TCA1724 TCA2024 TCA2424 TCA2824 TCA3024 TCA3224 TCA3624 31 29/64 (799) 32 63/64 (838) 28 3/4 (730) 28 (711) 21 15/16 (557) TCA1728 TCA2028 TCA2428 TCA2828 TCA3028 TCA3228 TCA3628 33 29/64 (850) 34 63/64 (889) 30 3/4 (781) 30 (762) 23 15/16 (608) TCA1730 TCA2030 TCA2430 TCA2830 TCA3030 TCA3230 TCA3630 39 29/64 (1002) 40 63/64 (1041) 36 3/4 (933) 36 (914) 29 15/16 (760) TCA1736 TCA2036 TCA2436 TCA2836 TCA3036 TCA3236 TCA3636 43 29/64 (1108) 44 63/64 (1143) 40 3/4 (1035) 40 (1016) 33 15/16 (862) TCA1740 TCA2040 TCA2440 TCA2840 TCA3040 TCA3240 TCA3640 51 29/64 (1307) 52 63/64 (1346) 48 3/4 (1238) 48 (1219) 41 15/16 (1065) TCA1748 TCA2048 TCA2448 TCA2848 TCA3048 TCA3248 TCA3648 ELEVATION YMBOL LEGEND: M.O. = MAONRY OPENING VALUE IN () ARE IN MILLIMETER CONVERION ##* NUMBER INDICATE DEIGN PREURE (DP) RATING WITH TANDARD GLAZING. ##** NUMBER INDICATE OPTIONAL DEIGN PREURE (DP) RATING. Note Elevations shown DO NOT have exterior trim. ubtract 1/2 (12.7) from M.O. (Masonry Opening) for Unit izes. Masonry Openings above include ill Nose, see Trim Options page for ill Nose specifications. For other Trim Options refer to the Unit izing, Rough Opening & Masonry Openings page. CALE: 1/4 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-6

INGLE UNIT M.O. BRICKMOULD M.O. ADAM/FLAT CAING ROUGH OPENING FRAME IZE DAYLIGHT OPENING 43 3/4 (1111) 46 13/16 (1189) 40 3/4 (1035) 40 (1016) 33 15/16 (862) 51 3/4 (1314) 54 13/16 (1392) 48 3/4 (1238) 48 (1219) 41 15/16 (1065) 59 3/4 (1518) 62 13/16 (1595) 56 3/4 (1441) 56 (1422) 49 15/16 (1268) 63 3/4 (1619) 66 13/16 (1697) 60 3/4 (1543) 60 (1524) 53 15/16 (1370) 20 29/64 (520) 21 63/64 (558) 17 3/4 (451) 17 (432) 10 15/16 (276) 23 29/64 (596) 24 63/64 (635) 20 3/4 (527) 20 (508) 13 15/16 (354) TCA4017 TCA4817 TCA5617 TCA6017 TCA4020 TCA4820 TCA5620 TCA6020 27 29/64 (697) 28 63/64 (736) 24 3/4 (629) 24 (610) 17 15/16 (455) TCA4024 TCA4824 TCA5624 TCA6024 31 29/64 (799) 32 63/64 (838) 28 3/4 (730) 28 (711) 21 15/16 (557) TCA4028 TCA4828 TCA5628 TCA6028 33 29/64 (850) 34 63/64 (889) 30 3/4 (781) 30 (762) 23 15/16 (608) TCA4030 TCA4830 TCA5630 TCA6030 39 29/64 (1002) 40 63/64 (1041) 36 3/4 (933) 36 (914) 29 15/16 (760) TCA4036 TCA4836 TCA5636 TCA6036 43 29/64 (1108) 44 63/64 (1143) 40 3/4 (1035) 40 (1016) 33 15/16 (862) TCA4040 TCA4840 51 29/64 (1307) 52 63/64 (1346) 48 3/4 (1238) 48 (1219) 41 15/16 (1065) TCA4048 TCA4848 ELEVATION YMBOL LEGEND: M.O. = MAONRY OPENING VALUE IN () ARE IN MILLIMETER CONVERION ##* NUMBER INDICATE DEIGN PREURE (DP) RATING WITH TANDARD GLAZING. ##** NUMBER INDICATE OPTIONAL DEIGN PREURE (DP) RATING. Note Elevations shown DO NOT have exterior trim. ubtract 1/2 (12.7) from M.O. (Masonry Opening) for Unit izes. Masonry Openings above include ill Nose, see Trim Options page for ill Nose specifications. For other Trim Options refer to the Unit izing, Rough Opening & Masonry Openings page. CALE: 1/4 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-7

INGLE UNIT M.O. BRICKMOULD M.O. ADAM/FLAT CAING ROUGH OPENING FRAME IZE DAYLIGHT OPENING 67 3/4 (1721) 70 13/16 (1799) 64 3/4 (1645) 64 (1626) 57 15/16 (1471) 75 3/4 (1924) 78 13/16 (2002) 72 3/4 (1848) 72 (1829) 65 15/16 (1675) 87 3/4 (2229) 90 13/16 (2307) 84 3/4 (2153) 84 (2134) 77 15/16 (1979) 20 29/64 (520) 21 63/64 (558) 17 3/4 (451) 17 (432) 10 15/16 (276) 23 29/64 (596) 24 63/64 (635) 20 3/4 (527) 20 (508) 13 15/16 (354) TCA6417 TCA7217 TCA8417 TCA6420 TCA7220 TCA8420 27 29/64 (697) 28 63/64 (736) 24 3/4 (629) 24 (610) 17 15/16 (455) TCA6424 TCA7224 TCA8424 ELEVATION YMBOL LEGEND: M.O. = MAONRY OPENING VALUE IN () ARE IN MILLIMETER CONVERION ##* NUMBER INDICATE DEIGN PREURE (DP) RATING WITH TANDARD GLAZING. TATIONARY UNIT Note Elevations shown DO NOT have exterior trim. ubtract 1/2 (12.7) from M.O. (Masonry Opening) for Unit izes. Masonry Openings above include ill Nose, see Trim Options page for ill Nose specifications. For other Trim Options refer to the Unit izing, Rough Opening & Masonry Openings page. CALE: 1/4 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-8

AH GLAZING OPTION INTERIOR GLAZED 11/16 3/4 13/16 1/16 1/8 1/8 AWNING AWNING AWNING // D//D 5/32//5/32 13/16 13/16 13/16 1/4 3/16 1/4 1/8 1/8 13/16 1/4 1/8 1/8 TATIONARY AH ONLY 3/16//3/16 TATIONARY AH ONLY 1/4//1/4 LAMINATED GLA CLEAR OR LOW E D//6.7L LAMINATED GLA TINTED 6.7L//D 1/16 11/16 3/4 13/16 1/8 1/8 AWNING AWNING AWNING // D//D 5/32//5/32 13/16 3/16 1/8 13/16 13/16 1/4 1/4 1/8 1/8 1/8 13/16 1/4 TATIONARY AH ONLY 3/16//3/16 LAMINATED GLA CLEAR OR LOW E D//6.7L LAMINATED GLA TINTED 6.7L//D TATIONARY AH ONLY 1/4//1/4 CALE: 3 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-9

TRIM OPTION EXTERIOR TRIM 13/4 [44] 11/4 [32] 4 9/16 [116] 1 17/32 [39] 4 9/16 [116] 4 9/16 [116] 13/8 [35] 11/2 [38] 11/2 [38] TANDARD BRICKMOULD ADAM CAING 1 5/16 [33] 4 9/16 [116] 11/2 [38] FLAT CAING ILL NOE OPTION TANDARD CALE: 3 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-10

JAMB EXTENDER OPTION 1 5/32 [29] 9/16 [14] 1 5/32 [29] 9/16 [14] 1 5/32 [29] 9/16 [14] 4 1/16 [103] 4 1/2 [114] 2 1/16 [52] 7 [178] 4 9/16 [116] 6 9/16 [167] 4 9/16 WALL 6 9/16 WALL 7 WALL 1 5/32 [29] 9/16 [14] 1 5/32 [29] 9/16 [14] 1 5/32 [29] 9/16 [14] 8 1/2 [216] 6 1/2 [165] 4 5/16 [110] 9 [229] 11 [279] 6 13/16 [173] 9 WALL 11 WALL 6 13/16 WALL CALE: 3 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-11

TANDARD MULLION OPTION TWIN AWNING OPERATING AWNING WITH FIXED OVER CALE: 3 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-12

LITE CUT INFORMATION Clad awning windows are available with removable grilles in 7/8, 1-1/8 and 1-3/8 widths for DL (imulated Divided Lites), and 5/8, 23/32, and 1 GBG (Grilles between the Glass). tandard lite cuts are rectangular. LITE CUT OPTION pecial lite cut patterns can include a wide variety of straight line and radius patterns. The illustrations shown here represent just a few of the possibilities. Rectangular, horizontal, vertical and Prairie lite patterns are available in all standard size clad windows. Uneven, diamond, radius, and Gothic lite cuts are available. subject to approval. Approvals are based on the ability to fulfill the design requirement while maintaining the construction integrity of the finished product. RECTANGULAR VERTICAL PRAIRIE UNEVEN DIAMOND RADIU BAR ALIGNMENT Alignment of divided lite muntin bars from one window to the next is often required by fine architectural design. Wood grilles, GBG (Grilles between the Glass), and imulated Divided Lites may be specified with muntin bars aligned. July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-13

DIVIDED LITE OPTION 5/16 3/8 5/16 3/8 5/16 3/8 5/16 3/8 7/8 7/8 11/8 11/8 13/8 13/8 2 5/16 2 5/16 7/8 DL 1 1/8 DL 1 3/8 DL 2 5/16 DL 5/16 3/8 5/16 3/8 5/16 3/8 5/16 3/8 7/8 7/8 11/8 11/8 13/8 13/8 2 5/16 2 5/16 7/8 DL 1 1/8 DL 1 3/8 DL 2 5/16 DL 3/16 3/16 5/16 5/8 11/16 1 5/8 GRILLE 23/32 GRILLE 1 GRILLE 3/16 3/16 5/16 5/8 11/16 1 5/8 GRILLE 23/32 GRILLE 1 GRILLE GRILLE PROFILE: 3/16 x 5/8 ALLMETAL 1021101018XX140 3/16 x 1 ALLMETAL 1020101018XX164 1/4 x 5/8 ALLMETAL 1020102018XX140 1/4 x 1 ALLMETAL 1020102018XX164 0.325 x 5/8 ALLMETAL 1020106018XX140 0.325 x 1 ALLMETAL 1020106018XX164 5.5mm x 18mm CONTOUR ALLMETAL 1020301010XX255 8mm x 25mm CONTOUR ALLMETAL 1020301018XX380 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-14

BAIC UNIT PECIFICATION Frame Clear Opening (3/4 ) q. Ft. Vent q. Ft. Crack Opg. Finished Width Height & Clear Projection Daylight Lin. Ft. Vent Floor to Top Divided Unit (in.) (in.) Opening Width (in). (in.) Opening ash Only q. Ft. Unit of ill* (in.) Lite Cut 1717 17.00 17.00 0.52 13.38 5.61 0.84 1.86 2.01 66.00 2W2H 2017 20.00 17.00 0.64 16.38 5.61 1.07 2.20 2.36 66.00 2W2H 2417 24.00 17.00 0.79 20.38 5.61 1.38 2.66 2.83 66.00 2W2H 2817 28.00 17.00 1.05 24.38 6.19 1.68 3.11 3.31 66.00 2W2H 3017 30.00 17.00 1.13 26.38 6.19 1.83 3.34 3.54 66.00 3W2H 3217 32.00 17.00 1.22 28.38 6.19 1.99 3.57 3.78 66.00 3W2H 3617 36.00 17.00 1.39 32.38 6.19 2.29 4.02 4.25 66.00 3W2H 4017 40.00 17.00 1.57 36.38 6.23 2.60 4.48 4.72 66.00 3W2H 4817 48.00 17.00 1.92 44.38 6.23 3.21 5.39 5.67 66.00 4W2H 5617 56.00 17.00 2.27 52.38 6.23 3.82 6.30 6.61 66.00 5W2H 6017 60.00 17.00 2.44 56.38 6.23 4.13 6.75 7.08 66.00 5W2H 1720 17.00 20.00 0.52 13.38 5.61 1.07 2.20 2.36 63.00 2W2H 2020 20.00 20.00 0.64 16.38 5.61 1.36 2.61 2.78 63.00 2W2H 2420 24.00 20.00 0.79 20.38 5.61 1.75 3.14 3.33 63.00 2W2H 2820 28.00 20.00 1.05 24.38 6.19 2.14 3.68 3.89 63.00 2W2H 3020 30.00 20.00 1.13 26.38 6.19 2.33 3.95 4.17 63.00 3W2H 3220 32.00 20.00 1.22 28.38 6.19 2.53 4.22 4.44 63.00 3W2H 3620 36.00 20.00 1.39 32.38 6.19 2.92 4.76 5.00 63.00 3W2H 4020 40.00 20.00 1.57 36.38 6.23 3.31 5.30 5.56 63.00 3W2H 4820 48.00 20.00 1.92 44.38 6.23 4.08 6.37 6.67 63.00 4W2H 5620 56.00 20.00 2.27 52.38 6.23 4.86 7.45 7.78 63.00 5W2H 6020 60.00 20.00 2.44 56.38 6.23 5.25 7.99 8.33 63.00 5W2H 1724 17.00 24.00 0.52 13.38 5.61 1.38 2.66 2.83 59.00 2W2H 2024 20.00 24.00 0.64 16.38 5.61 1.75 3.14 3.33 59.00 2W2H 2424 24.00 24.00 0.79 20.38 5.61 2.25 3.79 4.00 59.00 2W2H 2824 28.00 24.00 1.05 24.38 6.19 2.75 4.44 4.67 59.00 2W2H 3024 30.00 24.00 1.13 26.38 6.19 3.00 4.77 5.00 59.00 3W2H 3224 32.00 24.00 1.22 28.38 6.19 3.25 5.09 5.33 59.00 3W2H 3624 36.00 24.00 1.39 32.38 6.19 3.75 5.74 6.00 59.00 3W2H 4024 40.00 24.00 1.57 36.38 6.23 4.25 6.39 6.67 59.00 3W2H 4824 48.00 24.00 1.92 44.38 6.23 5.25 7.69 8.00 59.00 4W2H 5624 56.00 24.00 2.27 52.38 6.23 6.25 8.99 9.33 59.00 5W2H 6024 60.00 24.00 2.44 56.38 6.23 6.75 9.64 10.00 59.00 5W2H 1728 17.00 28.00 0.52 13.38 5.61 1.68 3.11 3.31 55.00 2W2H 2028 20.00 28.00 0.64 16.38 5.61 2.14 3.68 3.89 55.00 2W2H 2428 24.00 28.00 0.79 20.38 5.61 2.75 4.44 4.67 55.00 2W2H 2828 28.00 28.00 1.05 24.38 6.19 3.36 5.20 5.44 55.00 2W2H 3028 30.00 28.00 1.13 26.38 6.19 3.67 5.58 5.83 55.00 3W2H 3228 32.00 28.00 1.22 28.38 6.19 3.97 5.96 6.22 55.00 3W2H 3628 36.00 28.00 1.39 32.38 6.19 4.58 6.72 7.00 55.00 3W2H 4028 40.00 28.00 1.57 36.38 6.23 5.19 7.49 7.78 55.00 3W2H 4828 48.00 28.00 1.92 44.38 6.23 6.42 9.01 9.33 55.00 4W2H 5628 56.00 28.00 2.27 52.38 6.23 7.64 10.53 10.89 55.00 5W2H 6028 60.00 28.00 2.44 56.38 6.23 8.25 11.29 11.67 55.00 5W2H * 3/4 finished floor to top of sill height calculated from 83 header height Continued on next page July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-15

BAIC UNIT PECIFICATION Frame Clear Opening (3/4 ) q. Ft. Vent q. Ft. Crack Opg. Finished Width Height & Clear Projection Daylight Lin. Ft. Vent Floor to Top Divided Unit (in.) (in.) Opening Width (in). (in.) Opening ash Only q. Ft. Unit of ill* (in.) Lite Cut 1730 17.00 30.00 0.52 13.38 5.61 1.83 3.34 3.54 53.00 2W3H 2030 20.00 30.00 0.64 16.38 5.61 2.33 3.95 4.17 53.00 2W3H 2430 24.00 30.00 0.79 20.38 5.61 3.00 4.77 5.00 53.00 2W3H 2830 28.00 30.00 1.05 24.38 6.19 3.67 5.58 5.83 53.00 2W3H 3030 30.00 30.00 1.13 26.38 6.19 4.00 5.99 6.25 53.00 3W3H 3230 32.00 30.00 1.22 28.38 6.19 4.33 6.40 6.67 53.00 3W3H 3630 36.00 30.00 1.39 32.38 6.19 5.00 7.22 7.50 53.00 3W3H 4030 40.00 30.00 1.57 36.38 6.23 5.67 8.03 8.33 53.00 3W3H 4830 48.00 30.00 1.92 44.38 6.23 7.00 9.66 10.00 53.00 4W3H 5630 56.00 30.00 2.27 52.38 6.23 8.33 11.30 11.67 53.00 5W3H 6030 60.00 30.00 2.44 56.38 6.23 9.00 12.11 12.50 53.00 5W3H 1736 17.00 36.00 0.52 13.38 5.61 2.29 4.02 4.25 47.00 2W3H 2036 20.00 36.00 0.64 16.38 5.61 2.92 4.76 5.00 47.00 2W3H 2436 24.00 36.00 0.79 20.38 5.61 3.75 5.74 6.00 47.00 2W3H 2836 28.00 36.00 1.05 24.38 6.19 4.58 6.72 7.00 47.00 2W3H 3036 30.00 36.00 1.13 26.38 6.19 5.00 7.22 7.50 47.00 3W3H 3236 32.00 36.00 1.22 28.38 6.19 5.42 7.71 8.00 47.00 3W3H 3636 36.00 36.00 1.39 32.38 6.19 6.25 8.69 9.00 47.00 3W3H 4036 40.00 36.00 1.57 36.38 6.23 7.08 9.67 10.00 47.00 3W3H 4836 48.00 36.00 1.92 44.38 6.23 8.75 11.64 12.00 47.00 4W3H 1740 17.00 40.00 0.52 13.38 5.61 2.60 4.48 4.72 43.00 2W3H 2040 20.00 40.00 0.64 16.38 5.61 3.31 5.30 5.56 43.00 2W3H 2440 24.00 40.00 0.79 20.38 5.61 4.25 6.39 6.67 43.00 2W3H 2840 28.00 40.00 1.05 24.38 6.19 5.19 7.49 7.78 43.00 2W3H 3040 30.00 40.00 1.13 26.38 6.19 5.67 8.03 8.33 43.00 3W3H 3240 32.00 40.00 1.22 28.38 6.19 6.14 8.58 8.89 43.00 3W3H 3640 36.00 40.00 1.39 32.38 6.19 7.08 9.67 10.00 43.00 3W3H 4040 40.00 40.00 1.57 36.38 6.23 8.03 10.77 11.11 43.00 3W3H 4840 48.00 40.00 1.92 44.38 6.23 9.92 12.95 13.33 43.00 4W3H 1748 17.00 48.00 0.52 13.38 5.61 3.21 5.39 5.67 35.00 2W4H 2048 20.00 48.00 0.64 16.38 5.61 4.08 6.37 6.67 35.00 2W4H 2448 24.00 48.00 0.79 20.38 5.61 5.25 7.69 8.00 35.00 2W4H 2848 28.00 48.00 1.05 24.38 6.19 6.42 9.01 9.33 35.00 2W4H 3048 30.00 48.00 1.13 26.38 6.19 7.00 9.66 10.00 35.00 3W4H 3248 32.00 48.00 1.22 28.38 6.19 7.58 10.32 10.67 35.00 3W4H 3648 36.00 48.00 1.39 32.38 6.19 8.75 11.64 12.00 35.00 3W4H 4048 40.00 48.00 1.57 36.38 6.23 9.92 12.95 13.33 35.00 3W4H 4848 48.00 48.00 1.92 44.38 6.23 12.25 15.59 16.00 35.00 4W4H * 3/4 finished floor to top of sill height calculated from 83 header height July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-16

VENT PROJECTION NARROW OPERATOR Frame Width under 21 23 11 1/4 [285] Vent Projection Roto type hardware TANDARD OPERATOR Frame Width 21 and over 26 15 1/2 [394] Vent Projection Roto type hardware AWNING VENT PROJECTION The drawings above reflect full operation. Dimensions and angles above are approximate and will vary due to frame height. July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-17

UNIT IZING, ROUGH OPENING & MAONRY OPENING TANDARD OFFERING DRIP CAP & NAILING FLANGE UNIT IZE FRAME = UNIT IZE FIXED OPERATOR GENERAL NOTE: UNIT WITH NO TRIM AND ILL NOE: UNITIZE=FRAMEIZE UNITIZEIALWAYTHE EXTREME IZE OF THE WINDOW WITH OR WITHOUT TRIM (DRIP CAP & NAILING FLANGE ARE NOT ADDED TO ANY UNIT IZING) MAONRY OPENING: MAONRY OPENING I ALWAY 1/2 OVER THE UNIT IZE OF THE WINDOW ROUGH OPENING: ROUGHOPENINGIALWAY3/4 OVER FRAME IZE OF THE WINDOW HORIZONTAL ROUGH OPENING 3/4 [19] UNIT IZE 2 BRICKMOULD FRAME+11/2 [38] UNIT IZE 31/2 FLATCAING & ADAM CAING FRAME + 3 [76] EXTERIOR TRIM OFFERING WITHOUT ILL NOE EXTERIOR TRIM ON ALL 4 IDE UNIT IZE 31/2 FLATCAING & ADAM CAING FRAME + 6 [152] UNIT IZE 2 BRICKMOULD FRAME + 3 [76] UNIT IZE 2 BRICKMOULD FRAME + 3 [76] UNIT IZE 31/2 FLATCAING & ADAM CAING FRAME + 6 [152] OPERATOR FIXED UNIT IZE FRAME = UNIT IZE 3/8 [10] 3/8 [10] NON-TANDARD UNIT IZING EXTERIOR TRIM OFFERING 12 [305] VERTICAL ROUGH OPENING 18 [457] FRAME TO TRIM DIMENION 3 [76] 31/2 FLAT& ADAM CAING 11/2 [38] BRICKMOULD HORIZONTAL ECTION TRIM OFFERING ABOVEARETHEAME WITH OR WITHOUT ILL NOE TYPICAL FOR HEAD, ILL & IDE July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-18

OPERATING UNIT 5 13/16 1 3/16 41/2 2 7/16 2 5/16 15/16 1 9/16 2 1/16 3/4 15/8 1 9/16 9/16 Unit ize ash ize Glass ize Daylight Opening 1/8 creen ize Frame ize Rough Opening 3/4 9/16 1 9/16 2 9/16 2 5/16 15/16 1 3/16 21/2 1 9/16 2 1/16 4 9/16 5 13/16 VERTICAL ECTION CALE: 6 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-19

OPERATING UNIT 3/8 Rough Opening Frame ize 15/8 creen ize 15/8 3/8 2 1/16 2 1/16 4 9/16 4 9/16 5 13/16 1 9/16 1 9/16 5 13/16 21/2 21/2 15/16 1/8 15/16 3/4 1 3/16 1 3/16 9/16 9/16 Daylight Opening 1 9/16 Glass ize 1 9/16 2 5/16 ash ize 2 5/16 Unit ize HORIZONTAL ECTION CALE: 6 = 1 July 2007 JELD-WEN reserves the right to change specifications without notice. Page 3-20