Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria

Similar documents
GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Comparison of the Novel ColiPlate

Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

Optimum Membrane Structures for Growth of Coliform and Fecal Coliform Organisms

Bacterial Interference with Coliform Colony Sheen Production on

Addressing challenges associated with the detection of faecal coliform organisms in water matrices. Neil Leat Rand Water Date 30/09/2014

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

REC. Interpretation Guide. Rapid E. coli/coliform Count Plate

COLILERT - WHAT'S AL THE FUSS ABOUT? Elizabeth Hanko. Elizabeth Hanko, Senior Consultant. AWT, Victoria

Comparison of Nine Brands of Membrane Filter and the

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation

The Microbiological Survey of Potential Water Borne Pathogens in Fresh Water Springs of the Selected Community Located in the Upolu Island, Samoa

NordVal International / NMKL c/o Norwegian Veterinary Institute PB 750 Sentrum, 0106 Oslo, Norway

Bacterial Quality of Crystalline Rock and Glacial Aquifers in New England

Pr oject Summar y. Survey of the prevalence of Escherichia coli O157:H7 on the surface of subprimal cuts of beef during winter months (Phase I)

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

Interpretation Guide. Coliform Count Plate

Chromocult Coliform Agar acc. ISO

Influence of Diluents, Media, and Membrane Filters on Detection of Injured Waterborne Coliform Bacteria

Food Microbiological Examination: Enumeration of Coliforms

Loyalsock Creek Bacterial Coliforms. Presented By: Dr. Mel Zimmerman Clean Water Institute Lycoming College Matthew Bennett Jim Rogers

Detection of Total Coliforms, Escherichia coli, and

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

Portland Water District Sebago Lake Monitoring Programs Lower Bay Bacteria Monitoring Presenting data from 1977 to 2018 Laurel Jackson

Interpretation Guide

Fecal Coliform Bacteria Monitoring for the Sleepy Creek Watershed Incremental 319 Project Final Report

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Evaluation of Membrane Filters for the Determination of Numbers of Coliform Bacteria in Waterl

r., C D C5,) -I2ET dun 241,%3 Sco C)6 C-.) TISIA TECHNICAL DOCUMENTARY REPORT AAL-TDR-6Z-55 AAL- TDR-62-55

Project Summary. Principal Investigators: Lawrence D. Goodridge 1 ; Phil Crandall 2, and Steven Ricke 2. Study Completed 2010

Enumeration of Total Coliforms

Interpretation Guide

Productivity. Technician. Maximized. Interpretation Guide

- *".' , / SI'UDIES ON BA4CrrERIAL INDICATORS OF IN DKINKING WA'I'EK

Kit Information 3. Sample Preparation 4. Procedure 4. Analysis of Results 5. Quality Control 6. Disposal 6. Technical Support 6. Order Information 6

A Study of the Role of Air-borne Particulates as the Cause of Unexplained Coliform Contamination in Drilled Wells.

HOW TO IMPROVE HIGH-FREQUENCY BUS SERVICE RELIABILITY THROUGH SCHEDULING

Water Quality Trends for Conscience Bay

COLIFORM BROTH. Fecal Coliform Broth. M-FC BROTH without ROSOLIC ACID (Blue background)

Holding Effects on Coliform Enumeration in Drinking

Drinking Water Microbiology 2010:2, September

3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader

Bacterial Occurrence in Kitchen Hand Towels

There are 7 kinds of unique dry medium for hygienic testing and detection of food poisoning bacteria.

Tufts University Water: Systems, Science, and Society (WSSS) Program

Indicator organisms. !Group of microorganisms use to reflect the quality and safety of a process food product

IDEXX Summary. D P Sartory and C Allaert Vandevenne

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Injured Coliforms in Drinking Water

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

No Longer Fond of the Local Pond

3M Food Safety 3M Petrifilm Plates and Reader. Simply. Prompt. Precise. Productive.

LAKE HURON BEACH STUDY

Protecting Consumers. Improving lab efficiency. 3M Petrifilm Plates and Reader

Pr oject Summar y. Impact of ground beef packaging systems and temperature abuse on the safety of ground beef

Comparison of Enterococci and Coliform Microorganisms in

Laboratories & Consulting Group

MICROBIAL ANALYSIS OF RAW AND BOILED MILK SOLD AT BARATON CENTER IN NANDI COUNTY, KENYA

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

Statistical Evaluation of BMP Effectiveness in Reducing Fecal Coliform Impairment in Mermentau River Basin

BACTERIAL CONTAMINATION OF WATER WELLS AND SPRINGS

CITY OF LYNDEN STORMWATER MANAGEMENT PROGRAM REPORT MARCH 1, 2016

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

\AN EVALUATION OF A MODIFIED MEMBRANE FILTER PROCEDURE FOR ENUMERATING STRESSED FECAL COLIFORMS IN CHLORINATED SEWAGE EFFLUENT~ by Steven Paul"Clark~

Proficiency Testing FINAL REPORT Check sample program 16CSP02 February 2016

Sampling for Microbial Analysis

Pathogenic Naegleria from Thermal Springs

HEATHROW COMMUNITY NOISE FORUM

Coliform Species Recovered from Untreated Surface Water

Comparative Analysis of Modeling Techniques for Coliform Organisms in Streams

Project Summary. Principal Investigators: Chance Brooks, Mindy Brashears, Mark Miller, Alejandro Echeverry, and Cassandra Chancey

Bacteriological testing of water

Temperature affects the silicate morphology in a diatom

E. coli and Coliform Bacteria Levels of Edgewood s Watershed Katie Schneider and Leslie Reed

Little Venice Water Quality Monitoring 2002 Annual Report

Operational safety of urine diversion toilets in Durban, South Africa

Jonathan Howarth Ph.D and Tina Rodrigues BS Enviro Tech Chemical Services Modesto, CA 95258

Systems. have been made previously to examine the interrelationship

VALIDATION OF DRY-AGING AS AN EFFECTIVE INTERVENTION STEP AGAINST ESCHERICHIA COLI O157:H7

Proficiency Testing. Drinking Water Microbiology. September Tommy Šlapokas NFA PT

User friendly microbial detection! Sanita-kun R =The ready-to-use cultural medium sheet for the microbial detection =

Fecal Coliforms Increase in a Storm Drain Fed Pond After Rain Events

Estimates of the Economic Importance of Tourism

Water Quality Trends for Patchogue Bay

HARLECO Dyes & Stains Microscopy products to support your success

Convenient Media Solutions For food and water testing

Measuring Productivity for Car Booking Solutions

Analysis of Indicator Bacteria in NJ Dead-end Lagoons. Michael Callaghan Gasbarro Mentor: Dr. Kathryn Goddard

California Leafy Greens Research Board Final Report April 1, 2008 to March 31, 2009

New Medium for Improved Recovery of Coliform Bacteria from Drinking Water

HEATHROW COMMUNITY NOISE FORUM. Sunninghill flight path analysis report February 2016

Revealed Preference Methods

FECAL COLIFORM MONITORING IN GRAYS HARBOR COUNTY: SUMMARY REPORT OF MONITORING RESULTS FOR

FINAL Water Year 2012 Bacteria Sampling Report for the Klamath River Estuary

CERTIFICATE OF ACCREDITATION

Transcription:

APPLIED MICROBIOLOGY, Sept. 1973, p. 332-336 Copyright 0 1973 American Society for Microbiology Vol. 26, No. 3 Printed in U.S.A. Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria WILLIAM G. PRESSWOOD AND LYNN R. BROWN Division of Environmental Planning, Tennessee Valley Authority, Chattanooga, Tennessee 37401 Received for publication 4 May 1973 Tests of two leading brands of membrane filters used for enumerating fecal coliform bacteria showed that Gelman GN-6 filters recovered statistically more colonies of bacteria than did Millipore HAWG 047SO filters from pure cultures incubated at either 35 C (the optimal growth temperature) or 44.5 C (the standard temperature for the fecal coliform test). Standard membrane filter procedures with M-FC broth base were used to enumerate the organisms. Densities of colonies incubated on Gelman filters at 44.5 C averaged 2.3 times greater than those on Millipore filters. Plate counts of the bacteria at both temperatures indicated that incubation at 44.5 C did not inhibit propagation of fecal coliform bacteria. For the pour plates, M-FC broth base plus 1.5% agar was used. This modified medium compared favorably to plate count agar for enumerating Escherichia coli. At 35 and 44.5 C, colony counts on Gelman filters agreed closely with plate counts prepared concurrently, but Millipore counts were consistently lower than plate counts, especially at 44.5 C. Comparative analyses of river water for fecal coliform bacteria by the membrane filter technique gave results comparable to those for the pure cultures. The pour plate procedure is perhaps considered by most bacteriologists the best method for determining the densities of viable bacteria. The most probable number procedure produces a wide range of 95% confidence limits, and results from this technique are often erratic and overestimate the true density of bacteria. Results from the membrane filter procedure approach the results of the pour plate procedure more nearly than do any of the other methods suggested for determining coliform bacteria. The membrane filter technique for enumerating fecal coliform bacteria was entered in Standard Methods for the Examination of Water and Wastewater (1) as a standard procedure in 1971. This technique requires that cultures be incubated at 44.5 ± 0.2 C for 24 h in a constant-temperature water bath. The standard method does not, however, specify a particular commercial brand of membrane filter (1). The user may choose from the products of several different manufacturers. However, when we began using a second commercial brand of membrane filter (Gelman GN-6) interchangeably with the brand previously used in routine analyses (Millipore HAWG 047SO), we noticed that although colonies grown on Millipore filters appeared larger, 332 smoother, and more glistening than those grown on Gelman filters, which were generally smaller, unevenly blue, and often dull, there nevertheless was a pronounced increase in colony counts on the Gelman filters. Later, we noticed that the colony counts on the Gelman filters agreed more closely with colony counts on pour plates than did those on the Millipore filters. Colony counts on membrane filters have been compared with those on pour plates by several investigators. Henderson (3) compared membrane filter colony counts of coliform bacteria incubated on m-endo MF broth at 35 C with plate counts and found excellent agreement between the two methods. Geldreich et al. (2) reported an average 88% recovery of fecal coliform bacteria on the membrane filter with fecal-coliform-organism medium (M-FC) at 44.5 C based on counts of pour plates incubated at 35 C with tryptose-glucose-extract agar. However, Levin et al. (4) found no agreement between counts on membrane filters and pour plates with Escherichia coli ATCC strain 8739. For the membrane filter medium they used m-enrichment broth followed by brilliant green fuchsin broth, or m-endo broth for some analyses, and nutrient agar for the pour plates.

VOL 26, 1973 COMPARISON OF TWO MEMBRANE FILTERS 333 In an attempt to account more completely for the differences we had observed in our analyses, we made an extensive comparative study of the recovery of pure cultures of 25 strains of E. coli incubated on Millipore and Gelman membrane filters and on pour plates at 35 C, the temperature for optimal growth of fecal coliform bacteria, and 44.5 C, the standard temperature for the fecal coliform test. This study was designed to investigate the possible effect of the higher temperature on bacterial growth and to provide a large number of data on enough different strains of E. coli to reveal any trend in the comparative performances of the two filters or in their agreement with the results of the pour plate procedure. plate count agar for its ability to recover E. coli by doing five replicate plate counts at 35 C with each medium for three of the pure cultures. The means were not significantly different at the 5% level. Cell suspensions. Cell suspensions of E. coli were made from cultures incubated 24, 48, or 72 h in EC medium at 35 C. For most of this work, we added 0.01 ml of stock culture to a 99-ml phosphate buffer water blank and then diluted this 1: 1,000 in sterile phosphate buffer solution. To keep all cell suspensions within a workable range of bacterial concentrations, however, cultures of strains that grew exceptionally well in EC broth and reached very high densities required greater dilution. Similarly, cultures incubated for 24 h were usually at the peak of the growth cycle and had to be diluted 1:10,000 to reduce the bacterial concentration to the countable range. Procedure. For each of the 25 pure strains of E. MATERIALS AND METHODS coli, we prepared 20 replicate cultures on Millipore filters, on Gelman filters, and on pour plates. For the Membrane filters. This investigation was limited membrane filter cultures, 1 ml of the cell suspension to a comparison of only two commercial brands of was filtered through each filter. A Millipore filtering 0.45-Mgm porosity membrane filters, chosen because apparatus was used for all filtrations. Pour plates they are perhaps the most widely used brands sold in were prepared on the agar-modified medium according to standard procedures (1). The filter cultures and the United States: Millipore HAWG 047SO (Millipore Corp., Bedford, Mass.), sterilized with ethylene pour plates were prepared alternately to prevent bias. oxide; and Gelman GN-6, 63077 (Gelman Instrument Of the 20 replicate samples for each lot, 10 were Co., Ann Arbor, Mich.), sterilized in an autoclave. incubated in an environmental incubator at 35 4 1 C Both brands of filters were sterilized by the manufacturer. Three different lot control numbers of Millipore Colonies were counted under a stereomicroscope at a and 10 were incubated at 44.5 i 0.2 C in a water bath. and two of Gelman were used. magnification of 7x. Cultures. The fecal coliform group is predominantly a conglomerate of many strains of Escherichia with a smaller number of Enterobacter RESULTS and Klebsiella. Individual strains of the fecal coliform The resulting data were analyzed statistically group respond differently to different substrates and by linear regression analysis, by the t test, and temperatures of incubation. For our comparison of by the coefficient of variation. These data were filters, we judged it better to test many strains of used as the basis for three comparisons. To Escherichia individually and to draw conclusions determine the effects of the higher incubation from the results of the composite of microorganisms rather than use one strain of E. coli. temperature on enumeration of bacteria, the To obtain such a diverse population, we isolated 20 densities of bacteria incubated at 35 and 44.5 C strains of fecal coliform bacteria from river water at were compared within each lot of replicates different time periods from various sources within the (Millipore compared with Millipore, Gelman Tennessee Valley, and five strains directly from with Gelman, pour plates with pour plates) domestic sewage by selecting typical blue colonies (Fig. 1). To determine differences between the cultured at 44.5 C on membrane filters with M-FC membrane filters, colonial densities on Millipore filters were compared with those on broth base medium. The microorganisms were streaked onto eosin methylene blue agar to check for purity, and a characteristic E. coli colony was picked Gelman filters incubated at corresponding temperatures (Fig. 2). To determine the relative and grown in elevated coliform (EC) medium at 44.5 C to confirm gas production. Stock cultures were accuracy of results on the different membrane maintained at 35 C in EC medium. IMViC classifications were done on each culture by standard proce- were compared with those on pour plates incu- filters, densities on Millipore and Gelman filters dures (1). Only recently isolated bacteria were used in bated at corresponding temperatures (Fig. 3 the investigation, and all were identified as E. coli and 4). type I (IMViC + + - -). Finally, to determine whether the results Culture media. For the membrane filter tests, from the studies of pure cultures were characteristic of results that might be expected during M-FC broth base plus 0.01% rosolic acid was used as the recovery medium. To provide a similar growth medium for the pour plate comparisons, M-FC broth routine use of these membrane filters for typical base plus 1.5% agar was autoclaved, 0.01% rosolic acid water quality analyses, Millipore filters were was added, and the medium was cooled to about 50 C compared with Gelman filters for their efficiency in recovering fecal coliform bacteria before use. This modified medium was compared with from

or/ ~~~~~ ' ~~~~~~MILLIPORE - ~~PLATE 334 PRESSWOOD AND BROWN APPL. MICROBIOL.' of 1.0 and which would result if, for either membrane filters or the plate counts, the means at 35 and 44.5 C were the same. The extent to which each regression line falls below the line of equality shows the decrease in colonial densities at the higher temperature. Comparison of the q / < ~~~~-GLMAN regression coefficient for the plate count line (0.976) and the regression coefficient of the CE 100 equality line by the t test shows no statistical / difference at the 5% significance level in counts on pour plates incubated at 35 and 44.5 C. The regression lines for bacteria cultured on membrane filters were statistically different from BACTERIA/ml AT 35 C FIG. 1. Membrane filter and equality at the plate counts 5% of fecal significance level. However, coliform bacteria at 35 and 44.5 C. Regression coefficients: plate counts = 0.976, Gelman counts = 0.855, on Millipore filters than for those on Gelman this difference was markedly greater for cultures and Millipore counts = 0.319. filters. The slope of the regression line for Gelman filters (0.855) is approximately 2.7 times greater than that for Millipore filters (0.319). Uj 300 - LINE OF EQUALITY ar U_ ~~~~~~~~~35 C 100 44.5 C co BACTERIA/ml ON GELMAN FILTERS FIG. 2. Comparison of fecal coliform bacterial densities on Millipore and Gelman membrane filters at 35 and 44.5 C. Regression coefficients: Millipore counts = 0.905 at 35 C and 0.441 at 44.5 C. samples of river water (see Table 3). The two brands of filters were alternated during filtrations. The data used for calculating the regression lines in Fig. 1 through 4 are the mean counts of 10 replicates at 35 C and 10 replicates at 44.5 C for Gelman and Millipore membrane filters and pour plates. The mean values are not shown on the figures but are listed in Table 1. The regression lines with zero intercept were calculated by the method of least squares. This method fits data to an optimized line by the equation Y = bx, where b is the regression coefficient or slope, Y is the dependent variable, and X is the independent variable. The results of the enumerations of fecal coliform bacteria at 35 and 44.5 C on Gelman and Millipore membrane filters and by the pour plate procedure are compared in Fig. 1. Each regression line is compared with the equality line, which has a regression coefficient or slope 300 LINE OF EQUALITY 0 -GELMAN a X-// MILLIPORE o100 I =) BACTERIA/ml ON M-FC AGAR FIG. 3. Comparison of fecal coliform bacterial densities on Gelman and Millipore membrane filters with those on plate counts at 35 C. Regression coefficients: Gelman counts = 0.967, and Millipore counts = 0.826. 300 LINE OF EQUALITY--\ _j, C 100 ao ~~~~~~~GELMAN i----millipore BACTERIA/ml ON M-FC AGAR FIG. 4. Comparison of fecal coliform bacterial densities on Gelman and Millipore membrane filters with those on plate counts at 44.5 C. Regression coefficients: Gelman counts = 0.845, and Millipore counts = 0.280.

VOL. 26, 1973 COMPARISON OF TWO MEMBRANE FILTERS 335 TABLE 1. Mean counts of 10 replicates of 25 strains of fecal coliform bacteria on membrane filters and by plate counts No. of bacteria per ml Culture no. 35 C 44.5 C Plate Milli- Gel- Plate Milli- Gel pore man pore man 1 33.0 29.3 31.2 32.9 3.9 28.3 2 135.4 146.2 183.6 129.5 13.7 157.1 3 272.0 247.1 247.3 261.5 81.5 224.2 4 142.9 154.7 167.6 152.8 28.1 146.0 5 97.1 97.7 100.4 81.2 7.8 22.4 6 71.7 70.6 77.8 75.4 30.2 75.1 7 256.2 257.9 276.1 270.5 78.7 244.2 8 359.2 378.3 396.8 357.1 68.7 344.7 9 136.4 125.7 140.6 122.5 10.3 125.0 10 141.7 127.2 138.7 49.5 35.8 115.2 11 45.7 48.1 47.2 49.2 21.6 38.4 12 139.9 123.0 136.4 138.2 51.7 125.6 13 145.0 130.4 146.2 147.5 77.1 130.0 14 101.2 91.6 104.7 99.4 23.5 90.1 15 171.4 76.2 150.4 163.7 39.6 114.5 16 256.6 259.9 248.3 258.2 153.1 251.1 17 69.7 69.5 68.9 74.5 19.5 62.3 18 44.4 43.3 51.2 50.0 9.6 36.8 19 216.3 127.5 206.1 229.2 145.0 210.6 20 198.4 202.9.0 207.5 69.8 182.7 21 150.3 113.2 160.2 97.6 0.2 35.9 22 158.3 146.1 159.4 140.6 8.7 93.3 23 245.1 228.8 245.4 238.1 101.8 220.5 24 111.6 15.3 58.7 105.1 0.5 36.9 25 356.0 114.8 245.8 366.0 20.8 212.4 When Gelman cultures were compared with Millipore cultures at 35 and 44.5 C, results showed that larger numbers of colonies were recovered on Gelman filters (Fig. 2). If the bacterial populations on the two filters were not different, the regression lines would coincide with the line of equality. Since the regression lines are below the equality line at both temperatures, the indication is that colonial densities on Millipore filters were consistently lower than those on Gelman filters. This difference occurred at both temperatures, but the disparity between the filters was greater by a factor of 2.3 at 44.5 C. The differences were statistically significant at the 5% level. Bacterial colony counts on Gelman and Millipore filters were compared with colony counts on pour plates at 35 C (Fig. 3) and at 44.5 C (Fig. 4). The regression lines derived frqm the comparison of counts on Gelman filters and pour plates at both 35 and 44.5 C are nearer to the line of equality than are the corresponding regression lines for Millipore filters and pour plates. A t test comparison of the regression coefficients for cultures on Gelman and Millipore filters to the regression coefficient for the line of equality showed that colony counts on Gelman filters were not statistically different from counts on pour plates at 35 C. Colony counts on Millipore filters were statistically different from the line of equality at this temperature. Colony counts on Gelman and Millipore filters were statistically different from counts on pour plates at 44.5 C. On the average, however, colony counts on pour plates were 3.6 times greater than those on corresponding Millipore filters but only 1.2 times greater than those on Gelman filters. The coefficient of variation shows the degree of precision in the method of bacterial enumeration. The results with the lowest coefficient of variation are the most precise. Table 2 lists the average coefficients of variation for the 25 cultures at 35 and 44.5 C. Counts on pour plates and Gelman filters at 35 C had the lowest average coefficient of variation (0.09). Counts on pour plates at 44.5 C had an average coefficient of variation of 0.10. Cultures incubated on Gelman filters at 44.5 C had an average coefficient of variation of 0.14, whereas those incubated on Millipore filters at this temperature had the largest coefficient of variation of 0.48. Gelman and Millipore membrane filters were compared in a typical application for efficiency in recovering fecal coliform bacteria by analyzing samples of river water collected near the laboratory at Tennessee River mile 464.0. The elevated temperature fecal coliform test was used to determine the fecal coliform density in the water. Fecal coliform bacterial densities on Millipore filters were only 53.1% of those on the Gelman filters (mean of 3 runs) (Table 3). These results compare favorably with the results of the analyses of pure cultures. DISCUSSION The lack of any significant statistical difference for the results of the comparison of pour plates incubated at 35 and 44.5 C (Fig. 1) indicates that the higher temperature is not in TABLE 2. Average coefficient of variation at 35 and 44.5 C for Gelman and Millipore cultures and for plate countsa Culture Coefficient of variation 35C 44.5C Plate 0.09 0.10 Gelman 0.09 0.14 Millipore 0.13 0.48 acalculated from the sum of the coefficients of variation for each of the 25 strains of bacteria.

336 PRESSWOOD AND BROWN APPL. MICROBIOL. TABLE 3. Comparison of Gelman and Millipore membrane filters for recovery of fecal coliform bacteria from river water Date of No. of bacteria per mla Loss on samplemilpr collection Gelman Millipore Loreon 25 Sept 72 88.6 43.4 51.0 26 Sept 72 134.2 63.0 53.0 28 Sept 72 60.4 27.0 55.3 Mean loss (%) 53.1 amean of five filtrations. itself detrimental to the propagation of E. coli. Therefore, the statistical difference revealed for cultures incubated on the membrane filters at the two temperatures (Fig. 1) indicates that the detrimental effect of propagation of the fecal coliform bacteria is attributable to the filters rather than to the increased temperature. The greater difference between the equality line and the regression line for the results of cultures on Millipore filters, as compared with that for Gelman filters, therefore suggests an effect of some difference in the characteristics of the two brands of filters that increases with increasing temperature or that may be related to the method of sterilization. Although all cellulose brands of membrane filters are basically similar, additives such as wetting agents and inks used for grid markings vary. These or other compounds such as ethylene oxide residues contained in the filters could possibly be toxic to bacteria or become toxic at 44.5 C and account for the smaller number of colonies at this temperature. Such an effect is also suggested by the comparison of results for the two filters at each temperature (Fig. 2), since the difference occurred at both temperatures but was greater at 44.5 than at 35 C. Gelman and Millipore filters appear to have different ph values. Gelman filters are blue whereas Millipore filters are amber when placed on M-FC medium. The acid-base indicator system in M-FC medium gives a blue color at acidic ph ranges. While it seems unlikely that the difference in ph is responsible for the disparity in the number of colonies on the two filters, this likelihood should be investigated. Regression analysis also showed that results with Gelman filters were not statistically different from results with pour plates at 35 C, whereas those with Millipore filters were statistically different. And although results with both filters were statistically different from those with pour plates at 44.5 C, the difference was far greater for Millipore filters than for Gelman filters. Temperature alone had no significant effect on the precision of results, for the average coefficients of variation for pour plates at 35 and 44.5 C were 0.09 and 0.10, respectively. The use of the membrane filter procedure did affect precision at the higher temperature, however, and this effect was greater for the Millipore filters than for the Gelman filters. Gelman filters produced results that equaled the precision of pour plates at 35 C (average coefficient of variation 0.09) but were less precise (0.14) at 44.5 C. The precision of results for Millipore filters at 35 C (0.13) did not approach the precision of pour plates and Gelman filters at 35 C and, in fact, was little better than that for Gelman filters at 44.5 C. The least precise results were those for Millipore filters at 44.5 C. The results from the practical analysis of river water suggest that the results of the studies of the 25 pure cultures indicate the typical performance of these two brands of filters. The clear indication that Gelman filters recover significantly more fecal coliform bacteria than do Millipore filters suggests the need for further investigation of these and other brands of membrane filters to determine their relative efficiencies and to identify the reason for the difference in the extent of their effects on the propagation of bacteria. Since one obvious difference in the characteristics of the Millipore and Gelman filters is the method of sterilization, this may be the next logical step in this investigation. In any case, examination of the results in Table 1 make it clear that no such investigations should be based on results for a single strain of bacteria. The difference in results for any one strain may be great or small; therefore, generalizations about relative performance can only be based upon an investigation of a large number of different strains. ACKNOWLEDGMENTS We thank Don Rucker for editing the manuscript, Shirley Ray for the statistical analyses, Isaac Jones for his technical assistance, Ed Richards for the drawings, and Janice Johnson for her patience in typing the paper. LITERATURE CITED 1. American Public Health Association. 1971. Standard methods for the examination of water and wastewater, 13th ed. American Public Health Association Inc., New York. 2. Geldreich, E. E., H. F. Clark, C. B. Huff, and L. C. Best. 1965. Fecal coliform organism medium for the membrane filter technique. J. Amer. Water Works Ass. 57:208-214. 3. Henderson, W. L. 1959. Studies on the use of membrane filters for the estimation of coliform densities in sea water. Sewage Ind. Wastes 31:78-91. 4. Levin, G. W., V. L. Stauss, and W. C. Hess. 1961. Rapid coliform organism determination with C14. J. Water Pollut. Contr. Fed. 33:1021-1037.