Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

Similar documents
12V, Ten channel light effect generator

Installation and Maintenance Manual

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Blue Series Hot Melt Hose with RediFlext II Hanger System

HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay

212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Model Number Structure

UNODOS + / FLOCDOS +

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

General-purpose Relay

AWNING CONTROL KIT 98GCK-33B

General-Use Auto-Tuning HPX-T Series

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Plug-in/solder terminals with LED indicator

Electronic Temperature Controls

Genesis. Side Burner Accessory Installation. Step 3. Step 1. Step 2. For use with Genesis Gas Barbecues Only

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Ultraflow Compact Housing and Winter Kit

General Purpose High Power PCB Relays

Data Sheet for Precision Potentiometer

Engineering Design Assurance Test Report ( S )

Crystal Compact Housing and Winter Kit

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

Primrose Awnings - Full Cassette Manual & Electric Instructions

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

Data Sheet for Precision Potentiometer

Engineering Design Assurance Test Report ( S )

Amphenol RF Interconnects TNC 31 Series Threaded Lock RF Connector System Materials

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

AFC-50 Automatic French Fry Cutter Instruction Manual

12V MOTION SENSOR 98GC779G INSTALLATION & PROGRAMMING GUIDE REV RV AWNING PRODUCTS

INFRARED BURNER KIT INSTRUCTIONS

Model. Oasis Automatic and Manual RV Door Awning System INSTALLATION & OPERATING INSTRUCTIONS

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

Primrose Awnings Half Cassette Manual & Electric Instructions

Primrose Awnings Full Cassette Manual & Electric Instructions

30M AUTOMATIC HOSE REEL Professional Series INSTRUCTION MANUAL

t420 Barbecue Assembly Manual

Toyostove Error Code EE 2 (EE 6)

Crystal Filter Housing

How to make a solar campfire

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

Primrose Awnings Half Cassette Manual & Electric Instructions

Accessories. LED AWNING LIGHT RGB External LED light available in white or multi-colored (RGB).

AUTO REWIND HOSE REEL USER MANUAL

Brooks Fire Pit Table. Installation Instructions for Brooks Fire Pit Table BRK-1224

Induction hardened cutting knives for long life. Thick, exceptionally tough, high-dielectric white inner coating is bonded to the tool

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

a Nexans company Catalogue 2009

Safety Interlock Switches

STRAIGHT BLADE RECEPTACLES

Insulated Tools. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Gas Go Anywhere /23/01

GAS STOVE GUARD for natural gas and propane stoves

HEATER POWER CONTROLLER

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

S420 Barbecue Assembly Manual

SECTION I-1. Type: 1812-AC. Fuel: Air-Gas.

CREW REST MODULE CMM DESCRIPTION AND OPERATION

The Good, The Bad and The Ugly. ACøC Alpha 76pa. One Man s Modernization - or Unforgivable Butchering - of a Classic Workhorse Amp

12V DIRECT RESPONSE. Installation Manual

Optional Controls (Depends which set was purchased) Set A (Remote control kit)

TANK MONITOR MODEL # (12V DC) (24V DC) (32V DC) OPERATION AND INSTALLATION INSTRUCTIONS

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

INFRARED BURNER KIT INSTRUCTIONS

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

Tools. For safety and easy faucet replacement, San-Ei recommends the use of the following helpful tools:

BASEBALL PEG. Remove the three Philips head screws with a 4mm screw driver. Requires (3AA) Batteries

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Fogly. GlammFire. GlammFire. Materials// Rusted Corten Steel. Options// Finishings// Lacquered Steel. Accessories// Black Glass Mirror

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

* * KR54-F, KR9854 & KR9954 Installation Instructions. Read All Warnings Before Starting Installation! Index:

Apply for further information to the manufacturer, if you ve got additional questions after studying this manual.

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

Gas Conversion Kits and Instructions

Automated Tiki Torch Installation Instructions

INSTRUCTIONS MANUAL CAST IRON STOVE

Aquastream. Thermo. Thermostatic integral power shower. Installation guide. Aquastream Thermo installation instructions Page 1

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

FERRULES & TOOLS Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

Stonefire Fire Pit Table. Installation Instructions for SF-32-K

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL

Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36

quick and easy installation guide

HD81 RIVER ROCK / STONE BURNER ASSEMBLY

INSTALLATION INSTRUCTIONS TOWNSEND

NFL Series Helmet and Football Peg HELMET PEG. The NFL Series Laser Pegs kit Football Peg has only one mating end. Affixing NFL Team Logo Stickers

Transcription:

Total solder points: 129 Difficulty level: beginner 1 2 3 4 5 advanced LIQUID LEVEL CONTROLLER K2639 Forgotten to turn off the tap, leaking washing machines,... Prevention is better than cure. So use this fluid detector. This multifunctional device is easy to use in a variety of applications. ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

Introduction & Specifications Did you forget to turn off the tap? Is the washing machine leaking? Will the aquarium level fall too low? Has the rain water tank overflowed? Do you have water in the cellar? Just a minor mishap, or a disaster! You can avoid all this by installing the liquid level controller in the right way and in the right place. Level indicator : three LED's are used to indicate LOW LEVEL, MEDIUM LEVEL and HIGH LEVEL. Level controller : the relay automatically switches a pump and/or valve on and off to keep the level between LOW and HIGH. Alarm : an alarm signal is available to indicate wet or dry. Some applications may demand a siren (e.g. KIT K2604), or perhaps a bell or a lamp may be more suitable. It is possible to replace the liquid sensors with other sensors, e.g. temperature or light dependent resistors (NTC/LDR) and thus use the device as a temperature/light controller. SPECIFICATIONS: Power supply: 12-14VAC or 16-18VDC / 100mA Relay output: 240V / 3A max. Dimensions: Controller PCB: 104 x 60mm (4.1" x 2.4") Sensor PCB: 104 x 25mm (4.1" x 1.0") Recommended transformer: ordernr. 207004 Recommended adapter: ordernr. PS1203 2

Assembly hints 1. Assembly (Skipping this can lead to troubles! ) Ok, so we have your attention. These hints will help you to make this project successful. Read them carefully. 1.1 Make sure you have the right tools: A good quality soldering iron (25-40W) with a small tip. Wipe it often on a wet sponge or cloth, to keep it clean; then apply solder to the tip, to give it a wet look. This is called thinning and will protect the tip, and enables you to make good connections. When solder rolls off the tip, it needs cleaning. Thin raisin-core solder. Do not use any flux or grease. A diagonal cutter to trim excess wires. To avoid injury when cutting excess leads, hold the lead so they cannot fly towards the eyes. Needle nose pliers, for bending leads, or to hold components in place. Small blade and Phillips screwdrivers. A basic range is fine. For some projects, a basic multi-meter is required, or might be handy 1.2 Assembly Hints : Make sure the skill level matches your experience, to avoid disappointments. Follow the instructions carefully. Read and understand the entire step before you perform each operation. Perform the assembly in the correct order as stated in this manual Position all parts on the PCB (Printed Circuit Board) as shown on the drawings. Values on the circuit diagram are subject to changes. Values in this assembly guide are correct* Use the check-boxes to mark your progress. Please read the included information on safety and customer service * Typographical inaccuracies excluded. Always look for possible last minute manual updates, indicated as NOTE on a separate leaflet. 0.000 3

Assembly hints 1.3 Soldering Hints : 1- Mount the component against the PCB surface and carefully solder the leads 2- Make sure the solder joints are cone-shaped and shiny 3- Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME! AXIAL COMPONENTS ARE TAPED IN THE CORRECT MOUNTING SEQUENCE! 4 You will find the colour code for the resistances and the LEDs in the HALG (general manual) and on our website: http://www.velleman.be/common/service.aspx

Construction 1. Jumpers J : 2x 2. Diodes. Check the polarity! D1 : 1N4148 D2 : 1N4148 D... CATHODE D3 : 1N4148 D4 : 1N4148 D5 : 1N4148 D6 : 1N4007 3. Resistors R... R1 : 1M (1-0 - 5 - B) R2 : 47K (4-7 - 3 - B) R3 : 47K (4-7 - 3 - B) R4 : 47K (4-7 - 3 - B) R5 : 47K (4-7 - 3 - B) R6 : 47K (4-7 - 3 - B) R7 : 47K (4-7 - 3 - B) R8 : 47K (4-7 - 3 - B) R9 : 47K (4-7 - 3 - B) R10 : 47K (4-7 - 3 - B) R11 : 47K (4-7 - 3 - B) R12 : 680 (6-8 - 1 - B) R13 : 680 (6-8 - 1 - B) R14 : 680 (6-8 - 1 - B) R15 : 680 (6-8 - 1 - B) R16 : 68K (6-8 - 3 - B) R17 : 68K (6-8 - 3 - B) R18 : 4K7 (4-7 - 2 - B) R19 : 4K7 (4-7 - 2 - B) R20 : 4K7 (4-7 - 2 - B) R21 : 12K (1-2 - 3 - B) R22 : 1M (1-0 - 5 - B) 4. Capacitors C1 : 100nF (104) C2 : 100nF (104) C3 : 100nF (104) C4 : 100nF (104) C5 : 100nF (104) C6 : 100nF (104) C7 : 100nF (104) C8 : 100nF (104) 5. IC socket, Watch the position of the IC1 : 14p 6. Transistor T1 : BC547B 7. LEDs. Watch the polarity! LD1 : 5mm red LD2 : 5mm yellow LD3 : 5mm green LD4 : 5mm red LD1 : High level LD2 : Medium level LD3 : Low level LD4 : Relay activated CATHODE COLOR= 2...5 LD. LD... 5

Construction 8. Capacitor 10. Electrolytic capacitor. Watch the polarity! 13. Relay C9 : 10µF / 25V C... C11 : 22nF 9. PCB pins Fit four terminal pins between marks S1 and S2. You may also use screw connectors. Fit 6 terminal pins for the relay output (NO, C, NS) and the power supply (AC IN). You may also use screw connectors. Fit 4 terminal pins to the holes A, B, C and D 11. Voltage regulator VR1 : UA7812 Check the orientation! 12. Electrolytic capacitor. Watch the polarity! C10 : 1000µF / 35V VR... C... RY1 : VR15M121C 12V / 15A 14. IC mounting IC1 : LM324 RY... Pay attention to the position of the notch! 1 PIN 1 6

Testing 15. Testing Inspect the completed board thoroughly before connecting a power supply. When applying a DC voltage (16 to 18V/100 ma) : The positive input should go to the pin nearest AC IN, the negative input to the second pin (Fig 1.0). - + NO C NC VR1 ACin ACin Fig 1.0 2x 7.5VAC 300mA NO C NC VR1 ACin ACin Fig 2.0 ADAPTER (16-18VDC/100mA) For connecting a transformer (12 to 14V/min 300 ma): The connection sequence isn t important (Fig 2.0). L 120-230 VAC N 7

Testing With power on, LD3 (LOW LEVEL) should illuminate, showing that everything works. Put a link across low-level sensor S2, and LD2 should illuminate. LD4 LD3 LD2 LD1 S1 Fig 3.0 S2 Add another link across high-level sensor S1, and LD1 and LD4 should both illuminate. Fig 3.1 LD4 LD3 LD2 LD1 S1 S2 Remove the link across input sensor S1, now LD2 should illuminate together with LD4 (relay on). Fig 3.2 LD4 LD3 LD2 LD1 S1 S2 Remove the link across input sensor S2, now only LD3 should illuminate. LD4 LD3 LD2 LD1 S1 Fig 3.3 S2 8

Applications 16. Applications For application as controller/indicator and alarm, 1 or 2 sensors must be connected. A sensor consists of 2 separated electric conductors : 2 metal strips on a PCB or a jack plug etc. There are 2 sensors on the sensor PCB : S1 (HIGH LEVEL) and S2 (LOW LEVEL). Cut a piece of your sensor PCB when the difference in height between S1 and S2 is too high for your application (Fig 4.0). Fig 4.0 On the contrary, if the levels are too close, lengthen S2 by soldering two un-insulated wires to the copper traces (Fig 5.0). Unisolated wire Solder Fig 5.0 9

Applications A dry sensor behaves like an electric isolator. When the sensor is wet the resistance drops to some Kilo-Ohms maximum. The electrical resistance of a sensor depends on the conductivity of the liquid, spacing between the electrodes, and the wet areas of the electrodes. The specific conductivity of some liquids is so high that this controller can t detect them. Sometimes the problem may be solved by increasing the surface of the electrodes. To avoid electrolysis or deposits on the sensor strips, the sensing voltage is alternating with a frequency around 1KHz. NEVER USE sensors in an INFLAMMABLE ENVIRONMENT: when the sensors get dry small sparks can occur which are able to ignite pockets of gas with a resultant explosion. In a chemical environment (acids...) metal electrodes can erode. It may be necessary to construct the electrodes of an inert metal e.g. inox. INDICATOR / CONTROLLER Connect both sensors. ATTENTION : Place sensor S1 higher than sensor S2 S1 S2 LIQUID LEVEL CONTROLLER S2 S1 S1 S2 10

Applications Working : With both sensors dry, LD3 illuminates (LOW LEVEL), fig 6.0 When sensor S2 is wet, LD2 illuminates (MEDIUM LEVEL), fig 6.1 When the liquid level rises and S1 also becomes wet, LD1 (HIGH LEVEL) and LD4 (relay on ) illuminate, fig 6.2 If the level then falls and only sensor S2 remains wet, LD2 and LD4 illuminate, fig 6.3 If the level keeps falling and sensor S2 also becomes dry, only LD3 illuminates, and the relay is switched off, fig 6.0 To Main PCB To Main PCB LD3 LD2 Fig 6.0 Fig 6.1 To Main PCB To Main PCB LD1 LD2 LD4 LD4 NC NO NC NO C Fig 6.2 Fig 6.3 C 11

Applications NOTE : the relay is switched on when the level reaches S1 (HIGH LEVEL) and is then switched off when the level falls under S2 (LOW LEVEL) ATTENTION : The relay contacts are rated at 3 Amps max. ALARM Link the pins of sensor S1 to the pins of sensor S2 as follows : 1) link the pin near C5 to the pin near C6 2) link the pin near C4 to the pin near C7 Connect pins adjacent to C4 and C5 to a sensor. When dry, LD3 illuminates (Fig 7.0). When wet, LD1 and LD4 will illuminate and the relay is energized (Fig 7.1). The NORMALLY OPEN contact gives a wet alarm signal. The alarm will keep going for as long as the detected condition is present. Multiple sensors may be connected in parallel. NC S1 S2 To Main PCB LD3 NC Fig 7.0 Fig 7.1 NO LD1 LD4 NC NO C RELAY C 12 RELAY

Applications ALARM WITH HOLD MEMORY I. Alarm when the sensor detects liquid : Mount liquid sensor S1 and connect a NC pushbutton with the connection pins of sensor S2. As soon as the sensor detects liquid, the relay receives power (LED LD4 starts burning) and remains powered, even when the sensor returns to a dry state. The alarm device is activated through the NO relay. The alarm cannot be switched of before the sensor has stopped detecting liquid. When this is the case, press the pushbutton to switch the alarm off. A next liquid detection will reactivate the alarm. II. Alarm when the sensor does not detect liquid Mount liquid sensor S2 and connect a NO pushbutton with the connection pins of sensor S1. Connect the alarm device in series With the NC relay. If the alarm should be active after mounting, press the pushbutton to switch it off. If the sensor does not detect liquid, even for the briefest of moments, the relay will switch and the alarm will become active. The alarm cannot be switched off until the sensor detects liquid again. Push the pushbutton briefly: the relay is powered and the alarm is switched off. 13

Schematic diagram 17. Schematic diagram. 14

PCB 18. PCB 15

VELLEMAN Components NV Legen Heirweg 33 9890 Gavere Belgium Europe www.velleman.be www.velleman-kit.com Modifications and typographical errors reserved Velleman Components nv. H2639IP - 2004 - ED1 5 410329 323547