Service Bulletin HHXDF5 Mechanical Ride-On Trowels LPG Hose Replacement

Similar documents
Water Trailer Series. WT5HR Hose Reel Kit Installation REQUIRED TOOLS PARTS WORK SAFELY! PREPARATION

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

REPLACEMENT PROCEDURE: ROTISSERIE ORIFICE: TOOLS REQUIRED TO INSTALL THIS KIT: ITEM DESCRIPTION: E C

Gas Go Anywhere /23/01

Advantage Plus TIM-3600 Series Reel

ASSEMBLY GUIDE. Customer Service: INCH² 3-BURNER & 545 INCH² 3-BURNER

CP V3 Air/Oil Separator WRX / STi. S0699 Install Instructions. Parts List

APPENDIX A LIGHT SOURCE

BILLY GOAT KV HOSE KIT (P/N ) PURPOSE: To allow for vacuuming in hard to reach places.

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

300 ft. 5/8 Hose wagon

INSTALLATION GUIDELINES

Colonial and Grand Colonial Fire Pit Tables. Installation Instructions for

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

For converting 72 PKN for use with (LP) propane gas.

Assembly/Installation/Use Instructions:

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

Stonefire Fire Pit Table. Installation Instructions for SF-32-K

Urea/Adblue Hose Reel

Blue Series Hot Melt Hose with RediFlext II Hanger System

TCWS54 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

t420 Barbecue Assembly Manual

Brooks Fire Pit Table. Installation Instructions for Brooks Fire Pit Table BRK-1224

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

INFRARED BURNER KIT INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR MVK-NQM PILOT KIT

CATALOG OF REPLACEMENT PARTS

Mazdaspeed6 Stage 1 Location 2 OCC Kit Install guide

Genesis. Side Burner Accessory Installation. Step 3. Step 1. Step 2. For use with Genesis Gas Barbecues Only

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

Safety. BBA Compliance Kit Multi-Pro 5800 Turf Sprayer Model No Installation Instructions

The Wave. Installation Instructions for WV-56 Table

Factory Style Bow Kit

Installation and User s Manual 12 x 10 MOTORIZED AWNING

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

Key Largo Fire Pit. Installation Instructions. 1 P a g e. NorthlineExpress.com. Toll-Free

Type N550 Packing Removal/Replacement

NS 200 Series Hose Reel January 2011

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

Professional Series Galley Range

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

PARTS BOOK CATALOG SIDE HD FLAIL HEADS TRACTOR MID-MOUNT

MOTORIZED FOLDING CAMPER WINCH

JARVIS. Model 70 Airsnip Air Powered Scissors

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TOWNSEND

TC36 SEE-THRU LODGEWOOD BURNER AND PANEL KIT INSTRUCTIONS

GoBidet Bidet Attachment

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

280 Propane Barbecue Assembly Manual

FORCE 10 MARINE BARBEQUES

Thermostatic Griddle Field Service Kit Instructions

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

Gas Conversion Kits and Instructions

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

INFRARED BURNER KIT INSTRUCTIONS

14' x 32' x 12' Round Top Round Style Shelter Assembly Instructions

Hose Reel Series L701/G701

Boardwalk Fire Pit Table

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

CHANGING YOUR LANDSCAPE SINCE 1945 OWNER S MANUAL. Tow Hitch Replacement Kit For Rough Cut Trailcutters. Starting Serial # L

kit contents installation instructions suzuki samurai silicone radiator hose kit kit ( suzuki samurai, 1.

Style # Laguna Propane Tank Cover Owner s Manual

TC42 TRANQUILITY BURNER KIT INSTRUCTIONS

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

DC 700 Series Hose Reel - September 2010

COOPER FREESTANDING TUB FAUCET INSTALLATION

PROPANE & HIGH ALTITUDE CONVERSION INSTRUCTIONS

HAND HELD BALL VALVE & DETENT STYLE BALL VALVES

DR LEAF & LAWN VACUUM

AUTO REWIND HOSE REEL WITH 50 FOOT HOSE. Model 46320

Installation Instructions

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

S420 Barbecue Assembly Manual

NATURAL GAS CONVERSION KIT

TC42 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

PARTS LIST COLT COLT HEPA

Instructional Booklet

Operating Instructions

Assembly TOOLS REQUIRED: 17mm and 14mm or equivalent wrenches.

Installation Guide. Single-Control Kitchen Sink Faucets

Tidland External Element Shaft

INSTRUCTIONS MANUAL CAST IRON STOVE

CONVERSION INSTRUCTIONS

BERYL Service Guide. Travel Adjust OTT Change

Shut off combine and remove key before installing the hopper extension. Make sure the combine is on a level surface. Engage parking brake.

Uptown Fire Pit Table

Model 205 Fireview Maintenance Kit

Darkly LabsR AIR-ASSIST. Installation Manual. English. Deutsch. Emblaser 2 Air-Assist Installation Manual 1.3

42" SNOW BLADE. Owner's Manual. Model No Safety Assembly Operation Maintenance Parts

HAND HELD BALL VALVE & DETENT STYLE BALL VALVES

General Purpose Shelter

Quick Connect Fitting Set (Optional) Can be ordered at

Mishimoto Direct Fit Coolant Expansion Tank All (EcoBoost install)

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Transcription:

Service Bulletin HHXDF5 Mechanical Ride-On Trowels LPG Hose Replacement Product Group: Date Issued: Service Bulletin No. Ride-On Trowels Bulletin Type X Mandatory 2/6/6 TR20622 Models/Series Affected: HHXDF5 S/N R020909 PH2003309 Information Only Recommended Change Details Replace original LPG hoses with UL listed hose assemblies. Parts Information Table. HHXDF5 LPG Hose Service Kit Item No. Part No. Description QTY. Remarks 32827-SK Service Kit, LPG Hose, HHXDF5 Includes Items 2-7 5 0 8 9 3 2 2 32826 Hose Assy, /4" ID LPG X 20.5", 2-/4 MP 3 32830 Hose Assy, /4" ID LPG X 2.5", 2X/4 MP 4 3283 Loctite, 567-6ML 4 5 32832 Fitting, Str. -4FJX-4FP 6 32833 Fitting, 90-4MJ X -4MBSPT 7 32834 Clamp, Stepless Ear - 20mm 4 6 8 32835 Fitting, 90 Brass /2" Barb X 3/8" MNPT 90 9 32836 Fitting, Str. Brass /2" Barb X 3/8" FNPT Figure. Kit, LPG Hose, HHXDF5 0 60072 Hose, Fuel Ø.50 Low Perm 35 PSI.34' 60072 Hose, Fuel Ø.50 Low Perm 35 PSI.46' HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/4/6 PAGE

WORK SAFELY! Only a qualified service technician with proper training should perform this installation. Follow all shop safety rules when performing this installation. PREPARATION. Make sure trowel is turned off and engine is cool. 2. Place the trowel in an area free of dirt and debris. REQUIRED TOOLS Ratchet Set Crimping Tool 0mm,3mm, 9/6", 3/4" Open-End Wrenches Bench Vise Flat Screwdriver LPG TANK SAFETY DANGER DO NOT smoke around or near the equipment. Fire or explosion could result from gas vapors. Accumulation of LP gas vapors may result in the development of an oxygen-deficient atmosphere which carries a risk of asphyxiation. NEVER enter a gas cloud area. This condition produces an oxygen-deficient atmosphere that could be fatal. CAUTION ALWAYS use protective gloves when handling LPG tank. LP gas will cause cold burns if it comes into contact with the skin. The eyes and body must be protected when handling all LP gas products. ALWAYS wear protective eye safety glasses and clothing. BATTERY SAFETY ALWAYS keep battery cables in good working condition. Repair or replace all worn cables. BATTERY DISCONNECTION. Remove left side guard to access battery. Disconnect negative cable (BLACK) from the negative terminal on the battery (Figure 2). Figure 2. Disconnect Battery Cable DANGER DO NOT expose the battery to open flames, sparks, cigarettes, etc. The battery contains combustible gases and liquids. If these gases and liquids come into contact with a flame or spark, an explosion could occur. ALWAYS disconnect the NEGATIVE battery terminal before performing service on the equipment. HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/6/6 PAGE 2

LPG TANK REMOVAL. CLOSE shutoff valve (Figure 3) on LPG tank. Push LPG tank backward and lift upward and remove tank. LIFT/PULL BACK RETAINING STRAPS SHUT-OFF VALVE SUPPORT CRADLE Figure 3. Close LPG Tank Shutoff Valve 2. Disconnect LPG gas line nozzle (Figure 4) from LPG tank fill port. SHUT-OFF VALVE Figure 5. LPG Tank Removal 4. Remove bolts securing LPG tank retaining straps to frame. 5. Remove LPG retaining straps (Figure 6). Set bolts and LPG retaining straps aside. NOTICE LATCH LOCKING PIN, TO REMOVE TANK PUSH BACKWARD AND LIFT UPWARD. In order to gain access to the safety lock off valve it is necessary to remove the LPG tank retaining straps. TANK GAS FILL PORT GAS LINE NOZZLE Figure 4. Disconnecting LPG Gas Line Nozzle 3. Release LPG tank retaining strap latches (Figure 5). Figure 6. LPG Tank Strap Removal HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/6/6 PAGE 3

REPLACING THE LPG S. Lift up the operator's seat (Figure 7). 4. Remove the six screws that secure the rear panel (Figure 9) to the frame. Figure 7. Rear Panel 2. Loosen the clamp that attaches the air filter intake hose to the air filter. 3. Remove air filter intake hose (Figure 8), and set aside. Figure 9. Rear Panel Removal 5. Remove rear panel and set aside. 6. Loosen the two worm clamps (Figure 0) that secure the hose connected between the regulator and carburetor. Discard hose and worm clamps. AIR FILTER INTAKE AIR FILTER CLAMP Figure 0. Loosen Hose Clamps 7. Appy Loctite 567 to the male threads (Figure ) on the 90 fitting. LOCTITE #567 90 FITTING P/N 32836 STRAIGHT FITTING P/N 32835 Figure 8. Remove Air Filter Intake Hose Figure. Applying Loctite 567 (90 Fitting) HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/6/6 PAGE 4

8. Insert female straight fitting (P/N 32835) into 90 male fitting (P/N 32836) 9. Attach one end of the new short hose (P/N 60072) to female straight fitting (Figure 2). Attach stepless clamp (P/N 32834) and crimp. 0. Attach one end of the new long hose (P/N 60072) to 90 male straight fitting (Figure 2). Attach stepless clamp (P/N 32834) and crimp. STRAIGHT FEMALE FITTING P/N 32835 STEPLESS CLAMPS P/N 32834 90 MALE FITTING P/N 32836 FUEL P/N 60072 Figure 2. Connect Hoses to Fittings. Attach stepless clamps (P/N 32834) to the free end of the short and long hoses (Figure 3). 2. Attach the free end of the long hose to the regulator port and attach the free end of the short hose to the carburetor intake port (Figure 3). Figure 4. Crimping Stepless Clamps 4. Remove propane tank adapter fitting from the lower hose (Figure 5), and set aside. PROPANE TANK ADAPTER FITTING LOWER Figure 5. Remove LPG Connection Port Fitting T 5. Remove the 90 hose fitting (Figure 6) at the base of the regulator, and discard. Figure 3. Conecting Hoses To Carburetor/Regulator 3. Crimp both stepless clamps (Figure 4) on each end of the long and short hoses. Figure 6. 90 Fitting Removal HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/6/6 PAGE 5

6. Remove straight fitting (Figure 7) at the base of the regulator, and discard. 8. Cut the zip ties on the safety lock-off valve (Figure 9). HORT Figure 7. Straight Fitting Removal 7. Using a 0mm socket or wrench, remove the HHC M6 screw and /4" flat washer that secures the safety lock-off valve (Figure 8) to the frame. Set screw and washer aside. Figure 9. Cut Zip Ties 9. Unplug the safety lock-off valve connector (Figure 20). /4 FLAT WASHER (REMOVE) HHC M6 SCREW (REMOVE) UPPER FRAME SAFETY LOCK-OFF VALVE LOWER Figure 20. Unpluging Safety Lock Connector 20. Remove the safety lock-off valve as an assembly (Figure 2). Figure 8. Safety Lock-Off Valve Bolt Removal HORT Figure 2. Safety Lock Off Valve Removal HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/6/6 PAGE 6

2. Place the safety lock-off valve in a vise (Figure 22), remove the upper and lower hoses, and discard. NOTICE To ensure seal on valve fittings remains unbroken, use caution when removing hoses from safety lock off valve. If seal on valve fittings is broken, the fittings will need to be resealed. 23. Connect the shorter hose (P/N 32830) to the upper section on the safety lock off valve and the longer hose (P/N 32826) to the bottom section. Tighten both hoses securely. HORT Figure 22. Old Hoses Removal 22. Apply Loctite 567 to the threads (safety lock end) on the new upper hose (P/N 32830) and new lower hose (P/N 32826). Reference Figure 23. P/N 32830 Figure 24. Attaching New Hoses 24. Apply Loctite 567 to the threads on the free end of the upper hose (P/N 32830). Reference Figure 25. HORT P/N 32830 LOCTITE #567 TO REGULATOR LOCTITE #567 TO SAFETY LOCK OFF VALVE (UPPER) P/N 32826 LOCTITE #567 TO SAFETY LOCK OFF VALVE (LOWER) Figure 23. Applying Loctite 567 (Safety Lock Off Valve Side) Figure 25. Applying Loctite 567 (Regulator/LPG Adapter Sides) 25. Insert female straight fitting (P/N 32832) onto short hose (P/N 32830) male straight fitting. Regulator side. Reference Figure 26. HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/6/6 PAGE 7

28. Apply Loctite 567 to the male threads (Figure 28) on the 90 male fitting (P/N 32833). FEMALE STR. FITTING 90 MALE STR. FITTING MALE STR. FITTING Figure 26. Straight Fitting Connection 26. Reinstall safety lock-off valve assembly (Figure 27) in its original location. Secure valve assembly to frame with mounting hardware that was removed earlier. Tighten securely. /4 FLAT WASHER (INSTALL) HHC M6 SCREW (INSTALL) UPPER REGULATOR PORT Figure 28. 90 Fitting Installation 29. Insert 90 male fitting (P/N 32833) into regulator port and tighten securely. Fitting should point straight down so that the hose will extend vertically from the bottom of the fitting when connected (Figure 29). 30. Connect hose (P/N 32830) with female straight fitting (P/N 32832) to 90 male fitting (P/N 32833) as shown in Figure 29, and tighten securely. SAFETY LOCK-OFF VALVE FRAME LOWER Figure 27. Safety Lock Off Valve Installation 27. Reconnect electrical connections, and use zip-ties to fasten harness securely. Figure 29. Connect Hose to Fitting 3. Apply Loctite 567 to the male threads (Figure 30) on the hose that connects to the propane tank adaptor fitting. HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/6/6 PAGE 8

34. Reinstall LPG tank and test for any leaks using soapy water. 35. Reconnect battery. 36. Start engine and check upper hoses for any leaks that go to the carburetor. 37. After making sure there are no leaks, reattach rear panel with six screws (Figure 33). PROPANE TANK ADAPTOR FITTING APPLY LOCTITE T Figure 30. Applying Loctite 567 32. Reinstall LPG connection port fitting (Figure 3) and tighten securely. ORT Figure 3. Reinstall LPG Connection Port Fitting 33. Reattach LPG tank straps and fasten securely (Figure 32). Figure 33. Reattach Rear Panel 38. Reattach air filter intake hose and tighten hose clamp securely (Figure 34). Figure 34. Reinstall Air Filter Intake Hose Figure 32. Reattach LPG Tank Straps HHXDF5 RIDE-ON TROWEL LPG S SERVICE BULLETIN TR20622 2/6/6 PAGE 9

Service Bulletin HHXDF5 Mechanical Ride-On Trowels LPG Hose Replacement HERE S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Corporate Office 890 Wilmington Ave. Carson, CA 90746 Contact : mq@multiquip.com Service Department Tel. (800) 42-244 Fax (30) 537-3927 800-42-244 30-537-3700 Technical Assistance 800-478-244 Fax: 30-943-2238 CANADA Multiquip 40 Industriel Boul. Laval, Quebec, Canada H7L 6V3 Contact : infocanda@multiquip.com Tel: (450) 625-2244 Tel: (877) 963-44 Fax: (450) 625-8664 MQ Parts Department 800-427-244 30-537-3700 Warranty Department 800-42-244 30-537-3700 Fax: 800-672-7877 Fax: 30-943-2249 UNITED KINGDOM Multiquip (UK) Limited Head Office Unit 2, Northpoint Industrial Estate, Globe Lane, Dukinfi eld, Cheshire SK6 4UJ Contact : sales@multiquip.co.uk Tel: 06 339 2223 Fax: 06 339 3226 COPYRIGHT 206, MULTIQUIP INC. Multiquip Inc and the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property of their respective owners and used with permission. The information and specifi cations included in this publication were in effect at the time of approval for printing. Illustrations, descriptions, references and technical data contained in this document are for guidance only and may not be considered as binding. Multiquip Inc. reserves the right to discontinue or change specifi cations, design or the information published in this publication at any time without notice and without incurring any obligations. Your Local Dealer is: