Reprocessing Instructions and Inspecton Criteria

Similar documents
Symmetry Surgica l QUAD-LOCK Sterilization Container System

INSTRUCTIONS FOR USE (IFU)

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

V. Mueller. Genesis Low Temperature Reusable Rigid Sterilization Container System Operator s Manual

PM-X IR SURGICAL POWER & ACCESSORIES

STERILE CONTAINER SYSTEMS

Quad-Lock Container System. sterilization solutions. Symmetry Surgical s Quad-Lock container. system now features NEW sterilization modalities

STERILE CONTAINER SYSTEMS

Instrument Care and Handling Guide

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

Quad-Lock Container System. sterilization solutions. Symmetry Surgical s Quad-Lock container. system is equipped with a patent-pending,

Bard. BI-DIRECTIONAL and KELLY-WICK TUNNELERS. Instructions For Use. PK Rev. 1 04/06

3. SS 4. SS 5. SS 6. SS

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

Sterilization Containers. Customized solutions for value-preserving instrument reprocessing

Big SHOT III Hybridization Oven

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

INSTRUCTIONS FOR USE (IFU)

Instructions for Use A-dec Quick-Disconnect Syringes

BR B Bike Rack Instructions

S E L E C T I O N. Abdominal Crunch. User manual

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System

SB3T. Roll-InBuddy + Tilt. Dignity + Ease + Comfort. Product features include:

BRJK11F2, BTJK11F2, BRJK07F2, BTJK07F2, kit

STERILIZATION and PREPARATION

FORM (Apr. 2006)

RUPHIS Blade Clamp. Instruction Manual

Application Tooling Specification

Phantom Retractor System Overview

REMOTE SWABBING AND MICROBIOLOGICAL SAMPLING TOOLS (PATENTED) & CLEANING VALIDATION COUPONS REMOTE SWABBING & MICROBIOLOGICAL SAMPLING TOOLS

Compass Chair E310, E320, E330, E340, & E350. Product Manual E310, E320, E330, E340, & E350

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles

Sterilising Department. Buyers Guide.

SECTION 1. Endoscope Transport and Protection. SECTION 2. Manual Cleaning Bedside. SECTION 3. Manual Cleaning Decontamination

User Guide. M9 / M11 Self -Contained Steam Sterilizer. For Models: English Español Français M9 (-033 / -034) M11 (-033 / -034) Style U

Sterile Processing Department Solutions CLEANING POWER IN YOUR HANDS INSTRUMENT CLEANING BRUSHES. One Integrated Approach to Healthcare.

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

READ ME FIRST! IMPORTANT WARNING! ENG. Roof top tent

Anchor Family Product Manual for the Rifton Anchors

Innovative New Products

LDR Brachytherapy Seed Sterilization and Sorting Tray

Read all instructions and warnings before using this fireplace. WARNING

PRODUCT MANUAL - M096

SERVICE MANUAL- M126

SEDONA. Sedona ShowerSpa Model #1041 Owner s Manual

MODEL # 1 MANUAL CAN OPENER

Installation and User s Manual 12 x 10 MOTORIZED AWNING

OWNER S MANUAL. IMPORTANT: This instruction manual contains important information necessary for the proper assembly and safe use of the appliance.

Preparation. BEDRUG, INC. n 635 Old Hickory Blvd, Old Hickory, TN n n bedrug.com

OW LEE CASUAL FIRESIDE Q&A

LONG STRAP SEAL LONG STRAP SEAL DESCRIPTION PRODUCT PART NO: STS 035

YCU 750 TU Unitized Curtain Wall System

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Instructions for use, installation, and connection. Gas Built in Hob

INSTALLATION INSTRUCTIONS for folding arm awnings

Operation Manual SUPER BEAST Multi-tool SC-11M-10

1. Product Name INSULTECH Thermal Blanket Design LT450SS. 2. Manufacturer. 3. Product Description THERMAL INSULATION

1 Pan - 6 Ways to Cook! Works in the Oven & On All Stovetops! electric gas ceramic induction. Broil Bake Sauté Fry Steam Braise

2100 Series Series Emergency Pressure Relief Vent and Manhole Cover. North America Only. Table of Contents. Introduction. Scope of the Manual

OW LEE CASUAL FIRESIDE Q&A

Nylon pull up seal Narrow 3mm strap for smaller apertures Available in 3 lengths 200mm, 300mm, 400mm

Content. Type SIL100 Ultra-pure silicone hose 4. Type SIL200 Fabric-reinforced silicone hose 6. Type SIL300 Wire-reinforced silicone hose 8

31 Series. Serie 31 Série 31. Two Handle Kitchen Faucet Grifo Con Dos Manijas Para Cocina Robinet De Cuisine À Avec Deux Poignées COMPANY

Manufactured in New Zealand Metal Fab Industries Ltd PO Box Greenmount Auckland

CUTTING EDGE ILLUMINATION

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Safety instructions and warnings Package contents and parts Tool requirements Product features... 4

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles. Directions for Use

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

PLEASE READ BEFORE USE AND SAVE THESE INSTRUCTIONS

Levels & Measuring Tools

Professional Mandoline Manual. Model: 90797

DECONTAMINATION TENTS, SHOWERS, BASINS

Rhino-Rack FOXWING Awning by OZTENT

/ Tool and Equipment Safety Tether System (T.E.S.T.S)

Tools. For safety and easy faucet replacement, San-Ei recommends the use of the following helpful tools:

Laboratory Safety. A practical approach.

Safety instructions and warnings Package contents and parts Tool requirements Product features... 5

EMERGENCY BED SYSTEM

Manual Awning. Assembly Instructions. Product No Toll-free:

GV Standard Skyhatch Manual

INSTALLATION INSTRUCTIONS FOR BALCO, INC. FLOOR MATS FM2R-(A, C, D) W/O FRAME 4V

DO NOT USE WITH CROSSBAR SPREAD LESS THAN 24.

BOTTLE CAPS & CONNECTION SYSTEMS

Kajak Sediment Sampler Model Manual. KC Denmark. Research Equipment Limnology Oceanography Hydrobiology

Louvre Specifications

BOTTLE CAPS & CONNECTION SYSTEMS

Oletto Single Handle Commercial Style Kitchen Faucet

Model 205 Fireview Maintenance Kit

Clay Adaptors & Insert Stove Kits

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

FILTERED FAN PACKAGES

Tube and Valve Brushes

Operating Instructions

FagronLab FG. Semi-automatic capsule filling machine. User Manual

Owner/Operator Manual

AND EFFICIENCY. Typical 18 L (3 trays*) round chamber. A lot of space is wasted. 15 L (5 trays*) rectangular chamber utilizing the maximum volume.

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

Transcription:

Reprocessing Instructions and Inspecton Criteria DEVICE DESCRIPTION: The SteriTite universal container is a rigid, reusable, sealed medical sterilization packaging system validated for steam and low temperature sterilization systems. INTENDED USE: The SteriTite container system is intended to be used for the sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific reprocessing instructions as well as recommendations from your medical device manufacturer for material compatibility and requirements for extended sterilization cycles. Refer to the SteriTite Instructions for Use and the ANSI/AAMI ST79: 2006/A1:2008* Comprehensive Guide to Steam Sterilization and Sterility Assurance in Health Care Facilities for sterilization guidelines. Review the sterilizer manufacturer s operator s manual for additional detail for specific sterilizaton systems. REPROCESSING INSTRUCTIONS AND INSPECTION CRITERIA: 1. Clean after each use. Disassemble all container components. Clean manually using a soft, lint free cloth or process in an automated washer. If an automated washer is used, secure parts to avoid excess movement during processing. Make sure container latches are folded inward and handles are tucked within the racks and not protruding. The filter retention plate should be removed and placed in a basket for the cleaning process. 2. Always use a ph neutral detergent, recommended for use on aluminum. Multi-enzymatic cleaners may be used if they are ph neutral. Caution! Do not use abrasive cleaners, alkaline or acidic detergents, metal brushes or abrasive pads. 3. Rinse all components to prevent detergent residue. Dry thoroughly. 4. Do a visual inspection of all parts. Check that gaskets are properly secured and free of wear or damage. Latches should function properly. Case and lid should be free of dents, which may interfere with the seal. Be sure filter retention plate or valve plate fits securely. 5. Verify the integrity of gaskets and other component parts. 6. Remove the filter retention plate(s) by turning the handle of the locking mechanism clockwise. Adjust filter retention plate by bending down along the edge to modify the tension. 7. Replace the disposable filter after each use. 8. Secure the filter by turning handle counter clockwise. 9. Load the container with DRY surgical instruments. 10. Place chemical indicators or integrators on each level of surgical instrument tray. For SteriTite sealed containers place chemical indicators, integrators or biological indicators in corners of the basket or tray within the sealed container. 11. Secure the container by latching the lid to the base. The top of the latch fits over the ridge in the lid of the container. Push bottom section of the latch over the lock hold (clip). Thread a disposable tamper evident seal through the latching mechanism. 12. Place the proper load cards with complete information in the label holder on the right side of container latches. 13. If the containers are sterilized in an outside contract facility, they should be doubled wrapped in double plastic bags during transport. 14. Check with your sterilizer manufacturer for additional information on reprocessing sterilization containers in their sterilizer. Recommendations: Always use a ph neutral detergent for cleaning anodized aluminum sterilization containers and trays. Case Medical highly recommends its validated ph neutral Case Solutions and SuperNova instrument cleaners for decontamination of the SteriTite container system and other sealed container systems. Warning: Use of a caustic cleaner will damage the anodized surface of aluminum devices and will cause corrosion. This can void the company s warranty on its container system. Any questions about preparation and assembly should be directed to: Case Medical, Inc at 19 Empire Blvd, South Hackensack NJ 07606 Phone: 1-(888)-227-CASE or (201)-313-1999. Fax: 201-373-9090 To access our website, visit www.casemed.com * AAMI Standards order code: ST79: 2006, ST77: 2006 Association for the Advancement of Medical Instrumentation 3330 Washington Blvd. Arlington, VA 22201-4598 www.aami.org/publications/pubs.standards.html European Representative: Medical Products International Europe, B. V. Howard Klevens, Managing Director Schutweg 13 a 5145 NP Waalwijk, The Netherlands Telephone: 31 (0) 416-566081 Fax: 31 (0) 416-566087 Page 1.0/ Revision. M

for Steam Sterilization using disposable filter DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite container system is intended to be used for the sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific processing instructions as well as recommendations from your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. The load may be distributed in layers using MediTray baskets or trays. When stacking trays, leave 1 of clearance in container. Case Medical validated maximum load of 35lbs including container and contents. AAMI recommends a maximum of 25lbs total weight based on ergonomics. For SteriTite models and maximum load of contents please refer to the table below: MODEL# DESCRIPTION MA LOAD SC05W Wide Size 5 H - Solid Bottom 22 lbs SC08F SC06F SC04F SC08Q SC06Q SC04Q Full Size 8 H - Solid Bottom Full Size 6 H - Solid Bottom Full Size 4 H - Solid Bottom 3/4Size 8 H - Solid Bottom 3/4 Size 6 H - Solid Bottom 3/4 Size 4 H - Solid Bottom 22 lbs 12 lbs MODEL# DESCRIPTION MA LOAD SC05WG Wide Size 5 H - Perforated Bottom 22 lbs SC08FG SC06FG SC04FG SC08QG SC06QG SC04QG Full Size 8 H - Perforated Bottom 22 lbs Full Size 6 H - Perforated Bottom Full Size 4 H - Perforated Bottom 3/4Size 8 H - Perforated Bottom 3/4 Size 6 H - Perforated Bottom 12 lbs 3/4 Size 4 H - Perforated Bottom SC08H 1/2 Size 8 H - Solid Bottom SC08HG 1/2 Size 8 H - Perforated Bottom SC06H 1/2 Size 6 H - Solid Bottom SC06HG 1/2 Size 6 H - Perforated Bottom SC04H 1/2 Size 4 H - Solid Bottom SC04HG 1/2 Size 4 H - Perforated Bottom SC03M Mini Size 3 H - Solid Bottom 2. SC03MG Mini Size 3 H - Perforated Bottom 2. SC03Q 3/4 Mini Size 3 H - Solid Bottom SC03QG 3/4 Mini Size 3 H -Perforated Bottom Prevacuum steam sterilization: Use vented or solid base container for pre-vacuum steam. Apply paper or polypropylene disposable filter after each use. Use MediTray inserts in the container to secure instrumentation. Recommended for sterilization of medical devices, including blades, and metal lumens of 2mm minimum diameter up to 435mm in length and porous lumens 3mm minimum diameter up to 400mm in length. Recommended exposure time: 4 minutes at 270 F. Minimum recommended dry time is 20 minutes. Pre-vacuum steam flash Sterilization: Use vented or solid base container for pre-vacuum steam flash sterilization Flash sterilization is for immediate use only. Moisture may occur in flash cycles. Caution: Use a glove or towel when transporting hot items from the autoclave. Recommended exposure time: 4 minutes at 270 F (132 C) with 0-1min dry time. User may add additional dry time for a drier outcome. Use paper disposable filters: Disposable paper filter # SCF01 (7.5 diameter) and SCFM01 (10 4 ) are disposable medical device supplied nonsterile. Note: The user should contact their device manufacturer for appropriate (extended) sterilization cycle conditions. (ANSI/AAMI ST 79:2006 Comprehensive guide to steam sterilization and sterility assurance in health care facilities. Gravity displacement steam: Use only perforated base containers for gravity displacement steam. Use MediTray basic trays in container. Select the appropriate exposure time based on load and size of container. Validation testing demonstrated kill in 15 to 25 minutes. Recommended minimum exposure time: 30 minutes at 250 F. Minimum recommended dry time 30 minutes. Use of sealed containers may require additional exposure time in gravity displacement steam. Stackability of SteriTite Containers in steam sterilization: Up to three (3) containers can be stacked and processed in the autoclave. WARNING: Prepare complex instruments according to the instrument maker s instructions. Use of nonabsorbent tray liners can cause condensate to pool. Do not use peel pouches within sealed containers, as they cannot be placed on their side for sterilization. Note: To reduce condensate formation, crack the autoclave door for 10 to 15 minutes. EVENT RELATED STERILITY MAINTENENCE DATA: SteriTite containers are event related. Maintains sterility during transport and multiple handling events provided that the integrity of the seal is not broken. The associated tests consisted of testing samples after 30 to 90 days (real time) with handling events at a health care facility. SteriTite container for pre-vacuum flash was tested after a 24 hr period. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated in independent laboratories under fractional and half cycle conditions. Page 2.0/ Revision. M

for Flash Sterilization using FlashTite valve plate(s) DEVICE DESCRIPTION: The FlashTite valve plate(s) are attachments to the SteriTite rigid reusable sealed container for pre-vacuum flash and gravity displacement flash steam sterilization cycles. INTENDED USE: The SteriTite sealed container with FlashTite valve plate(s) is intended to be used for sterilization of one instrument or instrument set in flash sterilization. NOTE: Flashed items are for immediate use only, per AAMI guidance. Product was tested for sterility maintenance for 24 hours.. The FlashTite valve is recommended for one (1) year of use. Refer to expiration date on the plate for reference date to replace. Use MediTray basic trays for flash sterilization cycles. LOAD: The contents must be placed within an instrument basket or tray. FlashTite systems for gravity displacement steam flash sterilization require a load restricting basket designed to clear the FlashTite valves placed on the lid and on the base. For FlashTite models and basket insert. Please refer to the table below: FlashTite models for gravity displacement steam MODEL# DESCRIPTION BASKET SC08FGV Full Size 8 H - Perforated Bottom BSKF35LH SC06FGV SC08QGV Full Size 6 H - Perforated Bottom 3/4Size 8 H - Perforated Bottom SC06QGV 3/4 Size 6 H - Perforated Bottom SC08HGV 1/2 Size 8 H - Perforated Bottom SC06HGV 1/2 Size 6 H - Perforated Bottom BSKF15LH BSKQ35LH BSKQ15LH BSKH35LH BSKH15LH FlashTite models for pre-vacuum steam Either perforated bottom or solid bottom SteriTite containers may be used with FlashTite valve plate in pre-vacuum steam flash sterilization. Use MediTray basic trays for flash sterilization cycles. The SteriTite solid bottom containers including 4 high models may be used for flash sterilization with FlashTite valve plate(s) in lid. Pre-vacuum Flash Sterilization: Use either vented or solid base container with the same number of FlashTite valve plate(s) as the number of vents. Recommended parameters are 3 minutes exposure for non-porous items at 270 F (132 C) and 4 minutes exposure for porous items, lumens and mixed loads at 270 F (132 C). Recommended dry time for SteriTite container with FlashTite valve plate(s): 0-3 minutes dry time in the autoclave for items processed in flash sterilization depending on the degree of dryness required Gravity Displacement Flash Sterilization: Use only perforated bottom container. Attach FlashTite valve plate(s) over all vents. Recommended parameters are a minimum of 5 minutes exposure for non-porous items at 270 F (132 C) and minimum of 10 minutes exposure for porous items, lumens and mixed loads at 270 F (132 C). Recommended dry time: 0-3 minutes dry time in the autoclave for items processed in flash sterilization depending on the degree of dryness required. Note: Do not use the FlashTite valve with SteriTite perforated bottom models SC04HG, SC04QG and SC04FG, because of height restrictions within these containers. Do not use solid bottom SteriTite container with FlashTite valve in gravity displacement flash sterilization. Note: The evaluation of the container/sterilizer combination is especially important in gravity displacement steam sterilization because of the relative inefficiency of air removal in this sterilization process The user must review the data upon which the container manufacturer bases the recommended cycle time and must verify those results in the hospital s sterilizer. ANSI/AAMI ST79: 2006/A1:2008 Caution: When abbreviated dry time is implemented, moisture is present. Use a glove or towel when transporting hot items from the autoclave. Do not mix the FlashTite valve plate(s) with the filter retention plate(s) and disposable filter(s). Do not use the FlashTite valve plate(s) for EO or gas plasma (STERRAD) sterilization. Reprocessing Instructions: After use, disassemble and decontaminate the FlashTite valve plate with a multi-enzymatic and ph neutral detergent as you would any SteriTite component part. Thoroughly rinse and dry. Case Medical recommends that: A chemical indicator or integrator should be placed in every container for processing. Within the sealed container, place indicator in opposing corners. Case Medical recommends use of the 3M rapid read out biological indicator for verification. Note: The copper module within the FlashTite valve mechanism will darken over time. This color change will not effect the safety and effectiveness of the device. Refer to the sterilizer manufacturer s Instructions for Use for specific information as to the limitations of instrumentation, specifications and material compatibility. Complex instruments should be prepared and sterilized according to the instrument manufacturer s instructions. Contact the manufacturer of your endoscope or lumened devices when flashing. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated in independent laboratories under fractional and half cycle conditions. Page 3.0/ Revision. M

for EO Sterilization using disposable filter DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite container system is intended to be used for the sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific processing instructions as well as recommendations from your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. Load may be distributed in layers using MediTray basic trays. Leave 1 of clearance in container. AAMI recommends a maximum of 25lbs total weight. However Case Medical validated with maximum load. For SteriTite models and maximum load of contents please refer to the table below: MODEL# DESCRIPTION MA LOAD SC05W Wide Size 5 H - Solid Bottom 22 lbs SC08F SC06F SC04F SC08Q SC06Q SC04Q Full Size 8 H - Solid Bottom Full Size 6 H - Solid Bottom Full Size 4 H - Solid Bottom 3/4Size 8 H - Solid Bottom 3/4 Size 6 H - Solid Bottom 3/4 Size 4 H - Solid Bottom 22 lbs 12 lbs MODEL# DESCRIPTION MA LOAD SC05WG Wide Size 5 H - Perforated Bottom 22 lbs SC08FG SC06FG SC04FG SC08QG SC06QG SC04QG Full Size 8 H - Perforated Bottom 22 lbs Full Size 6 H - Perforated Bottom Full Size 4 H - Perforated Bottom 3/4Size 8 H - Perforated Bottom 3/4 Size 6 H - Perforated Bottom 12 lbs 3/4 Size 4 H - Perforated Bottom SC08H 1/2 Size 8 H - Solid Bottom SC08HG 1/2 Size 8 H - Perforated Bottom SC06H 1/2 Size 6 H - Solid Bottom SC06HG 1/2 Size 6 H - Perforated Bottom SC04H 1/2 Size 4 H - Solid Bottom SC04HG 1/2 Size 4 H - Perforated Bottom SC03M Mini Size 3 H - Solid Bottom 2. SC03MG Mini Size 3 H - Perforated Bottom 2. SC03Q 3/4 Mini Size 3 H - Solid Bottom SC03QG 3/4 Mini Size 3 H -Perforated Bottom EO Sterilization: SteriTite containers may be used in EO sterilization for sterilization of blades and lumens. Solid bottom containers may be used in EO pre-vacuum sterilizers. Residual analysis shows that EO and EC limits were found to be well below maximum limits after 12 hours post aeration at room temperature. Recommended exposure time in: 600 mg/liter EO gas mixture (90% CO2 / 10% EO) - 2 hours. 230 mg/liter EO gas mixture (91.5% CO2 / 8.5% EO) - 3 hours. Polymeric and porous materials may require extended EO exposure time. Items with lumens should be throughly dried for EO sterilization. In EO sterilization, metal lumened devices of 2.2mm diameter or larger and length up to 457 mm and porous lumened devices of 3mm diameter or larger and length up to 400 mm may be processed. Contact your medical device manufacturer for specific processing information. Up to three (3) containers can be stacked and processed in the EO sterilizer at one time. Do not use MediView plastic and hybrid cases in EO sterilization. EVENT RELATED STERILITY MAINTENENCE DATA: SteriTite containers are event related. Maintains sterility during transport and multiple handling events provided that the integrity of the seal is not broken. The associated tests consisted of testing samples after 90 days (real time) handling events at a health care facility. The perforated SteriTite container with MediTray product was tested in an event related study with daily handling events over a 30 to 90 day period. WARNING: Prepare complex instruments according to the instrument maker s instructions. Use of nonabsorbent tray liners can cause condensate to pool. Do not use peel pouches within sealed containers, as they cannot be placed on their side for sterilization. Stackability of SteriTite Containers in EO sterilization: Up to three (3) SteriTite containers can be stacked and processed in the sterilizer. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated in independent laboratories under fractional and half cycle conditions. Page 4.0/ Revision. M

for STERRAD Sterilization using dispoable PolyPro filter DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite container system is intended for use in STERRAD 100, 100S, 200 and STERRAD N sterilizers for the sterilization of reusable surgical instruments (blades and lumens) and for medical devices in health care facilities. MediTray products may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific processing instructions and to your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. Leave 1 of clearance in container. For STERRAD 100,100S, 200 and STERRAD N use only perforated base SteriTite containers with polypropylene filter. Validation testing was performed with maximum STU load of 22lbs (10kg) for blades and lumens For SteriTite models and maximum load. Please refer to the table below: STERRAD 100, 100S & 200: STERRAD N: MODEL# DESCRIPTION MA LOAD MODEL# DESCRIPTION MA LOAD SC08FG Full Size 8 H - Perforated Bottom 30.07 lbs SC04FG Full Size 4 H - Perforated Bottom 20.13 lbs SC06FG Full Size 6 H - Perforated Bottom 24.27 lbs SC04QG 3/4 Size 4 H - Perforated Bottom 15.70 lbs SC04FG Full Size 4 H - Perforated Bottom 20.13 lbs SC04HG 1/2 Size 4 H - Perforated Bottom 9.90 lbs SC08QG 3/4Size 8 H - Perforated Bottom 23.70 lbs SC03QG Mini Size 3 H - Perforated Bottom 8.8 SC06QG 3/4 Size 6 H - Perforated Bottom 22.40 lbs SC03MG 3/4 Mini Size 3 H - Perforated Bottom 5.63 lbs SC04QG 3/4 Size 4 H - Perforated Bottom 15.70 lbs Note: For STERRAD 100, 100S, & 200 all models of SteriTite perforated SC08HG 1/2 Size 8 H - Perforated Bottom 15.92 lbs bottom sealed containers may be used except for the SC05WG, which SC06HG 1/2 Size 6 H - Perforated Bottom 13. does not fit the STERRAD chamber. For STERRAD N Sterilization only the 3 high and 4 high containers SC04HG 1/2 Size 4 H - Perforated Bottom 9.9 lbs can be used due to STERRAD N chamber size. SC03QG Mini Size 3 H - Perforated Bottom 8.8 Part number with suffix G signifies perforated bottom container. Use SC03MG 3/4 Mini Size 3 H - Perforated Bottom 5.63 lbs with non-woven Polypro filter for STERRAD Sterilization. Use nonwoven polypropylene disposable filters: PolyPro filter # SCF02 (7.5 diameter) and SCFM02 (10 4 ) a disposable medical device supplied nonsterile.. -In STERRAD 100, 100S & 200 process only stainless steel lumened instruments of 3mm diameter or larger and a length up to 400 mm. -In STERRAD N standard cycle, process stainless steel lumened instruments of 2mm diameter or larger and up to 400 mm in length. -In STERRAD N advanced cycle, process stainless steel lumened instruments of 1mm diameter or larger and up to 500 mm in length and porous lumens (flexible endoscope) of 1mm diameter or larger and up to 850 mm in length. Adequate sterilant penetration and barrier properties were demonstrated using the SteriTite rigid reusable container system and MediTray products in the STERRAD 100,100S, 200 & STERRAD N Sterilization Systems under half cycle and fractional studies. STERRAD Systems have pre programmed cycles for each unit. Cycle time: The sterilizer manufacturer determines STERRAD Sterilization cycle time. For example, the recommended cycle time for STERRAD 200 is 6.5 minute injection, 2 minute diffusion, and 2 minute plasma Recommended cycle time for STERRAD N Standard is 3 minute injection, 0.5 minute diffusion, and 4 minute plasma. Recommended cycle time for STERRAD N Advanced is 7 minute transfer, 0.5 minute diffusion, and 4 minute plasma. Caution: In STERRAD Sterilization do not use materials made of cellulose (paper filters and cotton) with SteriTite containers. Caution: In STERRAD Sterilization use only compatible materials and instruments as stated in the STERRAD Operating Manual. Consult with your instrument manufacturer as to the compatibility of various materials in STERRAD Sterilization. Refer to ASP s STERRAD System Operating Manual, instructions for use and labeling. Internal Stacking: MediTray baskets and trays may be stacked within the SteriTite container system as follows: In STERRAD N up to two (2) instrument baskets or trays may be stacked within the SteriTite container. In the STERRAD 200 up to four (4) instrument baskets or trays may be stacked. In STERRAD 200 & N, the following MediTray baskets are not intended to be stacked : BSKF04, BSKF06, BSKH04, BSKQ04, and BSKQ06. In addition, MediTray insert boxes are not intended to be stacked. Case Medical recommends that its containers be placed on the sterilizer shelf. External stacking was not tested. For STERRAD 100, 100S & 200: All models of SteriTite containers, can be placed on each of the two shelves within the STERRAD 200. However, only one shelf can be used to accommodate an 8" high perforated base SteriTite container, because of height restrictions within the sterilizer s chamber. For STERRAD N only 3" and 4" high containers will fit in the sterilizer chamber. Only one shelf is available for placement of SteriTite containers within the STERRAD N. MediTray Products including MediTray inserts, instrument baskets, stacking trays, BackBone silicone brackets, stainless and aluminum brackets, posts and partitions may be used in STERRAD Sterilization. Caution: Do not use nylon coated brackets or silicone mat. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated under fractional and half cycle conditions. Page 5.0/ Revision. M

for Ozone Sterilization with disposable filter DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite container system is intended for use in 125L Ozone Sterilizer for sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific processing instructions as well as recommendations from your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. Load may be distributed in layers using MediTray baskets and trays. Leave 1 of clearance in container. AAMI recommends a maximum of 25lbs total weight. However Case Medical validated with maximum load. For SteriTite models and maximum load of contents please refer to the table below: MODEL# DESCRIPTION MA LOAD SC05W Wide Size 5 H - Solid Bottom 22 lbs SC08F SC06F SC04F SC08Q SC06Q SC04Q Full Size 8 H - Solid Bottom Full Size 6 H - Solid Bottom Full Size 4 H - Solid Bottom 3/4Size 8 H - Solid Bottom 3/4 Size 6 H - Solid Bottom 3/4 Size 4 H - Solid Bottom 22 lbs 12 lbs MODEL# DESCRIPTION MA LOAD SC05WG Wide Size 5 H - Perforated Bottom 22 lbs SC08FG SC06FG SC04FG SC08QG SC06QG SC04QG Full Size 8 H - Perforated Bottom 22 lbs Full Size 6 H - Perforated Bottom Full Size 4 H - Perforated Bottom 3/4Size 8 H - Perforated Bottom 3/4 Size 6 H - Perforated Bottom 12 lbs 3/4 Size 4 H - Perforated Bottom SC08H 1/2 Size 8 H - Solid Bottom SC08HG 1/2 Size 8 H - Perforated Bottom SC06H 1/2 Size 6 H - Solid Bottom SC06HG 1/2 Size 6 H - Perforated Bottom SC04H 1/2 Size 4 H - Solid Bottom SC04HG 1/2 Size 4 H - Perforated Bottom SC03Q Mini Size 3 H - Solid Bottom SC03QG Mini Size 3 H - Perforated Bottom SC03M 3/4 Mini Size 3 H -Solid Bottom 2. SC03MG 3/4 Mini Size 3 H -Perforated Bottom 2. PARAMETER FOR USE: 125L Ozone Sterilization: Use vented or solid base container for 125L Ozone sterilization. Use MediTray products in the container to secure instrumentation. Recommended for sterilization of medical devices, including blades, and stainless steel lumened instruments of 3mm diameter or larger and a length up to 470 mm. Do not use silicone mats as it was not designed for this purpose. Slight discoloration with our device may occur in 125L Ozone sterilization. Cycle time: The sterilizer manufacturer determines 125L Ozone Sterilization cycle time. For example, the recommended exposure time is 15 minutes. Cycle temperature: between 30.8 C and 36 C (87.4 F and 96.8 F). EVENT RELATED STERILITY MAINTENENCE DATA: SteriTite containers are event related and maintain sterility during transport and multiple handling events provided that the integrity of the seal is not broken. The associated sterility maintenance test consisted of challenging the perforated bottom SteriTite container with MediTray product for 30 days real time with multiple handling events. Note: The user should contact their device manufacturer for appropriate sterilization cycle conditions. (ANSI/AAMI ST 79:2006 Comprehensive guide to steam sterilization and sterility assurance in health care facilities). Use paper or nonwoven disposable filters: Disposable paper filter # SCF01, SCF02 (7.5 diameter) SCFM01 and SCFM02 (10 4 ) are disposable medical device supplied nonsterile. Stackability of SteriTite Containers in 125L Ozone Sterilization: External Stacking: Up to three (3) containers can be stacked and processed in the 125L Ozone Sterilizer. Internal Stacking: Testing was done with up to three (3) stacked trays or baskets inside the containers. Adequate sterilant penetration and barrier properties were demonstrated using the SteriTite rigid reusable container system and MediTray products in the 125L Ozone Sterilization System under half cycle and fractional studies. Caution: In 125L Ozone process only lumened instruments of 3mm or larger and a length up to 470 mm. Caution: In 125L Ozone Sterilization use only compatible materials and instruments as stated in the Ozone 125L Operating Manual. Specifically: Consult with your instrument manufacturer as to the compatibility of various materials in Ozone 125L Sterilization. Refer to TSO3 125L Ozone System Operating Manual instructions for use and labeling. MediTray Products including MediTray inserts, instrument baskets, stacking trays, BackBone silicone brackets, stainless and aluminum brackets, posts and partitions may be used in 125L Ozone Sterilization. Caution: Do not use nylon coated brackets or silicone mat in 125L. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated under fractional and half cycle conditions. Page 6./ Revision. M

for Amsco V-PRO1 Low Temperature Sterilization System DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite universal container system with MediTray products is a reusable sterilization container system used to enclose other medical devices, which are to be sterilized, transported and stored by a health care provider. The SteriTite container system is intended for use in Steris Amsco V-PRO 1 low temperature Sterilization System Lumen Cycle. SteriTite Sealed Container system is recommended for surface and stainless steel lumens (process up to 20 stainless steel lumened instruments of 3mm diameter or larger and a length up to 400 mm or shorter).please refer to the recommendations of the sterilizer manufacturer for specific processing instructions and to your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. Leave 1 of clearance in container. container For example a 3 high basket may be placed within a 4 high container. SteriTite models and maximum load of contents please refer to the table below: For Amsco V-PRO 1 H2O2 Sterilization System V-PRO 1 w/ MODEL# DESCRIPTION polypropylene disposable filter MA LOAD SC05WG Wide Size 5 H - Perforated Bottom x 19.97 lbs SC08FG Full Size 8 H - Perforated Bottom x 19.97 lbs SC06FG Full Size 4 H - Perforated Bottom 19.97lbs SC04FG Full Size 4 H - Perforated Bottom 19.97lbs DESCRIPTION PART NUMBER AMSCO V-PRO 1 BASKETS TRAYS ENDO TRAYS MediTray Products Compatibility Table BSKH01, BSKH02, BSKH03, BSKH04, BSKQ01, BSKQ02, BSKQ03, BSKQ04, BSKF01, BSKF02, BSKF03, BSKF04 ST01, ST02, STQ1, STQ2, MT01, HT01, QT01 ENDOH1, ENDOQ1, ENDOF1, ENDOF1T456, ENDOQ2, ENDOF2 SC08QG 3/4 Size 8 H - Perforated Bottom x 19.97 lbs SC06QG 3/4 Size 6 H - Perforated Bottom x 19.97lbs SC04QG 3/4 Size 4 H - Perforated Bottom 15.7 lbs SC08HG 1/2 Size 8 H - Perforated Bottom x 15.92 lbs SC06HG 1/2 Size 6 H - Perforated Bottom x 13.16lbs SC04HG 1/2 Size 4 H - Perforated Bottom 9.97lbs SC03QG 3/4 MiniSize 3 H -PerforatedBottom 8.85lbs SC03MG Mini Size 3 H - Perforated Bottom 5.63 lbs INSERT BOES METAL BRACKETS METAL PARTITIONS METAL POSTS SILICONE BRACKETS INSTRUMENT STRINGERS EC00, EC01, EC02, EC07, EC08, APC01, APC02, APC03, APC04 B01, B02, B03, B04, B05, B06, B07, B08, BM01, BM03, BM04 BM05, BM08, P01, P02, P03, P04, P05, P06, P07, P08 POST01, POST015, POST02, POST03 BMS01, BMS02, BMS03, BMS04, BMS05, BMS06, BMS07, BMS08, BMS10, BES170, BES171, BES001, BES002 INST06, INST09, INST012 Note: All containers for Steris Amsco V-PRO 1 low temperature Sterilization System are perforated bottom containers, which must be used with the single-use non-woven Polypro filter. Use nonwoven polypropylene disposable filters: Disposable nonwoven Filter # SCF02 (7.5 diameter) and SCFM02 (10 4 ) are a single use disposable medical device supplied nonsterile. In Steris Amsco V-PRO 1 low temperature Sterilization System, validation testing was performed with blades and lumens. Only stainless steel lumened instruments of 3mm diameter or larger and a length up to 400 mm should be processed. Adequate sterilant penetration and barrier properties were demonstrated using the SteriTite rigid reusable container system and MediTray products in the Steris Amsco V-PRO 1 low temperature Sterilization System under half cycle and fractional studies. Stackability of SteriTite Containers in Steris Amsco V-PRO 1: MediTray baskets and trays may be stacked within the SteriTite container system as follows: up to two (2) instrument baskets or four (4) trays may be stacked within the SteriTite container. Caution: External stacking was not tested. Please do not stack SteriTite containers on top of each other in Steris Amsco V-PRO1. Placement of SteriTite Containers in the Steris Amsco V-PRO 1 low temperature Sterilization System: Case Medical recommends that its containers be placed flat on the sterilizer shelf. All models of SteriTite containers can be placed on each of the two shelves within the Steris Amsco V-PRO 1 low temperature Sterilization System. However, only one shelf can be used to accommodate an 8" high perforated base SteriTite container, because of height restrictions within the sterilizer s chamber. MediTray Products including MediTray inserts, instrument baskets, stacking trays, BackBone silicone brackets, stainless and aluminum brackets, posts and partitions may be used in Steris Amsco V-PRO 1 low temperature Sterilization System. Caution: In Steris Amsco V-PRO 1 low temperature Sterilization System use only compatible materials and instruments as stated in the Steris Amsco V-PRO 1 low temperature Sterilization System Operating Manual. Consult with your instrument manufacturer for the compatibility of various materials in Steris Amsco V-PRO 1 low temperature Sterilization System. Refer to Steris Amsco V-PRO 1 low temperature Sterilization System Operating Manual, instructions for use and labeling. Copyright 2010 Case Medical, Inc. Page 6./ Revision. M