Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36

Similar documents
212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad

HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay

Programmable Safety Systems PSS-Range

Emergency Stop Devices

GAS STOVE GUARD for natural gas and propane stoves

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

C-887.MC Hexapod Control Unit

How to operate TBC-553L

AWNING CONTROL KIT 98GCK-33B

12V MOTION SENSOR 98GC779G INSTALLATION & PROGRAMMING GUIDE REV RV AWNING PRODUCTS

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

Toyostove Error Code EE 2 (EE 6)

www MK-Electronic de 7. Parts catalog How to use this parts catalog , -220, -230 The following legend is used in the parts catalog:

Safety Interlock Switches

TRT800 ATC Transponder Mode A, A-C, S P/N 800ATC-(1XX)-(1XX) Operation Manual. Document No.: e Revision 1.00 Datum:

SPEDESTER Series QUICK REFERENCE GUIDE

Electronic Temperature Controls

General-Use Auto-Tuning HPX-T Series

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

Hiway Gateway Specification and Technical Data

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

INSTRUCTIONS FOR USING THIS SAMPLE FLIGHT MANUAL SUPPLEMENT

1224 Splitter and CTO combo, setup instructions using the Panelview HMI

User manual for awning blind AMZ Z-Wave

AFC-50 Automatic French Fry Cutter Instruction Manual

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL

Est A TRADITION OF EXCELLENCE INSTRUCTION BOOK.

ORTHOPEDIC, TRAUMA TOURNIQUETS AND CUFFS

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

EPM Series Reversing Electric Actuators

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

The Control Display Unit is the pilot s interface with the various functions of the FMS-3000 system.

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

How to operate TBC-50H

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

WITH DIRECT RESPONSE ELECTRONICS. Printed From. Introduction... 2

VMS 100 Volume Measurement System

6275-S1 PNEUMATIC DRILL OPERATING MANUAL ORIGINAL INSTRUCTIONS. P/N November 2014 Revision 1

Alpha Systems AOA Classic & Ultra CALIBRATION PROCEDURES

Display Systems. 1. General. A. Multi-Function Display (MFD) B. Primary Flight Display (PFD)

ORDER FORM B B2100

Sow Management. Modern housing and feeding systems

Instructions for Continued Airworthiness GDL 84/88 Part 23 AML STC as installed in. (Make and Model Airplane)

JetCat USA 4250 Aerotech Center Way, Building G Paso Robles, CA 93446

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Product information Truma VarioHeat and E-Kit. July 2018

Model Crosspoint Matrix

110V DIRECT RESPONSE. Installation & Operations Manual

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Primrose Awnings - Full Cassette Manual & Electric Instructions

Safety and process lock Knox

Trapped Key Transfer System SHGV SVM SVE

AD-500. Telephone Entry & Access Control System. Installation Instructions AD500 Install instruct 1/14/06 10:38 AM Page 1

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

NEWMAR SERVICE SCHOOL

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia. Tel: Fax:

S36 230V MOTOR COVER

Model. Oasis Automatic and Manual RV Door Awning System INSTALLATION & OPERATING INSTRUCTIONS

CASM electric cylinders

How to operate TC-38A

Digimatic Holtest SERIES 468 Three-Point Internal Micrometers

quick and easy installation guide

Lab Skills: Introduction to the Air Track

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

ECOSYS M6026cdn ECOSYS M6526cdn

A3200 Automation Controller Hardware Manual

INVENTOR S KIT MAKING A PEDESTRIAN CROSSING. FOR BBC micro:bit ADDITIONAL EXPERIMENT EXPERIMENT 11.

Special edition paper Development of a Crew Schedule Data Transfer System

Quick Start Guide 3500 AquaVent

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Cover...0. Page #...0 TOC Index.0. Inside Back Cover..0. Outside Back Cover 0

The following figures provide you with a look at the DRAC and some preliminary information.

WITH DIRECT RESPONSE ELECTRONICS

Purpose. Contents. Getting Started Guide Page 1 of 16 Avionics in N /24/2014

Adaptive Noise Cancellation using the LMS Algorithm. December 7, 1999

Nordic ID HH53 User Guide Version 1.0 NORDIC ID HH53 USER GUIDE

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia. Tel: Fax:

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Issue 8. Module TW8. Level crossings - drivers instructions. GERT8000-TW8 Rule Book

Feature. Model comment JG 3NA B L - B - D3

Form 91 Application for Approval of an EFB System

Powerful Recycling. AZR-K single-shaft shredder and RSM granulator. economical robust powerful. Entsorgungstechnik

Flight Evaluation Schedule For GPS IFR Approval Primary Means Enroute, Terminal and Non-Precision Approach

Ultramodern remote control technology for your patio comfort. Comfortable WeiTronic remote control.

HEATER POWER CONTROLLER

METCALFE EC12. Electrically Operated Potato Chipping Machine INSTRUCTION MANUAL

RMC1E - Variable Flame Height EASY Control

2018/09/01 05:24 1/1 Flight Plan

MBM StitchFold Trimmer

Model Number Structure

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility

Table Legs & Extensions 7.1

With our PES/PSS+USB system. everybody gets a great experience!

UM1868. The BlueNRG and BlueNRG-MS information register (IFR) User manual. Introduction

Transcription:

Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36 1.Summary This counter can interface with Screw Feeder FM-36 by setting the number of batches/screws, to be fed, directly into this device or else from a PLC. 2.Specifications 2.1 Product specifications Power supply AC adapter DC24V 1.9A (AC100V~240V) Operating environment Input 8 points / Output 8 points I/O terminal Dimensions 155mm 113mm 44mm 2.2 Parts description 2 8 9 1 FIG1. Machine features 4 3 7 6 5 10 1 [DC24V] :Power supply connector (Marushin Electric Mfg:MJ-20) Input terminal for power supply: DC24V. Synchronized ON/OFF power with the FM36 screw feeder connector. 24V and GND on the terminal block are Output terminals. 2 [FM36] :Interface connector (Tajimi Electronics:PRC05-P8F) Cable connection to screw feeder. 3 [POWER] :LED Light indicates when power is ON. 4 [L/R-SW] :Changing switch Choose between Local Mode or Remote Mode. Choose the mode when the power is OFF. Local Mode: feeds the number of screws set directly on the counter. Remote Mode: feeds the set number of screws set using an external signal. p. 1

5 [Local] :LED Light indicates Local Mode. 6 [Remote] :LED Light indicates Remote Mode. 7 [INPUT]&[OUTPUT] :Input & Output signal terminal block(omron:xw4e-10b1-v1) Can be used on Remote Mode with an external device such as a PLC. 8 [Counter] :Indicator Displays the number of screws the feeder is to supply. Each mode has a different display. Confirm with the respective descriptions. 9 [Complete] :LED Light indicates when feeding the set number of screws is completed. 10 [Overload] :LED Lights indicates when the screw feeder is overloaded and stopped. 2.3 Input & Output signal terminal block FIG 2. Input & Output signal terminal block [INPUT] Terminal specifications [24V]: DC24V Output terminal [IN1]: Input terminal for starting signal of screw feeding [IN2]: 1st bit input terminal [IN3]: 2nd bit Input terminal [IN4]: 3rd bit Input terminal [IN5]: 4th bit Input terminal p. 2

[IN6]: 5th bit Input terminal [IN7]: 6th bit input terminal [IN8]: 7th bit Input terminal [GND]: Ground (0V Output) terminal for [24V] Confirm with Appendix 1 on how to set the number of screws to be fed as well as IN2~8 signals. p. 3

[OUTPUT] Terminal Specifications [24V]: DC24V Output terminal [OUT1]: Output terminal for Request signal of Starting signal for screw feeding. 2 seconds after screw extraction, the output signal changes. [OUT2]: Output terminal signaling the set number of screws are to be extracted. For at least 2 sec., the output signal indicates Low output. [OUT3]: Output terminal signaling the set number of screws are to be extracted. [OUT4]: Output terminal for the 1st request of the starting signal after the power is turned ON. [OUT5]: Output terminal signaling the screw feeding operation. [OUT6]: Output terminal for the 2nd or later request of the starting signal after the power is turned ON. [OUT7]: Output terminal for the overload and stopped signal. [OUT8]: Output terminal for the extracting error and stopped signal. [GND]: Ground (0V Output) terminal for [24V] Internal circuits The internal circuits for both the INPUT and OUTPUT terminals are described below in Figures 3 and 4. In FIG 3 & 4, 24V and GND are [24V] and [GND] terminals. [24V] and [GND] on INPUT and OUTPUT use their respective terminals. IN * terminal OUT * terminal FIG 3. [IN*] terminal FIG 4. [OUT*] terminal p. 4

3.Operations 3.1 Local mode Operation sequences When the set number of screws are extracted from the feeding site, another set is delivered. Counter display and operation On Local Mode, the counter displays as in Fig. 5. Cumulated number Set number Button A Button B Button C FIG 5. Counter display on Local Mode The right side of the display is the set number of screws to be fed. When screw feeding starts,the number counts down. The left side of the display is the cumulated number of times the set number has been fed. 1 Clearing the cumulated number counter. Push Button B continuously until the number returns to "0000". 2 Setting the number of screws to be fed. When the cumulated number counter is at "0000", push Button B until the tens digit is flashing, then every push of Button B changes the tens digit number. Push Button C until the single digit is flashing, then every push of Button C changes the single digit number. p. 5

3 Buzzer Volume Setting Push Buttons A and C together until the display changes to "bu". (see Fig. 6) Next push Button C only, to increase the volume from "00 ~ 03". The displayed buzzer volume number is set and then the display will return to normal. Buzzer volume setting FIG 6. Counter display when the buzzer volume is being set. (note "bu") 3.2 Remote Mode Operation sequences Refer to Timing Chart 1(page 9) for details of the operation. Check the level of electricity, of the feeding operations, on OUT1 & 2. Check the condition of the feeder on OUT3 & 8. Counter display and operation Detecting a starting signal resets the counter to (00). When screws are fed, the counter increases to the set number. On Remote Mode, you can't clear the counter with the buttons, but can change the buzzer volume. Feeding number FIG 7. Counter display on Remote Mode (note "Pc") p. 6

4.Abnormal stop 4.1 Irregular extracting stop When screws are taken out before the set number of screws are fed, the machine decides it's an irregular extracting, and it stops feeding. On Remote Mode, after detecting an irregular extraction, OUT8 changes from HI output to Low output. Restarting operations are different for each mode. On Local Mode When detecting the extraction site closed, the operation restarts and the counter is reset to zero. On Remote Mode After an irregular stop, if the extracting drawer is opened and closed, the machine will restart. Details are found on Timing Chart 2 (page 10). 4.2 Overload stop When the screw feeder indicates an Overload stop signal, the Overload LED lights up. On Remote Mode, after the overload signal is detected, the terminal OUT7 changes from HI to Low. Details are found on Timing Chart 3 (page 11). To restart, switch ON the power. Shut the power OFF to resolve any problems such as reducing the amount of screws in the hopper. Then turn the power ON again to restart. p. 7

5.Miscellaneous 5.1 Accessories AC adapter 1 Manual book 1 Screw feeder interface cable (approx 1m) 1 Note: Interface cable specifications Connector: (Tajimi Electronics) PRC05-P8M 2 Cable connection : 8 wick straight 5.2 Connector specifications Connector code Maker Model number [DC24V] Marushin Electric Mfg. Co., Ltd. MJ-20 [FM36] Tajimi Electronics Co., Ltd. PRC05-P8F [INPUT] Omron XW4E-10B1-V1 [OUTPUT] Omron XW4E-10B1-V1 p. 8

Appendix 1. Screw number settings and Input signals. Setting number IN8 IN7 IN6 IN5 IN4 IN3 IN2 0 HI HI HI HI HI HI HI 1 HI HI HI HI HI HI Low 2 HI HI HI HI HI Low HI 3 HI HI HI HI HI Low Low 4 HI HI HI HI Low HI HI 5 HI HI HI HI Low HI Low 6 HI HI HI HI Low Low HI 7 HI HI HI HI Low Low Low 8 HI HI HI Low HI HI HI 9 HI HI HI Low HI HI Low 10 HI HI HI Low HI Low HI 11 HI HI HI Low HI Low Low 12 HI HI HI Low Low HI HI 13 HI HI HI Low Low HI Low 14 HI HI HI Low Low Low HI 15 HI HI HI Low Low Low Low 16 HI HI Low HI HI HI HI 17 HI HI Low HI HI HI Low 18 HI HI Low HI HI Low HI 19 HI HI Low HI HI Low Low 20 HI HI Low HI Low HI HI 21 HI HI Low HI Low HI Low 22 HI HI Low HI Low Low HI 23 HI HI Low HI Low Low Low 24 HI HI Low Low HI HI HI 25 HI HI Low Low HI HI Low 26 HI HI Low Low HI Low HI 27 HI HI Low Low HI Low Low 28 HI HI Low Low Low HI HI 29 HI HI Low Low Low HI Low 30 HI HI Low Low Low Low HI 31 HI HI Low Low Low Low Low 32 HI Low HI HI HI HI HI 33 HI Low HI HI HI HI Low 34 HI Low HI HI HI Low HI 35 HI Low HI HI HI Low Low 36 HI Low HI HI Low HI HI 37 HI Low HI HI Low HI Low 38 HI Low HI HI Low Low HI 39 HI Low HI HI Low Low Low 40 HI Low HI Low HI HI HI 41 HI Low HI Low HI HI Low 42 HI Low HI Low HI Low HI 43 HI Low HI Low HI Low Low 44 HI Low HI Low Low HI HI 45 HI Low HI Low Low HI Low 46 HI Low HI Low Low Low HI 47 HI Low HI Low Low Low Low 48 HI Low Low HI HI HI HI 49 HI Low Low HI HI HI Low 50 HI Low Low HI HI Low HI 51 HI Low Low HI HI Low Low 52 HI Low Low HI Low HI HI 53 HI Low Low HI Low HI Low 54 HI Low Low HI Low Low HI 55 HI Low Low HI Low Low Low 56 HI Low Low Low HI HI HI 57 HI Low Low Low HI HI Low 58 HI Low Low Low HI Low HI 59 HI Low Low Low HI Low Low 60 HI Low Low Low Low HI HI 61 HI Low Low Low Low HI Low 62 HI Low Low Low Low Low HI 63 HI Low Low Low Low Low Low

Timing Chart 1 Regular operation [OUTPUT/INPUT colored areas are Low output.] LED POWER Complete Flashing OverLoad OUTPUT OUT1 Request 1 4 1 4 OUT2 Waiting to extract 2 3 OUT3 Waiting to extract OUT4 Request 1 OUT5 Mid-operation OUT6 Request 2 OUT7 Overloaded OUT8 Irregular extracting INPUT IN1 Starting 5 5 IN2 1st bit IN3 2nd bit IN4 3rd bit IN5 4th bit Depends on setting IN6 5th bit IN7 6th bit IN8 7th bit External operation Power ON Extracting Internal operation Setting screw number Feeding motion Count completed Waiting 1:2 seconds after detecting an input signal on IN1, OUT1 changes. 2,3:OUT2 doesn't change at least for 2 seconds. 4:2 seconds after OUT2 changed, OUT1 changes. 5:When OUT1 is Low output, screw number (IN2~8) is set by switching H/L on IN1.

Timing Chart 2 Irregular extracting stop and restarting operation Screws taken out before the set number results in an irregular extracting and the machine stops. For restarting, do as follows. Reset the PLC to the original, desired operation. After detecting an irregular extracting, it remains in OUT1 and so must be reset to the original desired operation. [OUTPUT/INPUT colored areas are Low output.] LED POWER Complete OverLoad Flashing Flashing OUTPUT OUT1 Request 1 1 3 OUT2 Waiting to extract 2 OUT3 Waiting to extract OUT4 Request 1 OUT5 Mid-operation OUT6 Request 2 OUT7 Overloaded OUT8 Irregular extracting INPUT IN1 Starting 4 4 IN2 1st bit IN3 2nd bit IN4 3rd bit IN5 4th bit IN6 5th bit Depends on setting IN7 6th bit IN8 7th bit External operation Power ON Extracting 5 6 Internal operation Setting screw number Feeding motion Count completed Waiting 1:2 seconds after detecting an input signal on IN1, OUT1 changes. 2:OUT2 doesn't change for at least 2 seconds. 3:2 seconds after OUT2 changed, OUT1 changes. 4:When OUT1 is Low output, screw number (IN2~8) is set by switching H/L on IN1 5:Screws taken out in mid-feed results in an Irregular Extracting Stop. 6:Restarting solves the irregular extracting stop.

Timing Chart 3 Overload stop When the screw feeder is overloaded, the machine stops. Turn OFF the screw feeder to solve the overload problem, then turn the power ON again. Reset the PLC to the original, desired operation. [OUTPUT/INPUT colored areas are Low output.] LED POWER Complete OverLoad Flashing Flashing Flashing OUTPUT OUT1 Request OUT2 Waiting to extract OUT3 Waiting to extract OUT4 Request 1 OUT5 Mid-operation OUT6 Request 2 OUT7 Overloaded OUT8 Irregular extracting INPUT IN1 Starting 4 5 IN2 1st bit IN3 2nd bit IN4 3rd bit IN5 4th bit Depends on setting IN6 5th bit IN7 6th bit IN8 7th bit External operation Power ON Power OFF Extracting Internal operation Setting screw number Feeding motion Count completed Waiting

OHTAKE-ROOT KOGYO CO., LTD. 27 Kanegasaki, Hagisho Ichinoseki, Iwate 021-0902 Japan TEL: +0191-24-3144 FAX: +0191-24-3145 Mail: office@ohtake-root.co.jp http://www.ohtake-root.co.jp 2015-08