IDEXX Summary. D P Sartory and C Allaert Vandevenne

Similar documents
Addressing challenges associated with the detection of faecal coliform organisms in water matrices. Neil Leat Rand Water Date 30/09/2014

COLILERT - WHAT'S AL THE FUSS ABOUT? Elizabeth Hanko. Elizabeth Hanko, Senior Consultant. AWT, Victoria

Colilert * -18 A faster, easier way to test for total coliforms and E. coli

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

Drinking Water Microbiology 2010:2, September

NordVal International / NMKL c/o Norwegian Veterinary Institute PB 750 Sentrum, 0106 Oslo, Norway

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Protecting Consumers. Improving lab efficiency. 3M Petrifilm Plates and Reader

Interpretation Guide

3M Food Safety 3M Petrifilm Plates and Reader. Simply. Prompt. Precise. Productive.

Comparison of the Novel ColiPlate

Interpretation Guide

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation

Chromocult Coliform Agar acc. ISO

3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Proficiency Testing. Drinking Water Microbiology. September Tommy Šlapokas NFA PT

Convenient Media Solutions For food and water testing

Pr oject Summar y. Survey of the prevalence of Escherichia coli O157:H7 on the surface of subprimal cuts of beef during winter months (Phase I)

Interpretation Guide. Coliform Count Plate

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

Detection of Total Coliforms, Escherichia coli, and

Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Overview of Microbial Indicator Monitoring Lab Methods. Jim Ferretti, USEPA Region 2 DESA, Laboratory Branch May 23, 2018

Food Microbiological Examination: Enumeration of Coliforms

User friendly microbial detection! Sanita-kun R =The ready-to-use cultural medium sheet for the microbial detection =

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

Enumeration of Total Coliforms

Kit Information 3. Sample Preparation 4. Procedure 4. Analysis of Results 5. Quality Control 6. Disposal 6. Technical Support 6. Order Information 6

REC. Interpretation Guide. Rapid E. coli/coliform Count Plate

Proficiency Testing. Drinking Water Microbiology. March by Tommy Šlapokas NFA PT

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation BSK Associates Vancouver

Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria

Water Quality Trends for Conscience Bay

Bacteriological testing of water

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Water Quality Trends for Patchogue Bay

No Longer Fond of the Local Pond

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

Issue Date: March 1, M Petrifilm Plates Certifications, Recognitions and Validations

The Mercer Island E. coli Event PNWS AWWA Spring Conference Bellevue Washington 2015

Sampling for Microbial Analysis

There are 7 kinds of unique dry medium for hygienic testing and detection of food poisoning bacteria.

CERTIFICATE OF ACCREDITATION

Bacterial Quality of Crystalline Rock and Glacial Aquifers in New England

CERTIFICATE OF ACCREDITATION

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

Project Summary. Principal Investigators: Chance Brooks, Mindy Brashears, Mark Miller, Alejandro Echeverry, and Cassandra Chancey

FECAL COLIFORM MONITORING IN GRAYS HARBOR COUNTY: SUMMARY REPORT OF MONITORING RESULTS FOR

PHE Food and Water Microbiology External Quality Assessment Schemes

OF DRINKING WATER BACTERIOLOGICAL SURVEILLANCE USACHPPM TECHNICAL GUIDE NO. 224

Coliforms as Indicator of Faecal Pollution

Design of E. coli O157:H7 sampling and testing programs by Industry

This document is a preview generated by EVS

Indicator organisms. !Group of microorganisms use to reflect the quality and safety of a process food product

E. coli and Coliform Bacteria Levels of Edgewood s Watershed Katie Schneider and Leslie Reed

Fecal Coliform Bacteria Monitoring for the Sleepy Creek Watershed Incremental 319 Project Final Report

COMMISSION IMPLEMENTING REGULATION (EU)

CERTIFICATE OF ACCREDITATION

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

Aerodrome Certification Applicable provisions

Productivity. Technician. Maximized. Interpretation Guide

TACWA September Meeting CHALLENGES IN MEETING THE TEXAS BACTERIAL LIMITS WITH UV ALONG THE COAST AND BAYS. Gennady Boksiner, P.E. September 30, 2011

COMMISSION OF THE EUROPEAN COMMUNITIES. Draft. COMMISSION REGULATION (EU) No /2010

PHE Food and Water Microbiology External Quality Assessment Schemes

Microbiological Quality of Ice for Cooling Drinks

CITY OF LYNDEN STORMWATER MANAGEMENT PROGRAM REPORT MARCH 1, 2016

ECOLABELLING of Portable Rechargeable Batteries

Asia Pacific Regional Aviation Safety Team

Changes in Surviving E.coli, Coliform Bacteria and General Bacteria in Manure with Air Drying Treatment

Evaluation of Membrane Filters for the Determination of Numbers of Coliform Bacteria in Waterl

Proficiency Testing FINAL REPORT Check sample program 16CSP02 February 2016

Bacterial Interference with Coliform Colony Sheen Production on

Bacteriological Analysis of Drinking Water in Port Sudan City, Red Sea State, Sudan

AIRWORTHINESS PROCEDURES MANUAL CHAPTER 26. Modifications and Repairs

Comparison of Enterococci and Coliform Microorganisms in

Project Summary. Principal Investigators: Lawrence D. Goodridge 1 ; Phil Crandall 2, and Steven Ricke 2. Study Completed 2010

The Microbiological Survey of Potential Water Borne Pathogens in Fresh Water Springs of the Selected Community Located in the Upolu Island, Samoa

APAT Italian National Agency for the Protection of the Environment and for Technical Services CAMPING SITE SERVICE EU ECO-LABEL AWARD SCHEME

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

ISO INTERNATIONAL STANDARD. Protective clothing Aprons, trousers and vests protecting against cuts and stabs by hand knives

Official Journal of the European Union L 7/3

Tufts University Water: Systems, Science, and Society (WSSS) Program

The PIANC RIS guidelines Edition 4, 2018 Cas Willems (Chairman PIANC WG 125) Smart Atlantis on behalf of Rijkswaterstaat

Alberta Agriculture and Forestry s Response to the 2014 Outbreak of E. coli O157:H7 in Alberta

Bacterial Occurrence in Kitchen Hand Towels

REVISIONS IN THE SPANISH INTERNATIONAL VISITORS ARRIVALS STATISTICS

VALIDATION OF DRY-AGING AS AN EFFECTIVE INTERVENTION STEP AGAINST ESCHERICHIA COLI O157:H7

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Official Journal L 362. of the European Union. Legislation. Non-legislative acts. Volume December English edition. Contents REGULATIONS

CERTIFICATE OF ACCREDITATION

AQIS MEAT NOTICE. Last Notice this Category

- *".' , / SI'UDIES ON BA4CrrERIAL INDICATORS OF IN DKINKING WA'I'EK

Official Journal of the European Union L 146/7

Sample Regulations for Water Aerodromes

Proficiency Testing. Food Microbiology. January Laurence Nachin, Christina Normark and Irina Boriak

ISO INTERNATIONAL STANDARD. Non-invasive sphygmomanometers Part 1: Requirements and test methods for non-automated measurement type

Transcription:

IDEXX Summary 2T Topic Title Authors Review of studies in France leading to AFNOR Certification Validation mark for Colilert -18 / Quanti-Tray for the testing of drinking water samples Improved methods for detecting E. coli and coliforms in drinking water: AFNOR validation of Colilert -18/Quanti- Tray Date November 2009 Highlights D P Sartory and C Allaert Vandevenne In France, in order to be granted the use of the AFNOR Validation mark, Colilert-18 / Quanti- Tray underwent rigorous studies focused on the comparison of the IDEXX method with the standardized reference method (ISO 9308-1) Based on the results of these studies, AFNOR Certification granted IDEXX the use of the AFNOR Validation mark as discussed and described in the attached paper Per AFNOR Certification guidelines, a preliminary study was conducted where the relative accuracy, linearity, detection and quantification limits, selectivity (inclusivity and exclusivity) and practicability of the Colilert-18/Quanti-Tray method were assessed using samples of distribution water and fountain water spiked with strains of both coliform bacteria and E. coli. All the assessed performance characteristics of the Colilert-18/Quanti-Tray system were found to be satisfactory Subsequent to the preliminary study, an inter-laboratory study was conducted; 13 laboratories were sent samples inoculated at various levels of contamination with a strain of E. coli originally isolated from water. Samples were analyzed by both NF EN ISO 9308-1 method and Colilert- 18/Quanti-Tray. Results from each method were then statistically compared and were found to be statistically equivalent Official AFNOR Certificate can viewed here or viewed on the IDEXX website here AFNOR- Validation mark for Colilert-18/Quanti-Tray

Improved methods for detecting E. coli and coliforms in drinking water: AFNOR validation of Colilert -18/Quanti-Tray D P Sartory 1 and C Allaert Vandevenne 2 1 SWM Consulting, Little Ness, Shrewsbury, UK E-mail: david.sartory@tesco.net 2 IDEXX Laboratories, Av. Acàcies, nº4, Alella 08328, Spain E-mail: corrie-allaert@idexx. com Summary Escherichia coli (E. coli) and the related coliform bacteria are the most important parameters in the testing of drinking water. In France the detection and enumeration of these bacteria has for many years been based on growth on TTC-Tergitol agar (NF EN ISO 9308-1). Recent developments in the detection of enzymes specific for E. coli and coliforms have led to the development of more accurate, rapid methods. One method, the IDEXX Colilert -18/Quanti-Tray system, has recently been validated in accordance with an AFNOR certification protocol. The method was found to be statistically equivalent to NF EN ISO 9308-1, and gave accurate confirmed results within 18 hours, instead of 48 72 hours. E. coli and coliform testing of drinking water In 1885 Theodor Escherich described the bacteria Bacterium coli commune and Bacterium lactis commune which had been isolated from faeces. Shortly afterwards, in 1892, Franz Schardinger, in Vienna, proposed the testing of water for Bacterium coli (now Escherichia coli), since it was found abundantly in faeces and its absence in water would, therefore, indicate the absence of faecal contamination and, hence, the absence of enteric pathogens. It was soon realised that there was a whole group of related bacteria similar to E. coli that could be found in human and animal faeces and contaminated water. This group of bacteria, which includes E. coli, was given the name coliform bacteria. So started the long history of testing for E. coli and coliform bacteria as the principal indicators in assessing the sanitary safety of water. For over 100 years now E. coli and the related coliform bacteria have been the key bacterial indicators for assessing the microbiological quality of drinking water and environmental waters. E. coli is regarded as the primary indicator of faecal contamination and, hence, a potential health risk with consumption of contaminated water. Standards for drinking water based on the absence of E. coli and coliform bacteria were soon adopted in several countries in Europe and North America, typically based on their absence in a 100 ml test volume of sample. This is still the case with current legislation being based on the European Drinking Water Directive (Council Directive 98/83/EC) which has been incorporated into national legislation by the Member States of the European Union. This Directive additionally specified for the first time the methods that were to be used for the microbiological parameters for regulatory monitoring. For E. coli and coliform bacteria the method cited is the current ISO/CEN standard NF EN ISO 9308-1. Although this method is not widely used in Europe, in France it is the only method allowed to be used for compliance testing of drinking water. The Directive additionally states that alternative methods may be used, provided that the results obtained are at least as reliable as those produced by the methods specified. Also, recent developments in the detection of enzymes specific for E. coli and coliforms have led to a change in the definitions for these bacteria and this has led to the development of more accurate, easy to use and rapid methods. Since 2000 a number of studies have been undertaken in several European countries comparing the performance of alternative methods with the NF EN ISO 9308-1. Acceptance of the performance of several alternative methods has been agreed upon by the Expert Group on Microbiology which advises the European Commission on microbiological aspects of the Drinking Water Directive. These include the Colilert -18/Quanti-Tray system (for example in Germany, Spain and the UK), membrane-lactose glucuronide agar (in the UK) and lauryl sulphate agar (in the Netherlands). Until now there have been no approved alternative methods for the detection and enumeration of E. coli and coliform bacteria from drinking water in France. 1

Methods for detecting E. coli and coliforms in drinking water Traditionally, E. coli and coliform bacteria have been detected in water using media that allow demonstration of the fermentation of lactose. This is the basis of the NF EN ISO 9308-1 method with the TTC-Tergitol agar medium. This medium contains lactose which when fermented produces acid that is detected as a change in colour around the colony from red to yellow. In France the tests are incubated for up to 48 hours, and if colonies are present they are termed presumptive as they must be tested by a confirmation test. For E. coli this involves the demonstration of production of indole from tryptophan and takes a further 24 hours. A confirmed result for E. coli can take up to 72 hours to obtain. Today the approach for detecting E. coli and coliforms is more often based on the detection of specific enzymes: β-galactosidase (involved in the fermentation of lactose) for the detection of coliform bacteria and β-glucuronidase for the specific detection of E. coli. This approach has been adopted by the ISO working group responsible for deriving standards for the detection and enumeration of E. coli and coliforms in water. The first step in lactose fermentation is the splitting of the molecule into glucose and galactose by β- galactosidase, an enzyme expressed by the great majority of coliform bacteria. As it is simple to test for the presence of β-galactosidase using chromogenic or fluorogenic substrates that are readily taken up by cells, a number of methods based on this approach have been developed over the last 20 years. A widely used chromogenic substrate for β-galactosidase is o-nitrophenyl-β-dgalactopyranoside (ONPG) which produces a yellow colour when split by the enzyme (Figure 1). This is the basis of a number of methods for coliform bacteria, including the IDEXX Colilert -18/Quanti- Tray system. Basing the definition of coliforms on a single diagnostic enzyme that is indicative of the actual or potential ability of the bacterium to ferment lactose results in a definition that is microbiologically acceptable. The ISO working group on methods for E. coli and coliforms has agreed on a definition for a coliform as being a member of the Enterobacteriaceae that expresses β- galactosidase and this will be the basis for the development of any future standards. Figure 1: Detection of coliform bacteria β-galactosidase using ONPG In addition to β-galactosidase, E. coli expresses the enzyme β-glucuronidase which is very rarely expressed by other coliform bacteria. Detection of this diagnostic enzyme for E. coli has become well established for food and water testing, particularly using the fluorogenic substrate 4- methylumbelliferyl- β-d-glucuronide (MUG) (Figure 2). The ISO working group has agreed that E. coli be simply defined as a member of the Enterobacteriaceae that expresses β-galactosidase and β- glucuronidase. This is a more microbiologically correct definition for E. coli than the one based on lactose fermentation and production of indole from tryptophan. ISO s new definition is also the basis for E. coli detection by the Colilert -18/Quanti-Tray system. There are two basic approaches to processing of samples for analysis of E. coli and coliforms. The first is membrane filtration, which is the basis of NF EN ISO 9308-1, where the bacteria are trapped on a membrane filter which is then placed on medium for selective growth of the target bacteria. The alternative approach is the multiple tube most probable number (MPN) method where aliquots of sample are dispensed into a series of tubes containing media and incubated. The number of positive 2

tubes is statistically related to the number of coliforms or E. coli present. This is also the basis of Quanti-Tray where the tubes have been replaced with a reaction pouch, that divides the sample into a series of wells (Figure 3). For drinking water, the pouch is divided into 51 wells, giving a much more accurate MPN count than the traditional multiple tube method of ISO 9308-2. Figure 2: Detection of E. coli β-glucuronidase using MUG Figure 3: Examples of modern MPN format methods for E. coli and coliform bacteria the 51- well Colilert -18/Quanti-Tray (foreground) and the 97-well Colilert -18/Quanti-Tray (background). Validation of Colilert -18/Quanti-Tray in France New alternative methods must be validated prior to adoption. Validation is when the performance characteristics of the alternative method are defined. If the performance characteristics are satisfactory then a comparative study is undertaken where the performance of an alternative method is compared to that of a reference method. The reference method for drinking water is NF EN ISO 9308-1. The Colilert -18/Quanti-Tray system has been validated against the reference method in a study using a recently developed AFNOR protocol based on FD ENV ISO 13843 (on validation of microbiological methods for water analysis) and NF EN ISO 16140 (on validation of alternative methods for food analysis). AFNOR protocols have been developed for validating food methods for 3

several years, but this is the first time that a new validation protocol has been applied to drinking water samples with the goal of certifying an alternative method for drinking water testing. A preliminary study was conducted where the relative accuracy, linearity, detection and quantification limits, selectivity (inclusivity and exclusivity) and practicability of the Colilert -18/Quanti-Tray system were assessed using several samples of distribution water and fountain water spiked with strains of both coliform bacteria and E. coli. All the assessed performance characteristics of the Colilert - 18/Quanti-Tray system were found to be satisfactory. On completion of the preliminary study an interlaboratory study was conducted where participating laboratories were sent samples inoculated at various levels of contamination with a strain of E. coli originally isolated from water. These samples were analysed by both the NF EN ISO 9308-1 method and Colilert -18/Quanti-Tray. The results from each method were then statistically compared. The Colilert -18/Quanti-Tray method was found to be statistically equivalent to the NF EN ISO 9308-1 method, particularly for low to medium counts that could be expected from drinking water samples. Colilert -18/Quanti-Tray, however, did on average give slightly higher counts, indicating greater accuracy. The validation study has been reviewed and passed by the AFNOR Technical Board which is composed of a president, a secretary, a representative of AFNOR standards, and representatives of manufacturers, users and public authorities. Conclusions The AFNOR validation study demonstrated that Colilert -18/Quanti-Tray is a suitable alternative method to the current NF EN ISO 9308-1 method. As this method is based on the revised ISO definitions of E. coli and coliform bacteria, it is by definition more accurate, since it finds all the bacteria that are included in the new definitions. In addition, it has the advantage of not requiring a confirmation test, like NF EN ISO 9308-1. Consequently, confirmed results are available after 18 hours incubation compared to the 48 72 hours needed for the reference method NF EN ISO 9308-1. Its widespread use under acceptance for compliance drinking water testing in 16 European and 38 countries worldwide has shown it to be much more convenient and easy-to-use than the reference method. Colilert -18/Quanti-Tray is produced in a ISO 9001:2000 certified facility that has been recently inspected by an AFNOR auditor, who passed it with high praise. Colilert -18/Quanti-Tray has been accepted for compliance testing of drinking water in several countries, including the USA, UK, Germany, Italy, Spain and Denmark. References AFNOR (2000) Qualité de l eau Recherche et dénombrement des Escherichia coli et des bactéries coliformes - Partie 1 : méthode par filtration sur membrane. NF EN ISO 9308-1. Agence Française de Normalisation, Paris, France. AFNOR (2001) Qualité de l eau Lignes directrices pour la validation des méthodes microbiologiques. FD ENV ISO 13843. Agence Française de Normalisation, Paris, France. AFNOR (2003) Microbiologie des aliments Protocole pour la validation des méthodes alternatives. NF EN ISO 16140. Agence Française de Normalisation, Paris, France. AFNOR (2009) Validation project revision 29.05.2009 Application à l analyse microbiologique de l eau Protocole de validation d une méthode alternative commerciale par rapport à une méthode de reference. EUROPEAN UNION (1998) Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption. Official Journal of the European Communities 1998, 5.12.98, L330/32-L330/53. 4

Journal de la République Française: Ministère de la santé, de la famille et des personnes handicapées. Arrêté du 17 septembre 2003 relatif aux methods d analyse des échantillons d eau et à leurs caractéristiques de performance. Annexe 1 Méthodes pour l analyse des eaux destinées à la consummation humaine. ISO (1990) Qualité de l eau Recherche et dénombrement des organismes coliformes, des organismes coliformes thermotolérants et des Escherichia coli présumés Partie 2 : méthode du nombre le plus probable. Norme internationale ISO 9308-2:1990. Organisation Internationale de Normalisation, Genève, Suisse. 5