JANUARY, 217 FEATURES - CURTAIN WALL 1 Fascia Blade Outrigger Features Standardized solution for seamless integration with 16 Wall System TM 1, 16 Wall System TM 2, 16UT System TM 1, 16 Wall System TM 5, 16 SS, 16 SS SSG and 163 SS IR. Tested for combined wind, snow and dead loads 3" (762 mm) and 36" (914.4 mm) deep Outriggers are standard Fully pre-engineered 9 and 135 inside and outside corners Thermally broken attachment method for 16 Wall System TM 1, 16UT System TM 1, 16 SS, 16 SS SSG and 163 SS IR. 16 Wall System TM 2 and 16 SS SSG allow 2 sided SSG. Attachment bracket designed to accept shallow and deep covers Easy to use Load Charts quicken design process Refreshing new blade options, with tubular profiles for spanning wider openings 44 different combinations of outrigger and blade styles allow aesthetic & shading performance flexibility Qualified for up to 3 different LEED Certification criteria Permanodic TM anodized finishes in seven standard choices Painted finishes in standard and custom choices Shading performance can be analyzed by Solector TM Sun Shading Estimator Tool Product Application Curtain Wall Facades Interior aesthetical application For specific product applications, Consult your Kawneer representative.
2 BLANK PAGE JANUARY, 217
JANUARY, 217 INDEX - CURTAIN WALL 3 Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. 16 WALL SYSTEM TM 1...4 16 WALL SYSTEM TM 2...5 16UT SYSTEM TM 1 1" INFILL...6 1-3/4" INFILL...7 16 WALL SYSTEM TM 5...8 16 SS...9 16 SS SSG...1 163 SS IR...11 9 and 135 CORNERS...12,13 SUNSHADE COMBINATIONS...14,15 LOAD CHARTS... 16-18 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI ) units are found in these details: m meter cm centimeter mm millimeter s second Pa pascal MPa megapascal
4 16 WALL SYSTEM TM 1 APPLICATION JANUARY, 217 VERTICAL 36" (914.4) 5" (127) 36" (914.4) SHOWN WITH 36" ROUNDED, AIRFOIL BLADE, BULLNOSE FASCIA, AND SHALLOW COVER. STANDARD 1" (25.4) SHALLOW COVER OPTIONAL 3-1/8" (79.4) DEEP COVER AVAILABLE NOTE: Horizontal sunshades are not recommended directly over entrances and walkways to eliminate any risk of injury due to falling ice or snow. Attachment bracket is painted only and will be painted to match anodized finish. SECTION VIEW THROUGH VERTICAL MULLION
JANUARY, 217 16 WALL SYSTEM TM 2 APPLICATION 5 VERTICAL 36" (914.4) 5" (127) 36" (914.4) SHOWN WITH 36" ROUNDED, AIRFOIL BLADE AND BULLNOSE FASCIA. NOTE: Horizontal sunshades are not recommended directly over entrances and walkways to eliminate any risk of injury due to falling ice or snow. Attachment bracket is painted only and will be painted to match anodized finish. SECTION VIEW THROUGH VERTICAL MULLION
6 16UT SYSTEM TM 1 APPLICATION - 1" INFILL JANUARY, 217 VERTICAL 36" (914.4) SHOWN WITH 36" CURVED, DIAMOND BLADE, CIRCULAR FASCIA, AND SHALLOW COVER. 36" (914.4) 5" (127) STANDARD 1" (25.4) SHALLOW COVER OPTIONAL 3-1/8" (79.4) DEEP COVER AVAILABLE NOTE: Horizontal sunshades are not recommended directly over entrances and walkways to eliminate any risk of injury due to falling ice or snow. Attachment bracket is painted only and will be painted to match anodized finish. SECTION VIEW THROUGH VERTICAL MULLION
JANUARY, 217 16UT SYSTEM TM 1 APPLICATION - 1-3/4" INFILL 7 VERTICAL 36" (914.4) SHOWN WITH 36" WEDGE, CIRCULAR BLADE, ANGULAR FASCIA, AND SHALLOW COVER. 36" (914.4) 5" (127) STANDARD 1" (25.4) SHALLOW COVER OPTIONAL 3-1/8" (79.4) DEEP COVER AVAILABLE NOTE: Horizontal sunshades are not recommended directly over entrances and walkways to eliminate any risk of injury due to falling ice or snow. Attachment bracket is painted only and will be painted to match anodized finish. SECTION VIEW THROUGH VERTICAL MULLION
8 16 WALL SYSTEM TM 5 APPLICATION JANUARY, 217 VERTICAL 36" (914.4) 5" (127) SHOWN WITH 36" SQUARE, WAVE BLADE, RECTANGULAR FASCIA, AND SHALLOW COVER. 36" (914.4) STANDARD 1" (25.4) SHALLOW COVER OPTIONAL 3-1/8" (79.4) DEEP COVER AVAILABLE NOTE: Horizontal sunshades are not recommended directly over entrances and walkways to eliminate any risk of injury due to falling ice or snow. Attachment bracket is painted only and will be painted to match anodized finish. SECTION VIEW THROUGH VERTICAL MULLION
JANUARY, 217 16 SS APPLICATION 9 VERTICAL 36" (914.4) 5" (127) SHOWN WITH 36" ROUNDED, FLARE BLADE, BULLNOSE FASCIA, AND SHALLOW COVER. 36" (914.4) STANDARD 1" (25.4) SHALLOW COVER OPTIONAL 3-1/8" (79.4) DEEP COVER AVAILABLE NOTE: Horizontal sunshades are not recommended directly over entrances and walkways to eliminate any risk of injury due to falling ice or snow. Attachment bracket is painted only and will be painted to match anodized finish. SECTION VIEW THROUGH VERTICAL MULLION
1 16 SS SSG APPLICATION JANUARY, 217 VERTICAL 36" (914.4) 5" (127) SHOWN WITH 36" ROUNDED, FLARE BLADE AND BULLNOSE FASCIA. 36" (914.4) NOTE: Horizontal sunshades are not recommended directly over entrances and walkways to eliminate any risk of injury due to falling ice or snow. Attachment bracket is painted only and will be painted to match anodized finish. SECTION VIEW THROUGH VERTICAL MULLION
JANUARY, 217 163 SS IR APPLICATION 11 VERTICAL 36" (914.4) 5" (127) SHOWN WITH 36" ROUNDED, FLARE BLADE, BULLNOSE FASCIA, AND SHALLOW COVER. 36" (914.4) STANDARD 1" (25.4) SHALLOW COVER OPTIONAL 3-1/8" (79.4) DEEP COVER AVAILABLE NOTE: Horizontal sunshades are not recommended directly over entrances and walkways to eliminate any risk of injury due to falling ice or snow. Attachment bracket is painted only and will be painted to match anodized finish. SECTION VIEW THROUGH VERTICAL MULLION
12 9 CORNERS - CURTAIN WALL JANUARY, 217 9 OUTSIDE CORNER SINGLE MULLION EXAMPLE SHOWN WITH 3" SQUARE, WAVE BLADE, RECTAGULAR FASCIA AND SHALLOW COVER. 9 INSIDE CORNER DOUBLE MULLION EXAMPLE SHOWN WITH 3" ROUNDED, WAVE BLADE, BULLNOSE FASCIA AND SHALLOW COVER. 9 INSIDE CORNER 9 OUTSIDE CORNER 16 Wall System TM 1 Available with Double Mullion Available with Single Mullion and Double Mullion 16 Wall System TM 2 Use 16 Wall System TM 1 Double Mullion Available with Single Mullion 16UT System TM 1 Available with Double Mullion Available with Single Mullion and Double Mullion 16 Wall System TM 5 Available with Double Mullion Available with Double Mullion 16 SS Available with Double Mullion Available with Double Mullion 16 SS SSG Use 16 SS Double Mullion Use 16 Wall System TM 2 Single Mullion 163 SS IR Available with Double Mullion Available with 16 System TM 1 Single Mullion and Double Mullion
JANUARY, 217 135 CORNERS - CURTAIN WALL 13 135 OUTSIDE CORNER SINGLE MULLION EXAMPLE SHOWN WITH 36" CURVED, CIRCULAR BLADE, CIRCULAR FASCIA AND SHALLOW COVER. 135 INSIDE CORNER DOUBLE MULLION EXAMPLE SHOWN WITH 36" CURVED, CIRCULAR BLADE, CIRCULAR FASCIA AND SHALLOW COVER. 135 INSIDE CORNER 135 OUTSIDE CORNER 16 Wall System TM 1 Available with Double Mullion Available with Single Mullion and Double Mullion 16 Wall System TM 2 Use 16 Wall System TM 1 Double Mullion Available with Single Mullion 16UT System TM 1 Available with Double Mullion Available with Single Mullion and Double Mullion 16 Wall System TM 5 Available with Double Mullion Available with Double Mullion 16 SS Available with Double Mullion Available with Double Mullion 16 SS SSG Use 16 SS Double Mullion Use 16 Wall System TM 2 Single Mullion 163 SS IR Available with Double Mullion Available with Double Mullion
14 / FASCIA / BLADE COMBINATIONS - CURTAIN WALL JANUARY, 217 STANDARD S STANDARD FASCIAS STANDARD BLADES 3" SQUARE RECTANGULAR INFINITY FLARE 36" SQUARE ARCH CIRCULAR 3" ROUNDED BULLNOSE AIRFOIL DIAMOND 36" ROUNDED PLANAR SQUARE WAVE 3" WEDGE ANGULAR CIRCULAR 36" WEDGE 3" CURVED CIRCULAR CIRCULAR SQUARE 36" CURVED DIAMOND
JANUARY, 217 / FASCIA / BLADE COMBINATIONS - CURTAIN WALL 15 INFINITY ARCH AIRFOIL 3" SQUARE PLANAR WAVE FLARE 36" SQUARE 3" ROUNDED CIRCULAR DIAMOND SQUARE INFINITY PLANAR ARCH WAVE AIRFOIL FLARE CIRCULAR DIAMOND SQUARE INFINITY PLANAR ARCH WAVE AIRFOIL FLARE CIRCULAR DIAMOND SQUARE INFINITY ARCH AIRFOIL 36" ROUNDED 3" CURVED PLANAR WAVE FLARE CIRCULAR DIAMOND SQUARE DIAMOND SQUARE CIRCULAR DIAMOND 3" WEDGE 36" WEDGE CIRCULAR CIRCULAR 36" CURVED SQUARE CIRCULAR
16 LOAD CHARTS - CURTAIN WALL JANUARY, 217 1 95 SPACING (METERS) 1. 2. 48 456 LOAD CHART EXAMPLE 16 Wall System TM 1 3" LOAD IN (PSF) 9 85 8 75 7 65 6 55 5 45 4 35 A 432 48 384 36 336 312 288 264 24 216 192 168 LOAD IN PASCALS (PA) Combined Load (Wind, Snow, Ice, etc.) = 65 PSF Outrigger Spacing = 5'-" Outrigger Projection = 3" Looking at the chart the following combinations are possible: 3" LONG WITH: A - CIRCULAR BLADE (4821) SQUARE BLADE (49411) DIAMOND BLADE (49411) C - ARCH BLADE (4946) D - FLARE BLADE (4948) E - WAVE BLADE (4941) F - INFINITY BLADE (4949) G - AIRFOIL BLADE (4945) 3 G 144 25 F 12 2 15 1 5 1 2 3 4 5 6 7 8 SPACING (FT) SPACING (OS) CENTER LINE TO CENTER LINE OF MULLIONS = SPACING (OS) +.938" LOAD IS A COMBINATION OF ALL APPLIED LOADS, SUCH AS WIND, SNOW, ICE, ETC. ACTING PERPENDICULAR TO THE BLADE. CHARTS HAVE BEEN ADJUSTED TO ACCOUNT FOR THE DEAD LOAD OF THE BLADES AND. E D C B 96 72 48 24 A - 3" with CIRCULAR BLADE 4821 or SQUARE / DIAMOND BLADE 49411 B - PLANAR BLADE 4947 C - ARCH BLADE 4946 D - FLARE BLADE 4948 E - WAVE BLADE 4941 F - INFINITY BLADE 4949 G - AIRFOIL BLADE 4945 CURVE NOTES: LINES BECOME DASHED WHERE SPECIFIC BLADES LIMIT LOAD CAPACITY. ALLOWABLE DEFLECTION IS BASED ON L/12. CURVES SHOWN REPRESENT THE ALLOWABLE LOADING AT BOTH INTERMEDIATE AND CORNER CONDITIONS.
JANUARY, 217 1 SPACING (METERS) 1. 2. 48 1 LOAD CHARTS - CURTAIN WALL 16 Wall System TM 1, 16 Wall System TM 2, 16UT System TM 1 (With 1-3/4" Triple Glazed Infill) 16 SS, 16 SS SSG and 163 SS IR (With 1-5/16" Double Glazed Infill) 3" 36" SPACING (METERS) 1. 2. 48 17 LOAD IN (PSF) 95 9 85 8 75 7 65 6 55 5 45 4 A 456 432 48 384 36 336 312 288 264 24 216 192 LOAD IN PASCALS (PA) LOAD IN (PSF) 95 9 85 8 75 7 65 6 55 5 45 4 456 432 48 384 36 336 312 288 264 24 216 192 LOAD IN PASCALS (PA) 35 168 35 A 168 3 G 144 3 G 144 25 F 12 25 F 12 2 15 1 5 1 2 3 4 5 6 7 8 SPACING (FT) SPACING (OS) E D C B 96 72 48 24 CENTER LINE TO CENTER LINE OF MULLIONS = (OS) +.938" (16 System TM 1, 16 SS, 16UT System TM 1 and 163 SS IR) (OS) + 1.62" (16 System TM 2, 16 SS SSG) LOAD IS A COMBINATION OF ALL APPLIED LOADS, SUCH AS WIND, SNOW, ICE, ETC. ACTING PERPENDICULAR TO THE BLADE. CHARTS HAVE BEEN ADJUSTED TO ACCOUNT FOR THE DEAD LOAD OF THE BLADES AND. 2 15 1 5 1 2 3 4 5 6 7 8 SPACING (FT) A - 3" or 36" with CIRCULAR BLADE 4821 or SQUARE / DIAMOND BLADE 49411 B - PLANAR BLADE 4947 C - ARCH BLADE 4946 D - FLARE BLADE 4948 E - WAVE BLADE 4941 F - INFINITY BLADE 4949 G - AIRFOIL BLADE 4945 E D C B 96 72 48 24 CURVE NOTES: LINES BECOME DASHED WHERE SPECIFIC BLADES LIMIT LOAD CAPACITY. ALLOWABLE DEFLECTION IS BASED ON L/12. CURVES SHOWN REPRESENT THE ALLOWABLE LOADING AT BOTH INTERMEDIATE AND CORNER CONDITIONS.
18 LOAD CHARTS - CURTAIN WALL 16 Wall System TM 5 and 16UT System TM 1 (With 1" Double Glazed Infill) JANUARY, 217 1 3" 36" SPACING SPACING (METERS) (METERS) 1. 2. 1. 2. 48 1 48 LOAD IN (PSF) 95 9 85 8 75 7 65 6 55 5 45 4 456 432 48 384 36 336 312 288 264 24 216 192 LOAD IN PASCALS (PA) LOAD IN (PSF) 95 9 85 8 75 7 65 6 55 5 45 4 456 432 48 384 36 336 312 288 264 24 216 192 LOAD IN PASCALS (PA) 35 A 168 35 168 3 G 144 3 144 25 F 12 25 A 12 2 15 1 5 1 2 3 4 5 6 7 8 SPACING (FT) SPACING (OS) CENTER LINE TO CENTER LINE OF MULLIONS = (OS) +.938" (16 System TM 5, 16UT System TM 1) E D C B 96 72 48 24 LOAD IS A COMBINATION OF ALL APPLIED LOADS, SUCH AS WIND, SNOW, ICE, ETC. ACTING PERPENDICULAR TO THE BLADE. CHARTS HAVE BEEN ADJUSTED TO ACCOUNT FOR THE DEAD LOAD OF THE BLADES AND. 2 15 1 5 1 2 3 4 5 6 7 8 SPACING (FT) A - 3" or 36" with CIRCULAR BLADE 4821 or SQUARE / DIAMOND BLADE 49411 B - PLANAR BLADE 4947 C - ARCH BLADE 4946 D - FLARE BLADE 4948 E - WAVE BLADE 4941 F - INFINITY BLADE 4949 G - AIRFOIL BLADE 4945 CURVE NOTES: LINES BECOME DASHED WHERE SPECIFIC BLADES LIMIT LOAD CAPACITY. ALLOWABLE DEFLECTION IS BASED ON L/12. CURVES SHOWN REPRESENT THE ALLOWABLE LOADING AT BOTH INTERMEDIATE AND CORNER CONDITIONS. E D C B 96 72 48 24