Operating Instructions

Similar documents
Operating Instructions

FORM (Apr. 2006)

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

Thomas Scientific Swedesboro, NJ U.S.A.

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

Globe Slicer Safety Tips

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

Instructions. Fibrlok TM 2670 Multi-Fiber Ribbon Construction Tool. November, B

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

SERVICE MANUAL- M126

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

CIRRUS AIRPLANE MAINTENANCE MANUAL

Symmetry Surgica l QUAD-LOCK Sterilization Container System

Corning Aspirator Instruction Manual

TECHNICAL INFORMATION Primer Residue Collection Kit for SEM, ICP-MS and AAA Catalog No. GRA100

FORM Rev. A (Feb. 2004)

FagronLab FG. Semi-automatic capsule filling machine. User Manual

INSTALLATION INSTRUCTIONS FOR BALCO, INC. FLOOR MATS FM2R-(A, C, D) W/O FRAME 4V

CIRRUS AIRPLANE MAINTENANCE MANUAL MODELS SR22 AND SR22T CHAPTER 56-20: CABIN GENERAL. Cabin 56-20: CABIN. 1. General

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

Laboratory Safety. A practical approach.

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Ceramic Probe Replacement Instructions Accessory G

TERMINAL BLOCK MARKERS MG CPM

Thermostatic Griddle Field Service Kit Instructions

Bard. BI-DIRECTIONAL and KELLY-WICK TUNNELERS. Instructions For Use. PK Rev. 1 04/06

Honda Ridgeline Installation Instructions

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

Advantage Plus TIM-3600 Series Reel

* * KR54-F, KR9854 & KR9954 Installation Instructions. Read All Warnings Before Starting Installation! Index:

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

Urea/Adblue Hose Reel

4A1-114/114KR & 4A1-2 MANUAL TENSIONERS

BGI, INC. WALTHAM, MA 02451

This protocol is designed for the isolation of 96 plasmid DNA samples from 1.3ml bacterial cultures. Yield is up to 6µg.

MODEL # 1 MANUAL CAN OPENER

Upchurch LOW PRESSURE FITTINGS AND CONNECTORS

1 Pan - 6 Ways to Cook! Works in the Oven & On All Stovetops! electric gas ceramic induction. Broil Bake Sauté Fry Steam Braise

Accu-Chart TM Healthcare Systems, Inc.

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

IMPORTANT NOTICE. Professional Mandoline Manual

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

Interpretation Guide. Coliform Count Plate

2522 and 2523 Fiber Optic Splice Organizer Tray

42-YP Series. Serie 42-YP Série 42-YP. Single Control Lavatory Faucet Grifo Monomando para el Baño Mitigeur de Robinet pour Lavabo

INSTALLATION INSTRUCTIONS for automatic awnings

ipad mini 4 LTE Home Button Assembly Replacement

Big SHOT III Hybridization Oven

NNIN Nanotechnology Education

Kontrol Kube Advanced Owners Manual

Pediatric Lower Body Warming Blanket Model B203 Instructions for Use

Made of polypropylene

Making Solar Cells 1 from Household Materials (mostly :)

S E L E C T I O N. Abdominal Crunch. User manual

One Piece Low Torque Kelly Valve. Preventive Maintenance Service Video Disassembly and Assembly Procedures

Replacement of External Pipe Assembly on PFS December 21, 2014

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

3. SS 4. SS 5. SS 6. SS

ipad mini 4 Wi-Fi Volume Control Buttons Replacement

RAFTER VI. Installation and Operation CAREFREE WITH AUTOMATIC AWNING SUPPORT. RV Accessory PRODUCT OVERVIEW

Two Piece Low Torque Kelly Valve

TASK FORCE TIPS * *

Professional Mandoline Manual. Model: 90797

Professional Mandoline Manual. Model: 90757

Productivity. Technician. Maximized. Interpretation Guide

Installation and Maintenance Manual

StratoLauncher IV Standard Instruction Manual

31 Series. Serie 31 Série 31. Two Handle Kitchen Faucet Grifo Con Dos Manijas Para Cocina Robinet De Cuisine À Avec Deux Poignées COMPANY

Glass Door Fittings Glass Door Accessories

functionality with the necessary maintenance tools stored in a convenient built in tool box, as well as parallel handles for

Gosford Aquifier (Pre 2009) Replace O-rings here

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation

14' x 32' x 12' Round Top Round Style Shelter Assembly Instructions

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS C3215/C3215A

Operating Instructions

WARMING BLANKETS INSTRUCTIONS FOR USE

A Pre-Paid Return Label is included (optional) *Call for pick up no later than the above return date to avoid additional rental fees

Interpretation Guide

Interpretation Guide

--- BIG LEAGUE BATTING CAGE ---

300 Model 870 Four Wheel Hose Cart Owner s Manual

Sterilization Containers. Customized solutions for value-preserving instrument reprocessing

ipad mini 4 Wi-Fi Display Assembly Replacement

Required Tools: Phillips screw driver to remove original soft top. Torx sockets are required to completely remove the original soft top hardware.

9 LABORATORY ACCESSORY

International Scout 80/800

SIMPLIFIED TECHNIQUE FOR THE COLLECTION OF RABIES DIAGNOSTIC MATERIAL FROM ANIMALS

Solera Classic Awning OEM INSTALLATION MANUAL

WHAT TO KNOW BEFORE INSTALLING...

Sunjoy D-DNC492PST 3-Seat Striped Adjustable Tilt Canopy. Wicker Metal Swing. Owner s Manual IMPORTANT

STERILE CONTAINER SYSTEMS

LODGE 460 CABIN. Part No ASSEMBLY & CARE INSTRUCTIONS

INSTALL INSTRUCTIONS for VEHICLES

VALORE SEVEN. Serial Number. Pacific) Version No.:V

ADDED PROTECTION FOR SLIDE-OUT ROOMS. Installation. Introduction... 2 Product Overview...2 Component Checklist...3

Innovative New Products

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles


Transcription:

Operating Instructions High Throughput Dialysis MODEL HTD96b www.htdialysis.com

HTD96b : Operating Instructions Components Universal Base Unit Teflon block assembly: 9 Teflon bars, labeled sequentially from A through I, are assembled with two stainless steel connecting rods. Cam Cam Levers Pressure Plate Clamp In Closed Position Place Stainless Steel Pressure Plate in Base Slot when unit is not in use Clamp In Open Position 1

Cleaning the Teflon bars 1 Open the clamp by rotating the cam levers 45 degrees. To ensure even pressure, always use 2 hands to operate the clamp. 2 Remove the entire Teflon block assembly from the clamp, then remove the stainless pressure plate. 3 Remove one or two Teflon bars from one end of the assembly, then pull out both stainless steel connecting rods. (Teflon bars will disassemble.) 4 Clean separated Teflon bars with nonionic laboratory detergent. Note: Always rinse away all detergent residue with distilled water before re-use. 2

Hydrating the Dialysis Membranes Each dry membrane strip consists of a pair of dialysis membranes that separate upon hydration. Hydrate the dialysis membranes by soaking in distilled H 2 O or phosphate buffered saline (PBS) for 60 minutes. Add 20% by volume ethanol and soak for a further 20 minutes. Membranes are ready for use or may be left in the 20% ethanol for extended storage. Prior to use membranes must be rinsed twice in distilled H 2 O or PBS. Make sure only a single sheet of dialysis membrane is placed between Teflon bars. Wipe off excessive buffer from the membrane. Flatten membrane before the next Teflon bar is put in place. Assembling the Teflon Bars with Dialysis Membrane 1 Lay the first Teflon bar (labeled A) flat on the bench (see picture), insert the two stainless steel connecting rods so they are perpendicular to the Teflon bar. 2 Place the membrane on the Teflon bar. Ensure that the membrane is approximately 2mm below the top edge of the bar and the lower membrane edge overlaps the bottom of all wells. 2 mm 3 Repeat layering dialysis membranes and Teflon bars until the unit is fully assembled (assemble Teflon bars in alphabetical order). Teflon Bar Membrane Note: Although the number of membranes inserted can be varied to suit the experimental requirements, all the Teflon bars must be assembled before loading the Teflon block into the base. 3

Loading the Teflon Block into the Base 1 Make sure the clamp is in the open position before loading the Teflon block into the base. 1 2 Insert the Teflon block into the base, then place the stainless steel pressure plate between the Teflon block and the cam as shown. 2 3 Always tighten the assembled unit with even pressure by using both hands to rotate the cam levers. 3 Fully assembled unit Important Note: Immediately add buffer to the dialysate side of the wells to prevent dehydration of the membranes before the test samples are added. Unit is ready for use! 4

Loading Samples into Dialysis Wells Samples can be added to the dialysis wells using any standard 8- or 12-well multichannel pipetting device or 96-well pipetting instrument. Test samples are most conveniently prepared in 96-well tubes or plates, since this facilitates preparation of dilutions, replicate samples and mixing. Volumes of 25 to 150 µl can be used in this apparatus, however it is essential that equal volumes are used on each side of the membrane. Dialysis After loading, cover the top surface of the Teflon block with an adhesive sealing film (e.g., HTD adhesive sealing film Catalog #1102) to prevent evaporation and maintain a constant ph. The dialysis block can be incubated at any desired temperature. Equilibrium is reached more rapidly if the block is placed on an orbital or reciprocating shaker. Although most compounds reach equilibrium in about four hours, the standard protocol recommends six hours dialysis to ensure equilibrium conditions are achieved. Samples can be added or removed from the dialysis well at anytime during the experiment by merely removing the adhesive seal to gain access. Care and Storage of the HTD96b The HTD96b base and stainless steel pressure plate do not require routine washing and should merely be wiped clean with a paper towel. However, after each use, the Teflon block should be cleaned with a non-ionic laboratory detergent and rinsed thoroughly with distilled water. Care must be taken to ensure that all detergent has been rinsed from the Teflon block as residual detergent could compromise future binding studies. The Teflon block may also be disinfected with a 10% bleach solution if desired. It is essential to always store the stainless steel pressure plate in the base slot that is under the Teflon block to eliminate continual pressure on the Teflon block. Storing the HTD96b unit in the closed position with the pressure plate inserted in the clamp for extended periods may compress the Teflon and reduce the effectiveness of the base clamp. 5

Pressure Plate Maintenance Normal operation of the HTD96b does not require washing of the pressure plate assembly and therefore no scheduled maintenance is required. The two pressure plates are separated by disk springs that allow the application of sufficient force to prevent seepage or leakage between wells in the Teflon block. Although these disk springs are made of series 17 stainless steel, prolonged exposure to aqueous solvents or oxidizing cleaning agents may result in some rust. To minimize exposure to aqueous solvents the springs are coated with a silicone seal during factory assembly. If the experimental protocol uses radioisotopes or other hazardous reagents we recommend the following options: A B C Wrap the pressure plate assembly in a film of clear plastic wrap to isolate it from the liquids. Line the base with clear plastic wrap before inserting the Teflon block, thereby isolating the entire base from the Teflon block and all reagents. If it is necessary to wash the pressure plates, disassemble after every 25 uses, dry, coat with fresh silicone seal and reassemble. 6

Components Stainless steel disk springs replacement procedure to eliminate spring oxidation Philips screwdriver Stainless steel pressure plate assembly Twenty stainless steel disk springs 1 Disassemble the pressure plate assembly by removing five setscrews with a Phillips screwdriver. Cross Section View Plate 2 Plate 1 2 Remove stainless steel disk springs, dry and wipe clean, coat with an appropriate silicone sealant. Place the stainless steel disk springs in sequence as shown in Figure 1 (four disks each column) Figure 1 3 Reassemble pressure plate assembly by placing plate 2 over the disk springs and tightening the setscrews until the unit height is 0.46 everywhere. Figure 2 0.46 Figure 2 7

2014 HTDialysis LLC www.htdialysis.com Version 3.0