SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE

Similar documents
SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF

SUBMITTAL DATA SHEET COOLING PERFORMANCE HEATING PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE ELECTRICAL DATA TOTAL UNIT WEIGHT

ELITE SERIES R-410A Ready - Multi-Position

ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants

Job Name: Tag# 4 Port, 3-Ton Outdoor Heat Pump

SUBMITTAL DATA SHEET. SPLIT-SYSTEM AIR CONDITIONING CONDENSING UNITS TONS MODELS: YC090 thru 300, 2-PIPE YD120 thru 240, 4-PIPE FEATURES

MODEL CFD Forward Curved Belt Driven Inline Duct Blower

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW

EDM4X, EDM2X. Product Specifications EXPANSION VALVE COILS ALL MODELS

GRAVITY VENTILATORS SIZING

Industry best 5 year fan housing warranty, 1 year motor warranty

Crusader Training updated 11/1/16

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL

VFR Parallel Flow, Fan-Powered, VAV Terminals

Toyostove Error Code EE 2 (EE 6)

1.1 F.D.N.Y. Designation Inflatable Soft Landing Mat. 1.5 Weight Landing Mat...80 lbs. Blower Unit...80 lbs. Figure 1

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

CADDY CORPORATION. Hot Food Caddys

Capacity 24 bottles Six shelves cradle bottles horizontally to keep corks moist o Shelves are coated to reduce vibration

DUWC1441 Designer. cabinet, and black interior.

Frequently Asked Questions

Nexus Standard Glove Box System

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

REFRIGERATION. Standard Features & Accessories. Model Options. Undercounter/Freestanding 24 W. Dual Zone Wine Cellar

Crusader Training. updated 11/1/17

REFRIGERATION. Standard Features & Accessories. Model Options. Undercounter/Freestanding 24 W. Wine Cellar

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

PRD366JGU 36-INCH DUAL-FUEL PRO GRAND RANGE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRD486WDHU 48-INCH DUAL-FUEL PRO HARMONY RANGE WITH GRIDDLE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE RANGETOP

PRG366WH 36-INCH GAS PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE RANGETOP

Emergency Stop Devices

PRG366JG 36-INCH GAS PRO GRAND RANGE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRL364NLH 36-INCH GAS PRO HARMONY RANGE WITH GRILL (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

PARTS LIST CHARGER 2022 ABLT

Installation Instructions

DP13GM DP15GM. Multi-position Installation. Comfort for Life

PRL364NLG 36-INCH GAS PRO GRAND RANGE WITH GRILL (LP) PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

DF 6.5 thru 10.0 Ton. Mid Efficiency

WARNING. Effective Date: 1-03

Electronic Temperature Controls

PRL486JDG 48-INCH GAS PRO GRAND RANGE WITH GRIDDLE (LP) PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRD366GHU 36-INCH DUAL-FUEL PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

ELEVATION MODELS Elevation models weigh up to 20% less than every other Toy-Hauler in their class!

Filter Oil 8-HD. Lower cookpot lid. Be careful not to pinch fingers between lock and roller or lock and frame.

Undercounter/Freestanding 15 W. Wine Cellar

ELEVATION MODELS Elevation models weigh up to 20% less than every other Toy-Hauler in their class!

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

PARTS MANUAL Gas Furnace F9MVT, G9MVT

Blue Series Hot Melt Hose with RediFlext II Hanger System

Installation instruction

DUPLEX STRAINERS 800-KECKLEY ( ) BULLETIN NO / FAX: 847/ WEB SITE:

Installation Instructions

it takes you back to the good old days of grandpa s childhood.

PARTS MANUAL Gas Furnace F9MXT, G9MXT

EXPLOSIONADO DE PARTES

Revolutionary. Benefits

The four elements of nature: Fire, Water Earth & Air

Start Living on Mountain Time

Installation Instructions

PBG PACKAGED GAS BURNERS

micro combustion chamber Mega vision of the flames precision control of combustion air, the control operates five air channels

Product information Truma VarioHeat and E-Kit. July 2018

Piranha Ironworkers All Share These Standard Features

INSTALLATION INSTRUCTIONS

ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O

13 Seer Package Gas Electric Unit 2 To 5 Tons

FILTERED FAN PACKAGES

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

MD5501Y pies Acero Monocromatico. Capacidad Color. Gabinete. Whirlpool Mexico S.A de C.V. 1/24 JAS

ROOF CURBS. Prefabricated Curbs. Moving Your Way BULLETIN RC15 TABLE OF CONTENTS

OIL BURNING STOVE EVEREST

You recognize it immediately. The shape, the name, the quality. The Harman. P-Series gives you the heat you want when you want it.

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

AFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Pneumatic tents and showers. Immediately ready to use and extensively equipped.

TM COMPRESSOR, ROTARY: AIR DIESEL ENGINE DRIVEN; 250 CFM ORGANIZATIONAL, DS, GS, AND DEPOT MAINTENANCE MANUAL

MINI-RAPTOR VAC PACKS

DUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076

DEMV-MF2 DEP-MFP. Horizontal Lathes. Heavy Duty Machines

A reliable deck oven that works for both confectionary and bakeries.

NEW NEW FLOORPLANS! CRUSADER 319RKT 340RST CRUSADER LITE 26RE

CESSNA SKYMASTER 337

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

FLOORPLANS ZR-18BH ZR-18RB ZR-18SS W. Lake St Topeka, IN (260)

Installation Instructions

Reiff Manufaturing. Shelter Types. Airport Landing System Equipment Shelters. Maintenance Shelters. Cellular Phone Shelters

Installation Instructions

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Prefabricated Curbs for Roof Mounted Ventilation Equipment, R-Series

REPAIR PARTS. CLJ Remote 12 SEER Condensing Units

Installation Instructions

Supersedes: AD3V (991) AD3V (1294)

Model Number Structure

CONTENTS 1. 1 Curtain Transvectors Overview Features Benefits Applications Uses... 3

VAC N BLO CAR VAC COMMERCIAL SERIES

Transcription:

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP078-150 JOB NAME: PURCHASER: LOCATION: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. MODEL NO. COOLING PERFORMANCE TOTAL CAPACITY- - - - - - - - - - - - - - MBH SENSIBLE CAPACITY - - - - - - - - - - - MBH OUTDOOR DESIGN TMP. - F DB/WB TOTAL SUPPLY AIR - - - - - - - - - - - - CFM TEMP. OF AIR ENTERING EVAPORATOR COIL - - - - - - - - - - - - - - F POWER INPUT REQ. - - - - - - - - - - - - - KW (LESS BLOWER MOTOR) HEATING PERFORMANCE CAPACITY @ 47 F- - - - - - - - - - - - - - - MBH @ 17 F- - - - - - - - - - - - - - - MBH COEFFICIENT OF PERFORMANCE @ 47 F- - - - - - - - - - - - - - - MBH @ 17 F- - - - - - - - - - - - - - - MBH ELECTRIC HEAT - - - - - - - - - - - - - - - - KW SUPPLY AIR BLOWER PERFORMANCE TOTAL SUPPLY AIR - - - - - - - - - - - - CFM EXT. STATIC PRESS. - - - - - - - - - - - - IWG BLOWER SPEED- - - - - - - - - - - - - - - - RPM POWER OUTPUT REQ. - - - - - - - - - - BHP MOTOR RATING - - - - - - - - - - - - - - - - - HP POWER INPUT REQ. - - - - - - - - - - - - - KW ELECTRICAL DATA POWER SUPPLY- - - - - - - - - - - - - - - TOTAL UNIT AMPACITY - - - - - - - - AMPS MAX. OVERCURRENT DEVICE FUSE BREAKER - - - - - - - - - AMPS TOTAL UNIT WEIGHT INCLUDING FACTORY- INSTALLED OPTIONS - - - - - - - - - - - - - - - - - - - - - LBS Unitary Products Group 267729-YSD-C-0212

6.5 to 12.5 Ton See detail A for drain location 12.5 Ton See detail A for drain location 6.5 to 12.5 Ton Unit Physical Dimensions Unit Model Number Dimension (in.) A B C D E F XP078 42 89 22 1/8 18 3/16 15 3/16 6 3/16 XP090 42 89 22 1/8 18 3/16 15 3/16 6 3/16 XP102 50 3/4 89 30 3/16 24 3/16 17 3/16 6 3/16 XP120 50 3/4 89 30 3/16 24 3/16 17 3/16 6 3/16 XP150 50 3/4 119 1/2 30 3/16 24 3/16 17 3/16 6 3/16 2 Unitary Products Group

Detail A 5-3/8 6.5 to 12.5 Ton Unit Side Duct Openings D o t P l u g s 1 8-1 /4 S u p p l y A i r R e tu r n A i r A D B 5-5 /3 2 C 2-3 1 /3 2 3 1-1 1 /1 6 12.5 Ton Unit Side Duct Openings Dot Plugs 18-1/4 A D B 5-5/32 C 31-5/8 2-7/8 Unitary Products Group 3

6.5 to 12.5 Ton Side Duct Dimensions Unit Model Number Dimension (in.) A B C D XP078 27 3/4 12 1/16 27 1/2 16 XP090 27 3/4 12 1/16 27 1/2 16 XP102 28 1/4 18 1/16 28 1/4 18 1/4 XP120 28 1/4 18 1/16 28 1/4 18 1/4 XP150 28 1/4 18 1/16 28 1/4 18 1/4 6.5 to 12.5 Ton Unit Clearances Direction Distance (in.) Direction Distance (in.) Top 1 72 Right 12 Front 36 Left 36 Rear 36 Bottom 2 0 1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air discharge outlet. 2. Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. 6.5 to 12.5 Ton Unit Bottom Duct Openings 4 Unitary Products Group

6.5 to 12.5 Ton Unit Electrical Entry Disconnect Swith Cover Power Entry Ø 2-1/2 Control Entry Ø 7/8 Power Entry Ø 2-1/2 Convenience Outlet Cover Convenience Outlet Power Entry Ø 7/8 FRONT 6.5 to 12.5 Ton Unit Left Duct Opening 30-3/8 4-5/16 Unitary Products Group 5

6.5 to 12.5 Ton Unit Roof Curb RIGHT 80-5/8 INSULATED DECK UNDER CONDENSER SECTION 20 20 6 SUPPLY 2TYP. RETURN 30 50-1/2 INSULATED DECK UNDER COMPRESSOR SECTION 8 or 14 FRONT 6.5 to 12.5 Ton Unit Transition Roof Curb 2TYP 50-1/2 30-1/2 23 4 RETURN SUPPLY 26 80-5/8 10 76-5/8 FRONT 94 59-1/4 64-1/4 RIGHT 6 Unitary Products Group

6.5 to 12.5 Ton Unit Economizer Assembly 58 1/4 88 1/4 39 1/2 or 47 1/2 Outside Air Intake Hood 35 3/4 Relief Hood for Power Exhaust or Barometric Relief 26 25 3/4 26 30 1/4 Unitary Products Group 7

FACTORY INSTALLED OPTIONS ELECTRIC HEATER MODEL - KW VOLTS STAINLESS STEEL DRAIN PAN- - - - - - - - - - - - - - - - - ECONOMIZER, DOWNFLOW - - - - - - - - - - - - - - - - - - - ECONOMIZER, HORIZONTAL - - - - - - - - - - - - - - - - - - ECONOMIZER, SLAB - - - - - - - - - - - - - - - - - - - - - - - - POWER EXHAUST - - - - - - - - - - - - - - - - - - - - - - - - - - MOTORIZED AIR DAMPER - - - - - - - - - - - - - - - - - - - - HIGH STATIC INDOOR BLOWER MOTOR - - - - - - - - - DISCONNECT SWITCH - - - - - - - - - - - - - - - - - - - - - - - CONVENIENCE OUTLET, POWERED - - - - - - - - - - - - CONVENIENCE OUTLET, NON-POWERED - - - - - - - - SMOKE DETECTOR (RETURN) - - - - - - - - - - - - - - - - - SMOKE DETECTOR (SUPPLY) - - - - - - - - - - - - - - - - - PHASE MONITOR 1 - - - - - - - - - - - - - - - - - - - - - - - - - - COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - DIRTY FILTER SWITCH - - - - - - - - - - - - - - - - - - - - - - - FILTERS, 2" PLEATED, MERV 7 - - - - - - - - - - - - - - - - FILTERS, 4" PLEATED, MERV 13 - - - - - - - - - - - - - - - PHENOLIC COATED EVAPORATOR COILS - - - - - - - - PHENOLIC COATED CONDENSER COILS - - - - - - - - - ELECTROFIN EVAPORATOR COILS - - - - - - - - - - - - ELECTROFIN CONDENSER COILS - - - - - - - - - - - - - BAS OPTION Simplicity Intelli-Comfort II - - - - - - - - - - - - - - - - - Honeywell - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Novar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Johnson - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CPC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FIELD INSTALLED ACCESSORIES ROOF CURB, 8"- - - - - - - - - - - - - - - - - - - - - - - - - - - - - ROOF CURB, 14"- - - - - - - - - - - - - - - - - - - - - - - - - - - - TRANSITION ROOF CURB- - - - - - - - - - - - - - - - - - - - - COIL GUARD- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HAIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PERMANENT FILTERS - - - - - - - - - - - - - - - - - - - - - - - METAL FILTER FRAME KIT - - - - - - - - - - - - - - - - - - - - DIRTY FILTER SWITCH - - - - - - - - - - - - - - - - - - - - - - - AIR PROVING SWITCH - - - - - - - - - - - - - - - - - - - - - - - BURGLAR BARS (DOWNFLOW ONLY)- - - - - - - - - - - - LOW AMBIENT KIT - - - - - - - - - - - - - - - - - - - - - - - - - - SMOKE DETECTOR (RETURN) - - - - - - - - - - - - - - - - - SMOKE DETECTOR (SUPPLY) - - - - - - - - - - - - - - - - - CO2 SENSOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PHASE MONITOR 1 - - - - - - - - - - - - - - - - - - - - - - - - - - ECONOMIZER, DOWNFLOW - - - - - - - - - - - - - - - - - - - ECONOMIZER, HORIZONTAL - - - - - - - - - - - - - - - - - - ECONOMIZER, SLAB- - - - - - - - - - - - - - - - - - - - - - - - - DUAL ENTHALPY - - - - - - - - - - - - - - - - - - - - - - - - - - - POWER EXHAUST - - - - - - - - - - - - - - - - - - - - - - - - - - MOTORIZED OUTDOOR AIR DAMPER - - - - - - - - - - - MANUAL OUTDOOR AIR DAMPER - - - - - - - - - - - - - - ELECTRIC HEATER MODEL - KW VOLTS WALL MOUNT TEMPERATURE SENSOR (Intelli-Comfort II ) - - - - - - - - - - - - - - - - - - - - - - - - - - WALL MOUNT TEMPERATURE SENSOR WITH OVERRIDE (Intelli-Comfort II ) - - - - - - - - - - - - - - - - - WALL MOUNT TEMPERATURE SENSOR WITH OVERRIDE & SET POINT ADJ. (Intelli-Comfort II )- - - - HUMIDITY SENSOR (Intelli-Comfort II ) - - - - - - - - - - - 1. Phase monitor standard on units with scroll compressors. Subject to change without notice. Printed in U.S.A. Copyright 2012 by Johnson Controls, Inc. All rights reserved. 267729-YSD-C-0212 Supersedes: 267729-YSD-B-0511 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069