Foam Systems Engineering Design Manual

Similar documents
Firefighting Group Foam Systems. 1. Foam Pourer 2. Foam Makers 3. High Back Pressure 4. Bladder Tanks 5. Foam Porportioner 6.

8" 9000, " x 25" How to Specify NH-24

Hammer, Discus, Shot Put, Javelin

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

HANDWHEELS.

DUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076

Clay & Bailey Mfg. Co.

PN 3000 Series Fail Closed Pneumatic Actuators

FOAM PROPORTIONING EQUIPMENT

AMS MU800 Mullion Drained Curtain Walling

Shallow IC of 5

Couplings for Gates Hoses 7 Combination Nipple

DUPLEX STRAINERS 800-KECKLEY ( ) BULLETIN NO / FAX: 847/ WEB SITE:

ADVANCE PRODUCTS & SYSTEMS, INC. FOR FLANGES, VALVES & EXPANSION JOINTS SAFETY SPRAY SHIELDS CONTAINS AND DETECTS HAZARDOUS SPRAYOUTS

Flying Banners. Shape & Size. Material & Pole Sleeve. Mounting Accessories PROJECTING SIGNS & FLAGS

HANDLES, LE VERS & CR ANKS

Introduction TEFLON PFA Filtration

OW LEE CASUAL FIRESIDE Q&A

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

For draining expansion tanks, other liquid storage vessels.

The tried-and-tested complete range

Eclipse Hermetic Gas Boosters Series HB

style vision & quarter turns quarter turns section section INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS

SS SERIES STAINLESS STEEL SLIDE GATE

CBO-750 ASSEMBLY INSTRUCTIONS

The safe & affordable install

A EURO-QUALIFLEX (AEQ) MEMBER. Publish date Rev. No: 01

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

Awnings ISSUE: AW Sec. : Awnings Date : Aug 2015

WEXEL BUILDING PRODUCTS. Roof Outlets. and. Floor Drains

Flexible flue liner components Specifications

Reverse Osmosis system 50 GPD Instruction manual EN

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

Bathroom. Toilet Aids. Folding Commode/Over Toilet Aid. Over Toilet Aid. Aspire Over Toilet Aid. Aluminium Over Toilet Aid

OW LEE CASUAL FIRESIDE Q&A

Ground Clamps Cable Tray

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

Swagelok Thermoplastic Hose Hand Swager User s Manual

Read all instructions and warnings before using this fireplace. WARNING

Assembly Instructions: Square Tile Fire Pit With Embossed Side Panels

Virto - the flexibility of a natural shape.

Stainless Steel Combined Drinking Fountain With Bottle Filler

Beds and Related Equipment for HSP

OWNER S MANUAL 10x10 SUN SHELTER WITH NETTING

4 Storage cupboards SCALA

SKU Product Name Price American Underslung

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information

ATHLETICS High Jump & Pole Vault

Hammer, Discus, Shot Put, Javelin

Design Standards. Utility Manhole Covers

Professional Promotion Solutions

Section 11 Workstation Components

Design Standard. Utility Manhole Covers

T&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings

MMSlog MULTIFUNCTIONAL TROLLEY

JD Burford Limited Unit 2D Hirwaun Industrial Estate Aberdare, South Wales, UK, CF44 9UP

EXPANDING 07BARRIERS

Model SBS-10. Stainless Steel Simplex Basket Strainer. 21 Columbus Avenue Garfield, NJ 07026

2015/16 PROTECTING THE TOOLS OF YOUR LIVELIHOOD

TIMBER BOLLARDS TYPE I. TYPE ll TS mm Radius 150 x 100 white painted Timber post dia Timber Post. Ground Level NOTES:

SECTION I-1. Type: 1812-AC. Fuel: Air-Gas.

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).

MODELS: 440 SM & 440 SMSS

! NO ROPES, PULLEYS OR ZIPPERS! ROBUST GEARBOX OPERATION! EXTRA FIXING POINTS CAN BE FITTED TO ! O PTIONAL HEADBOX

Emergency Stop Devices

SIN GLE BOND HOSE CLAMPS

NORMACLAMP COBRA. One-piece hose clips. Advantages at a glance. Applications

SECTIONAL OVERHEAD DOORS


Enhanced Emergency Shelter Kit (EESK)

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

CUSTOM CYLINDERS INTERNATIONAL, INC. SOCKET JENIE PRODUCTS

HARVIA IRON STOVE Instructions for installation and use

Table and Furniture Base Fittings Furniture Feets

Page 92

EMERGENCY EYE WASH EMERGENCY SHOWER INDUSTRIAL & LABORATORY SAFETY EQUIPMENT

Primrose Awnings Half Cassette Manual & Electric Instructions

TEMPEST. giant heavy-duty commercial umbrella. premium outdoor living

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

WARDROBE FITTINGS Wardrobe Accessories P Clothes Hanger Accessories P Hangers & Shoe Racks P.

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Aluminum HC Full Contact Type Internal Floating Roofs Technical Specifications

Technical data. Patio awnings. 550 Cassette Folding Arm Awning

PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS

Manufacture of fire fighting equipments and plumbing items

E13.11 SPRING CATCHES E13 BOTTOM HUNG OPEN IN WINDOWS

Primrose Awnings Full Cassette Manual & Electric Instructions

Aluminum Internal Floating Roofs Perimeter Seal Systems Oil / Water Separator Covers For API Separator Basins SUPERIOR SYSTEMS, UNSURPASSED SERVICE

Primrose Awnings Half Cassette Manual & Electric Instructions

Sigma. Did you know? Do you need? x Diameter. Pellet

Installation Instructions for. Thrifty King CT Series Fountains

Hose Clamps & Fittings

Installation & User Manual EW5000 Outdoor Cooking Fire

J1000. Supreme MEADRAIN. Material: Polymer concrete

CABLE GRIPS CABLE GRIPS

Friction and knife shafts

A A A T E C H N O L O G Y

APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE

The Shand & Jurs Model Pressure Relief Vent

Cassette-folding arm-awning markilux 990

Transcription:

Foam Systems Engineering Design Manual

CONTENTS Foam Systems Engineering Design Manual Haardous Chemical & Product Data 1 Foam Concentrate Induction Systems 2 Protection of Fuel Storage Tanks 3 Foam Base Injection 4 Oil & Chemical Carriers, Jetties & Docks 5 High & Medium Expansion Foam Systems 6 Foam Sprinkler Systems 7 Aircraft Hangars & Helicopter Landing Areas 8 4023-2-17 ENGINEERING MANUAL CONTENTS

S E C T I O N T H R E E Protection of Fuel Storage Tanks Introduction Section 3.1 Page 3.3 Base Injection Section 3.2 Page 3.7 Foam Top Pouring Systems Fixed Roof Tanks Section 3.3 Page 3.8 Rimseal Pouring Systems Floating Roof Tanks Section 3.4 Page 3.16 Bund (Dike) Area Protection Section 3.5 Page 3.22 Foam Monitors Section 3.6 Page 3.28 Supplementary Protection Section 3.7 Page 3.31 Exposure Protection Section 3.8 Page 3.33 4023-2-17 ENGINEERING MANUAL SECTION THREE PAGE 3. 1

3.4 RIMSEAL POURING SYSTEMS FLOATING ROOF TANKS For the purposes of this Section, Open Top Floating Roof (OTFR) Tanks are defined as being vertical tanks without a permanently installed fixed roof, but with a closed double-deck or pontoon type floating roof. Two basic types of seal around the rim of the floating roof exist: i) Mechanical shoe seal or Pantograph seal. ii) Tube seal. Weathershields and secondary seals of combustible or noncombustible materials may also be installed. NOTE: Rimseal Protection is not suitable for floating roofs where the roof is: The initial haard area on an OTFR tank is identified as the area in the annular ring between the rim of the floating roof and the tank shell. There are two commonly used methods of protection: i) The discharge of aspirated foam above the mechanical or tube seal, weathershield or secondary seal. ii) The discharge of aspirated foam either below a mechanical or tube seal directly onto the burning fuel surface, or below a weathershield or secondary seal but directly above the primary mechanical or tube seal area. Angus Fire recommends that option (i) should be adopted wherever possible and the following information is based upon this preferred method. A plastic blanket or floating diaphragm. Based on floatation materials which are flammable (eg. Plastic, Styrofoam). Reliant on floatation devices easily submerged if damaged. A pan roof. 700 300 600 FOAM SOLUTION FLOW (LITRES/MIN) 200 100 FOAM SOLUTION FLOW (LITRES/MIN) 500 400 300 200 100 4 6 8 10 12 INLET PRESSURE (BAR.G) 4 6 8 10 12 INLET PRESSURE (BAR.G) Graph 3.3 Angus RFG50 Performance Graph 3.3.1 Angus RFG 80 Performance PAGE 3. 16 4023-2-17 ENGINEERING MANUAL SECTION THREE

SPECIFICATION DATA RFG 50 RFG 80 RFP 50 RFP 80 Dimension A (mm) 159 236 - - B (mm) - - 1000 1000 C (mm) - - 700 700 D (mm) - - 200 240 E (mm) - - 40 40 F (mm) - - 75 75 G (mm) - - 142 102 H (mm) 75 AF Hex. 105 AF Hex. - - Inlet Connection 2 NPSC (f ) 3 NPSC (f ) 2 NPT (m) 3 NPT (m) 2 ANSI Available Outlet Connection 2 NPSC (f ) 3 NPSC (f ) - - Materials Body Cast Iron to BS 2789 Grade 420/12 - - Internal Fitting Stainless Steel to BS 970 316S31 - - Deflector - - Carbon Steel Internal Mesh - - Stainless Steel Pipe - - Steel tube to BS 1387 Optional Clamps - - Clamp: Malleable iron, natural finish Bolt: Steel, inc plated Finish Yellow Thermoplastic Powder Coat Approx. Weight (kg) 3.5 6.5 37 41 To Install Fixing Holes - - 4 x 12 mm dia. Holes Optional Clamps - - Min. 2 clamps per pourer OPERATING DATA Operating Pressure 4 bar to 10 bar Typical Foam Expansion 4:1 to 8:1 Typical 25% Drainage Time 1.5 to 3 minutes using Angus FP70 C6 Foam Concentrate Fig. 3.13 Angus RFG Rimseal Foam Generator & Pourer 4023-2-17 ENGINEERING MANUAL SECTION THREE PAGE 3. 17

3.4.1 Rimseal Foam Generators and Pourers Angus Fire rimseal foam equipment traditionally comprises two elements - the Rimseal Foam Generator (RFG) which aspirates the foam solution and the Rimseal Foam Pourer (RFP) which delivers the finished foam gently into the rimseal area. This configuration provides the best foam quality blanket and consequently the greatest likelihood of fast and effective extinction in the seal area. The design of the RFP ensures that a cohesive blanket is produced which is protected from the effects of high winds, is directed onto the tank shell so it flows in contact with the inside wall of the tank and into the seal area. The stainless steel mesh at the RFP foam exit helps to improve foam quality and prevent blockage from insects and nesting birds. RFGs are available in two basic body sies (50 & 80mm) with capacities ranging from 54 litres/min. at 4 bar to 684 litre/min. at 10 bar. Each unit is factory-calibrated to deliver a specified flow at a given inlet pressure within the limits shown in Graph 3.3, and easily attaches by a screw thread to the RFP. This will enable the system designer to make the most cost-effective use of the available foam concentrate and water resources. Rimseal foam systems do not protect a tank against a full surface fire. Although these are rare, some owners wish to protect against this eventuality either with a mobile system (see section 3.6) or a fixed system capable of delivering sufficient foam to extinguish a fire involving the entire tank surface. The Angus Full Surface Pourer (FSP) is designed to achieve this. On tanks over 100m in diameter it is possible that even the flow of foam from an FSP may not reach the centre of the tank. In this instance the FSP can be complemented with the Angus Full Surface Nole which projects foam into the central dead spot on the tank. Please contact Angus for further details on these products. Fig. 3.14 Typical RFG Installation on Storage Tank Full Surface Pourer Full Surface Nole 3.4.2 System Design Details To apply expanded finished foam effectively above the seal, a foam dam will be required to be fitted to the floating roof to retain the aspirated foam blanket within the seal area, and prevent it from flowing across the roof. By containing the foam in this way to a foam ring or annulus above the seal area, a sufficient foam depth will be achieved. It will also cause the foam to flow laterally around the seal perimeter between pourers, to a point where the seal may have been ruptured. The circular foam dam should therefore be constructed from suitable corrosion resistant materials and be at least 0.3m and more generally around 0.6m in height. There should also be a minimum width distance of at least 0.3m (but more generally 0.6m wide) between the edge of the roof and the foam dam itself. The foam dam should also incorporate suitable drainage slots to allow rain water and drained out foam to escape. PAGE 3. 18 4023-2-17 ENGINEERING MANUAL SECTION THREE

FOAM INLET PIPEWORK RIMSEAL FOAM POURER RIMSEAL GENERATOR (FITTED INTO FOAM INLET PIPE) SEE FIG 3.12 TANK SHELL FABRIC SEAL SHOE CIRCULAR DAM FLOATING ROOF DRAIN SLOTS Fig 3.15 Typical Foam Dam arrangement for Open Top Floating Roof Tank, showing Rimseal Area, Pourer, Seal & Foam Dam 4023-2-17 ENGINEERING MANUAL SECTION THREE PAGE 3. 19