Steel 45 Fixed Deflection Return R&G (RSAB, RTAB)

Similar documents
Steel and Stainless Steel Perforated Return R&G (RSFA, RTFA, RLFA, RZFA)

Aluminum Perforated Filter Return Grille (RAFM FIlter)

PERFORMANCE DATA 0 and 45 Fixed Deflection Return R&G

Ducted Eggcrate Return Grille (RAPB, RUPB, RATB, RUTB)

INDEX LOUVERS TECHNICAL DATA FROM DOOR PRODUCTS

TWO PERSON WALL MOUNT

AJW. Athletic Series Lockers. Architectural Products ONE TIER TWO TIER THREE TIER FOUR TIER FIVE TIER SIX TIER

cslouvers /CON BuyLine 1006

Awning Windows Premium Atlantic Vinyl

4 Season Enclosure. 3 Season Enclosure. Screen Enclosure. Suggested Installation Instructions. Patio Cover / Car Shield

HINGES & STAYS. Hinges & Stays Large Take-Apart Hinge. Medium Take-Apart Hinge

DOOR - Single Leaf, Premium Duty, Quick-Acting Model 1430 Features 1

AWNINGS Green Design - Add Shade to Save up to 26% on Energy Bills Metal Awnings

250 SERIES 1" STRUCTURAL TUBE MULLION ASSEMBLY INSTRUCTIONS

Seven-eighths-spacing Rackmount Kit/Chassis Rackmount Kit. Techmar enclosure designs include interchangeable modular components,

ULTRA CRADLE. Color Options. Patented design. Allows wine labels to be viewed at an optimal angle. Crafted from lightweight, durable material

A A A T E C H N O L O G Y

Axiom Surface Mounted Headwalls

FIXED WINDOW SECTION DETAILS

8" 9000, " x 25" How to Specify NH-24

The tried-and-tested complete range

Counter Display Items

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

FLUSH MOUNT ALUMINUM DOOR DETAIL (LH SWING)

JOINING MULLION (DIRECT MULL) ASSEMBLY INSTRUCTIONS FOR 3-WAY OR 4-WAY JOINTS FOR IMPERVIA AWNING, CASEMENT AND LARGE AWNING

Louvre Specifications

14522 Naples St Ham Lake, MN fax GUN & PISTOL LOCKERS EVIDENCE LOCKERS PASS THRU DEVICES PERSONNEL LOCKERS

SCREENS TABBED PAGE SCREENS

Closet and Specialty Hardware

SC2000 MASTERSHADE Exterior retractable solar screen systems

The safe & affordable install

PRODUCT INFORMATION MANUAL SECTION: 17 METAL LOUVRE AWNINGS METAL LOUVRE AWNINGS

Levels & Measuring Tools

Big SHOT III Hybridization Oven

TABLE & FURNITURE LEGS

Introduction...COMB-2 Design Considerations and Examples...COMB-3

MODEL CFD Forward Curved Belt Driven Inline Duct Blower

Section 11 Workstation Components

MetroView TM FG 501T Window Wall

Premium - Retractable Stand

Arcade Windows. Architectural Design Manual. July 2014

GRAVITY VENTILATORS SIZING

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

Index. How To Specify TY-CM

Lockable Fasport. IFP-600 Dimensions Overall Height 9.5" Overall Width 10" Opening Dia. 6.5" Weight 9 lbs. Model

Strut Clamp Pipe & Conduit

continuous louvre WALLS

Installation Instructions for the Rolltec Physique XL Awning

Section 17. Flanges & Waveguide. Introduction

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

Hotels Office Space Baths Barn Doors Restaurants Galleries Lofts Kitchens Rustic Homes Closets Recessed Storage

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW

Operation Manual SUPER BEAST Multi-tool SC-11M-10

SECTION 5. Hardware and Optional Accessories for Steel Doors:

Installation Instructions for the Rolltec Bravo Awning

PN 3000 Series Fail Closed Pneumatic Actuators

L&W ENGINEERING INC.

Aviation Snips. Multi-Cable Cutter

WINDOW TECHNOLOGY ORDER CATALOG SECTION Casement & Awning Windows Hardware

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

14522 Naples St Ham Lake, MN fax GUN & PISTOL LOCKERS EVIDENCE LOCKERS PASS THRU DEVICES PERSONNEL LOCKERS

CADDY CORPORATION. Hot Food Caddys

Table and Furniture Base Fittings Furniture Feets

Installation instruction

Installation Instructions for the Rolltec Adalia X3M Extenda Awning

Model Max. Surface m 2 Min. Width mm Max. Width mm Min. Height mm Max. Height mm Solar Guard , ,000

SECTION SPECIFICATIONS PART 1 GENERAL

TensionLite Plus 10 ft. Wave Shape Mural Wall Design 2

Deluxe, heat resistant slide system: Quadro for ovens

apexfacades.com apexfacades.com Printed on 12/12/17

The Next Generation of Textile Duct

WIRING INSTALLATION. Heat Shrink Tubing. Steel Fish Tapes - 1/8'' wide. Fiberglass Fish Tape / (Black) (Asst colors)

TensionLite Plus 10 ft. Wave Shape Mural Wall Design 5

2016 PRODUCTS & PRICES

Formulate 10 Vertical Curve - Kit 5

FILTERED FAN PACKAGES

Bainbridge an uf acturing, Inc.

Formulate 10 Straight - Kit 4

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

Single & double hung hardware

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

* * KR54-F, KR9854 & KR9954 Installation Instructions. Read All Warnings Before Starting Installation! Index:

ADAPTER Adapter for modular suspended ceiling systems

ELITE SERIES R-410A Ready - Multi-Position

continuous louvre WAlls

Product Cut Sheet Z4-SERIES SEISMICFRAME CABINET SYSTEM SERVICE PARTS

Insect Screens. Let the fresh air in

Clarifying the offer for froozen food

Air inlet. 1. Drilled Pipe - Typically drilled pipe uses more compressed air while producing inconsistent flow at high noise levels.

Fiberglass Duct Tools 22\

RK-93S27 RK-93S30 INSTALLATION INSTRUCTIONS BUILT-IN KIT MODELS

FOAM PROPORTIONING EQUIPMENT

Spiral Duct. Contents. Introduction 1. Duct & Fitting Range 2. Duct Sizes 3. Fittings 5. Round Duct Connector 7. Installation 8

Use steel clip angle as a drill template and drill through mullion. Install bolts with bolt heads on the masonry side of the jamb mullion.

CEILING FANS. Included Features

YCW 750 SSG Structural Silicone Glazed Curtain Wall System 4 Side SSG Shop Glazed (2 Side Toggle Glazing Method) Installation Manual

Floor Hatches. Complementary B u i l d i n g Products

Solar Power Shade INSTRUCTION MANUAL

DUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076

Transcription:

Steel 45 Fixed Deflection Return R&G (RSAB, RTAB) 1-1/4 Nom. size +2 2/3 1-3/8 Nom. Size - Nom. Size +2 5/32 Nom. Size - Application: 45 Returns are used primarily as return or exhaust grilles or registers that match the appearance of the supply outlets. They are well suited for locations where the occupant can see into the duct. They can be mounted on the wall or in the ceiling. Standard Features: Steel construction is durable and inexpensive. Teardrop blades are 3/4 deep, on 2/3 centers. Blades can be aligned horizontally or vertically. Deflection is fixed at 45 relative to the air stream. Minimum panel size is 4 x 4. Maximum panel size is 36 x 36. Panels can be joined for larger sizes (p. A311). Register uses Model RXEA opposed blade damper (p. A437). Standard finish is electrocoat acrylic baked enamel. Standard color is #11 bright white. Optional Features: Tamper-proof screws (p. A342). Concealed hangers (p. A343). Pull cord and lever damper operator (p. A343). Debris screen (p. A343). Unit can be set in T-bar panel (Opt. T), and certain sizes can be sheared (Opt. S) to fit T-bar grids (p. A341). Quick Select Chart This shows grilles with: A maximum NC of 35. A minimum duct velocity of 300 FPM. CFM 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 1400 1450 1500 1550 1600 1650 Size Area 8 x 4 0.22 10 x 4 0.28 8 x 6 0.33 10 x 6 0.42 12 x 6 0.50 16 x 6 0.67 20 x 6 0.83 24 x 6 1.00 24 x 8 1.33 24 x 10 1.67 (75-275) (85-295) (100-340) (130-440) (150-475) (210-620) (250-695) (300-800) (410-1050) (470-1165) Model Numbering System OPTIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 R S A B H 0 0 4 0 0 4 0 1 1 R - Register or Grille S - Steel Grille T - Steel Register DESIGN SERIES A - 45 Fixed Deflection Return FRONT BLADE ALIGNMENT H - Horizontal (Blades Parallel to Width) V - Vertical (Blades Parallel to Height) WIDTH 004-4 Minimum HEIGHT 004-4 Minimum FRACTIONAL SIZE 0-0 1-1/8 2-1/4 3-3/8 4-5 - 5/8 6-3/4 7-7/8 FINISH 11 - Bright White (Default) 01 - Off-White 04 - Gray ADD ONS G - Gasket F - Fusible Link Q - Gasket & Fusible Link 1 - Debris Screen 2 - Gasket & Debris Screen 3 - Gasket, Debris Screen & Fusible Link 4 - Fusible Link & Debris Screen DAMPER OPERATOR X - Std. Operator (Default) P - Pull Cord Ceiling A - Pull Cord Wall V - Lever MOUNTING Y - Std. Screws (Default) N - No Screw Holes S - Sheared Frame for T-bar B - Tamper-proof Screws U - W-clips for Snap-in Ceiling C - Concealed Hangers Z - Z-clips for Spline Ceiling T - Panel: 24 x24 T-bar Ceiling www.carnes.com A-273

PERFORMANCE DATA 0 and 45 Fixed Deflection Return R&G Steel 0 (RSRB, RTRB) Aluminum 0 (RARM, RNRM) Stainless Steel 0 (RLRB, RMRB, RKRB) Steel 45 (RSAB, RTAB) Aluminum 45 (RAAM, RNAM) Stainless Steel 45 (RLAB, RMAB, RKAB) Correction Factors for Grille Performance Total Pressure (Pt) For a 0 deflection grille, use the data unchanged from the table. For a 45 deflection grille, multiply the table data by 1.8. Sound Level (NC) For a 0 deflection grille, use the table data unchanged. For a 45 deflection grille, add 5db to the table data. Correction Factors for Register Performance Total Pressure (Pt) For a 0 deflection register with a wide open damper, multiply the table data by 1.2. For a 45 deflection register with a wide open damper, multiply the table data by 2.0. Sound Level (NC) For a 0 deflection register with a wide open damper, add 2db to the table data. For a 45 deflection register with a wide open damper, add 7db to the table data. Duct Velocity (fpm) 200 400 600 800 1000 Total Pressure (w. g.) 0.020 0.050 0.090 0.140 0.200 4x4 Flow (CFM) 22 44 66 88 110 (.11 ft 2 ) Sound (NC) 6x6 Flow (CFM) 50 100 150 200 250 (.25 ft 2 ) Sound (NC) 21 8x6 Flow (CFM) 65 130 200 270 340 (.33 ft 2 ) Sound (NC) 24 10x6 Flow (CFM) 80 160 240 320 400 (.42 ft 2 ) Sound (NC) 20 26 12x6 Flow (CFM) 90 180 260 350 440 (.50 ft 2 ) Sound (NC) 21 27 14x6 Flow (CFM) 110 220 330 440 550 (.58 ft 2 ) Sound (NC) 23 29 12x8 Flow (CFM) 140 280 400 550 690 (.67 ft 2 ) Sound (NC) 25 32 12x10 Flow (CFM) 160 320 480 640 800 (.83 ft 2 ) Sound (NC) 26 33 12x12 Flow (CFM) 200 400 600 800 1000 (1.00 ft 2 ) Sound (NC) 21 29 35 14x14 Flow (CFM) 270 540 820 1090 1360 (1.36 ft 2 ) Sound (NC) 23 31 37 18x12 Flow (CFM) 310 620 930 1240 1550 (1.50 ft 2 ) Sound (NC) 24 32 39 16x16 Flow (CFM) 360 710 1070 1420 1780 (1.77 ft 2 ) Sound (NC) 26 34 41 Performance Data Sound values are given in NC, are based on a room absorption of 10db re 10-12 watts. Pressure values are given in inches of water. Flow values are given in cubic feet per minute. Actual performance in the field may vary. www.carnes.com A-275

PERFORMANCE DATA 0 and 45 Fixed Deflection Return R&G Steel 0 (RSRB, RTRB) Aluminum 0 (RARM, RNRM) Stainless Steel 0 (RLRB, RMRB, RKRB) Steel 45 (RSAB, RTAB) Aluminum 45 (RAAM, RNAM) Stainless Steel 45 (RLAB, RMAB, RKAB) Duct Velocity (fpm) 200 400 600 800 1000 Total Pressure (w. g.) 0.020 0.050 0.090 0.140 0.200 18x16, 24x12 Flow (CFM) 400 800 1200 1600 2000 (2.00 ft 2 ) Sound (NC) 27 35 42 18x18 Flow (CFM) 450 900 1200 1800 2200 (2.25 ft 2 ) Sound (NC) 28 36 43 36x12, 24x18 Flow (CFM) 600 1200 1800 2400 3000 (3.00 ft 2 ) Sound (NC) 30 39 45 24x24 Flow (CFM) 800 1600 2400 3200 4000 (4.00 ft 2 ) Sound (NC) 21 33 42 48 36x18 Flow (CFM) 900 1800 2700 3600 4500 (4.50 ft 2 ) Sound (NC) 22 34 43 49 30x24, 36x20 Flow (CFM) 1000 2000 3000 4000 5000 (5.00 ft 2 ) Sound (NC) 23 35 44 50 36x24, 48x18 Flow (CFM) 1200 2400 3600 4800 6000 (6.00 ft 2 ) Sound (NC) 24 36 45 52 36x36 Flow (CFM) 1800 3600 5400 7200 9000 (9.00 ft 2 ) Sound (NC) 29 41 49 56 40x36 Flow (CFM) 2000 4000 6000 8000 10000 (10.00 ft 2 ) Sound (NC) 30 42 50 57 44x36 Flow (CFM) 2200 4400 6600 8800 11000 (11.00 ft 2 ) Sound (NC) 31 43 52 59 48x36 Flow (CFM) 2400 4800 7200 9600 12000 (12.00 ft 2 ) Sound (NC) 33 45 54 61 Performance Data Sound values are given in NC, are based on a room absorption of 10db re 10-12 watts. Pressure values are given in inches of water. Flow values are given in cubic feet per minute. Actual performance in the field may vary. A-276 www.carnes.com

Multi-Panel Construction Multi-Panel Construction for the following Registers & Grilles Steel Stainless Steel Aluminum Single Deflection RSSB, RTSB RLSB, RMSB, RKSB RASM, RNSM Double Deflection RSDB, RTDB RLDB, RMDB, RKDB RADM, RNDM 0 Fixed Return RSRB, RTRB RLRB, RMRB, RKRB RARM, RNRM 45 Fixed Return RSAB, RTAB RLAB, RMAB, RKAB RAAM, RNAM In-line Construction W: Over 72 W: 38-72 H: Up to 36 H: Up to 36 Height: Up to 36 Width: 38 to 72 Two sections. Any blade alignment. Height: Up to 36 Width: Over 72 Three or more sections. Any blade alignment. Height: 38-72 Width: Up to 36 Any blade alignment Height: Over 72 Width: Up to 36 Three or More Sections Any blade alignment W: Up to 36 (13) 1/4 (6) W: Up to 36 1. Maximum single panel width and height is 36 listed size regardless of blade alignment. 2. Panels are made in even inch increments unless specified otherwise. 3. Front blade alignment is as pictured. 4. Grille height & width dimensions shown are listed size dimensions. 5. Panel flanges are sheared and aligned with joining strips. H: 38 72 H: Over 72 Ganged Construction 1. Maximum single panel width is 36 listed size. 2. Maximum single panel height is 36 listed size. 3. Panels will be made in even inch increments unless specified otherwise. 4. Front blade alignment is always parallel to center support. 5. Either the vertical or horizontal joint can be sheared down, but not both. 6. The center support can be aligned vertically or horizontally, depending on blade alignment desired. It is shown here mounted horizontally. 7. Grille height and width dimensions shown are listed size dimensions. 8. Metric dimensions are shown in millimeters. Duct Height Duct Width W: 38-72 Center Support installs flush with wall Wall Angle Center Support Attachment to Wall Opening Wall 2-3/8 (60) Cross-Sectional View of Center Support with Grilles Attached (13) 1/4 (6) H: 38-74 1/2 (13) 2- (64) 1-1/4 (32) 2 (51) www.carnes.com A-299

Multi-Panel Construction Multi-Panel Construction for the following Registers & Grilles Louvered Return Perforated Return In-Line Construction Steel RSLA, RTLA RSFA, RTFA Height: Up to 36 Height: Up to 48 Width: Over 96 Width: Over 72 Horizontal Blade Alignment Vertical Blade Alignment Three or More Sections Three or More Sections W Height: 38-72 Width: Up to 48 Horizontal Blade Alignment W Height: Over 72 Width: Up to 48 Horizontal Blade Alignment Three or More Sections W W H H H Height: Up to 36 Height: Up to 48 Width: 50 to 96 Width: 38 to 72 Horizontal Blade Alignment Vertical Blade Alignment H (13) 1/4 (6) Height: 50-96 Width: Up to 36 Vertical Blade Alignment Ganged Construction 1. Either the vertical or horizontal joint can be sheared down, but not both. 2. Maximum single panel width is 48 listed size. 3. Maximum blade length on louvered face models is listed size 48. 4. Maximum single panel height is 36 listed size. 5. Panels are made in even inch increments unless specified otherwise. 6. Blade alignment is always parallel to center support. 7. The center support can be aligned vertically or horizontally, depending on the blade alignment desired. It is shown here mounted horizontally. 8. Grille dimensions shown are listed size dimensions. (13) 1/4 (6) Height: Over 96 Width: Up to 36 Vertical Blade Alignment Three or more Sections Duct Height H: 38-74 1. Panels will be made in even inch increments unless specified otherwise. 2. Dimensions shown are listed size dimensions. 3. Max. blade length on louvered face models is nominal 48. 4. Panels are sheared and aligned with joining strips. Duct Width W: 50-96 Center Support install flush with wall Wall Angle Center Support Attachment to Wall Opening Wall Cross-Sectional View of Center Support with Grilles Attached 1/2 (13) 2- (64) 1-1/4 (32) 2-3/8 (60) A-300 www.carnes.com 2 (51)

Multi-Panel In-Line & Ganged Construction Multi-Panel In-Line Construction 1. Maximum single panel width and height is 48 nominal size, regardless of blade alignment. 2. Panels are made in even inch increments unless specified otherwise. 3. Front blade alignment is as pictured. 4. Grille dimensions shown are nominal dimensions. 5. Panel flanges are sheared and aligned with joining strips. Height: 50-96 Width: Up to 48 Any Blade Alignment H (50-96 ) W (Up to 48 ) Height: Up to 48 Width: 50-96 (Two Sections) Any Blade Alignment 1/4 Height: Up to 48 Width: Over 96 Three or more Sections Any Blade Alignment Height: Over 96 Width: Up to 48 Three or more Sections Any Blade Alignment W (Up to 48 ) W (50-96 ) W (Over 96 ) H: (Up to 48 ) H: (Up to 48 ) Multi-Panel Ganged Construction 1. Maximum single panel width and height are 48 nominal size. 2. Panels are made in even inch increments unless specified otherwise. 3. Front blade alignment is always parallel to center support. 4. Either the vertical or horizontal joint can be sheared down, but not both. 5. The center support can be aligned vertically or horizontally, depending on blade alignment desired. 6. Grille dimensions shown are nominal dimensions. W: 50-96 Cross-Sectional View of Center Support H: (50-98) 2-1-1/4 (13) Duct Height 2 Duct Width 1/4 2-3/8 (60) Center Support installs flush with wall Wall Angle Wall Center Support Mounted flush with wall (Shown aligned horizontally). www.carnes.com A-301

Multi-Panel Construction for M-Series Alum. R&G All Sections of Butted Grilles or Registers will be made in Listed Sizes as Standard. STANDARD REGISTERS AND GRILLES Applies to all models except louvered return air registers and grilles and door partition grilles. Registers and grilles over 36 x 36 butting two or more grilles together. GRILLES AND REGISTERS HAVING FOUR SECTIONS AND OVER NOTES: Extruded aluminum supporting members with mounting angles, are furnished where required. Center support may run vertically or horizontally, depending upon combination of grilles used. Combination of panels will be furnished to fit duct opening with satisfactory clearance. A-302 www.carnes.com

Screw Hole Locations Screw Hole Location for the following Registers & Grilles Steel Aluminum Stainless Steel Single Deflection RSSB, RTSB RASM, RNSM RLSB, RMSB, RKSB Double Deflection RSDB, RTDB RADM, RNDM RLDB, RMDB, RKDB 0 Fixed Return RSRB, RTRB RARM, RNRM RLRB, RMRB, RKRB 45 Fixed Return RSAB, RTAB RAAM, RNAM RLAB, RMAB, RKAB Louvered Return RSLA, RTLA Perforated Return RSFA, RTFA RAFM, RNFM Screw holes on the face are standard on Registers and Grilles. Steel R&G can be ordered without screw holes, for use with concealed hangers (Opt. N). The screw holes is 5/32 in diameter. Each Register or Grille is provided with the appropriate number of screws as standard. The standard screw is #8 x 1-1/4 pan head screw, with a flat blade head. Tamper-proof screws are available as an option (Opt. B). Nominal Size Plus 2 1/2 Nominal +1 One Screw hole per Side Nominal Size Range 4 through 18. Nominal Size +2 6 6 Two Screw holes per Side Nominal Size Range 19 through 31. 1/2 Nominal +1 Nominal Size +2 6 6 Three Screw holes per Side Nominal Size Range 32 through 48. www.carnes.com A-303