P.O. Box 309 Menomonee Falls, WI 5305-0309 800 BRADLEY + 6-5-6000 bradleycorp.com Equa-Flo Shower Valve, Version Prior to March, 00 For Individual, Econo-Walls, Wall Savers, Panelons and olumn Showers NOTE: Should the rotor come off the stem, align groove in outer rim of rotor with groove in spline on the stem when reassembling. Also, if you should wish to reverse hot for cold and cold for hot due to install error, or back to back installation, you can reassemble rotor 80 against stem and valve will work properly. olumn Type Showers Wall Type Showers 300-39 (Individual) 300-7 (Wall Saver) 300-38 (Panelon & Econowall) 3 0 3 5 6 Escutcheon Screws: () 60-78 7 9 8 0 3 5 7 6 8 Escutcheon Screws () 60-78 9 50-093 (6 person) 50-09 (-5 person) (NOTE: These parts have a satin finish with etched lettering) Valves are equipped with a temperature limit which can be used to limit the temperature of tempered water discharged. To adjust the temperature, remove the handle and loosen the set screw. remove the limit and reposition to desired setting. Turn the limit counterclockwise for a hotter setting and clockwise for a cooler setting. Equa-Flo Shower Valve PRIOR to March, 00 Note: When replacing the double face seals, lubricate the top face with a small amount of lubricant reassembling. When assembling cap into valve body, use lubricant on 69-03 O-ring to prevent twisting of O-ring. If lubricant is not available, a slight film of soap may be used. of 5 9/3/0 Bradley 5-369-5 Rev. F: EN -03-03
P.O. Box 309 Menomonee Falls, WI 5305-0309 800 BRADLEY + 6-5-6000 bradleycorp.com Equa-Flo Shower Valve Parts List, Version Prior to March, 00 (Figure 0) Item Part No. Description Assembly atridge Assembly S67-359 Qty Stem Assembly S-065 Gasket Repair Kit S65-073 5-055 Square Ring (In Rear) S55-009 Sleeve & Flapper (Ear must fit into groove) 3 8-5 artridge ousing 5-08 Double-face Seal 5 0-0 Rotor 6 0-33 Stem 7 35-08 Spring 8 5-053 Washer 9 5-00B O-Ring 0 69-03 O-Ring 07-80 ap/lamp 60- Screws 3 07-79 over 5-00Y O-Ring 5-0 OFF Stop 6-033 ot Stop 7 60-5 Set Screw 8 8-07 andle 9 60- Screw 0 5-00BS Gasket 8-3 Valve Body 69-69 Top Seat Gasket 3 69-56 Screws 73-05 Screens (Internal) 5 S7-0 Stops (Optional) omplete olumn Valve Replacement for olumns Built Prior to March, 00: S65-075 for -5 Person S65-076 for 6-Person Equa-Flow Shower Valve PRIOR to March, 00 of 5 9/3/0 Bradley 5-369-5 Rev. F: EN -03-03
P.O. Box 309 Menomonee Falls, WI 5305-0309 800 BRADLEY + 6-5-6000 bradleycorp.com Equa-Flo Shower Valve, March, 00 to July, 00 (Figure 0) For Individual, Econo-Walls, Wall Savers, Panelons and olumn Showers NOTE: Should the rotor come off the stem, align groove in outer rim of rotor with groove in spine on the stem when reassembling. Also, if you should wish to reverse hot for cold and cold for hot due to install error, or back to back installation, you can reassemble rotor 80 against stem and valve will work properly. olumn Type Showers Wall Type Showers 300-0 (Individual & Econowall) 300- (Panelon) 300-7 (Wall Saver) 3 0 3 5 6 Escutcheon Screws: () 60-7 Figure 0a 9 8 0 3 5 7 6 8 Escutcheon Screws () 60-78 9 50-06 (6 person) 50-05 (-5 person) (NOTE: These parts have a chrome finish with cast-in recessed lettering) Valves are equipped with a temperature limit which can be used to limit the temperature of tempered water discharged. To adjust the temperature, remove the handle and loosen the set screw. remove the limit and reposition to desired setting. Turn the limit counterclockwise for a hotter setting and clockwise for a cooler setting. Equa-Flo Shower Valve March, 00 to July, 00 Note: When replacing the double face seals, lubricate the top face with a small amount of lubricant reassembling. When assembling cap into valve body, use lubricant on 69-03 O-ring to prevent twisting of O-ring. If lubricant is not available, a slight film of soap may be used. 3 of 5 9/3/0 Bradley 5-369-5 Rev. F: EN -03-03
P.O. Box 309 Menomonee Falls, WI 5305-0309 800 BRADLEY + 6-5-6000 bradleycorp.com Equa-Flo Shower Valve Parts List, March, 00 to July, 00 (Figure 0) Item Part No. Description Assembly atridge Assembly S67-359 Qty Stem Assembly S-065 Gasket Repair Kit S65-073 5-055 Square Ring (In Rear) S55-009 Sleeve & Flapper (Ear must fit into groove) 3 8-5 artridge ousing 5-08 Double-face Seal 5 0-0 Rotor 6 0-33 Stem 7 35-08 Spring 8 5-053 Washer 9 5-00B O-Ring 0 69-03 O-Ring 07-80 ap/lamp 60- Screws 3 07-79 over 5-00Y O-Ring 5-0 OFF Stop 6-033 ot Stop 7 60-5 Set Screw 8 8-07 andle 9 60- Screw 0 5-00BS Gasket 8-3 Valve Body 69-69 Top Seat Gasket 3 69-56 Screws 73-05 Screens (Internal) 5 S7-0 Stops (Optional) omplete olumn Valve Replacement for olumns Built March, 00 to July, 00: S65-35 for -5 Person S65-36 for 6-Person Equa-Flow Shower Valve March, 00 to July, 00 of 5 9/3/0 Bradley 5-369-5 Rev. F: EN -03-03
Adjusting the Equa-Flo Valve Operation and Service Guide: Showers P.O. Box 309 Menomonee Falls, WI 5305-0309 800 BRADLEY + 6-5-6000 bradleycorp.com NOTE: The maximum temperature limit has been preset by the factory for maximum temperature operation. For temperatures other than the maximum, the may be repositioned as shown below. IMPORTANT: Failure to adjust the maximum temperature limit to a safe shower temperature, no more than 05 F, could result in the user being scalded.. Loosen the setscrew in the bottom of the hot limit.. Remove the outer most and reposition to the desired temperature setting. NOTE: Do not remove the inner off-. A. Position the Temperature Stops as shown for Individual Wall Showers. B. Position the Temperature Stops as shown for Wall-Savers, Panelons and Econo-Walls.. Position the Temperature Stops as shown for olumn Showers. 3. If the desired position falls between adjacent positions on the spline, flip the over so that the other face shows. This shifts the position by / spline. FOR BAK-TO-BAK INSTALLATION: On the valve that is installed "backwards," rotate the stem 80 so that the "groove in spline" is opposite that shown for tub and shower valves. ESUTEON TO SOWEREAD 5 8 9 FOR BAK-TO-BAK INSTALLATION ONLY (GROOVE IN SPLINE) 7 6 TUB & SOWER VALVES WALL-SAVER VALVES 5 of 5 9/3/0 Bradley 5-369-5 Rev. F: EN -03-03